Home/Catalog/ChrComIfOpticsOMS-SRC-MIB

ChrComIfOpticsOMS-SRC-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

40
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

40 total
Object Name
IMPORTSThe OMS is managed only for the Ring side of the Metropolis Network (not for the Trib side).
SEQUENCE OF ChrComIfOpticsOMS-SRCEntry
.1.3.6.1.4.1.3695.1.2.3.4
chrComIfOpticsOMS-SRCEntry
ChrComIfOpticsOMS-SRCEntry
.chrComIfOpticsOMS-SRCTable.1
chrComIfOpticsOmsSrcNumOfPrecedingOPAsNumber of OPAs prior to the respective ADOM/OMDM.rw
Integer32 (-1..32)
.chrComIfOpticsOMS-SRCTable.1.1
chrComIfOpticsOmsSrcDWDMOutputPowerThe optical power in the DWDM band (without the 1310nm channel) at the output of the module.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.2
chrComIfOpticsOmsSrcDWDMLOOPThrThis is a threshold on OMS-SRC DWDM output Power, indicating the existence of power in the DWDM band at the output of the module.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.3
chrComIfOpticsOmsSrcDWDMSafetyThrThis is a threshold on OMS-SRC DWDM output Power, indicating the safety power level in the DWDM band at the output of the ADOM/OMDM.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.4
chrComIfOpticsOmsSrcTx1310PowerThe optical power monitored on 1310 transmit point.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.5
chrComIfOpticsOmsSrcTxLambdaPowerThe optical power monitored on Lambda transmit point.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.6
chrComIfOpticsOmsSrcADOMPwrControlModeDefines ADOM module operational mode.rw
OMSControlType
.chrComIfOpticsOMS-SRCTable.1.7
chrComIfOpticsOmsSrcExpectedAddedLambdaPowerThe expected added Lambda channel power after Attenuation (reflected to module out).rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.8
chrComIfOpticsOmsSrcActualAddedPowerMonitored added lambda channel power after Attenuation (reflected to module out).ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.9
chrComIfOpticsOmsSrcExpectedAddedLambdaPowerOffsetThe expected added to dropped lambda channel power offset.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.10
chrComIfOpticsOmsSrcActualAddedPowerOffsetThe Actual added to dropped lambda channel power offset.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.11
chrComIfOpticsOmsSrcExpectedAddedChannelAttenuationThe expected Attenuation of added lambda channelrw
Integer32 (-1..400)
.chrComIfOpticsOMS-SRCTable.1.12
chrComIfOpticsOmsSrcActualAddedChannelAttenuationro
Integer32 (-1..400)
.chrComIfOpticsOMS-SRCTable.1.13
chrComIfOpticsOmsSrcBackplaneAttenuatorLambdaAttenuation in dB. Zero when no backplane Attenuator exists.rw
OCTET STRING
.chrComIfOpticsOMS-SRCTable.1.14
chrComIfOpticsOmsSrcBackplaneAttenuator1310Attenuation in dB. Zero when no backplane Attenuator exists.rw
Integer32 (-1..350)
.chrComIfOpticsOMS-SRCTable.1.15
chrComIfOpticsOmsSrcTxLambdaLOOCThrLooc Threshold of transmitted lambda power.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.16
chrComIfOpticsOmsSrcOCHSLOOCThrLambdaA duplication of the OCH-S Looc Threshold.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.17
chrComIfOpticsOmsSrcAddedLambdaLOOCThrLooc Threshold of added lambda.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.18
chrComIfOpticsOmsSrcTx1310LOOCThrLooc Threshold of transmitted 1310.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.19
chrComIfOpticsOmsSrcOCHSLOOCThr1310A duplication of the OCH-S Looc Threshold.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.20
chrComIfOpticsOmsSrcPostOPADWDMInputPowerThe optical power in the DWDM band (without the 1310nm channel) at the input of the pre-OPA.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.21
chrComIfOpticsOmsSrcPostOPAInputLOOCThrThis is a threshold on OMS-SRC post-OPA DWDM input Power, indicating Loss Of Optical DWDM Channels at the input to the Post-OPA.ro
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.22
chrComIfOpticsOmsSrcParamForPostOPAInputLOOCThrInput parameter for calculating OMS-SRC post-OPA input LOOC threshold.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.23
chrComIfOpticsOmsSrcPostOPAInputLOOPThrThis is a threshold on OMS-SRC post-OPA DWDM input Power, indicating Loss Of Optical DWDM power at the input to the Post-OPA.rw
Integer32 (-501..300)
.chrComIfOpticsOMS-SRCTable.1.24
chrComIfOpticsOmsSrcPostOPAModeOfOperation(Automatic Gain Control AGC  Default) Automatic Pump Power Control  PPCrw
Agcppc
.chrComIfOpticsOMS-SRCTable.1.25
chrComIfOpticsOmsSrcPostOPAExpectedGainThe Desired gain of the post OPA module (input to output optical DWDM power).rw
Integer32 (-1..350)
.chrComIfOpticsOMS-SRCTable.1.26
chrComIfOpticsOmsSrcPostOPAActualGainThe Actual gain of the post OPA (input to output optical DWDM power).ro
Integer32 (-1..350)
.chrComIfOpticsOMS-SRCTable.1.27
chrComIfOpticsOmsSrcPostOPAExpectedPumpPowerThe Desired EDFA pump power of post-OPA module.rw
Integer32 (-1..2000)
.chrComIfOpticsOMS-SRCTable.1.28
chrComIfOpticsOmsSrcPostOPAActualPumpPowerThe Actual EDFA pump power of post-OPA module.ro
Integer32 (-1..2000)
.chrComIfOpticsOMS-SRCTable.1.29
chrComIfOpticsOmsSrcPostOPAAPSDStateControlling the Automatic Pump Shut Down (APSD) mode.rw
APSDSTATE
.chrComIfOpticsOMS-SRCTable.1.30
chrComIfOpticsOmsSrcPostOPAPumpRestartActionEnables remote operation which is equivalent to the restart push button of the post-OPA.rw
TruthValue (SNMPv2-TC)
.chrComIfOpticsOMS-SRCTable.1.31
chrComIfOpticsOmsSrcPostOPAPumpLaserActivationStatusPost OPA Pump Laser ON/OFF Actual status.ro
LaserActivation
.chrComIfOpticsOMS-SRCTable.1.32
chrComIfOpticsOmsSrcOPAExpectedAttenuatorAttenuationThe expected Attenuation of the attenuator at the output of the OPArw
Integer32 (-1..400)
.chrComIfOpticsOMS-SRCTable.1.33
chrComIfOpticsOmsSrcOPAActualAttenuatorAttenuationThe actual Attenuation of the attenuator at the output of the OPAro
Integer32 (-1..400)
.chrComIfOpticsOMS-SRCTable.1.34
chrComIfOpticsOmsSrcPostOPAPumpTempThe temperature of the module.ro
Unsigned32
.chrComIfOpticsOMS-SRCTable.1.35
chrComIfOpticsOmsSrcPostOPAPumpBiasCurrentro
Integer32 (-1..4000)
.chrComIfOpticsOMS-SRCTable.1.36
chrComIfOpticsAlarmVectorro
Integer32
.chrComIfOpticsOMS-SRCTable.1.37
chrComIfOpticsAlarmSeverityProfileIndexrw
Unsigned32
.chrComIfOpticsOMS-SRCTable.1.38
ChrComIfOpticsOMS-SRC-MIB - SNMP MIB Reference | MIBs Explorer