HH3C-SECHIGH-MIB
The HH3C-SECHIGH-MIB provides vendor-specific SNMP management capabilities for H3C high-end security appliances, enabling the monitoring of driver-level operational states and performance metrics specific to their high-performance security hardware.
Imported Objects
Objects
49 total| Object Name |
|---|
hh3cSecHigh MODULE-IDENTITY .1.3.6.1.4.1.25506.2.171 |
hh3cSecHighMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1 |
hh3cSecHighHgMonitorAlarmVar OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1.1 |
hh3cSecHighHgMonitorAlarmTypero Integer32 .1.3.6.1.4.1.25506.2.171.1.1.1 |
hh3cSecHighHgMonitorAlarmSrcChassisro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.2 |
hh3cSecHighHgMonitorAlarmSrcSlotro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.3 |
hh3cSecHighHgMonitorAlarmSrcChipro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.4 |
hh3cSecHighHgMonitorAlarmSrcPortro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.5 |
hh3cSecHighHgMonitorAlarmDstChassisro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.6 |
hh3cSecHighHgMonitorAlarmDstSlotro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.7 |
hh3cSecHighHgMonitorAlarmDstChipro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.8 |
hh3cSecHighHgMonitorAlarmDstPortro Integer32 .1.3.6.1.4.1.25506.2.171.1.1.9 |
hh3cSecHighHgMonitorAlarmReasonro OCTET STRING .1.3.6.1.4.1.25506.2.171.1.1.10 |
hh3cSecHighHgMonitorAlarmTrap OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1.2 |
hh3cSecHighHgMonitorAlarmNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1.2.0 |
hh3cSecHighHgMonitorAlarmNotification NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.171.1.2.0.1 |
hh3cSecHighFaultMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1.3 |
hh3cSecHighFaultAlmVar OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1.3.1 |
hh3cSecHighFaultAlmTypero Integer32 .1.3.6.1.4.1.25506.2.171.1.3.1.1 |
hh3cSecHighFaultAlmChassisro Integer32 .1.3.6.1.4.1.25506.2.171.1.3.1.2 |
hh3cSecHighFaultAlmSlotro Integer32 .1.3.6.1.4.1.25506.2.171.1.3.1.3 |
hh3cSecHighFaultAlmDstChassisro Integer32 .1.3.6.1.4.1.25506.2.171.1.3.1.4 |
hh3cSecHighFaultAlmDstSlotro Integer32 .1.3.6.1.4.1.25506.2.171.1.3.1.5 |
hh3cSecHighFaultAlmChipro Integer32 .1.3.6.1.4.1.25506.2.171.1.3.1.6 |
hh3cSecHighFaultAlmInforo OCTET STRING .1.3.6.1.4.1.25506.2.171.1.3.1.7 |
hh3cSecHighFaultAlmTrap OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1.3.2 |
hh3cSecHighFaultAlmTrapPre OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.1.3.2.0 |
hh3cSecHighFaultMonChipAlmNotifi NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.171.1.3.2.0.1 |
hh3cSecHighFaultMonChipAlmResu NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.171.1.3.2.0.2 |
hh3cSecHighFaultMonHgAlmNotifi NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.171.1.3.2.0.3 |
hh3cSecHighFaultMonHgAlmResu NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.171.1.3.2.0.4 |
hh3cSecHighTemperMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.2 |
hh3cSecHighTemperAlarmVar OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.2.1 |
hh3cSecHighTemperAlarmChassisro Integer32 .1.3.6.1.4.1.25506.2.171.2.1.1 |
hh3cSecHighTemperAlarmSlotro Integer32 .1.3.6.1.4.1.25506.2.171.2.1.2 |
hh3cSecHighTemperAlarmHotspotIndxro Integer32 .1.3.6.1.4.1.25506.2.171.2.1.3 |
hh3cSecHighTemperAlarmCurTemperro Integer32 .1.3.6.1.4.1.25506.2.171.2.1.4 |
hh3cSecHighTemperAlarmLimitro Integer32 .1.3.6.1.4.1.25506.2.171.2.1.5 |
hh3cSecHighTemperAlarmTrap OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.2.2 |
hh3cSecHighTemperAlmTrapPre OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.2.2.0 |
hh3cSecHighTemperAlarmNotify NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.171.2.2.0.1 |
hh3cSecHighParityErrorMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.3 |
hh3cSecHighParityErrorAlarmVar OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.3.1 |
hh3cSecHighParityErrorAlarmChassisro Integer32 .1.3.6.1.4.1.25506.2.171.3.1.1 |
hh3cSecHighParityErrorAlarmSlotro Integer32 .1.3.6.1.4.1.25506.2.171.3.1.2 |
hh3cSecHighParityErrorAlarmChipUnitro Integer32 .1.3.6.1.4.1.25506.2.171.3.1.3 |
hh3cSecHighParityErrorAlarmTrap OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.3.2 |
hh3cSecHighParityErrorAlarmTrapPre OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.171.3.2.0 |
hh3cSecHighParityErrorAlarmNotify NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.171.3.2.0.1 |
HH3C-SECHIGH-MIB Technical Reference Overview
The HH3C-SECHIGH-MIB SNMP MIB module published by Hangzhou H3C defines 49 managed OID objects, including 25 scalar/column metrics, 0 SNMP tables, and 7 trap/notification events anchored at base OID .1.3.6.1.4.1.25506.2.171. Monitored SNMP traps/notifications include hh3cSecHighFaultMonChipAlmNotifi, hh3cSecHighFaultMonChipAlmResu, hh3cSecHighFaultMonHgAlmNotifi, hh3cSecHighFaultMonHgAlmResu, hh3cSecHighHgMonitorAlarmNotification, hh3cSecHighParityErrorAlarmNotify.
Key OID Definitions in HH3C-SECHIGH-MIB
.1.3.6.1.4.1.25506.2.171The private MIB file includes the information on high-end driver products.
.1.3.6.1.4.1.25506.2.171.1.3.2.0.1This notification is generated when a chip error occurs.
.1.3.6.1.4.1.25506.2.171.1.3.2.0.2This notification is generated when a chip error is recovered.
.1.3.6.1.4.1.25506.2.171.1.3.2.0.3This notification is generated when an Hg error occurs.
.1.3.6.1.4.1.25506.2.171.1.3.2.0.4This notification is generated when an Hg error is recovered.
.1.3.6.1.4.1.25506.2.171.1.2.0.1This notification is generated when an HgMonitor alarm is generated.
.1.3.6.1.4.1.25506.2.171.3.2.0.1This notification is generated when a severe parity error occurs.
.1.3.6.1.4.1.25506.2.171.2.2.0.1This notification is generated when a hotspot's temperature exceeds its power down threshold.
.1.3.6.1.4.1.25506.2.171.1.3.1.2Number of the chassis in which error occurs.
.1.3.6.1.4.1.25506.2.171.1.3.1.6Id of the error chip.
.1.3.6.1.4.1.25506.2.171.1.3.1.4Number of the destination chassis in which Hg error occurs.
.1.3.6.1.4.1.25506.2.171.1.3.1.5Number of the destination slot in which Hg error occurs.
.1.3.6.1.4.1.25506.2.171.1.3.1.7Details of the alarm notification.
.1.3.6.1.4.1.25506.2.171.1.3.1.3Number of the slot in which error occurs.
.1.3.6.1.4.1.25506.2.171.1.3.1.1Type of the alarm, 1 represents Hg link status error, 2 represents Hg packet loss error, 3 represents back board E2PROM error, 4 represents board E2PROM error, 5 represents CPLD chip error, 101 to 200 represent FPGA errors.
.1.3.6.1.4.1.25506.2.171.1.1.6Number of the chassis where the destination end of the alarmed link resides.
.1.3.6.1.4.1.25506.2.171.1.1.8Number of the chip where the destination end of the alarmed link resides.
.1.3.6.1.4.1.25506.2.171.1.1.9Number of the port where the destination end of the alarmed link resides.
.1.3.6.1.4.1.25506.2.171.1.1.7Number of the slot where the destination end of the alarmed link resides.
.1.3.6.1.4.1.25506.2.171.1.1.10Cause of the alarm.
.1.3.6.1.4.1.25506.2.171.1.1.2Number of the chassis where the source end of the alarmed link resides.
.1.3.6.1.4.1.25506.2.171.1.1.4Number of the chip where the source end of the alarmed link resides.
.1.3.6.1.4.1.25506.2.171.1.1.5Number of the port where the source end of the alarmed link resides.
.1.3.6.1.4.1.25506.2.171.1.1.3Number of the slot where the source end of the alarmed link resides.
More MIBs from Hangzhou H3C
Browse all Hangzhou H3CMIBs →The HH3C-DOT11-APMT-MIB module enables monitoring of H3C wireless access points (both Fat and Fit modes) and their associated Access Controllers via CAPWAP tunnels, specifically tracking real-time AP operational states, association statistics, and BSS radio metrics.
The HH3C-ACL-MIB enables monitoring and configuration of Access Control List (ACL) entries, packet filtering rules, and associated hit counters on H3C network devices. It provides visibility into specific traffic matching statistics, rule hit counts, and policy enforcement status for ingress and egress filtering operations.
The HH3C-CBQOS2-MIB enables the configuration and real-time monitoring of Class-Based QoS policies on H3C network devices, specifically tracking classifier definitions, traffic matching rules, behavior actions (such as CAR, GTS, and WRED), and policy application status across interfaces, VLANs, and PVCs.
SNMP MIB module
SNMP MIB module
SNMP MIB module