CPQHLTH-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
345
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
345 total| Object Name |
|---|
cpqHe2CorrectableMemoryErrorA correctable memory error occurred.
The error has been corrected. The current number of correctable
memory errors is reported in the variable cpqHeCorrMemTotalErrs. TRAP-TYPE .1.3.6.1.4.1.232.0.6001 |
cpqHe2CorrectableMemoryLogDisabledCorrectable memory error tracking disabled.
The frequency of errors is so high that the error tracking
logic has been temporarily disabled. The cpqHeCorrMemLogStatus
variable indicated the current tracking status. TRAP-TYPE .1.3.6.1.4.1.232.0.6002 |
cpqHeThermalTempFailedThe temperature status has been set to failed.
The system will be shutdown due to this thermal condition. TRAP-TYPE .1.3.6.1.4.1.232.0.6003 |
cpqHeThermalTempDegradedThe temperature status has been set to degraded.
The server's temperature is outside of the normal operating
range. The server will be shutdown if the
cpqHeThermalDegradedAction variable is set to shutdown(3). TRAP-TYPE .1.3.6.1.4.1.232.0.6004 |
cpqHeThermalTempOkThe temperature status has been set to ok.
The server's temperature has returned to the normal operating
range. TRAP-TYPE .1.3.6.1.4.1.232.0.6005 |
cpqHeThermalSystemFanFailedThe system fan status has been set to failed.
A required system fan is not operating normally. The system
will be shutdown if the cpqHeThermalDegradedAction variable
is set to shutdown(3). TRAP-TYPE .1.3.6.1.4.1.232.0.6006 |
cpqHeThermalSystemFanDegradedThe system fan status has been set to degraded.
An optional system fan is not operating normally. TRAP-TYPE .1.3.6.1.4.1.232.0.6007 |
cpqHeThermalSystemFanOkThe system fan status has been set to ok.
Any previously non-operational system fans have returned to
normal operation. TRAP-TYPE .1.3.6.1.4.1.232.0.6008 |
cpqHeThermalCpuFanFailedThe CPU fan status has been set to failed.
A processor fan is not operating normally. The server will be
shutdown. TRAP-TYPE .1.3.6.1.4.1.232.0.6009 |
cpqHeThermalCpuFanOkThe CPU fan status has been set to ok.
Any previously non-operational processor fans have returned
to normal operation. TRAP-TYPE .1.3.6.1.4.1.232.0.6010 |
cpqHeAsrConfirmationThe server is operational again.
The server has previously been shutdown by the
Automatic Server Recovery (ASR) feature and has just
become operational again. TRAP-TYPE .1.3.6.1.4.1.232.0.6011 |
cpqHeThermalConfirmationThe server is operational again.
The server has previously been shutdown due to a thermal
anomaly on the server and has just become operational again. TRAP-TYPE .1.3.6.1.4.1.232.0.6012 |
cpqHePostErrorOne or more POST errors occurred.
Power On Self-Test (POST) errors occur during the server
restart process. TRAP-TYPE .1.3.6.1.4.1.232.0.6013 |
cpqHeFltTolPwrSupplyDegradedThe fault tolerant power supply sub-system condition has been
set to degraded. TRAP-TYPE .1.3.6.1.4.1.232.0.6014 |
cpqHe3CorrectableMemoryErrorA correctable memory error occurred.
The error has been corrected. The current number of correctable
memory errors is reported in the variable cpqHeCorrMemTotalErrs. TRAP-TYPE .1.3.6.1.4.1.232.0.6015 |
cpqHe3CorrectableMemoryLogDisabledCorrectable memory error tracking disabled.
The frequency of errors is so high that the error tracking
logic has been temporarily disabled. The cpqHeCorrMemLogStatus
variable indicated the current tracking status. TRAP-TYPE .1.3.6.1.4.1.232.0.6016 |
cpqHe3ThermalTempFailedThe temperature status has been set to failed.
The system will be shutdown due to this thermal condition. TRAP-TYPE .1.3.6.1.4.1.232.0.6017 |
cpqHe3ThermalTempDegradedThe temperature status has been set to degraded.
The server's temperature is outside of the normal operating
range. The server will be shutdown if the
cpqHeThermalDegradedAction variable is set to shutdown(3). TRAP-TYPE .1.3.6.1.4.1.232.0.6018 |
cpqHe3ThermalTempOkThe temperature status has been set to ok.
The server's temperature has returned to the normal operating
range. TRAP-TYPE .1.3.6.1.4.1.232.0.6019 |
cpqHe3ThermalSystemFanFailedThe system fan status has been set to failed.
A required system fan is not operating normally. The system
will be shutdown if the cpqHeThermalDegradedAction variable
is set to shutdown(3). TRAP-TYPE .1.3.6.1.4.1.232.0.6020 |
cpqHe3ThermalSystemFanDegradedThe system fan status has been set to degraded.
An optional system fan is not operating normally. TRAP-TYPE .1.3.6.1.4.1.232.0.6021 |
cpqHe3ThermalSystemFanOkThe system fan status has been set to ok.
Any previously non-operational system fans have returned to
normal operation. TRAP-TYPE .1.3.6.1.4.1.232.0.6022 |
cpqHe3ThermalCpuFanFailedThe CPU fan status has been set to failed.
A processor fan is not operating normally. The server will be
shutdown. TRAP-TYPE .1.3.6.1.4.1.232.0.6023 |
cpqHe3ThermalCpuFanOkThe CPU fan status has been set to ok.
Any previously non-operational processor fans have returned
to normal operation. TRAP-TYPE .1.3.6.1.4.1.232.0.6024 |
cpqHe3AsrConfirmationThe server is operational again.
The server has previously been shutdown by the
Automatic Server Recovery (ASR) feature and has just
become operational again. TRAP-TYPE .1.3.6.1.4.1.232.0.6025 |
cpqHe3ThermalConfirmationThe server is operational again.
The server has previously been shutdown due to a thermal
anomaly on the server and has just become operational again. TRAP-TYPE .1.3.6.1.4.1.232.0.6026 |
cpqHe3PostErrorOne or more POST errors occurred.
Power On Self-Test (POST) errors occur during the server
restart process. Details of the POST error messages can
be found in Integrated Management Log TRAP-TYPE .1.3.6.1.4.1.232.0.6027 |
cpqHe3FltTolPwrSupplyDegradedThe fault tolerant power supply sub-system condition has been
set to degraded. TRAP-TYPE .1.3.6.1.4.1.232.0.6028 |
cpqHe3CorrMemReplaceMemModuleA correctable memory log entry indicates a memory module needs
to be replaced.
The errors have been corrected, but the memory module should be
replaced. The error information is reported in the variable
cpqHeCorrMemErrDesc. TRAP-TYPE .1.3.6.1.4.1.232.0.6029 |
cpqHe3FltTolPowerSupplyDegradedThe fault tolerant power supply condition has been set
to degraded for the specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6030 |
cpqHe3FltTolPowerSupplyFailedThe fault tolerant power supply condition has been set
to failed for the specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6031 |
cpqHe3FltTolPowerRedundancyLostThe Fault Tolerant Power Supplies have lost redundancy for
the specified chassis. TRAP-TYPE .1.3.6.1.4.1.232.0.6032 |
cpqHe3FltTolPowerSupplyInsertedA Fault Tolerant Power Supply has been inserted into the
specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6033 |
cpqHe3FltTolPowerSupplyRemovedA Fault Tolerant Power Supply has been removed from the
specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6034 |
cpqHe3FltTolFanDegradedThe Fault Tolerant Fan condition has been set to degraded
for the specified chassis and fan. TRAP-TYPE .1.3.6.1.4.1.232.0.6035 |
cpqHe3FltTolFanFailedThe Fault Tolerant Fan condition has been set to failed
for the specified chassis and fan. TRAP-TYPE .1.3.6.1.4.1.232.0.6036 |
cpqHe3FltTolFanRedundancyLostThe Fault Tolerant Fans have lost redundancy for the
specified chassis. TRAP-TYPE .1.3.6.1.4.1.232.0.6037 |
cpqHe3FltTolFanInsertedA Fault Tolerant Fan has been inserted into the specified
chassis and fan location. TRAP-TYPE .1.3.6.1.4.1.232.0.6038 |
cpqHe3FltTolFanRemovedA Fault Tolerant Fan has been removed from the specified
chassis and fan location. TRAP-TYPE .1.3.6.1.4.1.232.0.6039 |
cpqHe3TemperatureFailedThe temperature status has been set to failed in the
specified chassis and location.
The system will be shutdown due to this condition. TRAP-TYPE .1.3.6.1.4.1.232.0.6040 |
cpqHe3TemperatureDegradedThe temperature status has been set to degraded in the
specified chassis and location.
The server's temperature is outside of the normal operating
range. The server will be shutdown if the
cpqHeThermalDegradedAction variable is set to shutdown(3). TRAP-TYPE .1.3.6.1.4.1.232.0.6041 |
cpqHe3TemperatureOkThe temperature status has been set to ok in the
specified chassis and location.
The server's temperature has returned to the normal operating
range. TRAP-TYPE .1.3.6.1.4.1.232.0.6042 |
cpqHe3PowerConverterDegradedThe DC-DC Power Converter condition has been set to degraded
for the specified chassis, slot and socket. TRAP-TYPE .1.3.6.1.4.1.232.0.6043 |
cpqHe3PowerConverterFailedThe DC-DC Power Converter condition has been set to failed
for the specified chassis, slot and socket. TRAP-TYPE .1.3.6.1.4.1.232.0.6044 |
cpqHe3PowerConverterRedundancyLostThe DC-DC Power Converters have lost redundancy for the
specified chassis. TRAP-TYPE .1.3.6.1.4.1.232.0.6045 |
cpqHe3CacheAccelParityErrorA cache accelerator parity error indicates a cache module
needs to be replaced.
The error information is reported in the variable
cpqHeEventLogErrorDesc. TRAP-TYPE .1.3.6.1.4.1.232.0.6046 |
cpqHeResilientMemOnlineSpareEngagedAdvanced Memory Protection Online Spare Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. The Online Spare Memory has been activated.
User Action: Schedule server down-time to replace the faulty
memory. TRAP-TYPE .1.3.6.1.4.1.232.0.6047 |
cpqHe4FltTolPowerSupplyOkThe fault tolerant power supply condition has been set back
to the OK state for the specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6048 |
cpqHe4FltTolPowerSupplyDegradedThe fault tolerant power supply condition has been set
to degraded for the specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6049 |
cpqHe4FltTolPowerSupplyFailedThe fault tolerant power supply condition has been set
to failed for the specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6050 |
cpqHeResilientMemMirroredMemoryEngagedAdvanced Memory Protection Mirrored Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. Mirrored Memory has been activated.
User Action: Replace the faulty memory. TRAP-TYPE .1.3.6.1.4.1.232.0.6051 |
cpqHeResilientAdvancedECCMemoryEngagedAdvanced Memory Protection Advanced ECC Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. Advanced ECC has been activated.
User Action: Replace the faulty memory. TRAP-TYPE .1.3.6.1.4.1.232.0.6052 |
cpqHeResilientMemXorMemoryEngagedAdvanced Memory Protection XOR Engine Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. The XOR engine has been activated.
User Action: Replace the faulty memory. TRAP-TYPE .1.3.6.1.4.1.232.0.6053 |
cpqHe3FltTolPowerRedundancyRestoredThe Fault Tolerant Power Supplies have returned to a redundant
state for the specified chassis. TRAP-TYPE .1.3.6.1.4.1.232.0.6054 |
cpqHe3FltTolFanRedundancyRestoredThe Fault Tolerant Fans have returned to a redundant state for
the specified chassis. TRAP-TYPE .1.3.6.1.4.1.232.0.6055 |
cpqHe4CorrMemReplaceMemModuleCorrected Memory Errors Detected
The errors have been corrected, but the memory module should be
replaced. TRAP-TYPE .1.3.6.1.4.1.232.0.6056 |
cpqHeResMemBoardRemovedMemory board or cartridge removed.
An Advanced Memory Protection sub-system board or cartridge has
been removed from the system.
User Action: Insure the board or cartridge has memory correctly
installed and re-insert the memory board or cartridge back into
the system. TRAP-TYPE .1.3.6.1.4.1.232.0.6057 |
cpqHeResMemBoardInsertedMemory board or cartridge inserted.
An Advanced Memory Protection sub-system board or cartridge has
been inserted into the system.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.6058 |
cpqHeResMemBoardBusErrorMemory board or cartridge bus error detected.
An Advanced Memory Protection sub-system board or cartridge
bus error has been detected.
User Action: Replace the indicated board or cartridge. TRAP-TYPE .1.3.6.1.4.1.232.0.6059 |
cpqHeEventOccurredAn event has occurred.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.6060 |
cpqHeManagementProcInResetThe Management processor is currently in reset
The management processor is currently in the process of being reset
because of a firmware update or some other event.
User action: None TRAP-TYPE .1.3.6.1.4.1.232.0.6061 |
cpqHeManagementProcReadyThe Management processor is ready
The management processor has successfully reset and is now available
again.
User action: None TRAP-TYPE .1.3.6.1.4.1.232.0.6062 |
cpqHeManagementProcFailedResetThe Management processor failed reset
The management processor was not successfully reset and is not
operational.
User action: Reset the management procesessor again or re-flash
the management processor firmware. TRAP-TYPE .1.3.6.1.4.1.232.0.6063 |
cpqHe5CorrMemReplaceMemModuleCorrected \ uncorrected Memory Errors Detected
The errors have been corrected, but the memory module should be
replaced. Value 0 for CPU means memory is not Processor based TRAP-TYPE .1.3.6.1.4.1.232.0.6064 |
cpqHe5ResMemBoardRemovedMemory board or cartridge or riser removed.
An Advanced Memory Protection sub-system board or cartridge or riser has
been removed from the system. Value 0 for CPU means memory is not processor based.
User Action: Insure the board or cartridge or riser has memory correctly
installed and re-insert the memory board or cartridge or CPU back into
the system. TRAP-TYPE .1.3.6.1.4.1.232.0.6065 |
cpqHe5ResMemBoardInsertedMemory board or cartridge or riser inserted.
An Advanced Memory Protection sub-system board or cartridge or riser
Has been inserted into the system. Value 0 for CPU means memory is not processor based.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.6066 |
cpqHe5ResMemBoardBusErrorMemory board or cartridge or Riser bus error detected.
An Advanced Memory Protection sub-system board or cartridge or Riser
bus error has been detected. Value 0 for CPU means memory is not processor based.
User Action: Replace the indicated board or cartridge or Riser. TRAP-TYPE .1.3.6.1.4.1.232.0.6067 |
cpqHeResilientMemLockStepMemoryEngagedAdvanced Memory Protection LockStep Engine Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. The LockStep engine has been activated.
User Action: Replace the faulty memory. TRAP-TYPE .1.3.6.1.4.1.232.0.6068 |
cpqHe4FltTolPowerSupplyACpowerlossThe fault tolerant power supply AC power loss for the specified chassis and bay location. TRAP-TYPE .1.3.6.1.4.1.232.0.6069 |
cpqHealth OBJECT IDENTIFIER .1.3.6.1.4.1.232.6 |
RFC1213-MIB Unknown .1.3.6.1.4.1.232.6 |
cpqHeCorrectableMemoryErrorA correctable memory error occurred.
The error has been corrected. The current number of correctable
memory errors is reported in the variable cpqHeCorrMemTotalErrs. TRAP-TYPE .1.3.6.1.4.1.232.6.0.1 |
cpqHeCorrectableMemoryLogDisabledCorrectable memory error tracking disabled.
The frequency of errors is so high that the error tracking
logic has been temporarily disabled. The cpqHeCorrMemLogStatus
variable indicated the current tracking status. TRAP-TYPE .1.3.6.1.4.1.232.6.0.2 |
cpqHeMibRev OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.1 |
cpqHeMibRevMajorThe Major Revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level.ro INTEGER .1.3.6.1.4.1.232.6.1.1 |
cpqHeMibRevMinorThe minor revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred.ro INTEGER .1.3.6.1.4.1.232.6.1.2 |
cpqHeMibConditionThe overall condition.
This object represents the overall status of the server health
system represented by this MIB.ro Enumeration .1.3.6.1.4.1.232.6.1.3 |
cpqHeComponent OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2 |
cpqHeInterface OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.1 |
cpqHeOsNetWare3x OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.1.1 |
cpqHeNw3xDriverNameDriver Name.
This value identifies the NetWare Loadable Module providing the
operating system access to the Server Health information.rodeprecated DisplayString .1.3.6.1.4.1.232.6.2.1.1.1 |
cpqHeNw3xDriverDateDriver Date.
The date of the NetWare Loadable Module providing the operating
system access to the Server Health logs. The date is
provided in mm/dd/yy format.rodeprecated DisplayString .1.3.6.1.4.1.232.6.2.1.1.2 |
cpqHeNw3xDriverVersionDriver Version.
This is the version of the NetWare Loadable Module (NLM)
providing the operating system access to the Server
Health logs.rodeprecated DisplayString .1.3.6.1.4.1.232.6.2.1.1.3 |
cpqHeOsCommon OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.1.4 |
cpqHeOsCommonPollFreqThe Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is 0 all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero will always
fail, an agent may also choose to fail any request to change
the poll frequency to a value that would severely impact system
performance.rw INTEGER .1.3.6.1.4.1.232.6.2.1.4.1 |
cpqHeOsCommonModuleTableSupporting software table.
This is a table of software modules that provide an interface
to the device this server health MIB describes.deprecated SEQUENCE OF CpqHeOsCommonModuleEntry .1.3.6.1.4.1.232.6.2.1.4.2 |
cpqHeOsCommonModuleEntryA description of a software modules that provide an interface
to the device this MIB describes.deprecated CpqHeOsCommonModuleEntry .1.3.6.1.4.1.232.6.2.1.4.2.1 |
cpqHeOsCommonModuleIndexA unique index for this module description.rodeprecated INTEGER .1.3.6.1.4.1.232.6.2.1.4.2.1.1 |
cpqHeOsCommonModuleNameThe module name.rodeprecated DisplayString .1.3.6.1.4.1.232.6.2.1.4.2.1.2 |
cpqHeOsCommonModuleVersionThe module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be null (size 0) string if the agent
cannot provide the module version.rodeprecated DisplayString .1.3.6.1.4.1.232.6.2.1.4.2.1.3 |
cpqHeOsCommonModuleDateThe module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first.rodeprecated OCTET STRING .1.3.6.1.4.1.232.6.2.1.4.2.1.4 |
cpqHeOsCommonModulePurposeThe purpose of the module described in this entry.rodeprecated DisplayString .1.3.6.1.4.1.232.6.2.1.4.2.1.5 |
cpqHeCriticalError OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.2 |
cpqHeCritLogSupportedThis value specifies if this system supports the critical
error logging feature.ro Enumeration .1.3.6.1.4.1.232.6.2.2.1 |
cpqHeCritLogConditionThis value specifies the overall condition of the critical
error log feature.ro Enumeration .1.3.6.1.4.1.232.6.2.2.2 |
cpqHeLastCritErrorAbendMsgLast Critical Termination message.
The message associated with the last critical error of
type criticalException(14) or abend(27).ro DisplayString .1.3.6.1.4.1.232.6.2.2.3 |
cpqHeCriticalErrorTableA table of critical error descriptions. SEQUENCE OF CpqHeCriticalErrorEntry .1.3.6.1.4.1.232.6.2.2.4 |
cpqHeCriticalErrorEntryA critical error description. CpqHeCriticalErrorEntry .1.3.6.1.4.1.232.6.2.2.4.1 |
cpqHeCriticalErrorIndexA number that uniquely specifies this critical error
description. The entries will be in order of occurrence
with the most recent entry first.ro INTEGER .1.3.6.1.4.1.232.6.2.2.4.1.1 |
cpqHeCriticalErrorStatusThis value specifies if the user has marked this error as
corrected. Marking errors as corrected may be performed with
the Diagnostics or by a set operation on this variable.
Attempting to set this variable to uncorrected(1) will fail.rw Enumeration .1.3.6.1.4.1.232.6.2.2.4.1.2 |
cpqHeCriticalErrorTypeThis value specifies the type of error.ro Enumeration .1.3.6.1.4.1.232.6.2.2.4.1.3 |
cpqHeCriticalErrorTimeThe time of the error: hour (first five bits), day of month
(next 5 bits), month (next 4 bits), year of the current century
(next 7 bits). The last 3 bits are reserved.ro OCTET STRING .1.3.6.1.4.1.232.6.2.2.4.1.4 |
cpqHeCriticalErrorInfoInformation about the error.ro OCTET STRING .1.3.6.1.4.1.232.6.2.2.4.1.5 |
cpqHeCriticalErrorDescA text description of the critical error.ro DisplayString .1.3.6.1.4.1.232.6.2.2.4.1.6 |
cpqHeCorrectableMemory OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.3 |
cpqHeCorrMemLogStatusThis value specifies whether this system is currently tracking
correctable memory errors.ro Enumeration .1.3.6.1.4.1.232.6.2.3.1 |
cpqHeCorrMemLogConditionThis value specifies the overall condition of the correctable
memory error log feature.ro Enumeration .1.3.6.1.4.1.232.6.2.3.2 |
cpqHeCorrMemTotalErrsThe number of correctable memory errors that have occurred.rodeprecated INTEGER .1.3.6.1.4.1.232.6.2.3.3 |
cpqHeCorrMemErrTableA table of correctable memory error descriptions. SEQUENCE OF CpqHeCorrMemErrEntry .1.3.6.1.4.1.232.6.2.3.4 |
cpqHeCorrMemErrEntryA correctable memory error description. CpqHeCorrMemErrEntry .1.3.6.1.4.1.232.6.2.3.4.1 |
cpqHeCorrMemErrIndexA number that uniquely specifies this correctable memory error
description. The entries will be in order of occurrence with the
most recent new entry first.ro INTEGER .1.3.6.1.4.1.232.6.2.3.4.1.1 |
cpqHeCorrMemErrCountThe number of times this memory location has had a correctable
memory error. The value zero (0) indicates that the user has
marked this error as corrected. Marking errors as corrected may
be performed with the Diagnostics or with a set operation
of 0 on this variable. Any non-zero valued set operation will
fail.rw INTEGER .1.3.6.1.4.1.232.6.2.3.4.1.2 |
cpqHeCorrMemErrTimeThe time of the error: hour (first five bits), day of month
(next 5 bits), month (next 4 bits), year of the current century
(next 7 bits). The last 3 bits are reserved.ro OCTET STRING .1.3.6.1.4.1.232.6.2.3.4.1.3 |
cpqHeCorrMemErrDdrThe data destination register value.
This contains information about the memory bank in which the
error occurred. The interpretation of this value is dependent
on the machine type.ro OCTET STRING .1.3.6.1.4.1.232.6.2.3.4.1.4 |
cpqHeCorrMemErrSyndromeThe memory syndrome value.
This contains information about the memory module in which the
error occurred. The interpretation of this value is dependant
on the machine type.ro OCTET STRING .1.3.6.1.4.1.232.6.2.3.4.1.5 |
cpqHeCorrMemErrDescA text description of the correctable memory error.ro DisplayString .1.3.6.1.4.1.232.6.2.3.4.1.6 |
cpqHeCorrMemErrHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the correctable memory error.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.3.4.1.7 |
cpqHeCorrMemErrorCntThreshThe error threshold for Correctable memory errors. When
cpqHeCorrMemErrCount is greater than or equal to this value
user action is required to replace the failing memory module.ro INTEGER .1.3.6.1.4.1.232.6.2.3.5 |
cpqHeAsr OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.5 |
cpqHeAsrStatusThe Automatic Server Recovery feature status.
If this object is currently other(1) or notAvailable(2) all
set operations will fail. Any attempt to set this object to
other(1) or notAvailable(2) by a management station will fail.
Setting this object to disabled(3) or enabled(4) will disable
or enable the ASR feature.
Setting this object to disabled(3) will disable the following
objects:
cpqHeAsrPagerStatus
cpqHeAsrDialInStatus
cpqHeAsrDialOutStatusrw Enumeration .1.3.6.1.4.1.232.6.2.5.1 |
cpqHeAsrMajorVersionThe major version number of the Automatic Server Recovery
feature hardware.ro INTEGER .1.3.6.1.4.1.232.6.2.5.2 |
cpqHeAsrMinorVersionThe minor version number of the Automatic Server Recovery
feature hardware.ro INTEGER .1.3.6.1.4.1.232.6.2.5.3 |
cpqHeAsrTimeoutThe time-out in minutes for the Automatic Server Recovery
feature hardware. If the variable is not supported, a value
of -1 will be returned.rw INTEGER .1.3.6.1.4.1.232.6.2.5.4 |
cpqHeAsrBaseIoThe Automatic Server Recovery feature Base I/O address.ro INTEGER .1.3.6.1.4.1.232.6.2.5.5 |
cpqHeAsrPostIndicates if the Automatic Server Recovery timer passed
the server power-on self test.rodeprecated Enumeration .1.3.6.1.4.1.232.6.2.5.6 |
cpqHeAsrResetIndicates if the previous reset was caused by the ASR
timer. An asrReset(3) condition may be changed with a
viewed-asrReset(4) set operation. This is only valid
if this variable's current value is asrReset(3). Setting
this variable to any other value than viewed-asrReset(4)
will fail.rw Enumeration .1.3.6.1.4.1.232.6.2.5.7 |
cpqHeAsrRebootIndicates what software should be started when the server is
rebooted by the ASR feature.
If this object is currently set to other(1), set operations
will fail. This object may not be set to other(1) by a
management station.
Setting this object to bootOs(2) or bootUtilities(3)
will select the software to be started after an ASR reboot.rw Enumeration .1.3.6.1.4.1.232.6.2.5.8 |
cpqHeAsrRebootLimitThe number of ASR timer reboots that should cause the server to
boot the firmware console and override the standard reboot
setting (cpqHeAsrReboot). If this value is 0 then no limit is
defined and the standard reboot option will always be used. If
the variable is not supported, a value of -1 will be returned.rw INTEGER .1.3.6.1.4.1.232.6.2.5.9 |
cpqHeAsrRebootCountThe number of ASR reboots that have occurred on this server
since the last manual reboot. Reboot count may be reset with
a zero valued set operation on this variable. Setting this
value to a non-zero value will fail. If the variable is not
supported, a value of -1 will be returned.rw INTEGER .1.3.6.1.4.1.232.6.2.5.10 |
cpqHeAsrPagerStatusThe status of the ASR pager feature.
If the current value of this object is not other(1), it may
be set to disabled(2) or enabled(3). Attempting a set operation
while the value is other(1) will fail. Attempting to set the
value to other(1) will fail.
Setting this object to enabled(3) will enable the
cpqHeAsrStatus object.rw Enumeration .1.3.6.1.4.1.232.6.2.5.11 |
cpqHeAsrPagerNumberThe pager number to be dialed after an ASR reboot.rw DisplayString .1.3.6.1.4.1.232.6.2.5.12 |
cpqHeAsrCommPortThe communication port to be used by the firmware pager and
console. The value zero (0) indicates this setting is undefined.
If the current value of this object is zero (0) any
attempt to set this object from a management station
will fail. Any attempt to set this object to zero (0)
by a management station will fail. If the variable is not
supported, a value of -1 will be returned.rw INTEGER .1.3.6.1.4.1.232.6.2.5.13 |
cpqHeAsrBaudRateThe baud rate to be used by the firmware pager and console.
The value zero (0) indicates this setting is undefined. If the
variable is not supported, a value of -1 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.5.14 |
cpqHeAsrPagerMessageThe 8 character pager message entered by the user.rw DisplayString .1.3.6.1.4.1.232.6.2.5.15 |
cpqHeAsrBootFailThe action to be taken if an ASR reboot failure occurs.rodeprecated Enumeration .1.3.6.1.4.1.232.6.2.5.16 |
cpqHeAsrConditionThis value specifies the overall condition of the ASR feature.ro Enumeration .1.3.6.1.4.1.232.6.2.5.17 |
cpqHeAsrDialInStatusThe status of the ASR dial in feature.
If the current value of this object is other(1) any attempt to
set this object from a management station will fail. Any
attempt to set this object to other(1) by a management station
will fail.
Setting this object to enabled(3) will enable the
cpqHeAsrStatus object.rw Enumeration .1.3.6.1.4.1.232.6.2.5.18 |
cpqHeAsrDialOutStatusThe status of the ASR dial out feature.
If the current value of this object is other(1) any attempt to
set this object from a management station will fail. Any
attempt to set this object to other(1) by a management station
will fail.
Setting this object to enabled(3) will enable the
cpqHeAsrStatus and the cpqHeAsrDialInStatus objects.rw Enumeration .1.3.6.1.4.1.232.6.2.5.19 |
cpqHeAsrDialOutNumberThe phone number to be dialed for remote diagnostics if an ASR
reset occurs.rw DisplayString .1.3.6.1.4.1.232.6.2.5.20 |
cpqHeAsrNetworkAccessStatusThe status of the ASR network access feature.
If the current value of this object is other(1) any attempt to
set this object from a management station will fail. Any
attempt to set this object to other(1) by a management station
will fail.rw Enumeration .1.3.6.1.4.1.232.6.2.5.21 |
cpqHeAsrPollTimeThe poll time in seconds the ASR watchdog timer is being
refreshed periodically.rw INTEGER .1.3.6.1.4.1.232.6.2.5.22 |
cpqHeThermal OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.6 |
cpqHeThermalConditionThis value specifies the overall condition of the system's
thermal environment.ro Enumeration .1.3.6.1.4.1.232.6.2.6.1 |
cpqHeThermalDegradedActionThe action to perform when the thermal condition is degraded.
This value will be one of the following:
other(1)
This feature is not supported by this system or driver.
continue(2)
The system should be allowed to continue.
shutdown(3)
The system should be shutdown.rw Enumeration .1.3.6.1.4.1.232.6.2.6.2 |
cpqHeThermalTempStatusThe status of the system's temperature sensors:
This value will be one of the following:
other(1)
Temp sensing is not supported by this system or driver.
ok(2)
All temp sensors are within normal operating range.
degraded(3)
A temp sensor is outside of normal operating range.
failed(4)
A temp sensor detects a condition that could permanently
damage the system.
The system will automatically shutdown if the failed(4) condition
results, so it is unlikely that this value will ever be returned
by the agent. If the cpqHeThermalDegradedAction is set to
shutdown(3) the system will be shutdown if the degraded(3)
condition occurs.ro Enumeration .1.3.6.1.4.1.232.6.2.6.3 |
cpqHeThermalSystemFanStatusThe status of the fan(s) in the system.
This value will be one of the following:
other(1)
Fan status detection is not supported by this system or driver.
ok(2)
All fans are operating properly.
degraded(3)
A non-required fan is not operating properly.
failed(4)
A required fan is not operating properly.
If the cpqHeThermalDegradedAction is set to shutdown(3) the
system will be shutdown if the failed(4) condition occurs.ro Enumeration .1.3.6.1.4.1.232.6.2.6.4 |
cpqHeThermalCpuFanStatusThe status of the processor fan(s) in the system.
This value will be one of the following:
other(1)
Fan status detection is not supported by this system or driver.
ok(2)
All fans are operating properly.
failed(4)
A fan is not operating properly.
The system will be shutdown if the failed(4) condition occurs.ro Enumeration .1.3.6.1.4.1.232.6.2.6.5 |
cpqHeThermalFanTableA table of fan descriptions. SEQUENCE OF CpqHeThermalFanEntry .1.3.6.1.4.1.232.6.2.6.6 |
cpqHeThermalFanEntryA fan description. CpqHeThermalFanEntry .1.3.6.1.4.1.232.6.2.6.6.1 |
cpqHeThermalFanIndexA number that uniquely specifies this fan description.ro INTEGER .1.3.6.1.4.1.232.6.2.6.6.1.1 |
cpqHeThermalFanRequiredThis specifies if the fan described is required for proper
operation of the system.ro Enumeration .1.3.6.1.4.1.232.6.2.6.6.1.2 |
cpqHeThermalFanPresentThis specifies if the fan described is present in the system.ro Enumeration .1.3.6.1.4.1.232.6.2.6.6.1.3 |
cpqHeThermalFanCpuFanThis specifies if the described fan is intended specifically
to cool the CPU(s).ro Enumeration .1.3.6.1.4.1.232.6.2.6.6.1.4 |
cpqHeThermalFanStatusThis specifies if the fan described is operating properly.
This value will be one of the following:
other(1)
Fan status detection is not supported by this system or driver.
ok(2)
The fan is operating properly.
failed(4)
The fan is not operating properly.ro Enumeration .1.3.6.1.4.1.232.6.2.6.6.1.5 |
cpqHeThermalFanHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the fan.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.6.6.1.6 |
cpqHeThermalFanCurrentSpeedThe current speed of a fan in rpm - revolutions per minute.ro INTEGER .1.3.6.1.4.1.232.6.2.6.6.1.7 |
cpqHeFltTolFanTableA table of Fault Tolerant Fan Entries. SEQUENCE OF CpqHeFltTolFanEntry .1.3.6.1.4.1.232.6.2.6.7 |
cpqHeFltTolFanEntryA Fault Tolerant Fan Entry. CpqHeFltTolFanEntry .1.3.6.1.4.1.232.6.2.6.7.1 |
cpqHeFltTolFanChassisThe System Chassis number.ro INTEGER .1.3.6.1.4.1.232.6.2.6.7.1.1 |
cpqHeFltTolFanIndexA number that uniquely specifies this fan description.ro INTEGER .1.3.6.1.4.1.232.6.2.6.7.1.2 |
cpqHeFltTolFanLocaleThis specifies the location of the fan in the system.ro Enumeration .1.3.6.1.4.1.232.6.2.6.7.1.3 |
cpqHeFltTolFanPresentThis specifies if the fan described is present in the system.ro Enumeration .1.3.6.1.4.1.232.6.2.6.7.1.4 |
cpqHeFltTolFanTypeThis specifies the type of fan.
other(1)
The type of fan could not be determined.
tachOutput(2)
The fan can increase speed for greater cooling. Implies
spin detect.
spinDetect(3)
The fan can detect when the fan stops spinning.ro Enumeration .1.3.6.1.4.1.232.6.2.6.7.1.5 |
cpqHeFltTolFanSpeedThis specifies the speed of the fan. This value will be set
if the fan type is tachOutput.ro Enumeration .1.3.6.1.4.1.232.6.2.6.7.1.6 |
cpqHeFltTolFanRedundantThis specifies if the fan is in a redundant configuration.ro Enumeration .1.3.6.1.4.1.232.6.2.6.7.1.7 |
cpqHeFltTolFanRedundantPartnerThis specifies the index of the redundant partner. A value
of zero will be used if there is no redundant partner.ro INTEGER .1.3.6.1.4.1.232.6.2.6.7.1.8 |
cpqHeFltTolFanConditionThe condition of the fan.
This value will be one of the following:
other(1)
Fan status detection is not supported by this system or driver.
ok(2)
The fan is operating properly.
degraded(3)
A redundant fan is not operating properly.
failed(4)
A non-redundant fan is not operating properly.ro Enumeration .1.3.6.1.4.1.232.6.2.6.7.1.9 |
cpqHeFltTolFanHotPlugThis indicates if the fan is capable of being removed and/or
inserted while the system is in an operational state.
If the value is hotPluggable(3), the fan can be safely
removed if and only if the cpqHeFltTolFanRedundant
field is in a redundant(3) state.
This value will be one of the following:
other(1)
The state could not be determined.
nonHotPluggable(2)
The fan is not hot plug capable.
hotPluggable(3)
The fan is hot plug capable and can be removed if
the system is operating in a redundant state. A fan
may be added to an empty fan bay.ro Enumeration .1.3.6.1.4.1.232.6.2.6.7.1.10 |
cpqHeFltTolFanHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the fan.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.6.7.1.11 |
cpqHeFltTolFanCurrentSpeedThe current speed of a fan in rpm - revolutions per minute.ro INTEGER .1.3.6.1.4.1.232.6.2.6.7.1.12 |
cpqHeTemperatureTableA table of Temperature Sensor Entries. SEQUENCE OF CpqHeTemperatureEntry .1.3.6.1.4.1.232.6.2.6.8 |
cpqHeTemperatureEntryA Temperature Sensor Entry. CpqHeTemperatureEntry .1.3.6.1.4.1.232.6.2.6.8.1 |
cpqHeTemperatureChassisThe System Chassis number.ro INTEGER .1.3.6.1.4.1.232.6.2.6.8.1.1 |
cpqHeTemperatureIndexA number that uniquely specifies this temperature sensor
description.ro INTEGER .1.3.6.1.4.1.232.6.2.6.8.1.2 |
cpqHeTemperatureLocaleThis specifies the location of the temperature sensor
present in the system.ro Enumeration .1.3.6.1.4.1.232.6.2.6.8.1.3 |
cpqHeTemperatureCelsiusThis is the current temperature sensor reading in degrees
celsius.
If this value cannot be determined by software, then a value
of -99 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.6.8.1.4 |
cpqHeTemperatureThresholdThis is the shutdown threshold temperature sensor setting
in degrees celsius. This is the temperature in which the
sensor will be considered to be in a failed state thus
causing the system to be shutdown.
If this value cannot be determined by software, then a value
of -99 will be returned.
Only the Ambient zone type allows setting of the threshold
temperature.rw INTEGER .1.3.6.1.4.1.232.6.2.6.8.1.5 |
cpqHeTemperatureConditionThe Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition
results, so it is unlikely that this value will ever be returned
by the agent. If the cpqHeThermalDegradedAction is set to
shutdown(3) the system will be shutdown if the degraded(3)
condition occurs.ro Enumeration .1.3.6.1.4.1.232.6.2.6.8.1.6 |
cpqHeTemperatureThresholdTypeThis specifies the type of this instance of temperature
sensor.
This value will be one of the following:
other(1)
Temperature threshold type could not be determined.
blowout(5)
If a blowout(5) temperature sensor reaches its threshold,
the fan or fans in the area of the temperature sensor will
increase in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
caution(9)
If a caution(9) temperature sensor reaches its threshold,
the cpqHeTemperatureCondition will be set to degraded(3)
and the system will either continue or shutdown depending
on the setting of cpqHeThermalDegradedAction.
critical(15)
If a critical(15) temperature sensor reaches its threshold,
the cpqHeTemperatureCondition will be set to failed(4)
and the system will shutdown.
noreaction(16)
this value will be defined when a threshold value is zero and
system will not react on those sensor as those threshold
sensors are meant for display purpose only.ro Enumeration .1.3.6.1.4.1.232.6.2.6.8.1.7 |
cpqHeTemperatureHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the temperature sensor.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.6.8.1.8 |
cpqHePostMsg OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.7 |
cpqHePostMsgConditionThis value specifies the overall condition of the POST
error recording feature.ro Enumeration .1.3.6.1.4.1.232.6.2.7.1 |
cpqHePostMsgTableA table of POST error message numbers. SEQUENCE OF CpqHePostMsgEntry .1.3.6.1.4.1.232.6.2.7.2 |
cpqHePostMsgEntryA POST error message number. CpqHePostMsgEntry .1.3.6.1.4.1.232.6.2.7.2.1 |
cpqHePostMsgIndexA number that uniquely specifies this POST error description.ro INTEGER .1.3.6.1.4.1.232.6.2.7.2.1.1 |
cpqHePostMsgCodeThis specifies POST message number for this error.ro INTEGER .1.3.6.1.4.1.232.6.2.7.2.1.2 |
cpqHePostMsgDescThis contains a text description of the POST error.
A string of length zero (0) will be returned if no description
is available.ro DisplayString .1.3.6.1.4.1.232.6.2.7.2.1.3 |
cpqHePostMsgEvThe EV used to store 8 non-critical POST error codes
for use with Quicktest, Utilities, and CIM. Setting
this variable with a zero length octet string will
clear this variable. All other set operations will
fail.rw OCTET STRING .1.3.6.1.4.1.232.6.2.7.3 |
cpqHeSysUtil OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.8 |
cpqHeSysUtilLifeTimeThe total time (in minutes) the system has been in full
operation (while the server health supporting software was
running).ro INTEGER .1.3.6.1.4.1.232.6.2.8.1 |
cpqHeSysUtilEisaBusMinThe EISA bus utilization as a percentage of the theoretical
maximum during the last minute. A value of -1 indicates that
this feature is not supported on this machine or is not
available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.2 |
cpqHeSysUtilEisaBusFiveMinThe EISA bus utilization as a percentage of the theoretical
maximum during the last five minutes. A value of -1 indicates
that this feature is not supported on this machine or is not
available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.3 |
cpqHeSysUtilEisaBusThirtyMinThe EISA bus utilization as a percentage of the theoretical
maximum during the last thirty minutes. A value of -1
indicates that this feature is not supported on this machine
or is not available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.4 |
cpqHeSysUtilEisaBusHourThe EISA bus utilization as a percentage of the theoretical
maximum during the last hour. A value of -1 indicates that
this feature is not supported on this machine or is not
available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.5 |
cpqHeSysUtilPciTableA table of PCI utilization numbers for a whole aggregate
PCI bus or a specific device on that bus. SEQUENCE OF CpqHeSysUtilPciEntry .1.3.6.1.4.1.232.6.2.8.6 |
cpqHeSysUtilPciEntryPCI utilization entry CpqHeSysUtilPciEntry .1.3.6.1.4.1.232.6.2.8.6.1 |
cpqHeSysUtilPciIndexA unique index into each PCI utilization table entry.ro INTEGER .1.3.6.1.4.1.232.6.2.8.6.1.1 |
cpqHeSysUtilPciBusThe PCI bus number for this set of utilization numbers.ro INTEGER .1.3.6.1.4.1.232.6.2.8.6.1.2 |
cpqHeSysUtilPciDeviceThe PCI device number for this set of utilization numbers.
If this value is -1, the utilization reported is for the
aggregate of all devices on this PCI bus.ro INTEGER .1.3.6.1.4.1.232.6.2.8.6.1.3 |
cpqHeSysUtilPciMinThe utilization as a percentage of the theoretical
maximum during the last minute. A value of -1 indicates
that the utilization number is not available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.6.1.4 |
cpqHeSysUtilPciFiveMinThe utilization as a percentage of the theoretical
maximum during the last five minutes. A value of -1
indicates that the utilization number is not available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.6.1.5 |
cpqHeSysUtilPciThirtyMinThe utilization as a percentage of the theoretical
maximum during the last thirty minutes. A value of -1
indicates that the utilization number is not available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.6.1.6 |
cpqHeSysUtilPciHourThe utilization as a percentage of the theoretical
maximum during the last hour. A value of -1 indicates
that the utilization number is not available.ro INTEGER .1.3.6.1.4.1.232.6.2.8.6.1.7 |
cpqHeSysUtilPciHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the PCI drawer.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.8.6.1.8 |
cpqHeFltTolPwrSupply OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.9 |
cpqHeFltTolPwrSupplyConditionThis value specifies the overall condition of the fault tolerant
power supply sub-system.ro Enumeration .1.3.6.1.4.1.232.6.2.9.1 |
cpqHeFltTolPwrSupplyStatusThis value specifies the status of the fault tolerant power
supply.ro Enumeration .1.3.6.1.4.1.232.6.2.9.2 |
cpqHeFltTolPowerSupplyTableA table of Power Supply Entries. SEQUENCE OF CpqHeFltTolPowerSupplyEntry .1.3.6.1.4.1.232.6.2.9.3 |
cpqHeFltTolPowerSupplyEntryA Fault Tolerant Power Supply Entry. CpqHeFltTolPowerSupplyEntry .1.3.6.1.4.1.232.6.2.9.3.1 |
cpqHeFltTolPowerSupplyChassisThe system chassis number.ro INTEGER .1.3.6.1.4.1.232.6.2.9.3.1.1 |
cpqHeFltTolPowerSupplyBayThe bay number to index within this chassis.ro INTEGER .1.3.6.1.4.1.232.6.2.9.3.1.2 |
cpqHeFltTolPowerSupplyPresentIndicates whether the power supply is present in the chassis.ro Enumeration .1.3.6.1.4.1.232.6.2.9.3.1.3 |
cpqHeFltTolPowerSupplyConditionThe condition of the power supply.
This value will be one of the following:
other(1)
The status could not be determined or not present.
ok(2)
The power supply is operating normally.
degraded(3)
A temperature sensor, fan or other power supply component is
outside of normal operating range.
failed(4)
A power supply component detects a condition that could
permanently damage the system.ro Enumeration .1.3.6.1.4.1.232.6.2.9.3.1.4 |
cpqHeFltTolPowerSupplyStatusThe status of the power supply.ro Enumeration .1.3.6.1.4.1.232.6.2.9.3.1.5 |
cpqHeFltTolPowerSupplyMainVoltageThe input main voltage of the power supply in volts.ro INTEGER .1.3.6.1.4.1.232.6.2.9.3.1.6 |
cpqHeFltTolPowerSupplyCapacityUsedThe currently used capacity of the power supply in watts.ro INTEGER .1.3.6.1.4.1.232.6.2.9.3.1.7 |
cpqHeFltTolPowerSupplyCapacityMaximumThe maximum capacity of the power supply in watts.ro INTEGER .1.3.6.1.4.1.232.6.2.9.3.1.8 |
cpqHeFltTolPowerSupplyRedundantThe redundancy state of the power supply.
This value will be one of the following:
other(1)
The redundancy state could not be determined.
notRedundant(2)
The power supply is not operating in a redundant state.
redundant(3)
The power supply is operating in a redundant state.ro Enumeration .1.3.6.1.4.1.232.6.2.9.3.1.9 |
cpqHeFltTolPowerSupplyModelThe power supply model name.ro DisplayString .1.3.6.1.4.1.232.6.2.9.3.1.10 |
cpqHeFltTolPowerSupplySerialNumberThe power supply serial number.ro DisplayString .1.3.6.1.4.1.232.6.2.9.3.1.11 |
cpqHeFltTolPowerSupplyAutoRevThe power supply auto revision number.ro OCTET STRING .1.3.6.1.4.1.232.6.2.9.3.1.12 |
cpqHeFltTolPowerSupplyHotPlugThis indicates if the power supply is capable of being
removed and/or inserted while the system is in an operational
state.
If the value is hotPluggable(3), the power supply can be safely
removed if and only if the cpqHeFltTolPowerSupplyRedundant
field is in a redundant(3) state.
This value will be one of the following:
other(1)
The state could not be determined.
nonHotPluggable(2)
The power supply is not hot plug capable.
hotPluggable(3)
The power supply is hot plug capable and can be removed if
the system is operating in a redundant state. A power
supply may be added to an empty power supply bay.ro Enumeration .1.3.6.1.4.1.232.6.2.9.3.1.13 |
cpqHeFltTolPowerSupplyFirmwareRevThe power supply firmware revision. This field will be left
blank if the firmware revision is unknown.ro DisplayString .1.3.6.1.4.1.232.6.2.9.3.1.14 |
cpqHeFltTolPowerSupplyHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the power supply.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.9.3.1.15 |
cpqHeFltTolPowerSupplySparePartNumThe power supply part number or spare part number.ro DisplayString .1.3.6.1.4.1.232.6.2.9.3.1.16 |
cpqHeFltTolPowerSupplyRedundantPartnerThis specifies the index of the redundant partner. A value
of zero will be used if there is no redundant partner.ro INTEGER .1.3.6.1.4.1.232.6.2.9.3.1.17 |
cpqHeFltTolPowerSupplyErrorConditionThe Error condition of the power supply.ro Enumeration .1.3.6.1.4.1.232.6.2.9.3.1.18 |
cpqHeIRC OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.10 |
cpqHeIRCStatusThe status of the Integrated Remote Console. A value of notavailable
will be returned if this system does not contain IRC.ro Enumeration .1.3.6.1.4.1.232.6.2.10.1 |
cpqHeEventLog OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.11 |
cpqHeEventLogSupportedThis value specifies if this system supports the Integrated
Management Log feature.
An SNMP set of the value clear(4) will clear the System Event
Log of all entries.rw Enumeration .1.3.6.1.4.1.232.6.2.11.1 |
cpqHeEventLogConditionThis value specifies the overall condition of the Integrated
Management Log feature.ro Enumeration .1.3.6.1.4.1.232.6.2.11.2 |
cpqHeEventLogTableA table of System Event Log Entries. SEQUENCE OF CpqHeEventLogEntry .1.3.6.1.4.1.232.6.2.11.3 |
cpqHeEventLogEntryA System Event Log Entry. CpqHeEventLogEntry .1.3.6.1.4.1.232.6.2.11.3.1 |
cpqHeEventLogEntryNumberA number that uniquely specifies this system event log
entry.ro INTEGER .1.3.6.1.4.1.232.6.2.11.3.1.1 |
cpqHeEventLogEntrySeverityThis value specifies the severity of the event log entry.
A caution or critical entry can have it's severity
lowered by setting this variable to the repaired state.rw Enumeration .1.3.6.1.4.1.232.6.2.11.3.1.2 |
cpqHeEventLogEntryClassThis value specifies the event log entry class designation.ro INTEGER .1.3.6.1.4.1.232.6.2.11.3.1.3 |
cpqHeEventLogEntryCodeThis value specifies the event log entry code designation.
The meaning of this changes depending on the class.ro INTEGER .1.3.6.1.4.1.232.6.2.11.3.1.4 |
cpqHeEventLogEntryCountThis value specifies the event log entry occurrence count.
This represents the number of times this event has occurred
starting from the initial time until the last modified time.ro INTEGER .1.3.6.1.4.1.232.6.2.11.3.1.5 |
cpqHeEventLogInitialTimeThe time stamp when the event log entry was first created.
field octets contents range
===== ====== ======== =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
The year field is set with the most significant octet first.
A value of 0 in the year indicates an unknown time stamp.ro OCTET STRING .1.3.6.1.4.1.232.6.2.11.3.1.6 |
cpqHeEventLogUpdateTimeThe time stamp when the event log entry was last modified.
field octets contents range
===== ====== ======== =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
The year field is set with the most significant octet first.
A value of 0 in the year indicates an unknown time stamp.ro OCTET STRING .1.3.6.1.4.1.232.6.2.11.3.1.7 |
cpqHeEventLogErrorDescA text description of the event log entry.ro DisplayString .1.3.6.1.4.1.232.6.2.11.3.1.8 |
cpqHeEventLogFreeFormDataThis is the free form data associated with a particular
event.ro OCTET STRING .1.3.6.1.4.1.232.6.2.11.3.1.9 |
cpqHeMgmtDisplay OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.12 |
cpqHeMgmtDisplayTypeThis value specifies the type of Management Display device.
If a display device is available on the server, the type
will be set accordingly. If no device is present, the value
will be set to none(2).ro Enumeration .1.3.6.1.4.1.232.6.2.12.1 |
cpqHeMgmtDisplayTextThe text to be written to the Management display device.
If this item is read, it may not accurately reflect what
is currently displayed.rw DisplayString .1.3.6.1.4.1.232.6.2.12.2 |
cpqHeMgmtUIDThe Unit Identifier LED.
This value will be one of the following:
other(1)
The state of the LED could not be determined. Setting the
LED state is not allowed.
none(2)
The LED is not present. Setting LED state is not allowed.
ledOn(3)
The LED is present and ON. The LED can be turned Off or Blinking
by setting the cpqHeMgmtUID to ledOff(4) or ledBlinking(5) respectively.
ledOff(4)
The LED is present and OFF. The LED can be turned On or Blinking
by setting the cpqHeMgmtUID to ledOn(3) or ledBlinking(5) respectively.
ledBlinking(5)
The LED is present and is Blinking. The LED can be turned On or Off
by setting the cpqHeMgmtUID to ledOn(3) or ledOff(4) respectivelyrw Enumeration .1.3.6.1.4.1.232.6.2.12.3 |
cpqHePowerConverter OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.13 |
cpqHePowerConverterSupportedThis value specifies if this system supports reporting
power converter module information.ro Enumeration .1.3.6.1.4.1.232.6.2.13.1 |
cpqHePowerConverterConditionThis value specifies the overall condition of the power
converters modules in the system.ro Enumeration .1.3.6.1.4.1.232.6.2.13.2 |
cpqHePowerConverterTableA table of Power Converter Module Entries. SEQUENCE OF CpqHePowerConverterEntry .1.3.6.1.4.1.232.6.2.13.3 |
cpqHePowerConverterEntryA Power Converter Module Entry. CpqHePowerConverterEntry .1.3.6.1.4.1.232.6.2.13.3.1 |
cpqHePwrConvChassisThe system chassis number containing the power converter
modules.ro INTEGER .1.3.6.1.4.1.232.6.2.13.3.1.1 |
cpqHePwrConvIndexThe Power Converter Module number to index within the chassis.ro INTEGER .1.3.6.1.4.1.232.6.2.13.3.1.2 |
cpqHePwrConvPresentThis specifies if the Power Converter Module described is
present in the system.ro Enumeration .1.3.6.1.4.1.232.6.2.13.3.1.3 |
cpqHePwrConvSlotThe Power Converter Module slot number within the chassis.ro INTEGER .1.3.6.1.4.1.232.6.2.13.3.1.4 |
cpqHePwrConvSocketThe Power Converter Module socket number within the slot.ro INTEGER .1.3.6.1.4.1.232.6.2.13.3.1.5 |
cpqHePwrConvRedundantThis specifies if the Power Converter Module is redundant.ro Enumeration .1.3.6.1.4.1.232.6.2.13.3.1.6 |
cpqHePwrConvRedundantGroupIdThe Power Converter Module group id. A redundant set of
power converters will have the same group id.ro INTEGER .1.3.6.1.4.1.232.6.2.13.3.1.7 |
cpqHePwrConvConditionThe Power Converter Module condition.ro Enumeration .1.3.6.1.4.1.232.6.2.13.3.1.8 |
cpqHePwrConvHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the power converter.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.13.3.1.9 |
cpqHeResilientMemory OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.14 |
cpqHeResilientMemTypeActiveThis value specifies the type of Advanced Memory Protection fault
tolerance currently active on the system.
The following connection states are supported:
other(1)
The Advanced Memory Protection fault tolerance cannot be
determined by the Management Agent. You may need to upgrade
your software.
none(2)
This system is not configured for Advanced Memory Protection
fault tolerance or Advanced Memory Protection is not available
on this system.
onLineSpare(3)
This system is configured for Online Spare Advanced Memory
Protection.
mirrored(4)
This system is configured for Mirrored Advanced Memory
Protection.
advancedECC(5)
This system is configured for the Advanced ECC type of
Advanced Memory Protection.
mirroredSingleBoard(6)
This system is configured for Mirrored Advanced Memory
Protection within a single memory board.
mirroredDualBoard(7)
This system is configured for Mirrored Advanced Memory
Protection within a dual memory board configuration. The
mirrored memory may be swapped with memory on the same
memory board or with memory on the second memory board.
xor(8)
This system is configured for Advanced Memory Protection
using the XOR engine.
lockStep(9)
This system is configured for LockStep type of
Advanced Memory Protection.
onLineSpareChannel(10)
This system is configured for Online Spare Channel Advanced
Memory Protection.
onLineSpareRank(11)
This system is configured for Online Spare Rank Advanced
Memory Protection.
mirroringIntrasocket(12)
This system is configured for Mirrored Intrasocket Advanced
Memory Protection between memory of single processor or board.
mirroringIntersocket(13)
This system is configured for Mirrored Intersocket Advanced
Memory Protection between memory of two processors or boards.ro Enumeration .1.3.6.1.4.1.232.6.2.14.1 |
cpqHeResilientMemTypeAvailableThis value specifies the type of Advanced Memory Protection
Fault Tolerance available on the system.
This is a collection of flags used to indicate the fault
Advanced Memory Protection options available. This integer
is a bitmap, with each bit indicating the availability of an
option. If the bit is set to 1, the option is available;
otherwise it is not. Multiple options are allowed.
NOTE: bit 31 is the most significant bit, bit 0 is the least
significant.
Bit 31-11: RESERVED (0)
Bit 10: Mirroring Intersocket
Bit 9: Mirroring Intrasocket
Bit 8: Online Rank Spare
Bit 7: Online Channel Spare
Bit 6: LockStep
Bit 5: XOR
Bit 4: Mirrored Memory with dual memory boards
Bit 3: Mirrored Memory within a single memory board
Bit 2: Advanced ECC
Bit 1: Mirrored (deprecated)
Bit 0: Online Sparero INTEGER .1.3.6.1.4.1.232.6.2.14.2 |
cpqHeResilientMemStatusThis value specifies the current state of the Advanced
Memory Protection subsystem.
The following states are supported:
other(1)
The system does not support Advanced Memory Protection or the
status cannot be determined by the Management Agent.
notProtected(2)
This system supports Advanced Memory Protection but the
feature is disabled.
protected(3)
The system is protected by Advanced Memory Protection.
degraded(4)
The system was protected, but the Advanced Memory
Protection feature has been engaged.
dimmEcc(5)
The system is protected via DIMM ECC only.
mirrorNoFaults(6)
The system is protected by Advanced Memory Protection in the
mirrored mode. No DIMM faults have been detected.
mirrorWithFaults(7)
The system is protected by Advanced Memory Protection in the
mirrored mode. One or more DIMM faults have been detected.
hotSpareNoFaults(8)
The system is protected by Advanced Memory Protection in the
hot spare mode. No DIMM faults have been detected.
hotSpareWithFaults(9)
The system is protected by Advanced Memory Protection in the
hot spare mode. One or more DIMM faults have been detected.
xorNoFaults(10)
The system is protected by Advanced Memory Protection in the
XOR memory mode. No DIMM faults have been detected.
xorWithFaults(11)
The system is protected by Advanced Memory Protection in the
XOR memory mode. One or more DIMM faults have been detected.
advancedEcc(12)
The system is protected by Advanced Memory Protection in the
Advanced ECC mode.
advancedEccWithFaults(13)
The system is protected by Advanced Memory Protection in the
Advanced ECC mode. One or more DIMM faults have been detected.
lockStep(14)
The system is protected by Advanced Memory Protection in the
Lock Step mode.
localStepWithFaults(15)
The system is protected by Advanced Memory Protection in the
Lock Step mode. One or more DIMM faults have been detected.ro Enumeration .1.3.6.1.4.1.232.6.2.14.3 |
cpqHeResilientMemConditionThis value specifies the current condition of the Advanced
Memory Protection subsystem.
The following states are supported:
other(1)
The system does not support fault tolerant memory or the
state cannot be determined by the Management Agent.
ok(2)
This system is operating normally.
degraded(3)
The system is running in a degraded state because the
Advanced Memory Protection subsystem has been engaged.ro Enumeration .1.3.6.1.4.1.232.6.2.14.4 |
cpqHeResilientMemHotPlugThis value specifies the current condition of the Advanced
Memory Protection subsystem.
The following states are supported:
other(1)
The state could not be determined or the system does not
support Advanced Memory Protection.
nonHotPluggable(2)
The memory board or cartridge is not hot plug capable.
hotPluggable(3)
The memory board or cartridge is hot plug capable and can be
removed if the system is operating in a redundant state. A
memory board or cartridge may be added to an empty bay.ro Enumeration .1.3.6.1.4.1.232.6.2.14.5 |
cpqHeResilientMemOperatingSpeedThis value specifies the current operating speed of the Advanced
Memory Protection subsystem in MHz.
If this system does not support Advanced Memory Protection or this
value cannot be determined, then a value of 0 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.14.6 |
cpqHeResilientMemOsMemSizeThis value specifies the size of memory as seen by the Operating
System in MB (1 MB = 1048576 bytes).
If this system does not support Advanced Memory Protection or this
value cannot be determined, then a value of 0 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.14.7 |
cpqHeResilientMemTotalMemSizeThis value specifies the total size of memory including memory seen
by the Operating System and the memory used for spare, mirrored, or
RAID configurations in MB (1 MB = 1048576 bytes).
If this system does not support Advanced Memory Protection or this
value cannot be determined, then a value of 0 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.14.8 |
cpqHeResilientMemRivStateThis value specifies the state of the Rebuild/Initialize/Verify
(RIV) engine of the Advanced Memory Protection sub-system.
The following states are supported:
other(1)
The system does not support Advanced Memory Protection or this
value cannot be determined,
inactive(2)
The RIV engine is idle.
rebuilding(3)
The RIV engine is rebuilding the XOR data.
initializing(4)
The RIV engine is initializing memory.
verifying(5)
The RIV engine is verifying memory integrity.ro Enumeration .1.3.6.1.4.1.232.6.2.14.9 |
cpqHeResMemBoardTableA table of memory board or cartridge descriptions in Advanced
Memory Protection systems. SEQUENCE OF CpqHeResMemBoardEntry .1.3.6.1.4.1.232.6.2.14.10 |
cpqHeResMemBoardEntryA memory board or cartridge description. CpqHeResMemBoardEntry .1.3.6.1.4.1.232.6.2.14.10.1 |
cpqHeResMemBoardSlotIndexThe slot in which the memory board or cartridge is installed.ro INTEGER .1.3.6.1.4.1.232.6.2.14.10.1.1 |
cpqHeResMemBoardOnlineStatusThe online status of the Advanced Memory Protection board or
cartridge.
The following status values are supported:
other(1)
The value is unsupported or could not be determined.
present(2)
The board or cartridge has memory and is currently online.
absent(3)
The board or cartridge is missing or offline.ro Enumeration .1.3.6.1.4.1.232.6.2.14.10.1.2 |
cpqHeResMemBoardErrorStatusThe error status of the Advanced Memory Protection board or
cartridge.
The following status values are supported:
other(1)
The value is unsupported or could not be determined.
noError(2)
The board or cartridge is configured and operating correctly.
dimmEccError(3)
The board or cartridge has at least one DIMM ECC error.
unlockError(4)
The board or cartridge is unlocked when it should not be.
Please insure the board of cartridge is locked.
configError(5)
The board or cartridge has a bad memory configuration.
Please insure all memory modules are of the correct type,
speed, latency, etc.
busError(6)
The board or cartridge has a memory bus error.
Please insure all memory modules are of the correct type,
speed, latency, etc. Also insure the cartridge is inserted
properly.
powerError(7)
The board or cartridge has power error.
Please insure all memory modules are of the correct type,
speed, latency, etc. Also insure the cartridge is inserted
properly.
advancedEcc(8),
The board or cartridge is configured for advanced Ecc mode.
onlineSpare(9),
The board or cartridge is configured for Online Spare mode.
mirrored(10),
The board or cartridge is configured for mirrored mode.
mirroredDimmError(11),
The board or cartridge has a mirrored Dimm error.
memoryRaid(12),
The board or cartridge is configured for memory raid mode.
raidDimmError(13)
The board or cartridge has a raid Dimm error.
lockstep(14)
The board or cartridge is configured for LockStep.
lockstepDimmError(15)
The board or cartridge has a lockStep Dimm error.ro Enumeration .1.3.6.1.4.1.232.6.2.14.10.1.3 |
cpqHeResMemBoardLockedThe locked state of the Advanced Memory Protection board or
cartridge.
The following status values are supported:
other(1)
The value is unsupported or could not be determined. If the
system does not support hot plugging of the board or
cartridge, then this value will be returned.
unlocked(2)
The board or cartridge is currently unlocked and may be
removed.
locked(3)
The board or cartridge is currently locked and may not be
removed.ro Enumeration .1.3.6.1.4.1.232.6.2.14.10.1.4 |
cpqHeResMemBoardNumSocketsThe total number of memory sockets for this memory board or
cartridge.
If this value could not be determined, or if the board or
cartridge has been removed, this value will be -1.ro INTEGER .1.3.6.1.4.1.232.6.2.14.10.1.5 |
cpqHeResMemBoardOsMemSizeThis value specifies the size of memory for this board or
cartridge as seen by the Operating System in MB (1 MB =
1048576 bytes).
If this system does not support Advanced Memory Protection or this
value cannot be determined, then a value of 0 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.14.10.1.6 |
cpqHeResMemBoardTotalMemSizeThis value specifies the size of memory for this board or
cartridge including memory seen by the Operating System and
the memory used for spare, mirrored, or XOR configurations
in MB (1 MB = 1048576 bytes).
If this system does not support Advanced Memory Protection or this
value cannot be determined, then a value of 0 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.14.10.1.7 |
cpqHeResMemBoardConditionThis provides the current status of the Advanced Memory
Protection memory board or cartridge.
The following status values are supported:
other(1):
The condition of this memory board or cartridge
could not be determined.
ok(2):
The memory board or cartridge is operating normally.
degraded(3):
The memory board or cartridge is in an error state.
Check for correct memory installation and that the
board has been inserted properly.ro Enumeration .1.3.6.1.4.1.232.6.2.14.10.1.8 |
cpqHeResMemBoardHotPlugThis indicates if the memory board is capable of being
removed and/or inserted while the system is in an
operational state.
The following states are supported:
other(1)
The state could not be determined or the system does not
support Advanced Memory Protection.
nonHotPluggable(2)
The memory board or cartridge is not hot plug capable.
hotPluggable(3)
The memory board or cartridge is hot plug capable and can be
removed if the system is operating in a redundant state. A
memory board or cartridge may be added to an empty bay.ro Enumeration .1.3.6.1.4.1.232.6.2.14.10.1.9 |
cpqHeResMemModuleTableA table of memory module descriptions. SEQUENCE OF CpqHeResMemModuleEntry .1.3.6.1.4.1.232.6.2.14.11 |
cpqHeResMemModuleEntryA memory module description. CpqHeResMemModuleEntry .1.3.6.1.4.1.232.6.2.14.11.1 |
cpqHeResMemBoardIndexThe slot in which the memory board or cartridge is installed.
A value of 0 indicates memory installed directly on the
system board.ro INTEGER .1.3.6.1.4.1.232.6.2.14.11.1.1 |
cpqHeResMemModuleIndexThe memory module number.ro INTEGER .1.3.6.1.4.1.232.6.2.14.11.1.2 |
cpqHeResMemModuleSparePartNoThe memory module's manufacturer part number.
This field will be a null (size 0) string if the manufacturer
part number is not available.ro DisplayString .1.3.6.1.4.1.232.6.2.14.11.1.3 |
cpqHeResMemModuleStatusThis provides the current status of the correctable memory
errors for this memory module.
The following status values are supported:
other(1):
The status is unknown or could not be determined.
notPresent(2):
The memory module is not present or is un-initialized.
present(3):
The memory module is present but not in use.
good(4):
The memory module is present and in use. The corrected
error threshold has not been exceeded.
add(5):
The memory module has been added, but is not yet in use.
upgraded(6):
The memory module has been upgraded, but the memory is not
yet in use.
missing(7):
An expected memory module is missing.
doesNotMatch(8):
The memory module does not match the other memory modules
within the bank.
notSupported(9):
The memory module is not supported.
badConfig(10):
The memory module violates the add/upgrade configuration
rules.
degraded(11):
The memory module's correctable error count has exceeded
threshold.ro Enumeration .1.3.6.1.4.1.232.6.2.14.11.1.4 |
cpqHeResMemModuleConditionThis provides the current status of the correctable memory
errors for this memory module.
The following status values are supported:
other(1):
ECC is not supported on this memory module or the
condition could not be determined.
ok(2):
The memory module is operating normally.
degraded(3):
The memory module is correctable error count has exceeded
threshold or a configuration error has been detected.ro Enumeration .1.3.6.1.4.1.232.6.2.14.11.1.5 |
cpqHeResMemModuleSpdThis is the raw Serial Presence Detect information contained
in the memory module.
If the SPD information is not available, this item will be empty.ro OCTET STRING .1.3.6.1.4.1.232.6.2.14.11.1.6 |
cpqHeResMem2BoardTableA table of memory board or cartridge descriptions in Advanced
Memory Protection systems. SEQUENCE OF CpqHeResMem2BoardEntry .1.3.6.1.4.1.232.6.2.14.12 |
cpqHeResMem2BoardEntryA memory board or cartridge or CPU based Memory Board description. CpqHeResMem2BoardEntry .1.3.6.1.4.1.232.6.2.14.12.1 |
cpqHeResMem2BoardIndexThis will represent the unique memory board or cartridge or riser.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.1 |
cpqHeResMem2BoardSlotNumThe slot in which the memory board or cartridge is installed.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.2 |
cpqHeResMem2BoardCpuNumThe Processor Number to which the memory Riser belongs. Value 0 means memory is not CPU based.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.3 |
cpqHeResMem2BoardRiserNumThe Riser Number on the Processor.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.4 |
cpqHeResMem2BoardOnlineStatusThe online status of the Advanced Memory Protection board or
cartridge or riser.
The following status values are supported:
other(1)
The value is unsupported or could not be determined.
present(2)
The board or cartridge or riser has memory and is currently online.
absent(3)
The board or cartridge or riser is missing or offline.ro Enumeration .1.3.6.1.4.1.232.6.2.14.12.1.5 |
cpqHeResMem2BoardErrorStatusThe error status of the Advanced Memory Protection board or
Cartridge or riser.
The following status values are supported:
other(1)
The value is unsupported or could not be determined.
noError(2)
The board or cartridge or riser is configured and operating correctly.
dimmEccError(3)
The board or cartridge or riser has at least one DIMM ECC error.
unlockError(4)
The board or cartridge or riser is unlocked when it should not be.
Please insure the board of cartridge is locked.
configError(5)
The board or cartridge or riser has a bad memory configuration.
Please insure all memory modules are of the correct type,
speed, latency, etc.
busError(6)
The board or cartridge or riser has a memory bus error.
Please insure all memory modules are of the correct type,
speed, latency, etc. Also insure the cartridge is inserted
properly.
powerError(7)
The board or cartridge or riser has power error.
Please insure all memory modules are of the correct type,
speed, latency, etc. Also insure the cartridge is inserted
properly.
advancedEcc(8),
The board or cartridge or riser is configured for advanced Ecc mode.
onlineSpare(9),
The board or cartridge or riser is configured for Online Spare mode.
mirrored(10),
The board or cartridge or riser is configured for mirrored mode.
mirroredDimmError(11),
The board or cartridge or riser has a mirrored Dimm error.
memoryRaid(12),
The board or cartridge or riser is configured for memory raid mode.
raidDimmError(13)
The board or cartridge or riser has a raid Dimm error.
lockStep(14),
The board or cartridge or riser is configured for lockStep mode.
lockStepError(15)
The board or cartridge or riser has a lockStep Dimm error.ro Enumeration .1.3.6.1.4.1.232.6.2.14.12.1.6 |
cpqHeResMem2BoardLockedThe locked state of the Advanced Memory Protection board or
Cartridge or riser.
The following status values are supported:
other(1)
The value is unsupported or could not be determined. If the
system does not support hot plugging of the board or
cartridge or riser, then this value will be returned.
unlocked(2)
The board or cartridge or riser is currently unlocked and may be
removed.
locked(3)
The board or cartridge or riser is currently locked and may not be
removed.ro Enumeration .1.3.6.1.4.1.232.6.2.14.12.1.7 |
cpqHeResMem2BoardNumSocketsThe total number of memory sockets for this memory board or
Cartridge or riser.
If this value could not be determined, or if the board or
Cartridge or riser has been removed, this value will be -1.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.8 |
cpqHeResMem2BoardOsMemSizeThis value specifies the size of memory for this board or
cartridge or riser as seen by the Operating System in MB (1 MB =
1048576 bytes).
If this system does not support Advanced Memory Protection or this
value cannot be determined, then a value of 0 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.9 |
cpqHeResMem2BoardTotalMemSizeThis value specifies the size of memory for this board or
Cartridge or riser including memory seen by the Operating System and
the memory used for spare, mirrored, or XOR configurations
in MB (1 MB = 1048576 bytes).
If this system does not support Advanced Memory Protection or this
value cannot be determined, then a value of 0 will be returned.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.10 |
cpqHeResMem2BoardConditionThis provides the current status of the Advanced Memory
Protection memory board or cartridge or riser.
The following status values are supported:
other(1):
The condition of this memory board or cartridge or riser
could not be determined.
ok(2):
The memory board or cartridge or riser is operating normally.
degraded(3):
The memory board or cartridge or riser is in an error state.
Check for correct memory installation and that the
board has been inserted properly.ro Enumeration .1.3.6.1.4.1.232.6.2.14.12.1.11 |
cpqHeResMem2BoardHotPlugThis indicates if the memory board is capable of being
removed and/or inserted while the system is in an
operational state.
The following states are supported:
other(1)
The state could not be determined or the system does not
support Advanced Memory Protection.
nonHotPluggable(2)
The memory board or cartridge or riser is not hot plug capable.
hotPluggable(3)
The memory board or cartridge or riser is hot plug capable and can be
removed if the system is operating in a redundant state. A
memory board or cartridge or riser may be added to an empty bay.ro Enumeration .1.3.6.1.4.1.232.6.2.14.12.1.12 |
cpqHeResMem2BoardOperatingFrequencyThis value specifies the operational memory frequency for
this board or Cartridge or riser in MHz.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.13 |
cpqHeResMem2BoardOperatingVoltageThis value specifies the operational memory voltage for
this board or Cartridge or riser in millivolts.ro INTEGER .1.3.6.1.4.1.232.6.2.14.12.1.14 |
cpqHeResMem2ModuleTableA table of memory module descriptions. SEQUENCE OF CpqHeResMem2ModuleEntry .1.3.6.1.4.1.232.6.2.14.13 |
cpqHeResMem2ModuleEntryA memory module description. CpqHeResMem2ModuleEntry .1.3.6.1.4.1.232.6.2.14.13.1 |
cpqHeResMem2ModuleThis will represent the unique memory DIMM on
memory board or cartridge or riser.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.1 |
cpqHeResMem2BoardNumThe slot in which the memory board or cartridge is installed.
A value of 0 indicates memory installed directly on the
system board.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.2 |
cpqHeResMem2CpuNumThe memory module CPU number. Value 0 means memory is not Processor based.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.3 |
cpqHeResMem2RiserNumThe memory module rasier number.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.4 |
cpqHeResMem2ModuleNumThe memory module number.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.5 |
cpqHeResMem2ModuleSizeModule memory size in kilobytes. A kilobyte of memory is
defined as 1024 bytes.
A size of 0 indicates the module is not present.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.6 |
cpqHeResMem2ModuleTypeType of memory module installed. The value other(1) will be
given if the type is not known. The value board(2) will be
given if the memory module is permanently mounted (not modular)
on a system board or memory expansion board.ro Enumeration .1.3.6.1.4.1.232.6.2.14.13.1.7 |
cpqHeResMem2ModuleTechnologyTechnology type of memory module installed. The value other(1)
will be given if the technology is not known.ro Enumeration .1.3.6.1.4.1.232.6.2.14.13.1.8 |
cpqHeResMem2ModuleManufacturerThe memory module's manufacturer name.
This field will be a null (size 0) string if the manufacturer
name is not available.ro DisplayString .1.3.6.1.4.1.232.6.2.14.13.1.9 |
cpqHeResMem2ModulePartNoThe memory module's manufacturer part number.
This field will be a null (size 0) string if the manufacturer
part number is not available.ro DisplayString .1.3.6.1.4.1.232.6.2.14.13.1.10 |
cpqHeResMem2ModuleDateThe memory module date of manufacture.
field octets contents range
===== ====== ====================== ========
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the date of manufacture
is not available. The hour, minute, and second fields will
always be set to 0.ro OCTET STRING .1.3.6.1.4.1.232.6.2.14.13.1.11 |
cpqHeResMem2ModuleSerialNoThe memory module's serial number.
This field will be a null (size 0) string if the serial number
is not available.rw DisplayString .1.3.6.1.4.1.232.6.2.14.13.1.12 |
cpqHeResMem2ModuleHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the memory module.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.6.2.14.13.1.13 |
cpqHeResMem2ModuleFrequencyThe memory module maximum frequency in MHz. The value zero
(0) will be given if the module frequency cannot be determined.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.14 |
cpqHeResMem2ModuleCellTablePtrIndex for the cell in cpqSeCellTable where the memory board is
installed.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.15 |
cpqHeResMem2ModuleCellStatusThis provides the current status for this memory module.
The following status values are supported:
other(1):
The memory module status is not available
ok(2):
The memory module is active
deconfigured(3):
The memory module is not readyro Enumeration .1.3.6.1.4.1.232.6.2.14.13.1.16 |
cpqHeResMem2ModulePartNoMfgrThe memory module's manufacturer's part number.
This field will be a null (size 0) string if the manufacturer
part number is not available.ro DisplayString .1.3.6.1.4.1.232.6.2.14.13.1.17 |
cpqHeResMem2ModuleSerialNoMfgrThe memory module's manufacturer's serial number.
This field will be a null (size 0) string if the manufacturer
serial number is not available.ro DisplayString .1.3.6.1.4.1.232.6.2.14.13.1.18 |
cpqHeResMem2ModuleStatusThis provides the current status of the correctable memory
errors for this memory module.
The following status values are supported:
other(1):
The status is unknown or could not be determined.
notPresent(2):
The memory module is not present or is un-initialized.
present(3):
The memory module is present but not in use.
good(4):
The memory module is present and in use. The corrected
error threshold has not been exceeded.
add(5):
The memory module has been added, but is not yet in use.
upgraded(6):
The memory module has been upgraded, but the memory is not
yet in use.
missing(7):
An expected memory module is missing.
doesNotMatch(8):
The memory module does not match the other memory modules
within the bank.
notSupported(9):
The memory module is not supported.
badConfig(10):
The memory module violates the add/upgrade configuration
rules.
degraded(11):
The memory module's correctable error count has exceeded
threshold.
spare(12):
The memory module is configured as a spare.
partial(13):
The memory module is present and is partially in use.ro Enumeration .1.3.6.1.4.1.232.6.2.14.13.1.19 |
cpqHeResMem2ModuleConditionThis provides the current status of the correctable memory
errors for this memory module.
The following status values are supported:
other(1):
ECC is not supported on this memory module or the
condition could not be determined.
ok(2):
The memory module is operating normally.
degraded(3):
The memory module is correctable error count has exceeded
threshold or a configuration error has been detected.
degradedModuleIndexUnknown(4):
The correctable error count has exceeded threshold.
The module number not available.ro Enumeration .1.3.6.1.4.1.232.6.2.14.13.1.20 |
cpqHeResMem2ModuleSpdThis is the raw Serial Presence Detect information contained
in the memory module.
If the SPD information is not available, this item will be empty.ro OCTET STRING .1.3.6.1.4.1.232.6.2.14.13.1.21 |
cpqHeResMem2ModuleSmartMemoryThis indicates whether the DIMM slot is populated with an HP
Smart Memory DIMM.
The following values are supported:
other(1):
HP SmartMemory not supported in this device.
notHPSmartMemory(2):
HP SmartMemory is NOT installed in DIMM slot (includes
the case where the DIMM slot is not populated).
isHPSmartMemory(3):
HP SmartMemory is installed in DIMM slot.ro Enumeration .1.3.6.1.4.1.232.6.2.14.13.1.22 |
cpqHeResMem2ModuleMinVoltageThis provides the minimum voltage needed for the module to
operate, in millivolts.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.23 |
cpqHeResMem2ModuleRanksThis provides the number of physical ranks on the module.ro INTEGER .1.3.6.1.4.1.232.6.2.14.13.1.24 |
cpqHePowerMeter OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.2.15 |
cpqHePowerMeterSupportThis value specifies whether Power Meter is supported
by this Server .
The following values are supported:
other(1)
Could not read the Power Meter status.
supported(2)
This system support Power Meter.
unsupported(3)
This system does not support Power Meter.ro Enumeration .1.3.6.1.4.1.232.6.2.15.1 |
cpqHePowerMeterStatusThis value specifies whether Power Meter reading is supported
by this Server .
The following values are supported:
other(1)
Could not read the Power Meter status.
present(2)
The Power Meter data is available.
absent(3)
The Power Meter data is not available at this time.ro Enumeration .1.3.6.1.4.1.232.6.2.15.2 |
cpqHePowerMeterCurrReadingThis is the current Power Meter reading in Watts.
This value shows the most recent power reading if available.
On systems without Power Meter support, this value will be -1.ro INTEGER .1.3.6.1.4.1.232.6.2.15.3 |
cpqHePowerMeterPrevReadingThis is the previous Power Meter reading in Watts.
This value shows previous power reading if available.
On systems without Power Meter support, this value will be -1.ro INTEGER .1.3.6.1.4.1.232.6.2.15.4 |
cpqHeTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.6.3 |
cpqHeTrapPktsThe total number of SNMP trap packets issued by the
Server Health agent.rodeprecated Counter .1.3.6.1.4.1.232.6.3.1 |
cpqHeTrapLogMaxSizeThe maximum number of entries that will currently be kept in
the trap log. If the maximum size has been reached and a new
trap occurs the oldest trap will be removed.rodeprecated INTEGER .1.3.6.1.4.1.232.6.3.2 |
cpqHeTrapLogTableAn ordered list of trap log entries (conceptually a queue). The
trap log entries will be kept in the order in which they were
generated with the most recent trap at index 1 and the oldest
trap entry at index trapLogMaxSize. If the maximum number of
entries has been reached and a new trap occurs the oldest trap
will be removed when the new trap is added so the trapMaxLogSize
is not exceeded.deprecated SEQUENCE OF CpqHeTrapLogEntry .1.3.6.1.4.1.232.6.3.3 |
cpqHeTrapLogEntryA description of a trap event.deprecated CpqHeTrapLogEntry .1.3.6.1.4.1.232.6.3.3.1 |
cpqHeTrapLogIndexThe value of this object uniquely identifies this trapLogEntry
at this time. The most recent trap will have an index of 1 and
the oldest trap will have an index of trapLogMaxSize. Because of
the queue-like nature of the trapLog this particular trap event's
index will change as new traps are issued.rodeprecated INTEGER .1.3.6.1.4.1.232.6.3.3.1.1 |
cpqHeTrapTypeThe type of the trap event this entry describes. This
number refers to an entry in a list of traps enumerating the
possible traps the Server Health agent may issue.rodeprecated Enumeration .1.3.6.1.4.1.232.6.3.3.1.2 |
cpqHeTrapTimeThe time of the trap event that this entry describes. The time
is given in year (first octet), month, day of month, hour,
minute, second (last octet) order. The octets are in Binary
Coded Decimal (BCD).rodeprecated OCTET STRING .1.3.6.1.4.1.232.6.3.3.1.3 |