ITOUCH-TRAP-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for ITOUCH-TRAP-MIB.
22
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
22 total| Object Name |
|---|
xTrap OBJECT IDENTIFIER .1.3.6.1.4.1.33.48 |
resourceLacksIndication that the system incremented the
corresponding value of resLacks. The variable is resType
FROM ITOUCH-SYSTEM-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.9 |
repeaterRedundancyA new path becomes active within a redundancy group. The
variables are repeaterRedundancyGroupGroupIndex,
repeaterRedundancyGroupOperPath FROM ITOUCH-REPEATER-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.12 |
accessViolatedAccess violation by connected system with Ethernet
address not allowed by repeaterPortAccessTable and
repeaterPortAccessAction. The variable is repeaterPortIndex
FROM ITOUCH-REPEATER-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.14 |
portIntegrityLossThis port has lost link integrity. The variables are
repeaterPortIndex, repeaterPortGroupIndex
FROM ITOUCH-REPEATER-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.15 |
iTouchRmonAlarmThe SNMP trap that is generated when xRmonTrapType
is set to iTouchFormat(2). These traps, like the
RMON standardFormat(1) traps, occur when an alarm
variable crosses its rising or falling threshold
and generates an event configured to send SNMP traps.
The format of the DisplayString embodied by the
trap PDU is identical to that of mbLogDescription.
The actual object identifier is not significant.
The variable is mbLogDescription FROM ITOUCH-RMON-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.17 |
memoryCardSlotChangeIndication that the card has been added or removed. The
deviceIndex from ITOUCH-BOOT-SERVER-MIB may be included
as a variable in the trap. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.18 |
lb2ChassisCardSlotChangeIndication that the card has been added or removed. The
variable is slotIndex FROM ITOUCH-CHASSIS-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.19 |
circuitDialTimeIndication that a dialed circuit has reached a threshhold
for the maximum number of minutes that a dialed call may
remain active. The variable is ifIndex FROM RFC1213-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.20 |
circuitPerDialTimeIndication that a dialed circuit has reached a threshhold
for the maximum number of minutes that a circuit may be
active with dialed calls within a given period.
The variable is ifIndex FROM RFC1213-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.21 |
circuitPerDialAttemptIndication that a dialed circuit has reached a threshhold
for the maximum number of dial attempts that a circuit
may make for a given period.
The variable is ifIndex FROM RFC1213-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.22 |
fddiPcmStatusChangeA fddi port status has changed.
The variable is fddimibPORTPCMState FROM FDDI-SMT73-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.23 |
fddiSMTCFStateFailureA fddi station detects that the link is disabled or broken.
The variable is fddimibSMTCFState FROM FDDI-SMT73-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.26 |
sysLoginAuthenticationFailedIndicates when and where a user attempted and failed to
access the system. The variables are sysLoginAuthFailureTrapType,
sysLoginAuthTrapIdentity FROM ITOUCH-SYSTEM-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.28 |
sensorThresholdExceededIndication that the temperature or humidity exceeded a threshhold and
the value of the currrent temperature or humidity. Either the
basicTemperatureValue or basicHumidityValue is included
as a variable in the trap to indicate which sensor exceeded its
threshold. These variables are FROM ITOUCH-CHARACTER-MIB. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.29 |
contactClosureChangeIndication that the contact closure transitioned to open or closed. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.30 |
powerAlarmFuseAIndicates that a fuse from bank A tripped its breaker, or that
it went operational. However, it is unlikely that a trap would
be issued when the fuse starts working. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.31 |
powerAlarmFuseBIndicates that a fuse from bank B tripped its breaker, or that
it went operational. However, it is unlikely that a trap would
be issued when the fuse starts working. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.32 |
powerAlarmSupplyAIndicates that power supply A lost or regained power.
However, it is unlikely that a trap would be issued when the
power comes on. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.33 |
powerAlarmSupplyBIndicates that power supply B lost or regained power.
However, it is unlikely that a trap would be issued when the
power comes on. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.34 |
portInputSignalChangedIndicates that an input signal on a port has transitioned to
the state indicated in the variable rs232InSigState. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.35 |
portOutputSignalChangedIndicates that an output signal on a port has transitioned to
the state indicated in the variable rs232OutSigState. TRAP-TYPE .1.3.6.1.4.1.52642.1.1.2.0.36 |