EXTREME-NETSIGHT-ALARM-MIB
The EXTREME-NETSIGHT-ALARM-MIB enables the Extreme Networks Netsight Alarm Manager to transmit specific network event notifications and alarm states to external SNMP trap receivers for centralized monitoring. This module facilitates the real-time alerting of critical infrastructure conditions, such as device failures, link status changes, and threshold violations, within the Enterasys/Extreme enterprise management ecosystem.
Imported Objects
Objects
127 total| Object Name |
|---|
extremeNetsightAlarmMIBThis MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID pertaining to definitions and notifications for the Extreme Netsight network management software. This MIB defines a set of notifications that the Netsight Alarm Manager can send to another SNMP trap receiver. MODULE-IDENTITY .1.3.6.1.4.1.5624.1.2.105 |
extremeNetsightAlarmObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5624.1.2.105.1 |
extremeNetsightAlarmNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.5624.1.2.105.1.0 |
extremeNetsightAlarmNotificationThis notification indicates that an alarm was triggered and contains information related to that alarm. Note that this notification is generic and MAY not be used when a more specific notification is defined for a given alarm. NOTE: The list of OBJECTS defined for this alarm will act as a template for all other notifications defined in this group and they should include the same list. NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.1 |
extremeNetsightAlarmDeviceUpDevice Up NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.2 |
extremeNetsightAlarmDeviceDownDevice Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.3 |
extremeNetsightAlarmLinkUpLink Up NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.4 |
extremeNetsightAlarmLinkDownLink Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.5 |
extremeNetsightAlarmFanOKFan OK NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.6 |
extremeNetsightAlarmFanFailureFan Failure NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.7 |
extremeNetsightAlarmPowerSupplyNormalPower supply normal NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.8 |
extremeNetsightAlarmPowerSupplyFailedPower supply failed NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.9 |
extremeNetsightAlarmMultiAuthMaxUsersReachedMultiAuth max users reached NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.10 |
extremeNetsightAlarmMultiAuthModuleMaxUsersReachedMultiAuth module max users reached NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.11 |
extremeNetsightAlarmMultiAuthSystemMaxUsersReachedMultiAuth system max users reached NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.12 |
extremeNetsightAlarmOSPFConflictingPacketOSPF Conflicting packet NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.13 |
extremeNetsightAlarmSpanguardSpanguard NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.14 |
extremeNetsightAlarmMSTPLoopProtectEventMSTP Loop Protect Event NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.15 |
extremeNetsightAlarmSTPDiagnosticMSTISTP Diagnostic MSTI NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.16 |
extremeNetsightAlarmSTPDiagnosticCISTSTP Diagnostic CIST NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.17 |
extremeNetsightAlarmColdStartCold start NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.18 |
extremeNetsightAlarmWarmStartWarm start NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.19 |
extremeNetsightAlarmMultiAuthSuccessMultiAuth Success NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.20 |
extremeNetsightAlarmMultiAuthFailedMultiAuth Failed NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.21 |
extremeNetsightAlarmMultiAuthTerminatedMultiAuth terminated NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.22 |
extremeNetsightAlarmConfigurationChangedConfiguration Changed NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.23 |
extremeNetsightAlarmAPInServiceAP In Service NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.24 |
extremeNetsightAlarmAPOutOfServiceAP Out of Service NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.25 |
extremeNetsightAlarmAPRadioChangeAP Radio Change NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.26 |
extremeNetsightAlarmAPRadioOnOffAP Radio OnOff NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.27 |
extremeNetsightAlarmInterferenceStoppedInterference Stopped NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.28 |
extremeNetsightAlarmInterferenceStartedInterference Started NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.29 |
extremeNetsightAlarmThreatInactiveThreat Inactive NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.30 |
extremeNetsightAlarmThreatActiveThreat Active NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.31 |
extremeNetsightAlarmApplianceDiskUsageAppliance Disk Usage NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.32 |
extremeNetsightAlarmDatabaseBackupDiskUsageDatabase Backup Disk Usage NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.33 |
extremeNetsightAlarmRogueInactiveRogue Inactive NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.34 |
extremeNetsightAlarmRogueActiveRogue Active NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.35 |
extremeNetsightAlarmIPMIEventIPMI Event NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.36 |
extremeNetsightAlarmACPowerRecoveredAC Power Recovered NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.37 |
extremeNetsightAlarmACPowerLostAC Power Lost NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.38 |
extremeNetsightAlarmDriveFaultRecoveredDrive Fault Recovered NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.39 |
extremeNetsightAlarmDriveFaultDrive Fault NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.40 |
extremeNetsightAlarmApplicationAnalyticsLicenseViolationClearApplication Analytics License Violation Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.41 |
extremeNetsightAlarmApplicationAnalyticsLicenseViolationApplication Analytics License Violation NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.42 |
extremeNetsightAlarmApplicationAnalyticsApplianceUpApplication Analytics Appliance Up NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.43 |
extremeNetsightAlarmApplicationAnalyticsApplianceDownApplication Analytics Appliance Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.44 |
extremeNetsightAlarmNACApplianceUpNAC Appliance Up NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.45 |
extremeNetsightAlarmNACApplianceDownNAC Appliance Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.46 |
extremeNetsightAlarmNACLicenseViolationClearNAC License Violation Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.47 |
extremeNetsightAlarmNACLicenseViolationNAC License Violation NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.48 |
extremeNetsightAlarmNACAssessmentLicenseViolationClearNAC Assessment License Violation Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.49 |
extremeNetsightAlarmNACAssessmentLicenseViolationNAC Assessment License Violation NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.50 |
extremeNetsightAlarmNACLostContactWithSwitchClearNAC Lost Contact with Switch Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.51 |
extremeNetsightAlarmNACLostContactWithSwitchNAC Lost Contact with Switch NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.52 |
extremeNetsightAlarmNACLostPartialContactWithSwitchClearNAC Lost Partial Contact with Switch Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.53 |
extremeNetsightAlarmNACLostPartialContactWithSwitchNAC Lost Partial Contact with Switch NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.54 |
extremeNetsightAlarmNACLostContactWithRADIUSServerClearNAC Lost Contact with RADIUS Server Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.55 |
extremeNetsightAlarmNACLostContactWithRADIUSServerNAC Lost Contact with RADIUS Server NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.56 |
extremeNetsightAlarmNACLostContactWithLDAPServiceClearNAC Lost Contact with LDAP Service Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.57 |
extremeNetsightAlarmNACLostContactWithLDAPServiceNAC Lost Contact with LDAP Service NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.58 |
extremeNetsightAlarmNACLostPartialContactWithLDAPServiceClearNAC Lost Partial Contact with LDAP Service Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.59 |
extremeNetsightAlarmNACLostPartialContactWithLDAPServiceNAC Lost Partial Contact with LDAP Service NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.60 |
extremeNetsightAlarmNACRFC3576ErrorClearNAC RFC 3576 Error Clear NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.61 |
extremeNetsightAlarmNACRFC3576ErrorNAC RFC 3576 Error NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.62 |
extremeNetsightAlarmNACDatabaseTableServiceIsUpNAC Database Table Service is up NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.63 |
extremeNetsightAlarmNACDatabaseTableServiceDownNAC Database Table Service down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.64 |
extremeNetsightAlarmNACRADIUSRequestsWarningThresholdRectifiedNAC RADIUS Requests Warning Threshold Rectified NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.65 |
extremeNetsightAlarmNACRADIUSRequestsWarningThresholdExceededNAC RADIUS Requests Warning Threshold Exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.66 |
extremeNetsightAlarmNACRADIUSRequestsCriticalThresholdRectifiedNAC RADIUS Requests Critical Threshold Rectified NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.67 |
extremeNetsightAlarmNACRADIUSRequestsCriticalThresholdExceededNAC RADIUS Requests Critical Threshold Exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.68 |
extremeNetsightAlarmNACCertificateUpdatedNAC Certificate Updated NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.69 |
extremeNetsightAlarmNACCertificateHasInvalidDateNAC Certificate has Invalid Date NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.70 |
extremeNetsightAlarmNACCertificateWarningClearedNAC Certificate Warning Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.71 |
extremeNetsightAlarmNACCertificateExpiringWarningNAC Certificate Expiring Warning NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.72 |
extremeNetsightAlarmNACCertificateNoticeClearedNAC Certificate Notice Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.73 |
extremeNetsightAlarmNACCertificateExpiringNoticeNAC Certificate Expiring Notice NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.74 |
extremeNetsightAlarmNACDuplicateSNMPEngineIDClearedNAC Duplicate SNMP Engine ID Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.75 |
extremeNetsightAlarmNACDuplicateSNMPEngineIDFoundNAC Duplicate SNMP Engine ID Found NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.76 |
extremeNetsightAlarmDeviceTopologyChangeDevice Topology Change NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.77 |
extremeNetsightAlarmDevicePercentCPUDevice % CPU NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.78 |
extremeNetsightAlarmDeviceMemoryPercentUsageDevice Memory % Usage NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.79 |
extremeNetsightAlarmHostPercentCPUHost % CPU NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.80 |
extremeNetsightAlarmHostDiskPercentUsageHost Disk % Usage NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.81 |
extremeNetsightAlarmHostMemoryPercentUsageHost Memory % Usage NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.82 |
extremeNetsightAlarmInterfacePercentUsageInterface % Usage NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.83 |
extremeNetsightAlarmInterfacePercentValidPacketsInterface % Valid Packets NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.84 |
extremeNetsightAlarmHistoricalPersistenceResumedHistorical Persistence Resumed NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.85 |
extremeNetsightAlarmHistoricalPersistenceSuspendedHistorical Persistence Suspended NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.86 |
extremeNetsightAlarmAnalyticsPersistenceResumedAnalytics Persistence Resumed NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.87 |
extremeNetsightAlarmAnalyticsPersistenceSuspendedAnalytics Persistence Suspended NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.88 |
extremeNetsightAlarmControllerEstablishedSSHConnectionController Established SSH Connection NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.89 |
extremeNetsightAlarmControllerFailedSSHConnectionController Failed SSH Connection NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.90 |
extremeNetsightAlarmServerHeapMemoryOKServer Heap Memory OK NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.91 |
extremeNetsightAlarmServerHeapMemoryLowServer Heap Memory Low NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.92 |
extremeNetsightAlarmClientMACAvailabilityLowClient MAC Availability Low NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.93 |
extremeNetsightAlarmClientMACIPChangesHighClient MAC IP Changes High NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.94 |
extremeNetsightAlarmNACEntriesPerGroupPerfThresholdRectifiedNAC Entries Per Group Performance Threshold Rectified NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.95 |
extremeNetsightAlarmNACEntriesPerGroupPerfThresholdExceededNAC Entries Per Group Performance Threshold Exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.96 |
extremeNetsightAlarmNACCertificateUsesMD5SignatureClearedNAC Certificate Uses MD5 Signature Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.97 |
extremeNetsightAlarmNACCertificateUsesMD5SignatureNoticeNAC Certificate Uses MD5 Signature Notice NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.98 |
extremeNetsightAlarmNACWinbinddProcessClearedNAC winbindd Process Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.99 |
extremeNetsightAlarmNACWinbinddProcessDownNAC winbindd Process Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.100 |
extremeNetsightAlarmNACSquidProcessClearedNAC squid Process Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.101 |
extremeNetsightAlarmNACSquidProcessDownNAC squid Process Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.102 |
extremeNetsightAlarmNACRadiusdProcessClearedNAC radiusd Process Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.103 |
extremeNetsightAlarmNACRadiusdProcessDownNAC radiusd Process Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.104 |
extremeNetsightAlarmNACDnsproxyProcessClearedNAC dnsproxy Process Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.105 |
extremeNetsightAlarmNACDnsproxyProcessDownNAC dnsproxy Process Down NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.106 |
extremeNetsightAlarmNACIPMICriticalEventClearedNAC IPMI Critical Event Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.107 |
extremeNetsightAlarmNACIPMICriticalEventNAC IPMI Critical Event NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.108 |
extremeNetsightAlarmNACDNSServersUnreachableClearedNAC DNS Servers Unreachable Cleared NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.109 |
extremeNetsightAlarmNACDNSServersUnreachableNAC DNS Servers Unreachable NOTIFICATION-TYPE .1.3.6.1.4.1.5624.1.2.105.1.0.110 |
extremeNetsightAlarmVars OBJECT IDENTIFIER .1.3.6.1.4.1.5624.1.2.105.1.1 |
extremeNetsightAlarmMessageThe message describing the specific alarm triggered.ro OCTET STRING .1.3.6.1.4.1.5624.1.2.105.1.1.1 |
extremeNetsightAlarmSeverityThe severity of an alarm. Lower values signify more serious conditions, whereas higher values are less critical.ro Enumeration .1.3.6.1.4.1.5624.1.2.105.1.1.2 |
extremeNetsightAlarmTimestampThe date and time, in device local time, when the alarm occurred.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.5624.1.2.105.1.1.3 |
extremeNetsightAlarmSourceDeviceAddressTypeThe address type of extremeNetsightAlarmSourceDeviceAddress.ro InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.5624.1.2.105.1.1.4 |
extremeNetsightAlarmSourceDeviceAddressThe address of the device that triggered this alarm. This may be the address of the Netsight server itself or a remote device managed by Netsight.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.5624.1.2.105.1.1.5 |
extremeNetsightAlarmSubcomponentAdditional event specific data for this alarm (e.g. interface number). Note that in most cases there is no such data, and this object will be an empty string.ro OCTET STRING .1.3.6.1.4.1.5624.1.2.105.1.1.6 |
extremeNetsightAlarmConformance OBJECT IDENTIFIER .1.3.6.1.4.1.5624.1.2.105.2 |
extremeNetsightAlarmGroups OBJECT IDENTIFIER .1.3.6.1.4.1.5624.1.2.105.2.1 |
extremeNetsightAlarmSettingsA collection of objects for formatting notifications in the Extreme Netsight Alarm MIB. Unknown .1.3.6.1.4.1.5624.1.2.105.2.1.1 |
extremeNetsightAlarmGenericNotificationGroupA collection of objects required for reporting notifications with the Extreme Netsight Alarm MIB. Unknown .1.3.6.1.4.1.5624.1.2.105.2.1.2 |
extremeNetsightAlarmSpecificNotificationGroupA collection of objects required for reporting notifications with the Extreme Netsight Alarm MIB. Unknown .1.3.6.1.4.1.5624.1.2.105.2.1.3 |
extremeNetsightAlarmCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.5624.1.2.105.2.2 |
extremeNetsightAlarmComplianceGroupThe compliance statement for devices that support the Extreme Netsight Alarm MIB. Unknown .1.3.6.1.4.1.5624.1.2.105.2.2.1 |
More MIBs from Enterasys
Browse all EnterasysMIBs →The ENTERASYS-OIDS-MIB module provides the foundational Object Identifier (OID) definitions required for SNMP-based monitoring of Enterasys Networks hardware system attributes, including device identity, software versions, and hardware inventory. It serves as the structural registry enabling network management systems to map and retrieve specific system-level metrics from Enterasys switches, routers, and wireless controllers.
The ENTERASYS-CLASS-OF-SERVICE-MIB manages transmission and reception attributes for Quality of Service (QoS) classification on Extreme Networks (formerly Enterasys) edge and access devices. It enables SNMP-based configuration and monitoring of traffic prioritization policies, including queue mapping, scheduling, and bandwidth allocation parameters.
The ENTERASYS-FIREWALL-MIB enables SNMP-based configuration, policy management, and real-time monitoring of Enterasys firewall appliances, specifically exposing metrics for access control rules, session states, and interface traffic statistics.
The ENTERASYS-LSNAT-MIB provides management access to Layer 4 Session NAT (LSNAT) entities on Enterasys Networks hardware, enabling the monitoring of active session states, translation table entries, and packet/byte counters for protocol-specific NAT mappings.
The ENTERASYS-POLICY-PROFILE-MIB enables SNMP-based monitoring and configuration of per-user policy profiles on Enterasys network edge and access devices. It facilitates the retrieval and management of specific user authentication and authorization parameters, including assigned access control lists and traffic shaping rules, to enforce granular network access policies.
The ENTERASYS-TWCB-MIB-2 module enables monitoring and management of Time-Weighted Cost-Based (TWCB) routing metrics and interface attributes on Enterasys Networks switches. It provides specific counters and gauges for tracking path costs and link states to support advanced traffic engineering and load balancing decisions.