HH3C-RMON-EXT-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
29
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
29 total| Object Name |
|---|
hh3crmonExtendEventsV2Definition point for pri RMON notifications. OBJECT IDENTIFIER .1.3.6.1.4.1.25506.8.4.0 |
hh3cpririsingAlarmThe SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.8.4.0.1 |
hh3cprifallingAlarmThe SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.8.4.0.2 |
hh3cperformance MODULE-IDENTITY .1.3.6.1.4.1.25506.8.4.4 |
RFC1213-MIB Unknown .1.3.6.1.4.1.25506.8.4.4 |
hh3cprialarmTableA list of alarm entries. SEQUENCE OF Hh3cPriAlarmEntry .1.3.6.1.4.1.25506.8.4.4.1 |
hh3cprialarmEntryA list of parameters that set up a periodic checking
for alarm conditions. For example, an instance of the
alarmValue object might be named alarmValue.8 Hh3cPriAlarmEntry .1.3.6.1.4.1.25506.8.4.4.1.1 |
hh3cprialarmIndexAn index that uniquely identifies an entry in the
alarm table. Each such entry defines a
diagnostic sample at a particular interval
for an object on the device.ro INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.1 |
hh3cprialarmIntervalThe interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be taken in the case of deltaValue
sampling - the interval should be set short enough
that the sampled variable is very unlikely to
increase or decrease by more than 2^31 - 1 during
a single sampling interval.
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.2 |
hh3cprialarmVariableThe object identifier of the particular variable to be
sampled. Only variables that resolve to an ASN.1 primitive
type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
Gauge, or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value of
this object to identify only those objects that exist
in a particular MIB view. Because there is thus no
acceptable means of restricting the read access that
could be obtained through the alarm mechanism, the
probe must only grant write access to this object in
those views that have read access to all objects on
the probe.
During a set operation, if the supplied variable name is
not available in the selected MIB view, a badValue error
must be returned. If at any time the variable name of
an established alarmEntry is no longer available in the
selected MIB view, the probe must change the status of
this alarmEntry to invalid(4).
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.8.4.4.1.1.3 |
hh3cprialarmSympolrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.8.4.4.1.1.4 |
hh3cprialarmSampleTypeThe method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
absoluteValue(1), the value of the selected variable
will be compared directly with the thresholds at the
end of the sampling interval. If the value of this
object is deltaValue(2), the value of the selected
variable at the last sample will be subtracted from
the current value, and the difference compared with
the thresholds.
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw Enumeration .1.3.6.1.4.1.25506.8.4.4.1.1.5 |
hh3cprialarmValueThe value of the statistic during the last sampling
period. For example, if the sample type is deltaValue,
this value will be the difference between the samples
at the beginning and end of the period. If the sample
type is absoluteValue, this value will be the sampled
value at the end of the period.
This is the value that is compared with the rising and
falling thresholds.
The value during the current sampling period is not
made available until the period is completed and will
remain available until the next period completes.ro INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.6 |
hh3cprialarmStartupAlarmThe alarm that may be sent when this entry is first
set to valid. If the first sample after this entry
becomes valid is greater than or equal to the
risingThreshold and alarmStartupAlarm is equal to
risingAlarm(1) or risingOrFallingAlarm(3), then a single
rising alarm will be generated. If the first sample
after this entry becomes valid is less than or equal
to the fallingThreshold and alarmStartupAlarm is equal
to fallingAlarm(2) or risingOrFallingAlarm(3), then a
single falling alarm will be generated.
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw Enumeration .1.3.6.1.4.1.25506.8.4.4.1.1.7 |
hh3cprialarmRisingThresholdA threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold,
and the value at the last sampling interval was less than
this threshold, a single event will be generated.
A single event will also be generated if the first
sample after this entry becomes valid is greater than or
equal to this threshold and the associated
alarmStartupAlarm is equal to risingAlarm(1) or
risingOrFallingAlarm(3).
After a rising event is generated, another such event
will not be generated until the sampled value
falls below this threshold and reaches the
alarmFallingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.8 |
hh3cprialarmFallingThresholdA threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold,
and the value at the last sampling interval was greater than
this threshold, a single event will be generated.
A single event will also be generated if the first
sample after this entry becomes valid is less than or
equal to this threshold and the associated
alarmStartupAlarm is equal to fallingAlarm(2) or
risingOrFallingAlarm(3).
After a falling event is generated, another such event
will not be generated until the sampled value
rises above this threshold and reaches the
alarmRisingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.9 |
hh3cprialarmRisingEventIndexThe index of the eventEntry that is
used when a rising threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.10 |
hh3cprialarmFallingEventIndexThe index of the eventEntry that is
used when a falling threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
alarmStatus object is equal to valid(1).rw INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.11 |
hh3cprialarmStatCyclerw INTEGER .1.3.6.1.4.1.25506.8.4.4.1.1.12 |
hh3cprialarmStatTyperw Enumeration .1.3.6.1.4.1.25506.8.4.4.1.1.13 |
hh3cprialarmOwnerThe entity that configured this entry and is therefore
using the resources assigned to it.rw OwnerString (IF-MIB) .1.3.6.1.4.1.25506.8.4.4.1.1.14 |
hh3cprialarmStatusThe status of this alarm entry.rw EntryStatus (RMON-MIB) .1.3.6.1.4.1.25506.8.4.4.1.1.15 |
hh3crmonEnableTableA list of enable rmon entries. SEQUENCE OF Hh3crmonEnableEntry .1.3.6.1.4.1.25506.8.4.5 |
hh3crmonEnableEntryA list of parameters that set up a hh3crmonEnableTable Hh3crmonEnableEntry .1.3.6.1.4.1.25506.8.4.5.1 |
hh3crmonEnableIfIndexSpecify an interface to enable rmon.ro INTEGER .1.3.6.1.4.1.25506.8.4.5.1.1 |
hh3crmonEnableStatusSpecify an interface to enable rmon.rw Enumeration .1.3.6.1.4.1.25506.8.4.5.1.2 |
hh3cTrapDestTableDefines the trap destination Extend Table for providing, via SNMP,
the capability of configure a trap dest. SEQUENCE OF Hh3cTrapDestEntry .1.3.6.1.4.1.25506.8.4.6 |
hh3cTrapDestEntryDefines an entry in the hh3cTrapDestTable. Hh3cTrapDestEntry .1.3.6.1.4.1.25506.8.4.6.1 |
hh3cTrapDestVersionThe version for trap destination.
This object may not be modified if the associated
trapDestStatus object is equal to active(1).rw Enumeration .1.3.6.1.4.1.25506.8.4.6.1.1 |