Home/Catalog/HPN-ICF-TE-TUNNEL-MIB

HPN-ICF-TE-TUNNEL-MIB

This MIB contains managed object definitions for the Multiprotocol Label Switching (MPLS) Te Tunnel.
Main OID:
hpnicfTeTunnel.1.3.6.1.4.1.11.2.14.11.15.2.115
49
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

49 total
Object Name
hpnicfTeTunnelThis MIB contains managed object definitions for the Multiprotocol Label Switching (MPLS) Te Tunnel.
MODULE-IDENTITY
.1.3.6.1.4.1.11.2.14.11.15.2.115
hpnicfTeTunnelScalars
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.115.1
hpnicfTeTunnelMaxTunnelIndexThe max value of tunnel id is permitted configure on the device.ro
MplsTunnelIndex (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.1.1
hpnicfTeTunnelObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.115.2
hpnicfTeTunnelStaticCrlspTableThis table contains information for static-crlsp, and through this to get detail information about this static-crlsp. Only support transit LSR and egress LSR.
SEQUENCE OF HpnicfTeTunnelStaticCrlspEntry
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.1
hpnicfTeTunnelStaticCrlspEntryThe entry in this table describes static-crlsp information.
HpnicfTeTunnelStaticCrlspEntry
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.1.1
hpnicfTeTunnelStaticCrlspInLabelThis is unique label value that manualy assigned. Uniquely identifies a static-crlsp. Managers should use this to obtain detail static-crlsp information.
MplsLabel (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.1.1.1
hpnicfTeTunnelStaticCrlspNameThe unique name assigned to the static-crlsp.ro
OCTET STRING
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.1.1.2
hpnicfTeTunnelStaticCrlspStatusIndicates the actual status of this static-crlsp, The value must be up when the static-crlsp status is up and the value must be down when the static-crlsp status is down.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.1.1.3
hpnicfTeTunnelStaticCrlspRoleThis value indicate the role of this static-crlsp. This value must be transit at transit point of the tunnel, and tail at terminating point of the tunnel.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.1.1.4
hpnicfTeTunnelStaticCrlspXCPointerThis pointer unique identify a row of mplsXCTable. This value should be zeroDotZero when the static-crlsp is down. The mplsXCTable identifies the segments that compose this tunnel, their characteristics, and relationships to each other.ro
RowPointer (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.1.1.5
hpnicfTeTunnelCoTableThis table contains information for Co-routed reverse crlsp and infomation of Co-routed bidirectional Tunnel Interface. If hpnicfCorouteTunnelLspInstance is zero, to obtain infomation of Co-routed bidirectional Tunnel Interface, otherwise to obtain Co-routed reverse crlsp infomation.
SEQUENCE OF HpnicfTeTunnelCoEntry
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2
hpnicfTeTunnelCoEntryThe entry in this table describes Co-routed infomation of bidirectional Tunnel Interface and reserver lsp information.
HpnicfTeTunnelCoEntry
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1
hpnicfTeTunnelCoIndexUniquely identifies a set of tunnel instances between a pair of ingress and egress LSRs that specified at originating point. This value should be equal to the value signaled in the Tunnel Id of the Session object.
MplsTunnelIndex (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1.1
hpnicfTeTunnelCoLspInstanceWhen obtain infomation of Co-routed bidirectional Tunnel Interface, this vlaue should be zero. And this value must be LspID to obtain reverse crlsp information. Values greater than 0, but less than or equal to 65535, should be useless.
MplsTunnelInstanceIndex (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1.2
hpnicfTeTunnelCoIngressLSRIdIdentity the ingress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of originating endpoint.
MplsExtendedTunnelId (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1.3
hpnicfTeTunnelCoEgressLSRIdIdentity of the egress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of terminating point.
MplsExtendedTunnelId (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1.4
hpnicfTeTunnelCoBiModeThis vlaue indicated the bidirection mode of tunnel interface. The valuemust be coroutedActive at the originating point of the tunnel and coroutedPassive at the terminating point.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1.5
hpnicfTeTunnelCoReverseLspInstanceThis value indicated the reverse lsp instance, and should be equal to obverse lsp instance.ro
MplsTunnelInstanceIndex (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1.6
hpnicfTeTunnelCoReverseLspXCPointerThis pointer unique index to mplsXCTable of the reverse lsp. The mplsXCTable identifies the segments that compose this tunnel, their characteristics, and relationships to each other. A value of zeroDotZero indicate that there is no crlsp assigned to this.ro
RowPointer (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.2.1.7
hpnicfTeTunnelPsTableThis table defines some objects for managers to obtain TE tunnel Protection Switching group current status information.
SEQUENCE OF HpnicfTeTunnelPsEntry
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3
hpnicfTeTunnelPsEntryThe entry in this table describes TE tunnel Protection Switching group infromation.
HpnicfTeTunnelPsEntry
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1
hpnicfTeTunnelPsIndexUniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of work tunnel instance.
MplsTunnelIndex (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.1
hpnicfTeTunnelPsIngressLSRIdIdentity the ingress LSR associated with work tunnel instance.
MplsExtendedTunnelId (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.2
hpnicfTeTunnelPsEgressLSRIdIdentity of the egress LSR associated with work tunnel instance.
MplsExtendedTunnelId (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.3
hpnicfTeTunnelPsProtectIndexUniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of TE tunnel Protection Switching group instance.ro
MplsTunnelIndex (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.4
hpnicfTeTunnelPsProtectIngressLSRIdIdentity the ingress LSR associated with TE tunnel Protection Switching group instance.ro
MplsExtendedTunnelId (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.5
hpnicfTeTunnelPsProtectEgressLSRIdIdentity of the egress LSR associated with TE tunnel Protection Switching group instance.ro
MplsExtendedTunnelId (MPLS-TC-STD-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.6
hpnicfTeTunnelPsProtectTypeThis value indicated TE tunnel Protection Switching group type. The default value is oneToOne.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.7
hpnicfTeTunnelPsRevertiveModeThis value indicated protect switch mode. The value must be revertive or nonRevertive, default value is revertive.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.8
hpnicfTeTunnelPsWtrTimeThe cycle time that switch to protect tunnel.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.9
hpnicfTeTunnelPsHoldOffTimeThis value is switchback delay time. When detected the work path fault, switch to protect path after this time.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.10
hpnicfTeTunnelPsSwitchModeThis value indicated TE tunnel Protection Switching group switch mode.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.11
hpnicfTeTunnelPsWorkPathStatusThis value indicates work path status. none, noDefect, inDefect will be used.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.12
hpnicfTeTunnelPsProtectPathStatusThis value indicates protect path status. none, noDefect, inDefect(3) will be used.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.13
hpnicfTeTunnelPsSwitchResultThis value indicated current using path is work path or protect path.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.115.2.3.1.14
hpnicfTeTunnelNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.115.3
hpnicfTeTunnelNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.115.3.0
hpnicfTeTunnelPsSwitchWtoPThis notification is generated when protect workgroup switch from work tunnel to protect tunnel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11.2.14.11.15.2.115.3.0.1
hpnicfTeTunnelPsSwitchPtoWThis notification is generated when protect workgroup switch from protect tunnel to work tunnel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11.2.14.11.15.2.115.3.0.2
hpnicfTeTunnelConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.115.4
hpnicfTeTunnelCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.1
hpnicfTeTunnelComplianceThe compliance statement for SNMP.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.1.1
hpnicfTeTunnelGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.2
hpnicfTeTunnelNotificationsGroupThis group contains MPLS Te Tunnel traps.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.2.1
hpnicfTeTunnelScalarsGroupScalar object needed to implement MPLS te tunnels.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.2.2
hpnicfTeTunnelStaticCrlspGroupObjects for quering static-crlsp information.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.2.3
hpnicfTeTunnelCorouteGroupObjects for quering Co-routed reverse crlsp information.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.2.4
hpnicfTeTunnelPsGroupObjects for quering protect workgroup information.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.115.4.2.5
HPN-ICF-TE-TUNNEL-MIB - SNMP MIB Reference | MIBs Explorer