HH3C-CATV-TRANSCEIVER-MIB
AI MIB Summary
The HH3C-CATV-TRANSCEIVER-MIB enables SNMP-based monitoring and configuration of CATV transceiver modules on H3C network devices, specifically exposing operational parameters such as optical power levels, bias currents, temperature, and voltage status for community antenna television infrastructure.
The objects in this MIB module are used to manage and display common configuration for CATV(Community Antenna Television) transceiver module.
Main OID:
hh3cCATVTransceiver.1.3.6.1.4.1.25506.2.94
20
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
20 total| Object Name |
|---|
hh3cCATVTransceiverThe objects in this MIB module are used to manage and display common configuration for CATV(Community Antenna Television) transceiver module. MODULE-IDENTITY .1.3.6.1.4.1.25506.2.94 |
hh3cCATVTransStatus OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.94.1 |
hh3cCATVTransStatusScalarObjects OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.94.1.1 |
hh3cCATVTransStateThe state of CATV transceiver.ro Enumeration .1.3.6.1.4.1.25506.2.94.1.1.1 |
hh3cCATVTransInputPwrThe input power of CATV transceiver. If transceiver is not on site, the value should be zero.ro Integer32 UNITS "dbm" .1.3.6.1.4.1.25506.2.94.1.1.2 |
hh3cCATVTransOutputLevelThe output level of CATV transceiver. If transceiver is not on site, the value should be zero.ro Integer32 UNITS "dbuv" .1.3.6.1.4.1.25506.2.94.1.1.3 |
hh3cCATVTransTemperatureThe temperature of CATV transceiver. If transceiver is not on site, the value should be zero.ro Integer32 UNITS "centigrade" .1.3.6.1.4.1.25506.2.94.1.1.4 |
hh3cCATVTransceiverMan OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.94.2 |
hh3cCATVTransCtrlScalarObjects OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.94.2.1 |
hh3cCATVTransInputPwrLowerThrA threshold for the CATV transceiver's input power. When the input power of CATV transceiver is lower than threshold, a trap should be generated.rw Integer32 UNITS "dbm" .1.3.6.1.4.1.25506.2.94.2.1.1 |
hh3cCATVTransOutputLvlLowerThrA threshold for the CATV transceiver's output level. When the output level of CATV transceiver is lower than threshold, a trap should be generated.rw Integer32 UNITS "dbuv" .1.3.6.1.4.1.25506.2.94.2.1.2 |
hh3cCATVTransTempratureUpperThrA threshold for the CATV transceiver's temperature. When the temperature of CATV transceiver is higher than threshold, a trap should be generated.rw Integer32 UNITS "" .1.3.6.1.4.1.25506.2.94.2.1.3 |
hh3cCATVTansTrap OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.94.3 |
hh3cCATVTransTrapPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.25506.2.94.3.0 |
hh3cCATVTransInputPwrTrapA hh3cCATVTransInputPwrTrap notification is sent when the input power of CATV transceiver is lower than the threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.94.3.0.1 |
hh3cCATVTransInputPwrReTrapA hh3cCATVTransInputPwrReTrap notification is sent when the input power of CATV transceiver recovered from the last trap. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.94.3.0.2 |
hh3cCATVTransOutputLvlTrapA hh3cCATVTransOutputLvlTrap notification is sent when the output level of CATV transceiver is lower than the threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.94.3.0.3 |
hh3cCATVTransOutputLvlReTrapA hh3cCATVTransOutputLvlReTrap notification is sent when the output level of CATV transceiver recovered from the last trap. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.94.3.0.4 |
hh3cCATVTransTemperatureTrapA hh3cCATVTransTemperatureTrap notification is sent when the temperature of CATV transceiver is higher than the threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.94.3.0.5 |
hh3cCATVTransTemperatureReTrapA hh3cCATVTransTemperatureReTrap notification is sent when the temperature of CATV transceiver recovered from the last trap. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.2.94.3.0.6 |