DMTF-MOBILE-MIB
This MIB is a translation of the DMTF Mobile Computer MIF, based on the translation rules defined by the DMTF DMI to SNMP Mapping Standard, Version 1.0. DMI-based systems running a DMI-to-SNMP Mapping Agent provide the ability to access DMI component instrumentation via SNMP protocol operations.
Main OID:
dmtfMobileComputerMIF.1.3.6.1.4.1.412.2.8
98
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
98 total| Object Name |
|---|
dmtf OBJECT IDENTIFIER .1.3.6.1.4.1.412 |
dmtfStdMifs OBJECT IDENTIFIER .1.3.6.1.4.1.412.2 |
dmtfMobileComputerMIFThis MIB is a translation of the DMTF Mobile Computer MIF, based on the translation rules defined by the DMTF DMI to SNMP Mapping Standard, Version 1.0. DMI-based systems running a DMI-to-SNMP Mapping Agent provide the ability to access DMI component instrumentation via SNMP protocol operations. MODULE-IDENTITY .1.3.6.1.4.1.412.2.8 |
dmtfPortableBatteryTableThis group defines general information about the portable battery(s) in the system SEQUENCE OF SdmtfPortableBattery .1.3.6.1.4.1.412.2.8.1 |
dmtfPortableBatteryTraps OBJECT IDENTIFIER .1.3.6.1.4.1.412.2.8.1.0 |
dmtfPortableBatteryLowCombinedBatterysChargeThe combined charge of all batteries in the portable computer is running low. NOTIFICATION-TYPE .1.3.6.1.4.1.412.2.8.1.0.1 |
dmtfPortableBatteryCriticalCombinedBatterysChargeThe combined charge of all batteries in the portable computer is critcally low. NOTIFICATION-TYPE .1.3.6.1.4.1.412.2.8.1.0.2 |
dmtfPortableBatteryMaintenanceRequiredA battery in the portable computer is defective and requires maintenance. NOTIFICATION-TYPE .1.3.6.1.4.1.412.2.8.1.0.3 |
dmtfPortableBatteryEntryThis group defines general information about the portable battery(s) in the system SdmtfPortableBattery .1.3.6.1.4.1.412.2.8.1.1 |
dmtfPortableBatteryStaterw Enumeration .1.3.6.1.4.1.412.2.8.1.1.0 |
portableBatteryIndexThe index into the portable battery table.ro DmiInteger .1.3.6.1.4.1.412.2.8.1.1.1 |
portableBatteryLocationThe location of the batteryro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.1.1.2 |
portableBatteryManufacturerThe name of the company that manufactured the battery.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.1.1.3 |
portableBatteryManufactureDateThe battery manufacture date.ro Dmi-Date .1.3.6.1.4.1.412.2.8.1.1.4 |
portableBatterySerialNumberThe serial number for this battery.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.1.1.5 |
portableBatteryDeviceNameDevice name for this battery. For instance, Duracell DR-36.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.1.1.6 |
portableBatteryDeviceChemistryThe battery chemistry. For instance, Lithium-ion or Nickel metal hydride.ro Enumeration .1.3.6.1.4.1.412.2.8.1.1.7 |
portableBatteryDesignCapacityThe design capacity of the battery in mWatt-hours. If this attribute is not supported, value = 0x80000000ro DmiInteger .1.3.6.1.4.1.412.2.8.1.1.8 |
portableBatteryDesignVoltageThe design voltage of the battery in mVolts. If this attribute is not supported, value = 0x80000000ro DmiInteger .1.3.6.1.4.1.412.2.8.1.1.9 |
smartBatteryVersionThe Smart Battery Data Specification version number supported by this battery. If the battery does not support this function, the value should be left blank.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.1.1.10 |
fullChargeCapacityThe full charge capacity of the battery in mWatt-hours. Comparis n of this value to the battery Design Capacity determines when the battery requires replacement. The battery industry has defined a battery's end of life to be when the Full Charge Capacity falls below 80% of the Design Capacity. If this attribute is not supported, value = -1.ro DmiInteger .1.3.6.1.4.1.412.2.8.1.1.11 |
remainingCapacityThe battery's remaining capacity in mWatt-hours. This value is used with Design Capacity or Full Charge Capacity to calculate fuel gauge information. If this attribute is not supported, value = -1.ro DmiInteger .1.3.6.1.4.1.412.2.8.1.1.12 |
maximumErrorThe maximum error (as a percentage) in the Watt-hour data reported by the battery. The maximum error indicates the upper bound on how much additional energy the battery may have above the energy it reports having. When this value exceeds some value, for instance, 10%, some action must be taken (for instance, fully discharge then fully charge the battery) within some specified time (for instance, within two recharge cycles of the battery). If the action is not taken within the time frame, the error valuero DmiInteger .1.3.6.1.4.1.412.2.8.1.1.13 |
portableBatteryChargingStatusThe charging battery statusro Enumeration .1.3.6.1.4.1.412.2.8.1.1.14 |
remainingBatteryTimeThe remaining battery time in minutes, at the current average system power consumption level.ro DmiInteger .1.3.6.1.4.1.412.2.8.1.1.15 |
remainingTimeToFullBatteryThe remaining time to charge the battery fully in minutes,at the current average system power consumption level and charging ratero DmiInteger .1.3.6.1.4.1.412.2.8.1.1.16 |
powerUnitIndexThis is the ID of the Power Unit (logical portable battery) to which this Portable Battery belongs. This value matches up with the Power Unit Table Index attribute defined in the Power Unit Global Table.ro DmiInteger .1.3.6.1.4.1.412.2.8.1.1.17 |
dmtfPortableBatteryEvSysThe major functional aspect of the product causing the fault. Enumeration .1.3.6.1.4.1.412.2.8.1.6 |
dmtfPortableBatteryEvSubThe minor functional aspect of the product causing the fault. Enumeration .1.3.6.1.4.1.412.2.8.1.7 |
dmtfDynamicStatesTableThis group defines the dynamic states information in the portable system SEQUENCE OF SdmtfDynamicStates .1.3.6.1.4.1.412.2.8.2 |
dmtfDynamicStatesEntryThis group defines the dynamic states information in the portable system SdmtfDynamicStates .1.3.6.1.4.1.412.2.8.2.1 |
aCLineStatusThis group defines status information about the AC line in the notebookro Enumeration .1.3.6.1.4.1.412.2.8.2.1.1 |
dockingStatusDefines whether system is docked or notro Enumeration .1.3.6.1.4.1.412.2.8.2.1.2 |
dmtfVideoOutputDeviceTableThis group defines the attributes for video output devices SEQUENCE OF SdmtfVideoOutputDevice .1.3.6.1.4.1.412.2.8.3 |
dmtfVideoOutputDeviceEntryThis group defines the attributes for video output devices SdmtfVideoOutputDevice .1.3.6.1.4.1.412.2.8.3.1 |
dmtfVideoOutputDeviceStaterw Enumeration .1.3.6.1.4.1.412.2.8.3.1.0 |
index2Defines the index into the video output groupro DmiInteger .1.3.6.1.4.1.412.2.8.3.1.1 |
builtInDefines whether the video output device is built inro Enumeration .1.3.6.1.4.1.412.2.8.3.1.2 |
type2Defines the type of the video output devicero Enumeration .1.3.6.1.4.1.412.2.8.3.1.3 |
colorSupportDefines whether the video output device supports colorro Enumeration .1.3.6.1.4.1.412.2.8.3.1.4 |
brightnessThe percentage (0-100) of total brightness of the video output device. If feature not available, value = 0x80000000ro DmiInteger .1.3.6.1.4.1.412.2.8.3.1.5 |
contrastThe percentage (0-100) of total contrast of the videooutput device. If feature not available, value = 0x80000000ro DmiInteger .1.3.6.1.4.1.412.2.8.3.1.6 |
videoGroupReferenceDefines the reference into the video groupro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.3.1.7 |
dmtfInfraredPortTableThis group defines attributes for Infrared Ports SEQUENCE OF SdmtfInfraredPort .1.3.6.1.4.1.412.2.8.4 |
dmtfInfraredPortEntryThis group defines attributes for Infrared Ports SdmtfInfraredPort .1.3.6.1.4.1.412.2.8.4.1 |
dmtfInfraredPortStaterw Enumeration .1.3.6.1.4.1.412.2.8.4.1.0 |
iRIndexIndex to identify the IR portro DmiInteger .1.3.6.1.4.1.412.2.8.4.1.1 |
iRLocationLocation of the IR window on the devicero DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.4.1.2 |
iREnableStateDefines whether IR is enabled or disabledro Enumeration .1.3.6.1.4.1.412.2.8.4.1.3 |
iRLimitSpeedEnableDefines whether IR speed is limited or not.ro Enumeration .1.3.6.1.4.1.412.2.8.4.1.4 |
iRSpeedLimitDefines connection speed limit of the IR port, in bits per second.ro DmiInteger .1.3.6.1.4.1.412.2.8.4.1.5 |
iRPhysicalPortNameDefines the physical port that IR is connected to.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.4.1.6 |
iRVirtualCOMPortNameDefines the virtual COM port the IR is connected to.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.4.1.7 |
iRVirtualLPTPortNameDefines the virtual LPT port the IR is connected to.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.4.1.8 |
iRProtocolDefines protocol used to establish the IR connectionro Enumeration .1.3.6.1.4.1.412.2.8.4.1.9 |
dmtfPointingDeviceTableThis group defines the characteristics of a pointing device. SEQUENCE OF SdmtfPointingDevice .1.3.6.1.4.1.412.2.8.5 |
dmtfPointingDeviceEntryThis group defines the characteristics of a pointing device. SdmtfPointingDevice .1.3.6.1.4.1.412.2.8.5.1 |
pointingDeviceTypeThe type of this Pointing Device.ro Enumeration .1.3.6.1.4.1.412.2.8.5.1.1 |
pointingDeviceInterfaceThe interface type of this Pointing Device.ro Enumeration .1.3.6.1.4.1.412.2.8.5.1.2 |
pointingDeviceIRQThe IRQ number used by this Pointing Device.ro DmiInteger .1.3.6.1.4.1.412.2.8.5.1.3 |
pointingDeviceButtonsThe number of Pointing Device buttons on this Pointing Device.ro DmiInteger .1.3.6.1.4.1.412.2.8.5.1.4 |
pointingDevicePortNameThe name of the port currently being used by this Pointing Device.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.5.1.5 |
pointingDeviceDriverNameThe name of the Pointing Device driver.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.5.1.6 |
pointingDeviceDriverVersionThe version number of the Pointing Device driver.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.5.1.7 |
fRUGroupIndexIf this is a Field Replaceable Unit or if it is part of another FRU, this provides an index into the FRU table; 'value = -1' indicates that the group is not a FRU.ro DmiInteger .1.3.6.1.4.1.412.2.8.5.1.8 |
operationalGroupIndexThe index into the Operational State table for this device.ro DmiInteger .1.3.6.1.4.1.412.2.8.5.1.9 |
securitySettingsEnum describing the current hardware security settings on this device.ro Enumeration .1.3.6.1.4.1.412.2.8.5.1.10 |
dmtfSystemPowerManagementTableThis group defines system power management attributes SEQUENCE OF SdmtfSystemPowerManagement .1.3.6.1.4.1.412.2.8.6 |
dmtfSystemPowerManagementEntryThis group defines system power management attributes SdmtfSystemPowerManagement .1.3.6.1.4.1.412.2.8.6.1 |
powerManagementCapabilitiesDefines what type of Power Management this system supports (i.e APM 1.2, ACPI 1.0)ro Enumeration .1.3.6.1.4.1.412.2.8.6.1.1 |
reducedCPUClockSpeedDefines whether to enable CPU to slow down when possiblero Enumeration .1.3.6.1.4.1.412.2.8.6.1.2 |
overrideACEnables/Disables power savings when AC is connectedro Enumeration .1.3.6.1.4.1.412.2.8.6.1.3 |
ringEventResumeEnables system to resume operation when a modem ring occurs on a serial port or a wakeup occurs on a PC Cardro Enumeration .1.3.6.1.4.1.412.2.8.6.1.4 |
alarmResumeEnables system to resume operation from suspend/standby mode at a time determined by an application program.ro Enumeration .1.3.6.1.4.1.412.2.8.6.1.5 |
dmtfPowerManagementTableThis group defines the power management state of components and groups within the system SEQUENCE OF SdmtfPowerManagementTable .1.3.6.1.4.1.412.2.8.7 |
dmtfPowerManagementEntryThis group defines the power management state of components and groups within the system SdmtfPowerManagementTable .1.3.6.1.4.1.412.2.8.7.1 |
dmtfPowerManagementTableStaterw Enumeration .1.3.6.1.4.1.412.2.8.7.1.0 |
powerManagementEnabledDisabledEnabled/Disabled state of power management on this device.ro Enumeration .1.3.6.1.4.1.412.2.8.7.1.1 |
currentPowerManagementStateThe current PM state (D0,D1,D2,D3).ro Enumeration .1.3.6.1.4.1.412.2.8.7.1.2 |
d1TimerValueThe time-out value in milliseconds to go from D0 (full ON) to D1 state. If D1 state is not supported the value is -1. If the transition is not controlled by a timer then the value is 0.ro DmiInteger .1.3.6.1.4.1.412.2.8.7.1.3 |
d2TimerValueThe time-out value in milliseconds to go from the next higher supported state (either D0 or D1) to the D2 state. If D2 state is not supporte the value is -1. If the transition is not controlled by a timer then the value is 0.ro DmiInteger .1.3.6.1.4.1.412.2.8.7.1.4 |
d3TimerValueThe time-out value in milliseconds to go from the next higher supported state (either D0, D1, or D2) to the D3 state. If D3 state is not supported the value is -1 meaning the device can never be turned off. If the transition is not controlled by a timer then the value is 0.ro DmiInteger .1.3.6.1.4.1.412.2.8.7.1.5 |
dmtfPowerManagementBinaryAssociationTable SEQUENCE OF SdmtfPowerManagementBinaryAssociationTable .1.3.6.1.4.1.412.2.8.8 |
dmtfPowerManagementBinaryAssociationEntry SdmtfPowerManagementBinaryAssociationTable .1.3.6.1.4.1.412.2.8.8.1 |
dmtfPowerManagementBinaryAssociationTableStaterw Enumeration .1.3.6.1.4.1.412.2.8.8.1.0 |
indexro DmiInteger .1.3.6.1.4.1.412.2.8.8.1.1 |
typero DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.8.1.2 |
ref1ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.8.1.3 |
ref2ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.8.1.4 |
dmtfDeviceBayTableThis group defines device bays characteristics SEQUENCE OF SdmtfDeviceBay .1.3.6.1.4.1.412.2.8.9 |
dmtfDeviceBayEntryThis group defines device bays characteristics SdmtfDeviceBay .1.3.6.1.4.1.412.2.8.9.1 |
dmtfDeviceBayStaterw Enumeration .1.3.6.1.4.1.412.2.8.9.1.0 |
deviceBayIndexDefines an index for the device bays in the systemro DmiInteger .1.3.6.1.4.1.412.2.8.9.1.1 |
deviceBayTypeDefines the type of Device Bay. Examples of Proprietary Bay are: Swappable Bay, Multi-Function Bay and Media Bay Typesro Enumeration .1.3.6.1.4.1.412.2.8.9.1.2 |
deviceBayLocationDefines the physical location of the device bayro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.9.1.3 |
devicesSupportedDefines a string containing a list of devices supported in this bay separated by commas.ro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.9.1.4 |
deviceCurrentlyAttachedDefines the name of the device currently attached to this bayro DmiString (DMTF-DMI-MIB) .1.3.6.1.4.1.412.2.8.9.1.5 |
dmtfDynOids OBJECT IDENTIFIER .1.3.6.1.4.1.412.3 |