Home/Catalog/DGS-6600-EQUIPMENT-MIB

DGS-6600-EQUIPMENT-MIB

The structure of chassis HW function for the proprietary enterprise.
Main OID:
dgs6600EquipmentMIB.dgs6600-system.2
64
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

64 total
Object Name
dgs6600EquipmentMIBThe structure of chassis HW function for the proprietary enterprise.
MODULE-IDENTITY
.dgs6600-system.2
chassisControlModuleLEDInfo
OBJECT IDENTIFIER
.dgs6600-system.2.1
chassisControlModuleLEDInfoTableTBD.
SEQUENCE OF ChassisControlModuleLEDInfoEntry
.dgs6600-system.2.1.1
chassisControlModuleLEDInfoEntryTBD.
ChassisControlModuleLEDInfoEntry
.dgs6600-system.2.1.1.1
chassisControlModuleLEDInfoIndexThis object indicates the slot index of Control Module.ro
INTEGER
.dgs6600-system.2.1.1.1.1
chassisControlModuleLEDInfoConsoleThis object indicates the console type. There are two different interfaces: 1: RS232. 2: USB.ro
Enumeration
.dgs6600-system.2.1.1.1.2
chassisControlModuleLEDInfoMasterThis object indicates whether this control module is master or not? 1: This control module is active CM. 2: This control module is standby CM.ro
Enumeration
.dgs6600-system.2.1.1.1.3
chassisControlModuleLEDInfoCPUUtilizationThis object indicates the CPU utilization(in percentage) of this control module.ro
Enumeration
.dgs6600-system.2.1.1.1.4
chassisControlModuleLEDInfoMgmtPortStatusThis object indicates the management port status.ro
Enumeration
.dgs6600-system.2.1.1.1.5
chassisControlModuleLEDInfoMgmtPortSpeedThis object indicates the management port link speed.ro
Enumeration
.dgs6600-system.2.1.1.1.6
chassisPowerInfo
OBJECT IDENTIFIER
.dgs6600-system.2.2
chassisPowerInfoTableTBD.
SEQUENCE OF ChassisPowerInfoEntry
.dgs6600-system.2.2.1
chassisPowerInfoEntryTBD.
ChassisPowerInfoEntry
.dgs6600-system.2.2.1.1
chassisPowerIndexThis object indicates the PSU index.ro
INTEGER
.dgs6600-system.2.2.1.1.1
chassisPowerExistThis object indicates whether the specified PSU is exist or not. 1: The PSU is not exist. 2: The PSU is installed.ro
Enumeration
.dgs6600-system.2.2.1.1.2
chassisPowerTypeThis object indicates the PSU type. 1: The PSU type is AC. 2: The PSU type is DC. 3: The PSU type is unknown.ro
Enumeration
.dgs6600-system.2.2.1.1.3
chassisPowerAliveThis object indicates whether the specified PSU is alive or not. 1: The PSU is not available. 2: The PSU is working normally.ro
Enumeration
.dgs6600-system.2.2.1.1.4
chassisPowerVoltageThis object indicates the output voltage(V) of the specified PSU.ro
INTEGER
.dgs6600-system.2.2.1.1.5
chassisPowerCurrentThis object indicates the output current(mA) of the specified PSU.ro
INTEGER
.dgs6600-system.2.2.1.1.6
chassisPowerPowerWattThis object indicates the output power(W) of the specified PSU.ro
INTEGER
.dgs6600-system.2.2.1.1.7
chassisPowerFanSpeedThis object indicates the internal fan speed(rpm) of specified PSU.ro
INTEGER
.dgs6600-system.2.2.1.1.8
chassisFanTrayInfo
OBJECT IDENTIFIER
.dgs6600-system.2.3
chassisFanTrayInfoStateThis object indicates the fan tray state. There are three different state: 1. Not existed 2. Existed but failed 3. Working normallyro
Enumeration
.dgs6600-system.2.3.1
chassisFanInfoTableTBD.
SEQUENCE OF ChassisFanInfoEntry
.dgs6600-system.2.3.2
chassisFanInfoEntryTBD.
ChassisFanInfoEntry
.dgs6600-system.2.3.2.1
chassisFanIndexThis object indicates the fan tray index.ro
INTEGER
.dgs6600-system.2.3.2.1.1
chassisFanStatusThis object indicates the fan status(ok or failed).ro
Enumeration
.dgs6600-system.2.3.2.1.2
chassisFanSpeedThis object indicates the fan speed in RPM.ro
INTEGER
.dgs6600-system.2.3.2.1.3
chassisSlotInfo
OBJECT IDENTIFIER
.dgs6600-system.2.4
chassisSlotInfoTableTBD.
SEQUENCE OF ChassisSlotInfoEntry
.dgs6600-system.2.4.1
chassisSlotInfoEntryTBD.
ChassisSlotInfoEntry
.dgs6600-system.2.4.1.1
chassisSlotIndexThis object indicates the slot index.ro
INTEGER
.dgs6600-system.2.4.1.1.1
chassisSlotStateThis object indicates the slot state: 1: The slot has no card installed. 2: The card which installed at this slot is not powered up. 3: The card which installed at this slot is failed. 4: The card which installed at this slot is booting up. 5: The card is powered up.ro
Enumeration
.dgs6600-system.2.4.1.1.2
chassisSlotLEDPoEModeEnabledThis object indicates whether the PoE mode is enabled or not?ro
Enumeration
.dgs6600-system.2.4.1.1.3
chassisSlotModelThis object indicates the card model name.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.4.1.1.4
chassisSlotSerialNumberThis object indicates the serial number of the installed card.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.4.1.1.5
chassisSlotHwVersionThis object indicates the HW version of the installed card.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.4.1.1.6
chassisSlotPCBAVersionThis object indicates the PCBA version of the installed card.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.4.1.1.7
chassisSlotBootloaderVersionThis object indicates the PCBA version of the installed card.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.4.1.1.8
chassisSlotRuntimeVersionThis object indicates the runtime version of the installed card.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.4.1.1.9
chassisSlotCPLDVersionThis object indicates the CPLD version of the installed card.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.4.1.1.10
chassisSlotFirsMacAddressThis object indicates the first MAC address of the installed card.ro
MacAddress (SNMPv2-TC)
.dgs6600-system.2.4.1.1.11
chassisSlotNumberOfMacAddressThis object indicates the number of MAC address of the installed card.ro
INTEGER
.dgs6600-system.2.4.1.1.12
chassisTemperatureInfo
OBJECT IDENTIFIER
.dgs6600-system.2.5
chassisTemperatureInfoTableTBD.
SEQUENCE OF ChassisTemperatureInfoEntry
.dgs6600-system.2.5.1
chassisTemperatureInfoEntryTBD.
ChassisTemperatureInfoEntry
.dgs6600-system.2.5.1.1
chassisTemperatureSlotIndexThis object indicates the slot number which is currently querying.ro
INTEGER
.dgs6600-system.2.5.1.1.1
chassisTemperatureInletCurrentThis object displays the current temperature of Inlet sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.2
chassisTemperatureInletOverheatThis object displays the overheat threshold of Inlet sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.3
chassisTemperatureInletHeatdownThis object displays the heatdown threshold of Inlet sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.4
chassisTemperatureCenterCurrentThis object displays the current temperature of Center sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.5
chassisTemperatureCenterOverheatThis object displays the overheat threshold of Center sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.6
chassisTemperatureCenterHeatdownThis object displays the heatdown threshold of Center sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.7
chassisTemperatureOutletCurrentThis object displays the current temperature of Outlet sensor. The string N/A will be displayed to indicate that the card has no this sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.8
chassisTemperatureOutletOverheatThis object displays the overheat threshold of Outlet sensor. The string N/A will be displayed to indicate that the card has no this sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.9
chassisTemperatureOutletHeatdownThis object displays the outlet threshold of Outlet sensor. The string N/A will be displayed to indicate that the card has no this sensor.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.5.1.1.10
chassisPortLEDInfo
OBJECT IDENTIFIER
.dgs6600-system.2.6
chassisPortLEDInfoTableTBD.
SEQUENCE OF ChassisPortLEDInfoEntry
.dgs6600-system.2.6.1
chassisPortLEDInfoEntryTBD.
ChassisPortLEDInfoEntry
.dgs6600-system.2.6.1.1
chassisPortLEDIFIndexThis object indicates the interface index.ro
Integer32
.dgs6600-system.2.6.1.1.1
chassisPortLEDIFNameThis object indicates the interface name.ro
DisplayString (SNMPv2-TC)
.dgs6600-system.2.6.1.1.2
chassisPortLEDStatusThis object indicates the port LED status: 1: The port LED status of the interface index is off. 2: The port LED status of the interface index is steady-amber. 3: The port LED status of the interface index is steady-green. 4: The port LED status of the interface index is blinking-amber. 5: The port LED status of the interface index is blinking-green.ro
Enumeration
.dgs6600-system.2.6.1.1.3
chassisPortLEDModeThis object indicates the port LED mode: 1: The port LED is in Ethernet mode. 2: The poer LED is in PoE mode.ro
Enumeration
.dgs6600-system.2.6.1.1.4
chassisPortLEDMediumTypeThis object indicates the port LED medium type: 1: The medium type of port LED is copper. 2: The medium type of port LED is fiber.ro
Enumeration
.dgs6600-system.2.6.1.1.5