DGS-6600-EQUIPMENT-MIB
The structure of chassis HW function for the proprietary enterprise.
Main OID:
dgs6600EquipmentMIB.dgs6600-system.2
64
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
64 total| Object Name |
|---|
dgs6600EquipmentMIBThe structure of chassis HW function for the
proprietary enterprise. MODULE-IDENTITY .dgs6600-system.2 |
chassisControlModuleLEDInfo OBJECT IDENTIFIER .dgs6600-system.2.1 |
chassisControlModuleLEDInfoTableTBD. SEQUENCE OF ChassisControlModuleLEDInfoEntry .dgs6600-system.2.1.1 |
chassisControlModuleLEDInfoEntryTBD. ChassisControlModuleLEDInfoEntry .dgs6600-system.2.1.1.1 |
chassisControlModuleLEDInfoIndexThis object indicates the slot index of Control Module.ro INTEGER .dgs6600-system.2.1.1.1.1 |
chassisControlModuleLEDInfoConsoleThis object indicates the console type. There are two different interfaces:
1: RS232.
2: USB.ro Enumeration .dgs6600-system.2.1.1.1.2 |
chassisControlModuleLEDInfoMasterThis object indicates whether this control module is master or not?
1: This control module is active CM.
2: This control module is standby CM.ro Enumeration .dgs6600-system.2.1.1.1.3 |
chassisControlModuleLEDInfoCPUUtilizationThis object indicates the CPU utilization(in percentage) of this control module.ro Enumeration .dgs6600-system.2.1.1.1.4 |
chassisControlModuleLEDInfoMgmtPortStatusThis object indicates the management port status.ro Enumeration .dgs6600-system.2.1.1.1.5 |
chassisControlModuleLEDInfoMgmtPortSpeedThis object indicates the management port link speed.ro Enumeration .dgs6600-system.2.1.1.1.6 |
chassisPowerInfo OBJECT IDENTIFIER .dgs6600-system.2.2 |
chassisPowerInfoTableTBD. SEQUENCE OF ChassisPowerInfoEntry .dgs6600-system.2.2.1 |
chassisPowerInfoEntryTBD. ChassisPowerInfoEntry .dgs6600-system.2.2.1.1 |
chassisPowerIndexThis object indicates the PSU index.ro INTEGER .dgs6600-system.2.2.1.1.1 |
chassisPowerExistThis object indicates whether the specified PSU is exist or not.
1: The PSU is not exist.
2: The PSU is installed.ro Enumeration .dgs6600-system.2.2.1.1.2 |
chassisPowerTypeThis object indicates the PSU type.
1: The PSU type is AC.
2: The PSU type is DC.
3: The PSU type is unknown.ro Enumeration .dgs6600-system.2.2.1.1.3 |
chassisPowerAliveThis object indicates whether the specified PSU is alive or not.
1: The PSU is not available.
2: The PSU is working normally.ro Enumeration .dgs6600-system.2.2.1.1.4 |
chassisPowerVoltageThis object indicates the output voltage(V) of the specified PSU.ro INTEGER .dgs6600-system.2.2.1.1.5 |
chassisPowerCurrentThis object indicates the output current(mA) of the specified PSU.ro INTEGER .dgs6600-system.2.2.1.1.6 |
chassisPowerPowerWattThis object indicates the output power(W) of the specified PSU.ro INTEGER .dgs6600-system.2.2.1.1.7 |
chassisPowerFanSpeedThis object indicates the internal fan speed(rpm) of specified PSU.ro INTEGER .dgs6600-system.2.2.1.1.8 |
chassisFanTrayInfo OBJECT IDENTIFIER .dgs6600-system.2.3 |
chassisFanTrayInfoStateThis object indicates the fan tray state. There are three different state:
1. Not existed
2. Existed but failed
3. Working normallyro Enumeration .dgs6600-system.2.3.1 |
chassisFanInfoTableTBD. SEQUENCE OF ChassisFanInfoEntry .dgs6600-system.2.3.2 |
chassisFanInfoEntryTBD. ChassisFanInfoEntry .dgs6600-system.2.3.2.1 |
chassisFanIndexThis object indicates the fan tray index.ro INTEGER .dgs6600-system.2.3.2.1.1 |
chassisFanStatusThis object indicates the fan status(ok or failed).ro Enumeration .dgs6600-system.2.3.2.1.2 |
chassisFanSpeedThis object indicates the fan speed in RPM.ro INTEGER .dgs6600-system.2.3.2.1.3 |
chassisSlotInfo OBJECT IDENTIFIER .dgs6600-system.2.4 |
chassisSlotInfoTableTBD. SEQUENCE OF ChassisSlotInfoEntry .dgs6600-system.2.4.1 |
chassisSlotInfoEntryTBD. ChassisSlotInfoEntry .dgs6600-system.2.4.1.1 |
chassisSlotIndexThis object indicates the slot index.ro INTEGER .dgs6600-system.2.4.1.1.1 |
chassisSlotStateThis object indicates the slot state:
1: The slot has no card installed.
2: The card which installed at this slot is not powered up.
3: The card which installed at this slot is failed.
4: The card which installed at this slot is booting up.
5: The card is powered up.ro Enumeration .dgs6600-system.2.4.1.1.2 |
chassisSlotLEDPoEModeEnabledThis object indicates whether the PoE mode is enabled or not?ro Enumeration .dgs6600-system.2.4.1.1.3 |
chassisSlotModelThis object indicates the card model name.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.4.1.1.4 |
chassisSlotSerialNumberThis object indicates the serial number of the installed card.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.4.1.1.5 |
chassisSlotHwVersionThis object indicates the HW version of the installed card.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.4.1.1.6 |
chassisSlotPCBAVersionThis object indicates the PCBA version of the installed card.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.4.1.1.7 |
chassisSlotBootloaderVersionThis object indicates the PCBA version of the installed card.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.4.1.1.8 |
chassisSlotRuntimeVersionThis object indicates the runtime version of the installed card.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.4.1.1.9 |
chassisSlotCPLDVersionThis object indicates the CPLD version of the installed card.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.4.1.1.10 |
chassisSlotFirsMacAddressThis object indicates the first MAC address of the installed card.ro MacAddress (SNMPv2-TC) .dgs6600-system.2.4.1.1.11 |
chassisSlotNumberOfMacAddressThis object indicates the number of MAC address of the installed card.ro INTEGER .dgs6600-system.2.4.1.1.12 |
chassisTemperatureInfo OBJECT IDENTIFIER .dgs6600-system.2.5 |
chassisTemperatureInfoTableTBD. SEQUENCE OF ChassisTemperatureInfoEntry .dgs6600-system.2.5.1 |
chassisTemperatureInfoEntryTBD. ChassisTemperatureInfoEntry .dgs6600-system.2.5.1.1 |
chassisTemperatureSlotIndexThis object indicates the slot number which is currently querying.ro INTEGER .dgs6600-system.2.5.1.1.1 |
chassisTemperatureInletCurrentThis object displays the current temperature of Inlet sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.2 |
chassisTemperatureInletOverheatThis object displays the overheat threshold of Inlet sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.3 |
chassisTemperatureInletHeatdownThis object displays the heatdown threshold of Inlet sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.4 |
chassisTemperatureCenterCurrentThis object displays the current temperature of Center sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.5 |
chassisTemperatureCenterOverheatThis object displays the overheat threshold of Center sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.6 |
chassisTemperatureCenterHeatdownThis object displays the heatdown threshold of Center sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.7 |
chassisTemperatureOutletCurrentThis object displays the current temperature of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.8 |
chassisTemperatureOutletOverheatThis object displays the overheat threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.9 |
chassisTemperatureOutletHeatdownThis object displays the outlet threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.5.1.1.10 |
chassisPortLEDInfo OBJECT IDENTIFIER .dgs6600-system.2.6 |
chassisPortLEDInfoTableTBD. SEQUENCE OF ChassisPortLEDInfoEntry .dgs6600-system.2.6.1 |
chassisPortLEDInfoEntryTBD. ChassisPortLEDInfoEntry .dgs6600-system.2.6.1.1 |
chassisPortLEDIFIndexThis object indicates the interface index.ro Integer32 .dgs6600-system.2.6.1.1.1 |
chassisPortLEDIFNameThis object indicates the interface name.ro DisplayString (SNMPv2-TC) .dgs6600-system.2.6.1.1.2 |
chassisPortLEDStatusThis object indicates the port LED status:
1: The port LED status of the interface index is off.
2: The port LED status of the interface index is steady-amber.
3: The port LED status of the interface index is steady-green.
4: The port LED status of the interface index is blinking-amber.
5: The port LED status of the interface index is blinking-green.ro Enumeration .dgs6600-system.2.6.1.1.3 |
chassisPortLEDModeThis object indicates the port LED mode:
1: The port LED is in Ethernet mode.
2: The poer LED is in PoE mode.ro Enumeration .dgs6600-system.2.6.1.1.4 |
chassisPortLEDMediumTypeThis object indicates the port LED medium type:
1: The medium type of port LED is copper.
2: The medium type of port LED is fiber.ro Enumeration .dgs6600-system.2.6.1.1.5 |