CISCO-FASTHUB-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for CISCO-FASTHUB-MIB.
15
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
15 total| Object Name |
|---|
ciscoFastHubMIB OBJECT IDENTIFIER .1.3.6.1.4.1.12124.4.11 |
RFC-1215 Unknown .1.3.6.1.4.1.12124.4.11 |
ciscoFastHubMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.12124.4.11.1 |
mrStack OBJECT IDENTIFIER .1.3.6.1.4.1.12124.4.11.1.1 |
mrStackUnitCapacityThis object returns the maximum number of repeater units
that can be stacked in the system and managed as one
repeater.ro INTEGER .1.3.6.1.4.1.12124.4.11.1.1.1 |
mrStackNumberOfUnitsPresentThis object returns the current number of repeater units
in the stack.ro INTEGER .1.3.6.1.4.1.12124.4.11.1.1.2 |
mrStackSelectPrimarySupervisorUnitIn a multi-unit FastHub stack with more than one Supervisor
management module installed, this object selects which
unit and hence, which Supervisor module, should have the
primary management role. The value specified is a unit
number that corresponds to an integer index into the
mrStackUnitTable.
Once a primary management unit has been chosen, the
remaining management modules, if any, will automatically
assume the standby role.rw INTEGER .1.3.6.1.4.1.12124.4.11.1.1.3 |
mrStackPOSTSelectnormal(1),
abbreviated(2)
This object configures the type of Supervisor Power On
Self Test FastHub will run upon power up. The normal(1)
setting runs the lengthy and complete version of the
self test. The abbreviated(2) setting shortens some of
the RAM tests to reduce the start up time.rw Enumeration .1.3.6.1.4.1.12124.4.11.1.1.4 |
mrStackResetreset(1)
noReset(2),
A write to this object with reset(1) causes a complete
reset of the repeater hardware and the Supervisor but
does not run the POST. All FastHub configuration
parameters are retained and all network related statistics
in the system are cleared. Setting this object to
noReset(2) has no effect. FastHub will always return
noReset(2) when this object is read.rw Enumeration .1.3.6.1.4.1.12124.4.11.1.1.5 |
mrStackDefaultResetreset(1)
noReset(2),
A write to this object with reset(1) causes a complete
reset of the repeater hardware and the Supervisor but does
not run the POST. All FastHub configuration parameters
revert to their default factory settings, and all network
related statistics in the system are cleared. Setting this
object to noReset(2) has no effect. FastHub will always
return noReset(2) when this object is read.rw Enumeration .1.3.6.1.4.1.12124.4.11.1.1.6 |
mrStackClearStatisticsclear(1)
noClear(2),
A write to this object with noClear(2) results in no
action. A write of clear(1) will cause FastHub to reset
all repeater statistics to zero. FastHub will also update
the object rptrGroupLastOperStatusChange for all applicable
repeater groups.
This object always returns noClear(2) when read.rwobsolete Enumeration .1.3.6.1.4.1.12124.4.11.1.1.7 |
mrSupervisorLog OBJECT IDENTIFIER .1.3.6.1.4.1.12124.4.11.1.2 |
mrStackUnit OBJECT IDENTIFIER .1.3.6.1.4.1.12124.4.11.1.3 |
mrNetMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.12124.4.11.1.4 |
mrUpgrade OBJECT IDENTIFIER .1.3.6.1.4.1.12124.4.11.1.5 |