JNX-OPT-IF-MIB
Updated Aug 13, 2003The MIB module to describe pre-OTN and OTN interfaces. Copyright (C) The Internet Society (2003). This version of this MIB module is part of RFC 3591; see the RFC itself for full legal notices.
Main OID:
jnxoptIfMibModule.1.3.6.1.4.1.2636.3.73.1
430
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
430 total| Object Name |
|---|
jnxoptIfMibModuleThe MIB module to describe pre-OTN and OTN interfaces.
Copyright (C) The Internet Society (2003). This version
of this MIB module is part of RFC 3591; see the RFC
itself for full legal notices. MODULE-IDENTITY .1.3.6.1.4.1.2636.3.73.1 |
jnxoptIfObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1 |
jnxoptIfOTMn OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.1 |
jnxoptIfOTMnTableA table of OTMn structure information. SEQUENCE OF JnxoptIfOTMnEntry .1.3.6.1.4.1.2636.3.73.1.1.1.1 |
jnxoptIfOTMnEntryA conceptual row that contains the OTMn structure
information of an optical interface. JnxoptIfOTMnEntry .1.3.6.1.4.1.2636.3.73.1.1.1.1.1 |
jnxoptIfOTMnOrderThis object indicates the order of the OTM, which
represents the maximum number of wavelengths that can be
supported at the bit rate(s) supported on the interface.ro Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.1.1.1.1 |
jnxoptIfOTMnReducedThis object indicates whether a reduced or full
functionality is supported at the interface. A value of
true means reduced. A value of false means full.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.1.1.1.2 |
jnxoptIfOTMnBitRatesThis attribute is a bit map representing the bit
rate or set of bit rates supported on the interface.
The meaning of each bit position is as follows:
bitRateK1(0) is set if the 2.5 Gbit/s rate is supported
bitRateK2(1) is set if the 10 Gbit/s rate is supported
bitRateK3(2) is set if the 40 Gbit/s rate is supported
Note that each bit position corresponds to one possible
value of the type JnxoptIfBitRateK.
The default value of this attribute is system specific.ro Bits .1.3.6.1.4.1.2636.3.73.1.1.1.1.1.3 |
jnxoptIfOTMnInterfaceTypeThis object identifies the type of interface. The value of
this attribute will affect the behavior of the OTM with
respect to presence/absence of OTM Overhead Signal (OOS)
processing and TCM activation. For an IrDI interface,
there is no OOS processing and TCM activation is limited
to n levels as specified by a TCM level threshold.
This object contains two fields that are separated by
whitespace. The possible values are:
field 1: one of the 4-character ASCII strings
'IrDI' or 'IaDI'
field 2: free-form text consisting of printable
UTF-8 encoded characters
Note that field 2 is optional. If it is not present then there
is no requirement for trailing whitespace after field 1.
The default values are as follows:
field 1: 'IaDI' field 2: an empty string.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2636.3.73.1.1.1.1.1.4 |
jnxoptIfOTMnTcmMaxThis object identifies the maximum number of TCM
levels allowed for any Optical Channel contained
in this OTM. A new TCM activation will be rejected
if the requested level is greater than the threshold.
If InterfaceType object specifies a type of 'IaDI'
for this OTM, then this attribute is irrelevant.
Possible values: unsigned integers in the range
from 0 to 6 inclusive.
Default value: 3.rw Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.1.1.1.5 |
jnxoptIfOTMnOpticalReachThis object indicates the length the optical signal
may travel before requiring termination or regeneration.
The meaning of the enumeration are:
intraOffice(1) - intra-office (as defined in ITU-T G.957)
shortHaul(2) - short haul (as defined in ITU-T G.957)
longHaul(3) - long haul (as defined in ITU-T G.957)
veryLongHaul(4) - very long haul (as defined in ITU-T G.691)
ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691)ro Enumeration .1.3.6.1.4.1.2636.3.73.1.1.1.1.1.6 |
jnxoptIfPerfMon OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.2 |
jnxoptIfPerfMonIntervalTableA table of 15-minute performance monitoring interval
information. SEQUENCE OF JnxoptIfPerfMonIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.2.1 |
jnxoptIfPerfMonIntervalEntryA conceptual row that contains 15-minute performance
monitoring interval information of an interface. JnxoptIfPerfMonIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.2.1.1 |
jnxoptIfPerfMonCurrentTimeElapsedNumber of seconds elapsed in the current 15-minute
performance monitoring interval.
If, for some reason, such as an adjustment in the NE's
time-of-day clock, the number of seconds elapsed exceeds
the maximum value, then the maximum value will be returned.ro Gauge32 .1.3.6.1.4.1.2636.3.73.1.1.2.1.1.1 |
jnxoptIfPerfMonCurDayTimeElapsedNumber of seconds elapsed in the current 24-hour interval
performance monitoring period.
If, for some reason, such as an adjustment in the NE
time-of-day clock, the number of seconds elapsed exceeds
the maximum value, then the maximum value will be returned.ro Gauge32 .1.3.6.1.4.1.2636.3.73.1.1.2.1.1.2 |
jnxoptIfPerfMonIntervalNumIntervalsThe number of 15-minute intervals for which performance
monitoring data is available. The number is the same for all
the associated sub layers of the interface.
An optical interface must be capable of supporting at least
n intervals, where n is defined as follows:
The minimum value of n is 4.
The default of n is 32.
The maximum value of n is 96.
The value of this object will be n unless performance
monitoring was (re-)started for the interface within the last
(n*15) minutes, in which case the value will be the number of
complete 15-minute intervals since measurement was
(re-)started.ro Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.2.1.1.3 |
jnxoptIfPerfMonIntervalNumInvalidIntervalsThe number of intervals in the range from 0 to
jnxoptIfPerfMonIntervalNumIntervals for which no performance
monitoring data is available and/or the data is invalid.ro Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.2.1.1.4 |
jnxoptIfOTSn OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.3 |
jnxoptIfOTSnConfigTableA table of OTSn configuration information. SEQUENCE OF JnxoptIfOTSnConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.3.1 |
jnxoptIfOTSnConfigEntryA conceptual row that contains OTSn configuration
information of an interface. JnxoptIfOTSnConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.3.1.1 |
jnxoptIfOTSnDirectionalityIndicates the directionality of the entity.ro JnxoptIfDirectionality .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.1 |
jnxoptIfOTSnAprStatusThis attribute indicates the status of the Automatic
Power Reduction (APR) function of the entity. Valid
values are 'on' and 'off'.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.2 |
jnxoptIfOTSnAprControlThis object is a UTF-8 encoded string that specifies Automatic
Power Reduction (APR) control actions requested of this entity
(when written) and that returns the current APR control state
of this entity (when read). The values are implementation-defined.
Any implementation that instantiates this object must document the
set of values that it allows to be written, the set of values
that it will return, and what each of those values means.rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.3 |
jnxoptIfOTSnTraceIdentifierTransmittedThe trace identifier transmitted.
This object is applicable when jnxoptIfOTSnDirectionality has the
value source(2) or bidirectional(3).
This object does not apply to reduced-capability systems (i.e.,
those for which jnxoptIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1
has the value 'IrDI').
If no value is ever set by a management entity for the object
jnxoptIfOTSnTraceIdentifierTransmitted, system-specific default
value will be used. Any implementation that instantiates this
object must document the system-specific default value or how it
is derived.rw JnxoptIfTxTI .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.4 |
jnxoptIfOTSnDAPIExpectedThe DAPI expected by the receiver.
This object is applicable when jnxoptIfOTSnDirectionality has the
value sink(1) or bidirectional(3). It has no effect if
jnxoptIfOTSnTIMDetMode has the value off(1) or sapi(3).
This object does not apply to reduced-capability systems (i.e.,
those for which jnxoptIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1
has the value 'IrDI').rw JnxoptIfExDAPI .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.5 |
jnxoptIfOTSnSAPIExpectedThe SAPI expected by the receiver.
This object is applicable when jnxoptIfOTSnDirectionality has the
value sink(1) or bidirectional(3). It has no effect if
jnxoptIfOTSnTIMDetMode has the value off(1) or dapi(2).
This object does not apply to reduced-capability systems (i.e.,
those for which jnxoptIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1
has the value 'IrDI').rw JnxoptIfExSAPI .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.6 |
jnxoptIfOTSnTraceIdentifierAcceptedThe actual trace identifier received.
This object is applicable when jnxoptIfOTSnDirectionality has the
value sink(1) or bidirectional(3). Its value is unspecified
if jnxoptIfOTSnCurrentStatus has either or both of the
losO(5) and los(6) bits set.
This object does not apply to reduced-capability systems (i.e.,
those for which jnxoptIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1
has the value 'IrDI').ro JnxoptIfAcTI .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.7 |
jnxoptIfOTSnTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function. This object is applicable
when jnxoptIfOTSnDirectionality has the value sink(1)
or bidirectional(3). The default value is off(1).
This object does not apply to reduced-capability systems (i.e.,
those for which jnxoptIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1
has the value 'IrDI').
The default value of this object is off(1).rw JnxoptIfTIMDetMode .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.8 |
jnxoptIfOTSnTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled. This object
is applicable when jnxoptIfOTSnDirectionality has the
value sink(1) or bidirectional(3). It has no effect
when the value of jnxoptIfOTSnTIMDetMode is off(1).
This object does not apply to reduced-capability systems (i.e.,
those for which jnxoptIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1
has the value 'IrDI').
The default value of this object is false(2).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.9 |
jnxoptIfOTSnCurrentStatusIndicates the defect condition of the entity, if any.
This object is applicable when jnxoptIfOTSnDirectionality
has the value sink(1) or bidirectional(3). In
reduced-capability systems or at IrDI interfaces
the only bit position that may be set is los(6).ro Bits .1.3.6.1.4.1.2636.3.73.1.1.3.1.1.10 |
jnxoptIfOTSnSinkCurrentTableA table of OTSn sink performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOTSnSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.3.2 |
jnxoptIfOTSnSinkCurrentEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface for the current
15-minute interval. JnxoptIfOTSnSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.3.2.1 |
jnxoptIfOTSnSinkCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.1 |
jnxoptIfOTSnSinkCurrentInputPowerThe optical power monitored at the input.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.2 |
jnxoptIfOTSnSinkCurrentLowInputPowerThe lowest optical power monitored at the input during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.3 |
jnxoptIfOTSnSinkCurrentHighInputPowerThe highest optical power monitored at the input during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.4 |
jnxoptIfOTSnSinkCurrentLowerInputPowerThresholdThe lower limit threshold on input power. If
jnxoptIfOTSnSinkCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.5 |
jnxoptIfOTSnSinkCurrentUpperInputPowerThresholdThe upper limit threshold on input power. If
jnxoptIfOTSnSinkCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.6 |
jnxoptIfOTSnSinkCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.7 |
jnxoptIfOTSnSinkCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.8 |
jnxoptIfOTSnSinkCurrentHighOutputPowerThe highest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.9 |
jnxoptIfOTSnSinkCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
jnxoptIfOTSnSinkCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.10 |
jnxoptIfOTSnSinkCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
jnxoptIfOTSnSinkCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.2.1.11 |
jnxoptIfOTSnSinkIntervalTableA table of historical OTSn sink performance monitoring
information. SEQUENCE OF JnxoptIfOTSnSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.3.3 |
jnxoptIfOTSnSinkIntervalEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOTSnSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.3.3.1 |
jnxoptIfOTSnSinkIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.1 |
jnxoptIfOTSnSinkIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.2 |
jnxoptIfOTSnSinkIntervalLastInputPowerThe last optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.3 |
jnxoptIfOTSnSinkIntervalLowInputPowerThe lowest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.4 |
jnxoptIfOTSnSinkIntervalHighInputPowerThe highest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.5 |
jnxoptIfOTSnSinkIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.6 |
jnxoptIfOTSnSinkIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.7 |
jnxoptIfOTSnSinkIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.3.1.8 |
jnxoptIfOTSnSinkCurDayTableA table of OTSn sink performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOTSnSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.4 |
jnxoptIfOTSnSinkCurDayEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOTSnSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.4.1 |
jnxoptIfOTSnSinkCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.4.1.1 |
jnxoptIfOTSnSinkCurDayLowInputPowerThe lowest optical power monitored at the input during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.4.1.2 |
jnxoptIfOTSnSinkCurDayHighInputPowerThe highest optical power monitored at the input during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.4.1.3 |
jnxoptIfOTSnSinkCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.4.1.4 |
jnxoptIfOTSnSinkCurDayHighOutputPowerThe highest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.4.1.5 |
jnxoptIfOTSnSinkPrevDayTableA table of OTSn sink performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOTSnSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.5 |
jnxoptIfOTSnSinkPrevDayEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOTSnSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.5.1 |
jnxoptIfOTSnSinkPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.5.1.1 |
jnxoptIfOTSnSinkPrevDayLastInputPowerThe last optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.5.1.2 |
jnxoptIfOTSnSinkPrevDayLowInputPowerThe lowest optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.5.1.3 |
jnxoptIfOTSnSinkPrevDayHighInputPowerThe highest optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.5.1.4 |
jnxoptIfOTSnSinkPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.5.1.5 |
jnxoptIfOTSnSinkPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.5.1.6 |
jnxoptIfOTSnSinkPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.5.1.7 |
jnxoptIfOTSnSrcCurrentTableA table of OTSn source performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOTSnSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.3.6 |
jnxoptIfOTSnSrcCurrentEntryA conceptual row that contains OTSn source performance
monitoring information of an interface for the current
15-minute interval. JnxoptIfOTSnSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.3.6.1 |
jnxoptIfOTSnSrcCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.1 |
jnxoptIfOTSnSrcCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.2 |
jnxoptIfOTSnSrcCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.3 |
jnxoptIfOTSnSrcCurrentHighOutputPowerThe highest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.4 |
jnxoptIfOTSnSrcCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
jnxoptIfOTSnSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.5 |
jnxoptIfOTSnSrcCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
jnxoptIfOTSnSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.6 |
jnxoptIfOTSnSrcCurrentInputPowerThe optical power monitored at the input.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.7 |
jnxoptIfOTSnSrcCurrentLowInputPowerThe lowest optical power monitored at the input during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.8 |
jnxoptIfOTSnSrcCurrentHighInputPowerThe highest optical power monitored at the input during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.9 |
jnxoptIfOTSnSrcCurrentLowerInputPowerThresholdThe lower limit threshold on input power. If
jnxoptIfOTSnSrcCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.10 |
jnxoptIfOTSnSrcCurrentUpperInputPowerThresholdThe upper limit threshold on input power. If
jnxoptIfOTSnSrcCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.6.1.11 |
jnxoptIfOTSnSrcIntervalTableA table of historical OTSn source performance monitoring
information. SEQUENCE OF JnxoptIfOTSnSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.3.7 |
jnxoptIfOTSnSrcIntervalEntryA conceptual row that contains OTSn source performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOTSnSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.3.7.1 |
jnxoptIfOTSnSrcIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.1 |
jnxoptIfOTSnSrcIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.2 |
jnxoptIfOTSnSrcIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.3 |
jnxoptIfOTSnSrcIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.4 |
jnxoptIfOTSnSrcIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.5 |
jnxoptIfOTSnSrcIntervalLastInputPowerThe last optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.6 |
jnxoptIfOTSnSrcIntervalLowInputPowerThe lowest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.7 |
jnxoptIfOTSnSrcIntervalHighInputPowerThe highest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.7.1.8 |
jnxoptIfOTSnSrcCurDayTableA table of OTSn source performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOTSnSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.8 |
jnxoptIfOTSnSrcCurDayEntryA conceptual row that contains OTSn source performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOTSnSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.8.1 |
jnxoptIfOTSnSrcCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.8.1.1 |
jnxoptIfOTSnSrcCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.8.1.2 |
jnxoptIfOTSnSrcCurDayHighOutputPowerThe highest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.8.1.3 |
jnxoptIfOTSnSrcCurDayLowInputPowerThe lowest optical power monitored at the input during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.8.1.4 |
jnxoptIfOTSnSrcCurDayHighInputPowerThe highest optical power monitored at the input during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.8.1.5 |
jnxoptIfOTSnSrcPrevDayTableA table of OTSn source performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOTSnSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.9 |
jnxoptIfOTSnSrcPrevDayEntryA conceptual row that contains OTSn source performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOTSnSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.3.9.1 |
jnxoptIfOTSnSrcPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.3.9.1.1 |
jnxoptIfOTSnSrcPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.9.1.2 |
jnxoptIfOTSnSrcPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.9.1.3 |
jnxoptIfOTSnSrcPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.9.1.4 |
jnxoptIfOTSnSrcPrevDayLastInputPowerThe last optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.9.1.5 |
jnxoptIfOTSnSrcPrevDayLowInputPowerThe lowest optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.9.1.6 |
jnxoptIfOTSnSrcPrevDayHighInputPowerThe highest optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.3.9.1.7 |
jnxoptIfOMSn OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.4 |
jnxoptIfOMSnConfigTableA table of OMSn configuration information. SEQUENCE OF JnxoptIfOMSnConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.4.1 |
jnxoptIfOMSnConfigEntryA conceptual row that contains OMSn configuration
information of an interface. JnxoptIfOMSnConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.4.1.1 |
jnxoptIfOMSnDirectionalityIndicates the directionality of the entity.ro JnxoptIfDirectionality .1.3.6.1.4.1.2636.3.73.1.1.4.1.1.1 |
jnxoptIfOMSnCurrentStatusIndicates the defect condition of the entity, if any.
This object is applicable only to full capability
systems whose interface type is IaDI and for which
jnxoptIfOMSnDirectionality has the value sink(1) or
bidirectional(3).ro Bits .1.3.6.1.4.1.2636.3.73.1.1.4.1.1.2 |
jnxoptIfOMSnSinkCurrentTableA table of OMSn sink performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOMSnSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.4.2 |
jnxoptIfOMSnSinkCurrentEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface for the current
15-minute interval. JnxoptIfOMSnSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.4.2.1 |
jnxoptIfOMSnSinkCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.1 |
jnxoptIfOMSnSinkCurrentAggregatedInputPowerThe aggregated optical power of all the DWDM input
channels.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.2 |
jnxoptIfOMSnSinkCurrentLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.3 |
jnxoptIfOMSnSinkCurrentHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.4 |
jnxoptIfOMSnSinkCurrentLowerInputPowerThresholdThe lower limit threshold on aggregated input power. If
jnxoptIfOMSnSinkCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.5 |
jnxoptIfOMSnSinkCurrentUpperInputPowerThresholdThe upper limit threshold on aggregated input power. If
jnxoptIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.6 |
jnxoptIfOMSnSinkCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.7 |
jnxoptIfOMSnSinkCurrentLowOutputPowerThe lowest optical power monitored at the output
during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.8 |
jnxoptIfOMSnSinkCurrentHighOutputPowerThe highest optical power monitored at the output
during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.9 |
jnxoptIfOMSnSinkCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
jnxoptIfOMSnSinkCurrentOutputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.10 |
jnxoptIfOMSnSinkCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
jnxoptIfOMSnSinkCurrentOutputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.2.1.11 |
jnxoptIfOMSnSinkIntervalTableA table of historical OMSn sink performance monitoring
information. SEQUENCE OF JnxoptIfOMSnSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.4.3 |
jnxoptIfOMSnSinkIntervalEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOMSnSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.4.3.1 |
jnxoptIfOMSnSinkIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.1 |
jnxoptIfOMSnSinkIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.2 |
jnxoptIfOMSnSinkIntervalLastAggregatedInputPowerThe last aggregated optical power of all the DWDM input
channels during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.3 |
jnxoptIfOMSnSinkIntervalLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.4 |
jnxoptIfOMSnSinkIntervalHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.5 |
jnxoptIfOMSnSinkIntervalLastOutputPowerThe last optical power at the output
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.6 |
jnxoptIfOMSnSinkIntervalLowOutputPowerThe lowest optical power at the output
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.7 |
jnxoptIfOMSnSinkIntervalHighOutputPowerThe highest optical power at the output
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.3.1.8 |
jnxoptIfOMSnSinkCurDayTableA table of OMSn sink performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOMSnSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.4 |
jnxoptIfOMSnSinkCurDayEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOMSnSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.4.1 |
jnxoptIfOMSnSinkCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.4.1.1 |
jnxoptIfOMSnSinkCurDayLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.4.1.2 |
jnxoptIfOMSnSinkCurDayHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.4.1.3 |
jnxoptIfOMSnSinkCurDayLowOutputPowerThe lowest optical power at the output
during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.4.1.4 |
jnxoptIfOMSnSinkCurDayHighOutputPowerThe highest optical power at the output
during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.4.1.5 |
jnxoptIfOMSnSinkPrevDayTableA table of OMSn sink performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOMSnSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.5 |
jnxoptIfOMSnSinkPrevDayEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOMSnSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.5.1 |
jnxoptIfOMSnSinkPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.5.1.1 |
jnxoptIfOMSnSinkPrevDayLastAggregatedInputPowerThe last aggregated optical power of all the DWDM input
channels during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.5.1.2 |
jnxoptIfOMSnSinkPrevDayLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.5.1.3 |
jnxoptIfOMSnSinkPrevDayHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.5.1.4 |
jnxoptIfOMSnSinkPrevDayLastOutputPowerThe last optical power at the output
during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.5.1.5 |
jnxoptIfOMSnSinkPrevDayLowOutputPowerThe lowest optical power at the output
during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.5.1.6 |
jnxoptIfOMSnSinkPrevDayHighOutputPowerThe highest optical power at the output
during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.5.1.7 |
jnxoptIfOMSnSrcCurrentTableA table of OMSn source performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOMSnSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.4.6 |
jnxoptIfOMSnSrcCurrentEntryA conceptual row that contains OMSn source performance
monitoring information of an interface for the current
15-minute interval. JnxoptIfOMSnSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.4.6.1 |
jnxoptIfOMSnSrcCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.1 |
jnxoptIfOMSnSrcCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.2 |
jnxoptIfOMSnSrcCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.3 |
jnxoptIfOMSnSrcCurrentHighOutputPowerThe highest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.4 |
jnxoptIfOMSnSrcCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
jnxoptIfOMSnSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.5 |
jnxoptIfOMSnSrcCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
jnxoptIfOMSnSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.6 |
jnxoptIfOMSnSrcCurrentAggregatedInputPowerThe aggregated optical power at the input.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.7 |
jnxoptIfOMSnSrcCurrentLowAggregatedInputPowerThe lowest aggregated optical power at the input
during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.8 |
jnxoptIfOMSnSrcCurrentHighAggregatedInputPowerThe highest aggregated optical power at the input
during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.9 |
jnxoptIfOMSnSrcCurrentLowerInputPowerThresholdThe lower limit threshold on aggregated input power. If
jnxoptIfOMSnSrcCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.10 |
jnxoptIfOMSnSrcCurrentUpperInputPowerThresholdThe upper limit threshold on aggregated input power. If
jnxoptIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.6.1.11 |
jnxoptIfOMSnSrcIntervalTableA table of historical OMSn source performance monitoring
information. SEQUENCE OF JnxoptIfOMSnSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.4.7 |
jnxoptIfOMSnSrcIntervalEntryA conceptual row that contains OMSn source performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOMSnSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.4.7.1 |
jnxoptIfOMSnSrcIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.1 |
jnxoptIfOMSnSrcIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.2 |
jnxoptIfOMSnSrcIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.3 |
jnxoptIfOMSnSrcIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.4 |
jnxoptIfOMSnSrcIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.5 |
jnxoptIfOMSnSrcIntervalLastAggregatedInputPowerThe last aggregated optical power at the input
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.6 |
jnxoptIfOMSnSrcIntervalLowAggregatedInputPowerThe lowest aggregated optical power at the input
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.7 |
jnxoptIfOMSnSrcIntervalHighAggregatedInputPowerThe highest aggregated optical power at the input
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.7.1.8 |
jnxoptIfOMSnSrcCurDayTableA table of OMSn source performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOMSnSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.8 |
jnxoptIfOMSnSrcCurDayEntryA conceptual row that contains OMSn source performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOMSnSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.8.1 |
jnxoptIfOMSnSrcCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.8.1.1 |
jnxoptIfOMSnSrcCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.8.1.2 |
jnxoptIfOMSnSrcCurDayHighOutputPowerThe highest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.8.1.3 |
jnxoptIfOMSnSrcCurDayLowAggregatedInputPowerThe lowest aggregated optical power at the input
during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.8.1.4 |
jnxoptIfOMSnSrcCurDayHighAggregatedInputPowerThe highest aggregated optical power at the input
during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.8.1.5 |
jnxoptIfOMSnSrcPrevDayTableA table of OMSn source performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOMSnSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.9 |
jnxoptIfOMSnSrcPrevDayEntryA conceptual row that contains OMSn source performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOMSnSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.4.9.1 |
jnxoptIfOMSnSrcPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.4.9.1.1 |
jnxoptIfOMSnSrcPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.9.1.2 |
jnxoptIfOMSnSrcPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.9.1.3 |
jnxoptIfOMSnSrcPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.9.1.4 |
jnxoptIfOMSnSrcPrevDayLastAggregatedInputPowerThe last aggregated optical power at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.9.1.5 |
jnxoptIfOMSnSrcPrevDayLowAggregatedInputPowerThe lowest aggregated optical power at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.9.1.6 |
jnxoptIfOMSnSrcPrevDayHighAggregatedInputPowerThe highest aggregated optical power at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.4.9.1.7 |
jnxoptIfOChGroup OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.5 |
jnxoptIfOChGroupConfigTableA table of OChGroup configuration information. SEQUENCE OF JnxoptIfOChGroupConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.5.1 |
jnxoptIfOChGroupConfigEntryA conceptual row that contains OChGroup configuration
information of an interface. JnxoptIfOChGroupConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.5.1.1 |
jnxoptIfOChGroupDirectionalityIndicates the directionality of the entity.ro JnxoptIfDirectionality .1.3.6.1.4.1.2636.3.73.1.1.5.1.1.1 |
jnxoptIfOChGroupSinkCurrentTableA table of OChGroup sink performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOChGroupSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.5.2 |
jnxoptIfOChGroupSinkCurrentEntryA conceptual row that contains OChGroup sink performance
monitoring information of an interface for the current
15-minute interval. JnxoptIfOChGroupSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.5.2.1 |
jnxoptIfOChGroupSinkCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.1 |
jnxoptIfOChGroupSinkCurrentAggregatedInputPowerThe aggregated optical power of all the DWDM input
channels in the OChGroup.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.2 |
jnxoptIfOChGroupSinkCurrentLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.3 |
jnxoptIfOChGroupSinkCurrentHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.4 |
jnxoptIfOChGroupSinkCurrentLowerInputPowerThresholdThe lower limit threshold on aggregated input power. If
jnxoptIfOChGroupSinkCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.5 |
jnxoptIfOChGroupSinkCurrentUpperInputPowerThresholdThe upper limit threshold on aggregated input power. If
jnxoptIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.6 |
jnxoptIfOChGroupSinkCurrentOutputPowerThe optical power monitored at the output
in the OChGroup.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.7 |
jnxoptIfOChGroupSinkCurrentLowOutputPowerThe lowest optical power monitored at the output
in the OChGroup during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.8 |
jnxoptIfOChGroupSinkCurrentHighOutputPowerThe highest optical power monitored at the output
in the OChGroup during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.9 |
jnxoptIfOChGroupSinkCurrentLowerOutputPowerThresholdThe lower limit threshold on the output power. If
jnxoptIfOChGroupSinkCurrentOutputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.10 |
jnxoptIfOChGroupSinkCurrentUpperOutputPowerThresholdThe upper limit threshold on the output power. If
jnxoptIfOChGroupSinkCurrentOutputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.2.1.11 |
jnxoptIfOChGroupSinkIntervalTableA table of historical OChGroup sink performance monitoring
information. SEQUENCE OF JnxoptIfOChGroupSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.5.3 |
jnxoptIfOChGroupSinkIntervalEntryA conceptual row that contains OChGroup sink performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOChGroupSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.5.3.1 |
jnxoptIfOChGroupSinkIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.1 |
jnxoptIfOChGroupSinkIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.2 |
jnxoptIfOChGroupSinkIntervalLastAggregatedInputPowerThe last aggregated optical power of all the DWDM input
channels in the OChGroup during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.3 |
jnxoptIfOChGroupSinkIntervalLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.4 |
jnxoptIfOChGroupSinkIntervalHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels in the OChGroup during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.5 |
jnxoptIfOChGroupSinkIntervalLastOutputPowerThe last optical power monitored at the output
in the OChGroup during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.6 |
jnxoptIfOChGroupSinkIntervalLowOutputPowerThe lowest optical power monitored at the output
in the OChGroup during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.7 |
jnxoptIfOChGroupSinkIntervalHighOutputPowerThe highest optical power monitored at the output
in the OChGroup during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.3.1.8 |
jnxoptIfOChGroupSinkCurDayTableA table of OChGroup sink performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOChGroupSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.4 |
jnxoptIfOChGroupSinkCurDayEntryA conceptual row that contains OChGroup sink performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOChGroupSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.4.1 |
jnxoptIfOChGroupSinkCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.4.1.1 |
jnxoptIfOChGroupSinkCurDayLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.4.1.2 |
jnxoptIfOChGroupSinkCurDayHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.4.1.3 |
jnxoptIfOChGroupSinkCurDayLowOutputPowerThe lowest optical power monitored at the output
in the OChGroup during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.4.1.4 |
jnxoptIfOChGroupSinkCurDayHighOutputPowerThe highest optical power monitored at the output
in the OChGroup during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.4.1.5 |
jnxoptIfOChGroupSinkPrevDayTableA table of OChGroup sink performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOChGroupSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.5 |
jnxoptIfOChGroupSinkPrevDayEntryA conceptual row that contains OChGroup sink performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOChGroupSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.5.1 |
jnxoptIfOChGroupSinkPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.5.1.1 |
jnxoptIfOChGroupSinkPrevDayLastAggregatedInputPowerThe last aggregated optical power of all the DWDM input
channels in the OChGroup during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.5.1.2 |
jnxoptIfOChGroupSinkPrevDayLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.5.1.3 |
jnxoptIfOChGroupSinkPrevDayHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels in the OChGroup during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.5.1.4 |
jnxoptIfOChGroupSinkPrevDayLastOutputPowerThe last optical power monitored at the output
in the OChGroup during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.5.1.5 |
jnxoptIfOChGroupSinkPrevDayLowOutputPowerThe lowest optical power monitored at the output
in the OChGroup during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.5.1.6 |
jnxoptIfOChGroupSinkPrevDayHighOutputPowerThe highest optical power monitored at the output
in the OChGroup during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.5.1.7 |
jnxoptIfOChGroupSrcCurrentTableA table of OChGroup source performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOChGroupSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.5.6 |
jnxoptIfOChGroupSrcCurrentEntryA conceptual row that contains OChGroup source performance
monitoring information of an interface for the current
15-minute interval. JnxoptIfOChGroupSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.5.6.1 |
jnxoptIfOChGroupSrcCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.1 |
jnxoptIfOChGroupSrcCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.2 |
jnxoptIfOChGroupSrcCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.3 |
jnxoptIfOChGroupSrcCurrentHighOutputPowerThe highest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.4 |
jnxoptIfOChGroupSrcCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
jnxoptIfOChGroupSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.5 |
jnxoptIfOChGroupSrcCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
jnxoptIfOChGroupSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.6 |
jnxoptIfOChGroupSrcCurrentAggregatedInputPowerThe aggregated optical power monitored at the input.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.7 |
jnxoptIfOChGroupSrcCurrentLowAggregatedInputPowerThe lowest aggregated optical power monitored at the input
during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.8 |
jnxoptIfOChGroupSrcCurrentHighAggregatedInputPowerThe highest aggregated optical power monitored at the input
during the current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.9 |
jnxoptIfOChGroupSrcCurrentLowerInputPowerThresholdThe lower limit threshold on input power. If
jnxoptIfOChGroupSrcCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.10 |
jnxoptIfOChGroupSrcCurrentUpperInputPowerThresholdThe upper limit threshold on input power. If
jnxoptIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.6.1.11 |
jnxoptIfOChGroupSrcIntervalTableA table of historical OChGroup source performance monitoring
information. SEQUENCE OF JnxoptIfOChGroupSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.5.7 |
jnxoptIfOChGroupSrcIntervalEntryA conceptual row that contains OChGroup source performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOChGroupSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.5.7.1 |
jnxoptIfOChGroupSrcIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.1 |
jnxoptIfOChGroupSrcIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.2 |
jnxoptIfOChGroupSrcIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.3 |
jnxoptIfOChGroupSrcIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.4 |
jnxoptIfOChGroupSrcIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.5 |
jnxoptIfOChGroupSrcIntervalLastAggregatedInputPowerThe last aggregated optical power monitored at the input
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.6 |
jnxoptIfOChGroupSrcIntervalLowAggregatedInputPowerThe lowest aggregated optical power monitored at the input
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.7 |
jnxoptIfOChGroupSrcIntervalHighAggregatedInputPowerThe highest aggregated optical power monitored at the input
during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.7.1.8 |
jnxoptIfOChGroupSrcCurDayTableA table of OChGroup source performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOChGroupSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.8 |
jnxoptIfOChGroupSrcCurDayEntryA conceptual row that contains OChGroup source performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOChGroupSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.8.1 |
jnxoptIfOChGroupSrcCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.8.1.1 |
jnxoptIfOChGroupSrcCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.8.1.2 |
jnxoptIfOChGroupSrcCurDayHighOutputPowerThe highest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.8.1.3 |
jnxoptIfOChGroupSrcCurDayLowAggregatedInputPowerThe lowest aggregated optical power monitored at the input
during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.8.1.4 |
jnxoptIfOChGroupSrcCurDayHighAggregatedInputPowerThe highest aggregated optical power monitored at the input
during the current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.8.1.5 |
jnxoptIfOChGroupSrcPrevDayTableA table of OChGroup source performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOChGroupSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.9 |
jnxoptIfOChGroupSrcPrevDayEntryA conceptual row that contains OChGroup source performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOChGroupSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.5.9.1 |
jnxoptIfOChGroupSrcPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.5.9.1.1 |
jnxoptIfOChGroupSrcPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.9.1.2 |
jnxoptIfOChGroupSrcPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.9.1.3 |
jnxoptIfOChGroupSrcPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.9.1.4 |
jnxoptIfOChGroupSrcPrevDayLastAggregatedInputPowerThe last aggregated optical power monitored at the input
during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.9.1.5 |
jnxoptIfOChGroupSrcPrevDayLowAggregatedInputPowerThe lowest aggregated optical power monitored at the input
during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.9.1.6 |
jnxoptIfOChGroupSrcPrevDayHighAggregatedInputPowerThe highest aggregated optical power monitored at the input
during the previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.5.9.1.7 |
jnxoptIfOCh OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.6 |
jnxoptIfOChConfigTableA table of OCh configuration information. SEQUENCE OF JnxoptIfOChConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.6.1 |
jnxoptIfOChConfigEntryA conceptual row that contains OCh configuration
information of an interface. JnxoptIfOChConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.6.1.1 |
jnxoptIfOChDirectionalityIndicates the directionality of the entity.ro JnxoptIfDirectionality .1.3.6.1.4.1.2636.3.73.1.1.6.1.1.1 |
jnxoptIfOChCurrentStatusIndicates the defect condition of the entity, if any.
This object is applicable when jnxoptIfOChDirectionality
has the value sink(1) or bidirectional(3).
In full-capability systems the bit position los(1) is not used.
In reduced-capability systems or at IrDI interfaces only
the bit positions los(1) and ssfP(3) are used.ro Bits .1.3.6.1.4.1.2636.3.73.1.1.6.1.1.2 |
jnxoptIfOChSinkCurrentTableA table of OCh sink performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOChSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.6.2 |
jnxoptIfOChSinkCurrentEntryA conceptual row that contains OCh sink performance
monitoring information for an interface for the current
15-minute interval. JnxoptIfOChSinkCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.6.2.1 |
jnxoptIfOChSinkCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.2.1.1 |
jnxoptIfOChSinkCurrentInputPowerThe optical power monitored at the input.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.2.1.2 |
jnxoptIfOChSinkCurrentLowInputPowerThe lowest optical power monitored at the input during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.2.1.3 |
jnxoptIfOChSinkCurrentHighInputPowerThe highest optical power monitored at the input during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.2.1.4 |
jnxoptIfOChSinkCurrentLowerInputPowerThresholdThe lower limit threshold on input power. If
jnxoptIfOChSinkCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.2.1.5 |
jnxoptIfOChSinkCurrentUpperInputPowerThresholdThe upper limit threshold on input power. If
jnxoptIfOChSinkCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.2.1.6 |
jnxoptIfOChSinkIntervalTableA table of historical OCh sink performance monitoring
information. SEQUENCE OF JnxoptIfOChSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.6.3 |
jnxoptIfOChSinkIntervalEntryA conceptual row that contains OCh sink performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOChSinkIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.6.3.1 |
jnxoptIfOChSinkIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.6.3.1.1 |
jnxoptIfOChSinkIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.3.1.2 |
jnxoptIfOChSinkIntervalLastInputPowerThe last optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.3.1.3 |
jnxoptIfOChSinkIntervalLowInputPowerThe lowest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.3.1.4 |
jnxoptIfOChSinkIntervalHighInputPowerThe highest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.3.1.5 |
jnxoptIfOChSinkCurDayTableA table of OCh sink performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOChSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.4 |
jnxoptIfOChSinkCurDayEntryA conceptual row that contains OCh sink performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOChSinkCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.4.1 |
jnxoptIfOChSinkCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.4.1.1 |
jnxoptIfOChSinkCurDayLowInputPowerThe lowest optical power monitored at the input during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.4.1.2 |
jnxoptIfOChSinkCurDayHighInputPowerThe highest optical power monitored at the input during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.4.1.3 |
jnxoptIfOChSinkPrevDayTableA table of OCh sink performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOChSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.5 |
jnxoptIfOChSinkPrevDayEntryA conceptual row that contains OCh sink performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOChSinkPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.5.1 |
jnxoptIfOChSinkPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.5.1.1 |
jnxoptIfOChSinkPrevDayLastInputPowerThe last optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.5.1.2 |
jnxoptIfOChSinkPrevDayLowInputPowerThe lowest optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.5.1.3 |
jnxoptIfOChSinkPrevDayHighInputPowerThe highest optical power monitored at the input during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.5.1.4 |
jnxoptIfOChSrcCurrentTableA table of OCh source performance monitoring information for
the current 15-minute interval. SEQUENCE OF JnxoptIfOChSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.6.6 |
jnxoptIfOChSrcCurrentEntryA conceptual row that contains OCh source performance
monitoring information of an interface for the current
15-minute interval. JnxoptIfOChSrcCurrentEntry .1.3.6.1.4.1.2636.3.73.1.1.6.6.1 |
jnxoptIfOChSrcCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.6.1.1 |
jnxoptIfOChSrcCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.6.1.2 |
jnxoptIfOChSrcCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.6.1.3 |
jnxoptIfOChSrcCurrentHighOutputPowerThe highest optical power monitored at the output during the
current 15-minute interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.6.1.4 |
jnxoptIfOChSrcCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
jnxoptIfOChSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.6.1.5 |
jnxoptIfOChSrcCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
jnxoptIfOChSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.6.1.6 |
jnxoptIfOChSrcIntervalTableA table of historical OCh source performance monitoring
information. SEQUENCE OF JnxoptIfOChSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.6.7 |
jnxoptIfOChSrcIntervalEntryA conceptual row that contains OCh source performance
monitoring information of an interface during a particular
historical interval. JnxoptIfOChSrcIntervalEntry .1.3.6.1.4.1.2636.3.73.1.1.6.7.1 |
jnxoptIfOChSrcIntervalNumberUniquely identifies the interval. JnxoptIfIntervalNumber .1.3.6.1.4.1.2636.3.73.1.1.6.7.1.1 |
jnxoptIfOChSrcIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.7.1.2 |
jnxoptIfOChSrcIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.7.1.3 |
jnxoptIfOChSrcIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.7.1.4 |
jnxoptIfOChSrcIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.7.1.5 |
jnxoptIfOChSrcCurDayTableA table of OCh source performance monitoring information for
the current 24-hour interval. SEQUENCE OF JnxoptIfOChSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.8 |
jnxoptIfOChSrcCurDayEntryA conceptual row that contains OCh source performance
monitoring information of an interface for the current
24-hour interval. JnxoptIfOChSrcCurDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.8.1 |
jnxoptIfOChSrcCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.8.1.1 |
jnxoptIfOChSrcCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.8.1.2 |
jnxoptIfOChSrcCurDayHighOutputPowerThe highest optical power monitored at the output during the
current 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.8.1.3 |
jnxoptIfOChSrcPrevDayTableA table of OCh source performance monitoring information for
the previous 24-hour interval. SEQUENCE OF JnxoptIfOChSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.9 |
jnxoptIfOChSrcPrevDayEntryA conceptual row that contains OCh source performance
monitoring information of an interface for the previous
24-hour interval. JnxoptIfOChSrcPrevDayEntry .1.3.6.1.4.1.2636.3.73.1.1.6.9.1 |
jnxoptIfOChSrcPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.6.9.1.1 |
jnxoptIfOChSrcPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.9.1.2 |
jnxoptIfOChSrcPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.9.1.3 |
jnxoptIfOChSrcPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous 24-hour interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.2636.3.73.1.1.6.9.1.4 |
jnxoptIfOTUk OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.7 |
jnxoptIfOTUkConfigTableA table of OTUk configuration information. SEQUENCE OF JnxoptIfOTUkConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.7.1 |
jnxoptIfOTUkConfigEntryA conceptual row that contains OTUk configuration
information of an interface. JnxoptIfOTUkConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.7.1.1 |
jnxoptIfOTUkDirectionalityIndicates the directionality of the entity.ro JnxoptIfDirectionality .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.1 |
jnxoptIfOTUkBitRateKIndicates the bit rate of the entity.ro JnxoptIfBitRateK .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.2 |
jnxoptIfOTUkTraceIdentifierTransmittedThe trace identifier transmitted.
This object is applicable when jnxoptIfOTUkDirectionality
has the value source(2) or bidirectional(3). It must not
be instantiated in rows where jnxoptIfOTUkDirectionality
has the value sink(1).
If no value is ever set by a management entity for this
object, system-specific default value will be used.
Any implementation that instantiates this object must
document the system-specific default value or how it
is derived.rw JnxoptIfTxTI .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.3 |
jnxoptIfOTUkDAPIExpectedThe DAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
This object has no effect when jnxoptIfOTUkTIMDetMode has
the value off(1).rw JnxoptIfExDAPI .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.4 |
jnxoptIfOTUkSAPIExpectedThe SAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
This object has no effect when jnxoptIfOTUkTIMDetMode has
the value off(1).rw JnxoptIfExSAPI .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.5 |
jnxoptIfOTUkTraceIdentifierAcceptedThe actual trace identifier accepted.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
The value of this object is unspecified when
jnxoptIfOTUkCurrentStatus indicates a near-end defect
(i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents
extraction of the trace message.ro JnxoptIfAcTI .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.6 |
jnxoptIfOTUkTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
The default value of this object is off(1).rw JnxoptIfTIMDetMode .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.7 |
jnxoptIfOTUkTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
This object has no effect when jnxoptIfOTUkTIMDetMode has
the value off(1).
The default value of this object is false(2).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.8 |
jnxoptIfOTUkDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to jnxoptIfOTUkDEGThr.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
The default value of this object is Severely Errored Second
(SES) Estimator (See ITU-T G.7710).rw JnxoptIfDEGThr UNITS "percentage" .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.9 |
jnxoptIfOTUkDEGMIndicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if jnxoptIfOTUkDEGM
consecutive bad PM Seconds are detected.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
The default value of this object is 7 (See ITU-T G.7710).rw JnxoptIfDEGM .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.10 |
jnxoptIfOTUkSinkAdaptActiveIndicates whether the sink adaptation function is activated or
not.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
The default value of this object is false(2).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.11 |
jnxoptIfOTUkSourceAdaptActiveIndicates whether the source adaptation function is activated or
not.
This object is only applicable to the source function, i.e.,
only when jnxoptIfOTUkDirectionality has the value source(2)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value sink(1).
The default value of this object is false(2).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.12 |
jnxoptIfOTUkSinkFECEnabledIf Forward Error Correction (FEC) is supported, this object
indicates whether FEC at the OTUk sink adaptation function is
enabled or not.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).
The default value of this object is true(1).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.13 |
jnxoptIfOTUkCurrentStatusIndicates the defect condition of the entity, if any.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfOTUkDirectionality has the value source(2).ro Bits .1.3.6.1.4.1.2636.3.73.1.1.7.1.1.14 |
jnxoptIfGCC0ConfigTableA table of GCC0 configuration information. SEQUENCE OF JnxoptIfGCC0ConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.7.2 |
jnxoptIfGCC0ConfigEntryA conceptual row that contains GCC0 configuration
information of an interface. Each instance must
correspond to an instance of jnxoptIfOTUkConfigEntry.
Separate source and/or sink instances may exist
for a given ifIndex value, or a single bidirectional
instance may exist, but a bidirectional instance may
not coexist with a source or sink instance.
Instances of this conceptual row persist across
agent restarts. JnxoptIfGCC0ConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.7.2.1 |
jnxoptIfGCC0DirectionalityIndicates the directionality of the entity.
The values source(2) and bidirectional(3) are
not allowed if the corresponding instance of
jnxoptIfOTUkDirectionality has the value sink(1).
The values sink(1) and bidirectional(3) are
not allowed if the corresponding instance of
jnxoptIfOTUkDirectionality has the value source(2). JnxoptIfDirectionality .1.3.6.1.4.1.2636.3.73.1.1.7.2.1.1 |
jnxoptIfGCC0ApplicationIndicates the application transported by the GCC0 entity.
Example applications are ECC, User data channel.
The value of this object may not be changed when
jnxoptIfGCC0RowStatus has the value active(1).rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2636.3.73.1.1.7.2.1.2 |
jnxoptIfGCC0RowStatusThis columnar object is used for creating and deleting a
conceptual row of the jnxoptIfGCC0 config table.
It is used to model the addGCC0Access and removeGCC0Access
operations of an OTUk_TTP for GCC0 access control as defined
in G.874.1. Setting RowStatus to createAndGo or createAndWait
implies addGCC0Access. Setting RowStatus to destroy implies
removeGCC0Access.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.7.2.1.3 |
jnxoptIfODUk OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.8 |
jnxoptIfODUkConfigTableA table of ODUk configuration information. SEQUENCE OF JnxoptIfODUkConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.1 |
jnxoptIfODUkConfigEntryA conceptual row that contains ODUk configuration
information of an interface. JnxoptIfODUkConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.1.1 |
jnxoptIfODUkDirectionalityIndicates the directionality of the entity.ro JnxoptIfDirectionality .1.3.6.1.4.1.2636.3.73.1.1.8.1.1.1 |
jnxoptIfODUkBitRateKIndicates the bit rate of the entity.ro JnxoptIfBitRateK .1.3.6.1.4.1.2636.3.73.1.1.8.1.1.2 |
jnxoptIfODUkTcmFieldsInUseIndicates the TCM field(s) that are currently in use.
The positions of the bits correspond to the TCM fields.
A bit that is set to 1 means that the corresponding TCM
field is used. This object will be updated when rows are
created in or deleted from the jnxoptIfODUkTConfigTable, or
the jnxoptIfODUkTNimConfigTable.ro Bits .1.3.6.1.4.1.2636.3.73.1.1.8.1.1.3 |
jnxoptIfODUkPositionSeqCurrentSizeThis variable indicates the current size of the position
sequence (i.e., number of TCM function and/or GCC12
access that have been created in the ODUk interface).
When the value of this variable is greater than zero,
it means that one or more TCM function and/or GCC12
access have been created in the ODUk interface. In this
case, there will be as many rows in the
jnxoptIfODUkPositionSeqTable as the value of
jnxoptIfODUkPositionSeqCurrentSize corresponding to this
ODUk interface, one row for each TCM function or GCC12
access. The position of the TCM function and/or
GCC12 access within the sequence is indicated by the
jnxoptIfODUkPositionSeqPosition variable in
jnxoptIfODUkPositionSeqTable.
The jnxoptIfODUkPositionSeqTable also provides pointers
to the corresponding TCM function (jnxoptIfODUkT) and
GCC12 access (jnxoptIfGCC12) entities.ro Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.8.1.1.4 |
jnxoptIfODUkTtpPresentThis object has the value true(1) if the ifEntry under which
it is instantiated contains an ODUk Trail Termination Point,
i.e., is the endpoint of an ODUk path. In that case there
will be a corresponding row in the ODUk TTP config table and
it will not be possible to create corresponding rows in the
ODUk NIM config table. This object has the value false(2)
if the ifEntry under which it is instantiated contains an
intermediate ODUk Connection Termination Point. In that case
there is no corresponding row in the ODUk TTP config table,
but it will be possible to create corresponding rows in the
ODUk NIM config table. This object also affects the allowable
options in rows created in the GCC12 config table and in the
ODUkT config table, as specified in the DESCRIPTION clauses
of the columns in those tables.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.1.1.5 |
jnxoptIfODUkTtpConfigTableA table of ODUk TTP configuration information. SEQUENCE OF JnxoptIfODUkTtpConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.2 |
jnxoptIfODUkTtpConfigEntryA conceptual row that contains ODUk TTP configuration
information of an interface. JnxoptIfODUkTtpConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.2.1 |
jnxoptIfODUkTtpTraceIdentifierTransmittedThe trace identifier transmitted.
This object is applicable when jnxoptIfODUkDirectionality
has the value source(2) or bidirectional(3). It must not
be instantiated in rows where jnxoptIfODUkDirectionality
has the value sink(1).
If no value is ever set by a management entity for this
object, system-specific default value will be used.
Any implementation that instantiates this object must
document the system-specific default value or how it
is derived.rw JnxoptIfTxTI .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.1 |
jnxoptIfODUkTtpDAPIExpectedThe DAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).
This object has no effect when jnxoptIfODUkTtpTIMDetMode has
the value off(1).rw JnxoptIfExDAPI .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.2 |
jnxoptIfODUkTtpSAPIExpectedThe SAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).
This object has no effect when jnxoptIfODUkTtpTIMDetMode has
the value off(1).rw JnxoptIfExSAPI .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.3 |
jnxoptIfODUkTtpTraceIdentifierAcceptedThe actual trace identifier accepted.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).
The value of this object is unspecified when
jnxoptIfODUkTtpCurrentStatus indicates a near-end defect
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
of the trace message.ro JnxoptIfAcTI .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.4 |
jnxoptIfODUkTtpTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).
The default value of this object is off(1).rw JnxoptIfTIMDetMode .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.5 |
jnxoptIfODUkTtpTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).
This object has no effect when jnxoptIfODUkTtpTIMDetMode has
the value off(1).
The default value of this object is false(2).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.6 |
jnxoptIfODUkTtpDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to jnxoptIfODUkDEGThr.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).
The default value of this object is Severely Errored Second
(SES) Estimator (See ITU-T G.7710).rw JnxoptIfDEGThr UNITS "percentage" .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.7 |
jnxoptIfODUkTtpDEGMIndicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if jnxoptIfODUkDEGM
consecutive bad PM Seconds are detected.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).
The default value of this object is 7 (See ITU-T G.7710).rw JnxoptIfDEGM .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.8 |
jnxoptIfODUkTtpCurrentStatusIndicates the defect condition of the entity, if any.
This object is only applicable to the sink function, i.e.,
only when jnxoptIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where jnxoptIfODUkDirectionality has the value source(2).ro Bits .1.3.6.1.4.1.2636.3.73.1.1.8.2.1.9 |
jnxoptIfODUkPositionSeqTableA table of ODUk Position Sequence information. SEQUENCE OF JnxoptIfODUkPositionSeqEntry .1.3.6.1.4.1.2636.3.73.1.1.8.3 |
jnxoptIfODUkPositionSeqEntryA conceptual row that contains ODUk position sequence
information of an ODUk interface. The ODUk interface
is identified by the ifIndex. Associated with each
ODUk interface there may be one of more conceptual
rows in the jnxoptIfODUkPositionSeqTable. Each row
represents a TCM or GCC12 access function within the
associated ODUk interface. Rows of the
jnxoptIfODUkPositionSeqTable table are created/deleted
as the result of the creation/deletion of the jnxoptIfODUkT
or jnxoptIfGCC12 entities. JnxoptIfODUkPositionSeqEntry .1.3.6.1.4.1.2636.3.73.1.1.8.3.1 |
jnxoptIfODUkPositionSeqIndexThis variable identifies a row in the
jnxoptIfODUkPositionSeqTable Table.
Each row of the jnxoptIfODUkPositionSeqTable Table
represents a TCM or GCC12 access function within the
associated ODUk interface. Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.8.3.1.1 |
jnxoptIfODUkPositionSeqPositionThis variable indicates the position of the TCM or
GCC12 access function within the sequence of TCMs &
GCC12 access functions of the associated ODUk
interface. The TCM or GCC12 presented by this row is
referenced by the jnxoptIfODUkPositionSeqPointer variable.ro Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.8.3.1.2 |
jnxoptIfODUkPositionSeqPointerThis variable identifies the TCM or GCC12 access function
by pointing to the corresponding jnxoptIfODUkT or jnxoptIfGCC12
entity.ro RowPointer (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.3.1.3 |
jnxoptIfODUkNimConfigTableA table of ODUkNim configuration information. SEQUENCE OF JnxoptIfODUkNimConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.4 |
jnxoptIfODUkNimConfigEntryA conceptual row that contains ODUkNim configuration
information of an interface. Each instance must
correspond to an instance of jnxoptIfODUkConfigEntry
for which jnxoptIfODUkTtpPresent has the value false(2).
Instances of this conceptual row persist across
agent restarts, and read-create columns other
than the status column may be modified while the
row is active. JnxoptIfODUkNimConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.4.1 |
jnxoptIfODUkNimDirectionalitySpecifies the monitor point for the ODUk Path non-intrusive
monitoring function. The value source(2) is not allowed
if the corresponding instance of jnxoptIfODUkDirectionality
has the value sink(1), and the value sink(1) is not allowed
if the corresponding instance of jnxoptIfODUkDirectionality
has the value source(2). Either the value sink(1) or
source(2) is allowed if the corresponding instance of
jnxoptIfODUkDirectionality has the value bidirectional(3).
The value sink(1) means monitoring at the sink direction
path signal of the ODUk CTP.
The value source(2) means monitoring at the source direction
path signal of the ODUk CTP. Monitoring the source direction
of an ODUk CTP is necessary in those cases where the ODUk CTP
is at an SNCP (Subnetwork Connection Protection) end (e.g., see
Figure I.1.2/G.874.1). If one would like to get the performance
of the protected connection, one cannot use the NIM function
at both ODUk CTP sinks (before the matrix), instead one should
monitor the signal at the source ODUk CTP after the matrix. JnxoptIfSinkOrSource .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.1 |
jnxoptIfODUkNimDAPIExpectedThe DAPI expected by the receiver.
This object has no effect if jnxoptIfODUkNimTIMDetMode has
the value off(1) or sapi(3).rw JnxoptIfExDAPI .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.2 |
jnxoptIfODUkNimSAPIExpectedThe SAPI expected by the receiver.
This object has no effect if jnxoptIfODUkNimTIMDetMode has
the value off(1) or dapi(2).rw JnxoptIfExSAPI .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.3 |
jnxoptIfODUkNimTraceIdentifierAcceptedThe actual trace identifier accepted. The value of
this object is unspecified if jnxoptIfODUkNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if jnxoptIfODUkNimRowStatus has any value other
than active(1).ro JnxoptIfAcTI .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.4 |
jnxoptIfODUkNimTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.rw JnxoptIfTIMDetMode .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.5 |
jnxoptIfODUkNimTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.6 |
jnxoptIfODUkNimDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad
if the percentage of detected errored blocks in that second is
greater than or equal to jnxoptIfODUkNimDEGThr.rw JnxoptIfDEGThr UNITS "percentage" .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.7 |
jnxoptIfODUkNimDEGMIndicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if jnxoptIfODUkNimDEGM
consecutive bad PM Seconds are detected.rw JnxoptIfDEGM .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.8 |
jnxoptIfODUkNimCurrentStatusIndicates the defect condition of the entity, if
any. The value of this object is unspecified if
jnxoptIfODUkNimRowStatus has any value other than
active(1).ro Bits .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.9 |
jnxoptIfODUkNimRowStatusThis columnar object is used for creating and deleting
a conceptual row of the jnxoptIfODUkNim config table.
It is used to model the activateNim and deactivateNim
operations of an OTUk_CTP for non-intrusive monitoring
control as defined in G.874.1. Setting RowStatus to
createAndGo or createAndWait implies activateNim.
Setting RowStatus to destroy implies deactivateNim.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.4.1.10 |
jnxoptIfGCC12ConfigTableA table of GCC12 configuration information.
The GCC function processes the GCC overhead bytes passing
through them but leave the remainder of the ODUk overhead
and payload data alone. SEQUENCE OF JnxoptIfGCC12ConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.5 |
jnxoptIfGCC12ConfigEntryA conceptual row that contains GCC12 configuration
information of an interface. Each instance must
correspond to an instance of jnxoptIfODUkConfigEntry.
Separate instances providing GCC1-only access and
GCC2-only access may exist for a given ifIndex value,
or a single instance providing GCC1 + GCC2 may exist,
but a GCC1 + GCC2 instance may not coexist with a
GCC1-only or GCC2-only instance.
Instances of this conceptual row persist across agent
restarts. JnxoptIfGCC12ConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.8.5.1 |
jnxoptIfGCC12CodirectionalIndicates the directionality of the GCC12 termination with
respect to the associated ODUk CTP. The value true(1) means
that the sink part of the GCC12 extracts COMMS data from the
signal at the input to the ODUk CTP sink and the source part
of the GCC12 inserts COMMS data into the signal at the output
of the ODUk CTP source. The value false(2) means that the
sink part of the GCC12 extracts COMMS data from the signal at
the output of the ODUk CTP source and the source part of the
GCC12 inserts COMMS data into the signal at the input of the
ODUk CTP sink. This attribute may assume either value when
the corresponding instance of jnxoptIfODUkTtpPresent has the
value false(2). When the value of the corresponding instance
of jnxoptIfODUkTtpPresent is true(1) then the only value allowed
for this attribute is true(1). TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.5.1.1 |
jnxoptIfGCC12GCCAccessIndicates the GCC access represented by the entity. Enumeration .1.3.6.1.4.1.2636.3.73.1.1.8.5.1.2 |
jnxoptIfGCC12GCCPassThroughControls whether the selected GCC overhead bytes are passed
through or modified. The value true(1) means that the selected
GCC overhead bytes are passed through unmodified from the ODUk
CTP input to the ODUk CTP output. The value false(2) means that
the selected GCC overhead bytes are set to zero at the ODUk CTP
output after the extraction of the COMMS data. This object has
no effect if the corresponding instance of jnxoptIfODUkTtpPresent
has the value true(1).
The value of this object may not be changed when
jnxoptIfGCC12RowStatus has the value active(1).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.5.1.3 |
jnxoptIfGCC12ApplicationIndicates the application transported by the GCC12 entity.
Example applications are ECC, User data channel.
The value of this object may not be changed when
jnxoptIfGCC12RowStatus has the value active(1).rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2636.3.73.1.1.8.5.1.4 |
jnxoptIfGCC12RowStatusThis columnar object is used for creating and deleting
a conceptual row of the jnxoptIfGCC12 config table. It is
used to model the addGCC12Access and removeGCC12Access
operations of an ODUk_CTP or ODUk_TTP for GCC12 access
control as defined in G.874.1. Setting RowStatus to
createAndGo or createAndWait implies addGCC12Access.
Setting RowStatus to destroy implies removeGCC12Access.
Successful addition/removal of the GCC12 access function
will result in updating the
jnxoptIfODUkPositionSeqCurrentSize variable and the
jnxoptIfODUkPositionSeqTable table of the associated
ODUk entry in the jnxoptIfODUkConfigTable.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.8.5.1.5 |
jnxoptIfODUkT OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.1.9 |
jnxoptIfODUkTConfigTableA table of ODUkT configuration information. SEQUENCE OF JnxoptIfODUkTConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.9.1 |
jnxoptIfODUkTConfigEntryA conceptual row that contains ODUkT configuration
information of an interface. Each instance must
correspond to an instance of jnxoptIfODUkConfigEntry.
Rows in this table are mutually exclusive with rows
in the ODUkT NIM config table
row object may not be instantiated for a given pair
of ifIndex and TCM field values if a corresponding
instance of jnxoptIfODUkTNimConfigEntry already exists.
Instances of this conceptual row persist across agent
restarts. Except where noted otherwise, read-create
columns other than the status column may be modified
while the row is active. JnxoptIfODUkTConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.9.1.1 |
jnxoptIfODUkTTcmFieldIndicates the tandem connection monitoring
field of the ODUk OH. Valid values are
integers from 1 to 6. Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.1 |
jnxoptIfODUkTCodirectionalIndicates the directionality of the ODUkT termination point with
respect to the associated ODUk CTP. The value true(1) means
that the sink part of the ODUkT TP extracts TCM data from the
signal at the input to the ODUk CTP sink and the source part
of the ODUkT TP inserts TCM data into the signal at the output
of the ODUk CTP source. The value false(2) means that the
sink part of the ODUkT TP extracts TCM data from the signal at
the output of the ODUk CTP source and the source part of the
ODUkT TP inserts TCM data into the signal at the input of the
ODUk CTP sink. This attribute may assume either value when
the corresponding instance of jnxoptIfODUkTtpPresent has the
value false(2). When the value of the corresponding instance
of jnxoptIfODUkTtpPresent is true(1) then the only value allowed
for this attribute is true(1). TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.2 |
jnxoptIfODUkTTraceIdentifierTransmittedThe trace identifier transmitted.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value false(2), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value true(1).
It must not be instantiated in rows for all other cases.rw JnxoptIfTxTI .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.3 |
jnxoptIfODUkTDAPIExpectedThe DAPI expected by the receiver.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when jnxoptIfODUkTTIMDetMode has
the value off(1).rw JnxoptIfExDAPI .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.4 |
jnxoptIfODUkTSAPIExpectedThe SAPI expected by the receiver.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when jnxoptIfODUkTTIMDetMode has
the value off(1).rw JnxoptIfExSAPI .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.5 |
jnxoptIfODUkTTraceIdentifierAcceptedThe actual trace identifier accepted.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The value of this object is unspecified when
jnxoptIfODUkTCurrentStatus indicates a near-end defect
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
of the trace message.ro JnxoptIfAcTI .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.6 |
jnxoptIfODUkTTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The default value of this object is off(1).rw JnxoptIfTIMDetMode .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.7 |
jnxoptIfODUkTTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when jnxoptIfODUkTTIMDetMode has
the value off(1).
The default value of this object is false(2).rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.8 |
jnxoptIfODUkTDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to jnxoptIfODUkTDEGThr.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The default value of this object is Severely Errored Second
(SES) Estimator (See ITU-T G.7710).rw JnxoptIfDEGThr UNITS "percentage" .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.9 |
jnxoptIfODUkTDEGMIndicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if jnxoptIfODUkTDEGM
consecutive bad PM Seconds are detected.
This object is applicable only to the following three cases.
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The default value of this object is 7 (See ITU-T G.7710).rw JnxoptIfDEGM .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.10 |
jnxoptIfODUkTSinkModeThis variable specifies the TCM mode at the entity.
The value operational(1) means that TCM Overhead (TCMOH)
processes (see ITU-T G.798) shall be
performed and consequent actions for AIS, Trail
Signal Fail (TSF), Trail Signal Degraded (TSD) shall be
initiated in case of defects.
The value monitor(2) means that TCMOH processes shall be
performed but consequent actions for AIS, Trail
Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be
initiated in case of defects.
This object is applicable only when the value of
jnxoptIfODUkTtpPresent is false(2) and also either one of the
following three cases holds:
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.rw Enumeration .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.11 |
jnxoptIfODUkTSinkLockSignalAdminStateProvides the capability to provision the LOCK signal, which
is one of the ODUk maintenance signals, at the ODUKT sink. When
a Tandem Connection endpoint is set to admin state locked,
it inserts the ODUk-LCK signal in the sink direction.
This object is applicable only when the value of
jnxoptIfODUkTtpPresent is false(2) and also either one of the
following three cases holds:
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.rw Enumeration .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.12 |
jnxoptIfODUkTSourceLockSignalAdminStateProvides the capability to provision the LOCK signal, which
is one of the ODUk maintenance signals, at the source.
When a Tandem Connection endpoint is set to admin state
locked, it inserts the ODUk-LCK signal in the source
direction.
This object is applicable only when either one of the
following three cases holds:
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value false(2), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value true(1).
It must not be instantiated in rows for all other cases.rw Enumeration .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.13 |
jnxoptIfODUkTCurrentStatusIndicates the defect condition of the entity, if any.
This object is applicable only when either one of the
following three cases holds:
(i) jnxoptIfODUkDirectionality has the value bidirectional(3), or
(ii) jnxoptIfODUkDirectionality has the value sink(1) and
jnxoptIfODUkTCodirectional has the value true(1), or
(iii) jnxoptIfODUkDirectionality has the value source(3) and
jnxoptIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.ro Bits .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.14 |
jnxoptIfODUkTRowStatusThis columnar object is used for creating and deleting a
conceptual row of the jnxoptIfODUkT config table.
It is used to model the addTCM and removeTCM operations of an
ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined
in ITU-T G.874.1.
Setting RowStatus to createAndGo or createAndWait implies addTCM.
Setting RowStatus to destroy implies removeTCM.
Successful addition/removal of TCM will result in updating the
jnxoptIfODUkTcmFieldsInUse and jnxoptIfODUkPositionSeqCurrentSize
variables and the jnxoptIfODUkPositionSeqTable table of the
associated ODUk entry in the jnxoptIfODUkConfigTable.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.9.1.1.15 |
jnxoptIfODUkTNimConfigTableA table of ODUkTNim configuration information. SEQUENCE OF JnxoptIfODUkTNimConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.9.2 |
jnxoptIfODUkTNimConfigEntryA conceptual row that contains ODUkTNim configuration
information of an interface. Each instance must
correspond to an instance of jnxoptIfODUkConfigEntry.
Rows in this table are mutually exclusive with rows
in the ODUkT config table
row object may not be instantiated for a given pair
of ifIndex and TCM field values if a corresponding
instance of jnxoptIfODUkTConfigEntry already exists.
Instances of this conceptual row persist across
agent restarts, and read-create columns other
than the status column may be modified while the
row is active. JnxoptIfODUkTNimConfigEntry .1.3.6.1.4.1.2636.3.73.1.1.9.2.1 |
jnxoptIfODUkTNimTcmFieldIndicates the tandem connection monitoring
field of the ODUk OH on which non-intrusive monitoring
is performed. Valid values are
integers from 1 to 6. Unsigned32 .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.1 |
jnxoptIfODUkTNimDirectionalitySpecifies the monitor point for the ODUk TCM non-intrusive
monitoring function. The value source(2) is not allowed
if the corresponding instance of jnxoptIfODUkDirectionality
has the value sink(1), and the value sink(1) is not allowed
if the corresponding instance of jnxoptIfODUkDirectionality
has the value source(2). Either the value sink(1) or
source(2) is allowed if the corresponding instance of
jnxoptIfODUkDirectionality has the value bidirectional(3).
The value sink(1) means monitoring at the sink direction
TCM signal of the ODUk CTP.
The value source(2) means monitoring at the source direction
path signal of the ODUk CTP. JnxoptIfSinkOrSource .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.2 |
jnxoptIfODUkTNimDAPIExpectedThe DAPI expected by the receiver.
This object has no effect if jnxoptIfODUkTNimTIMDetMode has
the value off(1) or sapi(3).rw JnxoptIfExDAPI .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.3 |
jnxoptIfODUkTNimSAPIExpectedThe SAPI expected by the receiver.
This object has no effect if jnxoptIfODUkTNimTIMDetMode has
the value off(1) or dapi(2).rw JnxoptIfExSAPI .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.4 |
jnxoptIfODUkTNimTraceIdentifierAcceptedThe actual trace identifier accepted. The value of
this object is unspecified if jnxoptIfODUkTNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if jnxoptIfODUkTNimRowStatus has any value other
than active(1).ro JnxoptIfAcTI .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.5 |
jnxoptIfODUkTNimTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.rw JnxoptIfTIMDetMode .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.6 |
jnxoptIfODUkTNimTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.7 |
jnxoptIfODUkTNimDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to jnxoptIfODUkTNimDEGThr.rw JnxoptIfDEGThr UNITS "percentage" .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.8 |
jnxoptIfODUkTNimDEGMIndicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if jnxoptIfODUkTNimDEGM
consecutive bad PM Seconds are detected.rw JnxoptIfDEGM .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.9 |
jnxoptIfODUkTNimCurrentStatusIndicates the defect condition of the entity, if any.
The value of this object is unspecified if
jnxoptIfODUkTNimRowStatus has any value other than
active(1).ro Bits .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.10 |
jnxoptIfODUkTNimRowStatusThis columnar object is used for creating and deleting a
conceptual row of the jnxoptIfODUkTNim config table.
It is used to model the addTCM and removeTCM operations of an
ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection
monitoring as defined in ITU-T G.874.1.
Setting RowStatus to createAndGo or createAndWait implies addTCM.
Setting RowStatus to destroy implies removeTCM.
Successful addition/removal of Nim TCM will result in updating
the jnxoptIfODUkPositionSeqCurrentSize variable and the
jnxoptIfODUkPositionSeqTable table of the associated ODUk entry
in the jnxoptIfODUkConfigTable.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2636.3.73.1.1.9.2.1.11 |
jnxoptIfConfs OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.2 |
jnxoptIfGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.2.1 |
jnxoptIfCompl OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.73.1.2.2 |