IPL-TRAP-MIB
AI MIB Summary
The IPL-TRAP-MIB module facilitates Operations, Administration, and Maintenance (OA&M) for IP Line cards by defining specific trap notifications and management objects to monitor card status, fault conditions, and operational state changes.
This MIB contains data for the OA&M of IP Line card.
Main OID:
ipltrapmib.1.3.6.1.4.1.562.3.11.50
24
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
24 total| Object Name |
|---|
nt OBJECT IDENTIFIER .1.3.6.1.4.1.562 |
meridian OBJECT IDENTIFIER .1.3.6.1.4.1.562.3 |
itg OBJECT IDENTIFIER .1.3.6.1.4.1.562.3.11 |
iplmib OBJECT IDENTIFIER .1.3.6.1.4.1.562.3.11.5 |
fm-Info OBJECT IDENTIFIER .1.3.6.1.4.1.562.3.11.5.4 |
fmItgAlarmTraps OBJECT IDENTIFIER .1.3.6.1.4.1.562.3.11.5.4.1 |
criticalAlarmThis trap is used to provide a real time indication
of a critical alarm condition. The variables listed
in VARIABLES clause are defined in `fmAlarmInfo'
group are present in all critical alarms. TRAP-TYPE .1.3.6.1.4.1.562.3.11.5.4.1.0.1 |
majorAlarmThis trap is used to provide a real time indication
of a major alarm condition. The variables listed in
VARIABLES clause are defined in `fmAlarmInfo' group
are present in all major alarms. TRAP-TYPE .1.3.6.1.4.1.562.3.11.5.4.1.0.2 |
minorAlarmThis trap is used to provide a real time indication
of a minor alarm condition. The variables listed in
VARIABLES clause are defined in `fmAlarmInfo' group
are present in all minor alarms. TRAP-TYPE .1.3.6.1.4.1.562.3.11.5.4.1.0.3 |
warningAlarmThis trap is used to provide a real time indication
of a warning alarm condition. The variables listed in
VARIABLES clause are defined in `fmAlarmInfo' group
are present in all warning alarms. TRAP-TYPE .1.3.6.1.4.1.562.3.11.5.4.1.0.4 |
clearedAlarmThis trap is used to provide a real time indication
of a cleared alarm. The variables listed in VARIABLES
clause are defined in `fmAlarmInfo' group are present
in all cleared alarms. TRAP-TYPE .1.3.6.1.4.1.562.3.11.5.4.1.0.5 |
indeterminateAlarmThis trap is used to provide a real time indication
of a indeterminate alarm condition. The variables
listed in VARIABLES clause are defined in
`fmAlarmInfo' group are present in all
indeterminate alarms. TRAP-TYPE .1.3.6.1.4.1.562.3.11.5.4.1.0.6 |
fmAlarmInfo OBJECT IDENTIFIER .1.3.6.1.4.1.562.3.11.5.4.1.7 |
componentRowPointerA pointer to the RowStatus variable of the component
emitting the alarm, on a system where a component is
generally a table entry. RowPointer (SNMPv2-TC) .1.3.6.1.4.1.562.3.11.5.4.1.7.1 |
componentNameThis convention is used where each component can be
uniquely referenced by a type and instance name
(at the console interface also). The textual content
of this may be limited to the string representation
of the OID. DisplayString (SNMPv2-TC) .1.3.6.1.4.1.562.3.11.5.4.1.7.2 |
eventTimeThe date and time at which the alarmed event occurred. DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.562.3.11.5.4.1.7.3 |
activeListStatusThe active alarm list status. This may be used by the
Manager to add (on receiving a set) and delete (on
receiving a clear) alarms from the alarm display. Enumeration .1.3.6.1.4.1.562.3.11.5.4.1.7.4 |
severityThe severity of the alarm which should indicate what
priority should be given for fixing this problem. All
values are OSI-defined; refer to CCITT X.733/ISO 10164-4
for a more complete description. AlarmSeverity .1.3.6.1.4.1.562.3.11.5.4.1.7.5 |
alarmTypeThe alarm type field as defined by OSI which is used
to indicate a broad category of what is wrong. The
first 6 values are OSI-defined; refer to CCITT X.733/ISO
10164-4 (for the first 5) and CCITT X.736/ISO 10164-4
(for the last) for a more complete description. The
value 'operator' is used when an alarm is issued due
to an operator command. The values 'debug' and 'unknown'
are for compatibility with older switches and are used
for debugging alarms and for those which do not fit
any of the above, respectively. AlarmType .1.3.6.1.4.1.562.3.11.5.4.1.7.6 |
probableCauseThe probable cause for the alarm which usually
qualifies the Alarm Type field. Most values are
OSI-defined; refer to CCITT X.733 and X.736
(ISO 10164-4 and 10164-7) for a more complete
description. INTEGER { -- Start of OSI-defined values -- (see X.733/ ISO 10165-3) lossOfSignal(0), lossOfFrame(1), framingError(2), localTransmissionError(3), remoteTransmissionError(4), callEstablishmentError(5), degradedSignal(6), commSubsystemFailure(7), commProtocolError(8), lanError(9), dteDceInterfaceError(10), responseTimeExcessive(20), queueSizeExceeded(21), bandwidthReduced(22), retransmissionRateReduced(23), thresholdCrossed(24), performanceDegraded(25), congestion(26), atOrNearCapacity(27), storageCapacityProblem(40), versionMismatch(41), corruptData(42), cpuCyclesLimitExceeded(43), softwareError(44), softwareProgramError(45), softwareProgramTermination(46), fileError(47), outOfMemory(48), underlyingResourceUnavail(49), applicationSubsystemFailure(50), configurationError(51), powerProblem(60), timingProblem(61), processorProblem(62), datasetModemError(63), multiplexorProblem(64), receiverFailure(65), transmitterFailure(66), outputDeviceError(67), inputDeviceError(68), ioDeviceError(69), equipmentFailure(70), adapterError(71), -- OSI-defined values continued (see X.736) duplicateInfo(80), infoMissing(81), infoModification(82), infoOutOfSequence(83), unexpectedInfo(84), denialOfService(90), outOfService(91), proceduralError(92), otherOperational(93), cableTamper(100), intrusionDetection(101), otherPhysical(102), authenticationFailure(110), breachOfConfidence(111), nonRepudiationFailure(112), unauthorized .1.3.6.1.4.1.562.3.11.5.4.1.7.7 |
ntpIndexAn 8-digit code which is an index into an NTP to
provide more description of the alarm and possible
actions to take. The first 4 digits indicate a 'group'
of alarms (belonging to a particular subsystem or
component, etc.). The last 4 digits are a subindex
arbitrarily assigned by the application which is
responsible for them. DisplayString .1.3.6.1.4.1.562.3.11.5.4.1.7.8 |
commentDataAdditional textual information for the network
operator to use. It contains only ASCII characters.
Note: The total number of bytes in commentData,
operatorData and internalData may not exceed 750 bytes. DisplayString .1.3.6.1.4.1.562.3.11.5.4.1.7.9 |
ipltrapmibThis MIB contains data for the OA&M of IP Line card. MODULE-IDENTITY .1.3.6.1.4.1.562.3.11.50 |
IMPORTSThis MIB contains data for the OA&M of IP Line card. Unknown .1.3.6.1.4.1.562.3.11.50 |