Home/Catalog/ITOUCH-TRAP-MIB

ITOUCH-TRAP-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ITOUCH-TRAP-MIB.

22
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

22 total
Object Name
xTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.33.48
resourceLacksIndication that the system incremented the corresponding value of resLacks. The variable is resType FROM ITOUCH-SYSTEM-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.9
repeaterRedundancyA new path becomes active within a redundancy group. The variables are repeaterRedundancyGroupGroupIndex, repeaterRedundancyGroupOperPath FROM ITOUCH-REPEATER-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.12
accessViolatedAccess violation by connected system with Ethernet address not allowed by repeaterPortAccessTable and repeaterPortAccessAction. The variable is repeaterPortIndex FROM ITOUCH-REPEATER-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.14
portIntegrityLossThis port has lost link integrity. The variables are repeaterPortIndex, repeaterPortGroupIndex FROM ITOUCH-REPEATER-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.15
iTouchRmonAlarmThe SNMP trap that is generated when xRmonTrapType is set to iTouchFormat(2). These traps, like the RMON standardFormat(1) traps, occur when an alarm variable crosses its rising or falling threshold and generates an event configured to send SNMP traps. The format of the DisplayString embodied by the trap PDU is identical to that of mbLogDescription. The actual object identifier is not significant. The variable is mbLogDescription FROM ITOUCH-RMON-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.17
memoryCardSlotChangeIndication that the card has been added or removed. The deviceIndex from ITOUCH-BOOT-SERVER-MIB may be included as a variable in the trap.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.18
lb2ChassisCardSlotChangeIndication that the card has been added or removed. The variable is slotIndex FROM ITOUCH-CHASSIS-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.19
circuitDialTimeIndication that a dialed circuit has reached a threshhold for the maximum number of minutes that a dialed call may remain active. The variable is ifIndex FROM RFC1213-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.20
circuitPerDialTimeIndication that a dialed circuit has reached a threshhold for the maximum number of minutes that a circuit may be active with dialed calls within a given period. The variable is ifIndex FROM RFC1213-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.21
circuitPerDialAttemptIndication that a dialed circuit has reached a threshhold for the maximum number of dial attempts that a circuit may make for a given period. The variable is ifIndex FROM RFC1213-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.22
fddiPcmStatusChangeA fddi port status has changed. The variable is fddimibPORTPCMState FROM FDDI-SMT73-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.23
fddiSMTCFStateFailureA fddi station detects that the link is disabled or broken. The variable is fddimibSMTCFState FROM FDDI-SMT73-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.26
sysLoginAuthenticationFailedIndicates when and where a user attempted and failed to access the system. The variables are sysLoginAuthFailureTrapType, sysLoginAuthTrapIdentity FROM ITOUCH-SYSTEM-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.28
sensorThresholdExceededIndication that the temperature or humidity exceeded a threshhold and the value of the currrent temperature or humidity. Either the basicTemperatureValue or basicHumidityValue is included as a variable in the trap to indicate which sensor exceeded its threshold. These variables are FROM ITOUCH-CHARACTER-MIB.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.29
contactClosureChangeIndication that the contact closure transitioned to open or closed.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.30
powerAlarmFuseAIndicates that a fuse from bank A tripped its breaker, or that it went operational. However, it is unlikely that a trap would be issued when the fuse starts working.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.31
powerAlarmFuseBIndicates that a fuse from bank B tripped its breaker, or that it went operational. However, it is unlikely that a trap would be issued when the fuse starts working.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.32
powerAlarmSupplyAIndicates that power supply A lost or regained power. However, it is unlikely that a trap would be issued when the power comes on.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.33
powerAlarmSupplyBIndicates that power supply B lost or regained power. However, it is unlikely that a trap would be issued when the power comes on.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.34
portInputSignalChangedIndicates that an input signal on a port has transitioned to the state indicated in the variable rs232InSigState.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.35
portOutputSignalChangedIndicates that an output signal on a port has transitioned to the state indicated in the variable rs232OutSigState.
TRAP-TYPE
.1.3.6.1.4.1.52642.1.1.2.0.36