FJDARY-E50
AI MIB Summary
Standard SNMP MIB module defining data structures for FJDARY-E50.
535
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
535 total| Object Name |
|---|
fujitsu OBJECT IDENTIFIER .1.3.6.1.4.1.211 |
RFC1213-MIB Unknown .1.3.6.1.4.1.211 |
product OBJECT IDENTIFIER .1.3.6.1.4.1.211.1 |
storage OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21 |
nsp OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1 |
fjdarye50 OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50 |
fjdarySsp OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.1 |
fjdarySspMachineIdThis value indicates the identification number of this system.
ttssssssssssssmmmmmmmmmmmmccssssssssssss
| | | | |
| | | | +-serial number(12byte)
| | | +-check code(2byte)
| | +-model name(12byte)
| +-series name(12byte)
+-type code(2byte)ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.1.1 |
fjdarySspConfigDateThe last date when the configuration was applied.
yyyymmddHHMMSS
| | | | | |
| | | | | +-second
| | | | +-minute
| | | +-hour
| | +-day
| +-month
+-yearro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.211.1.21.1.50.1.2 |
fjdarySspWwnnThe value of this object indecates the World Wide Node Name.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.1.3 |
fjdarySspVenderIdThe value of this object indecates the Vender ID.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.1.4 |
fjdarySspProductIdThe value of this object indecates the Product ID.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.1.5 |
fjdarySspBoxIdThis value of a meaning within a user system. An initial value is the
same as fjdarySspMachineId.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.1.6 |
fjdarySspMaintenanceServiceLevelThe value of this object indecates the support level of maintenance
service. Level2 supports interface that strengthens the security
level from level1.ro Enumeration .1.3.6.1.4.1.211.1.21.1.50.1.7 |
fjdaryPconfig OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2 |
fjdaryCm OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.1 |
fjdaryCmCountThe number of CM(controller module)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.1.1 |
fjdaryCmTable SEQUENCE OF FjdaryCmEntry .1.3.6.1.4.1.211.1.21.1.50.2.1.2 |
fjdaryCmEntry FjdaryCmEntry .1.3.6.1.4.1.211.1.21.1.50.2.1.2.1 |
fjdaryCmIndexThe value of this object uniquely identifies this fjdaryCm entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.1.2.1.1 |
fjdaryCmItemIdThe value of this object indicates the identification number of this
CM.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.1.2.1.2 |
fjdaryCmStatusThe value of this object indicates the state of this CM.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.1.2.1.3 |
fjdaryCmModuleIdThe value of this object indicates the module indicates of this CM.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.1.2.1.4 |
fjdaryCmRoleThe value of this object indicates the role of this CM.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.1.2.1.5 |
fjdaryCmPtIdThe value of this object indicates the PT management informatiom of
this CM.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.1.2.1.6 |
fjdaryCa OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.2 |
fjdaryCaCountThe number of CA(channel adapter)'s informations (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.2.1 |
fjdaryCaTable SEQUENCE OF FjdaryCaEntry .1.3.6.1.4.1.211.1.21.1.50.2.2.2 |
fjdaryCaEntry FjdaryCaEntry .1.3.6.1.4.1.211.1.21.1.50.2.2.2.1 |
fjdaryCaIndexThe value of this object uniquely identifies this fjdaryCa entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.2.2.1.1 |
fjdaryCaItemIdThe value of this object indicates the identification number of this
CA.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.2.2.1.2 |
fjdaryCaStatusThe value of this object indicates the state of this CA.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.2.2.1.3 |
fjdaryCaModuleIdThe value of this object indicates the module indicates of this CA.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.2.2.1.4 |
fjdaryCaTypeThe value of this object indicates the type of this CA.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.2.2.1.5 |
fjdaryCaPtIdThe value of this object indicates the PT management informatiom of
this CA.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.2.2.1.6 |
fjdaryFrt OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.3 |
fjdaryFrtCountThe number of FRT(front-end router)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.3.1 |
fjdaryFrtTable SEQUENCE OF FjdaryFrtEntry .1.3.6.1.4.1.211.1.21.1.50.2.3.2 |
fjdaryFrtEntry FjdaryFrtEntry .1.3.6.1.4.1.211.1.21.1.50.2.3.2.1 |
fjdaryFrtIndexThe value of this object uniquely identifies this fjdaryFrt entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.3.2.1.1 |
fjdaryFrtItemIdThe value of this object indicates the identification number of this
FRT.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.3.2.1.2 |
fjdaryFrtStatusThe value of this object indicates the state of this FRT.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.3.2.1.3 |
fjdaryBrt OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.4 |
fjdaryBrtCountThe number of BRT(back-end router)'s informations (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.4.1 |
fjdaryBrtTable SEQUENCE OF FjdaryBrtEntry .1.3.6.1.4.1.211.1.21.1.50.2.4.2 |
fjdaryBrtEntry FjdaryBrtEntry .1.3.6.1.4.1.211.1.21.1.50.2.4.2.1 |
fjdaryBrtIndexThe value of this object uniquely identifies this fjdaryBrt entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.4.2.1.1 |
fjdaryBrtItemIdThe value of this object indicates the identification number of this
BRT.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.4.2.1.2 |
fjdaryBrtStatusThe value of this object indicates the state of this BRT.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.4.2.1.3 |
fjdaryCmmemory OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.5 |
fjdaryCmmemoryCountThe number of CM memory's informations (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.5.1 |
fjdaryCmmemoryTable SEQUENCE OF FjdaryCmmemoryEntry .1.3.6.1.4.1.211.1.21.1.50.2.5.2 |
fjdaryCmmemoryEntry FjdaryCmmemoryEntry .1.3.6.1.4.1.211.1.21.1.50.2.5.2.1 |
fjdaryCmmemoryIndexThe value of this object uniquely identifies this fjdaryCmmemory
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.5.2.1.1 |
fjdaryCmmemoryItemIdThe value of this object indicates the identification number of this
CM memory.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.5.2.1.2 |
fjdaryCmmemoryStatusThe value of this object indicates the state of this CM memory.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.5.2.1.3 |
fjdaryCmmemoryCapacityThe value of this object indicates the capacity of this CM memory.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.5.2.1.4 |
fjdaryCmfan OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.6 |
fjdaryCmfanCountThe number of CM FAN's informations (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.6.1 |
fjdaryCmfanTable SEQUENCE OF FjdaryCmfanEntry .1.3.6.1.4.1.211.1.21.1.50.2.6.2 |
fjdaryCmfanEntry FjdaryCmfanEntry .1.3.6.1.4.1.211.1.21.1.50.2.6.2.1 |
fjdaryCmfanIndexThe value of this object uniquely identifies this fjdaryCmfan entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.6.2.1.1 |
fjdaryCmfanItemIdThe value of this object indicates the identification number of this
CM FAN.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.6.2.1.2 |
fjdaryCmfanStatusThe value of this object indicates the state of this CM FAN.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.6.2.1.3 |
fjdaryCf OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.7 |
fjdaryCfCountThe number of CF(compact flash)'s informations (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.7.1 |
fjdaryCfTable SEQUENCE OF FjdaryCfEntry .1.3.6.1.4.1.211.1.21.1.50.2.7.2 |
fjdaryCfEntry FjdaryCfEntry .1.3.6.1.4.1.211.1.21.1.50.2.7.2.1 |
fjdaryCfIndexThe value of this object uniquely identifies this fjdaryCf entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.7.2.1.1 |
fjdaryCfItemIdThe value of this object indicates the identification number of this
CF.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.7.2.1.2 |
fjdaryCfStatusThe value of this object indicates the state of this CF.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.7.2.1.3 |
fjdaryOpnl OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.8 |
fjdaryOpnlCountThe number of OPNL(operation panel)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.8.1 |
fjdaryOpnlTable SEQUENCE OF FjdaryOpnlEntry .1.3.6.1.4.1.211.1.21.1.50.2.8.2 |
fjdaryOpnlEntry FjdaryOpnlEntry .1.3.6.1.4.1.211.1.21.1.50.2.8.2.1 |
fjdaryOpnlIndexThe value of this object uniquely identifies this fjdaryOpnl entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.8.2.1.1 |
fjdaryOpnlItemIdThe value of this object indicates the identification number of this
OPNL.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.8.2.1.2 |
fjdaryOpnlStatusThe value of this object indicates the state of this OPNL.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.8.2.1.3 |
fjdaryCefan OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.9 |
fjdaryCefanCountThe number of CE FAN's informations (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.9.1 |
fjdaryCefanTable SEQUENCE OF FjdaryCefanEntry .1.3.6.1.4.1.211.1.21.1.50.2.9.2 |
fjdaryCefanEntry FjdaryCefanEntry .1.3.6.1.4.1.211.1.21.1.50.2.9.2.1 |
fjdaryCefanIndexThe value of this object uniquely identifies this fjdaryCefan entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.9.2.1.1 |
fjdaryCefanItemIdThe value of this object indicates the identification number of this
CE FAN.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.9.2.1.2 |
fjdaryCefanStatusThe value of this object indicates the state of this CE FAN.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.9.2.1.3 |
fjdarySvc OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.10 |
fjdarySvcCountThe number of SVC(service controller)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.10.1 |
fjdarySvcTable SEQUENCE OF FjdarySvcEntry .1.3.6.1.4.1.211.1.21.1.50.2.10.2 |
fjdarySvcEntry FjdarySvcEntry .1.3.6.1.4.1.211.1.21.1.50.2.10.2.1 |
fjdarySvcIndexThe value of this object uniquely identifies this fjdarySvc entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.10.2.1.1 |
fjdarySvcItemIdThe value of this object indicates the identification number of this
SVC.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.10.2.1.2 |
fjdarySvcStatusThe value of this object indicates the state of this SVC.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.10.2.1.3 |
fjdarySvcFirmInfoThe value of this object indicates the firmware information of this
SVC.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.10.2.1.4 |
fjdarySmc OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.11 |
fjdarySmcCountThe number of SMC(system management controller)'s informations
(regardless of their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.11.1 |
fjdarySmcTable SEQUENCE OF FjdarySmcEntry .1.3.6.1.4.1.211.1.21.1.50.2.11.2 |
fjdarySmcEntry FjdarySmcEntry .1.3.6.1.4.1.211.1.21.1.50.2.11.2.1 |
fjdarySmcIndexThe value of this object uniquely identifies this fjdarySmc entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.11.2.1.1 |
fjdarySmcItemIdThe value of this object indicates the identification number of this
SMC.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.11.2.1.2 |
fjdarySmcStatusThe value of this object indicates the state of this SMC.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.11.2.1.3 |
fjdarySmcFirmInfoThe value of this object indicates the firmware information of this
SMC.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.11.2.1.4 |
fjdaryBcu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.12 |
fjdaryBcuCountThe number of BCU(battery control unit)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.12.1 |
fjdaryBcuTable SEQUENCE OF FjdaryBcuEntry .1.3.6.1.4.1.211.1.21.1.50.2.12.2 |
fjdaryBcuEntry FjdaryBcuEntry .1.3.6.1.4.1.211.1.21.1.50.2.12.2.1 |
fjdaryBcuIndexThe value of this object uniquely identifies this fjdaryBcu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.12.2.1.1 |
fjdaryBcuItemIdThe value of this object indicates the identification number of this
BCU.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.12.2.1.2 |
fjdaryBcuStatusThe value of this object indicates the state of this BCU.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.12.2.1.3 |
fjdaryBtu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.13 |
fjdaryBtuCountThe number of BTU(battery unit)'s informations (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.13.1 |
fjdaryBtuTable SEQUENCE OF FjdaryBtuEntry .1.3.6.1.4.1.211.1.21.1.50.2.13.2 |
fjdaryBtuEntry FjdaryBtuEntry .1.3.6.1.4.1.211.1.21.1.50.2.13.2.1 |
fjdaryBtuIndexThe value of this object uniquely identifies this fjdaryBtu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.13.2.1.1 |
fjdaryBtuItemIdThe value of this object indicates the identification number of this
BTU.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.13.2.1.2 |
fjdaryBtuStatusThe value of this object indicates the state of this BTU.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.13.2.1.3 |
fjdaryCe OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.14 |
fjdaryCeCountThe number of CE(controller enclosure)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.14.1 |
fjdaryCeTable SEQUENCE OF FjdaryCeEntry .1.3.6.1.4.1.211.1.21.1.50.2.14.2 |
fjdaryCeEntry FjdaryCeEntry .1.3.6.1.4.1.211.1.21.1.50.2.14.2.1 |
fjdaryCeIndexThe value of this object uniquely identifies this fjdaryCe entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.14.2.1.1 |
fjdaryCeItemIdThe value of this object indicates the identification number of this
CE.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.14.2.1.2 |
fjdaryCeStatusThe value of this object indicates the state of this CE.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.14.2.1.3 |
fjdaryCeinletthml OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.15 |
fjdaryCeinletthmlCountThe number of CE inlet thermal sensor's informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.15.1 |
fjdaryCeinletthmlTable SEQUENCE OF FjdaryCeinletthmlEntry .1.3.6.1.4.1.211.1.21.1.50.2.15.2 |
fjdaryCeinletthmlEntry FjdaryCeinletthmlEntry .1.3.6.1.4.1.211.1.21.1.50.2.15.2.1 |
fjdaryCeinletthmlIndexThe value of this object uniquely identifies this fjdaryCeinletthml
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.15.2.1.1 |
fjdaryCeinletthmlItemIdThe value of this object indicates the identification number of this
CE inlet thermal sensor.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.15.2.1.2 |
fjdaryCeinletthmlStatusThe value of this object indicates the state of this CE inlet thermal
sensor.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.15.2.1.3 |
fjdaryCethermal OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.16 |
fjdaryCethermalCountThe number of CE thermal sensor's informations (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.16.1 |
fjdaryCethermalTable SEQUENCE OF FjdaryCethermalEntry .1.3.6.1.4.1.211.1.21.1.50.2.16.2 |
fjdaryCethermalEntry FjdaryCethermalEntry .1.3.6.1.4.1.211.1.21.1.50.2.16.2.1 |
fjdaryCethermalIndexThe value of this object uniquely identifies this fjdaryCethermal
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.16.2.1.1 |
fjdaryCethermalItemIdThe value of this object indicates the identification number of this
CE thermal sensor.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.16.2.1.2 |
fjdaryCethermalStatusThe value of this object indicates the state of this CE thermal
sensor.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.16.2.1.3 |
fjdaryCpsu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.17 |
fjdaryCpsuCountThe number of CPSU(CE power supply unit)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.17.1 |
fjdaryCpsuTable SEQUENCE OF FjdaryCpsuEntry .1.3.6.1.4.1.211.1.21.1.50.2.17.2 |
fjdaryCpsuEntry FjdaryCpsuEntry .1.3.6.1.4.1.211.1.21.1.50.2.17.2.1 |
fjdaryCpsuIndexThe value of this object uniquely identifies this fjdaryCpsu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.17.2.1.1 |
fjdaryCpsuItemIdThe value of this object indicates the identification number of this
CPSU.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.17.2.1.2 |
fjdaryCpsuStatusThe value of this object indicates the state of this CPSU.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.17.2.1.3 |
fjdarySccb OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.18 |
fjdarySccbCountThe number of SCCB's informations (regardless of their current state)
present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.18.1 |
fjdarySccbTable SEQUENCE OF FjdarySccbEntry .1.3.6.1.4.1.211.1.21.1.50.2.18.2 |
fjdarySccbEntry FjdarySccbEntry .1.3.6.1.4.1.211.1.21.1.50.2.18.2.1 |
fjdarySccbIndexThe value of this object uniquely identifies this fjdarySccb entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.18.2.1.1 |
fjdarySccbItemIdThe value of this object indicates the identification number of this
SCCB.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.18.2.1.2 |
fjdarySccbStatusThe value of this object indicates the state of this SCCB.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.18.2.1.3 |
fjdaryDe OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.19 |
fjdaryDeCountThe number of DE(device enclosure)'s informations (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.19.1 |
fjdaryDeTable SEQUENCE OF FjdaryDeEntry .1.3.6.1.4.1.211.1.21.1.50.2.19.2 |
fjdaryDeEntry FjdaryDeEntry .1.3.6.1.4.1.211.1.21.1.50.2.19.2.1 |
fjdaryDeIndexThe value of this object uniquely identifies this fjdaryDe entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.19.2.1.1 |
fjdaryDeItemIdThe value of this object indicates the identification number of this
DE.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.19.2.1.2 |
fjdaryDeStatusThe value of this object indicates the state of this DE.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.19.2.1.3 |
fjdaryDeIdThe value of this object indicates the identification of this DE.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.19.2.1.4 |
fjdaryDeTypeThe value of this object indicates the type of this DE.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.19.2.1.5 |
fjdaryPbc OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.20 |
fjdaryPbcCountThe number of PBC(port bypass circuit)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.20.1 |
fjdaryPbcTable SEQUENCE OF FjdaryPbcEntry .1.3.6.1.4.1.211.1.21.1.50.2.20.2 |
fjdaryPbcEntry FjdaryPbcEntry .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1 |
fjdaryPbcIndexThe value of this object uniquely identifies this fjdaryPbc entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.1 |
fjdaryPbcItemIdThe value of this object indicates the identification number of this
PBC.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.2 |
fjdaryPbcStatusThe value of this object indicates the state of this PBC.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.3 |
fjdaryPbcTypeThe value of this object indicates the type of this PBC.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.4 |
fjdaryPbcFirmTableThe value of this object indicates the firmware information of this
PBC.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.5 |
fjdaryPbcDeiStatusThe value of this object indicates the DEI cable state of this PBC.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.6 |
fjdaryPbcFcStatus0The value of this object indicates the FC cable state of this PBC.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.7 |
fjdaryPbcFcStatus1The value of this object indicates the FC cable state of this PBC.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.20.2.1.8 |
fjdaryDpsu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.21 |
fjdaryDpsuCountThe number of DPSU(DE power supply unit)'s informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.21.1 |
fjdaryDpsuTable SEQUENCE OF FjdaryDpsuEntry .1.3.6.1.4.1.211.1.21.1.50.2.21.2 |
fjdaryDpsuEntry FjdaryDpsuEntry .1.3.6.1.4.1.211.1.21.1.50.2.21.2.1 |
fjdaryDpsuIndexThe value of this object uniquely identifies this fjdaryDpsu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.21.2.1.1 |
fjdaryDpsuItemIdThe value of this object indicates the identification number of this
DPSU.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.21.2.1.2 |
fjdaryDpsuStatusThe value of this object indicates the state of this DPSU.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.21.2.1.3 |
fjdaryDefan OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.22 |
fjdaryDefanCountThe number of DE FAN's informations (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.22.1 |
fjdaryDefanTable SEQUENCE OF FjdaryDefanEntry .1.3.6.1.4.1.211.1.21.1.50.2.22.2 |
fjdaryDefanEntry FjdaryDefanEntry .1.3.6.1.4.1.211.1.21.1.50.2.22.2.1 |
fjdaryDefanIndexThe value of this object uniquely identifies this fjdaryDefan entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.22.2.1.1 |
fjdaryDefanItemIdThe value of this object indicates the identification number of this
DE FAN.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.22.2.1.2 |
fjdaryDefanStatusThe value of this object indicates the state of this DE FAN.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.22.2.1.3 |
fjdaryDeinletthml OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.23 |
fjdaryDeinletthmlCountThe number of DE inlet thermal sensor's informations (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.23.1 |
fjdaryDeinletthmlTable SEQUENCE OF FjdaryDeinletthmlEntry .1.3.6.1.4.1.211.1.21.1.50.2.23.2 |
fjdaryDeinletthmlEntry FjdaryDeinletthmlEntry .1.3.6.1.4.1.211.1.21.1.50.2.23.2.1 |
fjdaryDeinletthmlIndexThe value of this object uniquely identifies this fjdaryDeinletthml
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.23.2.1.1 |
fjdaryDeinletthmlItemIdThe value of this object indicates the identification number of this
DE inlet thermal sensor.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.23.2.1.2 |
fjdaryDeinletthmlStatusThe value of this object indicates the state of this DE inlet thermal
sensor.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.23.2.1.3 |
fjdaryDethermal OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.24 |
fjdaryDethermalCountThe number of DE thermal sensor's informations (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.24.1 |
fjdaryDethermalTable SEQUENCE OF FjdaryDethermalEntry .1.3.6.1.4.1.211.1.21.1.50.2.24.2 |
fjdaryDethermalEntry FjdaryDethermalEntry .1.3.6.1.4.1.211.1.21.1.50.2.24.2.1 |
fjdaryDethermalIndexThe value of this object uniquely identifies this fjdaryDethermal
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.24.2.1.1 |
fjdaryDethermalItemIdThe value of this object indicates the identification number of this
DE thermal sensor.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.24.2.1.2 |
fjdaryDethermalStatusThe value of this object indicates the state of this DE thermal
sensor.ro FjdaryComponentStatus .1.3.6.1.4.1.211.1.21.1.50.2.24.2.1.3 |
fjdaryDisk OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.25 |
fjdaryDiskCountThe number of DISK's informations (regardless of their current state)
present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.25.1 |
fjdaryDiskTable SEQUENCE OF FjdaryDiskEntry .1.3.6.1.4.1.211.1.21.1.50.2.25.2 |
fjdaryDiskEntry FjdaryDiskEntry .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1 |
fjdaryDiskIndexThe value of this object uniquely identifies this fjdaryDisk entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.1 |
fjdaryDiskItemIdThe value of this object indicates the identification number of this
DISK.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.2 |
fjdaryDiskStatusThe value of this object indicates the state of this DISK.
available : Normal state
broken : Abnormal state
(The data can not be guaranteed)
notavailable : Not available state
(Because the RAID group is not set)
notsupported : Unsupported error state
present : Undefined volume set state
readying : Data readying state
recovering : Data recovering state
partbroken : Abnormal state
spare : Using spare disk state
formatting : Data formatting state
unformatted : Unformatted state
notexist : Not exist
copying : Data copying statero Enumeration .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.3 |
fjdaryDiskPlunThe value of this object indicates the PLUN of this DISK.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.4 |
fjdaryDiskPurposeThe value of this object indicates the purpose of this DISK.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.5 |
fjdaryDiskTypeThe value of this object indicates the type of this DISK.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.6 |
fjdaryDiskWwnThe value of this object indicates the world wide name of this DISK.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.7 |
fjdaryDiskVenderIdThe value of this object indicates the vender of this DISK.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.8 |
fjdaryDiskProductIdThe value of this object indicates the product of this DISK.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.9 |
fjdaryDiskRevisionThe value of this object indicates the revision of this DISK.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.2.25.2.1.10 |
fjdaryLanport OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.2.26 |
fjdaryLanportCountThe number of LAN port's informations (regardless of theier current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.26.1 |
fjdaryLanportTable SEQUENCE OF FjdaryLanportEntry .1.3.6.1.4.1.211.1.21.1.50.2.26.2 |
fjdaryLanportEntry FjdaryLanportEntry .1.3.6.1.4.1.211.1.21.1.50.2.26.2.1 |
fjdaryLanportIndexThe value of this object uniquely identifies this fjdaryLanport
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.2.26.2.1.1 |
fjdaryLanportStatus0The value of this object indicates the MNT port state.
linkup : Link up state
undefined : Undefined state
linkdown : Link down state
unknown : Unknown statero Enumeration .1.3.6.1.4.1.211.1.21.1.50.2.26.2.1.2 |
fjdaryLanportStatus1The value of this object indicates the RMT port state.
linkup : Link up state
undefined : Undefined state
linkdown : Link down state
unknown : Unknown statero Enumeration .1.3.6.1.4.1.211.1.21.1.50.2.26.2.1.3 |
fjdaryLanportStatus2The value of this object indicates the FST port state.
linkup : Link up state
undefined : Undefined state
linkdown : Link down state
unknown : Unknown statero Enumeration .1.3.6.1.4.1.211.1.21.1.50.2.26.2.1.4 |
fjdaryLconfig OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3 |
fjdaryCaPort OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.1 |
fjdaryCaPortCountThe number of CA port's informations (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.1.1 |
fjdaryCaPortTable SEQUENCE OF FjdaryCaPortEntry .1.3.6.1.4.1.211.1.21.1.50.3.1.2 |
fjdaryCaPortEntry FjdaryCaPortEntry .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1 |
fjdaryCaPortIndexThe value of this object uniquely identifies this fjdaryCaPort entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.1 |
fjdaryCaPortPortInfoThe value of this object indicates the port informatiom of this CA
port.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Reserved | Factor | Port Number|
+++++
0x04| Map Number | Security | Host | Method |
| | Mode | Connection| |
+++++
0x08| LoopID | Rate | Class | SFP Type |
+++++
0x0c| RA Mode | XSP | RA Group ID| CM CPU MID |
| | Connection| | |
+++++
0x10| FC Frame Size | MTU Size |
+++++
0x14| Reserved |
+++++
0x18| WWN (Port Name) |
+ +
0x1c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.2 |
fjdaryCaPortiscsiInfoThe value of this object indicates an iscsi informatiom table of this
CA port.
byte 0 byte 1 byte 2 byte 3
+-+-+
0x00| Reserved |
+-+-+
0x04| Reserved | iSCSI Flag |
+-+-+
0x08| Reserved | Name Valid| Reserved |
+-+-+
0x0c| Reserved |
+-+-+ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.3 |
fjdaryCaPortiscsiNameThe value of this object indicates an iscsi name of this CA port.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.4 |
fjdaryCaPortiscsiAliasNameThe value of this object indicates an iscsi alias name of this CA
port.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.5 |
fjdaryCaPortiscsiIpAddressThe value of this object indicates an iscsi ip address of this CA
port.ro IpAddress .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.6 |
fjdaryCaPortiscsiSubnetMaskThe value of this object indicates an iscsi subnet mask of this CA
port.ro IpAddress .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.7 |
fjdaryCaPortiscsiIsnsServerThe value of this object indicates an isns server ip address of this
CA port.ro IpAddress .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.8 |
fjdaryCaPortCuImageThe value of this object indicates a cu image informatiom table of
this CA port.
byte 0 byte 1 byte 2 byte 3
+-+-+
0x00| LCUN 00 | LCUN 01 | LCUN 02 | LCUN 03 |
+-+-+
0x04| LCUN 04 | LCUN 05 | LCUN 06 | LCUN 07 |
+-+-+
0x08| LCUN 08 | LCUN 09 | LCUN 0A | LCUN 0B |
+-+-+
0x0c| LCUN 0C | LCUN 0D | LCUN 0E | LCUN 0F |
+-+-+ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.1.2.1.9 |
fjdaryOlu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.2 |
fjdaryOluCountThe number of OLU's informations entry (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.2.1 |
fjdaryOluTable SEQUENCE OF FjdaryOluEntry .1.3.6.1.4.1.211.1.21.1.50.3.2.2 |
fjdaryOluEntry FjdaryOluEntry .1.3.6.1.4.1.211.1.21.1.50.3.2.2.1 |
fjdaryOluIndexThe value of this object uniquely identifies this fjdaryOlu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.2.2.1.1 |
fjdaryOluInfoTableThe value of this object indicates the OLU information of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| OLU#index*4 information (48 bytes) |
+++++
0x30| OLU#index*4+1 information (48 bytes) |
+++++
0x60| OLU#index*4+2 information (48 bytes) |
+++++
0x90| OLU#index*4+3 information (48 bytes) |
+++++
OLU informateion:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| OLUN | Status |
+++++
0x04| SLU count | Reserved |
+++++
0x08| SLUN 00 | SLUN 01 |
+++++
~ ~
+++++
0x24| SLUN 0E | SLUN 0F |
+++++
0x28| Reserved |
+++++
0x2c| Reserved |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.2.2.1.2 |
fjdaryMlu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.3 |
fjdaryMluCountThe number of MLU's informations entry (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.3.1 |
fjdaryMluTable SEQUENCE OF FjdaryMluEntry .1.3.6.1.4.1.211.1.21.1.50.3.3.2 |
fjdaryMluEntry FjdaryMluEntry .1.3.6.1.4.1.211.1.21.1.50.3.3.2.1 |
fjdaryMluIndexThe value of this object uniquely identifies this fjdaryMlu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.3.2.1.1 |
fjdaryMluInfoTableThe value of this object indicates the MLU information of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| MLU#index*16 information (16 bytes) |
+++++
0x10| MLU#index*16+1 information (16 bytes) |
+++++
~ ~
+++++
0xf0| MLU#index*16+15 information (16 bytes) |
+++++
MLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| MLUN | Status |
+++++
0x04| Type Index | MLU Mode | Reserved |
+++++
0x08| SLUN | LCU No | Reserved |
+++++
0x0c| User Cylinder Count | Reserved |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.3.2.1.2 |
fjdarySlu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.4 |
fjdarySluCountThe number of SLU's informations entry (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.4.1 |
fjdarySluTable SEQUENCE OF FjdarySluEntry .1.3.6.1.4.1.211.1.21.1.50.3.4.2 |
fjdarySluEntry FjdarySluEntry .1.3.6.1.4.1.211.1.21.1.50.3.4.2.1 |
fjdarySluIndexThe value of this object uniquely identifies this fjdarySlu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.4.2.1.1 |
fjdarySluInfoTableThe value of this object indicates the SLU information of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| SLUN | Status |
+++++
0x04| LU Type | Reserved |
+++++
0x08| RLUN | Temporary RLUN |
+++++
0x0c| MLUN | OLUN |
+++++
0x10| Reserved (16 bytes) |
~ ~
0x1c| |
+++++
0x20| Start RLBA |
+ +
0x24| |
+++++
0x28| Temporary Start RLBA |
+ +
0x2c| |
+++++
0x30| Start OLBA |
+ +
0x34| |
+++++
0x38| OLBA Count |
+ +
0x3c| |
+++++
0x40| SLBA Count |
+ +
0x44| |
+++++
0x48| Temporary SLBA Count |
+ +
0x4c| |
+++++
0x50| Start SLBA for OLU |
+ +
0x54| |
+++++
0x58| SLBA Count for OLU |
+ +
0x5c| |
+++++
0x60| Virtual OLBA Count |
+ +
0x64| |
+++++
0x68| Reserved (72 bytes) |
~ ~
0xac| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.4.2.1.2 |
fjdaryRlu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.5 |
fjdaryRluCountThe number of RLU's informations entry (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.5.1 |
fjdaryRluTable SEQUENCE OF FjdaryRluEntry .1.3.6.1.4.1.211.1.21.1.50.3.5.2 |
fjdaryRluEntry FjdaryRluEntry .1.3.6.1.4.1.211.1.21.1.50.3.5.2.1 |
fjdaryRluIndexThe value of this object uniquely identifies this fjdaryRlu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.5.2.1.1 |
fjdaryRluInfoTable0The value of this object indicates the RLU information #0 of this
system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| RLUN | Status |
+++++
0x04| Def CM MID | Curr CM MID| Reserved |
+++++
0x08| RAID Level | RLU Mode | Blockade | RLU Enable |
+++++
0x0c| Reserved |
+++++
0x10| RLBA Count |
+ +
0x14| |
+++++
0x18| Stripe Depth |
+++++
0x1c| Stripe Size |
+++++
0x20| Expanded RLUN | Temporary RLUN |
+++++
0x24| Reserved (12 bytes) |
~ ~
0x2c| |
+++++
0x30| SLU Count | Reserved |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.5.2.1.2 |
fjdaryRluInfoTable1The value of this object indicates the RLU information #1 of this
system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| SLUN 00 | SLUN 01 |
+++++
~ ~
+++++
0xfc| SLUN 7E | SLUN 7F |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.5.2.1.3 |
fjdaryRluInfoTable2The value of this object indicates the RLU information #2 of this
system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| M Disk cnt | Reserved |
+++++
0x04| DLUN 00 | DLUN 01 |
+++++
~ ~
+++++
0x20| DLUN 0E | DLUN 0F |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.5.2.1.4 |
fjdaryDlu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.6 |
fjdaryDluCountThe number of DLU's informations entry (regardless of their current
state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.6.1 |
fjdaryDluTable SEQUENCE OF FjdaryDluEntry .1.3.6.1.4.1.211.1.21.1.50.3.6.2 |
fjdaryDluEntry FjdaryDluEntry .1.3.6.1.4.1.211.1.21.1.50.3.6.2.1 |
fjdaryDluIndexThe value of this object uniquely identifies this fjdaryDlu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.6.2.1.1 |
fjdaryDluInfoTableThe value of this object indicates the DLU information of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| DLUN | Status |
+++++
0x04| RLUN | M Disk No | Reserved |
+++++
0x08| Start DLBA |
+ +
0x0c| |
+++++
0x10| Block Count |
+ +
0x14| |
+++++
0x18| Stripe Depth |
+++++
0x1c| Stripe Size |
+++++
0x20| M Disk cnt | Reserved |
+++++
0x24| Reserved |
+++++
0x28| PLU in Use 00 | PLU in Use 01 |
+++++
~ ~
+++++
0x44| PLU in Use 0E | PLU in Use 0F |
+++++
0x48| Defined PLU 00 | Defined PLU 01 |
+++++
~ ~
+++++
0x64| Defined PLU 0E | Defined PLU 0F |
+++++
0x68| Reserved |
+ +
0x6c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.6.2.1.2 |
fjdaryOpenmap OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.7 |
fjdaryOpenmapCountThe number of open volume mapping table's informations entry
(regardless of their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.7.1 |
fjdaryOpenmapTable SEQUENCE OF FjdaryOpenmapEntry .1.3.6.1.4.1.211.1.21.1.50.3.7.2 |
fjdaryOpenmapEntry FjdaryOpenmapEntry .1.3.6.1.4.1.211.1.21.1.50.3.7.2.1 |
fjdaryOpenmapIndexThe value of this object uniquely identifies this fjdaryOpenmap
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.7.2.1.1 |
fjdaryOpenmapInfoThe value of this object indicates the open volume mapping table
information of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| MAP No | Valid Cnt | CA ModuleID| Port No |
+++++
0x04| Default Affinity Group | Reserved |
+++++
0x08| Reserved |
+ +
0x0c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.7.2.1.2 |
fjdaryOpenmapHostTableThe value of this object indicates the host affinity information of
this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Host #00 | Affinity Group#00 |
+++++
~ ~
+++++
0xfc| Host #3F | Affinity Group#3F |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.7.2.1.3 |
fjdaryLunolu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.8 |
fjdaryLunoluCountThe number of LUN-OLU mapping table's informations entry (regardless
of their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.8.1 |
fjdaryLunoluTable SEQUENCE OF FjdaryLunoluEntry .1.3.6.1.4.1.211.1.21.1.50.3.8.2 |
fjdaryLunoluEntry FjdaryLunoluEntry .1.3.6.1.4.1.211.1.21.1.50.3.8.2.1 |
fjdaryLunoluIndexThe value of this object uniquely identifies this fjdaryLunolu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.8.2.1.1 |
fjdaryLunoluInfoThe value of this object indicates the LUN-OLU mapping table
information of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Affinity Group No | Definition | Reserved |
+++++
0x04| Affinity Group Name (16 bytes) |
~ ~
0x10| |
+++++
0x14| Prev Affinity Group No | Next Affinity Group No |
+++++
0x18| Host Response Table No | Reserved |
+++++
0x1c| Reserved |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.8.2.1.2 |
fjdaryLunoluTable0The value of this object indicates the LUN-OLU mapping table
information(LUN#0 to #127) of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| LUN#0-OLU# | LUN#1-OLU# |
+++++
~ ~
+++++
0xfc| LUN#126-OLU# | LUN#127-OLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.8.2.1.3 |
fjdaryLunoluTable1The value of this object indicates the LUN-OLU mapping table
information(LUN#128 to #255) of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| LUN#128-OLU# | LUN#129-OLU# |
+++++
~ ~
+++++
0xfc| LUN#254-OLU# | LUN#255-OLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.8.2.1.4 |
fjdaryLunoluTable2The value of this object indicates the LUN-OLU mapping table
information(LUN#256 to #383) of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| LUN#256-OLU# | LUN#257-OLU# |
+++++
~ ~
+++++
0xfc| LUN#382-OLU# | LUN#383-OLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.8.2.1.5 |
fjdaryLunoluTable3The value of this object indicates the LUN-OLU mapping table
information(LUN#384 to #511) of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| LUN#384-OLU# | LUN#385-OLU# |
+++++
~ ~
+++++
0xfc| LUN#510-OLU# | LUN#511-OLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.8.2.1.6 |
fjdaryHostwwn OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.9 |
fjdaryHostwwnCountThe number of host wwn table's informations entry (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.9.1 |
fjdaryHostwwnTable SEQUENCE OF FjdaryHostwwnEntry .1.3.6.1.4.1.211.1.21.1.50.3.9.2 |
fjdaryHostwwnEntry FjdaryHostwwnEntry .1.3.6.1.4.1.211.1.21.1.50.3.9.2.1 |
fjdaryHostwwnIndexThe value of this object uniquely identifies this fjdaryHostwwn
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.9.2.1.1 |
fjdaryHostwwnWWNThe value of this object indicates the host wwn of this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Host WWN |
+ +
0x04| |
+++++
0x08| Host Response Table Num | Valid Flag | Reserved |
+++++
0x0c| Reserved (20 bytes) |
~ ~
0x1c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.9.2.1.2 |
fjdaryResetpath OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.10 |
fjdaryResetpathCountThe number of reset path group table's informations entry (regardless
of their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.10.1 |
fjdaryResetpathTable SEQUENCE OF FjdaryResetpathEntry .1.3.6.1.4.1.211.1.21.1.50.3.10.2 |
fjdaryResetpathEntry FjdaryResetpathEntry .1.3.6.1.4.1.211.1.21.1.50.3.10.2.1 |
fjdaryResetpathIndexThe value of this object uniquely identifies this fjdaryResetpath
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.10.2.1.1 |
fjdaryResetpathGroupThe value of this object indicates the reset path group table
information of this system.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.10.2.1.2 |
fjdaryLcu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.11 |
fjdaryLcuCountThe number of LCU information table's entry (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.11.1 |
fjdaryLcuTable SEQUENCE OF FjdaryLcuEntry .1.3.6.1.4.1.211.1.21.1.50.3.11.2 |
fjdaryLcuEntry FjdaryLcuEntry .1.3.6.1.4.1.211.1.21.1.50.3.11.2.1 |
fjdaryLcuIndexThe value of this object uniquely identifies this fjdaryLcu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.11.2.1.1 |
fjdaryLcuInfoTableThe value of this object indicates the LCU information table of this
system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| LCU No | definition | LCU Mode | Cache Mode |
+++++
0x04| Remote Flag| Reserved | SSID |
+++++
0x08| Reserved |
+ +
0x0c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.11.2.1.2 |
fjdaryIoamlu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.12 |
fjdaryIoamluCountThe number of LCU-CA-IOA mapping information table's entry (regardless
of their current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.12.1 |
fjdaryIoamluTable SEQUENCE OF FjdaryIoamluEntry .1.3.6.1.4.1.211.1.21.1.50.3.12.2 |
fjdaryIoamluEntry FjdaryIoamluEntry .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1 |
fjdaryIoamluIndexThe value of this object uniquely identifies this fjdaryIoamlu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.1 |
fjdaryIoamluLCU0The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#0 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.2 |
fjdaryIoamluLCU1The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#0 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.3 |
fjdaryIoamluLCU2The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#1 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.4 |
fjdaryIoamluLCU3The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#1 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.5 |
fjdaryIoamluLCU4The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#2 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.6 |
fjdaryIoamluLCU5The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#2 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.7 |
fjdaryIoamluLCU6The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#3 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.8 |
fjdaryIoamluLCU7The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#3 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.9 |
fjdaryIoamluLCU8The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#4 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.10 |
fjdaryIoamluLCU9The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#4 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.11 |
fjdaryIoamluLCU10The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#5 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.12 |
fjdaryIoamluLCU11The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#5 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.13 |
fjdaryIoamluLCU12The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#6 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.14 |
fjdaryIoamluLCU13The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#6 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.15 |
fjdaryIoamluLCU14The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#7 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.16 |
fjdaryIoamluLCU15The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#7 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.17 |
fjdaryIoamluLCU16The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#8 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.18 |
fjdaryIoamluLCU17The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#8 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.19 |
fjdaryIoamluLCU18The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#9 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.20 |
fjdaryIoamluLCU19The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#9 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.21 |
fjdaryIoamluLCU20The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#10 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.22 |
fjdaryIoamluLCU21The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#10 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.23 |
fjdaryIoamluLCU22The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#11 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.24 |
fjdaryIoamluLCU23The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#11 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.25 |
fjdaryIoamluLCU24The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#12 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.26 |
fjdaryIoamluLCU25The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#12 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.27 |
fjdaryIoamluLCU26The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#13 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.28 |
fjdaryIoamluLCU27The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#13 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.29 |
fjdaryIoamluLCU28The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#14 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.30 |
fjdaryIoamluLCU29The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#14 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.31 |
fjdaryIoamluLCU30The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#15 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.32 |
fjdaryIoamluLCU31The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#15 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.33 |
fjdaryIoamluLCU32The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#16 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.34 |
fjdaryIoamluLCU33The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#16 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.35 |
fjdaryIoamluLCU34The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#17 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.36 |
fjdaryIoamluLCU35The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#17 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.37 |
fjdaryIoamluLCU36The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#18 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.38 |
fjdaryIoamluLCU37The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#18 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.39 |
fjdaryIoamluLCU38The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#19 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.40 |
fjdaryIoamluLCU39The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#19 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.41 |
fjdaryIoamluLCU40The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#20 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.42 |
fjdaryIoamluLCU41The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#20 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.43 |
fjdaryIoamluLCU42The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#21 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.44 |
fjdaryIoamluLCU43The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#21 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.45 |
fjdaryIoamluLCU44The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#22 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.46 |
fjdaryIoamluLCU45The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#22 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.47 |
fjdaryIoamluLCU46The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#23 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.48 |
fjdaryIoamluLCU47The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#23 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.49 |
fjdaryIoamluLCU48The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#24 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.50 |
fjdaryIoamluLCU49The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#24 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.51 |
fjdaryIoamluLCU50The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#25 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.52 |
fjdaryIoamluLCU51The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#25 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.53 |
fjdaryIoamluLCU52The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#26 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.54 |
fjdaryIoamluLCU53The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#26 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.55 |
fjdaryIoamluLCU54The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#27 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.56 |
fjdaryIoamluLCU55The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#27 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.57 |
fjdaryIoamluLCU56The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#28 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.58 |
fjdaryIoamluLCU57The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#28 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.59 |
fjdaryIoamluLCU58The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#29 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.60 |
fjdaryIoamluLCU59The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#29 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.61 |
fjdaryIoamluLCU60The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#30 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.62 |
fjdaryIoamluLCU61The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#30 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.63 |
fjdaryIoamluLCU62The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#31 IOA#0-#127 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#0-MLU# | IOA#1-MLU# |
+++++
~ ~
+++++
0xfc| IOA#126-MLU# | IOA#127-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.64 |
fjdaryIoamluLCU63The value of this object indicates the LCU-CA-IOA mapping information
table of this system.
LCU#31 IOA#128-#255 MLU mapping table
byte 0 byte 1 byte 2 byte 3
+++++
0x00| IOA#128-MLU# | IOA#129-MLU# |
+++++
~ ~
+++++
0xfc| IOA#254-MLU# | IOA#255-MLU# |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.12.2.1.65 |
fjdaryHostiscsi OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.13 |
fjdaryHostiscsiCountThe number of host iscsi configuration table entries.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.13.1 |
fjdaryHostiscsiTable SEQUENCE OF FjdaryHostiscsiEntry .1.3.6.1.4.1.211.1.21.1.50.3.13.2 |
fjdaryHostiscsiEntry FjdaryHostiscsiEntry .1.3.6.1.4.1.211.1.21.1.50.3.13.2.1 |
fjdaryHostiscsiIndexThe value of this object uniquely identifies this fjdaryHostiscsi
entry. This value ranges are from 0 to the value of
fjdaryHostiscsiCount-1.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.13.2.1.1 |
fjdaryHostiscsiDefineThis object shows hostiscsi.
byte 0 byte 1 byte 2 byte 3
+-+-+
0x00| Reserved (12 bytes) |
~ ~
0x08| |
+-+-+
0x0c| Host Response Table No| Valid Flag| Reserved |
+-+-+
0x10| Reserved (16 bytes) |
~ ~
0x1c| |
+-+-+ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.13.2.1.2 |
fjdaryHostiscsiNameThe value of this object shows iscsi name of a host.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.13.2.1.3 |
fjdaryHostiscsiAliasNameThe value of this object shows alias name of a host.ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.13.2.1.4 |
fjdaryHostiscsiIpAddressThe value of this object shows ip address of a host.ro IpAddress .1.3.6.1.4.1.211.1.21.1.50.3.13.2.1.5 |
fjdaryHostResponse OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.3.14 |
fjdaryHostResponseCountThe number of host response informations entry (regardless of their
current state) present on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.14.1 |
fjdaryHostResponseTable SEQUENCE OF FjdaryHostResponseEntry .1.3.6.1.4.1.211.1.21.1.50.3.14.2 |
fjdaryHostResponseEntry FjdaryHostResponseEntry .1.3.6.1.4.1.211.1.21.1.50.3.14.2.1 |
fjdaryHostResponseIndexThe value of this object uniquely identifies this fjdaryHostResponse
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.3.14.2.1.1 |
fjdaryHostResponseInfoTableThe value of this object indicates the host response information of
this system.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Table No | Valid Flag | Reserved |
+++++
0x04| Host Response Name (16 bytes) |
~ ~
0x10| |
+++++
0x14| Reserved |
+++++
0x18| SCC Mode |Host Cmd T.O| Sense Ctrl |
+++++
0x1c| Ope Mode | Reserved |
+++++
0x20| Status Ctrl| Reserved |
+++++
0x24| Reserved (24 bytes) |
~ ~
0x3c| |
+++++
0x40|Inquiry Mode|Inquiry Type|Inquiry Ver.| Reserved |
+++++
0x44| Reserved |
+++++
0x48| Entry Sense| Entry Sense| Entry Sense| Entry Sense|
| Key#0 | Code#0 | SubCode#0 | ConvBit#0 |
+++++
0x4c| ReportSense| ReportSense| ReportSense| ReportSense|
| Key#0 | Code#0 | SubCode#0 | ConvBit#0 |
+++++
~ ~
+++++
0x80| Entry Sense| Entry Sense| Entry Sense| Entry Sense|
| Key#7 | Code#7 | SubCode#7 | ConvBit#7 |
+++++
0x84| ReportSense| ReportSense| ReportSense| ReportSense|
| Key#7 | Code#7 | SubCode#7 | ConvBit#7 |
+++++
0x88| Reserved |
+ +
0x8c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.3.14.2.1.2 |
fjdaryFirm OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.4 |
fjdaryFirmTotalThe value of this object indicates the total firmware information.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Firmware Virsion | Firmware Level |
+++++
0x04| Firmware Suffix |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.4.1 |
fjdaryPerformance OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5 |
fjdaryPfhead OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.1 |
fjdaryPfheadInfHeader that stores performance information.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Model Info | Reserved | Version | Level |
+++++
0x04| Interval Time |
+++++
0x08| Update Time |
+++++
0x0c| Status | Reserved |
+++++
0x10| Reserved (16 bytes) |
~ ~
0x1c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.1.1 |
fjdaryPfopca OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.2 |
fjdaryPfopcaCountThe number of OPEN-CA performance data table's entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.2.1 |
fjdaryPfopcaTable SEQUENCE OF FjdaryPfopcaEntry .1.3.6.1.4.1.211.1.21.1.50.5.2.2 |
fjdaryPfopcaEntry FjdaryPfopcaEntry .1.3.6.1.4.1.211.1.21.1.50.5.2.2.1 |
fjdaryPfopcaIndexThe value of this object uniquely identifies this fjdaryPfopca entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.2.2.1.1 |
fjdaryPfopcaInfo0The value of this object indicates the OPEN-CA Info#0-#1 performance
data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| OPEN-CA Info#0 (128 bytes) |
+++++
0x80| OPEN-CA Info#1 (128 bytes) |
+++++
OPEN-CA Info:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| OPEN-CA ISP Info#0 (64 bytes) |
+++++
0x40| OPEN-CA ISP Info#1 (64 bytes) |
+++++
OPEN-CA ISP Info:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| OPEN-CA Port Info#0 (32 bytes) |
+++++
0x20| OPEN-CA Port Info#1 (32 bytes) |
+++++
OPEN-CA Port Info:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Block Count |
+++++
0x0c| Write Block Count |
+++++
0x10| Reserved (16 bytes) |
~ ~
0x1c| |
+++++
OPEN-CA Port Info (RA Mode):
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Initiator Command Count |
+++++
0x04| Target Command Count |
+++++
0x08| Initiator Block Count |
+++++
0x0c| Target Block Count |
+++++
0x10| Reserved (16 bytes) |
~ ~
0x1c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.2.2.1.2 |
fjdaryPfopcaInfo1The value of this object indicates the OPEN-CA Info#2-#3 performance
data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| OPEN-CA Info#2 (128 bytes) |
+++++
0x80| OPEN-CA Info#3 (128 bytes) |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.2.2.1.3 |
fjdaryPfocca OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.3 |
fjdaryPfoccaCountThe number of OCLINK-CA performance data table's entry on this
system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.3.1 |
fjdaryPfoccaTable SEQUENCE OF FjdaryPfoccaEntry .1.3.6.1.4.1.211.1.21.1.50.5.3.2 |
fjdaryPfoccaEntry FjdaryPfoccaEntry .1.3.6.1.4.1.211.1.21.1.50.5.3.2.1 |
fjdaryPfoccaIndexThe value of this object uniquely identifies this fjdaryPfocca entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.3.2.1.1 |
fjdaryPfoccaInfoThe value of this object indicates the OCLINK-CA performance data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Total CPU Time |
+++++
0x04| Idle CPU Time |
+++++
0x08| Reserved |
+ +
0x0c| |
+++++
0x10| Initial Selection Count |
+++++
0x14| Reconnection Count by CM |
+++++
0x18| Reconnection Count by I/O |
+++++
0x1c| Reconnection Count by Async |
+++++
0x20| Cancel Reconnection Count by CM |
+++++
0x24| Cancel Reconnection Count by CA |
+++++
0x28| Host Connect Time |
+++++
0x2c| CM Connect Time |
+++++
0x30| Host Read Byte Count |
+ +
0x34| |
+++++
0x38| CM Read Byte Count |
+ +
0x3c| |
+++++
0x40| Host Write Byte Count |
+ +
0x44| |
+++++
0x48| CM Write Byte Count |
+ +
0x4c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.3.2.1.2 |
fjdaryPfflca OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.4 |
fjdaryPfflcaCountThe number of FCLINK-CA performance data table's entry on this
system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.4.1 |
fjdaryPfflcaTable SEQUENCE OF FjdaryPfflcaEntry .1.3.6.1.4.1.211.1.21.1.50.5.4.2 |
fjdaryPfflcaEntry FjdaryPfflcaEntry .1.3.6.1.4.1.211.1.21.1.50.5.4.2.1 |
fjdaryPfflcaIndexThe value of this object uniquely identifies this fjdaryPfflca entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.4.2.1.1 |
fjdaryPfflcaInfoThe value of this object indicates the FCLINK-CA Info performance
data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| FCLINK-CA Port Info#0 (64 bytes) |
+++++
0x40| FCLINK-CA Port Info#1 (64 bytes) |
+++++
FCLINK-CA Port Info:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Total CPU Time |
+++++
0x04| Idle CPU Time |
+++++
0x08| Reserved |
+ +
0x0c| |
+++++
0x10| Initial Selection Count |
+++++
0x14| Reconnection Count by I/O |
+++++
0x18| Reconnection Count by Async |
+++++
0x1c| Reserved |
+++++
0x20| Host Read Byte Count |
+ +
0x24| |
+++++
0x28| CM Read Byte Count |
+ +
0x2c| |
+++++
0x30| Host Write Byte Count |
+ +
0x34| |
+++++
0x38| CM Write Byte Count |
+ +
0x3c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.4.2.1.2 |
fjdaryPfdi OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.5 |
fjdaryPfdiCountThe number of DI(drive interface) performance data table's entry on
this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.5.1 |
fjdaryPfdiTable SEQUENCE OF FjdaryPfdiEntry .1.3.6.1.4.1.211.1.21.1.50.5.5.2 |
fjdaryPfdiEntry FjdaryPfdiEntry .1.3.6.1.4.1.211.1.21.1.50.5.5.2.1 |
fjdaryPfdiIndexThe value of this object uniquely identifies this fjdaryPfdi entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.5.2.1.1 |
fjdaryPfdiInfoThe value of this object indicates the DI performance data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| DI Port Info#0 (16 bytes) |
+++++
0x10| DI Port Info#1 (16 bytes) |
+++++
~ ~
+++++
0x70| DI Port Info#7 (16 bytes) |
+++++
DI Port Info:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Block Count |
+++++
0x0c| Write Block Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.5.2.1.2 |
fjdaryPfbrt OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.6 |
fjdaryPfbrtCountThe number of BRT performance data table's entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.6.1 |
fjdaryPfbrtTable SEQUENCE OF FjdaryPfbrtEntry .1.3.6.1.4.1.211.1.21.1.50.5.6.2 |
fjdaryPfbrtEntry FjdaryPfbrtEntry .1.3.6.1.4.1.211.1.21.1.50.5.6.2.1 |
fjdaryPfbrtIndexThe value of this object uniquely identifies this fjdaryPfbrt entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.6.2.1.1 |
fjdaryPfbrtInfo0The value of this object indicates the BRT Info#0-#15 performance
data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| BRT Port Info#0 (16 bytes) |
+++++
0x10| BRT Port Info#1 (16 bytes) |
+++++
~ ~
+++++
0xf0| BRT Port Info#15 (16 bytes) |
+++++
BRT Port Info:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Block Count |
+++++
0x0c| Write Block Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.6.2.1.2 |
fjdaryPfbrtInfo1The value of this object indicates the BRT Info#16-#31 performance
data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| BRT Port Info#16 (16 bytes) |
+++++
0x10| BRT Port Info#17 (16 bytes) |
+++++
~ ~
+++++
0xf0| BRT Port Info#31 (16 bytes) |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.6.2.1.3 |
fjdaryPfbrtInfo2The value of this object indicates the BRT Info#32-#47 performance
data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| BRT Port Info#32 (16 bytes) |
+++++
0x10| BRT Port Info#33 (16 bytes) |
+++++
~ ~
+++++
0xf0| BRT Port Info#47 (16 bytes) |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.6.2.1.4 |
fjdaryPfbrtInfo3The value of this object indicates the BRT Info#48-#63 performance
data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| BRT Port Info#48 (16 bytes) |
+++++
0x10| BRT Port Info#49 (16 bytes) |
+++++
~ ~
+++++
0xf0| BRT Port Info#63 (16 bytes) |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.6.2.1.5 |
fjdaryPfdisk OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.7 |
fjdaryPfdiskCountThe number of DISK performance data table's entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.7.1 |
fjdaryPfdiskTable SEQUENCE OF FjdaryPfdiskEntry .1.3.6.1.4.1.211.1.21.1.50.5.7.2 |
fjdaryPfdiskEntry FjdaryPfdiskEntry .1.3.6.1.4.1.211.1.21.1.50.5.7.2.1 |
fjdaryPfdiskIndexThe value of this object uniquely identifies this fjdaryPfdisk entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.7.2.1.1 |
fjdaryPfdiskInfoThe value of this object indicates the DISK performance data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| DISK Info#index*8 (32 bytes) |
+++++
0x20| DISK Info#index*8+1 (32 bytes) |
+++++
~ ~
+++++
0xe0| DISK Info#index*8+7 (32 bytes) |
+++++
DISK Info:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| PLU | Reserved | Busy Rate |
+++++
0x04| Xfer Rate |
+++++
0x08| Busy Time |
+ +
0x0c| |
+++++
0x10| Read Command Count |
+++++
0x14| Write Command Count |
+++++
0x18| Read Block Count |
+++++
0x1c| Write Block Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.7.2.1.2 |
fjdaryPfdisktime OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.8 |
fjdaryPfdisktimeCountThe number of DISK time performance data table's entry on this
system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.8.1 |
fjdaryPfdisktimeTable SEQUENCE OF FjdaryPfdisktimeEntry .1.3.6.1.4.1.211.1.21.1.50.5.8.2 |
fjdaryPfdisktimeEntry FjdaryPfdisktimeEntry .1.3.6.1.4.1.211.1.21.1.50.5.8.2.1 |
fjdaryPfdisktimeIndexThe value of this object uniquely identifies this fjdaryPfdisktime
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.8.2.1.1 |
fjdaryPfdisktimeInfoThe value of this object indicates the DISK time performance data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Busy Time#index*15 (8 bytes) |
+++++
0x08| Busy Time#index*15+1 (8 bytes) |
+++++
~ ~
+++++
0x70| Busy Time#index*15+14 (8 bytes) |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.8.2.1.2 |
fjdaryPfcm OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.9 |
fjdaryPfcmCountThe number of CM performance data table's entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.9.1 |
fjdaryPfcmTable SEQUENCE OF FjdaryPfcmEntry .1.3.6.1.4.1.211.1.21.1.50.5.9.2 |
fjdaryPfcmEntry FjdaryPfcmEntry .1.3.6.1.4.1.211.1.21.1.50.5.9.2.1 |
fjdaryPfcmIndexThe value of this object uniquely identifies this fjdaryPfcm entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.9.2.1.1 |
fjdaryPfcmInfoThe value of this object indicates the CM performance data.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Total CPU Time |
+++++
0x04| Idle CPU Time |
+++++
0x08| Total SUB CPU Time |
+++++
0x0c| Idle SUB CPU Time |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.9.2.1.2 |
fjdaryPfcacheolu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.10 |
fjdaryPfcacheoluCountThe number of OLU performance data gathered in cache layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.10.1 |
fjdaryPfcacheoluTable SEQUENCE OF FjdaryPfcacheoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.10.2 |
fjdaryPfcacheoluEntry FjdaryPfcacheoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.10.2.1 |
fjdaryPfcacheoluIndexThe value of this object uniquely identifies this fjdaryPfcacheolu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.10.2.1.1 |
fjdaryPfcacheoluInfoThe value of this object indicates the OLU performance data gathered
in cache layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CACHE OLU#index*4 Info (48 bytes) |
+++++
0x30| CACHE OLU#index*4+1 Info (48 bytes) |
+++++
0x60| CACHE OLU#index*4+2 Info (48 bytes) |
+++++
0x90| CACHE OLU#index*4+3 Info (48 bytes) |
+++++
CACHE OLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Hit Count |
+++++
0x0c| Write Hit Count |
+++++
0x10| Pre-fetch Read Hit Count |
+++++
0x14| Read Block Count |
+++++
0x18| Write Block Count |
+++++
0x1c| Staging Count |
+++++
0x20| Writeback Count |
+++++
0x24| Read Miss Staging Count |
+++++
0x28| Sequential Read Count |
+++++
0x2c| Sequential Write Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.10.2.1.2 |
fjdaryPfrscolu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.11 |
fjdaryPfrscoluCountThe number of OLU performance data gathered in resource layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.11.1 |
fjdaryPfrscoluTable SEQUENCE OF FjdaryPfrscoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.11.2 |
fjdaryPfrscoluEntry FjdaryPfrscoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.11.2.1 |
fjdaryPfrscoluIndexThe value of this object uniquely identifies this fjdaryPfrscolu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.11.2.1.1 |
fjdaryPfrscoluInfoThe value of this object indicates the OLU performance data gathered
in resource layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| RSC OLU#index*16 Info (16 bytes) |
+++++
0x10| RSC OLU#index*16+1 Info (16 bytes) |
+++++
~
+++++
0xf0| RSC OLU#index*16+15 Info (16 bytes) |
+++++
RSC OLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Response Time |
+++++
0x04| Write Response Time |
+++++
0x08| Extent Busy Count |
+++++
0x0c| Reserved |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.11.2.1.2 |
fjdaryPfrscrlu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.12 |
fjdaryPfrscrluCountThe number of RLU performance data gathered in resource layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.12.1 |
fjdaryPfrscrluTable SEQUENCE OF FjdaryPfrscrluEntry .1.3.6.1.4.1.211.1.21.1.50.5.12.2 |
fjdaryPfrscrluEntry FjdaryPfrscrluEntry .1.3.6.1.4.1.211.1.21.1.50.5.12.2.1 |
fjdaryPfrscrluIndexThe value of this object uniquely identifies this fjdaryPfrscrlu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.12.2.1.1 |
fjdaryPfrscrluInfoThe value of this object indicates the RLU performance data gathered
in resource layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| RSC RLU#index*16 Info (16 bytes) |
+++++
0x10| RSC RLU#index*16+1 Info (16 bytes) |
+++++
~
+++++
0xf0| RSC RLU#index*16+15 Info (16 bytes) |
+++++
RSC RLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CPU Cross Access Count |
+++++
0x04| Straight Access Count |
+++++
0x08| Cross Access Count |
+++++
0x0c| Reserved |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.12.2.1.2 |
fjdaryPfcopycm OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.13 |
fjdaryPfcopycmCountThe number of CM performance data gathered in copy layer table's entry
on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.13.1 |
fjdaryPfcopycmTable SEQUENCE OF FjdaryPfcopycmEntry .1.3.6.1.4.1.211.1.21.1.50.5.13.2 |
fjdaryPfcopycmEntry FjdaryPfcopycmEntry .1.3.6.1.4.1.211.1.21.1.50.5.13.2.1 |
fjdaryPfcopycmIndexThe value of this object uniquely identifies this fjdaryPfcopycm
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.13.2.1.1 |
fjdaryPfcopycmInfoThe value of this object indicates the CM performance data gathered in
copy layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Copy Remain Count |
+ +
0x04| |
+++++
0x08| Reserved |
+ +
0x0c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.13.2.1.2 |
fjdaryPfcopyslu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.14 |
fjdaryPfcopysluCountThe number of SLU performance data gathered in copy layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.14.1 |
fjdaryPfcopysluTable SEQUENCE OF FjdaryPfcopysluEntry .1.3.6.1.4.1.211.1.21.1.50.5.14.2 |
fjdaryPfcopysluEntry FjdaryPfcopysluEntry .1.3.6.1.4.1.211.1.21.1.50.5.14.2.1 |
fjdaryPfcopysluIndexThe value of this object uniquely identifies this fjdaryPfcopyslu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.14.2.1.1 |
fjdaryPfcopysluInfoThe value of this object indicates the SLU performance data gathered
in copy layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| COPY SLU#index*4 Info (64 bytes) |
+++++
0x40| COPY SLU#index*4+1 Info (64 bytes) |
+++++
0x80| COPY SLU#index*4+2 Info (64 bytes) |
+++++
0xc0| COPY SLU#index*4+3 Info (64 bytes) |
+++++
COPY SLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| EC Source Copy Block Count |
+++++
0x04| EC Destination Copy Block Count |
+++++
0x08| OPC Source Copy Block Count |
+++++
0x0c| OPC Destination Copy Block Count |
+++++
0x10| REC Source Copy Block Count |
+++++
0x14| REC Destination Copy Block Count |
+++++
0x18| Reserved |
+ +
0x1c| |
+++++
0x20| EC Source Copy Area Write Count |
+++++
0x24| OPC Source Un-copy Area Write Count |
+++++
0x28| REC Source Copy Area Write Count |
+++++
0x2c| Busy I/O Count |
+++++
0x30| I/O Limit Busy Count |
+++++
0x34| Extent Busy Count |
+++++
0x38| Cache Busy Count |
+++++
0x3c| Other Busy Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.14.2.1.2 |
fjdaryPfcacheslu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.15 |
fjdaryPfcachesluCountThe number of SLU performance data gathered in cache layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.15.1 |
fjdaryPfcachesluTable SEQUENCE OF FjdaryPfcachesluEntry .1.3.6.1.4.1.211.1.21.1.50.5.15.2 |
fjdaryPfcachesluEntry FjdaryPfcachesluEntry .1.3.6.1.4.1.211.1.21.1.50.5.15.2.1 |
fjdaryPfcachesluIndexThe value of this object uniquely identifies this fjdaryPfcacheslu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.15.2.1.1 |
fjdaryPfcachesluInfoThe value of this object indicates the SLU performance data gathered
in cache layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CACHE SLU#index*4 Info (48 bytes) |
+++++
0x30| CACHE SLU#index*4+1 Info (48 bytes) |
+++++
0x60| CACHE SLU#index*4+2 Info (48 bytes) |
+++++
0x90| CACHE SLU#index*4+3 Info (48 bytes) |
+++++
CACHE SLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Hit Count |
+++++
0x0c| Write Hit Count |
+++++
0x10| Pre-fetch Read Hit Count |
+++++
0x14| Read Block Count |
+++++
0x18| Write Block Count |
+++++
0x1c| Staging Count |
+++++
0x20| Writeback Count |
+++++
0x24| Read Miss Staging Count |
+++++
0x28| Sequential Read Count |
+++++
0x2c| Sequential Write Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.15.2.1.2 |
fjdaryPfrscslu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.16 |
fjdaryPfrscsluCountThe number of SLU performance data gathered in resource layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.16.1 |
fjdaryPfrscsluTable SEQUENCE OF FjdaryPfrscsluEntry .1.3.6.1.4.1.211.1.21.1.50.5.16.2 |
fjdaryPfrscsluEntry FjdaryPfrscsluEntry .1.3.6.1.4.1.211.1.21.1.50.5.16.2.1 |
fjdaryPfrscsluIndexThe value of this object uniquely identifies this fjdaryPfrscslu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.16.2.1.1 |
fjdaryPfrscsluInfoThe value of this object indicates the SLU performance data gathered
in resource layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| RSC SLU#index*32 Info (8 bytes) |
+++++
0x08| RSC SLU#index*32+1 Info (8 bytes) |
+++++
~
+++++
0xf8| RSC SLU#index*32+31 Info (8 bytes) |
+++++
RSC SLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Response Time |
+++++
0x04| Write Response Time |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.16.2.1.2 |
fjdaryPfcachecopyslu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.17 |
fjdaryPfcachecopysluCountThe number of SLU performance data gathered in cache and copy layer
table's entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.17.1 |
fjdaryPfcachecopysluTable SEQUENCE OF FjdaryPfcachecopysluEntry .1.3.6.1.4.1.211.1.21.1.50.5.17.2 |
fjdaryPfcachecopysluEntry FjdaryPfcachecopysluEntry .1.3.6.1.4.1.211.1.21.1.50.5.17.2.1 |
fjdaryPfcachecopysluIndexThe value of this object uniquely identifies this fjdaryPfcachecopyslu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.17.2.1.1 |
fjdaryPfcachecopysluInfoThe value of this object indicates the SLU performance data gathered
in cache and copy layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CACHE COPY SLU#index*4 Info (48 bytes) |
+++++
0x30| CACHE COPY SLU#index*4+1 Info (48 bytes) |
+++++
0x60| CACHE COPY SLU#index*4+2 Info (48 bytes) |
+++++
0x90| CACHE COPY SLU#index*4+3 Info (48 bytes) |
+++++
CACHE COPY SLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Hit Count |
+++++
0x0c| Write Hit Count |
+++++
0x10| Pre-fetch Read Hit Count |
+++++
0x14| Read Block Count |
+++++
0x18| Write Block Count |
+++++
0x1c| Staging Count |
+++++
0x20| Write back Count |
+++++
0x24| Read Miss Staging Count |
+++++
0x28| Sequential Read Count |
+++++
0x2c| Sequential Write Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.17.2.1.2 |
fjdaryPfcachesdvslu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.18 |
fjdaryPfcachesdvsluCountThe number of SLU performance data gathered in cache and sdv layer
table's entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.18.1 |
fjdaryPfcachesdvsluTable SEQUENCE OF FjdaryPfcachesdvsluEntry .1.3.6.1.4.1.211.1.21.1.50.5.18.2 |
fjdaryPfcachesdvsluEntry FjdaryPfcachesdvsluEntry .1.3.6.1.4.1.211.1.21.1.50.5.18.2.1 |
fjdaryPfcachesdvsluIndexThe value of this object uniquely identifies this fjdaryPfcachesdvslu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.18.2.1.1 |
fjdaryPfcachesdvsluInfoThe value of this object indicates the SLU performance data gathered
in cache and sdv layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CACHE SDV SLU#index*4 Info (64 bytes) |
+++++
0x40| CACHE SDV SLU#index*4+1 Info (64 bytes) |
+++++
0x80| CACHE SDV SLU#index*4+2 Info (64 bytes) |
+++++
0xc0| CACHE SDV SLU#index*4+3 Info (64 bytes) |
+++++
CACHE SDV SLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Hit Count |
+++++
0x0c| Write Hit Count |
+++++
0x10| Pre-fetch Read Hit Count |
+++++
0x14| Read Block Count |
+++++
0x18| Write Block Count |
+++++
0x1c| Staging Count |
+++++
0x20| Write back Count |
+++++
0x24| Read Miss Staging Count |
+++++
0x28| Sequential Read Count |
+++++
0x2c| Sequential Write Count |
+++++
0x30| Pre-fetch Staging Count |
+++++
0x34| Pre-fetch Staging Purge Count |
+++++
0x38| Reserved |
+ +
0x3c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.18.2.1.2 |
fjdaryPfcachecopyolu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.19 |
fjdaryPfcachecopyoluCountThe number of OLU performance data gathered in cache and copy layer
table's entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.19.1 |
fjdaryPfcachecopyoluTable SEQUENCE OF FjdaryPfcachecopyoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.19.2 |
fjdaryPfcachecopyoluEntry FjdaryPfcachecopyoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.19.2.1 |
fjdaryPfcachecopyoluIndexThe value of this object uniquely identifies this fjdaryPfcachecopyolu
entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.19.2.1.1 |
fjdaryPfcachecopyoluInfoThe value of this object indicates the OLU performance data gathered
in cache and copy layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CACHE COPY OLU#index*4 Info (48 bytes) |
+++++
0x30| CACHE COPY OLU#index*4+1 Info (48 bytes) |
+++++
0x60| CACHE COPY OLU#index*4+2 Info (48 bytes) |
+++++
0x90| CACHE COPY OLU#index*4+3 Info (48 bytes) |
+++++
CACHE COPY OLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Read Command Count |
+++++
0x04| Write Command Count |
+++++
0x08| Read Hit Count |
+++++
0x0c| Write Hit Count |
+++++
0x10| Pre-fetch Read Hit Count |
+++++
0x14| Read Block Count |
+++++
0x18| Write Block Count |
+++++
0x1c| Staging Count |
+++++
0x20| Write back Count |
+++++
0x24| Read Miss Staging Count |
+++++
0x28| Sequential Read Count |
+++++
0x2c| Sequential Write Count |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.19.2.1.2 |
fjdaryPfcachecommonolu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.20 |
fjdaryPfcachecommonoluCountThe number of OLU performance data gathered in cache layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.20.1 |
fjdaryPfcachecommonoluTable SEQUENCE OF FjdaryPfcachecommonoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.20.2 |
fjdaryPfcachecommonoluEntry FjdaryPfcachecommonoluEntry .1.3.6.1.4.1.211.1.21.1.50.5.20.2.1 |
fjdaryPfcachecommonoluIndexThe value of this object uniquely identifies this
fjdaryPfcachecommonolu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.20.2.1.1 |
fjdaryPfcachecommonoluInfoThe value of this object indicates the SLU performance data gathered
in cache layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CACHE COMMON OLU#index*16 Info (16 bytes) |
+++++
0x10| CACHE COMMON OLU#index*16+1 Info (16 bytes) |
+++++
~
+++++
0xf0| CACHE COMMON OLU#index*16+15 Info (16 bytes) |
+++++
CACHE COMMON OLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Pre-fetch Staging Count |
+++++
0x04| Pre-fetch Staging Purge Count |
+++++
0x08| Reserved |
+ +
0x0c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.20.2.1.2 |
fjdaryPfcachecommonslu OBJECT IDENTIFIER .1.3.6.1.4.1.211.1.21.1.50.5.21 |
fjdaryPfcachecommonsluCountThe number of SLU performance data gathered in cache layer table's
entry on this system.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.21.1 |
fjdaryPfcachecommonsluTable SEQUENCE OF FjdaryPfcachecommonsluEntry .1.3.6.1.4.1.211.1.21.1.50.5.21.2 |
fjdaryPfcachecommonsluEntry FjdaryPfcachecommonsluEntry .1.3.6.1.4.1.211.1.21.1.50.5.21.2.1 |
fjdaryPfcachecommonsluIndexThe value of this object uniquely identifies this
fjdaryPfcachecommonslu entry.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.5.21.2.1.1 |
fjdaryPfcachecommonsluInfoThe value of this object indicates the SLU performance data gathered
in cache layer.
byte 0 byte 1 byte 2 byte 3
+++++
0x00| CACHE COMMON SLU#index*16 Info (16 bytes) |
+++++
0x10| CACHE COMMON SLU#index*16+1 Info (16 bytes) |
+++++
~
+++++
0xf0| CACHE COMMON SLU#index*16+15 Info (16 bytes) |
+++++
CACHE COMMON SLU information:
byte 0 byte 1 byte 2 byte 3
+++++
0x00| Pre-fetch Staging Count |
+++++
0x04| Pre-fetch Staging Purge Count |
+++++
0x08| Reserved |
+ +
0x0c| |
+++++ro OCTET STRING .1.3.6.1.4.1.211.1.21.1.50.5.21.2.1.2 |
fjdaryUnitStatusOverall status of this system.ro Enumeration .1.3.6.1.4.1.211.1.21.1.50.6 |
fjdaryTrapItemIdThis object is used to store the identification number of parts for
which maintenance is necessary when trap is transmitted.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.7 |
fjdaryTrapSensorInfoThis object is used to store detail information of sensor when trap is
transmitted.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.8 |
fjdaryTrapMaintenanceInfoThis object is used to store detail information of maintenance when
trap is transmitted.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.9 |
fjdaryTrapWarningInfoThis object is used to store detail information of warning when trap
is transmitted.ro INTEGER .1.3.6.1.4.1.211.1.21.1.50.10 |
fjdaryTrapMessageThis object is used to store detail messages when all trap is
transmitted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.211.1.21.1.50.11 |
application OBJECT IDENTIFIER .1.3.6.1.4.1.211.4 |
aplNetwork OBJECT IDENTIFIER .1.3.6.1.4.1.211.4.1 |
aplNetDevice OBJECT IDENTIFIER .1.3.6.1.4.1.211.4.1.1 |
aplNetStorage OBJECT IDENTIFIER .1.3.6.1.4.1.211.4.1.1.126 |
aplNetNsp OBJECT IDENTIFIER .1.3.6.1.4.1.211.4.1.1.126.1 |
aplNetFjdarye50 OBJECT IDENTIFIER .1.3.6.1.4.1.211.4.1.1.126.1.50 |
fjdarye50ConfigChangeA configChange trap signifies that the sending protocol entity
recognizes the change in configuration information. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.0 |
fjdarye50FirmChangeA firmChange trap signifies that the exchange of the firmware was
executed. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.1 |
fjdarye50ItemFaultA itemFault trap signifies that device was failed. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.2 |
fjdarye50BatteryExpirationA batteryExpiration trap signifies that the exchange time of the
battery comes. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.3 |
fjdarye50RebuildNotStartA rebuildNotStart trap signifies that not to be able to begin to
execute the rebuild because there is no spare disk. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.4 |
fjdarye50ItemWarningA itemWarning trap signifies that device was warning. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.5 |
fjdarye50SensorStatusChangeA sensorStatusChange trap signifies that environment sensor status
changes. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.6 |
fjdarye50MaintenanceRequiredA maintenanceRequired trap signifies that maintenance information. TRAP-TYPE .1.3.6.1.4.1.211.4.1.1.126.1.50.0.7 |