COMPAQ-AGENT-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for COMPAQ-AGENT-MIB.
116
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
116 total| Object Name |
|---|
agentGeneralMgmt OBJECT IDENTIFIER .compaq-common-mgmt.1 |
RFC1155-SMI Unknown .compaq-common-mgmt.1 |
agentBasicInfo OBJECT IDENTIFIER .compaq-common-mgmt.1.1 |
agentMgmtProtocolCapabilityThe network management protocol(s) supported by this agent.ro Enumeration .compaq-common-mgmt.1.1.1 |
agentMibCapabilityTableA list of MIB capability entries supported by this agent. SEQUENCE OF AgentMibCapabilityEntry .compaq-common-mgmt.1.1.2 |
agentMibCapabilityEntryA MIB capability entry contains objects describing a particular MIB
supported by this agent. AgentMibCapabilityEntry .compaq-common-mgmt.1.1.2.1 |
agentMibCapabilityIndexA list of agentMibCapabilityDescr entries.ro INTEGER .compaq-common-mgmt.1.1.2.1.1 |
agentMibCapabilityDescrThe name of the MIB supported by the agent.ro DisplayString .compaq-common-mgmt.1.1.2.1.2 |
agentMibCapabilityVersionThe version of the MIB specified in this entry.ro INTEGER .compaq-common-mgmt.1.1.2.1.3 |
agentMibCapabilityTypeThe type of the MIB specified in this entry.ro Enumeration .compaq-common-mgmt.1.1.2.1.4 |
agentStatusConsoleInUseThis indicates whether console is currently in-use.ro Enumeration .compaq-common-mgmt.1.1.3 |
agentStatusSaveCfgThis indicates the status of the device configuration.
other(1) - this entry is currently in use but the conditions
under which it will remain so are different from each
of the following values.
proceeding(2) - the device configuration is being currently saved into the NV-RAM.
completed(3) - all of the device configuration parameters have been
saved into NV-RAM.
changed-not-save(4) - some of the device configuration parameters have
been changed but not saved into NV-RAM.
failed(5) - The process to save device configuration is failed.ro Enumeration .compaq-common-mgmt.1.1.4 |
agentSwitchMfgDateThe switch manufacturing date and time.ro DisplayString .compaq-common-mgmt.1.1.5 |
agentSwitchFirmwareMfgDateThe switch firmware manufacturing date and time.ro DisplayString .compaq-common-mgmt.1.1.6 |
agentBasicConfig OBJECT IDENTIFIER .compaq-common-mgmt.1.2 |
agentBscSwFileTableA list of MIB Basic Config entries supported file Update by this agent. SEQUENCE OF AgentBscSwFileEntry .compaq-common-mgmt.1.2.1 |
agentBscSwFileEntryA basic config entry contains objects describing a particular MIB
supported by this agent. AgentBscSwFileEntry .compaq-common-mgmt.1.2.1.1 |
agentBscSwFileIndexThe table index for the file entryrw INTEGER .compaq-common-mgmt.1.2.1.1.1 |
agentBscSwFileDscrThe description for the purpose of the software file in this entry.
Note:
For system which does not support change of this object, setting value to
this object will cause the system to return bad-value error message.rw DisplayString .compaq-common-mgmt.1.2.1.1.2 |
agentBscSwFileAddrThe IP address where the File to be downloaded is located, or the IP address
where the file will be uploaded to.rw IpAddress .compaq-common-mgmt.1.2.1.1.3 |
agentBscSwFileTransferTypeThe channel through which the file will be downloaded or uploaded.
Note:
For system which does not support all channels, setting value to the unsupported
channel will cause the system to return bad-value error message.rw Enumeration .compaq-common-mgmt.1.2.1.1.4 |
agentBscSwFileThe name of the file to be downloaded from the TFTP server, or to be uploaded
to.rw DisplayString .compaq-common-mgmt.1.2.1.1.5 |
agentBscSwFileLocateIdThis object describes the type of the file.
runtime-code(1),
log-file(2),
cfg-file(3)
Note:
For system which does not support change of this object, setting value to
this object will cause the system to return bad-value error message.rw INTEGER .compaq-common-mgmt.1.2.1.1.6 |
agentBscSwFileLoadTypeThis object provides the user to select download or upload function for the file.
Note:
For system which does not support change of this object, setting value to
this object will cause the system to return bad-value error message.rw Enumeration .compaq-common-mgmt.1.2.1.1.7 |
agentBscSwFileCtrlThis object provides the user to download runtime software. The setting
will take effect when the system is restart. See Note(1) below
Note:
For system which does not support change of this object to some value,
setting object to these values cause the system to return
bad-value error message.rw Enumeration .compaq-common-mgmt.1.2.1.1.8 |
agentBscFileServerTftpPortThe IP port used by the TFTP server.rw INTEGER .compaq-common-mgmt.1.2.1.1.9 |
agentBscSwFileTimeConfiguration/firmware file last saved Date/Time, NULL if unknown.
Unknown if time has not been set by SNTP or manual entry when the
configuration/firmware file was savedro DisplayString .compaq-common-mgmt.1.2.1.1.10 |
agentBscSwFileStatusStatus of last download attempt. See trap switchFileInvalid.
Read-only initialized to NULLro DisplayString .compaq-common-mgmt.1.2.1.1.11 |
agentFileTransferThis object will execute the download or upload action. If start(2), it will
begin to download/upload, but no reset as follow. If start-and-reset(3), then
the reset will active after download or upload. No action if(4).
Note:
Because these funiction will be limited by the system support. Some of the
select item will invalid. When one of the item user select,it will response with
bad-value status.rwobsolete Enumeration .compaq-common-mgmt.1.2.2 |
agentSystemResetThis object indicates the agent system reset state. Setting this
object to no-reset(4) has no effect. Setting this object to
cold-start(2) or warm-start(3) will reset the agent. The agent
always returns no-reset(4) when this object is read.rw Enumeration .compaq-common-mgmt.1.2.3 |
agentRs232PortConfigThis object indicates the RS-232C mode while device restart.rw Enumeration .compaq-common-mgmt.1.2.4 |
agentOutOfBandBaudRateConfigThis object allows user to specify out_of_band baud rate. It will take effect
when the system is restart.
Note:
Because these funiction will be limited by the system support. Some of the
select item will invalid. When one of the item user select,it will response with
bad-value status.rwobsolete Enumeration .compaq-common-mgmt.1.2.5 |
agentSaveCfgAs the object is set to 'set(3)', the current device configuration will be saved
into to NV-RAM.rw Enumeration .compaq-common-mgmt.1.2.6 |
agentIpProtoConfig OBJECT IDENTIFIER .compaq-common-mgmt.1.3 |
agentIpNumOfIfThe total number of IP interfaces supported by this agent.ro INTEGER .compaq-common-mgmt.1.3.1 |
agentIpTftpServerAddrThe IP Address of TFTP Server.rwobsolete IpAddress .compaq-common-mgmt.1.3.2 |
agentIpGetIpFromThis object indicates whether the agent get its system IP address
from Bootp/DHCP server at start up.rw Enumeration .compaq-common-mgmt.1.3.3 |
agentIpTrapManager OBJECT IDENTIFIER .compaq-common-mgmt.1.4 |
agentIpTrapManagerTableA list of trap managers to which SNMP traps will be sent. SEQUENCE OF AgentIpTrapManagerEntry .compaq-common-mgmt.1.4.1 |
agentIpTrapManagerEntryEach entry contains the particular trap manager settings. AgentIpTrapManagerEntry .compaq-common-mgmt.1.4.1.1 |
agentIpTrapManagerIpAddrThe IP address where SNMP traps will be destined forro IpAddress .compaq-common-mgmt.1.4.1.1.1 |
agentIpTrapManagerCommThe community string used to encode SNMP trap packet to be sent to the trap
manager.rw DisplayString .compaq-common-mgmt.1.4.1.1.2 |
agentIpTrapManagerStatusThis object indicates whether or not the trap should be sent to
this trap manager.rw Enumeration .compaq-common-mgmt.1.4.1.1.3 |
agentConsoleModeManager OBJECT IDENTIFIER .compaq-common-mgmt.1.5 |
agentConsoleModeManagerDataBitsThe DataBits for console mode, If the agentRs232PortConfig change to console mode
then the device will use this group to make a setup for console value and
agentSlipModeManager group will deactive automatically.rw Enumeration .compaq-common-mgmt.1.5.1 |
agentConsoleModeManagerStopBitsThe Stop Bits for console moderw Enumeration .compaq-common-mgmt.1.5.2 |
agentConsoleModeManagerParityThe Parity for console mode, If the agentRs232PortConfig change to console mode
then the device will use this group to make a setup for console value and
agentSlipModeManager group will deactive automatically.rw Enumeration .compaq-common-mgmt.1.5.3 |
agentConsoleModeManagerBaudRateThe transmit rate for console mode.rw Enumeration .compaq-common-mgmt.1.5.4 |
agentSlipModeManager OBJECT IDENTIFIER .compaq-common-mgmt.1.6 |
agentSlipModeManagerLocalIPThe Local IP address for slip mode, If the agentRs232PortConfig change to out-of-band mode
then the device will use this group to make a setup for slip value and agentConsoleModeManager
group will deactive automatically.rw IpAddress .compaq-common-mgmt.1.6.1 |
agentSlipModeManagerRemoteIPThe Remote IP address for slip moderw IpAddress .compaq-common-mgmt.1.6.2 |
agentSlipModeManagerMTUThe MTU Value for Slip Moderw Enumeration .compaq-common-mgmt.1.6.3 |
agentSlipModeManagerBaudRateThe MTU Value for Slip Moderw Enumeration .compaq-common-mgmt.1.6.4 |
agentSNTP OBJECT IDENTIFIER .compaq-common-mgmt.1.7 |
agentSNTPStateThis object enable/disable the SNTP function.rw Enumeration .compaq-common-mgmt.1.7.1 |
agentSNTPTimeSourcethe SNTP server status for time source changingro Enumeration .compaq-common-mgmt.1.7.2 |
agentSNTPServer1IPAddrConfigure the SNTP server #1 IP addressrw IpAddress .compaq-common-mgmt.1.7.3 |
agentSNTPServer2IPAddrConfigure the SNTP server #2 IP addressrw IpAddress .compaq-common-mgmt.1.7.4 |
agentSNTPTimeZoneLocal time offset in minutes from GMT.rw INTEGER (-779..839) .compaq-common-mgmt.1.7.5 |
agentSNTPPollIntervalUpdate time in seconds from SNTP server.rw INTEGER .compaq-common-mgmt.1.7.6 |
agentSNTPCurrentTimethe mandatory network time was got from the SNTP serverro DisplayString .compaq-common-mgmt.1.7.7 |
agentSNTPUpTimeThe time (in second) since the network management portion
of the system was last re-initialized. It is the same as
sysUptime.ro INTEGER .compaq-common-mgmt.1.7.8 |
agentSNTPBootTimeThe boot time of the switch is equal to subtract systemUpTime
from agentSNTPNetworkTimero DisplayString .compaq-common-mgmt.1.7.9 |
agentDST OBJECT IDENTIFIER .compaq-common-mgmt.1.8 |
agentDSTStatusAn indication of whether the DST(Daylight Saving Time) feature
is enabled on this device. When this object is set to repeating(2),
or annual(3) then all the other objects are set to default values.
When this object is set to disable(1), then all the other objects
are not instantiated and the DST feature is disabledrw Enumeration .compaq-common-mgmt.1.8.1 |
agentDSTOffsetThe value of this object indicates number of minutes to add
or to subtract during DST. This object is not instantiated
when agentDSTStatus object is set to false.rw INTEGER ( 0 .. 1440) .compaq-common-mgmt.1.8.2 |
agentDSTRepeatingStartMonththe repeating start month (January = 1, .., Decenber = 12)rw INTEGER (1 .. 12) .compaq-common-mgmt.1.8.3 |
agentDSTRepeatingStartWhichDayWhichDay means
0 = last week
1 = 1st week
2 = 2nd week
3 = 3th week
4 = 4th weekrw INTEGER (0 .. 4) .compaq-common-mgmt.1.8.4 |
agentDSTRepeatingStartDayOfWeekDay Of Week
Sun = 1
Mon = 2
Tue = 3
Wed = 4
Thu = 5
Fri = 6
Sat = 7rw INTEGER (1 .. 7 ) .compaq-common-mgmt.1.8.5 |
agentDSTRepeatingStartHourthe hour of the DST Repeating Start Day of Weekrw INTEGER (0 .. 23) .compaq-common-mgmt.1.8.6 |
agentDSTRepeatingStartMinutethe minute of the DST Repeating Start Hourrw INTEGER (0 .. 59) .compaq-common-mgmt.1.8.7 |
agentDSTRepeatingEndMonththe repeating end month (January = 1, .., Decenber = 12)rw INTEGER (1 .. 12) .compaq-common-mgmt.1.8.8 |
agentDSTRepeatingEndWhichDayWhichDay means
0 = last week
1 = 1st week
2 = 2nd week
3 = 3th week
4 = 4th weekrw INTEGER (0 .. 4) .compaq-common-mgmt.1.8.9 |
agentDSTRepeatingEndDayOfWeekDay Of Week
Sun = 1
Mon = 2
Tue = 3
Wed = 4
Thu = 5
Fri = 6
Sat = 7rw INTEGER (1 .. 7) .compaq-common-mgmt.1.8.10 |
agentDSTRepeatingEndHourthe hour of the DST Repeating End Day of Weekrw INTEGER (0 .. 23) .compaq-common-mgmt.1.8.11 |
agentDSTRepeatingEndMinutethe minute of the DST Repeating End Hourrw INTEGER (0 .. 59) .compaq-common-mgmt.1.8.12 |
agentDSTAnnualStartMonththe annual start month (January = 1, .., Decenber = 12)rw INTEGER (1 .. 12) .compaq-common-mgmt.1.8.13 |
agentDSTAnnualStartDayOfMonththe day of annual start monthrw INTEGER (1 .. 31) .compaq-common-mgmt.1.8.14 |
agentDSTAnnualStartHourthe hour of the annual start dayrw INTEGER (0 .. 23) .compaq-common-mgmt.1.8.15 |
agentDSTAnnualStartMinutethe minute of the annual start hourrw INTEGER (0 .. 59) .compaq-common-mgmt.1.8.16 |
agentDSTAnnualEndMonththe annual end month (January = 1, .., Decenber = 12)rw INTEGER (1 .. 12) .compaq-common-mgmt.1.8.17 |
agentDSTAnnualEndDayOfMonththe day of annual end monthrw INTEGER (1 .. 31) .compaq-common-mgmt.1.8.18 |
agentDSTAnnualEndHourthe hour of annual end day of monthrw INTEGER (0 .. 23) .compaq-common-mgmt.1.8.19 |
agentDSTAnnualEndMinutethe minute of annual end hourrw INTEGER (0 .. 59) .compaq-common-mgmt.1.8.20 |
agentSwitchCommonMgmt OBJECT IDENTIFIER .compaq-common-mgmt.3 |
agentSwitchCube OBJECT IDENTIFIER .compaq-common-mgmt.3.1 |
agentSwitchCubeTableA table of cube information. SEQUENCE OF AgentSwitchCubeEntry .compaq-common-mgmt.3.1.1 |
agentSwitchCubeEntryA switch cube description. AgentSwitchCubeEntry .compaq-common-mgmt.3.1.1.1 |
agentSwitchCubeTypeThis specifies the type of this instance of cube.
This value will be one of the following:
other(1)
Cube type could not be determined.
dualTSX(2)
Switch Dual Base-T plus Dual LC Fiber Interconnect Module.
quadT(3)
Switch Quad Base-T Copper Interconnect Module.ro Enumeration .compaq-common-mgmt.3.1.1.1.1 |
agentSwitchCubeSpareNameThe name of the cube.
The string will be empty if the cube does not report the
name or it could not be determined.ro DisplayString .compaq-common-mgmt.3.1.1.1.2 |
agentSwitchCubeSparePartNumberThe spare part number of the cube.
The string will be empty if the enclosure does not report this
function.ro DisplayString .compaq-common-mgmt.3.1.1.1.3 |
agentSwitchPowerSupply OBJECT IDENTIFIER .compaq-common-mgmt.3.2 |
agentSwitchPowerSupplyTableA table of power supply information. SEQUENCE OF AgentSwitchPowerSupplyEntry .compaq-common-mgmt.3.2.1 |
agentSwitchPowerSupplyEntryA switch power supply description. AgentSwitchPowerSupplyEntry .compaq-common-mgmt.3.2.1.1 |
agentSwitchPowerSupplyIndexA number that uniquely specifies this power supply in the enclosure.ro INTEGER .compaq-common-mgmt.3.2.1.1.1 |
agentSwitchPowerSupplyMaxPwrOutputThe maximum power output of the power supply in watts.
The value will be -1 if the power supply does not report the
value.ro INTEGER .compaq-common-mgmt.3.2.1.1.2 |
agentSwitchPowerSupplyCurPwrOutputThe current power output of the power supply in watts.
The value will be -1 if the power supply does not report the
value.ro INTEGER .compaq-common-mgmt.3.2.1.1.3 |
agentSwitchPowerSupplyIntakeTempThe current air temperature at the intake of the power supply
in degrees celsius.
The value will be -1 if the power supply does not report the
value.ro INTEGER .compaq-common-mgmt.3.2.1.1.4 |
agentSwitchPowerSupplyExhaustTempThe current air temperature at the exhaust of the power supply
in degrees celsius.
The value will be -1 if the power supply does not report the
value.ro INTEGER .compaq-common-mgmt.3.2.1.1.5 |
agentSwitchPowerSupplyStatusThe status of the power supply.ro Enumeration .compaq-common-mgmt.3.2.1.1.6 |
agentSwitchPowerSupplyInputLineStatusThe status of line input power.ro Enumeration .compaq-common-mgmt.3.2.1.1.7 |
agentSwitchPowerSupplyConditionThe condition of the power supply.
This value will be one of the following:
other(1)
The status could not be determined or not present.
ok(2)
The power supply is operating normally.
degraded(3)
A temperature sensor, fan or other power supply component is
outside of normal operating range.
failed(4)
A power supply component detects a condition that could
possibly damage the system.ro Enumeration .compaq-common-mgmt.3.2.1.1.8 |
agentSwitchFan OBJECT IDENTIFIER .compaq-common-mgmt.3.3 |
agentSwitchFanTableA table of fan information. SEQUENCE OF AgentSwitchFanEntry .compaq-common-mgmt.3.3.1 |
agentSwitchFanEntryA switch fan description. AgentSwitchFanEntry .compaq-common-mgmt.3.3.1.1 |
agentSwitchFanIndexA number that uniquely specifies this fan within this server
enclosure in the rack.ro INTEGER .compaq-common-mgmt.3.3.1.1.1 |
agentSwitchFanConditionThe condition of the fan.
This value will be one of the following:
other(1)
Fan status detection is not supported.
ok(2)
The fan is operating properly.
degraded(3)
A redundant fan is not operating properly.
failed(4)
A non-redundant fan is not operating properly.ro Enumeration .compaq-common-mgmt.3.3.1.1.2 |
agentSwitchTempSensor OBJECT IDENTIFIER .compaq-common-mgmt.3.4 |
agentSwitchTempSensorTableA table of temperature sensor information. SEQUENCE OF AgentSwitchTempSensorEntry .compaq-common-mgmt.3.4.1 |
agentSwitchTempSensorEntryA switch temperature sensor description. AgentSwitchTempSensorEntry .compaq-common-mgmt.3.4.1.1 |
agentSwitchTempSensorIndexA number that uniquely specifies this temperature sensor within
this server enclosure in the rack.ro INTEGER .compaq-common-mgmt.3.4.1.1.1 |
agentSwitchTempSensorCurrentThis is the current temperature sensor reading in degrees
celsius.
If this value cannot be determined by software, then a value
of -1 will be returned.ro INTEGER .compaq-common-mgmt.3.4.1.1.2 |
agentSwitchTempSensorThresholdThis is the threshold temperature sensor setting
in degrees celsius. This is the temperature in which the
sensor will be considered to be in a tripped state this
causing some action to occur depending on the type of
the sensor. The action of temperature sensor threshold
will be indicated by the cpqRackCommonEnclosureTempType
item. If the type is blowout(5), then the temperature sensor
will cause the fans to speed up. If the type is caution(9),
then the temperature sensor is in a degraded state. If the
type is critical(15), then the server will be considered
as in a failed state.
If this value cannot be determined by software, then a value
of -1 will be returned.ro INTEGER .compaq-common-mgmt.3.4.1.1.3 |
agentSwitchTempSensorConditionThe Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within the normal operating range.
degraded(3)
The temperature sensor is outside of the normal operating range.
failed(4)
The temperature sensor detects a condition that could
possibly damage the system.
The system will automatically shutdown if the failed(4) condition
results, so it is unlikely that this value will ever be returned
by the agent.ro Enumeration .compaq-common-mgmt.3.4.1.1.4 |
agentSwitchTempSensorTempTypeThis specifies the type of this instance of temperature
sensor.
This value will be one of the following:
other(1)
Temperature threshold type could not be determined.
blowout(5)
If a blowout(5) temperature sensor reaches its threshold,
the fan or fans in the area of the temperature sensor will
increase in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
caution(9)
If a caution(9) temperature sensor reaches its threshold, the
cpqRackCommonEnclosureTempCondition will be set to degraded(3)
and the system will either continue or shutdown depending
on the user preferences.
critical(15)
If a critical(15) temperature sensor reaches its threshold,
the cpqHeTemperatureCondition will be set to failed(4)
and the system will shutdown.ro Enumeration .compaq-common-mgmt.3.4.1.1.5 |
endOfMIBEnd of MIBro INTEGER .compaq-common-mgmt.3.9999 |