Home/Catalog/HP-ICF-TRANSCEIVER-MIB

HP-ICF-TRANSCEIVER-MIB

AI MIB Summary

The HP-ICF-TRANSCEIVER-MIB enables monitoring of optical transceiver parameters on HP networking hardware, specifically tracking operational status, optical power levels, temperature, and voltage metrics for installed SFP modules.

This MIB module describes HP transceiver information.
Main OID:
hpicfTransceiverMIB.1.3.6.1.4.1.11.2.14.11.5.1.82
76
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

76 total
Object Name
hpicfTransceiverMIBThis MIB module describes HP transceiver information.
MODULE-IDENTITY
.1.3.6.1.4.1.11.2.14.11.5.1.82
hpicfXcvrObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.5.1.82.1
hpicfXcvrInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1
hpicfXcvrInfoTableA table of objects that display transceiver characteristics.
SEQUENCE OF HpicfXcvrInfoEntry
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1
hpicfXcvrInfoEntryA set of objects that displays information of a transceiver.
HpicfXcvrInfoEntry
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1
hpicfXcvrPortIndexThe interface number for this entry.ro
Integer32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.1
hpicfXcvrPortDescA textual description of the interface.ro
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.2
hpicfXcvrModelA textual description of the transceiver model number.ro
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.3
hpicfXcvrSerialA textual description of the transceiver serial number.ro
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.4
hpicfXcvrTypeA textual description of the transceiver type.ro
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.5
hpicfXcvrConnectorTypeA textual description of the transceiver connector type.ro
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.6
hpicfXcvrWavelengthA textual description of the central optical wavelength. n/a will be reported for copper transceivers.ro
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.7
hpicfXcvrTxDistA textual description of the link length supported by the transceiver.ro
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.8
hpicfXcvrDiagnosticsThis object indicates transceiver diagnostic support. May be one of Virtual Cable Test (VCT), Diagnostic Optical Monitoring (DOM), other or none.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.9
hpicfXcvrDiagnosticsUpdateThis object will cause specific actions depending on the diagnostic support of the transceiver. Transceiver Diagnostic support: None : No action taken. DOM : Will update diagnostic information for the transceiver. VCT : Will update diagnostic information for the transceiver. Other : Vendor specific. The value of the object will be reset after the completion of the update. Please note: VCT and other (cable-diagnostics) may cause a loss of link and take a few second to run for each interface.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.10
hpicfXcvrTempThis is transceiver internal temperature in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Integer32 UNITS "thousandths of degrees Celsius"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11
hpicfXcvrVoltageThis is transceiver supply voltage in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Will be zero if the transceiver does not report this object. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12
hpicfXcvrBiasThis is Tx bias current in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13
hpicfXcvrTxPowerThis is transmit output power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Integer32 UNITS "thousandths of dBm"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14
hpicfXcvrRxPowerThis is received optical power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Integer32 UNITS "thousandths of dBm"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15
hpicfXcvrAlarmsBitmask indicating transceiver alarms, Rx power low warning(0) Rx power high warning(1) Tx power low warning(2) Tx power high warning(3) Tx bias low warning(4) Tx bias high warning(5) Vcc low warning(6) Vcc high warning(7) Temp low warning(8) Temp high warning(9) Rx power low alarm(10) Rx power high alarm(11) Tx power low alarm(12) Tx power high alarm(13) Tx bias low alarm(14) Tx bias high alarm(15) Vcc low alarm(16) Vcc high alarm(17) Temp low alarm(18) Temp high alarm(19) Unused(20-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Bits
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.16
hpicfXcvrErrorsBitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) Unused(17-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Bits
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.17
hpicfXcvrTempHiAlarmTransceiver temperature high alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Integer32 UNITS "thousandths of degrees Celsius"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.18
hpicfXcvrTempLoAlarmTransceiver temperature low alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Integer32 UNITS "thousandths of degrees Celsius"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.19
hpicfXcvrTempHiWarnTransceiver temperature high warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Integer32 UNITS "thousandths of degrees Celsius"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.20
hpicfXcvrTempLoWarnTransceiver temperature low warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Integer32 UNITS "thousandths of degrees Celsius"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.21
hpicfXcvrVccHiAlarmTransceiver VCC high alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.22
hpicfXcvrVccLoAlarmTransceiver VCC low alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.23
hpicfXcvrVccHiWarnTransceiver VCC high warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.24
hpicfXcvrVccLoWarnTransceiver VCC low warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.25
hpicfXcvrBiasHiAlarmTransceiver bias high alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.26
hpicfXcvrBiasLoAlarmTransceiver bias low alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.27
hpicfXcvrBiasHiWarnTransceiver bias high warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.28
hpicfXcvrBiasLoWarnTransceiver bias low warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.29
hpicfXcvrPwrOutHiAlarmTransceiver transmit power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.30
hpicfXcvrPwrOutLoAlarmTransceiver transmit power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.31
hpicfXcvrPwrOutHiWarnTransceiver transmit power high warning threshold limit in tenths of microwatts As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.32
hpicfXcvrPwrOutLoWarnTransceiver transmit power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.33
hpicfXcvrRcvPwrHiAlarmTransceiver receive power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.34
hpicfXcvrRcvPwrLoAlarmTransceiver receive power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.35
hpicfXcvrRcvPwrHiWarnTransceiver receive power high warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.36
hpicfXcvrRcvPwrLoWarnTransceiver receive power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.37
hpicfXcvrDiagnosticsTimeStamp********* THIS OBJECT IS DEPRECATED ********* A textual description of the diagnostics information updated for the last time in the transceiver. This object has been deprecated. Its functionality has been replaced by hpicfXcvrDiagnosticsTimeticks.rodeprecated
SnmpAdminString
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.38
hpicfXcvrPhyLinkStatusThis object indicates the link status as reported by the physical entity. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.39
hpicfXcvrPhySpeedThis object indicates the speed in Mbps as reported by the physical entity. Will be zero if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.40
hpicfXcvrPhyDuplexThis object indicates the duplex as reported by the physical entity. Will be unspecified if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.41
hpicfXcvrMdiPairACableStatusThis object indicates the diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.42
hpicfXcvrMdiPairACableLengthThis object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.43
hpicfXcvrMdiPairADistanceToFaultThis object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.44
hpicfXcvrMdiPairAPolaritySwapThis object indicates if the cable pair connected to the phy is inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.45
hpicfXcvrMdiPairASkewThis object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.46
hpicfXcvrMdiPairBCableStatusThis object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.47
hpicfXcvrMdiPairBCableLengthThis object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.48
hpicfXcvrMdiPairBDistanceToFaultThis object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.49
hpicfXcvrMdiPairBPolaritySwapThis object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.50
hpicfXcvrMdiPairBSkewThis object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.51
hpicfXcvrMdiPairCCableStatusThis object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.52
hpicfXcvrMdiPairCCableLengthThis object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.53
hpicfXcvrMdiPairCDistanceToFaultThis object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if there is no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.54
hpicfXcvrMdiPairCPolaritySwapThis object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.55
hpicfXcvrMdiPairCSkewThis object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.56
hpicfXcvrMdiPairDCableStatusThis object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.57
hpicfXcvrMdiPairDCableLengthThis object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.58
hpicfXcvrMdiPairDDistanceToFaultThis object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.59
hpicfXcvrMdiPairDPolaritySwapThis object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.60
hpicfXcvrMdiPairDSkewThis object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Unsigned32
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.61
hpicfXcvrMdiPairABSwapThis object indicates the if the channels are swapped for channels A and B as reported through cable diagnostics. MDI : Channel A received on MDI[1], Channel B on MDI[0] MDIX : Channel A received on MDI[0], Channel B on MDI[1] Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.62
hpicfXcvrMdiPairCDSwapThis object indicates if the channels are swapped for channels C and D as reported through cable diagnostics. MDI : Channel C received on MDI[3], Channel D on MDI[2] MDIX : Channel C received on MDI[2], Channel D on MDI[3]. Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.ro
Enumeration
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.63
hpicfXcvrDiagnosticsTimeTicksThe value of sysUpTime of when this diagnostic information was last updated. If this diagnostic information was never updated, then this object will contain a zero value.ro
TimeTicks UNITS "centi-seconds"
.1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.64
hpicfXcvrConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.5.1.82.2
hpicfXcvrGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.5.1.82.2.1
hpicfXcvrInfoGroup********* THIS GROUP IS DEPRECATED ********* A collection of objects representing transceiver information. This object has been deprecated and replaced with hpicfXcvrInfoGroup1.deprecated
Unknown
.1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.1
hpicfXcvrInfoGroup1A collection of objects representing transceiver information.
Unknown
.1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.2
hpicfXcvrCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.14.11.5.1.82.2.2
hpicfXcvrCompliance********* THIS COMPLIANCE IS DEPRECATED ********* Describes the requirements for conformance to the transceiver MIB. This compliance section has been deprecated and replaced with hpicfXcvrCompliance1.deprecated
Unknown
.1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.1
hpicfXcvrCompliance1Describes the requirements for conformance to the transceiver MIB.
Unknown
.1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.2
HP-ICF-TRANSCEIVER-MIB - SNMP MIB Reference | MIBs Explorer