HH3C-TRANSCEIVER-INFO-MIB
The HH3C-TRANSCEIVER-INFO-MIB module enables monitoring of optical transceiver parameters, including SFP module status, optical power levels, temperature, and voltage, on H3C network interface cards. This data facilitates the detection of hardware degradation and link failures by exposing physical layer telemetry directly from the device's management information base.
Imported Objects
Objects
51 total| Object Name |
|---|
hh3cTransceiver MODULE-IDENTITY .1.3.6.1.4.1.25506.2.70 |
hh3cTransceiverInfoAdm OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.70.1 |
hh3cTransceiverInfoTable SEQUENCE OF Hh3cTransceiverInfoEntry .1.3.6.1.4.1.25506.2.70.1.1 |
hh3cTransceiverInfoEntry Hh3cTransceiverInfoEntry .1.3.6.1.4.1.25506.2.70.1.1.1 |
hh3cTransceiverHardwareTypero OCTET STRING .1.3.6.1.4.1.25506.2.70.1.1.1.1 |
hh3cTransceiverTypero OCTET STRING .1.3.6.1.4.1.25506.2.70.1.1.1.2 |
hh3cTransceiverWaveLengthro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.3 |
hh3cTransceiverVendorNamero OCTET STRING .1.3.6.1.4.1.25506.2.70.1.1.1.4 |
hh3cTransceiverSerialNumberro OCTET STRING .1.3.6.1.4.1.25506.2.70.1.1.1.5 |
hh3cTransceiverFiberDiameterTypero Enumeration .1.3.6.1.4.1.25506.2.70.1.1.1.6 |
hh3cTransceiverTransferDistancero Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.7 |
hh3cTransceiverDiagnosticro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.25506.2.70.1.1.1.8 |
hh3cTransceiverCurTXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.9 |
hh3cTransceiverMaxTXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.10 |
hh3cTransceiverMinTXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.11 |
hh3cTransceiverCurRXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.12 |
hh3cTransceiverMaxRXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.13 |
hh3cTransceiverMinRXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.14 |
hh3cTransceiverTemperaturero Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.15 |
hh3cTransceiverVoltagero Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.16 |
hh3cTransceiverBiasCurrentro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.17 |
hh3cTransceiverTempHiAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.18 |
hh3cTransceiverTempLoAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.19 |
hh3cTransceiverTempHiWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.20 |
hh3cTransceiverTempLoWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.21 |
hh3cTransceiverVccHiAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.22 |
hh3cTransceiverVccLoAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.23 |
hh3cTransceiverVccHiWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.24 |
hh3cTransceiverVccLoWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.25 |
hh3cTransceiverBiasHiAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.26 |
hh3cTransceiverBiasLoAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.27 |
hh3cTransceiverBiasHiWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.28 |
hh3cTransceiverBiasLoWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.29 |
hh3cTransceiverPwrOutHiAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.30 |
hh3cTransceiverPwrOutLoAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.31 |
hh3cTransceiverPwrOutHiWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.32 |
hh3cTransceiverPwrOutLoWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.33 |
hh3cTransceiverRcvPwrHiAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.34 |
hh3cTransceiverRcvPwrLoAlarmro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.35 |
hh3cTransceiverRcvPwrHiWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.36 |
hh3cTransceiverRcvPwrLoWarnro Integer32 .1.3.6.1.4.1.25506.2.70.1.1.1.37 |
hh3cTransceiverErrorsro Bits .1.3.6.1.4.1.25506.2.70.1.1.1.38 |
hh3cTransceiverVendorOUIro OCTET STRING .1.3.6.1.4.1.25506.2.70.1.1.1.39 |
hh3cTransceiverRevisionNumberro OCTET STRING .1.3.6.1.4.1.25506.2.70.1.1.1.40 |
hh3cTransceiverChannelTable SEQUENCE OF Hh3cTransceiverChannelEntry .1.3.6.1.4.1.25506.2.70.1.2 |
hh3cTransceiverChannelEntry Hh3cTransceiverChannelEntry .1.3.6.1.4.1.25506.2.70.1.2.1 |
hh3cTransceiverChannelIndex Integer32 .1.3.6.1.4.1.25506.2.70.1.2.1.1 |
hh3cTransceiverChannelCurTXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.2.1.2 |
hh3cTransceiverChannelCurRXPowerro Integer32 .1.3.6.1.4.1.25506.2.70.1.2.1.3 |
hh3cTransceiverChannelTemperaturero Integer32 .1.3.6.1.4.1.25506.2.70.1.2.1.4 |
hh3cTransceiverChannelBiasCurrentro Integer32 .1.3.6.1.4.1.25506.2.70.1.2.1.5 |
HH3C-TRANSCEIVER-INFO-MIB Technical Reference Overview
The HH3C-TRANSCEIVER-INFO-MIB SNMP MIB module published by Hangzhou H3C defines 51 managed OID objects, including 45 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.25506.2.70. Key tabular structures include hh3cTransceiverChannelTable, hh3cTransceiverInfoTable.
Key OID Definitions in HH3C-TRANSCEIVER-INFO-MIB
.1.3.6.1.4.1.25506.2.70The objects in this MIB module are used to display the information of transceiver on interface.
.1.3.6.1.4.1.25506.2.70.1.2This table provides statistics about transceiver with multi-channel.
.1.3.6.1.4.1.25506.2.70.1.1This table shows transceiver information on an interface.
.1.3.6.1.4.1.25506.2.70.1.1.1.17Indicating the current bias electric current. The unit is in hundredths of mA
.1.3.6.1.4.1.25506.2.70.1.1.1.26Transceiver bias high alarm threshold limit in microamps.
.1.3.6.1.4.1.25506.2.70.1.1.1.28Transceiver bias high warning threshold limit in microamps.
.1.3.6.1.4.1.25506.2.70.1.1.1.27Transceiver bias low alarm threshold limit in microamps.
.1.3.6.1.4.1.25506.2.70.1.1.1.29Transceiver bias low warning threshold limit in microamps.
.1.3.6.1.4.1.25506.2.70.1.2.1.5Indicating the current bias electric current. The unit is in hundredths of mA.
.1.3.6.1.4.1.25506.2.70.1.2.1.3Indicating the current received power. The unit is in hundredths of dBM.
.1.3.6.1.4.1.25506.2.70.1.2.1.2Indicating the current transmission power. The unit is in hundredths of dBM.
.1.3.6.1.4.1.25506.2.70.1.2.1The entry of the hh3cTransceiverChannelTable.
.1.3.6.1.4.1.25506.2.70.1.2.1.1The channel index of transceiver. Indicating one channel of the interface.
.1.3.6.1.4.1.25506.2.70.1.2.1.4Indicating the current temperature. The unit is Celsius centigrade.
.1.3.6.1.4.1.25506.2.70.1.1.1.12Indicating the current received power. The unit is in hundredths of dBM.
.1.3.6.1.4.1.25506.2.70.1.1.1.9Indicating the current transmitted power. The unit is in hundredths of dBM.
.1.3.6.1.4.1.25506.2.70.1.1.1.8Indicating the digital diagnostic monitoring function.
.1.3.6.1.4.1.25506.2.70.1.1.1.38Bitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) Unused(17-31)
.1.3.6.1.4.1.25506.2.70.1.1.1.6The diameter of the fiber, measured in micron. fiber9 - 9 micron multi-mode fiber fiber50 - 50 micron multi-mode fiber fiber625 - 62.5 micron multi-mode fiber copper - copper cable.
.1.3.6.1.4.1.25506.2.70.1.1.1.1Hardware type of the interface, such as SM(single mode).
.1.3.6.1.4.1.25506.2.70.1.1.1The entry of the hh3cTransceiverInfoTable.
.1.3.6.1.4.1.25506.2.70.1.1.1.13Indicating the maximum received power. The unit is in hundredths of dBM.
.1.3.6.1.4.1.25506.2.70.1.1.1.10Indicating the maximum transmitted power. The unit is in hundredths of dBM.
.1.3.6.1.4.1.25506.2.70.1.1.1.14Indicating the minimum received power. The unit is in hundredths of dBM.
More MIBs from Hangzhou H3C
Browse all Hangzhou H3CMIBs →The HH3C-DOT11-APMT-MIB module enables monitoring of H3C wireless access points (both Fat and Fit modes) and their associated Access Controllers via CAPWAP tunnels, specifically tracking real-time AP operational states, association statistics, and BSS radio metrics.
The HH3C-ACL-MIB enables monitoring and configuration of Access Control List (ACL) entries, packet filtering rules, and associated hit counters on H3C network devices. It provides visibility into specific traffic matching statistics, rule hit counts, and policy enforcement status for ingress and egress filtering operations.
The HH3C-CBQOS2-MIB enables the configuration and real-time monitoring of Class-Based QoS policies on H3C network devices, specifically tracking classifier definitions, traffic matching rules, behavior actions (such as CAR, GTS, and WRED), and policy application status across interfaces, VLANs, and PVCs.
SNMP MIB module
SNMP MIB module
SNMP MIB module