Home/Catalog/HH3C-ENTITY-EXT-MIB

HH3C-ENTITY-EXT-MIB

The private MIB file includes the general extent information of the device.
Main OID:
hh3cEntityExtend.1.3.6.1.4.1.25506.2.6
129
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

129 total
Object Name
hh3cEntityExtendThe private MIB file includes the general extent information of the device.
MODULE-IDENTITY
.1.3.6.1.4.1.25506.2.6
hh3cEntityExtObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.1
hh3cEntityExtState
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.1.1
hh3cEntityExtStateTableThis table contains one row per physical entity, There is always at least one row for an 'overall' physical entity. The information in each row may be not include all the object in this table, because of the entity need not some of the information here.
SEQUENCE OF Hh3cEntityExtStateEntry
.1.3.6.1.4.1.25506.2.6.1.1.1
hh3cEntityExtStateEntryThe information about a particular physical entity.
Hh3cEntityExtStateEntry
.1.3.6.1.4.1.25506.2.6.1.1.1.1
hh3cEntityExtPhysicalIndexThe index of hh3cEntityExtStateTable. This index is identical to entPhysicalIndex in ENTITY-MIBro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.1
hh3cEntityExtAdminStatusThe administrative state for this object.rw
Hh3cAdminState
.1.3.6.1.4.1.25506.2.6.1.1.1.1.2
hh3cEntityExtOperStatusThe operate state for this object.ro
Hh3cOperState
.1.3.6.1.4.1.25506.2.6.1.1.1.1.3
hh3cEntityExtStandbyStatusThis object is used for monitoring standby status. Not all entities support this object.ro
Hh3cStandbyStatus
.1.3.6.1.4.1.25506.2.6.1.1.1.1.4
hh3cEntityExtAlarmLightThe alarm status for this entity. It does not include the severity of alarms raised on child components. In this condition, there will be a alarm light on the entity, the object should have the same status with it.ro
Hh3cAlarmStatus
.1.3.6.1.4.1.25506.2.6.1.1.1.1.5
hh3cEntityExtCpuUsageThe CPU usage for this entity. Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the entity.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.6
hh3cEntityExtCpuUsageThresholdThe threshold for the CPU usage. When the CPU usage exceeds the threshold, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.7
hh3cEntityExtMemUsageThe memory usage for the entity. This object indicates what percent of memory are used.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.8
hh3cEntityExtMemUsageThresholdThe threshold for the Memory usage, When the memory usage exceeds the threshold, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.9
hh3cEntityExtMemSizeThe size of memory for the entity. If the amount of memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.ro
Unsigned32 UNITS "bytes"
.1.3.6.1.4.1.25506.2.6.1.1.1.1.10
hh3cEntityExtUpTimeThe uptime for the entity. The meaning of uptime is when the entity is up, and the value of the object will add 1 seconds while the entity is running.ro
Integer32 UNITS "seconds"
.1.3.6.1.4.1.25506.2.6.1.1.1.1.11
hh3cEntityExtTemperatureThe temperature for the entity.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.12
hh3cEntityExtTemperatureThresholdThe threshold for the temperature. When the temperature exceeds the threshold, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.13
hh3cEntityExtVoltageThe voltage for the entity.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.14
hh3cEntityExtVoltageLowThresholdThe low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.15
hh3cEntityExtVoltageHighThresholdThe high-threshold for the voltage. When voltage greater than high-threshold, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.16
hh3cEntityExtCriticalTemperatureThresholdThe threshold for the critical Temperature. When temperature exceeds the critical temperature, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.17
hh3cEntityExtMacAddressMAC Address of the entity.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.25506.2.6.1.1.1.1.18
hh3cEntityExtErrorStatusIndicate the error state of this entity object. Now it only supports Port, general power supply, RPS power supply and board/Subcard. It may have one of these values. The following four values can be used for all kinds of entities. notSupported(1) means this entity cannot support this function. normal(2) means the statement of this entity is normal. for ports, it doesn't differentiate 10M/s, 100M/s, 1000M/s, duplex and half-duplex. For fan, power supply and board-Subcard, it means their states are normal. postFailure(3) means the entity fails to POST. entityAbsent(4) means the entity is absent now. The following values is depended on the entity. For Port entities, it may have the following values. If its POST is failure, then the value of the instance will be postFailure(3), otherwise the value will be normal(2). If enable power supply over Ethernet on this port is failure, the value of this instance will be poeError(11), otherwise it will be normal(2). For stack port, if it connects to another stack port normally, and these two units merge into one stack, then the value of this instance will be normal(2). If something wrong occurs and the unit cannot merge into stack, the value of this instance will be stackPortFailed(23). If the stack port forms resilient daisy chain with another stack port on the other unit, the value of this instance will be stackPortBlocked(22). For SFP ports, if it fail to receive, the value of this instance will be sfpRecvError(31), if it fail to send, the value is sfpSendError(32), if it fail to send and receive, the value is sfpBothError(33), otherwise it will be normal(2). fanError(41) means that the fan stops working. psuError(51) means that the Power Supply Unit is in the state of fault. rpsError(61) means the RPS is in the state of fault. moduleFaulty(71) means the Module is in the state of fault. sensorError(81) means the sensor is in the state of fault. hardwareFaulty(91) means the hardware of specified entity is in the state of fault. NMS must be compatible with the states which may be added in the future.ro
Enumeration
.1.3.6.1.4.1.25506.2.6.1.1.1.1.19
hh3cEntityExtCpuMaxUsageThe maximal CPU usage for the entity in the period of time.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.20
hh3cEntityExtLowerTemperatureThresholdThe threshold for the lower Temperature. When temperature runs under the threshold, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.21
hh3cEntityExtShutdownTemperatureThresholdThe threshold for the shutdown Temperature. When temperature exceeds the threshold, a notification will be sent and the entity will be shutdown.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.22
hh3cEntityExtPhyMemSizeThe memory size of entity. This is the physical attribute of entity.ro
Unsigned32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.23
hh3cEntityExtPhyCpuFrequencyThe CPU frequency of entity. Unit of measure is MHZ.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.24
hh3cEntityExtFirstUsedDateThe first used date of the entity.ro
DateAndTime
.1.3.6.1.4.1.25506.2.6.1.1.1.1.25
hh3cEntityExtCpuAvgUsageThe average CPU usage for the entity in a period of time.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.26
hh3cEntityExtMemAvgUsageThe average memory usage for the entity in a period of time.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.27
hh3cEntityExtMemTypeThe memory type of entity.ro
OCTET STRING
.1.3.6.1.4.1.25506.2.6.1.1.1.1.28
hh3cEntityExtCriticalLowerTemperatureThresholdThe threshold for the critical Temperature. When temperature exceeds the critical lower temperature, a notification will be sent.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.29
hh3cEntityExtShutdownLowerTemperatureThresholdThe threshold for the shutdown Temperature. When temperature exceeds the lower threshold, a notification will be sent and the entity will be shutdown.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.30
hh3cEntityExtCpuUsageRecoverThresholdThe recover threshold for the CPU usage. When the CPU usage falls down to the threshold, a notification is sent. The hh3cEntityExtCpuUsageRecoverThreshold must be less than or equal to the hh3cEntityExtCpuUsageThreshold.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.31
hh3cEntityExtMemSizeRevSize of memory space for the entity. This node is used to replace hh3cEntityExtMemSize.ro
CounterBasedGauge64 UNITS "bytes"
.1.3.6.1.4.1.25506.2.6.1.1.1.1.32
hh3cEntityExtCpuUsageIn1MinuteThe CPU usage in last one minute for this entity. Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the entity.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.33
hh3cEntityExtCpuUsageIn5MinutesThe CPU usage in last five minutes for this entity. Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the entity.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.1.1.1.34
hh3cEntityExtManu
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.1.2
hh3cEntityExtManuTableThe table about device manufacture information.
SEQUENCE OF Hh3cEntityExtManuEntry
.1.3.6.1.4.1.25506.2.6.1.2.1
hh3cEntityExtManuEntryThe device manufacture information about a particular physical entity.
Hh3cEntityExtManuEntry
.1.3.6.1.4.1.25506.2.6.1.2.1.1
hh3cEntityExtManuPhysicalIndexThe index of hh3cEntityExtManuTable. This index is identical to entPhysicalIndex in ENTITY-MIB.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.2.1.1.1
hh3cEntityExtManuSerialNumManufacture serial number. The manufacture serial number of the entity such as chassis, module, and so on. It is got from the device when manufacturing. For low level box-device, the manufacture serial number is the device-number of System Control Board(SCB for short), it is written into the SCB directly; for middle level or high level frame-device, the manufacture serial number is the device-numbers of SCB and Service Board, because the SCB, Service Board and chassis are separate to sale and the device-number of chassis cannot be written into board.ro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.25506.2.6.1.2.1.1.2
hh3cEntityExtManuBuildInfoDevice version information. The device version information of the entity such as chassis, module, and so on. It consists of software version information and hardware version information.ro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.25506.2.6.1.2.1.1.3
hh3cEntityExtManuBOMDevice BOM code. The device BOM code of the entity such as chassis, module, and so on. It is the component code of ERP system, which can be disassembled from device-number.ro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.25506.2.6.1.2.1.1.4
hh3cEntityExtMacAddressCountMAC address count. The count of MAC addresses of the entity, such as chassis, module, or port, and so on.ro
Unsigned32
.1.3.6.1.4.1.25506.2.6.1.2.1.1.5
hh3cEntityExtPower
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.1.3
hh3cEntityExtPowerTableThis table describes the power information of all the physical entity on the device, such as the fans, the subcards, the boards, etc.
SEQUENCE OF Hh3cEntityExtPowerEntry
.1.3.6.1.4.1.25506.2.6.1.3.1
hh3cEntityExtPowerEntryThe entity power information about a particular physical entity.
Hh3cEntityExtPowerEntry
.1.3.6.1.4.1.25506.2.6.1.3.1.1
hh3cEntityExtPowerPhysicalIndexThe index of hh3cEntityExtPowerTable. This index is identical to entPhysicalIndex in ENTITY-MIB.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.3.1.1.1
hh3cEntityExtNominalPowerThe nominal power of the entity expressed in milliWatts.ro
Gauge32
.1.3.6.1.4.1.25506.2.6.1.3.1.1.2
hh3cEntityExtCurrentPowerThe measured usage power of the entity expressed in milliWatts.ro
Gauge32
.1.3.6.1.4.1.25506.2.6.1.3.1.1.3
hh3cEntityExtAveragePowerThe average power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.3.1.1.4
hh3cEntityExtPeakPowerThe peak power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned.rw
Integer32
.1.3.6.1.4.1.25506.2.6.1.3.1.1.5
hh3cProcessObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.1.4
hh3cProcessTableThe Table describes the information about a particular process, namely a task.
SEQUENCE OF Hh3cProcessEntry
.1.3.6.1.4.1.25506.2.6.1.4.1
hh3cProcessEntryThe information about a particular process, namely a task.
Hh3cProcessEntry
.1.3.6.1.4.1.25506.2.6.1.4.1.1
hh3cProcessIDThis object indicates the identifier of process, namely task ID in system.ro
Unsigned32
.1.3.6.1.4.1.25506.2.6.1.4.1.1.1
hh3cProcessNameThis object indicates the process name.ro
DisplayString
.1.3.6.1.4.1.25506.2.6.1.4.1.1.2
hh3cProcessUtil5MinThis object provides a general idea of how busy a process caused the processor to be over a 5 minute period. The ratio is calculated by the overall CPU usage caused by the process.ro
Unsigned32
.1.3.6.1.4.1.25506.2.6.1.4.1.1.3
hh3cEntityExtVoltageObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.1.5
hh3cEntityExtVoltageTableThe table describes the voltage information of the voltage sensor entities on the device.
SEQUENCE OF Hh3cEntityExtVoltageEntry
.1.3.6.1.4.1.25506.2.6.1.5.1
hh3cEntityExtVoltageEntryThe voltage information of the voltage sensor entity.
Hh3cEntityExtVoltageEntry
.1.3.6.1.4.1.25506.2.6.1.5.1.1
hh3cEntityExtCurrentVoltageThe current voltage in millivolts of the voltage sensor entity.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.5.1.1.1
hh3cEntityExtNominalVoltageThe nominal voltage in millivolts of the voltage sensor entity.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.5.1.1.2
hh3cEntityExtVoltageStateThe voltage state of the voltage sensor entity.ro
Enumeration
.1.3.6.1.4.1.25506.2.6.1.5.1.1.3
hh3cEntityExtVoltageMajorLowThresholdThe low threshold for the voltage sensor entity. When the voltage is lower than the threshold, a notification will be sent.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.5.1.1.4
hh3cEntityExtVoltageFatalLowThresholdThe fatal low voltage threshold for the voltage sensor entity. When the voltage is lower than the threshold, a notification will be sent.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.5.1.1.5
hh3cEntityExtVoltageMajorHighThresholdThe high threshold for the voltage sensor entity. When the voltage is higher than the threshold, a notification will be sent.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.5.1.1.6
hh3cEntityExtVoltageFatalHighThresholdThe fatal high threshold for the voltage sensor entity. When the voltage is higher than the threshold, a notification will be sent.ro
Integer32
.1.3.6.1.4.1.25506.2.6.1.5.1.1.7
hh3cEntityExtTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.2
hh3cEntityExtTrapsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.2.0
hh3cEntityExtTemperatureThresholdNotificationThe hh3cEntityExtTemperatureThresholdNotification indicates the temperature exceeded the threshold. In this condition, user should check the status and the environment of the entity, sometimes it happens because of the failure of air-condition.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.1
hh3cEntityExtVoltageLowThresholdNotificationThe hh3cEntityExtVoltageLowThresholdNotification indicates the voltage is lower than the threshold. If the voltage is lower too much than the entity needs, the entity will halt.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.2
hh3cEntityExtVoltageHighThresholdNotificationThe hh3cEntityExtVoltageHighThresholdNotification indicates the voltage is higher than the threshold. If the voltage is higher too much than the entity needs, The entity may be damaged by the high voltage.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.3
hh3cEntityExtCpuUsageThresholdNotficationThe hh3cEntityExtCpuUsageThresholdNotfication indicates the entity is overloaded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.4
hh3cEntityExtMemUsageThresholdNotificationThe hh3cEntityExtMemUsageThresholdNotification indicates the entity is overloaded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.5
hh3cEntityExtOperEnabledThe trap indicates the entity is operable at present.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.6
hh3cEntityExtOperDisabledThe trap indicates the entity is not operable at present.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.7
hh3cEntityExtCriticalTemperatureThresholdNotificationThe hh3cEntityExtCriticalTemperatureThresholdNotification indicates the temperature exceeds the critical temperature. In this condition, user should check the status and the environment of the entity, sometimes it happens because of the failure of air-condition.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.8
hh3cEntityExtSFPAlarmOnThe trap is generated when the SFP module fails or runs abnormally for some particular reason.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.9
hh3cEntityExtSFPAlarmOffThe trap is generated when the SFP module restores to normal status.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.10
hh3cEntityExtSFPPhonyThis module is NOT sold by authorized manufacturer. The normal function of the device or assume the maintenance responsibility thereof will NOT be guaranteed. The trap is generated periodically after a phony module has been found.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.11
hh3cEntityInsertThe trap is generated when a removable entity inserting to device.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.12
hh3cEntityRemoveThe trap is generated when a removable entity removing from device.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.13
hh3cEntityExtForcedPowerOffThe trap indicates the entity is forced to power off.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.14
hh3cEntityExtForcedPowerOnThe trap indicates the entity is forced to power on.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.15
hh3cEntityExtFaultAlarmOnThe trap indicates a fault occurs on the specified entity.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.16
hh3cEntityExtFaultAlarmOffThe trap indicates a fault disappears on the specified entity.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.17
hh3cEntityExtResourceLackThe trap indicates that a kind of resource is not enough on the specified entity.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.18
hh3cEntityExtResourceEnoughThe trap indicates that the entity recovers from the status of no enough resource.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.19
hh3cEntityExtTemperatureLowerThe trap indicates the temperature of a specified entity is under the lower threshold. In this condition, user should check the status and the environment of the entity, sometimes it goes wrong for some reason.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.20
hh3cEntityExtTemperatureTooUpThe trap indicates the temperature of a specified entity exceeded the shutdown threshold. In this condition, user should check the status and the environment of the entity, sometimes it goes wrong for some reason.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.21
hh3cEntityExtTemperatureNormalThe trap indicates the temperature of a specified entity recover from abnormal status.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.22
hh3cEntityExternalAlarmOccurThe trap is generated when the monitored device connected to the specified entity fails.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.23
hh3cEntityExternalAlarmRecoverThe trap is generated when the failed device connected to the specified entity returns to normal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.24
hh3cEntityExtCpuUsageThresholdRecoverThe trap indicates the CPU usage descends the threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.25
hh3cEntityExtMemUsageThresholdRecoverThe trap indicates the memory usage descends the threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.26
hh3cEntityExtMemAllocatedFailedThe trap indicates the memory allocated failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.27
hh3cEntityExtECCParityAlarmThe trap indicates the ECC(Error Correction Code) parity error alarm.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.28
hh3cEntityExtCritLowerTempThresholdNotificationThe hh3cEntityExtCritLowerTempThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity will halt.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.29
hh3cEntityExtTemperatureTooLowThe hh3cEntityExtTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity halts now.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.30
hh3cEntityExtFanDirectionNotPreferredThis trap indicates the specified fan's direction does not accord with preferred. The two parameters indicate the entity index and physical name of fan.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.31
hh3cEntityExtFanDirectionNotAccordThis trap indicates the direction of fans does not accord with each other. The two parameters indicate the parent entity of the fans.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.32
hh3cEntityExtSFPInvalidThe transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transceiver. The transceiver module will be invalidated in days. Please replace it with a compatible one as soon as possible. The trap is generated periodically after a phony transceiver module has been found.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.33
hh3cEntityExtSFPInvalidNowThis transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transceiver. The trap is generated after a phony transceiver module has been found.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.34
hh3cEntityExtMemUsageThresholdOverTrapThis trap indicates that the memory usage of the entity is overloaded. This trap is used to replace hh3cEntityExtMemUsageThresholdNotification.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.35
hh3cEntityExtMemUsageThresholdRecoverTrapThis trap indicates that the memory usage decreased below the threshold. This trap is used to replace hh3cEntityExtMemUsageThresholdRecover.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.36
hh3cEntityExtVoltageNormalThis trap indicates that the voltage recovers to normal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.37
hh3cEntityExtVoltageLowerThis trap indicates that the voltage is lower than the low threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.38
hh3cEntityExtVoltageTooLowThis trap indicates that the voltage is lower than the fatal low threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.39
hh3cEntityExtVoltageHigherThis trap indicates that the voltage is higher than the high threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.40
hh3cEntityExtVoltageTooHighThis trap indicates that the voltage is higher than the fatal high threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.41
hh3cEntityExtSFPAlarmOnExThe trap is generated when the SFP module fails or runs abnormally for some particular reason. This trap is used to replace hh3cEntityExtSFPAlarmOn.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.42
hh3cEntityExtSFPAlarmOffExThe trap is generated when the SFP module is restored to normal status. This trap is used to replace hh3cEntityExtSFPAlarmOff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.2.6.2.0.43
hh3cEntityExtTrapsInfor
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.2.1
hh3cEntityExtTrapDescriptionThe information of trap.ro
SnmpAdminString
.1.3.6.1.4.1.25506.2.6.2.1.1
hh3cEntityExtECCParityAlarmStatusECC parity error.ro
Enumeration
.1.3.6.1.4.1.25506.2.6.2.1.2
hh3cEntityExtSFPInvalidInDaysThe days when the transceiver module is still valid, but after those days, it will be invalidated.ro
Integer32
.1.3.6.1.4.1.25506.2.6.2.1.3
hh3cEntityExtFirstTrapTimeRepresents the first trap time.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.25506.2.6.2.1.4
hh3cEntityExtConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.3
hh3cEntityExtCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.3.1
hh3cEntityExtComplianceThe compliance statement for systems supporting this MIB.
Unknown
.1.3.6.1.4.1.25506.2.6.3.1.1
hh3cEntityExtGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.2.6.3.2
hh3cEntityExtGroupEntity Extend group.
Unknown
.1.3.6.1.4.1.25506.2.6.3.2.1
hh3cEntityExtNotificationGroupEntity Extend Notification group.
Unknown
.1.3.6.1.4.1.25506.2.6.3.2.2
hh3cEntityExtManuGroupStandard Device Manufacture Information group.
Unknown
.1.3.6.1.4.1.25506.2.6.3.2.3
hh3cEntityExtPowerGroupStandard Entity Power Information group.
Unknown
.1.3.6.1.4.1.25506.2.6.3.2.4
HH3C-ENTITY-EXT-MIB - SNMP MIB Reference | MIBs Explorer