FASTPATH-BOXSERVICES-PRIVATE-MIB
AI MIB Summary
The FASTPATH-BOXSERVICES-PRIVATE-MIB provides vendor-specific monitoring and management capabilities for Broadcom FastPath hardware appliances, exposing internal box service states, resource utilization metrics, and proprietary operational counters not covered by standard MIBs. This module enables granular visibility into the underlying FastPath engine's performance and health, facilitating the diagnosis of service-specific anomalies and resource bottlenecks on Broadcom-based network devices.
The Broadcom Private MIB for FASTPATH Box Services Feature.
Main OID:
fastPathBoxServices.1.3.6.1.4.1.4413.1.1.43
39
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
39 total| Object Name |
|---|
fastPathBoxServicesThe Broadcom Private MIB for FASTPATH Box Services Feature. MODULE-IDENTITY .1.3.6.1.4.1.4413.1.1.43 |
fastPathBoxServicesTraps OBJECT IDENTIFIER .1.3.6.1.4.1.4413.1.1.43.0 |
boxsFanStateChangeTrap is sent when fan state change happens. NOTIFICATION-TYPE .1.3.6.1.4.1.4413.1.1.43.0.1 |
boxsPowSupplyStateChangeTrap is sent when power supply state change happens. NOTIFICATION-TYPE .1.3.6.1.4.1.4413.1.1.43.0.2 |
boxsTemperatureChangeTrap is sent when temperature is changing and crossing any of the thresholds NOTIFICATION-TYPE .1.3.6.1.4.1.4413.1.1.43.0.3 |
boxServicesGroup OBJECT IDENTIFIER .1.3.6.1.4.1.4413.1.1.43.1 |
boxServicesNormalTempRangeMinLower boundary of normal temperature range.rw INTEGER (-100..100) .1.3.6.1.4.1.4413.1.1.43.1.1 |
boxServicesNormalTempRangeMaxUpper boundary of normal temperature range.rw INTEGER (-100..100) .1.3.6.1.4.1.4413.1.1.43.1.2 |
boxServicesTemperatureTrapEnableEnable or disable temperature change event trap, raised when temperature crosses boundaries of normal rangerw Enumeration .1.3.6.1.4.1.4413.1.1.43.1.3 |
boxServicesPSMStateTrapEnableEnable or disable Power Supply Module state change trap.rw Enumeration .1.3.6.1.4.1.4413.1.1.43.1.4 |
boxServicesFanStateTrapEnableEnable or disable Fan state change trap.rw Enumeration .1.3.6.1.4.1.4413.1.1.43.1.5 |
boxServicesFansTableFan SEQUENCE OF BoxServicesFansEntry .1.3.6.1.4.1.4413.1.1.43.1.6 |
boxServicesFansEntryBox Services Fan Entry BoxServicesFansEntry .1.3.6.1.4.1.4413.1.1.43.1.6.1 |
boxServicesFansIndexUnique index of fan table entryro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.6.1.1 |
boxServicesFanItemTypeThe type of fanro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.6.1.2 |
boxServicesFanItemStateThe status of fanro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.6.1.3 |
boxServicesFanSpeedThe speed of fanro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.6.1.4 |
boxServicesFanDutyLevelThe duty level of fan, in percentsro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.6.1.5 |
boxServicesPowSuppliesTablePower supply SEQUENCE OF BoxServicesPowSuppliesEntry .1.3.6.1.4.1.4413.1.1.43.1.7 |
boxServicesPowSuppliesEntryBox Services Power Supply Entry BoxServicesPowSuppliesEntry .1.3.6.1.4.1.4413.1.1.43.1.7.1 |
boxServicesPowSupplyIndexUnique index of power supply table entryro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.7.1.1 |
boxServicesPowSupplyItemTypeThe type of power supplyro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.7.1.2 |
boxServicesPowSupplyItemStateThe status of power supplyro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.7.1.3 |
boxServicesTempSensorsTableTemperature sensor
This table has been obsoleted by boxServicesStackTempSensorsTableobsolete SEQUENCE OF BoxServicesTempSensorsEntry .1.3.6.1.4.1.4413.1.1.43.1.8 |
boxServicesTempSensorsEntryBox Services Temperature Sensor Entry BoxServicesTempSensorsEntry .1.3.6.1.4.1.4413.1.1.43.1.8.1 |
boxServicesTempSensorIndexUnique index of temperature sensor table entryro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.8.1.1 |
boxServicesTempSensorTypeThe type of temperature sensorro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.8.1.2 |
boxServicesTempSensorStateThe state of temperature sensorro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.8.1.3 |
boxServicesTempSensorTemperatureThe temperature value reported by sensorro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.8.1.4 |
boxServicesStackTempSensorsTableTemperature sensor SEQUENCE OF BoxServicesStackTempSensorsEntry .1.3.6.1.4.1.4413.1.1.43.1.9 |
boxServicesStackTempSensorsEntryBox Services Temperature Sensor Entry BoxServicesStackTempSensorsEntry .1.3.6.1.4.1.4413.1.1.43.1.9.1 |
boxServicesUnitIndexIndex of a stack unitro INTEGER .1.3.6.1.4.1.4413.1.1.43.1.9.1.1 |
boxServicesStackTempSensorIndexUnique index of temperature sensor table entryro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.9.1.2 |
boxServicesStackTempSensorTypeThe type of temperature sensorro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.9.1.3 |
boxServicesStackTempSensorStateThe state of temperature sensorro Enumeration .1.3.6.1.4.1.4413.1.1.43.1.9.1.4 |
boxServicesStackTempSensorTemperatureThe temperature value reported by sensorro Integer32 .1.3.6.1.4.1.4413.1.1.43.1.9.1.5 |
boxServicesNotificationsGroup OBJECT IDENTIFIER .1.3.6.1.4.1.4413.1.1.43.2 |
boxsItemStateChangeEventThis event describes states of the fan or power supply.
insertion - hot-pluggable fan or power supply was inserted
removal - hot-pluggable fan or power supply was removed
becomeoperational - fan or power supply became operational after failure state
failure - fan or power supply failure happened, i.e. it is not able to perform its functionsro Enumeration .1.3.6.1.4.1.4413.1.1.43.2.1 |
boxsTemperatureChangeEventThis event describes change of the temperature.
To avoid flipping on boundary conditions, it is allowed to send the trap
taking into account some margin around thresholds.
abovethreshold - temperature increased and crossed upper threshold value
belowthreshold - temperature decreased and crossed lower threshold value
withinnormalrange - temperature returned to normal range (between threshold)ro Enumeration .1.3.6.1.4.1.4413.1.1.43.2.2 |