The MIB module to allow insertion of selected circuit into the ifTable.
Main OID:
frciMIB.1.3.6.1.2.1.1
20
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

20 total
Object Name
frciMIBThe MIB module to allow insertion of selected circuit into the ifTable.
MODULE-IDENTITY
.1.3.6.1.2.1.1
frciObjects
OBJECT IDENTIFIER
.1.3.6.1.2.1.1.1
frciCircuitTableThe Frame Relay Circuit Interface Circuit Table.
SEQUENCE OF FrciCircuitEntry
.1.3.6.1.2.1.1.1.1
frciCircuitEntryAn entry in the Frame Relay Circuit Interface Circuit Table.
FrciCircuitEntry
.1.3.6.1.2.1.1.1.1.1
frciCircuitObjectThis value contains the object identifier that uniquely describes the circuit that is to be added to this table. The object identifier should be that of the first field on the table that contains the circuit. The index sub identifiers should uniquely define the circuit. The purpose of this object identifier is to point a network manager to the table in which the circuit was created as well as define the circuit on which the interface is defined. Valid tables for this object are the frCircuitTable from the Frame Relay DTE MIB(FRAME-RELAY-DTE-MIB) or the frPVCEndptTable from the Frame Relay Service MIB (FRNETSERV-MIB). However, it does not exclude enterprise MIBs used for the same purpose.
OBJECT IDENTIFIER
.1.3.6.1.2.1.1.1.1.1.1
frciCircuitFlowThe direction of data flow through the circuit for which the virtual interface is defined. The following define the information that the virtual interface will report. transmit(1) - Only transmitted frames receive(2) - Only received frames both(3) - Both transmitted and received frames. The need to monitor directional flow depends on the application for which the circuit is created. For example, Monitoring of protocols passed on a circuit using RMON-II (RFC 2021) does not capture the direction the flow. This is left to the circuit.
FrciFlowDir
.1.3.6.1.2.1.1.1.1.1.2
frciCircuitStatusThe status of the current row. This object is used to add, delete, and disable rows in this table. When the status changes to active(1), a row will also be added to the interface map table below and a row will be added to the ifTable. These rows SHOULD not be removed until the status is changed from active(1). The value of ifIndex for the row that is added to the ifTable is determined by the agent and MUST follow the rules of the ifTable. The value of ifType for that interface will be <?need ifType?>. When this object is set to destroy(6), the associated row in the interface map table will be removed and the ifIndex will be removed from the ifTable. Removing the ifIndex MAY initiate a chain of events that causes changes to other tables as well. The rows added to this table MUST have a valid object identifier for frciCircuitObject. This means that the referenced object must exist and it must be in a table that supports circuits. The object referenced by frciCircuitObject MUST exist prior to transitioning a row to active(1). If at any point the object referenced by frciCircuitObject does not exist or the row containing it is not in the active(1) state, the status SHOULD report notReady(3). The effects transitioning from active(1) to notReady(3) are the same as those caused by setting the status to destroy(6).rw
RowStatus (SNMPv2-TC)
.1.3.6.1.2.1.1.1.1.1.3
frciCircuitIfIndexThe ifIndex that the agent assigns to this row.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.2.1.1.1.1.1.4
frciCircuitCreateTimeThis object returns the value of sysUpTime at the time the value of frciCircuitStatus last transitioned to active(1). If frciCircuitStatus has never been active(1), this object SHOULD return 0.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.2.1.1.1.1.1.5
frciIfMapTableThe Frame Relay Circuit Interface Map Table.
SEQUENCE OF FrciIfMapEntry
.1.3.6.1.2.1.1.1.2
frciIfMapEntryAn entry in the Frame Relay Circuit Interface Map Table.
FrciIfMapEntry
.1.3.6.1.2.1.1.1.2.1
frciIfMapObjectThis value contains the value of frciCircuitObject that corresponds to the current ifIndex.ro
OBJECT IDENTIFIER
.1.3.6.1.2.1.1.1.2.1.1
frciIfMapFlowThe value contains the value of frciCircuitFlow that corresponds to the current ifIndex.ro
FrciFlowDir
.1.3.6.1.2.1.1.1.2.1.2
frciCapabilities
OBJECT IDENTIFIER
.1.3.6.1.2.1.1.2
frciConformance
OBJECT IDENTIFIER
.1.3.6.1.2.1.1.3
frciMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.2.1.1.3.1
frciCircuitGroupA collection of required objects providing information from the circuit table.
Unknown
.1.3.6.1.2.1.1.3.1.1
frciIfMapGroupA collection of required objects providing information from the interface map table.
Unknown
.1.3.6.1.2.1.1.3.1.2
frciMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.2.1.1.3.2
frciComplianceThe compliance statement for SNMPv2 entities which support with Frame Relay Circuit Interfaces. This group defines the minimum level of support required for compliance.
Unknown
.1.3.6.1.2.1.1.3.2.1