Home/Catalog/HH3C-REDUNDANCY-POWER-MIB

HH3C-REDUNDANCY-POWER-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for HH3C-REDUNDANCY-POWER-MIB.

Main OID:
hh3credundancyPower.1.3.6.1.4.1.25506.8.36.4
15
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

15 total
Object Name
hh3credundancyPower
MODULE-IDENTITY
.1.3.6.1.4.1.25506.8.36.4
hh3credundancyPowerTable
SEQUENCE OF Hh3cRedundancyPowerEntry
.1.3.6.1.4.1.25506.8.36.4.1
hh3credundancyPowerEntry
Hh3cRedundancyPowerEntry
.1.3.6.1.4.1.25506.8.36.4.1.1
hh3credundancyPowerIDro
INTEGER
.1.3.6.1.4.1.25506.8.36.4.1.1.1
hh3credundancyPowerStatusro
Enumeration
.1.3.6.1.4.1.25506.8.36.4.1.1.2
hh3credundancyPowerPreviousStatusro
Enumeration
.1.3.6.1.4.1.25506.8.36.4.1.1.3
hh3cpowerTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.36.4.2
hh3cpowerStatusChangedTrap
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.8.36.4.2.1
hh3credundancyFan
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.36.5
hh3credundancyFanTable
SEQUENCE OF Hh3cRedundancyFanEntry
.1.3.6.1.4.1.25506.8.36.5.1
hh3credundancyFanEntry
Hh3cRedundancyFanEntry
.1.3.6.1.4.1.25506.8.36.5.1.1
hh3credundancyFanIDro
INTEGER
.1.3.6.1.4.1.25506.8.36.5.1.1.1
hh3credundancyFanStatusro
Enumeration
.1.3.6.1.4.1.25506.8.36.5.1.1.2
hh3cfanTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.36.5.2
hh3cfanStatusChangedTrap
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.8.36.5.2.1

HH3C-REDUNDANCY-POWER-MIB Technical Reference Overview

The HH3C-REDUNDANCY-POWER-MIB SNMP MIB module published by Hangzhou H3C defines 15 managed OID objects, including 5 scalar/column metrics, 2 SNMP tables, and 2 trap/notification events anchored at base OID .1.3.6.1.4.1.25506.8.36.4. Key tabular structures include hh3credundancyFanTable, hh3credundancyPowerTable. Monitored SNMP traps/notifications include hh3cfanStatusChangedTrap, hh3cpowerStatusChangedTrap.

Key OID Definitions in HH3C-REDUNDANCY-POWER-MIB

hh3credundancyFanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.25506.8.36.5.1

The table describles the attributes of every power unit.

hh3credundancyPowerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.25506.8.36.4.1

The table describles the attributes of every power unit.

hh3cfanStatusChangedTrapNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.8.36.5.2.1

This trap is generated when the satus of a power unit is changed.

hh3cpowerStatusChangedTrapNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.8.36.4.2.1

This trap is generated when the satus of a power unit is changed.

hh3credundancyFanEntryHh3cRedundancyFanEntrynot-accessible
.1.3.6.1.4.1.25506.8.36.5.1.1

Each entry contains the attributes associated with a single power unit entity.

hh3credundancyFanIDINTEGERread-only
.1.3.6.1.4.1.25506.8.36.5.1.1.1

The identify of power uinit. This is also the index of this table.

hh3credundancyFanStatusINTEGERread-only
.1.3.6.1.4.1.25506.8.36.5.1.1.2

The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail'

hh3credundancyPowerEntryHh3cRedundancyPowerEntrynot-accessible
.1.3.6.1.4.1.25506.8.36.4.1.1

Each entry contains the attributes associated with a single power unit entity.

hh3credundancyPowerIDINTEGERread-only
.1.3.6.1.4.1.25506.8.36.4.1.1.1

The identify of power uinit. This is also the index of this table.

hh3credundancyPowerPreviousStatusINTEGERread-only
.1.3.6.1.4.1.25506.8.36.4.1.1.3

The last status of every redundancy power unit

hh3credundancyPowerStatusINTEGERread-only
.1.3.6.1.4.1.25506.8.36.4.1.1.2

The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail'

More MIBs from Hangzhou H3C

Browse all Hangzhou H3CMIBs →