Cisco90Series-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for Cisco90Series-MIB.

168
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

168 total
Object Name
ciscoTelesend
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1570
frMux
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570.1
frxSys
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570.1.1
frxSysDescrDescription of the Cisco 90 Series System.ro
DisplayString
.1.3.6.1.4.1.1570.1.1.1
frxClockHourSynchronized 24 hour clock for the Cisco 90 Series system - Hour. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals.rw
INTEGER
.1.3.6.1.4.1.1570.1.1.2
frxClockMinSynchronized 24 hour clock for the Cisco 90 Series system - Minutes. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals.rw
INTEGER
.1.3.6.1.4.1.1570.1.1.3
frxClockSecSynchronized 24 hour clock for the Cisco 90 Series system - Seconds. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals.rw
INTEGER
.1.3.6.1.4.1.1570.1.1.4
frxUpTimeTime since the agent was last initialized in 0.01 second increments.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.1570.1.1.5
frxAdminContactCisco 90 Series administrative contact name.rw
DisplayString
.1.3.6.1.4.1.1570.1.1.6
frxSysNameAdministratively assigned name for this Cisco 90 Series agent.rw
DisplayString
.1.3.6.1.4.1.1570.1.1.7
frxSysLocPhysical location of the Cisco 90 Series agent.rw
DisplayString
.1.3.6.1.4.1.1570.1.1.8
frxSysVersionCisco 90 Series Agent version number. The version number is an INTEGER representation of the actual version number string. The way to translate to a version number string is 200 = 2.0.0, 201 = 2.0.1, etc.ro
INTEGER
.1.3.6.1.4.1.1570.1.1.9
frxUPerfTrapEnable1=Enable sending the frxUPerfTrap trap to the SNMP manager when a performance monitoring threshold is crossed at an Cisco 90 Series channel unit or a downstream BRITE card. 2=Disable Trap.rw
Enumeration
.1.3.6.1.4.1.1570.1.1.10
frxAgtLinkErrorsNumber of Annex-D signaling link reliability errors between the Cisco 90 Series Agent and the Frame Relay Switch. A signaling reliability error is declared whenever the Cisco 90 Series Agent did not receive a reply from the frame relay switch in response to an Annex-D link integrity poll or full status inquiry pollro
Counter
.1.3.6.1.4.1.1570.1.1.11
frxAgtProtErrorsNumber of Annex-D signaling protocol errors between the Cisco 90 Series Agent and the Frame Relay Switch. A signaling protocol error is declared whenever the Cisco 90 Series Agent receives a reply with incorrect format or sequence numbers from the frame relay switch in response to an Annex-D link integrity poll or full status inquiry pollro
Counter
.1.3.6.1.4.1.1570.1.1.12
frxAgtChInactiveNumber of times the Cisco 90 Series Agent Annex-D signaling channel was declared inactive.ro
Counter
.1.3.6.1.4.1.1570.1.1.13
frxAgtChStatusCurrent status of the Annex-D signaling channel between the Cisco 90 Series Agent and the Frame Relay Switch.ro
Enumeration
.1.3.6.1.4.1.1570.1.1.14
frxDefault
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570.1.2
frxDefaultEnable1=Enable automatic loading of defaults (defined in this group) to the channel unit when the Download Configuration pushbutton on the channel unit faceplate is pushed. 2=Disable loading.rw
Enumeration
.1.3.6.1.4.1.1570.1.2.1
frxDefaultTrap1=Enable sending the frxDownloadTrap trap to the SNMP manager when the Download Configuration pushbutton on the channel unit faceplate is pushed. 2=Disable Traprw
Enumeration
.1.3.6.1.4.1.1570.1.2.2
frxDConfigSrcSystem default for frxConfigSrc - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. 1=Data rate and protocol set by Annex-D assignment rules. 2=Data rate and protocol set by the SNMP variables frxPortSpeed and frxPortProtocolrw
Enumeration
.1.3.6.1.4.1.1570.1.2.3
frxDMgtT391System Default for frxMgtT391 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how often (in seconds) the channel units send an Annex-D poll to the frame relay switch. This is the Annex-D T391 parameter (Typical value 10)rw
INTEGER
.1.3.6.1.4.1.1570.1.2.4
frxDMgtT392System Default for frxMgtT392 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how long (in seconds) the channel unit will wait for a subscriber to send it an Annex-D poll before declaring a link error from the subscriber. This is the Annex-D T392 parameter (Typical value 15)rw
INTEGER
.1.3.6.1.4.1.1570.1.2.5
frxDMgtN391System Default for frxMgtN391 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how often the channel units send a full status inquiry poll to the frame relay switch instead of a link integrity verification poll. This is the Annex-D N391 parameter (Typical value 6)rw
INTEGER
.1.3.6.1.4.1.1570.1.2.6
frxDMgtN392System Default for frxMgtN392 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N392 parameter (Typical value 3)rw
INTEGER
.1.3.6.1.4.1.1570.1.2.7
frxDMgtN393System Default for frxMgtN393 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N393 parameter (Typical value 4)rw
INTEGER
.1.3.6.1.4.1.1570.1.2.8
frxDPortSpeedSystem Default for frxPortSpeed - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the speed that the channel unit port runs at. 1=56kbps 2=64kbps 3=128kbps 4=144kbpsrw
Enumeration
.1.3.6.1.4.1.1570.1.2.9
frxDPortProtocolSystem Default for frxPortProtocol - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. 1=Port uses Frame Relay protocol 2=Port uses PPP protocol - do RFC-1973 encapsulationrw
Enumeration
.1.3.6.1.4.1.1570.1.2.10
frxDCktCIRSystem Default for frxCktCIR - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the committed information rate (CIR) in bits per second. (Typical value 1536000/#ports)rw
INTEGER
.1.3.6.1.4.1.1570.1.2.11
frxDCktBcSystem Default for frxCktBc - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the committed BurstSize (Bc) in bits. The time interval over which the burst is measured is Bc/CIR. (Typically set to same number as frxDCktCIR).rw
INTEGER
.1.3.6.1.4.1.1570.1.2.12
frxDCktBeSystem Default for frxCktBe - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the excess BurstSize (Be) in bits. The time interval over which the excess burst is measured is Be/CIR. (Typical value 1536000).rw
INTEGER
.1.3.6.1.4.1.1570.1.2.13
frxBank
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570.1.3
frxBankTableThis Cisco 90 Series Bank Di-group Table contains channel bank level information for each of the channel bank di-groups in the system. A di-group is a T1 interface to the frame relay network. The table is indexed using the Cisco 90 Series channel bank digroup number
SEQUENCE OF FrxBankEntry
.1.3.6.1.4.1.1570.1.3.1
frxBankEntryA specific entry in the Cisco 90 Series Bank Di-group Table. There is one entry for each channel bank di-group (T1) in the system. There are no entries for unused banks
FrxBankEntry
.1.3.6.1.4.1.1570.1.3.1.1
frxBankIndexChannel Bank Di-group Number. This index is used to address the various channel banks in the system. This number is the same as the DLCI number used to communicate with the bank at the Cisco 90 SNMP Agent. (note that this is NOT the same as the DLCI number at the channel bank. The channel bank always uses DLCI 30 or 31 to communicate with the Agent.)ro
INTEGER
.1.3.6.1.4.1.1570.1.3.1.1.1
frxBankTypeThis is the type of channel bank and is for future use. D4 banks return a value of 1.rw
Enumeration
.1.3.6.1.4.1.1570.1.3.1.1.2
frxChUnit
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570.1.4
frxChUTableThis Cisco 90 Series Channel Unit Table contains channel unit level control and statistics for each of the Cisco 90 Series channel units in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24).
SEQUENCE OF FrxChUEntry
.1.3.6.1.4.1.1570.1.4.1
frxChUEntryA specific entry in the Cisco 90 Series Channel Unit Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots
FrxChUEntry
.1.3.6.1.4.1.1570.1.4.1.1
frxChUIndexChannel Unit Number. This index is used to address a specific channel unit in a bank. For D4 channel banks this number is the same as the physical slot number 1-24ro
INTEGER
.1.3.6.1.4.1.1570.1.4.1.1.1
frxChUTypeType of Cisco 90 Series channel unit installed.ro
Enumeration
.1.3.6.1.4.1.1570.1.4.1.1.2
frxChUVersionCisco 90 Series channel unit version number.ro
INTEGER
.1.3.6.1.4.1.1570.1.4.1.1.3
frxSigProtocolThis is the type of Local In-channel Signaling used when the subscriber is running frame relay protocol. It is provided for future use. Set to 1 for T1.617 Annex-Dro
Enumeration
.1.3.6.1.4.1.1570.1.4.1.1.4
frxConfigSrcSource for configuring speed and protocol for each port. 1=Data rate and protocol set by DLCI assignment rules as reported by Annex-D. This option allows control of these basic parameters from the frame relay switch management station instead of the Cisco 90 Series management station. 2=Data rate and protocol set by SNMP variables frxPortSpeed and frxPortProtocolrw
Enumeration
.1.3.6.1.4.1.1570.1.4.1.1.5
frxDLCIAdLenThe number of bytes used for the DLCI address. For future use. 1=two octets.ro
Enumeration
.1.3.6.1.4.1.1570.1.4.1.1.6
frxNetInOctetsTotal number of octets received by this channel unit from Frame Relay Switch (on the T1 interface) Only frames whose DLCI is addressed to a port on this channel unit are counted. Bad frames, Annex-D and SNMP frames are not counted. CRC bytes are not countedro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.7
frxNetOutOctetsTotal number of octets transmitted to the Frame Relay Switch (on the T1 interface) by this channel unit. Annex-D and SNMP frames are not counted. CRC bytes are not countedro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.8
frxNetBadFramesTotal number of frames received on the network (T1) interface that are discarded by this channel unit. Possible reasons for discard are: Frame contained HDLC abort (7 or more ones in a row) Frame had a CRC error Frame had a non-integral number of bytes Frame was too short (less than 5 bytes) Frame was too long (more than 8192 bytes) Frame had bad RFC-1973 (PPP) header - this error only occurs if destination port is set for PPP protocol. Frame was discarded due to lack of buffer space. Only frames whose DLCI is addressed to a port on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.9
frxNetHDLCEsNetwork Errored Seconds caused by HDLC aborts (7 or more ones in a row). Total number of seconds in which a frame with an HDLC abort is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.10
frxNetCRCEsNetwork Errored Seconds caused by CRC errors. Total number of seconds in which a frame with a CRC error is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.11
frxNetLinkEsNetwork Errored Seconds caused by Non-integral Bytes. Total number of seconds in which a frame with a non-integral number of bytes is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.12
frxNetFrShEsNetwork Errored Seconds caused by Short Frames received. Total number of seconds in which a frame that is too short (less than 5 bytes) is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.13
frxNetFrLgEsNetwork Errored Seconds caused by Long Frames received. Total number of seconds in which a frame that is too long (more than 8192 bytes) is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.14
frxNetPPPEsErrored seconds caused by bad RFC-1973 (PPP) header. Total number of seconds in which a frame with an invalid RFC-1973 (PPP) header is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port that is set to PPP protocol and is on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.15
frxNetBufEsErrored Seconds caused by Buffer Overflow. Total number of seconds in which a frame received by this channel unit on the network (T1) interface was discarded due to insufficient buffer space. Only frames whose DLCI is addressed to a port on this channel unit are counted.ro
Counter
.1.3.6.1.4.1.1570.1.4.1.1.16
frxMgt
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570.1.5
frxMgtTableThis table monitors and controls the T1-617 Annex-D parameters used by the channel units. There is one table row for every channel unit in every bank. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24). For best performance, all of the channel units in a given bank should be set to identical values. These values are typically set using global parameters in the frxDefaultTable instead of directly via this table.
SEQUENCE OF FrxMgtEntry
.1.3.6.1.4.1.1570.1.5.1
frxMgtEntryA specific entry in the Cisco 90 Series Management Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots
FrxMgtEntry
.1.3.6.1.4.1.1570.1.5.1.1
frxPortsInSvcPorts in service. The number of ports on a Cisco 90 Series channel unit that have one or more active PVCs, as determined by Annex-D.ro
INTEGER
.1.3.6.1.4.1.1570.1.5.1.1.1
frxMgtT391This controls how often (in seconds) the channel unit sends an Annex-D poll to the frame relay switch. This is the Annex-D T391 parameter (Typical value 10)rw
INTEGER
.1.3.6.1.4.1.1570.1.5.1.1.2
frxMgtT392This controls how long (in seconds) the channel unit will wait for a subscriber to send it an Annex-D poll before declaring a link error from the subscriber. This is the Annex-D T392 parameter (Typical value 15)rw
INTEGER
.1.3.6.1.4.1.1570.1.5.1.1.3
frxMgtN391This controls how often (in polls) the channel unit sends a full status inquiry poll to the frame relay switch instead of a link integrity verification poll. This is the Annex-D N391 parameter (Typical value 6)rw
INTEGER
.1.3.6.1.4.1.1570.1.5.1.1.4
frxMgtN392When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N392 parameter (Typical value 3)rw
INTEGER
.1.3.6.1.4.1.1570.1.5.1.1.5
frxMgtN393When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N393 parameter (Typical value 4)rw
INTEGER
.1.3.6.1.4.1.1570.1.5.1.1.6
frxNetLinkErrorsNumber of signaling link reliability errors from network. A signaling reliability error is declared whenever the channel units did not receive a reply from the frame relay switch to an Annex-D link integrity poll or full status inquiry pollro
Counter
.1.3.6.1.4.1.1570.1.5.1.1.7
frxNetProtErrorsNumber of signaling protocol errors from network. A signaling protocol error is declared whenever the channel units receive a reply with incorrect format or sequence numbers from the frame relay switch in response to an Annex-D link integrity poll or full status inquiry pollro
Counter
.1.3.6.1.4.1.1570.1.5.1.1.8
frxNetChInactiveNumber of times network Annex-D signaling channel was declared inactive.ro
Counter
.1.3.6.1.4.1.1570.1.5.1.1.9
frxNetChStatusCurrent status of the Annex-D signaling channel on the network side of the channel bank.ro
Enumeration
.1.3.6.1.4.1.1570.1.5.1.1.10
frxMgtPortTableThis table monitors the T1-617 Annex-D link between the channel units and the subscribers. There is one table row for every port on every channel unit in every bank. The table is indexed first using the channel bank digroup number, then the channel unit number (1 to 24), and then the port number (0 to 3).
SEQUENCE OF FrxMgtPortEntry
.1.3.6.1.4.1.1570.1.5.2
frxMgtPortEntryA specific entry in the Cisco 90 Series Management Port Table. There is one entry for each port on each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots.
FrxMgtPortEntry
.1.3.6.1.4.1.1570.1.5.2.1
frxPortIndexWhich subscriber port on the channel unit is addressed. Ports are numbered from 0 to 3. Some channel unit types have less than 4 ports.ro
INTEGER
.1.3.6.1.4.1.1570.1.5.2.1.1
frxPortLinkErrorsNumber of signaling link reliability errors from subscriber port. A signaling reliability error is declared whenever the channel units did not receive an Annex-D link integrity poll or full status inquiry poll from the subscriber port within the required time.ro
Counter
.1.3.6.1.4.1.1570.1.5.2.1.2
frxPortProtErrorsNumber of signaling protocol errors from subscriber port. A signaling protocol error is declared whenever the channel units receive an Annex-D link integrity poll or full status inquiry poll with incorrect format or sequence numbers from the subscriber port.ro
Counter
.1.3.6.1.4.1.1570.1.5.2.1.3
frxPortChInactiveNumber of times the subscriber port Annex-D signaling channel was declared inactivero
Counter
.1.3.6.1.4.1.1570.1.5.2.1.4
frxPort
OBJECT IDENTIFIER
.1.3.6.1.4.1.1570.1.6
frxPortTableThis Cisco 90 Series Port Table contains per-port control and statistics for each of the subscriber ports in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then by the channel unit number (1 to 24), and finally by the port number (0-3).
SEQUENCE OF FrxPortEntry
.1.3.6.1.4.1.1570.1.6.1
frxPortEntryA specific entry in the Cisco 90 Series Port Table. There is one entry for each port on each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots.
FrxPortEntry
.1.3.6.1.4.1.1570.1.6.1.1
frxPortSpeedThis is the speed that the channel unit port runs at. 1=56kbps 2=64kbps 3=128kbps 4=144kbps This parameter can only be changed if frxConfigSrc is set to SNMP.rw
Enumeration
.1.3.6.1.4.1.1570.1.6.1.1.1
frxPortProtocolThis parameter controls what protocol the channel unit should expect the subscriber to send on the port. 1=Port uses Frame Relay protocol - no encapsulation 2=Port uses PPP protocol - do RFC-1973 encapsulation This parameter can only be changed if frxConfigSrc is set to SNMP.rw
Enumeration
.1.3.6.1.4.1.1570.1.6.1.1.2
frxDSLStatusThis is the status of the DSL loop to the subscriber. 1=Loop is down. 2=Frx card has achieved physical layer activation with the first BRITE card or the NT1 if there are no BRITE cards. 3=Link is up but Annex-D is still inactive. The ACT bit has been exchanged with the NT1 indicating a clear channel path to the customer has been established. Ports running protocols (i.e. PPP) that do not support Annex-D will never be in this state. 4=Link is fully up. Annex-D (if appropriate) is active.ro
Enumeration
.1.3.6.1.4.1.1570.1.6.1.1.3
frxPVCAssignedNumber of PVCs assigned to Subscriber Port as determined by Annex-Dro
INTEGER
.1.3.6.1.4.1.1570.1.6.1.1.4
frxLastChangeTime since DSL went in sync or lost sync in 0.01 second increments.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.1570.1.6.1.1.5
frxBriteNumber of BRITE cards downstream. BRITE cards are used to extend the loop over subscriber loop carrier systems and are detected via a background polling operation.ro
INTEGER
.1.3.6.1.4.1.1570.1.6.1.1.6
frxDSLInOctetsNumber of octets received from the subscriber DSL Does not include Annex-D octetsro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.7
frxDSLOutOctetsNumber of octets transmitted to the subscriber DSL. Does not include Annex-D octetsro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.8
frxT1InOctetsNumber of octets received from the network directed at this subscriber portro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.9
frxT1OutOctetsNumber of octets transmitted to the network from this subscriber portro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.10
frxDSLBadFramesTotal number of frames received from this subscriber port that were discarded. Possible reasons for discard are: Frame contained HDLC abort (7 or more ones in a row) Frame had a CRC error Frame had a non-integral number of bytes Frame was too short (less than 5 bytes) Frame was too long (more than 8192 bytes) Frame had illegal DLCI (not 16-23) Frame was discarded due to lack of buffer space or due to congestion controlro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.11
frxDSLHDLCEsSubscriber port Errored Seconds caused by HDLC aborts (7 or more ones in a row). Total number of seconds in which a frame with an HDLC abort is received from this port.ro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.12
frxDSLCRCEsSubscriber port Errored Seconds caused by CRC errors. Total number of seconds in which a frame with a CRC error is received from this port.ro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.13
frxDSLLinkEsSubscriber port Errored Seconds caused by Non-integral Bytes. Total number of seconds in which a frame with a non-integral number of bytes is received from this port.ro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.14
frxDSLFrShEsSubscriber port Errored Seconds caused by Short Frames. received Total number of seconds in which a frame that is too short (less than 5 bytes) is received from this port.ro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.15
frxDSLFrLgEsSubscriber port Errored Seconds caused by Long Frames received. Total number of seconds in which a frame that is too long (more than 8192 bytes) is received from this port.ro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.16
frxDSLDLCIEsSubscriber port Errored Seconds caused by illegal DLCI. Total number of seconds in which a frame that has a DLCI other than 16 to 23 (or 0) is received from this port.ro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.17
frxTxBufNumber of octets in the transmit buffer for this subscriber port. This data is waiting to be sent to the network (T1).ro
INTEGER
.1.3.6.1.4.1.1570.1.6.1.1.18
frxRxBufNumber of octets in the receive buffer for this subscriber port. This data is from the network (T1) and is waiting to be sent to the subscriber port.ro
INTEGER
.1.3.6.1.4.1.1570.1.6.1.1.19
frxPortNetEsTotal number of seconds in which a frame received from the network (T1) and targeted at this subscriber port was discarded.ro
Counter
.1.3.6.1.4.1.1570.1.6.1.1.20
frxCircuitTableThis Cisco 90 Series Circuit Table contains per-virtual-circuit control and statistics for each of the permanent virtual circuits in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then by the channel unit number (1 to 24), then by the port number (0-3) and finally by the circuit DLCI number (16 to 23).
SEQUENCE OF FrxCircuitEntry
.1.3.6.1.4.1.1570.1.6.2
frxCircuitEntryA specific entry in the Cisco 90 Series Circuit Table. There is one entry for each permanent virtual circuit in the system. There are no entries for unused banks or empty channel unit slots.
FrxCircuitEntry
.1.3.6.1.4.1.1570.1.6.2.1
frxPvcIndexThis index is the subscriber loop DLCI number of the permanent virtual circuit. It ranges from 16 to 23. The corresponding network side DLCI must be assigned in the frame relay switch and communicated to the Cisco 90 Series channel units via the Annex-D protocol before this element can be addressed.ro
INTEGER
.1.3.6.1.4.1.1570.1.6.2.1.1
frxCktCIRThis is the committed information rate (CIR) in bits per second for the addressed permanent virtual circuit. (Typical value 1536000/#ports).rw
INTEGER
.1.3.6.1.4.1.1570.1.6.2.1.2
frxCktBcThis is the Committed Burst Size (Bc) in bits for the addressed permanent virtual circuit. The time interval over which the burst is measured is Bc/CIR. (Typically set to same number as frxCktCIR).rw
INTEGER
.1.3.6.1.4.1.1570.1.6.2.1.3
frxCktBeThis is the Excess Burst Size (Be) in bits for the addressed permanent virtual circuit. The time interval over which the excess burst is measured is Be/CIR. (Typical value 1536000).rw
INTEGER
.1.3.6.1.4.1.1570.1.6.2.1.4
frxFarEndOpStatThis is the status of the far end of the frame relay permanent virtual circuit (through the frame relay network) as determined by Annex-D. 1=active 2=inactivero
Enumeration
.1.3.6.1.4.1.1570.1.6.2.1.5
frxCktInOctetsThe number of input octets from the subscriber port on the addressed permanent virtual circuit. These octets are destined for the network (T1).ro
Counter
.1.3.6.1.4.1.1570.1.6.2.1.6
frxCktOutOctetsThe number of output octets to the subscriber port on the addressed permanent virtual circuit. These octets were received from the network (T1).ro
Counter
.1.3.6.1.4.1.1570.1.6.2.1.7
frxCktInFramesThe number of input frames from the subscriber port on the addressed permanent virtual circuit. These frames are destined for the network (T1).ro
Counter
.1.3.6.1.4.1.1570.1.6.2.1.8
frxCktOutFramesThe number of output frames to the subscriber port on the addressed permanent virtual circuit. These frames were received from the network (T1).ro
Counter
.1.3.6.1.4.1.1570.1.6.2.1.9
frxCktDiscardsThe number of input frames from the subscriber port on the addressed permanent virtual circuit that were discarded due to congestion (lack of buffer space or congestion control.ro
Counter
.1.3.6.1.4.1.1570.1.6.2.1.10
frxUEocTableThis Cisco 90 Series Embedded Operations Channel Table is used to diagnose and sectionalize problems with the subscriber loop. It contains one entry for each of the Cisco 90 Series channel units in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24).
SEQUENCE OF FrxUEocEntry
.1.3.6.1.4.1.1570.1.6.3
frxUEocEntryA specific entry in the Cisco 90 Series Embedded Operations Channel Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots
FrxUEocEntry
.1.3.6.1.4.1.1570.1.6.3.1
frxTestPortThis parameter indicates which subscriber port on the channel unit to test. It has no effect until frxStartTest is set to start the test. Only one port on a given channel unit may be tested at a time.rw
INTEGER
.1.3.6.1.4.1.1570.1.6.3.1.1
frxTestTypeThis parameter indicates the type of test to perform. It has no effect until frxStartTest is set to start the test. 1=Set up a loopback and run a PN-2047 Bit Error Rate Test. 2=Run a (straightaway) PN-2047 Bit Error Rate Test. This test assumes a loopback has been manually set up somewhere downstream or another test set running PN-2047 BERT is connected downstream. 3=Send corrupted CRC on the DSL. This has no effect on the frame relay CRC, only the out-of-band DSL CRC (used for performance monitoring) is corrupted. 4=Set up a loopback at the specified location to loop the frame relay or PPP data in both directions. 5=Setup a local loopback on all 4 ports. frxTestPort and frxLoopLoc are ignored for this test.rw
Enumeration
.1.3.6.1.4.1.1570.1.6.3.1.2
frxLoopLocThis parameter indicates the location of the loopback or the card that will send corrupt CRC. It has no effect until frxStartTest is set to start the test. It has no effect for a BertOnly test. 7=Local Cisco 90 Series card 8=NT1 at customer premise 1 to 6 is used to address intervening BRITE cards.rw
Enumeration
.1.3.6.1.4.1.1570.1.6.3.1.3
frxLoopChThis parameter indicates which channels to use for the loopbackOnly and localLoopAllPorts test. It has no effect until frxStartTest is set to start the test. Note that the loopbackAndBert test always loops all channels back. 1=B1 channel 2=B2 channel 3=All channels (includes all B channels plus all D channelsrw
Enumeration
.1.3.6.1.4.1.1570.1.6.3.1.4
frxStartTestThis parameter is used to start and stop the test. frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should be set up prior to starting the test. 1=stop test. 2=start test.rw
Enumeration
.1.3.6.1.4.1.1570.1.6.3.1.5
frxBertRstThis parameter may be used during a LoopbackAndBert test or a BertOnly test to reset the frxBertBE counter. It must be returned to the normal posiion to allow errors to be counted. 1=normal. 2=Reset BERT counter.rw
Enumeration
.1.3.6.1.4.1.1570.1.6.3.1.6
frxBertBEBERT test block errorsro
Counter
.1.3.6.1.4.1.1570.1.6.3.1.7
frxBertTestTimeBERT test time in 0.01 second incrementsro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.1570.1.6.3.1.8
frxTestInProgTest in progress (1); Normal operation (2)ro
Enumeration
.1.3.6.1.4.1.1570.1.6.3.1.9
frxUThrTableThis table contains the U-interface Performance Monitoring Thresholds and Alarms for each of the subscriber loops in the system and for any BRITE cards extending those loops (e.g. using Subscriber Loop Carrier systems) The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24), then the port number (0, 1, etc) and finally the location number (the BRITE card number (1 to 6) or 7 for local parameters in the Cisco 90 Series card). These registers are defined by Bellcore TR-TSY-000829.
SEQUENCE OF FrxUThrEntry
.1.3.6.1.4.1.1570.1.6.4
frxUThrEntryA specific entry in the U-interface Performance Monitoring Threshold table. There is one entry for each port on each Cisco 90 Series channel unit in the system and one entry for each BRITE card extending those ports. There are no entries for unused banks or empty channel unit slots
FrxUThrEntry
.1.3.6.1.4.1.1570.1.6.4.1
frxPAddrIndexThis is the physical location where the performance monitoring takes place. It may be set to localFrx(7) to access and control PM values local to the Cisco 90 Series channel unit. If there are BRITE cards in the subscriber loop between the Cisco 90 Series channel unit and the customer, PM values contained in those cards may be accessed using briteCard1(1) to briteCard6(6) where briteCard1 is the card closest to the Cisco 90 Series channel unit.ro
Enumeration
.1.3.6.1.4.1.1570.1.6.4.1.1
frxChEsThCurrent Hour Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 40. Indexed by Bank.ChannelUnit.Port.Addressrw
INTEGER
.1.3.6.1.4.1.1570.1.6.4.1.2
frxCdEsThCurrent Day Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 100. Indexed by Bank.ChannelUnit.Port.Addressrw
INTEGER
.1.3.6.1.4.1.1570.1.6.4.1.3
frxChSesThCurrent Hour Severely Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 10. Indexed by Bank.ChannelUnit.Port.Addressrw
INTEGER
.1.3.6.1.4.1.1570.1.6.4.1.4
frxCdSesThCurrent Day Severely Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 25. Indexed by Bank.ChannelUnit.Port.Addressrw
INTEGER
.1.3.6.1.4.1.1570.1.6.4.1.5
frxAlertMask8-bit Alert Mask register. One bit for each threshold in both directions. When set to 1, the corresponding threshold crossing is ignored. When set to 0, the corresponding threshold crossing is indicated in frxThCond and may cause a trap to be sent depending on the state of frxUPerfTrapEnable. 1 Current Day Severely Errored Seconds Receive 2 Current Day Severely Errored Seconds Transmit 4 Current Day Errored Seconds Receive 8 Current Day Errored Seconds Receive 16 Current Hour Severely Errored Seconds Receive 32 Current Hour Severely Errored Seconds Transmit 64 Current Hour Errored Seconds Receive 128 Current Hour Errored Seconds Transmit Transmit is data from the customer towards the network. Receive is data from the network towards the Customer. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressrw
INTEGER
.1.3.6.1.4.1.1570.1.6.4.1.6
frxThCond8-bit Threshold Condition register. One bit for each threshold in both directions. Set to 1 if the threshold is exceeded and the corresponding bit in the frxAlertMask register is set to 0. Only set to 0 by the SNMP manager. 1 Current Day Severely Errored Seconds Receive 2 Current Day Severely Errored Seconds Transmit 4 Current Day Errored Seconds Receive 8 Current Day Errored Seconds Receive 16 Current Hour Severely Errored Seconds Receive 32 Current Hour Severely Errored Seconds Transmit 64 Current Hour Errored Seconds Receive 128 Current Hour Errored Seconds Transmit Receive is data from the customer towards the network. Transmit is data from the network towards the Customer. SNMP manager should reset bits to 0 after they it has been read by issuing a set using the inverted byte read. Sets will only reset bits where the set data is a 0. Setting a bit to a 1 has no effect. This register is defined by Bellcore TR-TSY-000829. In the spirit of SNMP, the bits are inverted when read relative to that specification so the sense of the bits is the same for sets and gets. Indexed by Bank.ChannelUnit.Port.Addressrw
INTEGER
.1.3.6.1.4.1.1570.1.6.4.1.7
frxUPerfTableThis table contains the U-interface Performance Monitoring Statistics for each of the subscriber loops in the system and for any BRITE cards extending those loops (e.g. using Subscriber Loop Carrier systems) The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24), then the port number (0, 1, etc) and finally the location number (the BRITE card number (1 to 6) or 7 for local parameters in the Cisco 90 Series card). These registers are defined by Bellcore TR-TSY-000829.
SEQUENCE OF FrxUPerfEntry
.1.3.6.1.4.1.1570.1.6.5
frxUPerfEntryA specific entry in the U-interface Performance Monitoring Statistics table. There is one entry for each port on each Cisco 90 Series channel unit in the system and one entry for each BRITE card extending those ports. There are no entries for unused banks or empty channel unit slots
FrxUPerfEntry
.1.3.6.1.4.1.1570.1.6.5.1
frxResetPMReset all of the performance monitoring statistics on the specified Cisco 90 Series channel unit or BRITE card. 1=Normal. 2=Reset. There is no need to set this register back to Normal after doing a reset.rw
Enumeration
.1.3.6.1.4.1.1570.1.6.5.1.1
frxPMtypeDetermines if the Cisco 90 Series channel unit or the downstream BRITE cards is doing segmented or path performance monitoring as specified in Bellcore document TR-NWT-000397. Only segmented performance monitoring should be used. In segmented PM, CRC errors are counted on each segment of the loop, instead of over the entire path. If no BRITE cards exist in the system, there is no difference between segmented and path PM 1=Segmented. 2=Path.ro
Enumeration
.1.3.6.1.4.1.1570.1.6.5.1.2
frxChEsTxCurrent Hour Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.3
frxChEsRxCurrent Hour Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.4
frxPhEsTxPrevious Hour Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.5
frxPhEsRxPrevious Hour Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.6
frxH2EsTxErrored Seconds 2 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.7
frxH2EsRxErrored Seconds 2 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.8
frxH3EsTxErrored Seconds 3 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.9
frxH3EsRxErrored Seconds 3 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.10
frxH4EsTxErrored Seconds 4 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.11
frxH4EsRxErrored Seconds 4 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.12
frxH5EsTxErrored Seconds 5 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.13
frxH5EsRxErrored Seconds 5 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.14
frxH6EsTxErrored Seconds 6 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.15
frxH6EsRxErrored Seconds 6 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.16
frxH7EsTxErrored Seconds 7 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.17
frxH7EsRxErrored Seconds 7 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.18
frxH8EsTxErrored Seconds 8 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.19
frxH8EsRxErrored Seconds 8 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.20
frxCdEsTxCurrent Day Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.21
frxCdEsRxCurrent Day Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.22
frxPdEsTxPrevious Day Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.23
frxPdEsRxPrevious Day Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.24
frxChSesTxCurrent Hour Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.25
frxChSesRxCurrent Hour Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.26
frxPhSesTxPrevious Hour Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors)ro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.27
frxPhSesRxPrevious Hour Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.28
frxCdSesTxCurrent Day Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.29
frxCdSesRxCurrent Day Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.30
frxPdSesTxPrevious Day Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.31
frxPdSesRxPrevious Day Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.32
frxChBeTxCurrent Hour Block Errors - Transmit direction. Transmit is data from the network towards the customer. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.33
frxChBeRxCurrent Hour Block Errors - Receive direction. Receive is data from the customer towards the network. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.34
frxPhBeTxPrevious Hour Block Errors - Transmit direction. Transmit is data from the network towards the customer. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.35
frxPhBeRxPrevious Hour Block Errors - Receive direction. Receive is data from the customer towards the network. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro
INTEGER
.1.3.6.1.4.1.1570.1.6.5.1.36