DLGDS1-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for DLGDS1-MIB.
12
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
12 total| Object Name |
|---|
dlgDs1 OBJECT IDENTIFIER .1.3.6.1.4.1.3028.3.1.1 |
dlgDsx1ConfigTableThe DS1 Configuration table. This table is a list of entries Containing
configuration information for all the digital interfaces managed by this
system SEQUENCE OF DlgDsx1ConfigEntry .1.3.6.1.4.1.3028.3.1.1.6 |
dlgDsx1ConfigEntryAn entry containing configuration information for all the digital interfaces
managed by this system. DlgDsx1ConfigEntry .1.3.6.1.4.1.3028.3.1.1.6.1 |
dlgDsx1LineIndexThis object is the unique identifier of a Digital Network Interface on a
managed device, the unique identifier is the Dialogic Digital Front End (DTI)ro INTEGER (1..'7fffffff'h) .1.3.6.1.4.1.3028.3.1.1.6.1.1 |
dlgDsx1HiIdentIndexThis OID provides a way to identify the Dialogic board that hosts the interface
referenced in the DS1 configuration table entry. The value of this object is
equivalent to the value of the dlgHiIdentIndex that references the board in
which the interface resides (dlgHiIdentIndex is in the dlghwinf MIB).
For example, to identify the board hosting the network interface that
generated an alarm, retrieve the value of this OID for the interface in
question and then insert this value in the dlgHiIdentIndex OID in the
dlghwinf MIB; the board corresponding to the dlgHiIdentIndex value is the one on
which the network interface that generated the alarm residesro INTEGER (1..'7fffffff'h) .1.3.6.1.4.1.3028.3.1.1.6.1.2 |
dlgDsx1TimeElapsedThe number of seconds that have elapsed since the beginning of the current
error-measurement period .The length of the current error-measurement period
will be 15 Minutes ( 900 seconds)ro INTEGER .1.3.6.1.4.1.3028.3.1.1.6.1.3 |
dlgDsx1ValidIntervalsThe number of previous intervals for which valid data was collected.
The value will be 96 unless the interface was brought on-line within the last
24 hours, in which case the value will be the number of complete 15-minute
intervals, since interface has been online. 'On-line' means both the SNMP and
the Dialogic service are on that particular Interface to provide valid dataro INTEGER .1.3.6.1.4.1.3028.3.1.1.6.1.4 |
dlgDsx1LineTypeThis variable indicates the variety of DS1 Line implementing this circuit.
The type of circuit affects the number of bits per second that the circuit can
reasonably carry, as well as the interpretation of the usage
and error statistics.
1- other
2 - dlgDsx1D4
3 - dlgDsx1E1-CRC
Telephony Recommendation G.704 (Table 4b)ro Enumeration .1.3.6.1.4.1.3028.3.1.1.6.1.5 |
dlgDsx1LineCodingThis variable describes the variety of Zero Code Suppression used on the link,
which in turn affects a number of its characteristics.
1 - dlgDsx1JBZS->refers to the Jammed Bit Zero Suppression, in which
the AT&T specification of at least one pulse every 8 bit periods is literally
implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits
per channel, or 1.344 Mbps, is available for data.
2 - dlgDsx1B8ZS->refers to the use of a specified pattern of normal
bits and bipolar violations which are used to replace a sequence of eight zero
bits.
3 - dlgDsx1InvertedHDLC->refers to a mode wherein no zero code suppression is
present and the line encoding does not solve the problem directly. In this
application, the higher layer provides data that meets or exceeds the
pulse density requirements, such as inverting High level Data Link Control data.
4 - dlgDsx1TRAN >refers to transparent code suppression, which means
that no code suppression is presentrw Enumeration .1.3.6.1.4.1.3028.3.1.1.6.1.6 |
dlgDsx1SendCodeThe springware boards of dialogic are not capable of sending any code, where
as the DM3 family of dialogic boards mightro Enumeration .1.3.6.1.4.1.3028.3.1.1.6.1.7 |
dlgDsx1CircuitIdentifierThis OID enables you to specify a string by which to identify the trunk
connected to the interface referenced in the DS1 configuration table entry.
For example, the two interfaces on a D/240SC-2T1 might be connected to trunks
supplied by two different vendors; this OID can be set to the name of the vendor
supplying the trunk. This OID's default value is 'Dialogic'.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3028.3.1.1.6.1.8 |
dlgDsx1LoopbackConfigThis variable represents the loop back configuration of the Digital
Network interface. The values mean:
1 - dlgDsx1Normal
Interface Remote loop back test switch is turned off.
2 - dlgDsx1PayloadLoop
through the device. Typically the received signal is looped back for
retransmission after it has passed through the device's framing function.
This mode is used for the Digital Network Interface testing .
3 - dlgDsx1LineLoop->The received signal at this interface does not go
through the device (minimum penetration) but is looped back out. This loop
back is generally used by the network for network testing .
4 - dlgDsx1localLoop>The line interface unit is in local
loop back mode ( used generally for Digital Network Interface testingrw Enumeration .1.3.6.1.4.1.3028.3.1.1.6.1.9 |