Home/Catalog/CISCO-FASTHUB-MIB

CISCO-FASTHUB-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for CISCO-FASTHUB-MIB.

15
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

15 total
Object Name
ciscoFastHubMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.12124.4.11
RFC-1215
Unknown
.1.3.6.1.4.1.12124.4.11
ciscoFastHubMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.12124.4.11.1
mrStack
OBJECT IDENTIFIER
.1.3.6.1.4.1.12124.4.11.1.1
mrStackUnitCapacityThis object returns the maximum number of repeater units that can be stacked in the system and managed as one repeater.ro
INTEGER
.1.3.6.1.4.1.12124.4.11.1.1.1
mrStackNumberOfUnitsPresentThis object returns the current number of repeater units in the stack.ro
INTEGER
.1.3.6.1.4.1.12124.4.11.1.1.2
mrStackSelectPrimarySupervisorUnitIn a multi-unit FastHub stack with more than one Supervisor management module installed, this object selects which unit and hence, which Supervisor module, should have the primary management role. The value specified is a unit number that corresponds to an integer index into the mrStackUnitTable. Once a primary management unit has been chosen, the remaining management modules, if any, will automatically assume the standby role.rw
INTEGER
.1.3.6.1.4.1.12124.4.11.1.1.3
mrStackPOSTSelectnormal(1), abbreviated(2) This object configures the type of Supervisor Power On Self Test FastHub will run upon power up. The normal(1) setting runs the lengthy and complete version of the self test. The abbreviated(2) setting shortens some of the RAM tests to reduce the start up time.rw
Enumeration
.1.3.6.1.4.1.12124.4.11.1.1.4
mrStackResetreset(1) noReset(2), A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters are retained and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastHub will always return noReset(2) when this object is read.rw
Enumeration
.1.3.6.1.4.1.12124.4.11.1.1.5
mrStackDefaultResetreset(1) noReset(2), A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters revert to their default factory settings, and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastHub will always return noReset(2) when this object is read.rw
Enumeration
.1.3.6.1.4.1.12124.4.11.1.1.6
mrStackClearStatisticsclear(1) noClear(2), A write to this object with noClear(2) results in no action. A write of clear(1) will cause FastHub to reset all repeater statistics to zero. FastHub will also update the object rptrGroupLastOperStatusChange for all applicable repeater groups. This object always returns noClear(2) when read.rwobsolete
Enumeration
.1.3.6.1.4.1.12124.4.11.1.1.7
mrSupervisorLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.12124.4.11.1.2
mrStackUnit
OBJECT IDENTIFIER
.1.3.6.1.4.1.12124.4.11.1.3
mrNetMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.12124.4.11.1.4
mrUpgrade
OBJECT IDENTIFIER
.1.3.6.1.4.1.12124.4.11.1.5