DDM-MGMT-MIB
The structure of DDM for the proprietary enterprise.
Main OID:
swDdmMIB.1.3.6.1.4.1.171.12.72
40
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
40 total| Object Name |
|---|
swDdmMIBThe structure of DDM for the proprietary enterprise. MODULE-IDENTITY .1.3.6.1.4.1.171.12.72 |
swDdmCtrl OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.1 |
swDdmTrapStateThis object indicates the trap action state.rw Enumeration .1.3.6.1.4.1.171.12.72.1.1 |
swDdmLogStateThis object indicates the log action state.rw Enumeration .1.3.6.1.4.1.171.12.72.1.2 |
swDdmInfo OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.2 |
swDdmStatus OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.2.1 |
swDdmStatusTableThis table contains the DDM status information. SEQUENCE OF SwDdmStatusEntry .1.3.6.1.4.1.171.12.72.2.1.1 |
swDdmStatusEntryThis is an entry of the swDdmStatusTable. SwDdmStatusEntry .1.3.6.1.4.1.171.12.72.2.1.1.1 |
swDdmPortThis object indicates the port.ro INTEGER .1.3.6.1.4.1.171.12.72.2.1.1.1.1 |
swDdmTemperatureThis object indicates the real time value of the temperature. As the value is a floating point data type, the DisplayString type is used to define this parameter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.2.1.1.1.2 |
swDdmVoltageThis object indicates the real time value of the supply voltage. As the value value is a floating point data type, the DisplayString type is used to define this parameter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.2.1.1.1.3 |
swDdmBiasCurrentThis object indicates the real time value of the tx bias.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.2.1.1.1.4 |
swDdmTxPowerThis object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.2.1.1.1.5 |
swDdmRxPowerThis object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.2.1.1.1.6 |
swDdmMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.3 |
swDdmThresholdMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.3.1 |
swDdmThresholdMgmtTableThis table contains DDM temperature configuration information. SEQUENCE OF SwDdmThresholdMgmtEntry .1.3.6.1.4.1.171.12.72.3.1.1 |
swDdmThresholdMgmtEntryThis is an entry of the swDdmConfigThresholdTable. SwDdmThresholdMgmtEntry .1.3.6.1.4.1.171.12.72.3.1.1.1 |
swDdmThresholdTypeThis object indicates the threshold type.ro Enumeration .1.3.6.1.4.1.171.12.72.3.1.1.1.1 |
swDdmHighAlarmThis object indicates the high alarm threshold value to be configured. As the value is a floating point data type, the DisplayString type is used to define this parameter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.3.1.1.1.2 |
swDdmLowAlarmThis object indicates the low alarm threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.3.1.1.1.3 |
swDdmHighWarningThis object indicates the high warning threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.3.1.1.1.4 |
swDdmLowWarningThis object indicates the low warning threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.171.12.72.3.1.1.1.5 |
swDdmActionMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.3.2 |
swDdmActionMgmtTableThis table contains the configuration of the action taken when any parameter exceeds its threshold.obsolete SEQUENCE OF SwDdmActionMgmtEntry .1.3.6.1.4.1.171.12.72.3.2.1 |
swDdmActionMgmtEntryThis is an entry of the swDdmConfigActionTable.obsolete SwDdmActionMgmtEntry .1.3.6.1.4.1.171.12.72.3.2.1.1 |
swDdmActionTypeThis object indicates the action type.roobsolete Enumeration .1.3.6.1.4.1.171.12.72.3.2.1.1.1 |
swDdmShutdownThis object indicates the shutdown action. The value 'other' means that the port does not support DDM.rwobsolete Enumeration .1.3.6.1.4.1.171.12.72.3.2.1.1.2 |
swDdmTrapAndLogThis object indicates the trap and log action. The value 'other' means that the port does not support DDM.rwobsolete Enumeration .1.3.6.1.4.1.171.12.72.3.2.1.1.3 |
swDdmPortMgmtTableThis table contains the configuration of the DDM state and shutdown mode when any parameter exceeds its threshold. SEQUENCE OF SwDdmPortMgmtEntry .1.3.6.1.4.1.171.12.72.3.2.2 |
swDdmPortMgmtEntryThis is an entry of the swDdmPortMgmtTable. SwDdmPortMgmtEntry .1.3.6.1.4.1.171.12.72.3.2.2.1 |
swDdmPortStateThis object indicates the DDM state information by port.rw Enumeration .1.3.6.1.4.1.171.12.72.3.2.2.1.1 |
swDdmPortShutdownThis object indicates whether or not to shutdown the port on which the operating parameter exceeds the specified threshold.rw Enumeration .1.3.6.1.4.1.171.12.72.3.2.2.1.2 |
swDdmNotify OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.4 |
swDdmNotifyPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.4.0 |
swDdmAlarmTrapThe trap is sent when any parameter value exceeds the alarm threshold value or recover to normal status depending on the configuration of the trap action. NOTIFICATION-TYPE .1.3.6.1.4.1.171.12.72.4.0.1 |
swDdmWarningTrapThe trap is sent when any parameter value exceeds the warning threshold value or recover to normal status depending on the configuration of the trap action. NOTIFICATION-TYPE .1.3.6.1.4.1.171.12.72.4.0.2 |
swDdmNotificationBinding OBJECT IDENTIFIER .1.3.6.1.4.1.171.12.72.4.1 |
swDdmThresholdExceedTypeThis object is used by swDdmAlarmTrap and swDdmWarningTrap to indicate if the threshold that was exceeded was a high threshold or a low threshold.ro Enumeration .1.3.6.1.4.1.171.12.72.4.1.1 |
swDdmThresholdExceedOrRecoverThis object is used by swDdmAlarmTrap and swDdmWarningTrap,to indicate the GBIC is exceeding its ddm threshold or recover to normal status.ro Enumeration .1.3.6.1.4.1.171.12.72.4.1.2 |