DNS-340L-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
Imported Objects
Objects
42 total| Object Name |
|---|
d_link OBJECT IDENTIFIER .1.3.6.1.4.1.171 |
productID OBJECT IDENTIFIER .1.3.6.1.4.1.171.50 |
projectID OBJECT IDENTIFIER .1.3.6.1.4.1.171.50.1 |
modelID OBJECT IDENTIFIER .1.3.6.1.4.1.171.50.1.10 |
submodelID OBJECT IDENTIFIER .1.3.6.1.4.1.171.50.1.10.1 |
nasAgent OBJECT IDENTIFIER .1.3.6.1.4.1.171.50.1.10.1.1 |
dns340LAgentVerVersion information for the agent of SNMP of DNS-340L.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.1 |
dns340LSoftwareVersionThe device software version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.2 |
dns340LHostNameThe device host name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.3 |
dns340LFTPServerFtp Server status. (Disable/Enable)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.5 |
dns340LNetTypeThe Network type. (Workgroup/Active Directory)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.6 |
dns340LTemperatureThe temperature of the system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.7 |
dns340LFanStatusThe status of the fanro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.8 |
dns340LVolumeTableA table of active volumes on the NAS device. SEQUENCE OF Dns340LVolumeEntry .1.3.6.1.4.1.171.50.1.10.1.1.9 |
dns340LVolumeEntryAn entry in the volume table. Dns340LVolumeEntry .1.3.6.1.4.1.171.50.1.10.1.1.9.1 |
dns340LVolumeNumInstance number of the volume entry.ro Integer32 .1.3.6.1.4.1.171.50.1.10.1.1.9.1.1 |
dns340LVolumeNameThe name of the volume.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.9.1.2 |
dns340LVolumeFsTypeThe type of file system of the volume. Example : ext3 or ext4ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.9.1.3 |
dns340LVolumeRaidLevelThe RAID level of the volume. (STANDARD LINEAR RAID0 RAID1 RAID5 RAID10 RAID5+SPARE)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.9.1.4 |
dns340LVolumeSizeThe size of the volume in bytes.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.9.1.5 |
dns340LVolumeFreeSpaceFree space on the volume in bytes.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.9.1.6 |
dns340LDiskTableA table of physical disks attached to the NAS device. SEQUENCE OF Dns340LDiskEntry .1.3.6.1.4.1.171.50.1.10.1.1.10 |
dns340LDiskEntryAn entry in the physical disk table. Dns340LDiskEntry .1.3.6.1.4.1.171.50.1.10.1.1.10.1 |
dns340LDiskNumInstance number of the disk entry.ro Integer32 .1.3.6.1.4.1.171.50.1.10.1.1.10.1.1 |
dns340LDiskVendorThe vendor of the disk drive.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.10.1.2 |
dns340LDiskModelThe disk drive's model name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.10.1.3 |
dns340LDiskSerialNumberThe disk drive's serial number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.10.1.4 |
dns340LDiskTemperatureThe centigrade temperature of this disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.10.1.5 |
dns340LDiskCapacityThe capacity of the disk in GB.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.10.1.6 |
dns340LUPSTableA table of UPS attached to the NAS device. SEQUENCE OF Dns340LUPSEntry .1.3.6.1.4.1.171.50.1.10.1.1.11 |
dns340LUPSEntryAn entry in the UPS table. Dns340LUPSEntry .1.3.6.1.4.1.171.50.1.10.1.1.11.1 |
dns340LUPSNumInstance number of the UPS entry.ro Integer32 .1.3.6.1.4.1.171.50.1.10.1.1.11.1.1 |
dns340LUPSModeThe mode of the UPSro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.11.1.2 |
dns340LUPSManufacturerThe manufacturer of the UPS.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.11.1.3 |
dns340LUPSProductThe product name of the UPS.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.11.1.4 |
dns340LUPSBatteryChargeThe battery charge of the UPS.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.11.1.5 |
dns340LUPSStatusThe status of this UPS.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.50.1.10.1.1.11.1.6 |
notifyEvts OBJECT IDENTIFIER .1.3.6.1.4.1.171.50.1.10.1.1.200 |
notifyPasswdChangedAn indication that the Administrator's password has been changed. NOTIFICATION-TYPE .1.3.6.1.4.1.171.50.1.10.1.1.200.1 |
notifyFirmwareUpgradedAn indication that firmware has been upgraded. NOTIFICATION-TYPE .1.3.6.1.4.1.171.50.1.10.1.1.200.2 |
notifyNetworkChangedAn indication that the network settings has been changed. NOTIFICATION-TYPE .1.3.6.1.4.1.171.50.1.10.1.1.200.3 |
notifyTemperatureExceededAn indication that system temperature has exceeded. NOTIFICATION-TYPE .1.3.6.1.4.1.171.50.1.10.1.1.200.4 |
More MIBs from D-Link
Browse all D-LinkMIBs →SNMP MIB module
The DGS-1210-12TSME-BX MIB module provides management capabilities for the D-Link DES-1210-52ME switch, specifically enabling the monitoring and configuration of QinQ (802.1ad) VLAN encapsulation parameters, including inner tag insertion and drop counters for unmatched traffic. This module facilitates precise control over service provider bridging (SPB) operations by exposing metrics related to VLAN tag manipulation and packet discard events on the device's managed ports.