Home/Catalog/HH3C-SECHIGH-MIB

HH3C-SECHIGH-MIB

AI MIB Summary

The HH3C-SECHIGH-MIB provides vendor-specific SNMP management capabilities for H3C high-end security appliances, enabling the monitoring of driver-level operational states and performance metrics specific to their high-performance security hardware.

The private MIB file includes the information on high-end driver products.
Main OID:
hh3cSecHigh.1.3.6.1.4.1.25506.2.171
49
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

49 total
Object Name
hh3cSecHigh
MODULE-IDENTITY
.1.3.6.1.4.1.25506.2.171
hh3cSecHighMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1
hh3cSecHighHgMonitorAlarmVar
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1.1
hh3cSecHighHgMonitorAlarmTypero
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.1
hh3cSecHighHgMonitorAlarmSrcChassisro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.2
hh3cSecHighHgMonitorAlarmSrcSlotro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.3
hh3cSecHighHgMonitorAlarmSrcChipro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.4
hh3cSecHighHgMonitorAlarmSrcPortro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.5
hh3cSecHighHgMonitorAlarmDstChassisro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.6
hh3cSecHighHgMonitorAlarmDstSlotro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.7
hh3cSecHighHgMonitorAlarmDstChipro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.8
hh3cSecHighHgMonitorAlarmDstPortro
Integer32
.1.3.6.1.4.1.25506.2.171.1.1.9
hh3cSecHighHgMonitorAlarmReasonro
OCTET STRING
.1.3.6.1.4.1.25506.2.171.1.1.10
hh3cSecHighHgMonitorAlarmTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1.2
hh3cSecHighHgMonitorAlarmNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1.2.0
hh3cSecHighHgMonitorAlarmNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.171.1.2.0.1
hh3cSecHighFaultMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1.3
hh3cSecHighFaultAlmVar
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1.3.1
hh3cSecHighFaultAlmTypero
Integer32
.1.3.6.1.4.1.25506.2.171.1.3.1.1
hh3cSecHighFaultAlmChassisro
Integer32
.1.3.6.1.4.1.25506.2.171.1.3.1.2
hh3cSecHighFaultAlmSlotro
Integer32
.1.3.6.1.4.1.25506.2.171.1.3.1.3
hh3cSecHighFaultAlmDstChassisro
Integer32
.1.3.6.1.4.1.25506.2.171.1.3.1.4
hh3cSecHighFaultAlmDstSlotro
Integer32
.1.3.6.1.4.1.25506.2.171.1.3.1.5
hh3cSecHighFaultAlmChipro
Integer32
.1.3.6.1.4.1.25506.2.171.1.3.1.6
hh3cSecHighFaultAlmInforo
OCTET STRING
.1.3.6.1.4.1.25506.2.171.1.3.1.7
hh3cSecHighFaultAlmTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1.3.2
hh3cSecHighFaultAlmTrapPre
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.1.3.2.0
hh3cSecHighFaultMonChipAlmNotifi
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.171.1.3.2.0.1
hh3cSecHighFaultMonChipAlmResu
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.171.1.3.2.0.2
hh3cSecHighFaultMonHgAlmNotifi
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.171.1.3.2.0.3
hh3cSecHighFaultMonHgAlmResu
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.171.1.3.2.0.4
hh3cSecHighTemperMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.2
hh3cSecHighTemperAlarmVar
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.2.1
hh3cSecHighTemperAlarmChassisro
Integer32
.1.3.6.1.4.1.25506.2.171.2.1.1
hh3cSecHighTemperAlarmSlotro
Integer32
.1.3.6.1.4.1.25506.2.171.2.1.2
hh3cSecHighTemperAlarmHotspotIndxro
Integer32
.1.3.6.1.4.1.25506.2.171.2.1.3
hh3cSecHighTemperAlarmCurTemperro
Integer32
.1.3.6.1.4.1.25506.2.171.2.1.4
hh3cSecHighTemperAlarmLimitro
Integer32
.1.3.6.1.4.1.25506.2.171.2.1.5
hh3cSecHighTemperAlarmTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.2.2
hh3cSecHighTemperAlmTrapPre
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.2.2.0
hh3cSecHighTemperAlarmNotify
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.171.2.2.0.1
hh3cSecHighParityErrorMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.3
hh3cSecHighParityErrorAlarmVar
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.3.1
hh3cSecHighParityErrorAlarmChassisro
Integer32
.1.3.6.1.4.1.25506.2.171.3.1.1
hh3cSecHighParityErrorAlarmSlotro
Integer32
.1.3.6.1.4.1.25506.2.171.3.1.2
hh3cSecHighParityErrorAlarmChipUnitro
Integer32
.1.3.6.1.4.1.25506.2.171.3.1.3
hh3cSecHighParityErrorAlarmTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.3.2
hh3cSecHighParityErrorAlarmTrapPre
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.171.3.2.0
hh3cSecHighParityErrorAlarmNotify
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.171.3.2.0.1

HH3C-SECHIGH-MIB Technical Reference Overview

The HH3C-SECHIGH-MIB SNMP MIB module published by Hangzhou H3C defines 49 managed OID objects, including 25 scalar/column metrics, 0 SNMP tables, and 7 trap/notification events anchored at base OID .1.3.6.1.4.1.25506.2.171. Monitored SNMP traps/notifications include hh3cSecHighFaultMonChipAlmNotifi, hh3cSecHighFaultMonChipAlmResu, hh3cSecHighFaultMonHgAlmNotifi, hh3cSecHighFaultMonHgAlmResu, hh3cSecHighHgMonitorAlarmNotification, hh3cSecHighParityErrorAlarmNotify.

Key OID Definitions in HH3C-SECHIGH-MIB

hh3cSecHighMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.25506.2.171

The private MIB file includes the information on high-end driver products.

hh3cSecHighFaultMonChipAlmNotifiNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.2.171.1.3.2.0.1

This notification is generated when a chip error occurs.

hh3cSecHighFaultMonChipAlmResuNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.2.171.1.3.2.0.2

This notification is generated when a chip error is recovered.

hh3cSecHighFaultMonHgAlmNotifiNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.2.171.1.3.2.0.3

This notification is generated when an Hg error occurs.

hh3cSecHighFaultMonHgAlmResuNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.2.171.1.3.2.0.4

This notification is generated when an Hg error is recovered.

hh3cSecHighHgMonitorAlarmNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.2.171.1.2.0.1

This notification is generated when an HgMonitor alarm is generated.

hh3cSecHighParityErrorAlarmNotifyNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.2.171.3.2.0.1

This notification is generated when a severe parity error occurs.

hh3cSecHighTemperAlarmNotifyNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.2.171.2.2.0.1

This notification is generated when a hotspot's temperature exceeds its power down threshold.

hh3cSecHighFaultAlmChassisInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.3.1.2

Number of the chassis in which error occurs.

hh3cSecHighFaultAlmChipInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.3.1.6

Id of the error chip.

hh3cSecHighFaultAlmDstChassisInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.3.1.4

Number of the destination chassis in which Hg error occurs.

hh3cSecHighFaultAlmDstSlotInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.3.1.5

Number of the destination slot in which Hg error occurs.

hh3cSecHighFaultAlmInfoOCTETaccessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.3.1.7

Details of the alarm notification.

hh3cSecHighFaultAlmSlotInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.3.1.3

Number of the slot in which error occurs.

hh3cSecHighFaultAlmTypeInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.3.1.1

Type of the alarm, 1 represents Hg link status error, 2 represents Hg packet loss error, 3 represents back board E2PROM error, 4 represents board E2PROM error, 5 represents CPLD chip error, 101 to 200 represent FPGA errors.

hh3cSecHighHgMonitorAlarmDstChassisInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.6

Number of the chassis where the destination end of the alarmed link resides.

hh3cSecHighHgMonitorAlarmDstChipInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.8

Number of the chip where the destination end of the alarmed link resides.

hh3cSecHighHgMonitorAlarmDstPortInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.9

Number of the port where the destination end of the alarmed link resides.

hh3cSecHighHgMonitorAlarmDstSlotInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.7

Number of the slot where the destination end of the alarmed link resides.

hh3cSecHighHgMonitorAlarmReasonOCTETaccessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.10

Cause of the alarm.

hh3cSecHighHgMonitorAlarmSrcChassisInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.2

Number of the chassis where the source end of the alarmed link resides.

hh3cSecHighHgMonitorAlarmSrcChipInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.4

Number of the chip where the source end of the alarmed link resides.

hh3cSecHighHgMonitorAlarmSrcPortInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.5

Number of the port where the source end of the alarmed link resides.

hh3cSecHighHgMonitorAlarmSrcSlotInteger32accessible-for-notify
.1.3.6.1.4.1.25506.2.171.1.1.3

Number of the slot where the source end of the alarmed link resides.

More MIBs from Hangzhou H3C

Browse all Hangzhou H3CMIBs →