Home/Catalog/HH3C-LswMix-MIB

HH3C-LswMix-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for HH3C-LswMix-MIB.

14
Objects
Active
Status
1
Dependencies

Imported Objects

Objects

14 total
Object Name
hh3c
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506
hh3cRhw
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8
hh3clswCommon
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.35
hh3cLswMix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.35.17
hh3cLswLastSwitchDatero
INTEGER
.1.3.6.1.4.1.25506.8.35.17.1
hh3cLswLastSwitchTimero
INTEGER
.1.3.6.1.4.1.25506.8.35.17.2
hh3cLswMpuSwitchsNumro
INTEGER
.1.3.6.1.4.1.25506.8.35.17.3
hh3cLswMpuSwitchro
Enumeration
.1.3.6.1.4.1.25506.8.35.17.4
hh3cLswXSlotTablero
SEQUENCE OF Hh3cLswXSlotEntry
.1.3.6.1.4.1.25506.8.35.17.5
hh3cLswXSlotEntryro
Hh3cLswXSlotEntry
.1.3.6.1.4.1.25506.8.35.17.5.1
hh3cLswMainCardBoardStatusro
Enumeration
.1.3.6.1.4.1.25506.8.35.17.5.1.1
hh3cLswCrossBarStatusro
Enumeration
.1.3.6.1.4.1.25506.8.35.17.5.1.2
hh3csMixTrapMib
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.35.17.10
hh3cSlaveSwitchOver
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.8.35.17.10.0.1

HH3C-LswMix-MIB Technical Reference Overview

The HH3C-LswMix-MIB SNMP MIB module published by Hangzhou H3C defines 14 managed OID objects, including 6 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events. Key tabular structures include hh3cLswXSlotTable. Monitored SNMP traps/notifications include hh3cSlaveSwitchOver.

Key OID Definitions in HH3C-LswMix-MIB

hh3cLswXSlotTableSEQUENCEread-only
.1.3.6.1.4.1.25506.8.35.17.5

The source main table.

hh3cSlaveSwitchOverNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.25506.8.35.17.10.0.1

An hh3cSlaveSwitchOver trap signifies that the action of standby mpu switching to master has completed.

hh3cLswLastSwitchDateINTEGERread-only
.1.3.6.1.4.1.25506.8.35.17.1

This object indicates the date of the most recent change to the mpu(Main Processing Unit).

hh3cLswLastSwitchTimeINTEGERread-only
.1.3.6.1.4.1.25506.8.35.17.2

This object indicates the time of the most recent change to the mpu.

hh3cLswMpuSwitchINTEGERread-only
.1.3.6.1.4.1.25506.8.35.17.4

Setting this object will immediately switch the standby mpu to master mpu. Read is not supported.

hh3cLswMpuSwitchsNumINTEGERread-only
.1.3.6.1.4.1.25506.8.35.17.3

This object indicates the total times of the mpu switched since the system start up.

hh3cLswCrossBarStatusINTEGERread-only
.1.3.6.1.4.1.25506.8.35.17.5.1.2

The value describes whether the crossbar is master or standby. It is master when it's in the master mpu board, standby when in the standby mpu. But both crossbars in mpus are master when the device in load-balance mode.

hh3cLswMainCardBoardStatusINTEGERread-only
.1.3.6.1.4.1.25506.8.35.17.5.1.1

The value describes whether the board is master, standby or process. master and standby are the possible states for the mpu, while process indicates the state of lpu(Line Processing Unit)

hh3cLswXSlotEntryHh3cLswXSlotEntryread-only
.1.3.6.1.4.1.25506.8.35.17.5.1

An entry in the source main table.

More MIBs from Hangzhou H3C

Browse all Hangzhou H3CMIBs →