INFORMANT-MBM
AI MIB Summary
INFORMANT-MBM defines the standard Management Information Base for Informant's MBM (Mobile Broadband Manager) hardware and software, enabling the monitoring of mobile broadband session states, interface statistics, and device health metrics. This module facilitates the collection of operational data such as active user counts, link status, and throughput counters for Informant's cellular gateway and router platforms.
The MIB module for informant standard entities.
Main OID:
motherBoardMonitor.1.3.6.1.4.1.9600.1.10
22
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
22 total| Object Name |
|---|
motherBoardMonitorThe MIB module for informant standard entities. MODULE-IDENTITY .1.3.6.1.4.1.9600.1.10 |
mbmBusTypeNonero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9600.1.10.1 |
mbmPathMBM pathro DisplayString .1.3.6.1.4.1.9600.1.10.2 |
mbmSmbNameNice name for SMBusro DisplayString .1.3.6.1.4.1.9600.1.10.3 |
mbmSmbTypeNonero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9600.1.10.4 |
mbmVersionMBM Version numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9600.1.10.5 |
mbmSensorTableThe (conceptual) table listing all the MBM sensors. SEQUENCE OF MbmSensorEntry .1.3.6.1.4.1.9600.1.10.6 |
mbmSensorEntryAn entry (conceptual row) in the mbmSensorTable. MbmSensorEntry .1.3.6.1.4.1.9600.1.10.6.1 |
mbmSensorIndexIndex for this sensorro Integer32 .1.3.6.1.4.1.9600.1.10.6.1.1 |
mbmSensorNameName of sensorro DisplayString .1.3.6.1.4.1.9600.1.10.6.1.2 |
mbmSensorTypeType of sensorro Enumeration .1.3.6.1.4.1.9600.1.10.6.1.3 |
mbmSensorReadoutTotal number of readoutro Integer32 .1.3.6.1.4.1.9600.1.10.6.1.4 |
mbmSensorCurrentICurrent value in integer formro Integer32 .1.3.6.1.4.1.9600.1.10.6.1.5 |
mbmSensorCurrentSCurrent value in string formro DisplayString .1.3.6.1.4.1.9600.1.10.6.1.6 |
mbmSensorLowILowest readout value in integer formro Integer32 .1.3.6.1.4.1.9600.1.10.6.1.7 |
mbmSensorLowSLowest readout value in string formro DisplayString .1.3.6.1.4.1.9600.1.10.6.1.8 |
mbmSensorHighIHighest readout value in integer formro Integer32 .1.3.6.1.4.1.9600.1.10.6.1.9 |
mbmSensorHighSHighest readout value in string formro DisplayString .1.3.6.1.4.1.9600.1.10.6.1.10 |
mbmSensorAlarm1Itemp & fan: low alarm; voltage: % off (integer form)ro Integer32 .1.3.6.1.4.1.9600.1.10.6.1.11 |
mbmSensorAlarm1Stemp & fan: low alarm; voltage: % off string form)ro DisplayString .1.3.6.1.4.1.9600.1.10.6.1.12 |
mbmSensorAlarm2Itemp: high alarm (integer form)ro Integer32 .1.3.6.1.4.1.9600.1.10.6.1.13 |
mbmSensorAlarm2Stemp: high alarm (string form)ro DisplayString .1.3.6.1.4.1.9600.1.10.6.1.14 |