Home/Catalog/IBM2260-OPT-MIB

IBM2260-OPT-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

61
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

61 total
Object Name
codex
OBJECT IDENTIFIER
.1.3.6.1.4.1.449
RFC1155-SMI
Unknown
.1.3.6.1.4.1.449
cdxProductSpecific
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2
cdx6500
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1
cdx6500Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2
cdx6500CfgProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1
cdx6500PCTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.1
cdx6500PPCTIBM2260PortTableA list of IBM2260 Port configuration entries.
SEQUENCE OF Cdx6500IBM2260ConfigEntry
.1.3.6.1.4.1.449.2.1.2.1.1.20
cdx6500PPCTIBM2260PortEntryAn IBM2260 Configuration Table entry. Each entry contains the configuration parameters for a single IBM2260 port.
Cdx6500IBM2260ConfigEntry
.1.3.6.1.4.1.449.2.1.2.1.1.20.1
cdx6500IBM2260CfgPortNumberThe port number corresponding to this port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.1
cdx6500IBM2260CfgPadTypeIndicates whether the port is functioning as a Terminal PAD (TPAD) or a Host PAD (HPAD).ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.2
cdx6500IBM2260CfgPortSpeedThis is the speed of the port in bits per second, when using internal clocking.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.3
cdx6500IBM2260CfgConnTypeSpecify the control signal handshake required for a connection to be made to this port: simp - simple, no control signals required. simpa - CTS follows RTS, but no control signals required.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.4
cdx6500IBM2260CfgNumDeviceSpecifies the number of IBM2260 stations on this line.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.5
cdx6500IBM2260CfgServiceTimerThe Service Timer specifies the interval of time in seconds between periodic servicing. Such servicing includes intervals between attempts to establish network connections, intervals between attempts in TPAD to poll terminals that previously failed to respond, and in HPAD this timer is also used to detect host inactivity (i.e. when the host stops polling the station(s)).ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.6
cdx6500IBM2260CfgThreshCtrIndicates number of consecutive errors that can occur before a station is considered down.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.7
cdx6500IBM2260CfgRespTimeoutSpecifies the amount of time in msec the PAD allows a terminal, printer or host to respond. As a result, the TPAD may re-transmit the previous message or abort the current procedure. The HPAD aborts the current procedure as though EOT was received, allowing this HPAD station to disconnect it's SVC if the host malfunctions. An HPAD with a response timeout shorter than the hosts ability to respond may result in Inbound Errors.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.8
cdx6500IBM2260CfgPortSubAddrCalls addressed to this node and with this subaddress will be routed to this port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.9
cdx6500IBM2260CfgPortOptSelect options on this IBM2260 port as follows: NONE - No option specified ORG - Originate calls from this port ACK - DSP End-to-End Acknowledgements are to be used Any combination of above specified by summing (e.g. ORG+ACK).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.10
cdx6500IBM2260CfgRestConnDestAll calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.11
cdx6500IBM2260CfgBillRecThis controls whether billing (accounting) records will be created for calls on this port.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.12
cdx6500IBM2260CfgElectricalInterfaceTypeSpecify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type Note: Changing this parameter requires manual settings on SWITCH1: Interface SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 V.24 ON ON ON ON ON OFF OFF OFF V.35,V.36,X.21 OFF OFF OFF OFF OFF ON ON ONro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.13
cdx6500IBM2260CfgV24ElectricalInterfaceOptionSpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signalro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.14
cdx6500IBM2260CfgHighSpeedElectricalInterfaceOptionSpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cablero
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.20.1.15
cdx6500PCTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.3
cdx6500SPCTIBM2260StationTableAll of the configuration parameters relevant to the IBM2260 Station table.
SEQUENCE OF Cdx6500SPCTIBM2260StationEntry
.1.3.6.1.4.1.449.2.1.2.1.3.6
cdx6500SPCTIBM2260StationEntryA row of IBM2260 station configuration parameters.
Cdx6500SPCTIBM2260StationEntry
.1.3.6.1.4.1.449.2.1.2.1.3.6.1
cdx6500IBM2260sCfgPortNumPort number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.6.1.1
cdx6500IBM2260sCfgStationNumStation number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.6.1.2
cdx6500IBM2260sTypesingle - configures a single station addressable by the ADDR1-ADDR2 address pair. group - configures a group of stations addressable by the ADDR1 address character, but ADDR2 is assumed to be 40H, 41H, 42H and 43H. This type is intended for support of DataTroll devices. NOTE: `group' Station should not be used when the BSC3270-IBM2260 protocol Interoperation is being used.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.6.1.3
cdx6500IBM2260sStationAddr1This is the first byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7F;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.1.3.6.1.4
cdx6500IBM2260sStationAddr2This is the second byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7Fro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.1.3.6.1.5
cdx6500IBM2260sCallMnemThis mnemonic name is used if this port is configured for originating connection requests.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.1.3.6.1.6
cdx6500IBM2260sStationEnableThis parameter is used to disable/enable a station.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.6.1.7
cdx6500Statistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3
cdx6500StatProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1
cdx6500PSTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.1
cdx6500PPSTIBM2260PortTableA list of IBM2260 Port statistics.
SEQUENCE OF Cdx6500PPSTIBM2260PortEntry
.1.3.6.1.4.1.449.2.1.3.1.1.19
cdx6500PPSTIBM2260PortEntryAn IBM2260 Statistics Table entry. Each entry contains the statistics for a single IBM2260 port.
Cdx6500PPSTIBM2260PortEntry
.1.3.6.1.4.1.449.2.1.3.1.1.19.1
cdx6500IBM2260StatPortNumberPhysical port numberro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.1
cdx6500IBM2260StatPortStatusOperational Status of the port. The different operational statuses are: UP : At least 1 station is responding to polls. DOWN : None of the stations are responding to polls. DISABLED : The port is disabled by the user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.2
cdx6500IBM2260StatPortStateCurrent State of this port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.3
cdx6500IBM2260StatPortSpeedThe measured port speed in bits per second.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.4
cdx6500IBM2260StatPortUtilinThe amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive and transmit utilization.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.5
cdx6500IBM2260StatPortUtilOutThe amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive and transmit utilization.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.6
cdx6500IBM2260StatParityErrorsThe number of character parity errors counted by the I/O driver.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.7
cdx6500IBM2260StatOverrunErrorsThe number of received character overruns counted by the I/O driver.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.8
cdx6500IBM2260StatFramingErrorsThe number of asynchronous chracters received which violated the character framing of start and stop bits. Note, this statistic is only valid if the port is configured for ASYNC line interface.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.9
cdx6500IBM2260StatBCCErrorsThe number of BCC errors counted by the I/O driver.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.10
cdx6500IBM2260StatNoResponseThe number of times the response timer has expired.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.11
cdx6500IBM2260StatCharInTotalTotal number of chracters received to present.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.12
cdx6500IBM2260StatCharOutTotalTotal number of chracters transmitted to present.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.13
cdx6500IBM2260StatCharInSecondAverage number of characters received to present.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.14
cdx6500IBM2260StatCharOutSecondAverage number of characters transmitted to present.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.15
cdx6500IBM2260StatPosAckInNumber of ACKs received.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.16
cdx6500IBM2260StatPosAckOutNumber of ACKs transmitted.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.17
cdx6500IBM2260StatNegAckInNumber of NAKs received.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.18
cdx6500IBM2260StatNegAckOutNumber of NAKs transmitted.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.19
cdx6500IBM2260StatMsgRetranNumber of messages retransmitted due to NAKs or timeouts to present.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.19.1.20
cdx6500PSTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.3
cdx6500Controls
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4
IBM2260-OPT-MIB - SNMP MIB Reference | MIBs Explorer