Home/Catalog/FRDCE-OPT-MIB

FRDCE-OPT-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

114
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

114 total
Object Name
codex
OBJECT IDENTIFIER
.1.3.6.1.4.1.449
RFC1155-SMI
Unknown
.1.3.6.1.4.1.449
cdxProductSpecific
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2
cdx6500
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1
cdx6500Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2
cdx6500CfgProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1
cdx6500PCTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.1
cdx6500PCTFRDCEPortTableAll of the configuration parameters relevant to the Frame Relay DCE Port table.
SEQUENCE OF Cdx6500PCTFRDCEPortEntry
.1.3.6.1.4.1.449.2.1.2.1.1.6
cdx6500PCTFRDCEPortEntryA row of SDLC Port configuration parameters.
Cdx6500PCTFRDCEPortEntry
.1.3.6.1.4.1.449.2.1.2.1.1.6.1
cdx6500frdcepCfgPortNumPort Number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.1
cdx6500frdcepConnectionTypeSpecify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. newvalSimp - same functionality as 'simp', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.2
cdx6500frdcepClockSourceint - internal clock source. ext - external clock source. extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.3
cdx6500frdcepClockSpeedThis is the speed of the port in bits per second, when using internal clocking. Note that the maximum port speed is dependent on the type of hardware installed. Consult the users manual for details.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.4
cdx6500frdcepMaxStationsThe highest station number to be configured on this FRA port. It is used to limit the configuration of stations.rodeprecated
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.5
cdx6500frdcepCtrlProtocolWhether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled. lmi - LMI is enabled. annexA - Annex A is enabled. newvalAnnexD - same functionality as 'annexD', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.6
cdx6500frdcepT391This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.7
cdx6500frdcepT392This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.8
cdx6500frdcepN391This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.9
cdx6500frdcepN392This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.10
cdx6500frdcepN393This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.11
cdx6500frdcepNT1This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.12
cdx6500frdcepNT2This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.13
cdx6500frdcepNN1This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.14
cdx6500frdcepNN2This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.15
cdx6500frdcepNN3This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.16
cdx6500frdcepSubaddressCalls addressed to this node and with this subaddress will be routed to this port.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.17
cdx6500frdcepBiDirAnnexDWhether ANSI T1.617 Annex D bi-directional procedures are enabled bi - Bi-directional procedures are enabled. uni - Uni-directional procedures are enabled. newvalBi - same functionality as 'bi', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.18
cdx6500frdcepInvertTXClockThis parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.19
cdx6500frdcepControlProtocolOptionsThese options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async)ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.20
cdx6500frdcepDiscardControlOptionsThis parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE framesro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.21
cdx6500frdcepElectricalInterfaceTypeSpecify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabledro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.22
cdx6500frdcepV24ElectricalInterfaceOptionSpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signalro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.23
cdx6500frdcepHighSpeedElectricalInterfaceOptionSpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cablero
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.6.1.24
cdx6500PCTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.3
cdx6500SPCTFRDCEStationTableAll of the configuration parameters relevant to the Frame Relay DCE Station table.
SEQUENCE OF Cdx6500SPCTFRDCEStationEntry
.1.3.6.1.4.1.449.2.1.2.1.3.3
cdx6500SPCTFRDCEStationEntryA row of Frame Relay DCE station configuration parameters.
Cdx6500SPCTFRDCEStationEntry
.1.3.6.1.4.1.449.2.1.2.1.3.3.1
cdx6500frdcesCfgPortNumStation number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.1
cdx6500frdcesCfgDLCIThe Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port. Its valid range is 16 - 1007. It must match the DLCI configured on the attached FRAD.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.2
cdx6500frdcesAutocallMnemThis is the mnemonic name used for auto calling. A blank indicates auto calling is disabled.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.3
cdx6500frdcesAutocallTimeoutThis is the time interval in seconds between call attempts when auto calling.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.4
cdx6500frdcesMaxAutocallsThis parameter is used to specify the number of times that this FRA station will attempt to call when auto calling is enabled. A value of zero will allow unlimited attempts.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.5
cdx6500frdcesRemoteConnIDThis parameter specifies the number of the remote LAN Connection or the number of the remote FRA station that this FRA station will attempt to connect to if configured for autocall.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.6
cdx6500frdcesPriorityThis parameter specifies the Traffic Priority of this FRA station. newvalLow - same functionality as 'low', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.7
cdx6500frdcesBillingRecordsThis controls whether billing (accounting) records will be created for calls on this FRA station. newvalDisabled : same functionality as 'disabled', new enumeration added for RFC1155 compliance.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.8
cdx6500frdcesStationNumThe number of the logical link on the line. This is the value of Sxx for routing purposes.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.9
cdx6500frdcesMaxInboundQueueThis specifies the maximum number of frames which may be queued in the station's inbound queue. A smaller value may be choosen for applications which experience objectionable delays, if due to excessive growth of the station's inbound queue.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.3.3.1.10
cdx6500Statistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3
cdx6500StatProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1
cdx6500PSTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.1
cdx6500PPSTFRDCEPortTableAll of the statistics parameters relevant to the Frame Relay DCE Port table.
SEQUENCE OF Cdx6500PPSTFRDCEPortEntry
.1.3.6.1.4.1.449.2.1.3.1.1.6
cdx6500PPSTFRDCEPortEntryA row of Frame Relay DCE Port statistics parameters.
Cdx6500PPSTFRDCEPortEntry
.1.3.6.1.4.1.449.2.1.3.1.1.6.1
cdx6500frdcepStatsPortNumPort Number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.1
cdx6500frdcepPortStatusPort Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running. down - Port is down. disabled - Port has been disabled. enabled - port has been enabled, but is not yet Up. busyOut - port has been set to be disabled as soon as last active call is disestablished. No new calls will be established. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.2
cdx6500frdcepPortSpeedThis is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking is not being received from attatched device.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.3
cdx6500frdcepUtilizationInPertcentage of Port input bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.4
cdx6500frdcepUtilizationOutPertcentage of Port output bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.5
cdx6500frdcepCharInTotalNumber of message received since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.6
cdx6500frdcepCharOutTotalNumber of message sent since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.7
cdx6500frdcepCharsInPerSecNumber of characters received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.8
cdx6500frdcepCharsOutPerSecNumber of characters received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.9
cdx6500frdcepFrameInTotalNumber of frames received since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.10
cdx6500frdcepFrameOutTotalNumber of frames sent since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.11
cdx6500frdcepFramesInPerSecAverage number of frames received per second during the previous minutero
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.12
cdx6500frdcepFramesOutPerSecAverage number of frames transmitted per second during the previous minutero
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.13
cdx6500frdcepOverrunErrorsTotal number of overrun errors counted by the I/O driver.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.14
cdx6500frdcepUnderrunErrorsTotal number of underrun errors counted by the I/O driver.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.15
cdx6500frdcepCRCErrorsTotal number of CRC errors counted by the I/O driver.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.6.1.16
cdx6500PSTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.3
cdx6500SPSTFRDCEStationTableAll of the statistics parameters relevant to the Frame Relay DCE Station (DLCI) table.
SEQUENCE OF Cdx6500SPSTFRDCEStationEntry
.1.3.6.1.4.1.449.2.1.3.1.3.3
cdx6500SPSTFRDCEStationEntryA row of Frame Relay DCE station (DLCI) Statistics parameters.
Cdx6500SPSTFRDCEStationEntry
.1.3.6.1.4.1.449.2.1.3.1.3.3.1
cdx6500frdcesStatsPortNumPort Number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.1
cdx6500frdcesStatsDLCIThe Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.2
cdx6500frdcesUtilizationInThe quantity of user bytes received on the line as a percentage of the maximum number of bytes that could have been received.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.3
cdx6500frdcesUtilizationOutThe quantity of user bytes sent on the line as a percentage of the maximum number of bytes that could have been received.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.4
cdx6500frdcesMaxSVCCountMaximum number of SVCs available in the network.rodeprecated
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.5
cdx6500frdcesCurrentSVCCountNumber of SVCs currently in use.rodeprecated
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.6
cdx6500frdcesCharInTotalTotal number of characters received since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.7
cdx6500frdcesCharOutTotalTotal number of characters sent since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.8
cdx6500frdcesCharsInPerSecAverage number of characters received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.9
cdx6500frdcesCharsOutPerSecAverage number of characters transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.10
cdx6500frdcesPktInTotalTotal number of Packets received since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.11
cdx6500frdcesPktOutTotalTotal number of Packets sent since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.12
cdx6500frdcesPktsInPerSecAverage number of Packets received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.13
cdx6500frdcesPktsOutPerSecAverage number of Packets transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.14
cdx6500frdcesPacketsQueuedCurrent number of packets buffered since since last node, port, or station boot or statistics reset.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.15
cdx6500frdcesFrameInTotalTotal number of frames received since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.16
cdx6500frdcesFrameOutTotalTotal number of frames sent since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.17
cdx6500frdcesFramesInPerSecAverage number of frames received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.18
cdx6500frdcesFramesOutPerSecAverage number of frames transmitted per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.19
cdx6500frdcesInfoFramesInNumber of data frames received since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.20
cdx6500frdcesInfoFramesOutNumber of data frames sent since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.21
cdx6500frdcesRNRFramesInNumber of RNR frames received since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.22
cdx6500frdcesRNRFramesOutNumber of RNR frames sent since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.23
cdx6500frdcesRRFramesInNumber of RR frames received since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.24
cdx6500frdcesRRFramesOutNumber of RR frames sent since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.25
cdx6500frdcesREJFramesInNumber of REJ frames received since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.26
cdx6500frdcesREJFramesOutNumber of REJ frames sent since last node, port, or station boot or statistics reset.rodeprecated
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.27
cdx6500frdcesDataPktsInNumber of data packets received since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.28
cdx6500frdcesDataPktsOutNumber of data packets sent since last node, port, or station boot or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.29
cdx6500frdcesResetStatsreset : Resets the specified Frame Relay station statistics. noReset : Do not reset the specified Frame Relay station statistics.rwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.30
cdx6500frdcesBootboot : Boots the specified Frame Relay station. noBoot : Do not boot the specified Frame Relay station.rwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.31
cdx6500frdcesDisabledisable : Disables the specified Frame Relay station. noDisable : Do not disable the specified Frame Relay station.rwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.32
cdx6500frdcesEnableenable : Enable the specified Frame Relay station. noEnable : Do not enable the specified Frame Relay station.rwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.3.1.33
cdx6500Controls
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4
cdx6500ContFRATable
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4.17
cdx6500frdcepPContTableControl parameters for FRA ports.
SEQUENCE OF Cdx6500frdcepPContEntry
.1.3.6.1.4.1.449.2.1.4.17.1
cdx6500frdcepPContEntryA row of FRA port control.
Cdx6500frdcepPContEntry
.1.3.6.1.4.1.449.2.1.4.17.1.1
cdx6500frdcepContPortNumberPort number of the FRA port.
INTEGER
.1.3.6.1.4.1.449.2.1.4.17.1.1.1
cdx6500frdcepContPortControlControl operations for the specified FRA port. boot - Boots the FRA port enable - Enables the FRA port disable - Disables the FRA port resetstats - Resets the FRA port statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.17.1.1.2
cdx6500frdcesSContTableControl parameter for Fra stations
SEQUENCE OF Cdx6500frdcesSContEntry
.1.3.6.1.4.1.449.2.1.4.17.2
cdx6500frdcesSContEntryA row of FRA Station control
Cdx6500frdcesSContEntry
.1.3.6.1.4.1.449.2.1.4.17.2.1
cdx6500frdcesStationPortNumberFra Station Port number
INTEGER
.1.3.6.1.4.1.449.2.1.4.17.2.1.1
cdx6500frdcesStationDLCIFra Station DLCI number
INTEGER
.1.3.6.1.4.1.449.2.1.4.17.2.1.2
cdx6500frdcesStationControlControl operations for the specified FRA station. boot - Boot the FRA station enable - Enables the FRA station disable - Disables the FRA station resetstats - Resets the FRA station statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.17.2.1.3
FRDCE-OPT-MIB - SNMP MIB Reference | MIBs Explorer