HPN-ICF-CONFIG-MAN-MIB

AI MIB Summary

The HPN-ICF-CONFIG-MAN-MIB provides SNMP objects to monitor and modify the system configuration data and model representations for HPE Aruba Networking (formerly HP) Intelligent ClearFiber (ICF) switches and associated peripheral devices. It enables the retrieval and manipulation of configuration parameters across the network infrastructure without imposing specific data constraints on the managed objects.

This MIB contains objects for managing the system configuration. It contains the model used to represent configuration data that exists elsewhere in the system and in peripheral devices. There are no constraints on this MIB.
Main OID:
hpnicfConfig.1.3.6.1.4.1.11.2.14.11.15.2.4
83
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

83 total
Object Name
hpnicfConfigThis MIB contains objects for managing the system configuration. It contains the model used to represent configuration data that exists elsewhere in the system and in peripheral devices. There are no constraints on this MIB.
MODULE-IDENTITY
.1.3.6.1.4.1.11.2.14.11.15.2.4
hpnicfConfigManObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.1
hpnicfCfgLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1
hpnicfCfgRunModifiedLastThe object records the value of sysUpTime when the current configuration running in the system was last modified. The value will be changed immediately after system detects the current configuration has been changed.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.1
hpnicfCfgRunSavedLastThe object records the value of sysUpTime when the current configuration running in the system was last saved. If the value of the object is smaller than hpnicfCfgRunModifiedLast, the current configuration has been modified but not saved.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.2
hpnicfCfgStartModifiedLastThe object records the value of sysUpTime when the saved configuration used currently was last modified. It may have been modified by a save of the current configuration running in the system or other methods such as copy.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.3
hpnicfCfgLogLimitedEntriesThe object shows the maximum number of rows in hpnicfCfgLogTable. The value supported by the system is 10.ro
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.4
hpnicfCfgLogDeletedEntriesThe total number of rows deleted from hpnicfCfgLogTable.ro
Counter32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.5
hpnicfCfgLogWantBackupDecide whether to backup the value of objects about hpnicfCfgLog.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.6
hpnicfCfgLogTableTable for logging configuration operation in device.
SEQUENCE OF HpnicfCfgLogEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7
hpnicfCfgLogEntryInformation of the entry.
HpnicfCfgLogEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1
hpnicfCfgLogIndexIndex of the table beginning from 1.
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.1
hpnicfCfgLogTimeSpecify the sysUpTime when the config log was generated.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.2
hpnicfCfgLogSrcCmdSpecify the source command which brought the log. Currently we provide the types of source: 1.cmdLine(1):configure log instigated by command line. 2.snmp(2):configure log instigated by snmp. 3.other(3):configure log instigated by other source unknown.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.3
hpnicfCfgLogSrcDataThe source of the configuration data event. erase erasing destination runningData operational data alive commandSource the command source itself startupData what the system will use next reboot local local NVRAM or flash netFtp FTP network transfer hotPlugging board is inserted or pulled out on linero
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.4
hpnicfCfgLogDesDataThe destination for the configuration data event. unknown unknown runningData operational data alive commandSource the command source itself startupData what the system will use next reboot local local NVRAM or flash netFtp FTP network transfer hotPlugging board is inserted or pulled out on linero
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.5
hpnicfCfgLogTerminalTypeSpecifies the terminal type. If hpnicfCfgLogSrcCmd is not 'cmdLine', use 'notApplicable'. The value list: notApplicable(1): no meaning at this time. unknown(2): unknown terminal type. console(3): console interface. terminal(4): generic terminal. virtual(5): virtual terminal such as telnet. auxiliary(6): auxiliary interface.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.6
hpnicfCfgLogTerminalUserThe name of logging user which is available when hpnicfCfgLogSrcCmd is 'cmdLine'. Other, a zero length string.ro
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.7
hpnicfCfgLogTerminalNumSpecifies the terminal number. If hpnicfCfgLogSrcCmd is not 'cmdLine', use '-1'ro
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.8
hpnicfCfgLogTerminalLocationThe location of logging user which is available when hpnicfCfgLogSrcCmd is 'cmdLine'. Other, a zero length string.ro
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.9
hpnicfCfgLogCmdSrcAddressThe address from which a request comes when the value of hpnicfCfgLogSrcCmd is 'snmp(2)'. The ip address of the remote system connected when the value of hpnicfCfgLogTerminalType is 'virtual'. Other, the value of 0.0.0.0. This object is replaced by hpnicfCfgLogCmdSrcAddrRev for it only support IPv4.rodeprecated
IpAddress
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.10
hpnicfCfgLogVirHostThe host name of remote system connected if hpnicfCfgLogTerminalType has the value of 'virtual'. Other, a zero length string.ro
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.11
hpnicfCfgLogUserNameThe user name used when hpnicfCfgLogSrcData or hpnicfCfgLogDesData has the value of 'netFtp'. Other, a zero length string.ro
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.12
hpnicfCfgLogServerAddressThe remote server address when hpnicfCfgLogSrcData or hpnicfCfgLogDesData has the value of 'netFtp'. Other, a value of 0.0.0.0. This object is replaced by hpnicfCfgLogServerAddrRev for it only support IPv4.rodeprecated
IpAddress
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.13
hpnicfCfgLogFileThe current configuration file name when hpnicfCfgLogSrcData has the value of 'netFtp',and hpnicfCfgLogDesData has the value of 'startupData'. Other, a zero length string.ro
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.14
hpnicfCfgLogCmdSrcAddrTypeThe type of IP address for the hpnicfCfgLogCmdSrcAddrRev.ro
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.15
hpnicfCfgLogCmdSrcAddrRevThe address from which a request comes when the value of hpnicfCfgLogSrcCmd is 'snmp(2)'. The ip address of the remote system connected when the value of hpnicfCfgLogTerminalType is 'virtual'. Other, the value of 0.0.0.0.ro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.16
hpnicfCfgLogCmdSrcAddrVPNNameThe VPN instance of this operation uses.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.17
hpnicfCfgLogServerAddrTypeThe type of IP address for the hpnicfCfgLogServerAddrRev.ro
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.18
hpnicfCfgLogServerAddrRevThe remote server address when hpnicfCfgLogSrcData or hpnicfCfgLogDesData has the value of 'netFtp'. Other, a value of 0.0.0.0.ro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.19
hpnicfCfgLogServerAddrVPNNameThe VPN instance of this operation uses.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.7.1.20
hpnicfCfgFirstTrapTimeTime when the first trap is sent.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.1.8
hpnicfCfgOperate
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2
hpnicfCfgOperateGlobalEntryLimitThe maximum number of copy entries that may be held in hpnicfCfgOperateTable. A particular setting does not guarantee that much data can be held.ro
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.1
hpnicfCfgOperateEntryAgeOutTimeThe number of minutes an unactive hpnicfCfgOperateEntry SHOULD be kept in the hpnicfCfgOperateTable before it is active. The object is a fator taken account of when it needs delete some rows make room in hpnicfCfgOperateTable.rw
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.2
hpnicfCfgOperateResultGlobalEntryLimitThe maximum number of copy entries that may be held in hpnicfCfgOperateResultTable. A particular setting does not guarantee that much data can be held.rw
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.3
hpnicfCfgOperateTableA table of config-operation requests.
SEQUENCE OF HpnicfCfgOperateEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4
hpnicfCfgOperateEntryAn operate request entry.
HpnicfCfgOperateEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1
hpnicfCfgOperateIndexThe unique index value of a row in this table.
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.1
hpnicfCfgOperateTypeSpecify the type of operation on configuration.rw
ConfigOperationType
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.2
hpnicfCfgOperateProtocolIf the value of hpnicfCfgOperateType is running2Net,net2Running,net2Startup or startup2net, this node specify the protocol to be used for file transfer . The default protocol is ftp if no protocol is specified. And for other value of hpnicfCfgOperateType , this object may be ignored by the implementation. when clusterftp or clustertftp is selected, the hpnicfCfgOperateServerAddress needn't be set, the server address can be acquired automatically, the value of hpnicfCfgOperateServerAddress is uncertain during operation. both member switch and commander switch can use them if they support HGMP v2.rw
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.3
hpnicfCfgOperateFileNameWhen the object of hpnicfCfgOperateType has the value of net2Startup, net2running or running2Net,the value must be specified. The file name may include the path if applicable. If the value of hpnicfCfgOperateType is net2Startup or net2running, this node specify the source file name of transfers.If the value of hpnicfCfgOperateType is running2Net , this node specify the destination file name of transfers. When hpnicfCfgOperateType has the value of startup2net,the object may not be created instead of using the file name of startup configuration file.rw
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.4
hpnicfCfgOperateServerAddressWhen the operation type is running2Net,net2Running,net2Startup or startup2net , the ip address of the ftp/tftp server from/to which to download/upload must be specified. Values of 0.0.0.0 or FF.FF.FF.FF are not permitted. This object is replaced by hpnicfCfgOperateSrvAddrRev for it only support IPv4.rwdeprecated
IpAddress
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.5
hpnicfCfgOperateUserNameWhen the operation type is running2Net,net2Running,net2Startup or startup2net , the user name for the ftp server from/to which to download/upload should be specified. The object must be created if hpnicfCfgOperateProtocol has the value of ftp.rw
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.6
hpnicfCfgOperateUserPasswordWhen the operation type is running2Net,net2Running,net2Startup or startup2net , the user password for the ftp server from/to which to download/upload should be specified. The object must be created if hpnicfCfgOperateProtocol has the value of ftp.rw
DisplayString
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.7
hpnicfCfgOperateEndNotificationSwitchSpecifies whether or not a notification should be issued on the completion of the operation.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.8
hpnicfCfgOperateRowStatusThe status of this table entry. When the status is active all the object's value in the entry is not allowed to modified.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.9
hpnicfCfgOperateServerPortWhen the operation type is running2Net, net2Running, net2Startup or startup2Net, this node is used for specifying the remote port number. If the value is 0 or not specified, the known port number will be used.rw
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.10
hpnicfCfgOperateSrvAddrTypeThe type of IP address for hpnicfCfgOperateSrvAddrRev.rw
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.11
hpnicfCfgOperateSrvAddrRevWhen the operation type is running2Net,net2Running,net2Startup or startup2net , the ip address of the ftp/tftp server from/to which to download/upload must be specified.rw
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.12
hpnicfCfgOperateSrvVPNNameThe VPN instance of this operation uses.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.4.1.13
hpnicfCfgOperateResultTableA table of config-operation requests result.
SEQUENCE OF HpnicfCfgOperateResultEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5
hpnicfCfgOperateResultEntryThe result entries of configuration operation requests.
HpnicfCfgOperateResultEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1
hpnicfCfgOperateResultIndexThe index of Table, which is an incremental integer. The maximum value of the node is 2147483647. The agent should wrap the value to 1 and flush all the existing entries when the maximum value is reached.
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1.1
hpnicfCfgOperateResultOptIndexThe operation index in the hpnicfCfgOperateTable.ro
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1.2
hpnicfCfgOperateResultOpTypeThe operation type in the hpnicfCfgOperateTable.ro
ConfigOperationType
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1.3
hpnicfCfgOperateStateThe operation state type in the hpnicfCfgOperateTable.ro
ConfigOperationStateType
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1.4
hpnicfCfgOperateTimeRecord the time taken for the operation. This object will be like a stopwatch, starting when the operation starts, and stopping when the operation completes.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1.5
hpnicfCfgOperateEndTimeThe value of sysUpTime when the configuration operation is finished.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1.6
hpnicfCfgOperFailReasonThe failure reasons of configuration operation.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.5.1.7
hpnicfCfgExecuteOperate
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6
hpnicfCfgExecuteOperateResultEntryLimitThe maximum number of ConfigOperationType entries that may be held in hpnicfCfgExecuteResultTable. A particular setting does not guarantee that much data can be held.rw
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.1
hpnicfCfgExecuteResultTableA table of configuration execute result.
SEQUENCE OF HpnicfCfgExecuteResultEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2
hpnicfCfgExecuteResultEntryThe result entries of configuration execute operation.
HpnicfCfgExecuteResultEntry
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2.1
hpnicfCfgExecuteResultIndexThe index of Table, which is an incremental integer. The maximum value of the node is 2147483647. The agent should wrap the value to 1 and flush all the existing entries when the maximum value is reached.
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2.1.1
hpnicfCfgExecuteResultOptIndexThe configuration execute operation index in the hpnicfCfgExecuteResultTable.ro
Integer32
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2.1.2
hpnicfCfgExecuteResultOpTypeThe operation type in the hpnicfCfgExecuteResultTable.ro
ConfigOperationType
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2.1.3
hpnicfCfgExecuteStateRecord the status of the specified operation.ro
ConfigOperationStateType
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2.1.4
hpnicfCfgExecuteTimeRecord the time of the execution starts.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2.1.5
hpnicfCfgExecuteEndTimeRecord the time of the execution is finished.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.6.2.1.6
hpnicfCfgResetReboot the device with the default configuration.rw
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.7
hpnicfCfgReset2normal:do nothing. reset :reboot the device with the default configuration. 'normal' will be returned when getting. This node differs from hpnicfCfgReset in value.rw
Enumeration
.1.3.6.1.4.1.11.2.14.11.15.2.4.1.2.8
hpnicfConfigManNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.2
hpnicfCfgManEventlogThe object calculates the checksum on the current config per 10 minutes and even if it is different from the saved config but if a trap has been sent with the same checksum then don't send again until the checksum is different.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11.2.14.11.15.2.4.2.1
hpnicfCfgOperateCompletionWhen create hpnicfCfgOperateTable successfully, a notification may be generated.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11.2.14.11.15.2.4.2.2
hpnicfCfgInvalidConfigFileWhen the configuration file is invalid, this notification will be generated.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11.2.14.11.15.2.4.2.3
hpnicfConfigManConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.3
hpnicfConfigManCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.3.1
hpnicfConfigManComplianceThe statement of compliance for those implementing the configuration management MIB.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.4.3.1.1
hpnicfConfigManGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.15.2.4.3.2
hpnicfCfgManLogGroupA collection of objects configuration log group.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.4.3.2.1
hpnicfCfgOperateGroupA group of configuration operation.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.4.3.2.2
hpnicfCfgManNotificationGroupCollection of notification objects.
Unknown
.1.3.6.1.4.1.11.2.14.11.15.2.4.3.2.3