HP-VSF-VC-MIB
This MIB module describes the objects that are used to manage VSF Virtual Chassis feature.
Main OID:
hpicfVsfVCMIB.1.3.6.1.4.1.25506.11.1.116
76
Objects
Active
Status
10
Dependencies
Imported Objects
Objects
76 total| Object Name |
|---|
hpicfVsfVCMIBThis MIB module describes the objects that are used to
manage VSF Virtual Chassis feature. MODULE-IDENTITY .1.3.6.1.4.1.25506.11.1.116 |
IMPORTSThis MIB module describes the objects that are used to
manage VSF Virtual Chassis feature. Unknown .1.3.6.1.4.1.25506.11.1.116 |
hpicfVsfVCNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.0 |
hpicfVsfVCCommanderChangeThis notification is generated when a new VSF commander
first comes up. The notification is also sent when a
failover happens, and the VSF standby becomes an VSF
commander or when the VSF commander is down. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.11.1.116.0.2 |
hpicfVsfVCMemberChangeThis notification is generated when a new member joins the VSF
virtual chassis or when a member switch is moved from the
loose-provisioned state to the strict-provisioned state. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.11.1.116.0.3 |
hpicfVsfVCMemberStatusChangeThis notification is generated when an VSF member becomes
active or inactive. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.11.1.116.0.4 |
hpicfVsfVCObjects OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.1 |
hpicfVsfVCConfig OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.1.1 |
hpicfVsfVCDomainIdThe VSF virtual chassis domain ID uniquely identifies the VSF
virtual chassis; all members of the virtual chassis have the
same virtual chassis domain ID. The VSF virtual chassis domain
ID is valid only when hpicfVsfVCSwitchAdminStatus is set to
true (1). This value is set by the first elected commander of
the VSF virtual chassis.rw Unsigned32 .1.3.6.1.4.1.25506.11.1.116.1.1.1 |
hpicfVsfVCOperStatusThis is the current operational status of the VSF virtual chassis.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.2 |
hpicfVsfVCAdminStatusThe administrative status of the VSF virtual chassis. When set to
enable (1), this object enables VSF on the switch and on the
discovered members. Setting this to disable (2) disables VSF
only on the standalone switch. Enabling or disabling VSF triggers
a reboot of the VSF switch.rw Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.3 |
hpicfVsfVCTopologyThis object describes the physical topology of the VSF virtual chassis.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.4 |
hpicfVsfVCTrapEnableThis object controls the ability of the VSF virtual chassis to send
traps.rw Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.5 |
hpicfVsfVCOobmMADEnableThis object enables the VSF OOBM MAD (Multi-Active Detection) feature.rw Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.6 |
hpicfVsfLldpMADEnableThis object enables the VSF LLDP MAD (Multi-Active Detection) feature.rw Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.7 |
hpicfVsfVCLldpMADDeviceIpTypeThis object provides the address type of the VSF LLDP MAD
(Multi-Active Detection)device.rw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.25506.11.1.116.1.1.8 |
hpicfVsfVCLldpMADDeviceIpAddrThis object provides the IPv4/IPv6 address of the VSF LLDP MAD
(Multi-Active Detection) device.rw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.25506.11.1.116.1.1.9 |
hpicfVsfVCLldpMADSnmpVersionThis object provides the VSF LLDP MAD (Multi-Active Detection) SNMP
version.rw Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.10 |
hpicfVsfVCLldpMADSnmpCommunityThis object provides the VSF LLDP MAD (Multi-Active Detection)
SNMP community-string.rw OCTET STRING .1.3.6.1.4.1.25506.11.1.116.1.1.11 |
hpicfVsfMADVlanThis object configures the VLAN as a Multi-Active Detection
(MAD) VLAN. The MAD VLAN will be used to send and receive
discovery packets to detect virtual chassis fragments in case
of a split. The default value (0) of the object indicates that
no MAD VLAN is currently configured.rw Integer32 .1.3.6.1.4.1.25506.11.1.116.1.1.12 |
hpicfVsfMADVlanConnectivityThis object indicates the connectivity state of Multi-
Active-Detection (MAD) VLAN.
none (1) - When the MAD VLAN does not have any operational
port in all member switches.
full (2) - When the MAD VLAN has one up port
in all member switches.
partial (3) - When the MAD VLAN has some up ports but does not
have an operational port in all member switches.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.13 |
hpicfVsfVCPortSpeedThis object is used to set the speed of all VSF ports.
If this object is not set, it is automatically set to the
maximum speed of the first link port added to the VSF.
The value none(0) indicates that no VSF links have been
added so the speed is unknown.rw Enumeration .1.3.6.1.4.1.25506.11.1.116.1.1.14 |
hpicfVsfVCStatus OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.1.2 |
hpicfVsfVCLldpMADReadinessStatusThis object indicates the readiness state of VSF LLDP MAD
(Multi-Active Detection).ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.2.1 |
hpicfVsfVCLldpMADDeviceMACThis object indicates the MAC address of the VSF LLDP MAD
(Multi-Active Detection) helper-device.ro OCTET STRING .1.3.6.1.4.1.25506.11.1.116.1.2.2 |
hpicfVsfVCLldpMADVlanIdThis object indicates the VLAN-ID of the domain on which
the VSF LLDP MAD (Multi-Active Detection) helper-device
resides.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.2.3 |
hpicfVsfVCLldpMADTrunkIfIndexThis object indicates the trunk ifIndex of the interface on
the VSF device that is connected to the VSF LLDP MAD
(Multi-Active Detection) helper-device.ro InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.25506.11.1.116.1.2.4 |
hpicfVsfVCLldpMADProbePortSetThis object indicates the list of physical ports on the VSF
LLDP MAD (Multi-Active Detection) helper-device that will be
probed for operational status during MAD probe.ro PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.25506.11.1.116.1.2.5 |
hpicfVsfVCLldpMADConnectivityThis object indicates the reachability state of the VSF LLDP MAD
(Multi-Active Detection) helper-device.
none (1) - When there is no connectivity to the LLDP MAD
helper-device.
full (2) - When the LAG has at least one physical port in
the enabled state on every VSF member switch.
partial (3) - When the LAG does not have at least one enabled
VSF physical port on every VSF member switch.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.2.6 |
hpicfVsfVCLldpMADSplitStatusThis object indicates the VSF LLDP MAD (Multi-Active Detection)
split status.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.2.7 |
hpicfVsfVCLldpMADProbeOriginatorThis object indicates whether the VSF fragment is running
the VSF LLDP MAD (Multi-Active Detection) probe or not.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.2.8 |
hpicfVsfVCLldpMADProbeRequestsSentThis is the number of SNMP queries sent to the VSF LLDP MAD
(Multi-Active Detection) helper-device.ro Counter32 .1.3.6.1.4.1.25506.11.1.116.1.2.9 |
hpicfVsfVCLldpMADProbeResponseRcvdThis is the number of SNMP responses received from the VSF
LLDP MAD (Multi-Active Detection) helper-device.ro Counter32 .1.3.6.1.4.1.25506.11.1.116.1.2.10 |
hpicfVsfVCLldpMADActiveFragmentThis object specifies whether this VSF fragment is the active
or an inactive fragment.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.2.11 |
hpicfVsfVCMemberTableThis table contains information about the VSF virtual
chassis members. SEQUENCE OF HpicfVsfVCMemberEntry .1.3.6.1.4.1.25506.11.1.116.1.3 |
hpicfVsfVCMemberEntryA row in the VSF virtual chassis member table. HpicfVsfVCMemberEntry .1.3.6.1.4.1.25506.11.1.116.1.3.1 |
hpicfVsfVCMemberIdThis object describes the VSF virtual chassis member ID. Integer32 .1.3.6.1.4.1.25506.11.1.116.1.3.1.1 |
hpicfVsfVCMemberProductIdThis object describes the type of VSF member-switch.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.3.1.2 |
hpicfVsfVCMemberMacAddrThis object specifies the VSF member-switch MAC address.rw OCTET STRING .1.3.6.1.4.1.25506.11.1.116.1.3.1.3 |
hpicfVsfVCMemberShutdownWhen this object is set to true (1) for a specific active-member
VSF virtual chassis switch, that switch will shut down. Setting
the object to false (2) has no effect. This object cannot be set
to true (1) if the specified member is an VSF commander. If the
VSF member is in standby mode, a new standby switch is chosen.
The VSF member shutdown is prevented if it will cause a virtual
chassis split.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.3.1.4 |
hpicfVsfVCMemberRebootWhen set to true (1), this object will reboot the VSF member-switch.
Setting the object to false (2) has no effect. Reboot is prevented if
it will cause a virtual chassis split.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.3.1.5 |
hpicfVsfVCMemberAdminPriorityThis object allows the user to set the priority of a switch when VSF
is enabled on it.rw Integer32 .1.3.6.1.4.1.25506.11.1.116.1.3.1.6 |
hpicfVsfVCMemberEntryStatusThis object indicates the row status of an VSF virtual chassis-member
entry. If the VSF member ID corresponds to an VSF commander, the row
cannot be destroyed.
For active switches, if hpicfVsfVCMemberReboot is set to true (1), and
the row status is set to destroy (6), the switch comes up with a default
configuration and acquires a new hpicfVsfVCMemberId.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.3.1.7 |
hpicfVsfVCMemberEntPhysicalIndexThis object specifies the entPhysicalTable (rfc2737) index of the
VSF member.ro PhysicalIndex (ENTITY-MIB) .1.3.6.1.4.1.25506.11.1.116.1.3.1.8 |
hpicfVsfVCMemberStateThis object gives the status of the member-switch in the VSF
virtual chassis.
unusedId (0) - The member ID does not exist.
missing (1) - An VSF virtual chassis member-switch is marked as
missing when it becomes non-responsive. A lack of
response from the switch means that either the
virtual chassis link or the virtual chassis member
has crashed. Note that it is possible to remove a
missing member from the virtual chassis. Once removed,
the missing member's configuration will be deleted
from the virtual chassis configuration file.
provision (2) - A member-switch that is not physically present
but whose configuration is provisioned .
commander (3) - The member-switch which is the commander of the
VSF virtual chassis.
standby (4) - The member-switch which is the standby of the
VSF virtual chassis.
member (5) - The member-switch that is a part of the VSF
virtual chassis.
shutdown (6) - The member-switch is in the shut down state.
booting (7) - The member-switch is booting.
communicationFailure (8)- The member-switch cannot be reached.
incompatibleOS (9) - The member-switch is running with a different
Operating System.
unknownState (10) - The state of the member-switch cannot be determined.
standbyBooting (11)- The standby switch is currently booting up. When
the switch finishes booting, its state will change
to standby (4).ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.3.1.9 |
hpicfVsfVCMemberProductNameThe product name of the VSF member-switch.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.25506.11.1.116.1.3.1.10 |
hpicfVsfVCMemberUpTimeThis object provides the uptime of the VSF member-switch. This
is different from the VSF chassis uptime.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.25506.11.1.116.1.3.1.11 |
hpicfVsfVCMemberSysOidThis object provides the sysObjectId of the VSF member-switch.ro OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.1.3.1.12 |
hpicfVsfVCMemberIdForTrapThe member ID used in trap notifications. This is the same value
as hpicfVsfVCMemberId.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.3.1.13 |
hpicfVsfVCMemberSerialNumThis object specifies the serial number of the VSF member-switch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.3.1.14 |
hpicfVsfVCMemberBootRomVersionThis object specifies the boot-ROM version of the VSF member-switch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.3.1.15 |
hpicfVsfVCMemberOsVersionThis object specifies the operating system version of the VSF member-switch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.3.1.16 |
hpicfVsfVCMemberBootImageThis object specifies the boot image of the VSF member-switch.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.3.1.17 |
hpicfVsfVCMemberRenumberThis object specifies the new member ID to be assigned to this
VSF virtual chassis member-switch.rw Integer32 .1.3.6.1.4.1.25506.11.1.116.1.3.1.18 |
hpicfVsfVCMemberCpuUtilThis object provides the percentage of CPU utilization of the
VSF member-switch.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.3.1.19 |
hpicfVsfVCMemberTotalMemoryThis object provides the total memory usage in bytes of the
VSF member-switch.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.3.1.20 |
hpicfVsfVCMemberFreeMemoryThis object provides the free memory available, in bytes, on
the VSF member-switch.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.3.1.21 |
hpicfVsfVCLinkTableThis table contains information about the VSF links. An VSF link is
a logical interface for the connection between VSF member devices.
To use an VSF link, you must bind at least one physical port to it.
These ports are called 'VSF physical ports' or 'VSF Ports'. The
physical ports assigned to an VSF link automatically form an aggregate
VSF link. An VSF link goes down only if all of its members' physical
ports are down. SEQUENCE OF HpicfVsfVCLinkEntry .1.3.6.1.4.1.25506.11.1.116.1.4 |
hpicfVsfVCLinkEntryA row in the VSF link table. HpicfVsfVCLinkEntry .1.3.6.1.4.1.25506.11.1.116.1.4.1 |
hpicfVsfVCLinkMemberIdThis object is the member ID of the VSF virtual chassis to which
this VSF link belongs. Integer32 .1.3.6.1.4.1.25506.11.1.116.1.4.1.1 |
hpicfVsfVCLinkIdThis object indicates the link ID for this VSF entry. Integer32 .1.3.6.1.4.1.25506.11.1.116.1.4.1.2 |
hpicfVsfVCLinkNameThis object indicates the VSF link name. The maximum allowed
link name is 32 characters.rw DisplayString .1.3.6.1.4.1.25506.11.1.116.1.4.1.3 |
hpicfVsfVCLinkOperStatusThis object indicates the VSF link state.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.4.1.4 |
hpicfVsfVCPeerMemberIdThis object indicates the peer-member ID to which the VSF link is
connected.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.4.1.5 |
hpicfVsfVCPeerLinkIdThis object indicates the VSF link ID of the peer-member to which
this VSF link is connected.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.4.1.6 |
hpicfVsfVCLinkPortListThis object indicates the list of physical ports belonging to
this VSF link.rw PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.25506.11.1.116.1.4.1.7 |
hpicfVsfVCLinkEntryStatusThis object indicates the row status of an VSF virtual chassis
link entry.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.4.1.8 |
hpicfVsfVCLinkIdForTrapThis object indicates the VSF virtual chassis link ID used in
trap notifications. This is the same value as hpicfVsfVCLinkId.ro Integer32 .1.3.6.1.4.1.25506.11.1.116.1.4.1.9 |
hpicfVsfVCLinkPortStartStateThis object indicates whether ports should be enabled while
creating the VSF virtual chassis link.rw Enumeration .1.3.6.1.4.1.25506.11.1.116.1.4.1.10 |
hpicfVsfVCPortTableThis table contains information about the VSF
virtual chassis physical ports. SEQUENCE OF HpicfVsfVCPortEntry .1.3.6.1.4.1.25506.11.1.116.1.5 |
hpicfVsfVCPortEntryA row in the VSF port table. HpicfVsfVCPortEntry .1.3.6.1.4.1.25506.11.1.116.1.5.1 |
hpicfVsfVCPortOperStatusThis object provides the VSF virtual chassis physical
port state.ro Enumeration .1.3.6.1.4.1.25506.11.1.116.1.5.1.1 |
hpicfVsfVCPortOperStatusErrorStrThis object provides an error message if hpicfVsfVCPortOperStatus
returns the value error (3).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.116.1.5.1.2 |
hpicfVsfVCConformance OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.2 |
hpicfVsfVCCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.2.1 |
hpicfVsfVCGroups OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.116.2.2 |