Home/Catalog/HPOV-NNM-MIB

HPOV-NNM-MIB

AI MIB Summary

The HPOV-NNM-MIB provides the OID namespace and trap definitions for HP OpenView Network Node Manager to monitor network topology, node availability, and link state changes. It functions as the primary interface for receiving SNMPv1 trap notifications regarding network events and device status within the HP OpenView management ecosystem.

General management information used within the HP OpenView Network Node Manager product. This object identifier also serves as the OpenView Enterprise ID for SNMPv1 Traps.
Main OID:
hpOpenView.1.3.6.1.4.1.11.2.17.1
25
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

25 total
Object Name
hp
OBJECT IDENTIFIER
.1.3.6.1.4.1.11
nm
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2
openView
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.17
hpOpenViewGeneral management information used within the HP OpenView Network Node Manager product. This object identifier also serves as the OpenView Enterprise ID for SNMPv1 Traps.
MODULE-IDENTITY
.1.3.6.1.4.1.11.2.17.1
hpOVNNMTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.17.1.0
hpOVMessageTrapThis special event can be generated by a user to display an event message in the event browser. It assumes the message is in the third variable. To send a message with a popup notification, use the OV_Popup_Message event. On UNIX, see the trapd.conf(4) manpage for a discussion on how to set up the parameters to send this event, and a description of the parameters. On Windows, see the trapd.conf reference page in the help file. The data passed with the event is openViewSourceId: The ID of application sending the event openViewSourceName: The source of the event, if available openViewData: The string to display openViewSeverity: The severity of the event On UNIX, see the trapd.conf(4) manpage for complete details. On Windows, see the trapd.conf reference page in the help file.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11.2.17.1.0.58916872
openViewTrapVars
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.17.2
openViewSourceIdThe identifier of the software generating the trap/event. This number is used by HP OpenView software when it sends an event to the OpenView event system. It identifies which software component sent the event.ro
INTEGER -- Should be an ENUM
.1.3.6.1.4.1.11.2.17.2.1
openViewSourceNameThe source of the event (may not be the machine upon which the event was generated). This string is used by HP OpenView software when it sends an event. It identifies for which node the event is generated.ro
OVTextString
.1.3.6.1.4.1.11.2.17.2.2
openViewObjectIdThe OpenView Windows object identifier associated with the source of the trap/event.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.3
openViewDataAny miscellaneous data sent with an OpenView trap/event.ro
OCTET STRING
.1.3.6.1.4.1.11.2.17.2.4
openViewSeverityThe OpenView event severity associated with the trap/event.ro
OVTextString
.1.3.6.1.4.1.11.2.17.2.5
openViewCategoryThe OpenView event category associated with the trap/event.ro
OVTextString
.1.3.6.1.4.1.11.2.17.2.6
openViewFilterThe event filter for an application connecting to the OpenView event system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.7
openViewEntityThe entity (string name) of an application connecting to the OpenView event system.ro
OVTextString
.1.3.6.1.4.1.11.2.17.2.8
openViewAddressThe IP address of the node from where an application is connecting to the OpenView event system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.9
openViewPidThe process ID of an application connecting to the OpenView event system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.10
openViewCmipManagedObjectClassA cmisEventReport managedObjectClass. Only valid when running with the HP OpenView DM product.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.11
openViewCmipEventTimeA cmisEventReport eventTime. Only valid when running with the HP OpenView DM product.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.12
openViewCmipEventTypeA cmisEventReport eventType. Only valid when running with the HP OpenView DM product.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.13
openViewCmipEventInfoA cmisEventReport eventInfo. Only valid when running with the HP OpenView DM product.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.14
openViewCmipManagedObjectInstanceIdA cmisEventReport managedObjectInstance. Only valid when running with the HP OpenView DM product.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.15
openViewEventUUIDAn OpenView Event UUID which uniquely identifies an event.ro
OCTET STRING
.1.3.6.1.4.1.11.2.17.2.16
openViewEcsCorrelateEvUUIDIf an OpenView event contains this var-bind, it indicates to the Event Correlation System that the event should be correlated with the event whose UUID is the value of this var-bind. If the var-bind is missing or has a zero length value, then no event correlation occurs.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.17
openViewEcsNodeImportanceIf an OpenView event contains this var-bind, it indicates to the Event Correlation System the importance of the node from an event correlation perspective. In situations where the ECS system would normally suppress an event, it may choose not to suppress it if the node is very important (e.g. an important server node). The integral value of this MIB object may evolve over time. For now, non-integral values are invalid, a value of zero indicates that the node is a regular node and a non-zero value indicates that the node is an important node.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.17.2.18