Home/Catalog/HPIPF02TRAP-MIB

HPIPF02TRAP-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for HPIPF02TRAP-MIB.

54
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

54 total
Object Name
hp
OBJECT IDENTIFIER
.1.3.6.1.4.1.11
RFC1213-MIB
Unknown
.1.3.6.1.4.1.11
nm
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2
hpnsa
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.23
hpIpfE0Events
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.23.35
hpIpf02Events
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.23.45
hpTemperature4One of the temperature sensors crossed its upper non-critical threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.4
hpTemperature5One of the temperature sensors crossed its upper critical threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.5
hpTemperature6One of the temperature sensors crossed its upper non-recoverable threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.6
hpEnvironment8One of the voltage sensors crossed its lower critical threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.8
hpEnvironment9One of the voltage sensors crossed its lower non-recoverable threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.9
hpEnvironment10One of the voltage sensors crossed its upper non-critical threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.10
hpEnvironment12One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.12
hpChassis26The chassis has been opened.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.26
hpSystemHW113A SCSI cable has been removed from the hot swap cage.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.113
hpECCMemory518Uncorrectable multi-bit ECC error has occurred in memory module
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.518
hpSystemFW699Machine Check Initiated
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.699
hpSystemFW700System firmware error
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.700
hpEnvironment704Voltage fault - Check all boards with this voltage
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.704
hpEnvironment705Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.705
hpEnvironment706Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.706
hpEnvironment707Voltage absent
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.707
hpFan710Fan speed lags
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.710
hpRedundantPower720Power supply failed or disconnected
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.720
hpRedundantPower722Power supply AC lost
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.722
hpPowerSupply726A/C Failed, disconnected, or out of range
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.726
hpEnvironment728Voltage degraded to critical level from less severe - Check all boards with this voltage
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.728
hpSystemHW729System shut-down or reset caused by sensor reading.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.729
hpBmcFirmware730The BMC firmware did not detect the system firmware boot.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.730
hpPowerSupply731A/C Failed, disconnected, or out of range
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.731
hpRedundantPower732The Power supply's sensors detect possible problems
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.732
hpSystemHW733Cooling unit warning
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.733
hpSystemHW734Cooling unit failure
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.734
hpSystemHW735BMC entering special mode
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.735
hpSystemHW736Watchdog timer expired - hard reset
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.736
hpSystemHW737Watchdog timer expired - power-off
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.737
hpSystemHW738Watchdog timer expired - power-cycle
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.738
hpSystemHW739Missing FRU device
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.739
hpSystemHW740Missing Entity
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.740
hpSystemHW744System event log almost full
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.744
hpSystemHW745TOC interrupt (crash dump)
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.745
hpSystemHW746INIT Initiated
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.746
hpSystemHW747PCI system error detected
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.747
hpSystemHW748OS run-time critical shutdown
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.748
hpSystemHW749ACPI state S5 (soft-off, entered by override)
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.749
hpSystemHW751PCI parity error detected
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.751
hpTempHighWarning752One of the temperature sensors crossed its lower non-critical threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.752
hpTempHighCritical753One of the temperature sensors crossed its upper critical threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.753
hpTempHighNonRecoverable754One of the temperature sensors crossed its upper non-recoverable threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.754
hpTemperature755A temperature inside the server has gone outside the factory specified range.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.755
hpTemperature756One of the temperature sensors crossed its upper critical threshold.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.756
hpRedundantPower757The Power Supply AC voltage was lost or is out of range.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.757
hpRedundantPower758The AC voltage connected to the power supply is out of range.
TRAP-TYPE
.1.3.6.1.4.1.11.2.23.45.0.758
hpIpfEvtDetailStrThis string provides a detailed description of the Event along with variable information.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.23.45.1
HPIPF02TRAP-MIB - SNMP MIB Reference | MIBs Explorer