ChrComIfOpticsOMS-SRC-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
40
Objects
Active
Status
8
Dependencies
Imported Objects
Objects
40 total| Object Name |
|---|
IMPORTSThe OMS is managed only for the Ring side of the Metropolis Network (not for the Trib side). SEQUENCE OF ChrComIfOpticsOMS-SRCEntry .1.3.6.1.4.1.3695.1.2.3.4 |
chrComIfOpticsOMS-SRCEntry ChrComIfOpticsOMS-SRCEntry .chrComIfOpticsOMS-SRCTable.1 |
chrComIfOpticsOmsSrcNumOfPrecedingOPAsNumber of OPAs prior to the respective ADOM/OMDM.rw Integer32 (-1..32) .chrComIfOpticsOMS-SRCTable.1.1 |
chrComIfOpticsOmsSrcDWDMOutputPowerThe optical power in the DWDM band (without the 1310nm channel) at the output of the module.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.2 |
chrComIfOpticsOmsSrcDWDMLOOPThrThis is a threshold on OMS-SRC DWDM output Power, indicating the existence of power in the DWDM band at the output of the module.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.3 |
chrComIfOpticsOmsSrcDWDMSafetyThrThis is a threshold on OMS-SRC DWDM output Power, indicating the safety power level in the DWDM band at the output of the ADOM/OMDM.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.4 |
chrComIfOpticsOmsSrcTx1310PowerThe optical power monitored on 1310 transmit point.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.5 |
chrComIfOpticsOmsSrcTxLambdaPowerThe optical power monitored on Lambda transmit point.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.6 |
chrComIfOpticsOmsSrcADOMPwrControlModeDefines ADOM module operational mode.rw OMSControlType .chrComIfOpticsOMS-SRCTable.1.7 |
chrComIfOpticsOmsSrcExpectedAddedLambdaPowerThe expected added Lambda channel power after Attenuation (reflected to module out).rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.8 |
chrComIfOpticsOmsSrcActualAddedPowerMonitored added lambda channel power after Attenuation (reflected to module out).ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.9 |
chrComIfOpticsOmsSrcExpectedAddedLambdaPowerOffsetThe expected added to dropped lambda channel power offset.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.10 |
chrComIfOpticsOmsSrcActualAddedPowerOffsetThe Actual added to dropped lambda channel power offset.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.11 |
chrComIfOpticsOmsSrcExpectedAddedChannelAttenuationThe expected Attenuation of added lambda channelrw Integer32 (-1..400) .chrComIfOpticsOMS-SRCTable.1.12 |
chrComIfOpticsOmsSrcActualAddedChannelAttenuationro Integer32 (-1..400) .chrComIfOpticsOMS-SRCTable.1.13 |
chrComIfOpticsOmsSrcBackplaneAttenuatorLambdaAttenuation in dB.
Zero when no backplane Attenuator exists.rw OCTET STRING .chrComIfOpticsOMS-SRCTable.1.14 |
chrComIfOpticsOmsSrcBackplaneAttenuator1310Attenuation in dB.
Zero when no backplane Attenuator exists.rw Integer32 (-1..350) .chrComIfOpticsOMS-SRCTable.1.15 |
chrComIfOpticsOmsSrcTxLambdaLOOCThrLooc Threshold of transmitted lambda power.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.16 |
chrComIfOpticsOmsSrcOCHSLOOCThrLambdaA duplication of the OCH-S Looc Threshold.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.17 |
chrComIfOpticsOmsSrcAddedLambdaLOOCThrLooc Threshold of added lambda.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.18 |
chrComIfOpticsOmsSrcTx1310LOOCThrLooc Threshold of transmitted 1310.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.19 |
chrComIfOpticsOmsSrcOCHSLOOCThr1310A duplication of the OCH-S Looc Threshold.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.20 |
chrComIfOpticsOmsSrcPostOPADWDMInputPowerThe optical power in the DWDM band (without the 1310nm channel) at the input of the pre-OPA.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.21 |
chrComIfOpticsOmsSrcPostOPAInputLOOCThrThis is a threshold on OMS-SRC post-OPA DWDM input Power, indicating Loss Of Optical DWDM Channels at the input to the Post-OPA.ro Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.22 |
chrComIfOpticsOmsSrcParamForPostOPAInputLOOCThrInput parameter for calculating OMS-SRC post-OPA input LOOC threshold.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.23 |
chrComIfOpticsOmsSrcPostOPAInputLOOPThrThis is a threshold on OMS-SRC post-OPA DWDM input Power, indicating Loss Of Optical DWDM power at the input to the Post-OPA.rw Integer32 (-501..300) .chrComIfOpticsOMS-SRCTable.1.24 |
chrComIfOpticsOmsSrcPostOPAModeOfOperation(Automatic Gain Control AGC Default)
Automatic Pump Power Control PPCrw Agcppc .chrComIfOpticsOMS-SRCTable.1.25 |
chrComIfOpticsOmsSrcPostOPAExpectedGainThe Desired gain of the post OPA module (input to output optical DWDM power).rw Integer32 (-1..350) .chrComIfOpticsOMS-SRCTable.1.26 |
chrComIfOpticsOmsSrcPostOPAActualGainThe Actual gain of the post OPA (input to output optical DWDM power).ro Integer32 (-1..350) .chrComIfOpticsOMS-SRCTable.1.27 |
chrComIfOpticsOmsSrcPostOPAExpectedPumpPowerThe Desired EDFA pump power of post-OPA module.rw Integer32 (-1..2000) .chrComIfOpticsOMS-SRCTable.1.28 |
chrComIfOpticsOmsSrcPostOPAActualPumpPowerThe Actual EDFA pump power of post-OPA module.ro Integer32 (-1..2000) .chrComIfOpticsOMS-SRCTable.1.29 |
chrComIfOpticsOmsSrcPostOPAAPSDStateControlling the Automatic Pump Shut Down (APSD) mode.rw APSDSTATE .chrComIfOpticsOMS-SRCTable.1.30 |
chrComIfOpticsOmsSrcPostOPAPumpRestartActionEnables remote operation which is equivalent to the restart push button of the post-OPA.rw TruthValue (SNMPv2-TC) .chrComIfOpticsOMS-SRCTable.1.31 |
chrComIfOpticsOmsSrcPostOPAPumpLaserActivationStatusPost OPA Pump Laser ON/OFF Actual status.ro LaserActivation .chrComIfOpticsOMS-SRCTable.1.32 |
chrComIfOpticsOmsSrcOPAExpectedAttenuatorAttenuationThe expected Attenuation of the attenuator at the output of the OPArw Integer32 (-1..400) .chrComIfOpticsOMS-SRCTable.1.33 |
chrComIfOpticsOmsSrcOPAActualAttenuatorAttenuationThe actual Attenuation of the attenuator at the output of the OPAro Integer32 (-1..400) .chrComIfOpticsOMS-SRCTable.1.34 |
chrComIfOpticsOmsSrcPostOPAPumpTempThe temperature of the module.ro Unsigned32 .chrComIfOpticsOMS-SRCTable.1.35 |
chrComIfOpticsOmsSrcPostOPAPumpBiasCurrentro Integer32 (-1..4000) .chrComIfOpticsOMS-SRCTable.1.36 |
chrComIfOpticsAlarmVectorro Integer32 .chrComIfOpticsOMS-SRCTable.1.37 |
chrComIfOpticsAlarmSeverityProfileIndexrw Unsigned32 .chrComIfOpticsOMS-SRCTable.1.38 |
More MIBs from Chromatis
Browse all ChromatisMIBs →Chromatis-MIB
The Chromatis-MIB module facilitates SNMP-based monitoring and management of Chromatis Networks' Metrpolis traffic analysis and reporting appliances. It exposes performance metrics including traffic flow statistics, session counts, protocol distribution, and system resource utilization specific to the Metrpolis platform.
39 objects→
ChrComIfOpticsOMS-SNK-MIB
Standard SNMP MIB module defining data structures for ChrComIfOpticsOMS-SNK-MIB.
32 objects→
ChrComHWEquipment-MIB
SNMP MIB module
28 objects→
ChrComPmEthETH-Day-MIB
Standard SNMP MIB module defining data structures for ChrComPmEthETH-Day-MIB.
27 objects→
ChrComPmEthETH-Interval-MIB
Standard SNMP MIB module defining data structures for ChrComPmEthETH-Interval-MIB.
26 objects→
ChrComPmEthETH-Current-MIB
SNMP MIB module
26 objects→