Detailed view of the defined objects, syntax rules, and hierarchical paths.

136
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

136 total
Object Name
codex
OBJECT IDENTIFIER
.1.3.6.1.4.1.449
RFC1155-SMI
Unknown
.1.3.6.1.4.1.449
cdxProductSpecific
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2
cdx6500
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1
cdx6500Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2
cdx6500CfgProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1
cdx6500PCTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.1
cdx6500PCTFRDTEPortTableAll of the configuration parameters relevant to the Frame Relay DTE Port table.
SEQUENCE OF Cdx6500PCTFRDTEPortEntry
.1.3.6.1.4.1.449.2.1.2.1.1.5
cdx6500PCTFRDTEPortEntryA row of FRI Port configuration parameters.
Cdx6500PCTFRDTEPortEntry
.1.3.6.1.4.1.449.2.1.2.1.1.5.1
cdx6500frdtepCfgPortNumSpecifies the Port number for the Frame Relay Interface port you are selecting.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.1
cdx6500frdtepConnectionTypeSpecify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required dtr - dedicated, require the data terminal ready signal (DTR) simpb - simple, no control signals required for data transmission and reception. By default output leads will be low. nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.2
cdx6500frdtepClockSourceint - internal clock source ext - external clock source extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.3
cdx6500frdtepClockSpeedThis is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependent on the card type,and on the interface type.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.4
cdx6500frdtepMaxStationsThis is the highest station number to be configured on this FRI port. It is used to limit the configuration of stations.rodeprecated
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.5
cdx6500frdtepFrameSeqCountingPort uses normal or extended frame sequence numbering: normal - normal sequencing (modulo 8) ext - extended sequencing (modulo 128) nc - Skipped during configuration. All stations on this port will be set to this value.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.6
cdx6500frdtepPktSeqCountingPort uses normal or extended packet level sequence numbers normal - normal sequencing (Modulo 8) ext - extended sequencing (Modulo 128) nc - Skipped during configuration. This parameter must be set to the same value at both this FRI port and the remote FRI port. All stations on this port will be set to this value.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.7
cdx6500frdtepCtrlProtocolWhether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled lmi - LMI is enabled. annexA - Annex A is enabled. auto - Auto-learn the Network control protocol type nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.8
cdx6500frdtepT391This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.9
cdx6500frdtepT392This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.10
cdx6500frdtepN391Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.12
cdx6500frdtepN392Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.13
cdx6500frdtepN393Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.14
cdx6500frdtepNT1This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.15
cdx6500frdtepNT2This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.16
cdx6500frdtepNN1Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.17
cdx6500frdtepNN2Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.18
cdx6500frdtepNN3Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.19
cdx6500frdtepHighPriorityStnThis parameter specifies a station who's PVC status has priority over all other stations when FRI same port back up is enabled. When the network reports this DLCI inactive, an alternate connection over a backup link is attempted.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.20
cdx6500frdtepMaxVoiceBWBitsPerSecThis parameter limits the bandwidth, in bits per sec (including overhead), for voice traffic passing through this frame relay port. A zero value disables any voice passing through this port.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.21
cdx6500frdtepSegSizeVoicePresentData packets to be segmented into this maximum frame size when voice is active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.22
cdx6500frdtepSegSizeVoiceNotPresentData packets to be segmented into this maximum frame size when voice is not active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments segSize2048 - 2048 byte segments segSize4096 - 4096 byte segments disable - segment size is 32768 bytes nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.23
cdx6500frdtepInvertTXClockThis parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.24
cdx6500frdtepControlProtocolOptionsThese options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async)rw
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.25
cdx6500frdtepDiscardControlOptionsThis parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE framesrw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.26
cdx6500frdtepElectricalInterfaceTypeSpecify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabledrw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.27
cdx6500frdtepV24ElectricalInterfaceOptionSpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signalrw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.28
cdx6500frdtepHighSpeedElectricalInterfaceOptionSpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cablerw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.5.1.29
cdx6500PCTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.3
cdx6500SPCTFRDTEStationTableAll of the configuration parameters relevant to the Frame Relay DTE Station table.
SEQUENCE OF Cdx6500SPCTFRDTEStationEntry
.1.3.6.1.4.1.449.2.1.2.1.3.2
cdx6500SPCTFRDTEStationEntryA row of Frame Realy DTE station configuration parameters.
Cdx6500SPCTFRDTEStationEntry
.1.3.6.1.4.1.449.2.1.2.1.3.2.1
cdx6500frdtesCfgPortNumFR DTE Port number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.1
cdx6500frdtesCfgDLCIThe Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRI Port. Its valid range is 16 - 1007. It must match the DLCI configured on the FR Networking Node.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.2
cdx6500frdtesStationTypeIdentifies the type of station being configured. annexG - This station uses X.25 signaling for layer 3 bypass - This station type bypasses layer 3. There is no signaling for SVC's on this station. voiceRelay - Not used in the current version.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.3
cdx6500frdtesCommInfoRateThis parameter (CIR) specifies the rate (in bits-per-second) that the Frame Relay network agrees to transfer information under congested conditions for the FRI Station. This value is used to throttle data on the FRI station for congestion control purposes. The CIR cannot be greater than the link speed.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.4
cdx6500frdtesCommBurstSizeThis parameter (BC) specifies the maximum amount of data (in bits) that the Frame Relay network agrees to transfer over a time interval T = Committed Burst Size / Committed Information Rate. Must be > 1/20th of the Committed Information Rate. This is used for congestion control purposes.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.5
cdx6500frdtesTransDelayThis parameter is the expected one-way delay through the network. This is specified in milliseconds.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.6
cdx6500frdtesControlledModeThis parameter controls the method of congestion control: normal - congestion control is normal disable - never enter Congested State (CTRL) congested - never enter a Non-Congested State (UCTRL) limit - congestion control is normal but limits the data rate to no lower than CIR. nc - Skipped during configurationrw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.7
cdx6500frdtesLinkAddressThe logical link address must be set to complementary values in this FRI station and its corresponding remote FRI station: dte - station to have logical DTE address (A) dce - station to have logical DCE address (B) nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.8
cdx6500frdtesPVCChannelsNumber of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.9
cdx6500frdtesStartingPVCThis is the starting logical channel number for the Permanent Virtual Circuits on this FRI station. Not used if the number of PVCs = 0.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.10
cdx6500frdtesSVCChannelsNumber of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.11
cdx6500frdtesStartingSVCThis is the starting logical channel number for the Switched Virtual Circuits on this station (logical link). Not used if the number of SVCs = 0.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.12
cdx6500frdtesInitialFrameSpecify the initial frame required by other end for (logical) link startup: none - do nothing (other end initiates link-up) sabm - send SABM disc - send DISC, then SABM nc - Skipped during configurationrw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.13
cdx6500frdtesRetryTimerT1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds).rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.14
cdx6500frdtesPollTimerThis sets the time an idle link is probed for assurance of connection to the remote FRI station. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.15
cdx6500frdtesTriesThe maximum number of attempts allowed to complete a transmission.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.16
cdx6500frdtesFrameWinSizeFrame level window size must be set to the same value at both this FRI station and the remote FRI station.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.17
cdx6500frdtesPacketWinSizePacket level window size must be set to the same value at both this FRI station and the remote FRI station.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.18
cdx6500frdtesMaxPacketSizeThis is the maximum X.25 packet size used on the station (logical link). For proper operation, this must be set to the same value at both this FRI station and the remote FRI station. nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.19
cdx6500frdtesUpperQueueThis is the maximum number of data packets a channel on this station (logical link) will queue for transmission before invoking flow control to the attached channelrw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.20
cdx6500frdtesLowerQueueThis is the number of data packets a channel on this FRI station will have queued for transmission when it releases flow control to the attached channelrw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.21
cdx6500frdtesRestartTimerRestart-Request timeout timer in seconds. If timer expires on this FRI station, the Restart request is sent again.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.22
cdx6500frdtesResetTimerReset-Request timeout timer in seconds. If timer expires on this FRI station, the Reset request is sent again.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.23
cdx6500frdtesCallTimerCall-Request timeout timer in seconds. If timer expires on this FRI station, the call is cleared.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.24
cdx6500frdtesClearTimerClear-Request timeout timer in seconds. If timer expires on this FRI station, the Clear request is sent again.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.25
cdx6500frdtesX25OptionsSelect X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: Please use cdx6500frdtesStnX25Options, which has been added to replace this object.rodeprecated
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.26
cdx6500frdtesRCDestinationAll calls entering this station will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route all calls to X.25 port 3, use X25-3. To route calls to FRI port 2, station 4, use FRI-2S4. Blank this field to disable this function.rw
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.27
cdx6500frdtesCUGThe station may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number and separated by a comma. (e.g. 12,34,56,09,02,03 ). Two hyphens following each oher indicates no CUG Membership 00-99 - CUG Membershiprw
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.28
cdx6500frdtesBillingRecordsThis controls whether billing (accounting) records will be created for calls on this FRI station. off - Billing records will not be created. on - Billing records will be created. nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.29
cdx6500frdtesCfgStationNumThe number of the logical link on the line. This is the value of Sxx for routing purposes.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.30
cdx6500frdtesStnX25OptionsSelect X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: This object has been added to replace cdx6500frdtesX25Options.rw
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.31
cdx6500frdtesStnFrameSegmenterDetermine if this station will support the Frame Segmenter Header.The Frame Segmenter should be enabled if the frame relay port is configured to pass voice traffic. disabled - Frame Segmenter disabled. enabled - Frame Segmenter enabled. nc - Skipped during configuration.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.32
cdx6500frdtesStnVoiceSVCChannelsNumber of logical voice channels used in Switched Virtual Circuits.The total number of voice and data channels on a station (logical link) should be kept as small as possible and consistent with needs.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.33
cdx6500frdtesStnVoiceCongCtrlModeThis parameter controls the method of voice congestion control: enabled - Station is forced into congestion when voice calls are detected. disabled - Station operates normally Use this parameter in voice applications, when the frame relay network can have more than 140ms of data buffered. One typical application is asymmetrical speeds. When this parameter is enabled, and voice is detected, delta T is forced to 50 ms and the BC is forced to 1/20 CIR.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.34
cdx6500frdtesStnPeakUtilizationThe monitoring interval size specifies the time period to use when monitoring peak data link/CIR (Committed Information Rate) utilization. 0 - Disables this monitoring feature. 1 to 240 - The number of 64 second increments to use for the monitoring interval time period. For example: a value of 30 specifies a time duration equal to 30 * 64 seconds = 1920 seconds or 32 minutes.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.35
cdx6500frdtesStnMaxInboundQueueThis specifies the maximum number of frames from the network which may be queued in a BYPASS station. A smaller value may ve choosen for applications which experience objectable delays, if due to excessive growth of the BYPASS inbound queue.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.36
cdx6500frdtesStnAnnexGRateReductionThis parameter determines whether Annex G stations will invoke implicit congestion control when a link error is detected, reducing their transmitted information rate to 1/4 CIR. The rate will be gradually increased in the normal way as non-BECN frames are received.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.2.1.37
cdx6500Statistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3
cdx6500StatProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1
cdx6500PSTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.1
cdx6500PPSTFRDTEPortTableAll of the statistics parameters relevant to the Frame Relay DTE Port table.
SEQUENCE OF Cdx6500PPSTFRDTEPortEntry
.1.3.6.1.4.1.449.2.1.3.1.1.5
cdx6500PPSTFRDTEPortEntryA row of Frame Relay DTE Port statistics parameters.
Cdx6500PPSTFRDTEPortEntry
.1.3.6.1.4.1.449.2.1.3.1.1.5.1
cdx6500frdtepStatsPortNumSpecifies a specific port in the network diagram.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.1
cdx6500frdtepPortStatusSpecifies the current port status. disabled - Port has been disabled. enabled - Port is operational. busyOut - Port has been busied out. up - Port is operational. down - Port is down. na - Value not Available.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.2
cdx6500frdtepPortSpeedMessage transmition speed in bps.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.3
cdx6500frdtepUtilizationInFactor determined by comparison of volume (characters per second) of data and clock rate for a specific port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.4
cdx6500frdtepUtilizationOutFactor determined by comparison of volume (characters per second) of data and clock rate for a specific port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.5
cdx6500frdtepCharInTotalNumber of characters received since last boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.6
cdx6500frdtepCharOutTotalNumber of characters transmitted since last boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.7
cdx6500frdtepCharsInPerSecAverage number of characters received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.8
cdx6500frdtepCharsOutPerSecAverage number of characters transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.9
cdx6500frdtepFrameInTotalNumber of frames received since last boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.10
cdx6500frdtepFrameOutTotalNumber of frames transmitted since last boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.11
cdx6500frdtepFramesInPerSecAverage number of frames received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.12
cdx6500frdtepFramesOutPerSecAverage number of frames transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.13
cdx6500frdtepOverrunErrorsAn input buffer overflowed and characters were discarded.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.14
cdx6500frdtepUnderrunErrorsNumber of errors detected since last node boot or reset of statistics.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.15
cdx6500frdtepCRCErrorsNumber of errors detected by Cyclic Redundancy Check since last node boot reset of statistics.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.5.1.16
cdx6500PSTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.3
cdx6500SPSTFRDTEStationTableAll of the statistics parameters relevant to the Frame Relay DTE Station (DLCI) table.
SEQUENCE OF Cdx6500SPSTFRDTEStationEntry
.1.3.6.1.4.1.449.2.1.3.1.3.2
cdx6500SPSTFRDTEStationEntryA row of Frame Relay DTE station (DLCI) Statistics parameters.
Cdx6500SPSTFRDTEStationEntry
.1.3.6.1.4.1.449.2.1.3.1.3.2.1
cdx6500frdtesStatsPortNumSpecifies a specific port in the network diagram.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.1
cdx6500frdtesStatsDLCIData Link Connection Identifier is the unique identifier for the station on the FRI port and must match the DLCI configured on the Frame Relay networking node.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.2
cdx6500frdtesUtilizationInIndicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.3
cdx6500frdtesUtilizationOutIndicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.4
cdx6500frdtesMaxSVCCountMaximum number of SVCs available in the network.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.5
cdx6500frdtesCurrentSVCCountCurrent number of SVCs currently in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.6
cdx6500frdtesCharInTotalNumber of characters received since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.7
cdx6500frdtesCharOutTotalNumber of characters transmitted since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.8
cdx6500frdtesCharsInPerSecAverage number of characters received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.9
cdx6500frdtesCharsOutPerSecAverage number of characters transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.10
cdx6500frdtesPktInTotalNumber of packets received since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.11
cdx6500frdtesPktOutTotalNumber of packets transmitted since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.12
cdx6500frdtesPktsInPerSecAverage number of packets received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.13
cdx6500frdtesPktsOutPerSecAverage number of packets transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.14
cdx6500frdtesPacketsQueuedCurrent number of packets buffered since last node boot or statistics reset.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.15
cdx6500frdtesFrameInTotalNumber of frames received since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.16
cdx6500frdtesFrameOutTotalNumber of frames transmitted since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.17
cdx6500frdtesFramesInPerSecAverage number of frames received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.18
cdx6500frdtesFramesOutPerSecAverage number of frames transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.19
cdx6500frdtesInfoFramesInData received since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.20
cdx6500frdtesInfoFramesOutData transmitted since last node boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.21
cdx6500frdtesRNRFramesInUsed by the DTE or the network to request that the data flow be stopped on a particular virtual circuit.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.22
cdx6500frdtesRNRFramesOutUsed by the DTE or the network to request that the data flow be stopped on a particular virtual circuit.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.23
cdx6500frdtesRRFramesInUsed to clear the RNR request.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.24
cdx6500frdtesRRFramesOutUsed to clear the RNR request.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.25
cdx6500frdtesREJFramesInA REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.26
cdx6500frdtesREJFramesOutA REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.27
cdx6500frdtesDataPktsInA packet containing user information.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.28
cdx6500frdtesDataPktsOutA packet containing user information.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.29
cdx6500frdtesResetStatsResets the specified Frame Relay station statistics. reset - Reset station statistics. noReset - Do not reset station statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.30
cdx6500frdtesBootBoots the specified Frame Relay station. boot - Boot station. noBoot - Do not boot station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.31
cdx6500frdtesDisableDisables the specified Frame Relay station. disable - Disable station. noDisable - Do not disable station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.32
cdx6500frdtesEnableEnables the specified Frame Relay station. enable - Enable station. noEnable - Do not enable station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.33
cdx6500frdtesStatsStationNumberThe number of the FRI Station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.2.1.34
cdx6500Controls
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4