Home/Catalog/DNS-340L-MIB

DNS-340L-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

42
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

42 total
Object Name
productID
OBJECT IDENTIFIER
.1.3.6.1.4.1.171.50
projectID
OBJECT IDENTIFIER
.1.3.6.1.4.1.171.50.1
modelID
OBJECT IDENTIFIER
.1.3.6.1.4.1.171.50.1.10
submodelID
OBJECT IDENTIFIER
.1.3.6.1.4.1.171.50.1.10.1
nasAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.171.50.1.10.1.1
dns340LAgentVerVersion information for the agent of SNMP of DNS-340L.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.1
dns340LSoftwareVersionThe device software version.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.2
dns340LHostNameThe device host name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.3
dns340LFTPServerFtp Server status. (Disable/Enable)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.5
dns340LNetTypeThe Network type. (Workgroup/Active Directory)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.6
dns340LTemperatureThe temperature of the system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.7
dns340LFanStatusThe status of the fanro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.8
dns340LVolumeTableA table of active volumes on the NAS device.
SEQUENCE OF Dns340LVolumeEntry
.1.3.6.1.4.1.171.50.1.10.1.1.9
dns340LVolumeEntryAn entry in the volume table.
Dns340LVolumeEntry
.1.3.6.1.4.1.171.50.1.10.1.1.9.1
dns340LVolumeNumInstance number of the volume entry.ro
Integer32
.1.3.6.1.4.1.171.50.1.10.1.1.9.1.1
dns340LVolumeNameThe name of the volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.9.1.2
dns340LVolumeFsTypeThe type of file system of the volume. Example : ext3 or ext4ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.9.1.3
dns340LVolumeRaidLevelThe RAID level of the volume. (STANDARD LINEAR RAID0 RAID1 RAID5 RAID10 RAID5+SPARE)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.9.1.4
dns340LVolumeSizeThe size of the volume in bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.9.1.5
dns340LVolumeFreeSpaceFree space on the volume in bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.9.1.6
dns340LDiskTableA table of physical disks attached to the NAS device.
SEQUENCE OF Dns340LDiskEntry
.1.3.6.1.4.1.171.50.1.10.1.1.10
dns340LDiskEntryAn entry in the physical disk table.
Dns340LDiskEntry
.1.3.6.1.4.1.171.50.1.10.1.1.10.1
dns340LDiskNumInstance number of the disk entry.ro
Integer32
.1.3.6.1.4.1.171.50.1.10.1.1.10.1.1
dns340LDiskVendorThe vendor of the disk drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.10.1.2
dns340LDiskModelThe disk drive's model name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.10.1.3
dns340LDiskSerialNumberThe disk drive's serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.10.1.4
dns340LDiskTemperatureThe centigrade temperature of this disk.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.10.1.5
dns340LDiskCapacityThe capacity of the disk in GB.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.10.1.6
dns340LUPSTableA table of UPS attached to the NAS device.
SEQUENCE OF Dns340LUPSEntry
.1.3.6.1.4.1.171.50.1.10.1.1.11
dns340LUPSEntryAn entry in the UPS table.
Dns340LUPSEntry
.1.3.6.1.4.1.171.50.1.10.1.1.11.1
dns340LUPSNumInstance number of the UPS entry.ro
Integer32
.1.3.6.1.4.1.171.50.1.10.1.1.11.1.1
dns340LUPSModeThe mode of the UPSro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.11.1.2
dns340LUPSManufacturerThe manufacturer of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.11.1.3
dns340LUPSProductThe product name of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.11.1.4
dns340LUPSBatteryChargeThe battery charge of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.11.1.5
dns340LUPSStatusThe status of this UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.171.50.1.10.1.1.11.1.6
notifyEvts
OBJECT IDENTIFIER
.1.3.6.1.4.1.171.50.1.10.1.1.200
notifyPasswdChangedAn indication that the Administrator's password has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.171.50.1.10.1.1.200.1
notifyFirmwareUpgradedAn indication that firmware has been upgraded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.171.50.1.10.1.1.200.2
notifyNetworkChangedAn indication that the network settings has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.171.50.1.10.1.1.200.3
notifyTemperatureExceededAn indication that system temperature has exceeded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.171.50.1.10.1.1.200.4
DNS-340L-MIB - SNMP MIB Reference | MIBs Explorer