CPQSINFO-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for CPQSINFO-MIB.
252
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
252 total| Object Name |
|---|
cpqSiHoodRemovedSystem hood is removed.
The hood status has been set to removed. The
system's hood is not in a properly installed state. This
situation may result in improper cooling of the system due
to air flow changes caused by the missing hood.
User Action: Replace the cover (hood), ensure the system's cover
is properly installed. Verify the system is in working order. TRAP-TYPE .1.3.6.1.4.1.232.0.2001 |
cpqSiMonitorConditionOKFault reporting features have returned to within their normal
operating range for the monitor indicated by cpqSiMonitorIndex.
The monitor's condition has been set to OK.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.2002 |
cpqSiMonitorConditionDegradedA fault reporting feature has exceeded normal limits for
the monitor indicated by the cpqSiMonitorIndex. The monitor's
condition is degraded due to the internal temperature exceeding
normal operating limits. The monitor is still useable, but
action should be taken to return the condition to OK.
User Action: Physically check for obstructions to air flow around
the monitor. Check the thermostat in the room that the system
occupies. Allow the monitor to cool by turning off the monitor
for 5 minutes then turn the monitor back on. After the monitor
cools, another alarm indicating an improving condition, such as
Monitor OK, will be issued. TRAP-TYPE .1.3.6.1.4.1.232.0.2003 |
cpqSiMonitorConditionFailedA fault reporting feature has exceeded normal limits in the
monitor indicated by the cpqSiMonitorIndex. The monitor's
condition has been set to failed due to an operational feature
exceeding normal operating limits. The monitor will not be
useable and should be replaced.
User Action: Make a note of the monitor model number and serial
number. Replace the monitor.
Refer to the appropriate Maintenance and Service Guide for
detailed information on a component replacement. TRAP-TYPE .1.3.6.1.4.1.232.0.2004 |
cpqSiCorrMemErrStatusDegradedCorrectable memory error count has exceeded the threshold for the
memory module indicated by the 'cpqSiMemErrorIndex' variable.
The appropriate cpqSiMemModuleECCStatus has been set to degraded.
User Action: For Desktops, the System Administrator should run
the F10 Diagnostics on this system and select RAM LONG TEST. If
it is determined that a module needs replacing, schedule
maintenance for the system and replace the failed memory module.
Refer to the appropriate Maintenance and Service Guide for detailed
information on a component replacement. TRAP-TYPE .1.3.6.1.4.1.232.0.2005 |
cpqSiCorrMemErrStatusOkCorrectable memory error count is now below the threshold for the
memory module indicated by the 'cpqSiMemErrorIndex' variable. The
appropriate cpqSiMemModuleECCStatus has been set to ok.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.2006 |
cpqSiMemConfigChangeA memory configuration change has occurred. CpqSiMemConfigChangeData
will indicate which memory modules slots have changed.
User Action: You may want to verify a valid reason for a memory
configuration to have occurred. If system issuing the alert is
a Desktop running NT, the memory configuration change information
is also logged in the NT System Log. TRAP-TYPE .1.3.6.1.4.1.232.0.2007 |
cpqSiHotPlugSlotBoardRemovedHot Plug Slot Board Removed.
A Hot Plug Slot Board has been removed from the specified
chassis and slot.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.2008 |
cpqSiHotPlugSlotBoardInsertedHot Plug Slot Board Inserted.
A Hot Plug Slot Board has been inserted into the specified
chassis and slot.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.2009 |
cpqSiHotPlugSlotPowerUpFailedHot Plug Slot Board Failed Power-Up.
A Hot Plug Slot Board has failed to power-up in the specified
chassis and slot.
User Action: Insure the board and all cables are installed
correctly and the board type and revision are the same as
the replaced board. TRAP-TYPE .1.3.6.1.4.1.232.0.2010 |
cpqSiSysBatteryFailureThe battery indicated by cpqSiSysBatteryIndex has failed
and must be replaced.
User Action: Contact your System Administrator or
Authorized Reseller to order a replacement battery.
Recycle your old battery. For proper disposal information,
refer to the documentation that came with your computer. TRAP-TYPE .1.3.6.1.4.1.232.0.2011 |
cpqSiSysBatteryChargingDegradedSignificant battery degradation has occurred with battery
indicated by cpqSiSysBatteryIndex. The battery can
no longer be fully recharged.
User Action: If using multiple batteries, run
the Power Conservation Utility to identify the
battery location. Contact your System Administrator
or Authorized Reseller to order a replacement
battery. TRAP-TYPE .1.3.6.1.4.1.232.0.2012 |
cpqSiSysBatteryCalibrationErrorCalibration is needed with battery
indicated by cpqSiSysBatteryIndex. The battery can
not correctly indicate capacity.
User Action: Run the Power Conservation Utility. Contact
your System Administrator or Authorized Reseller to
order a replacement battery. TRAP-TYPE .1.3.6.1.4.1.232.0.2013 |
cpqSystemInfo OBJECT IDENTIFIER .1.3.6.1.4.1.232.2 |
RFC1213-MIB Unknown .1.3.6.1.4.1.232.2 |
cpqSiMibRev OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.1 |
cpqSiMibRevMajorThe major revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level.ro INTEGER .1.3.6.1.4.1.232.2.1.1 |
cpqSiMibRevMinorThe minor revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred.ro INTEGER .1.3.6.1.4.1.232.2.1.2 |
cpqSiMibConditionThe overall condition.
This object represents the overall status of the server
information represented by this MIB.ro Enumeration .1.3.6.1.4.1.232.2.1.3 |
cpqSiComponent OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2 |
cpqSiInterface OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.1 |
cpqSiOsCommon OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.1.4 |
cpqSiOsCommonPollFreqThe Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero (0) will
always fail, an agent may also choose to fail any request to
change the poll frequency to a value that would severely impact
system performance.rw INTEGER .1.3.6.1.4.1.232.2.2.1.4.1 |
cpqSiOsCommonModuleTableA table of software modules that provide an interface to the
device this MIB describes.deprecated SEQUENCE OF CpqSiOsCommonModuleEntry .1.3.6.1.4.1.232.2.2.1.4.2 |
cpqSiOsCommonModuleEntryA description of a software module that provides an interface
to the device this MIB describes.deprecated CpqSiOsCommonModuleEntry .1.3.6.1.4.1.232.2.2.1.4.2.1 |
cpqSiOsCommonModuleIndexA unique index for this module description.rodeprecated INTEGER .1.3.6.1.4.1.232.2.2.1.4.2.1.1 |
cpqSiOsCommonModuleNameThe module name.rodeprecated DisplayString .1.3.6.1.4.1.232.2.2.1.4.2.1.2 |
cpqSiOsCommonModuleVersionThe module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be a null (size 0) string if the agent
cannot provide the module version.rodeprecated DisplayString .1.3.6.1.4.1.232.2.2.1.4.2.1.3 |
cpqSiOsCommonModuleDateThe module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first.rodeprecated OCTET STRING .1.3.6.1.4.1.232.2.2.1.4.2.1.4 |
cpqSiOsCommonModulePurposeThe purpose of the module described in this entry.rodeprecated DisplayString .1.3.6.1.4.1.232.2.2.1.4.2.1.5 |
cpqSiAsset OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.2 |
cpqSiSysSerialNumThe serial number of the physical system unit.
The string will be empty if the system does not report the
serial number function.ro DisplayString .1.3.6.1.4.1.232.2.2.2.1 |
cpqSiFormFactorThe form factor of the system. Setting this variable to
unknown will fail.rw Enumeration .1.3.6.1.4.1.232.2.2.2.2 |
cpqSiAssetTagThe customer changeable identifier that is set to the system
serial number at the time of manufacture.
The string will be empty if the system does not report this
function.rw DisplayString .1.3.6.1.4.1.232.2.2.2.3 |
cpqSiOwnershipTagThis is a customer changeable identifier that will be
displayed by ROM at POST. This is an 80 byte standard
ASCII character string and is Administrator Password
protected.
An example could be:
Property of Hewlett-Packard Company
The string should be NULL terminated. This item will be
empty if the system does not report this function.ro DisplayString .1.3.6.1.4.1.232.2.2.2.4 |
cpqSiSysServiceNumThe service number of the system unit.
The string will be empty if the system does not report the
system service number.ro DisplayString .1.3.6.1.4.1.232.2.2.2.5 |
cpqSiSysProductIdThe product id string of the system unit.
The string will be empty if the system does not report the
product id.ro DisplayString .1.3.6.1.4.1.232.2.2.2.6 |
cpqSiAssetTagMaxLengthMaximum allowed size in bytes of the asset tag.ro INTEGER .1.3.6.1.4.1.232.2.2.2.7 |
cpqSiVirtualSystemTableA table of virtual system information entries. SEQUENCE OF CpqSiVirtualSystemEntry .1.3.6.1.4.1.232.2.2.2.8 |
cpqSiVirtualSystemEntryA virtual system information table entry. CpqSiVirtualSystemEntry .1.3.6.1.4.1.232.2.2.2.8.1 |
cpqSiVirtualSystemIndexThe unique index of the virtual system information entry.ro INTEGER .1.3.6.1.4.1.232.2.2.2.8.1.1 |
cpqSiVirtualSystemSerialNumberThe HP Virtual Serial Number for the computer system package. The Virtual
Serial Number is the system serial number exposed to the operating
system when running in an HP Virtual Connect environment. The Virtual
Serial Number presented here will correspond to the Virtual UUID at the
same index location.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.2.8.1.2 |
cpqSiVirtualSystemUUIDThe HP Virtual UUID for the computer system package. The Virtual
UUID is the UUID number exposed to the operating system when running
in an HP Virtual Connect environment. The Virtual UUID presented
here will correspond to the Virtual serial number at the same index
location.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.2.8.1.3 |
cpqSiSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.3 |
cpqSiPowerOnPasswordThe state of the power on password feature.ro Enumeration .1.3.6.1.4.1.232.2.2.3.1 |
cpqSiNetServerModeThe state of the network server mode feature.ro Enumeration .1.3.6.1.4.1.232.2.2.3.2 |
cpqSiQuickLockPasswordThe state of the quicklock password feature.ro Enumeration .1.3.6.1.4.1.232.2.2.3.3 |
cpqSiQuickBlankThe state of the quick blank screen feature.ro Enumeration .1.3.6.1.4.1.232.2.2.3.4 |
cpqSiDisketteBootControlThe state of the diskette boot control feature.ro Enumeration .1.3.6.1.4.1.232.2.2.3.5 |
cpqSiSerialPortAControlThe state of the access control for the primary serial port
interface embedded in the system board.ro Enumeration .1.3.6.1.4.1.232.2.2.3.6 |
cpqSiSerialPortBControlThe state of the access control for the secondary serial port
interface embedded in the system board.ro Enumeration .1.3.6.1.4.1.232.2.2.3.7 |
cpqSiParallelPortControlThe state of the access control for the parallel port interface
embedded in the system board.ro Enumeration .1.3.6.1.4.1.232.2.2.3.8 |
cpqSiFloppyDiskControlThe state of the access control for the floppy diskette
interface embedded in the system board.ro Enumeration .1.3.6.1.4.1.232.2.2.3.9 |
cpqSiFixedDiskControlThe state of the access control for the fixed disk interface
embedded in the system board.ro Enumeration .1.3.6.1.4.1.232.2.2.3.10 |
cpqSiHoodRemovedTimeLast detection of hood removed by Smart Hood Sensor.ro DisplayString .1.3.6.1.4.1.232.2.2.3.11 |
cpqSiHoodSensorConfigurationThis is the current configuration of the Smart Cover
sensor.
The following values are currently defined:
other(1)
Smart Cover sensor is not supported on this system or cannot
be determined by the Insight Agent. You may need to upgrade
your software.
disabled(2)
Smart Cover sensor will not detect a hood removal and
cpqSiHoodRemovedTime will not be updated.
notifyUser(3)
Smart Cover sensor will detect a hood removal and will display
a message at POST for the user.
adminPasswordProtected(4)
Smart Cover sensor will detect a hood removal and will display
a message at POST for the user to enter the Admin Password.
The system will not boot until proper password is entered.ro Enumeration .1.3.6.1.4.1.232.2.2.3.12 |
cpqSiSmartCoverLockStatusThis is the current status of the Smart Cover
Lock. The following values are currently defined:
other(1)
Smart Cover Lock is not supported on this system or cannot
be determined by the Insight Agent. You may need to upgrade
your software.
unlocked(2)
Smart Cover Lock is not locked. The status will be set to
unlocked due to one of the following:
1. The system hood is removed, or
2. There is no administrator password set, or
3. The administrator manually sets status to unlock.
locked(3)
Smart Cover Lock is locked. The administrator password is
required to unlock the hood.ro Enumeration .1.3.6.1.4.1.232.2.2.3.13 |
cpqSiUSBPortControlThe state of the access control for the Universal
Serial Bus interface(s) embedded in the system
board.
other(1)
If Status could not be determined.
disabled(2)
USB interface is disable.
enabled(3)
USB interface is enable.
legacydisabled(4)
Legacy USB interface is disabled.
externalportdisabled(5)
External USB Ports are disabled.ro Enumeration .1.3.6.1.4.1.232.2.2.3.14 |
cpqSiSystemBoard OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.4 |
cpqSiProductIdThe machine product ID.
This value indicates the product type of the system board
in this system. The value 127 will be given if the machine ID
cannot be determined. A value of 127 will also be used for the
special case of a machine containing neither EISA nor ISA slots.ro INTEGER .1.3.6.1.4.1.232.2.2.4.1 |
cpqSiProductNameThe machine product name.
The name of the machine used in this system.ro DisplayString .1.3.6.1.4.1.232.2.2.4.2 |
cpqSiAuxiliaryInputThe state of the auxiliary input (pointing) device.ro Enumeration .1.3.6.1.4.1.232.2.2.4.4 |
cpqSiMemModuleTableA table of memory module descriptions. SEQUENCE OF CpqSiMemModuleEntry .1.3.6.1.4.1.232.2.2.4.5 |
cpqSiMemModuleEntryA memory module description. CpqSiMemModuleEntry .1.3.6.1.4.1.232.2.2.4.5.1 |
cpqSiMemBoardIndexThe slot in which the memory board or cartridge is installed.
A value of 0 indicates memory installed directly on the
system board.ro INTEGER .1.3.6.1.4.1.232.2.2.4.5.1.1 |
cpqSiMemModuleIndexThe memory module number.ro INTEGER .1.3.6.1.4.1.232.2.2.4.5.1.2 |
cpqSiMemModuleSizeModule memory size in kilobytes. A kilobyte of memory is
defined as 1024 bytes.
A size of 0 indicates the module is not present.ro INTEGER .1.3.6.1.4.1.232.2.2.4.5.1.3 |
cpqSiMemModuleTypeType of memory module installed. The value other(1) will be
given if the type is not known. The value board(2) will be
given if the memory module is permanently mounted (not modular)
on a system board or memory expansion board.ro Enumeration .1.3.6.1.4.1.232.2.2.4.5.1.4 |
cpqSiMemModuleSpeedModule memory speed in nanoseconds. The value zero (0) will
be given if the module speed cannot be determined.rodeprecated INTEGER .1.3.6.1.4.1.232.2.2.4.5.1.5 |
cpqSiMemModuleTechnologyTechnology type of memory module installed. The value other(1)
will be given if the technology is not known.ro Enumeration .1.3.6.1.4.1.232.2.2.4.5.1.6 |
cpqSiMemModuleManufacturerThe memory module's manufacturer name.
This field will be a null (size 0) string if the manufacturer
name is not available.ro DisplayString .1.3.6.1.4.1.232.2.2.4.5.1.7 |
cpqSiMemModulePartNoThe memory module's manufacturer part number.
This field will be a null (size 0) string if the manufacturer
part number is not available.ro DisplayString .1.3.6.1.4.1.232.2.2.4.5.1.8 |
cpqSiMemModuleDateThe memory module date of manufacture.
field octets contents range
===== ====== ====================== ========
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the date of manufacture
is not available. The hour, minute, and second fields will
always be set to 0.ro OCTET STRING .1.3.6.1.4.1.232.2.2.4.5.1.9 |
cpqSiMemModuleSerialNoThe memory module's serial number.
This field will be a null (size 0) string if the serial number
is not available.rw DisplayString .1.3.6.1.4.1.232.2.2.4.5.1.10 |
cpqSiMemModuleECCStatusThis provides the current status of the correctable memory
errors for this memory module.
The following status values are supported:
other(1):
ECC is not supported on this memory module.
ok(2):
The correctable error count is below threshold.
degraded(3):
The correctable error count has exceeded threshold.
degradedModuleIndexUnknown(4):
The correctable error count has exceeded threshold.
The module index not available.ro Enumeration .1.3.6.1.4.1.232.2.2.4.5.1.11 |
cpqSiMemModuleHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the memory module.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.2.2.4.5.1.12 |
cpqSiMemModuleFrequencyThe memory module frequency in MHz. The value zero (0) will
be given if the module frequency cannot be determined.ro INTEGER .1.3.6.1.4.1.232.2.2.4.5.1.13 |
cpqSiMemModuleCellTablePtrIndex for the cell in cpqSeCellTable where the memory board is
installed.ro INTEGER .1.3.6.1.4.1.232.2.2.4.5.1.14 |
cpqSiMemModuleCellStatusThis provides the current status for this memory module.
The following status values are supported:
other(1):
The memory module status is not available
ok(2):
The memory module is active
deconfigured(3):
The memory module is not readyro Enumeration .1.3.6.1.4.1.232.2.2.4.5.1.15 |
cpqSiMemModulePartNoMfgrThe memory module's manufacturer's part number.
This field will be a null (size 0) string if the manufacturer
part number is not available.ro DisplayString .1.3.6.1.4.1.232.2.2.4.5.1.16 |
cpqSiMemModuleSerialNoMfgrThe memory module's manufacturer's serial number.
This field will be a null (size 0) string if the manufacturer
serial number is not available.ro DisplayString .1.3.6.1.4.1.232.2.2.4.5.1.17 |
cpqSiSystemIdThe System ID.
This value indicates the system ID of the system board
in this system. This ID replaces the product ID used in
older machines (cpqSiProductId). A value of 7Eh for the
cpqSiProductId indicates that the cpqSiSystemId should be
used to identify the system. A value of zero (0)
indicates that the system ID function is not supported on this
machine. In this case, the cpqSiProductId should be used to
identify the system.ro INTEGER .1.3.6.1.4.1.232.2.2.4.6 |
cpqSiSystemCpuIdThe System ID : CPU Component.
This value indicates the CPU type of the system board
in this system. A value of zero (0) indicates that the CPU
type cannot be determined.ro INTEGER .1.3.6.1.4.1.232.2.2.4.7 |
cpqSiFlashRomSupportThis value indicates if this system supports flash upgradable
system ROM.ro Enumeration .1.3.6.1.4.1.232.2.2.4.8 |
cpqSiQuickTestRomDateThis value indicates the date of the current quick test ROM
image.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if quick test ROM is not
present. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first.ro OCTET STRING .1.3.6.1.4.1.232.2.2.4.9 |
cpqSiRebootThis object may contain the following values:
notAvailable(1)
the system does not support the reboot functionality.
Setting this object to notAvailable(1) has no effect.
available(2)
the system supports the both reboot to functionalities.
Setting this object to available(2) has no effect.
defaultOnlyAvailable(3)
the system supports the only the default reboot functionality.
Setting this object to available(3) has no effect.
rebootToCpqUtils(2693)
the system will reboot to the System Utilities if
the reboot functionality is available. If possible,
the agent will attempt to gracefully shutdown the
operating system before performing the reboot.
If this functionality is unavailable on this system
then all sets will have no effect.
rebootToDefault(8115)
the system will reboot and allow the default boot
process to occur if the reboot functionality is
available. If possible, the agent will attempt to
gracefully shutdown the operating system before
performing the reboot. If this functionality is
unavailable on this system then all sets will have
no effect.
autoShutdown(9037)
If possible, the agent will attempt to gracefully
shutdown the operating system. The agent will not
preform a reboot.rwdeprecated Enumeration .1.3.6.1.4.1.232.2.2.4.10 |
cpqSiProcMicroPatchTableThis table lists the set of processor microcode patches that
the system ROM contains. During post, the ROM will apply the
appropriate patches to the CPU microcode. Scan this table to
ensure that a patch is being applied to a processor. SEQUENCE OF CpqSiProcMicroPatchEntry .1.3.6.1.4.1.232.2.2.4.11 |
cpqSiProcMicroPatchEntryAn entry describing one microcode patch contained in the system
ROM. CpqSiProcMicroPatchEntry .1.3.6.1.4.1.232.2.2.4.11.1 |
cpqSiProcMicroPatchIndexIndex into the microcode patch table.ro INTEGER .1.3.6.1.4.1.232.2.2.4.11.1.1 |
cpqSiProcMicroPatchIdThe ID of this particular CPU microcode patch.ro INTEGER .1.3.6.1.4.1.232.2.2.4.11.1.2 |
cpqSiProcMicroPatchDateThis value indicates the date of this CPU microcode patch.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
NOTE: Year is stored in packed BCD. The most significant
part is in the second octet. For example:
1995 would be stored as 0x95 0x19.
The hour, minute, and second field will be set to zero (0)
if they are not relevant. The year field is set with the
most significant octet first.ro OCTET STRING .1.3.6.1.4.1.232.2.2.4.11.1.3 |
cpqSiProcMicroPatchFamilyThe valid family/model/step of the processor that this CPU
microcode patch applies to.
field octets contents range
===== ====== ======= =====
1 1 CPU Step 0..255
2 2 CPU Model 0..255
3 3 CPU Family 0..255ro OCTET STRING .1.3.6.1.4.1.232.2.2.4.11.1.4 |
cpqSiPowerMgmtStatusThe state of power management.ro Enumeration .1.3.6.1.4.1.232.2.2.4.12 |
cpqSiRebootFlagsThe Reboot Flags.
This is a collection of flags used to indicate the re-boot
options available. This integer is a bitmap, with each bit
indicating the availability of an option. If the bit is set
to 1, the option is available; otherwise it is not. Multiple
options are allowed.
NOTE: bit 31 is the most significant bit, bit 0 is the least
significant.
Status This is a collection of flags. Each bit has the
following meaning when it is on (1):
Bit 31: Execute Set
Bit 30-6: RESERVED
Bit 5: Boot to ROM Based Setup
Bit 4: RESERVED
Bit 3: Boot to OS
Bit 2: Boot to Utils
Bit 1: Warm Boot
Bit 0: Cold Bootrw INTEGER .1.3.6.1.4.1.232.2.2.4.13 |
cpqSiMemErrorIndexPlaceholder for memory module number for ECC traps.
Represents the number of the memory module for which an ECC status
change has occurred. Set to 65535 if module number not available.ro INTEGER .1.3.6.1.4.1.232.2.2.4.14 |
cpqSiMemECCConditionThis provides the current condition of the correctable memory
errors for the entire memory.
The following status values are supported:
other(1) :
ECC is not supported.
ok(2) :
The correctable error count is below threshold.
degraded(3) :
The correctable error count has exceeded threshold.ro Enumeration .1.3.6.1.4.1.232.2.2.4.15 |
cpqSiMemConfigChangeDataText string for the memory configuration change trap.ro DisplayString .1.3.6.1.4.1.232.2.2.4.16 |
cpqSiServerSystemIdA Server System ID.
This value is used to uniquely identify systems via a unique
ID on systems that do not support the EISA bus.ro DisplayString .1.3.6.1.4.1.232.2.2.4.17 |
cpqSiPowerSchemeThe current active power plan or power scheme of the system.ro Enumeration .1.3.6.1.4.1.232.2.2.4.18 |
cpqSiPowerSchemeNameThe name of current active power plan or power scheme of the
system. When cpqSiPowerScheme has a value of user-defined(6), the
user defined name can be populated here.ro DisplayString .1.3.6.1.4.1.232.2.2.4.19 |
cpqSiCurrentPerformanceStatePointerPointer to cpqSiPerfStateIndex in cpqSiPerfStateTable to indicate the current performance state of the system.ro INTEGER .1.3.6.1.4.1.232.2.2.4.20 |
cpqSiMinPerformanceStateThe slowest performance state by the selected power state policy.ro INTEGER .1.3.6.1.4.1.232.2.2.4.21 |
cpqSiMaxPerformanceStateThe fastest performance state supported by the selected power state policy.ro INTEGER .1.3.6.1.4.1.232.2.2.4.22 |
cpqSiPerfStateTableA table of supported performance states of the system. SEQUENCE OF CpqSiPerfStateEntry .1.3.6.1.4.1.232.2.2.4.23 |
cpqSiPerfStateEntryAn entry describing a supported performance state of the system. CpqSiPerfStateEntry .1.3.6.1.4.1.232.2.2.4.23.1 |
cpqSiPerfStateIndexIndex into the performance state table. cpqSiCurrentPerformanceStatePointer should point to one of these values.ro INTEGER .1.3.6.1.4.1.232.2.2.4.23.1.1 |
cpqSiPerfStatePerformance state number. A unique number assigned to a performance state instance.ro INTEGER (0.. 65535) .1.3.6.1.4.1.232.2.2.4.23.1.2 |
cpqSiPerfStateCpuFrequencyThe processor frequency in megahertz for this performance state instance.ro INTEGER .1.3.6.1.4.1.232.2.2.4.23.1.3 |
cpqSiPerfStateCpuPowerThe processor power setting in milliwatts for this performance state instance.ro INTEGER .1.3.6.1.4.1.232.2.2.4.23.1.4 |
cpqSiTPMmoduleThis field will be populated if TPM module is present in the system board.
other(1)
No record of TPM exist.
absent(2)
TPM module is not present in the system.
presentEnabled(3)
TPM module is present in the system and currently enabled.
presentDisabled(4)
TPM module is present in the system and currently not enabled.ro Enumeration .1.3.6.1.4.1.232.2.2.4.24 |
cpqSiBoardRev OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.5 |
cpqSiCurRevDateThe current board revision configuration date in MM/DD/YY
format. This is the date that the EISA Configuration Utility
was used to define the current configuration. This value will
contain 'N/A' if this system does not support this feature.ro DisplayString .1.3.6.1.4.1.232.2.2.5.1 |
cpqSiPrevRevDateThe previous board revision configuration date in MM/DD/YY
format. This is the date that the EISA Configuration Utility
was used to define the previous configuration. This value will
contain 'N/A' if this system does not support this feature.ro DisplayString .1.3.6.1.4.1.232.2.2.5.2 |
cpqSiBoardRevTableA table of board revision descriptions. SEQUENCE OF CpqSiBoardRevEntry .1.3.6.1.4.1.232.2.2.5.3 |
cpqSiBoardRevEntryA board revision description. CpqSiBoardRevEntry .1.3.6.1.4.1.232.2.2.5.3.1 |
cpqSiBoardRevSlotIndexThe slot in which the board described in this entry resides.
Zero (0) indicates the system board.ro INTEGER .1.3.6.1.4.1.232.2.2.5.3.1.1 |
cpqSiBoardRevIndexA number that uniquely specifies which board in a specific slot
is described in this entry. Zero (0) indicates the main board
in this slot. Any other number indicates a daughter board or a
component of the main board.ro INTEGER .1.3.6.1.4.1.232.2.2.5.3.1.2 |
cpqSiBoardRevIdA description of the board type. The defined types are:
Type
==============
System Board
Processor n (n = the processor number)
Memory n (n = the memory board number)
Slot n (n = the slot the board occupies)
Other types may be defined at a later date.ro DisplayString .1.3.6.1.4.1.232.2.2.5.3.1.3 |
cpqSiBoardRevCurThe current revision for the board described in this entry.
This value will be N/A if there is no current revision
information.ro DisplayString .1.3.6.1.4.1.232.2.2.5.3.1.4 |
cpqSiBoardRevPrevThe revision for the board described in this entry prior to the
current configuration. This value will be N/A if there is no
previous revision information.ro DisplayString .1.3.6.1.4.1.232.2.2.5.3.1.5 |
cpqSiBoardRevHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the board.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.2.2.5.3.1.6 |
cpqSiFirmwareRevTableA table of firmware revision descriptions. SEQUENCE OF CpqSiFirmwareRevEntry .1.3.6.1.4.1.232.2.2.5.4 |
cpqSiFirmwareRevEntryA firmware revision description. CpqSiFirmwareRevEntry .1.3.6.1.4.1.232.2.2.5.4.1 |
cpqSiFirmwareRevIndexLocally-unique index for this entry.ro INTEGER .1.3.6.1.4.1.232.2.2.5.4.1.1 |
cpqSiFirmwareRevDescDescription, e.g. SRM console, ARC console, System BIOS, etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.5.4.1.2 |
cpqSiFirmwareRevStringVersion number, possibly of the form Vx.y or Vx.y-z.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.5.4.1.3 |
cpqSiFirmwareRevCellTablePtrIndex for the cell in cpqSeCellTable where this firmware is locatedrodeprecated INTEGER .1.3.6.1.4.1.232.2.2.5.4.1.4 |
cpqSiFirmwareLocationDescription of which board the firmware is located in.ro DisplayString .1.3.6.1.4.1.232.2.2.5.4.1.5 |
cpqSiFirmwareStatusThe current status for this firmware.ro Enumeration .1.3.6.1.4.1.232.2.2.5.4.1.6 |
cpqSiFirmwareCfgTableTable of soft switches and symbols maintained by the
firmware. May be operating system and/or option-specific
and will certainly be system-specific. This list is
intended to be easily extensible and support arbitrary
datatypes. It includes such switches as powerup options,
default dump device, etc.
Note - the string comparison for svrFwSymbolName is case
insensitive. SEQUENCE OF CpqSiFirmwareCfgEntry .1.3.6.1.4.1.232.2.2.5.5 |
cpqSiFirmwareCfgEntryEach entry represents one variable or symbol maintained by
or stored by some instance of firmware in the system. CpqSiFirmwareCfgEntry .1.3.6.1.4.1.232.2.2.5.5.1 |
cpqSiFirmwareCfgNameThe firmware configuration symbol name as visible from the
console.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.5.5.1.1 |
cpqSiFirmwareCfgValueThe firmware configuration symbol value. Null if none
or unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.5.5.1.2 |
cpqSiRackServer OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.6 |
cpqSiRackServerShutdownRoleThis entry describes this system's role in a rack-mounted
uninterruptible power supply family. The master both
communicates with the UPS and derives its power from the
UPS. The slave derives its power from the UPS, but does
not communicate with it.rw Enumeration .1.3.6.1.4.1.232.2.2.6.1 |
cpqSiRackServerMasterNameThis entry describes the name of the master server in a
rack-mounted uninterruptible power supply family. A slave
system would communicate with this server to derive UPS
status.rw DisplayString .1.3.6.1.4.1.232.2.2.6.2 |
cpqSiVideo OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.7 |
cpqSiVideoEdidRawThe raw value returned from the video EDID function.rodeprecated OCTET STRING .1.3.6.1.4.1.232.2.2.7.1 |
cpqSiVideoDescThe manufacturer and model description of the video display.rodeprecated DisplayString .1.3.6.1.4.1.232.2.2.7.2 |
cpqSiVideoSerialNumberThe serial number of the video display.rodeprecated DisplayString .1.3.6.1.4.1.232.2.2.7.3 |
cpqSiVideoManufactureDateThe date of manufacture of the video display in the following
format:
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date. The date information that is given resolves to a year
and week, so the hour, minute, and second field will be set to 0,
the month and day fields will give the monday of the week of
manufacture.rodeprecated OCTET STRING .1.3.6.1.4.1.232.2.2.7.4 |
cpqSiVideoHeightThe maximum image height of the video display in centimetersrodeprecated INTEGER .1.3.6.1.4.1.232.2.2.7.5 |
cpqSiVideoWidthThe maximum image width of the video display in centimetersrodeprecated INTEGER .1.3.6.1.4.1.232.2.2.7.6 |
cpqSiVideoMaxHorPixelThe number of horizontal pixels in the highest resolution video
mode supported.rodeprecated INTEGER .1.3.6.1.4.1.232.2.2.7.7 |
cpqSiVideoMaxVertPixelThe number of vertical pixels in the highest resolution video
mode supported.rodeprecated INTEGER .1.3.6.1.4.1.232.2.2.7.8 |
cpqSiVideoMaxRefreshRateThe video refresh rate in Hz of the highest resolution video
mode supported.rodeprecated INTEGER .1.3.6.1.4.1.232.2.2.7.9 |
cpqSiMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.8 |
cpqSiMonitorOverallConditionThis value specifies the overall condition of the system's
monitor(s).
The following conditions are supported:
other(1)
The monitor does not support fault reporting or condition is
unknown.
ok(2)
The monitor is operating OK.
degraded(3)
The monitor has detected a fault. The monitor is still useable
but action should be taken to return the monitor to ok.
failed(4)
The monitor has detected a fault. The monitor will not
be useable. Action should be taken to replace the monitor.ro Enumeration .1.3.6.1.4.1.232.2.2.8.1 |
cpqSiMonitorTableA table of all video monitor descriptions connected to this
system. SEQUENCE OF CpqSiMonitorEntry .1.3.6.1.4.1.232.2.2.8.2 |
cpqSiMonitorEntryA video monitor description. CpqSiMonitorEntry .1.3.6.1.4.1.232.2.2.8.2.1 |
cpqSiMonitorIndexA unique index for each video display connected to the system.ro INTEGER .1.3.6.1.4.1.232.2.2.8.2.1.1 |
cpqSiMonitorEdidRawThe raw value returned from the video EDID function.ro OCTET STRING .1.3.6.1.4.1.232.2.2.8.2.1.2 |
cpqSiMonitorDescThe manufacturer and model description of the video display.ro DisplayString .1.3.6.1.4.1.232.2.2.8.2.1.3 |
cpqSiMonitorSerialNumberThe serial number of the video display.ro DisplayString .1.3.6.1.4.1.232.2.2.8.2.1.4 |
cpqSiMonitorManufactureDateThe date of manufacture of the video display in the following
format:
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date. The date information that is given resolves to a year
and week, so the hour, minute, and second field will be set to 0,
the month and day fields will give the monday of the week of
manufacture.ro OCTET STRING .1.3.6.1.4.1.232.2.2.8.2.1.5 |
cpqSiMonitorHeightThe maximum image height of the video display in centimetersro INTEGER .1.3.6.1.4.1.232.2.2.8.2.1.6 |
cpqSiMonitorWidthThe maximum image width of the video display in centimetersro INTEGER .1.3.6.1.4.1.232.2.2.8.2.1.7 |
cpqSiMonitorMaxHorPixelThe number of horizontal pixels in the highest resolution video
mode supported.ro INTEGER .1.3.6.1.4.1.232.2.2.8.2.1.8 |
cpqSiMonitorMaxVertPixelThe number of vertical pixels in the highest resolution video mode
supported.ro INTEGER .1.3.6.1.4.1.232.2.2.8.2.1.9 |
cpqSiMonitorMaxRefreshRateThe video refresh rate in Hz of the highest resolution video mode
supported.ro INTEGER .1.3.6.1.4.1.232.2.2.8.2.1.10 |
cpqSiMonitorManufacturerThe manufacturer of the video display.ro DisplayString .1.3.6.1.4.1.232.2.2.8.2.1.11 |
cpqSiMonitorThermalConditionThis provides the condition of the monitor's internal temperature.
This value will be one of the following:
other(1)
Monitor thermal fault reporting is not supported by this monitor
or the Insight Agent does not recognize the status. You may
need to upgrade your software.
ok(2)
The internal temperature is within normal limits.
degraded(3)
The internal temperature is outside normal operating range.ro Enumeration .1.3.6.1.4.1.232.2.2.8.2.1.12 |
cpqSiMonitorOperationalConditionThis provides the condition of the monitor's operational features.
This condition value will be one of the following:
other(1)
Monitor operational fault reporting is not supported by this
monitor or the Insight Agent does not recognize the status.
You may need to upgrade your software.
ok(2)
The monitor is operating within normal limits.
degraded(3)
The monitor is not functioning within normal operating limits.
At least one of the operational features has become degraded.
failed(4)
The monitor is not functioning within normal operating limits.
At least one of the operational features has failed causing the
monitor to not be usable. The monitor should be replaced.ro Enumeration .1.3.6.1.4.1.232.2.2.8.2.1.13 |
cpqSiMonitorStatusThis provides the status of the monitor's fault reporting features.
This status value will be one of the following:
other(1)
Monitor fault reporting is not supported by this monitor or the
Insight Agent does not recognize the status. You may need to
upgrade your software.
unknown(2)
The monitor status is unknown because the monitor is
either in power saving mode or it has been turned off.
ok(3)
The monitor is operating within normal limits.
thermalDegraded(4)
The monitor's internal temperature is not functioning within
normal operating limits.
operationalFailure(5)
The monitor is not functioning within normal operating limits.
At least one of the operational features has failed.
The monitor should be replaced.ro Enumeration .1.3.6.1.4.1.232.2.2.8.2.1.14 |
cpqSiHotPlugSlot OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.9 |
cpqSiHotPlugSlotSupportedThis value specifies if this system supports the Hot
Pluggable Slot feature.ro Enumeration .1.3.6.1.4.1.232.2.2.9.1 |
cpqSiHotPlugSlotConditionThis value specifies the overall condition of the Hot Plug
Slot feature.
The Hot Plug condition is set as follows:
other(1)
When Hot Plug Slots are not supported or condition is unknown.
ok(2)
If there are no hot plug slots with a condition of degraded
or failed.
degraded(3)
If there are degraded slot entries but none failed.
failed(4)
If there are failed slot entries.ro Enumeration .1.3.6.1.4.1.232.2.2.9.2 |
cpqSiHotPlugSlotChangeCountThis value will be incremented each time a hot plug event
occurs resulting in a change in the hot plug slot table.ro INTEGER .1.3.6.1.4.1.232.2.2.9.3 |
cpqSiHotPlugSlotTableA list of Hot Plug Slot information entries. SEQUENCE OF CpqSiHotPlugSlotEntry .1.3.6.1.4.1.232.2.2.9.4 |
cpqSiHotPlugSlotEntryA description of a Hot Plug Slot. CpqSiHotPlugSlotEntry .1.3.6.1.4.1.232.2.2.9.4.1 |
cpqSiHotPlugSlotChassisThe Chassis where this hot plug slot resides.ro INTEGER .1.3.6.1.4.1.232.2.2.9.4.1.1 |
cpqSiHotPlugSlotIndexThe slot within the chassis for this hot plug slot.ro INTEGER .1.3.6.1.4.1.232.2.2.9.4.1.2 |
cpqSiHotPlugSlotBoardPresentThis value indicates whether a board is present(2) in or
absent(3) from the slot. A value of other(1) indicates
the information could not be obtained.ro Enumeration .1.3.6.1.4.1.232.2.2.9.4.1.3 |
cpqSiHotPlugSlotPowerStateThis value is set to powerOn(2) when power is being supplied
to the slot and powerOff(3) when power is not being supplied.
A value of other(1) indicates the information could not be
obtained.ro Enumeration .1.3.6.1.4.1.232.2.2.9.4.1.4 |
cpqSiHotPlugSlotBoardConditionThis value specifies the condition of the hot plug slot.
The hot plug condition is set as follows:
other(1)
When the condition could not be determined.
ok(2)
The slot is powered up and operating normally.
degraded(3)
If the board in the slot is not fully functioning.
failed(4)
If the slot is failed for any reason. See the status code
for more information on the failure.ro Enumeration .1.3.6.1.4.1.232.2.2.9.4.1.5 |
cpqSiHotPlugSlotErrorStatusThis value specifies the status of the hot plug slot.
The hot plug slot status is set as follows:
noError(1)
The slot is operating normally.
generalError(2)
A general error occurred.
wrongRevision(3)
The revision of the replacement adapter was different from
the original adapter.
wrongBoard(4)
The model of the replacement adapter was different from the
original adapter.
cannotConfig(5)
The adapter could not be configured.
powerFault(6)
A power fault occurred for the slot.
unexpectedPowerLoss(7)
Power was unexpectedly lost from the slot.
wrongSpeed(8)
The adapter cannot be run at the current bus speed.
functionlFailure(9)
The adapter is not functioning correctly. This may
be caused by a cabling problem.ro Enumeration .1.3.6.1.4.1.232.2.2.9.4.1.6 |
cpqSiHotPlugSlotHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the hot plug slot.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.2.2.9.4.1.7 |
cpqSiSystemBattery OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.10 |
cpqSiSystemBatteryOverallConditionThis value specifies the overall condition of all of the
system batteries.
The following conditions are supported:
other(1)
The system does not use system batteries or the battery
condition is unknown.
ok(2)
All System Batteries are operating OK.
degraded(3)
One or more of the System Batteries has degraded. The
degraded battery will continue to function but should be
replaced.
failed(4)
One of more of the System Batteries has failed. The failed
battery is no longer usable. Action should be taken to replace
the battery.ro Enumeration .1.3.6.1.4.1.232.2.2.10.1 |
cpqSiSysBatteryTableA table of System Batteries. SEQUENCE OF CpqSiSysBatteryEntry .1.3.6.1.4.1.232.2.2.10.2 |
cpqSiSysBatteryEntryA system battery description. CpqSiSysBatteryEntry .1.3.6.1.4.1.232.2.2.10.2.1 |
cpqSiSysBatteryIndexA unique index for this battery entry.ro INTEGER .1.3.6.1.4.1.232.2.2.10.2.1.1 |
cpqSiSysBatteryModelThe model name for this battery.ro DisplayString .1.3.6.1.4.1.232.2.2.10.2.1.2 |
cpqSiSysBatterySerialNumThe serial number for this battery.ro DisplayString .1.3.6.1.4.1.232.2.2.10.2.1.3 |
cpqSiSysBatteryAssetTagThis is the customer changeable battery identifier that is set
to this system battery's serial number at the time of
manufacture.
The string will be empty if the battery does support
this function.ro DisplayString .1.3.6.1.4.1.232.2.2.10.2.1.4 |
cpqSiSysBatteryManufacturerThe battery's manufacturer's name.
The string will be empty if the battery does support
this function.ro DisplayString .1.3.6.1.4.1.232.2.2.10.2.1.5 |
cpqSiSysBatteryDateThe battery's manufacture date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first.
The string will be empty if the battery does support
this function.ro OCTET STRING .1.3.6.1.4.1.232.2.2.10.2.1.6 |
cpqSiSysBatterySmartVersionThe Smart Battery Data Specification version number supported by this
battery.
The string will be empty if the system battery does support
this function.ro DisplayString .1.3.6.1.4.1.232.2.2.10.2.1.7 |
cpqSiSysBatteryConditionThis provides the current condition of this system battery.
The following status values are supported:
other(1)
The battery does not support condition monitoring or
the Insight Agent cannot determine condition.
ok(2)
The battery is operating normally. No user action is
required.
degraded(3)
The battery is degraded. The battery is still usable
but should be replaced.
failed(4)
The battery has failed. The battery is no longer
usable and should be replaced soon.ro Enumeration .1.3.6.1.4.1.232.2.2.10.2.1.8 |
cpqSiSysBatteryStatusThis provides the current status of the battery.
The following status values are supported:
other(1):
This battery does not support status reporting.
ok(2):
The battery is operating ok.
User Action: No action required.
capacityDegraded(3):
Significant battery degradation has occurred.
The battery can no longer be fully recharged.
User Action:
If using multiple batteries, run the Power
Conservation Utility to identify the battery
location. Contact your System Administrator or
Authorized Reseller to order a replacement
battery.
chargeFault(4):
One or more batteries are not functioning properly.
User Action:
Make sure all batteries are operating in the
recommended temperature range. Check for foreign
objects in the battery slots. Remove and reinsert all
batteries to resume normal battery operation.
Contact your System Administrator or Authorized
Reseller if you are still experiencing problems.
batteryFailure(5):
The battery has failed and must be replaced.
User Action:
Contact your System Administrator or Authorized
Reseller to order a replacement battery. Recycle your
old battery. For proper disposal information, refer
to the documentation that came with your computer.ro Enumeration .1.3.6.1.4.1.232.2.2.10.2.1.9 |
cpqSiSysBatteryChemistryThe chemistry of the battery.ro Enumeration .1.3.6.1.4.1.232.2.2.10.2.1.10 |
cpqSiSysBatteryRemainingCapThis is a percentage of the battery's remaining capacity
from its design capacity.
If this attribute is not supported, 65535 is returned.ro INTEGER .1.3.6.1.4.1.232.2.2.10.2.1.11 |
cpqSiSysBatteryFirmwareRevisionThis is the revision level of the firmware on the battery.
If this attribute is not supported, 255 is returned.ro INTEGER .1.3.6.1.4.1.232.2.2.10.2.1.12 |
cpqSiSysBatteryHardwareRevisionThis is the revision level of the hardware on the battery.
If this attribute is not supported, 255 is returned.ro INTEGER .1.3.6.1.4.1.232.2.2.10.2.1.13 |
cpqSiSysBatteryFullCapThis is the mWatt-Hours of the battery's Full capacity on
the current charge.
If this attribute is not supported, 65535 is returned.ro INTEGER .1.3.6.1.4.1.232.2.2.10.2.1.14 |
cpqSiSysBatteryDesignCapThis is the mWatt-Hours of the battery's design capacity as
specified by the manufacturer.
If this attribute is not supported, 65535 is returned.ro INTEGER .1.3.6.1.4.1.232.2.2.10.2.1.15 |
cpqSiSysBatteryHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the battery.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.2.2.10.2.1.16 |
cpqSiDockingStation OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.11 |
cpqSiDockingStationStatusThis value specifies the connection of the computer
system to a docking station.
The following connection states are supported:
notSupported(1)
This system does not interface to a docking station.
docked(2)
This system is connected to a docking station.
undocked(3)
This system is not connect to a docking station.ro Enumeration .1.3.6.1.4.1.232.2.2.11.1 |
cpqSiDockingStationSerialNumThe serial number of the docking station.
The string will be empty if the docking station does not support a
serial or the system does not interface to a docking station.ro DisplayString .1.3.6.1.4.1.232.2.2.11.2 |
cpqSiDockingStationModelThe model name of the docking station.
The string will be empty if the docking station does not report the
model name or the system does not interface to a docking station.ro DisplayString .1.3.6.1.4.1.232.2.2.11.3 |
cpqSiDockingStationAssetTagThis is a customer changeable identifier that is set to the docking
station serial number at the time of manufacture.
The string will be empty if the docking station does not report an
asset tag or the system does not interface to a docking station.ro DisplayString .1.3.6.1.4.1.232.2.2.11.4 |
cpqSiFru OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.12 |
cpqSiFruTableTable of Field Replaceable Units of system, providing
inventory and asset control information. This table is
referenced from logical hardware descriptions elsewhere in
the MIB. SEQUENCE OF CpqSiFruEntry .1.3.6.1.4.1.232.2.2.12.1 |
cpqSiFruEntryEach entry represents a Field Replaceable Unit (FRU) of hardware. CpqSiFruEntry .1.3.6.1.4.1.232.2.2.12.1.1 |
cpqSiFruIndexA locally-unique index value.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.1 |
cpqSiFruTypeGeneral category of the type of FRU that this is.ro Enumeration .1.3.6.1.4.1.232.2.2.12.1.1.2 |
cpqSiFruDescrMore detailed description of FRU type, if known.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.3 |
cpqSiFruVendorManufacturer name or ID.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.4 |
cpqSiFruPartNumberNumber by which this unit is orderable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.5 |
cpqSiFruRevisionVersion number of this unit. If artwork level is available, it will
appear as 'Artwork: XXX' following FRU version portion.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.6 |
cpqSiFruFirmwareRevisionThe revision of the firmware, if any. Otherwise null.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.7 |
cpqSiFruSerialNumberThe serial number of this unit's instance.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.8 |
cpqSiFruAssetNoThe asset number for this unit. This string may be limited.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.9 |
cpqSiFruClassRepresents the status category of the unit.ro Enumeration .1.3.6.1.4.1.232.2.2.12.1.1.10 |
cpqSiFruSlotNumberPhysical slot number of FRU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.12.1.1.11 |
cpqSiFruSubAssemblyNumberSubassembly containing this FRU. From FRU V5.0.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.12 |
cpqSiFruAssemblyNumberAssembly containing this FRU. From FRU V5.0.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.13 |
cpqSiFruChassisNumberChassis containing this FRU. From FRU V5.0.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.14 |
cpqSiFruPositionNumberPosition in Chassis to help locate FRU. From FRU V5.0.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.15 |
cpqSiFruCabinetIDNumberCabinet number containing this FRU. From FRU V5.0.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.16 |
cpqSiFruSiteLocationSite code for system containing this FRU. From FRU V5.0.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.17 |
cpqSiFruDiagStatusUse system status values to describe current state of the
FRU.ro Enumeration .1.3.6.1.4.1.232.2.2.12.1.1.18 |
cpqSiFruExtendedDiagStatusDiagnostic Status value returned by Device Specific
diagnostics. Usually through a diagnostic status register
on the device. See product manual for bit descriptions.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.19 |
cpqSiFruCellTablePtrIndex for the cell in cpqSeCellTable where this FRU is physically located.ro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.20 |
cpqSiFruIOCTablePtrIndex for the I/O Chassis in cpqSeIOCTablePtr where this FRU is physically locatedro INTEGER .1.3.6.1.4.1.232.2.2.12.1.1.21 |
cpqSiFruFileIdThis represents the FRU file identifierro DisplayString .1.3.6.1.4.1.232.2.2.12.1.1.22 |
cpqSiFruScanRevThis represents FRU scan revisionro DisplayString .1.3.6.1.4.1.232.2.2.12.1.1.23 |
cpqSiRackEnclosure OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.13 |
cpqSiRackEnclosureMgrTableTable of possible rack and/or enclosure based systems. SEQUENCE OF CpqSiRackEnclosureMgrEntry .1.3.6.1.4.1.232.2.2.13.1 |
cpqSiRackEnclosureMgrEntryA entry for a rack and/or enclosure based system. CpqSiRackEnclosureMgrEntry .1.3.6.1.4.1.232.2.2.13.1.1 |
cpqSiRackEnclosureMgrIndexA locally-unique index value.ro INTEGER .1.3.6.1.4.1.232.2.2.13.1.1.1 |
cpqSiRackEnclosureMgrTypeThis value specifies the type of enclosure management.
other(1)
When the type not be determined.
noEnclosureManagement(2)
The server is part of a rack/enclosure managed system, but there
is no dedicated enclosure manager.
enclosureManagement(3)
The server is part of a rack/enclosure managed system with a
dedicated enclosure manager.
onboardAdminManagement(4)
The server is part of a rack/enclosure managed system with a
onboard Administrator.
multiboardchassis(5)
The server is part of a nultiple board chassis.ro Enumeration .1.3.6.1.4.1.232.2.2.13.1.1.2 |
cpqSiRackEnclosureMgrIpAddrThe IP address of the rack enclosure manager.
The string will be empty if the enclosure does not report the
information or it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.3 |
cpqSiRackEnclosureMgrWebLinkThe web link to the enclosure managers web based management
information for the enclosure.
The string will be empty if the enclosure does not report the
information or it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.4 |
cpqSiRackEnclosureMgrConditionThe overall condition of the Enclosure. For more detailed
status information, follow the cpqSiEnclosureMgrWebLink through
the Web Management Agent interface.
other(1)
This is the default condition for systems when
cpqSiRackEnclosureMgrType has a value of
noEnclosureManagement(2).
When cpqSiRackEnclosureMgrType has a value of
enclosureManagement(3), this indicates the status of the
enclosure manager could not be determined.
ok(2)
The enclosure manager is in an ok state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure.
degraded(3)
The enclosure manager is in a degraded state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure.
failed(4)
The enclosure manager is in a failed state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure.ro Enumeration .1.3.6.1.4.1.232.2.2.13.1.1.5 |
cpqSiRackEnclosureMgrSerialNumberThe serial number of the enclosure.
The string will be empty if the enclosure does not report the
information or it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.6 |
cpqSiRackEnclosureMgrModelThe model name of the enclosure.
The string will be empty if it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.7 |
cpqSiRackEnclosureMgrNameThe name of the enclosure. This name logically groups together the
Blade servers installed in the same enclosure and it is shared
with the other servers in the enclosure.
The string will be empty if it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.8 |
cpqSiRackEnclosureMgrFwRevThe Firmware revision of the Enclosure Manager/Onboard Administrator.
The string will be empty if it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.9 |
cpqSiRackEnclosureMgrProductIDThe Enclosure product identifier. The string will be empty
if it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.10 |
cpqSiRackEnclosureMgrUUIDThe Enclosure unique identifier. The string will be empty
if it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.13.1.1.11 |
cpqSiServerBlade OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.14 |
cpqSiServerBladeEnclosureBayNumberThis value specifies the enclosure bay number occupied by the blade.
In case of a blade occupying multiple bays, this will be the lowest
enclosure bay number of all the bay numbers occupied by this baldero INTEGER .1.3.6.1.4.1.232.2.2.14.1 |
cpqSiServerBladeHeightBlade height is the Blade length.
unknown(1)
This indicates it could not be determined.
halfHeightBlade(2)
This indicates a half-height server Blade.
fullHeightBlade(3)
This indicates a full-height server Blade.ro Enumeration .1.3.6.1.4.1.232.2.2.14.2 |
cpqSiServerBladeWidthWidth of the Blade in terms of Enclosure Bays. This pertain to the
Blade side that connects to the enclosure backplane.ro Enumeration .1.3.6.1.4.1.232.2.2.14.3 |
cpqSiRack OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.15 |
cpqSiRackNameThe rack name. This name is used to logically group together
enclosures in a rack and it is shared with other enclosures
in the rack.
The string will be empty if it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.15.1 |
cpqSiRackUUIDThe rack unique identifier. The string will be empty
if it could be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.15.2 |
cpqSiMP OBJECT IDENTIFIER .1.3.6.1.4.1.232.2.2.16 |
cpqSiMPHostNameThe host name of the Management Processor.
The string will be empty if it could not be determined.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.2.2.16.1 |
cpqSiMPHealthStatusThe health status of the Management Processor.ro Enumeration .1.3.6.1.4.1.232.2.2.16.2 |