Cisco90Series-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for Cisco90Series-MIB.
168
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
168 total| Object Name |
|---|
ciscoTelesend OBJECT IDENTIFIER .1.3.6.1.4.1.1570 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1570 |
frMux OBJECT IDENTIFIER .1.3.6.1.4.1.1570.1 |
frxSys OBJECT IDENTIFIER .1.3.6.1.4.1.1570.1.1 |
frxSysDescrDescription of the Cisco 90 Series System.ro DisplayString .1.3.6.1.4.1.1570.1.1.1 |
frxClockHourSynchronized 24 hour clock for the Cisco 90 Series system -
Hour. This clock is used by the channel units
and BRITE cards to set the performance monitoring
end-of-hour and end-of-day intervals.rw INTEGER .1.3.6.1.4.1.1570.1.1.2 |
frxClockMinSynchronized 24 hour clock for the Cisco 90 Series system -
Minutes. This clock is used by the channel units
and BRITE cards to set the performance monitoring
end-of-hour and end-of-day intervals.rw INTEGER .1.3.6.1.4.1.1570.1.1.3 |
frxClockSecSynchronized 24 hour clock for the Cisco 90 Series system -
Seconds. This clock is used by the channel units
and BRITE cards to set the performance monitoring
end-of-hour and end-of-day intervals.rw INTEGER .1.3.6.1.4.1.1570.1.1.4 |
frxUpTimeTime since the agent was last initialized in
0.01 second increments.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.1570.1.1.5 |
frxAdminContactCisco 90 Series administrative contact name.rw DisplayString .1.3.6.1.4.1.1570.1.1.6 |
frxSysNameAdministratively assigned name for this Cisco 90 Series agent.rw DisplayString .1.3.6.1.4.1.1570.1.1.7 |
frxSysLocPhysical location of the Cisco 90 Series agent.rw DisplayString .1.3.6.1.4.1.1570.1.1.8 |
frxSysVersionCisco 90 Series Agent version number. The version number is
an INTEGER representation of the actual version number string.
The way to translate to a version number string is 200 = 2.0.0,
201 = 2.0.1, etc.ro INTEGER .1.3.6.1.4.1.1570.1.1.9 |
frxUPerfTrapEnable1=Enable sending the frxUPerfTrap trap to the
SNMP manager when a performance monitoring
threshold is crossed at an Cisco 90 Series channel unit or
a downstream BRITE card.
2=Disable Trap.rw Enumeration .1.3.6.1.4.1.1570.1.1.10 |
frxAgtLinkErrorsNumber of Annex-D signaling link reliability errors
between the Cisco 90 Series Agent and the Frame Relay Switch.
A signaling reliability error is declared whenever
the Cisco 90 Series Agent did not receive a reply from the
frame relay switch in response to an Annex-D link
integrity poll or full status inquiry pollro Counter .1.3.6.1.4.1.1570.1.1.11 |
frxAgtProtErrorsNumber of Annex-D signaling protocol errors
between the Cisco 90 Series Agent and the Frame
Relay Switch. A signaling protocol error is
declared whenever the Cisco 90 Series Agent
receives a reply with incorrect format or
sequence numbers from the frame relay switch in
response to an Annex-D link integrity poll or
full status inquiry pollro Counter .1.3.6.1.4.1.1570.1.1.12 |
frxAgtChInactiveNumber of times the Cisco 90 Series Agent Annex-D signaling
channel was declared inactive.ro Counter .1.3.6.1.4.1.1570.1.1.13 |
frxAgtChStatusCurrent status of the Annex-D signaling channel
between the Cisco 90 Series Agent and the Frame Relay Switch.ro Enumeration .1.3.6.1.4.1.1570.1.1.14 |
frxDefault OBJECT IDENTIFIER .1.3.6.1.4.1.1570.1.2 |
frxDefaultEnable1=Enable automatic loading of defaults (defined
in this group) to the channel unit when the
Download Configuration pushbutton on the channel
unit faceplate is pushed. 2=Disable loading.rw Enumeration .1.3.6.1.4.1.1570.1.2.1 |
frxDefaultTrap1=Enable sending the frxDownloadTrap trap to
the SNMP manager when the Download Configuration
pushbutton on the channel unit faceplate is pushed.
2=Disable Traprw Enumeration .1.3.6.1.4.1.1570.1.2.2 |
frxDConfigSrcSystem default for frxConfigSrc - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
1=Data rate and protocol set by Annex-D assignment rules.
2=Data rate and protocol set by the SNMP variables
frxPortSpeed and frxPortProtocolrw Enumeration .1.3.6.1.4.1.1570.1.2.3 |
frxDMgtT391System Default for frxMgtT391 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This controls how often (in seconds) the channel units
send an Annex-D poll to the frame relay switch.
This is the Annex-D T391 parameter (Typical value 10)rw INTEGER .1.3.6.1.4.1.1570.1.2.4 |
frxDMgtT392System Default for frxMgtT392 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This controls how long (in seconds) the channel unit
will wait for a subscriber to send it an Annex-D poll
before declaring a link error from the subscriber.
This is the Annex-D T392 parameter (Typical value 15)rw INTEGER .1.3.6.1.4.1.1570.1.2.5 |
frxDMgtN391System Default for frxMgtN391 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This controls how often the channel units send a full
status inquiry poll to the frame relay switch instead of
a link integrity verification poll.
This is the Annex-D N391 parameter (Typical value 6)rw INTEGER .1.3.6.1.4.1.1570.1.2.6 |
frxDMgtN392System Default for frxMgtN392 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive.
This is the Annex-D N392 parameter (Typical value 3)rw INTEGER .1.3.6.1.4.1.1570.1.2.7 |
frxDMgtN393System Default for frxMgtN393 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive.
This is the Annex-D N393 parameter (Typical value 4)rw INTEGER .1.3.6.1.4.1.1570.1.2.8 |
frxDPortSpeedSystem Default for frxPortSpeed - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the speed that the channel unit port runs at.
1=56kbps 2=64kbps 3=128kbps 4=144kbpsrw Enumeration .1.3.6.1.4.1.1570.1.2.9 |
frxDPortProtocolSystem Default for frxPortProtocol - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
1=Port uses Frame Relay protocol
2=Port uses PPP protocol - do RFC-1973 encapsulationrw Enumeration .1.3.6.1.4.1.1570.1.2.10 |
frxDCktCIRSystem Default for frxCktCIR - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the committed information rate (CIR) in bits per
second. (Typical value 1536000/#ports)rw INTEGER .1.3.6.1.4.1.1570.1.2.11 |
frxDCktBcSystem Default for frxCktBc - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the committed BurstSize (Bc) in bits. The time
interval over which the burst is measured is Bc/CIR.
(Typically set to same number as frxDCktCIR).rw INTEGER .1.3.6.1.4.1.1570.1.2.12 |
frxDCktBeSystem Default for frxCktBe - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the excess BurstSize (Be) in bits. The time
interval over which the excess burst is measured is Be/CIR.
(Typical value 1536000).rw INTEGER .1.3.6.1.4.1.1570.1.2.13 |
frxBank OBJECT IDENTIFIER .1.3.6.1.4.1.1570.1.3 |
frxBankTableThis Cisco 90 Series Bank Di-group Table contains channel
bank level information for each of the channel bank di-groups
in the system. A di-group is a T1 interface to the frame
relay network. The table is indexed using the Cisco 90 Series
channel bank digroup number SEQUENCE OF FrxBankEntry .1.3.6.1.4.1.1570.1.3.1 |
frxBankEntryA specific entry in the Cisco 90 Series Bank Di-group
Table. There is one entry for each channel bank di-group
(T1) in the system. There are no entries for unused banks FrxBankEntry .1.3.6.1.4.1.1570.1.3.1.1 |
frxBankIndexChannel Bank Di-group Number. This index is used to address
the various channel banks in the system. This number is the
same as the DLCI number used to communicate with the bank at
the Cisco 90 SNMP Agent. (note that this is NOT the same
as the DLCI number at the channel bank. The channel bank
always uses DLCI 30 or 31 to communicate with the Agent.)ro INTEGER .1.3.6.1.4.1.1570.1.3.1.1.1 |
frxBankTypeThis is the type of channel bank and is for future use.
D4 banks return a value of 1.rw Enumeration .1.3.6.1.4.1.1570.1.3.1.1.2 |
frxChUnit OBJECT IDENTIFIER .1.3.6.1.4.1.1570.1.4 |
frxChUTableThis Cisco 90 Series Channel Unit Table contains channel unit
level control and statistics for each of the Cisco 90 Series
channel units in the system. The table is indexed
first using the Cisco 90 Series channel bank digroup number,
then the channel unit number (1 to 24). SEQUENCE OF FrxChUEntry .1.3.6.1.4.1.1570.1.4.1 |
frxChUEntryA specific entry in the Cisco 90 Series Channel Unit Table.
There is one entry for each Cisco 90 Series channel unit in
the system. There are no entries for unused banks or empty
channel unit slots FrxChUEntry .1.3.6.1.4.1.1570.1.4.1.1 |
frxChUIndexChannel Unit Number. This index is used to address a
specific channel unit in a bank. For D4 channel banks
this number is the same as the physical slot number 1-24ro INTEGER .1.3.6.1.4.1.1570.1.4.1.1.1 |
frxChUTypeType of Cisco 90 Series channel unit installed.ro Enumeration .1.3.6.1.4.1.1570.1.4.1.1.2 |
frxChUVersionCisco 90 Series channel unit version number.ro INTEGER .1.3.6.1.4.1.1570.1.4.1.1.3 |
frxSigProtocolThis is the type of Local In-channel Signaling used
when the subscriber is running frame relay protocol.
It is provided for future use. Set to 1 for T1.617
Annex-Dro Enumeration .1.3.6.1.4.1.1570.1.4.1.1.4 |
frxConfigSrcSource for configuring speed and protocol for each port.
1=Data rate and protocol set by DLCI assignment rules
as reported by Annex-D. This option allows control
of these basic parameters from the frame relay switch
management station instead of the Cisco 90 Series
management station.
2=Data rate and protocol set by SNMP variables
frxPortSpeed and frxPortProtocolrw Enumeration .1.3.6.1.4.1.1570.1.4.1.1.5 |
frxDLCIAdLenThe number of bytes used for the DLCI address.
For future use. 1=two octets.ro Enumeration .1.3.6.1.4.1.1570.1.4.1.1.6 |
frxNetInOctetsTotal number of octets received by this channel
unit from Frame Relay Switch (on the T1 interface)
Only frames whose DLCI is addressed to a port on
this channel unit are counted. Bad frames, Annex-D
and SNMP frames are not counted. CRC bytes are not
countedro Counter .1.3.6.1.4.1.1570.1.4.1.1.7 |
frxNetOutOctetsTotal number of octets transmitted to the Frame
Relay Switch (on the T1 interface) by this channel
unit. Annex-D and SNMP frames are not counted. CRC
bytes are not countedro Counter .1.3.6.1.4.1.1570.1.4.1.1.8 |
frxNetBadFramesTotal number of frames received on the network (T1)
interface that are discarded by this channel unit.
Possible reasons for discard are:
Frame contained HDLC abort (7 or more ones in a row)
Frame had a CRC error
Frame had a non-integral number of bytes
Frame was too short (less than 5 bytes)
Frame was too long (more than 8192 bytes)
Frame had bad RFC-1973 (PPP) header - this error only
occurs if destination port is set for PPP protocol.
Frame was discarded due to lack of buffer space.
Only frames whose DLCI is addressed to a port on
this channel unit are counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.9 |
frxNetHDLCEsNetwork Errored Seconds caused by HDLC aborts (7 or more
ones in a row). Total number of seconds in which a frame
with an HDLC abort is received by this channel unit on
the network (T1) interface. Only frames whose DLCI is
addressed to a port on this channel unit are counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.10 |
frxNetCRCEsNetwork Errored Seconds caused by CRC errors.
Total number of seconds in which a frame with a CRC
error is received by this channel unit on the network
(T1) interface. Only frames whose DLCI is addressed
to a port on this channel unit are counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.11 |
frxNetLinkEsNetwork Errored Seconds caused by Non-integral Bytes.
Total number of seconds in which a frame with a non-integral
number of bytes is received by this channel unit on the
network (T1) interface. Only frames whose DLCI is addressed
to a port on this channel unit are counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.12 |
frxNetFrShEsNetwork Errored Seconds caused by Short Frames received.
Total number of seconds in which a frame that is too
short (less than 5 bytes) is received by this channel
unit on the network (T1) interface. Only frames whose
DLCI is addressed to a port on this channel unit are
counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.13 |
frxNetFrLgEsNetwork Errored Seconds caused by Long Frames received.
Total number of seconds in which a frame that is too
long (more than 8192 bytes) is received by this channel
unit on the network (T1) interface. Only frames whose
DLCI is addressed to a port on this channel unit are
counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.14 |
frxNetPPPEsErrored seconds caused by bad RFC-1973 (PPP) header.
Total number of seconds in which a frame with an
invalid RFC-1973 (PPP) header is received by this
channel unit on the network (T1) interface. Only frames
whose DLCI is addressed to a port that is set to PPP
protocol and is on this channel unit are counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.15 |
frxNetBufEsErrored Seconds caused by Buffer Overflow.
Total number of seconds in which a frame received
by this channel unit on the network (T1) interface
was discarded due to insufficient buffer space. Only
frames whose DLCI is addressed to a port on this
channel unit are counted.ro Counter .1.3.6.1.4.1.1570.1.4.1.1.16 |
frxMgt OBJECT IDENTIFIER .1.3.6.1.4.1.1570.1.5 |
frxMgtTableThis table monitors and controls the T1-617 Annex-D
parameters used by the channel units. There is one
table row for every channel unit in every bank. The
table is indexed first using the Cisco 90 Series channel
bank digroup number, then the channel unit number (1 to 24).
For best performance, all of the channel units in a
given bank should be set to identical values. These
values are typically set using global parameters in the
frxDefaultTable instead of directly via this table. SEQUENCE OF FrxMgtEntry .1.3.6.1.4.1.1570.1.5.1 |
frxMgtEntryA specific entry in the Cisco 90 Series Management Table.
There is one entry for each Cisco 90 Series channel unit
in the system. There are no entries for unused banks or
empty channel unit slots FrxMgtEntry .1.3.6.1.4.1.1570.1.5.1.1 |
frxPortsInSvcPorts in service. The number of ports on a Cisco 90 Series
channel unit that have one or more active PVCs, as determined
by Annex-D.ro INTEGER .1.3.6.1.4.1.1570.1.5.1.1.1 |
frxMgtT391This controls how often (in seconds) the channel unit
sends an Annex-D poll to the frame relay switch.
This is the Annex-D T391 parameter (Typical value 10)rw INTEGER .1.3.6.1.4.1.1570.1.5.1.1.2 |
frxMgtT392This controls how long (in seconds) the channel unit
will wait for a subscriber to send it an Annex-D poll
before declaring a link error from the subscriber.
This is the Annex-D T392 parameter (Typical value 15)rw INTEGER .1.3.6.1.4.1.1570.1.5.1.1.3 |
frxMgtN391This controls how often (in polls) the channel unit
sends a full status inquiry poll to the frame relay
switch instead of a link integrity verification poll.
This is the Annex-D N391 parameter (Typical value 6)rw INTEGER .1.3.6.1.4.1.1570.1.5.1.1.4 |
frxMgtN392When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive. This is the Annex-D N392 parameter
(Typical value 3)rw INTEGER .1.3.6.1.4.1.1570.1.5.1.1.5 |
frxMgtN393When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive. This is the Annex-D N393 parameter
(Typical value 4)rw INTEGER .1.3.6.1.4.1.1570.1.5.1.1.6 |
frxNetLinkErrorsNumber of signaling link reliability errors from
network. A signaling reliability error is declared
whenever the channel units did not receive a reply
from the frame relay switch to an Annex-D link
integrity poll or full status inquiry pollro Counter .1.3.6.1.4.1.1570.1.5.1.1.7 |
frxNetProtErrorsNumber of signaling protocol errors from network.
A signaling protocol error is declared whenever
the channel units receive a reply with incorrect
format or sequence numbers from the frame relay
switch in response to an Annex-D link integrity
poll or full status inquiry pollro Counter .1.3.6.1.4.1.1570.1.5.1.1.8 |
frxNetChInactiveNumber of times network Annex-D signaling channel
was declared inactive.ro Counter .1.3.6.1.4.1.1570.1.5.1.1.9 |
frxNetChStatusCurrent status of the Annex-D signaling channel on
the network side of the channel bank.ro Enumeration .1.3.6.1.4.1.1570.1.5.1.1.10 |
frxMgtPortTableThis table monitors the T1-617 Annex-D link
between the channel units and the subscribers.
There is one table row for every port on every
channel unit in every bank. The table is indexed
first using the channel bank digroup number, then
the channel unit number (1 to 24), and then the
port number (0 to 3). SEQUENCE OF FrxMgtPortEntry .1.3.6.1.4.1.1570.1.5.2 |
frxMgtPortEntryA specific entry in the Cisco 90 Series Management Port
Table. There is one entry for each port on each
Cisco 90 Series channel unit in the system. There are no
entries for unused banks or empty channel unit
slots. FrxMgtPortEntry .1.3.6.1.4.1.1570.1.5.2.1 |
frxPortIndexWhich subscriber port on the channel unit is
addressed. Ports are numbered from 0 to 3.
Some channel unit types have less than 4 ports.ro INTEGER .1.3.6.1.4.1.1570.1.5.2.1.1 |
frxPortLinkErrorsNumber of signaling link reliability errors from
subscriber port. A signaling reliability error is
declared whenever the channel units did not receive
an Annex-D link integrity poll or full status inquiry
poll from the subscriber port within the required time.ro Counter .1.3.6.1.4.1.1570.1.5.2.1.2 |
frxPortProtErrorsNumber of signaling protocol errors from subscriber
port. A signaling protocol error is declared whenever
the channel units receive an Annex-D link integrity
poll or full status inquiry poll with incorrect
format or sequence numbers from the subscriber port.ro Counter .1.3.6.1.4.1.1570.1.5.2.1.3 |
frxPortChInactiveNumber of times the subscriber port Annex-D signaling
channel was declared inactivero Counter .1.3.6.1.4.1.1570.1.5.2.1.4 |
frxPort OBJECT IDENTIFIER .1.3.6.1.4.1.1570.1.6 |
frxPortTableThis Cisco 90 Series Port Table contains per-port control and
statistics for each of the subscriber ports in the
system. The table is indexed first using the Cisco 90 Series
channel bank digroup number, then by the channel
unit number (1 to 24), and finally by the port
number (0-3). SEQUENCE OF FrxPortEntry .1.3.6.1.4.1.1570.1.6.1 |
frxPortEntryA specific entry in the Cisco 90 Series Port Table. There is
one entry for each port on each Cisco 90 Series channel unit
in the system. There are no entries for unused banks or
empty channel unit slots. FrxPortEntry .1.3.6.1.4.1.1570.1.6.1.1 |
frxPortSpeedThis is the speed that the channel unit port runs at.
1=56kbps 2=64kbps 3=128kbps 4=144kbps
This parameter can only be changed if frxConfigSrc is
set to SNMP.rw Enumeration .1.3.6.1.4.1.1570.1.6.1.1.1 |
frxPortProtocolThis parameter controls what protocol the channel
unit should expect the subscriber to send on the port.
1=Port uses Frame Relay protocol - no encapsulation
2=Port uses PPP protocol - do RFC-1973 encapsulation
This parameter can only be changed if frxConfigSrc is
set to SNMP.rw Enumeration .1.3.6.1.4.1.1570.1.6.1.1.2 |
frxDSLStatusThis is the status of the DSL loop to the subscriber.
1=Loop is down.
2=Frx card has achieved physical layer activation with
the first BRITE card or the NT1 if there are no BRITE cards.
3=Link is up but Annex-D is still inactive. The ACT bit has
been exchanged with the NT1 indicating a clear channel path
to the customer has been established. Ports running protocols
(i.e. PPP) that do not support Annex-D will never be in this
state.
4=Link is fully up. Annex-D (if appropriate) is active.ro Enumeration .1.3.6.1.4.1.1570.1.6.1.1.3 |
frxPVCAssignedNumber of PVCs assigned to Subscriber Port as determined
by Annex-Dro INTEGER .1.3.6.1.4.1.1570.1.6.1.1.4 |
frxLastChangeTime since DSL went in sync or lost sync in 0.01
second increments.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.1570.1.6.1.1.5 |
frxBriteNumber of BRITE cards downstream. BRITE cards are used
to extend the loop over subscriber loop carrier systems
and are detected via a background polling operation.ro INTEGER .1.3.6.1.4.1.1570.1.6.1.1.6 |
frxDSLInOctetsNumber of octets received from the subscriber DSL
Does not include Annex-D octetsro Counter .1.3.6.1.4.1.1570.1.6.1.1.7 |
frxDSLOutOctetsNumber of octets transmitted to the subscriber DSL.
Does not include Annex-D octetsro Counter .1.3.6.1.4.1.1570.1.6.1.1.8 |
frxT1InOctetsNumber of octets received from the network
directed at this subscriber portro Counter .1.3.6.1.4.1.1570.1.6.1.1.9 |
frxT1OutOctetsNumber of octets transmitted to the network
from this subscriber portro Counter .1.3.6.1.4.1.1570.1.6.1.1.10 |
frxDSLBadFramesTotal number of frames received from this subscriber port
that were discarded. Possible reasons for discard are:
Frame contained HDLC abort (7 or more ones in a row)
Frame had a CRC error
Frame had a non-integral number of bytes
Frame was too short (less than 5 bytes)
Frame was too long (more than 8192 bytes)
Frame had illegal DLCI (not 16-23)
Frame was discarded due to lack of buffer space or
due to congestion controlro Counter .1.3.6.1.4.1.1570.1.6.1.1.11 |
frxDSLHDLCEsSubscriber port Errored Seconds caused by HDLC aborts
(7 or more ones in a row). Total number of seconds in
which a frame with an HDLC abort is received from this
port.ro Counter .1.3.6.1.4.1.1570.1.6.1.1.12 |
frxDSLCRCEsSubscriber port Errored Seconds caused by CRC errors.
Total number of seconds in which a frame with a CRC
error is received from this port.ro Counter .1.3.6.1.4.1.1570.1.6.1.1.13 |
frxDSLLinkEsSubscriber port Errored Seconds caused by Non-integral
Bytes. Total number of seconds in which a frame with a
non-integral number of bytes is received from this
port.ro Counter .1.3.6.1.4.1.1570.1.6.1.1.14 |
frxDSLFrShEsSubscriber port Errored Seconds caused by Short Frames.
received Total number of seconds in which a frame that
is too short (less than 5 bytes) is received from this
port.ro Counter .1.3.6.1.4.1.1570.1.6.1.1.15 |
frxDSLFrLgEsSubscriber port Errored Seconds caused by Long Frames
received. Total number of seconds in which a frame that
is too long (more than 8192 bytes) is received from this
port.ro Counter .1.3.6.1.4.1.1570.1.6.1.1.16 |
frxDSLDLCIEsSubscriber port Errored Seconds caused by illegal DLCI.
Total number of seconds in which a frame that has a DLCI
other than 16 to 23 (or 0) is received from this port.ro Counter .1.3.6.1.4.1.1570.1.6.1.1.17 |
frxTxBufNumber of octets in the transmit buffer for this
subscriber port. This data is waiting to be sent
to the network (T1).ro INTEGER .1.3.6.1.4.1.1570.1.6.1.1.18 |
frxRxBufNumber of octets in the receive buffer for this
subscriber port. This data is from the network (T1)
and is waiting to be sent to the subscriber port.ro INTEGER .1.3.6.1.4.1.1570.1.6.1.1.19 |
frxPortNetEsTotal number of seconds in which a frame received
from the network (T1) and targeted at this subscriber
port was discarded.ro Counter .1.3.6.1.4.1.1570.1.6.1.1.20 |
frxCircuitTableThis Cisco 90 Series Circuit Table contains
per-virtual-circuit control and statistics for each of the
permanent virtual circuits in the system. The table is
indexed first using the Cisco 90 Series channel bank
digroup number, then by the channel unit number (1 to 24),
then by the port number (0-3) and finally by the circuit
DLCI number (16 to 23). SEQUENCE OF FrxCircuitEntry .1.3.6.1.4.1.1570.1.6.2 |
frxCircuitEntryA specific entry in the Cisco 90 Series Circuit Table.
There is one entry for each permanent virtual circuit
in the system. There are no entries for unused
banks or empty channel unit slots. FrxCircuitEntry .1.3.6.1.4.1.1570.1.6.2.1 |
frxPvcIndexThis index is the subscriber loop DLCI number of the
permanent virtual circuit. It ranges from 16 to 23.
The corresponding network side DLCI must be assigned
in the frame relay switch and communicated to the Cisco 90
Series channel units via the Annex-D protocol before this
element can be addressed.ro INTEGER .1.3.6.1.4.1.1570.1.6.2.1.1 |
frxCktCIRThis is the committed information rate (CIR) in bits
per second for the addressed permanent virtual circuit.
(Typical value 1536000/#ports).rw INTEGER .1.3.6.1.4.1.1570.1.6.2.1.2 |
frxCktBcThis is the Committed Burst Size (Bc) in bits for the
addressed permanent virtual circuit. The time interval
over which the burst is measured is Bc/CIR. (Typically
set to same number as frxCktCIR).rw INTEGER .1.3.6.1.4.1.1570.1.6.2.1.3 |
frxCktBeThis is the Excess Burst Size (Be) in bits for the
addressed permanent virtual circuit. The time interval
over which the excess burst is measured is Be/CIR.
(Typical value 1536000).rw INTEGER .1.3.6.1.4.1.1570.1.6.2.1.4 |
frxFarEndOpStatThis is the status of the far end of the frame relay
permanent virtual circuit (through the frame relay
network) as determined by Annex-D.
1=active
2=inactivero Enumeration .1.3.6.1.4.1.1570.1.6.2.1.5 |
frxCktInOctetsThe number of input octets from the subscriber port
on the addressed permanent virtual circuit. These
octets are destined for the network (T1).ro Counter .1.3.6.1.4.1.1570.1.6.2.1.6 |
frxCktOutOctetsThe number of output octets to the subscriber port
on the addressed permanent virtual circuit. These
octets were received from the network (T1).ro Counter .1.3.6.1.4.1.1570.1.6.2.1.7 |
frxCktInFramesThe number of input frames from the subscriber port
on the addressed permanent virtual circuit. These
frames are destined for the network (T1).ro Counter .1.3.6.1.4.1.1570.1.6.2.1.8 |
frxCktOutFramesThe number of output frames to the subscriber port
on the addressed permanent virtual circuit. These
frames were received from the network (T1).ro Counter .1.3.6.1.4.1.1570.1.6.2.1.9 |
frxCktDiscardsThe number of input frames from the subscriber port
on the addressed permanent virtual circuit that were
discarded due to congestion (lack of buffer space or
congestion control.ro Counter .1.3.6.1.4.1.1570.1.6.2.1.10 |
frxUEocTableThis Cisco 90 Series Embedded Operations Channel Table
is used to diagnose and sectionalize problems with the
subscriber loop. It contains one entry for each of the
Cisco 90 Series channel units in the system. The table
is indexed first using the Cisco 90 Series channel bank
digroup number, then the channel unit number (1 to 24). SEQUENCE OF FrxUEocEntry .1.3.6.1.4.1.1570.1.6.3 |
frxUEocEntryA specific entry in the Cisco 90 Series Embedded Operations
Channel Table. There is one entry for each Cisco 90 Series
channel unit in the system. There are no entries for unused
banks or empty channel unit slots FrxUEocEntry .1.3.6.1.4.1.1570.1.6.3.1 |
frxTestPortThis parameter indicates which subscriber port on the
channel unit to test. It has no effect until frxStartTest
is set to start the test. Only one port on a given channel
unit may be tested at a time.rw INTEGER .1.3.6.1.4.1.1570.1.6.3.1.1 |
frxTestTypeThis parameter indicates the type of test to perform. It
has no effect until frxStartTest is set to start the test.
1=Set up a loopback and run a PN-2047 Bit Error Rate Test.
2=Run a (straightaway) PN-2047 Bit Error Rate Test. This
test assumes a loopback has been manually set up somewhere
downstream or another test set running PN-2047 BERT is
connected downstream.
3=Send corrupted CRC on the DSL. This has no effect on the
frame relay CRC, only the out-of-band DSL CRC (used for
performance monitoring) is corrupted.
4=Set up a loopback at the specified location to loop the
frame relay or PPP data in both directions.
5=Setup a local loopback on all 4 ports. frxTestPort and
frxLoopLoc are ignored for this test.rw Enumeration .1.3.6.1.4.1.1570.1.6.3.1.2 |
frxLoopLocThis parameter indicates the location of the loopback or
the card that will send corrupt CRC. It has no effect
until frxStartTest is set to start the test. It has no
effect for a BertOnly test.
7=Local Cisco 90 Series card 8=NT1 at customer premise
1 to 6 is used to address intervening BRITE cards.rw Enumeration .1.3.6.1.4.1.1570.1.6.3.1.3 |
frxLoopChThis parameter indicates which channels to use for the
loopbackOnly and localLoopAllPorts test. It has no effect
until frxStartTest is set to start the test. Note that the
loopbackAndBert test always loops all channels back.
1=B1 channel 2=B2 channel 3=All channels (includes all
B channels plus all D channelsrw Enumeration .1.3.6.1.4.1.1570.1.6.3.1.4 |
frxStartTestThis parameter is used to start and stop the test.
frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should
be set up prior to starting the test.
1=stop test. 2=start test.rw Enumeration .1.3.6.1.4.1.1570.1.6.3.1.5 |
frxBertRstThis parameter may be used during a LoopbackAndBert test
or a BertOnly test to reset the frxBertBE counter. It
must be returned to the normal posiion to allow errors to
be counted.
1=normal. 2=Reset BERT counter.rw Enumeration .1.3.6.1.4.1.1570.1.6.3.1.6 |
frxBertBEBERT test block errorsro Counter .1.3.6.1.4.1.1570.1.6.3.1.7 |
frxBertTestTimeBERT test time in 0.01 second incrementsro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.1570.1.6.3.1.8 |
frxTestInProgTest in progress (1); Normal operation (2)ro Enumeration .1.3.6.1.4.1.1570.1.6.3.1.9 |
frxUThrTableThis table contains the U-interface Performance Monitoring
Thresholds and Alarms for each of the subscriber loops in
the system and for any BRITE cards extending those loops
(e.g. using Subscriber Loop Carrier systems) The table is
indexed first using the Cisco 90 Series channel bank digroup
number, then the channel unit number (1 to 24), then the port
number (0, 1, etc) and finally the location number (the BRITE
card number (1 to 6) or 7 for local parameters in the Cisco
90 Series card). These registers are defined by Bellcore
TR-TSY-000829. SEQUENCE OF FrxUThrEntry .1.3.6.1.4.1.1570.1.6.4 |
frxUThrEntryA specific entry in the U-interface Performance Monitoring
Threshold table. There is one entry for each port on each
Cisco 90 Series channel unit in the system and one entry for
each BRITE card extending those ports. There are no entries
for unused banks or empty channel unit slots FrxUThrEntry .1.3.6.1.4.1.1570.1.6.4.1 |
frxPAddrIndexThis is the physical location where the performance
monitoring takes place. It may be set to localFrx(7)
to access and control PM values local to the Cisco 90
Series channel unit. If there are BRITE cards in the
subscriber loop between the Cisco 90 Series channel
unit and the customer, PM values contained in those
cards may be accessed using briteCard1(1) to
briteCard6(6) where briteCard1 is the card closest
to the Cisco 90 Series channel unit.ro Enumeration .1.3.6.1.4.1.1570.1.6.4.1.1 |
frxChEsThCurrent Hour Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 40.
Indexed by Bank.ChannelUnit.Port.Addressrw INTEGER .1.3.6.1.4.1.1570.1.6.4.1.2 |
frxCdEsThCurrent Day Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 100.
Indexed by Bank.ChannelUnit.Port.Addressrw INTEGER .1.3.6.1.4.1.1570.1.6.4.1.3 |
frxChSesThCurrent Hour Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 10.
Indexed by Bank.ChannelUnit.Port.Addressrw INTEGER .1.3.6.1.4.1.1570.1.6.4.1.4 |
frxCdSesThCurrent Day Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 25.
Indexed by Bank.ChannelUnit.Port.Addressrw INTEGER .1.3.6.1.4.1.1570.1.6.4.1.5 |
frxAlertMask8-bit Alert Mask register. One bit for each threshold in
both directions. When set to 1, the corresponding threshold
crossing is ignored. When set to 0, the corresponding threshold
crossing is indicated in frxThCond and may cause a trap to be
sent depending on the state of frxUPerfTrapEnable.
1 Current Day Severely Errored Seconds Receive
2 Current Day Severely Errored Seconds Transmit
4 Current Day Errored Seconds Receive
8 Current Day Errored Seconds Receive
16 Current Hour Severely Errored Seconds Receive
32 Current Hour Severely Errored Seconds Transmit
64 Current Hour Errored Seconds Receive
128 Current Hour Errored Seconds Transmit
Transmit is data from the customer towards the network.
Receive is data from the network towards the Customer.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Addressrw INTEGER .1.3.6.1.4.1.1570.1.6.4.1.6 |
frxThCond8-bit Threshold Condition register. One bit for each
threshold in both directions. Set to 1 if the threshold
is exceeded and the corresponding bit in the frxAlertMask
register is set to 0. Only set to 0 by the SNMP manager.
1 Current Day Severely Errored Seconds Receive
2 Current Day Severely Errored Seconds Transmit
4 Current Day Errored Seconds Receive
8 Current Day Errored Seconds Receive
16 Current Hour Severely Errored Seconds Receive
32 Current Hour Severely Errored Seconds Transmit
64 Current Hour Errored Seconds Receive
128 Current Hour Errored Seconds Transmit
Receive is data from the customer towards the network.
Transmit is data from the network towards the Customer.
SNMP manager should reset bits to 0 after they it has been
read by issuing a set using the inverted byte read. Sets
will only reset bits where the set data is a 0. Setting
a bit to a 1 has no effect. This register is defined
by Bellcore TR-TSY-000829. In the spirit of SNMP, the bits
are inverted when read relative to that specification so
the sense of the bits is the same for sets and gets.
Indexed by Bank.ChannelUnit.Port.Addressrw INTEGER .1.3.6.1.4.1.1570.1.6.4.1.7 |
frxUPerfTableThis table contains the U-interface Performance Monitoring
Statistics for each of the subscriber loops in the system
and for any BRITE cards extending those loops (e.g. using
Subscriber Loop Carrier systems) The table is indexed
first using the Cisco 90 Series channel bank digroup number,
then the channel unit number (1 to 24), then the port number
(0, 1, etc) and finally the location number (the BRITE card
number (1 to 6) or 7 for local parameters in the Cisco 90
Series card). These registers are defined by Bellcore
TR-TSY-000829. SEQUENCE OF FrxUPerfEntry .1.3.6.1.4.1.1570.1.6.5 |
frxUPerfEntryA specific entry in the U-interface Performance Monitoring
Statistics table. There is one entry for each port on each
Cisco 90 Series channel unit in the system and one entry for
each BRITE card extending those ports. There are no entries for
unused banks or empty channel unit slots FrxUPerfEntry .1.3.6.1.4.1.1570.1.6.5.1 |
frxResetPMReset all of the performance monitoring statistics on the
specified Cisco 90 Series channel unit or BRITE card.
1=Normal. 2=Reset. There is no need to set this register
back to Normal after doing a reset.rw Enumeration .1.3.6.1.4.1.1570.1.6.5.1.1 |
frxPMtypeDetermines if the Cisco 90 Series channel unit or the downstream
BRITE cards is doing segmented or path performance monitoring as
specified in Bellcore document TR-NWT-000397. Only segmented
performance monitoring should be used. In segmented PM, CRC
errors are counted on each segment of the loop, instead of
over the entire path. If no BRITE cards exist in the system,
there is no difference between segmented and path PM
1=Segmented. 2=Path.ro Enumeration .1.3.6.1.4.1.1570.1.6.5.1.2 |
frxChEsTxCurrent Hour Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.3 |
frxChEsRxCurrent Hour Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.4 |
frxPhEsTxPrevious Hour Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.5 |
frxPhEsRxPrevious Hour Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.6 |
frxH2EsTxErrored Seconds 2 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.7 |
frxH2EsRxErrored Seconds 2 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.8 |
frxH3EsTxErrored Seconds 3 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.9 |
frxH3EsRxErrored Seconds 3 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.10 |
frxH4EsTxErrored Seconds 4 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.11 |
frxH4EsRxErrored Seconds 4 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.12 |
frxH5EsTxErrored Seconds 5 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.13 |
frxH5EsRxErrored Seconds 5 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.14 |
frxH6EsTxErrored Seconds 6 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.15 |
frxH6EsRxErrored Seconds 6 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.16 |
frxH7EsTxErrored Seconds 7 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.17 |
frxH7EsRxErrored Seconds 7 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.18 |
frxH8EsTxErrored Seconds 8 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.19 |
frxH8EsRxErrored Seconds 8 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.20 |
frxCdEsTxCurrent Day Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.21 |
frxCdEsRxCurrent Day Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.22 |
frxPdEsTxPrevious Day Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.23 |
frxPdEsRxPrevious Day Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.24 |
frxChSesTxCurrent Hour Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.25 |
frxChSesRxCurrent Hour Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.26 |
frxPhSesTxPrevious Hour Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)ro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.27 |
frxPhSesRxPrevious Hour Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.28 |
frxCdSesTxCurrent Day Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.29 |
frxCdSesRxCurrent Day Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.30 |
frxPdSesTxPrevious Day Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.31 |
frxPdSesRxPrevious Day Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.32 |
frxChBeTxCurrent Hour Block Errors - Transmit direction.
Transmit is data from the network towards the customer.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.33 |
frxChBeRxCurrent Hour Block Errors - Receive direction.
Receive is data from the customer towards the network.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.34 |
frxPhBeTxPrevious Hour Block Errors - Transmit direction.
Transmit is data from the network towards the customer.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.35 |
frxPhBeRxPrevious Hour Block Errors - Receive direction.
Receive is data from the customer towards the network.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Addressro INTEGER .1.3.6.1.4.1.1570.1.6.5.1.36 |