AI MIB Summary

The CCTEXT-MIB provides management access to ArrowPoint Communications circuit-specific attributes, enabling monitoring of circuit status, configuration parameters, and operational state data for ArrowPoint load balancers and application delivery controllers.

The MIB module used to describe the ArrowPoint Communications Circuit information
Main OID:
apCctExtMib.1.3.6.1.4.1.2467.1.29.1
15
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

15 total
Object Name
apCctExtMib
MODULE-IDENTITY
.1.3.6.1.4.1.2467.1.29.1
apCctTable
SEQUENCE OF APCctEntry
.1.3.6.1.4.1.2467.1.29.2
apCctEntry
APCctEntry
.1.3.6.1.4.1.2467.1.29.2.1
apCctIfIndexro
Integer32
.1.3.6.1.4.1.2467.1.29.2.1.1
apCctNamero
DisplayString
.1.3.6.1.4.1.2467.1.29.2.1.2
apCctDescriptionrw
DisplayString
.1.3.6.1.4.1.2467.1.29.2.1.3
apCctIfTypero
Enumeration
.1.3.6.1.4.1.2467.1.29.2.1.4
apCctStatero
Enumeration
.1.3.6.1.4.1.2467.1.29.2.1.5
apCctLinkCountro
Integer32
.1.3.6.1.4.1.2467.1.29.2.1.6
apCctAclIndexrw
Integer32
.1.3.6.1.4.1.2467.1.29.2.1.7
apCctL2Redundancyrw
Enumeration
.1.3.6.1.4.1.2467.1.29.2.1.8
apCctIrdpUseLimitedBcastrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2467.1.29.2.1.9
apCctIrdpMaxIntervalrw
INTEGER
.1.3.6.1.4.1.2467.1.29.2.1.10
apCctIrdpMinIntervalrw
INTEGER
.1.3.6.1.4.1.2467.1.29.2.1.11
apCctIrdpLifetimerw
INTEGER
.1.3.6.1.4.1.2467.1.29.2.1.12

CCTEXT-MIB Technical Reference Overview

The CCTEXT-MIB SNMP MIB module published by ArrowPoint defines 15 managed OID objects, including 12 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.2467.1.29.1. Key tabular structures include apCctTable.

Key OID Definitions in CCTEXT-MIB

apCctExtMibMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.2467.1.29.1

The MIB module used to describe the ArrowPoint Communications Circuit information

apCctTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2467.1.29.2

A list of information for the specified circuit.

apCctAclIndexInteger32(0..100)read-write
.1.3.6.1.4.1.2467.1.29.2.1.7

The ACL which is currently in use on the circuit.

apCctDescriptionDisplayStringread-write
.1.3.6.1.4.1.2467.1.29.2.1.3

The user defined description string associated with the circuit

apCctEntryAPCctEntrynot-accessible
.1.3.6.1.4.1.2467.1.29.2.1

A group of information to uniquely identify a circuit.

apCctIfIndexInteger32read-only
.1.3.6.1.4.1.2467.1.29.2.1.1

The unique if Index assigned to this circuit.

apCctIfTypeINTEGERread-only
.1.3.6.1.4.1.2467.1.29.2.1.4

The interface type of this circuit.

apCctIrdpLifetimeINTEGER(0..9000)read-write
.1.3.6.1.4.1.2467.1.29.2.1.12

Value placed in the lifetime field of a router advertisement. Default (0) means use 3 times the max. If non-zero, this value must be greater than apCctIrdpMax.

apCctIrdpMaxIntervalINTEGER(4..1800)read-write
.1.3.6.1.4.1.2467.1.29.2.1.10

Maximum interval between advertisements (seconds). Default is 600 seconds.

apCctIrdpMinIntervalINTEGER(0..1800)read-write
.1.3.6.1.4.1.2467.1.29.2.1.11

Minimum interval between advertisements (seconds). Default (0) means use 0.75 times max. If non-zero, this value must be less than apCctIrdpMax.

apCctIrdpUseLimitedBcastTruthValueread-write
.1.3.6.1.4.1.2467.1.29.2.1.9

Enable/disable the use of the limited broadcast address 255.255.255.255 for the transmission of router discovery packets. Default is false (use multicast address 224.0.0.1). This parameter has no meaning if the link does not support multicast (255.255.255.255 will be used).

apCctL2RedundancyINTEGERread-write
.1.3.6.1.4.1.2467.1.29.2.1.8

If enabled, this switch is configured to provide redundancy for this circuit with another switch. Only the active switch will actually receive and forward traffic; the second will be a hot backup.

apCctLinkCountInteger32read-only
.1.3.6.1.4.1.2467.1.29.2.1.6

The number of logical links configured on this circuit.

apCctNameDisplayStringread-only
.1.3.6.1.4.1.2467.1.29.2.1.2

The name of the circuit auto-generated by Circuit manager.

apCctStateINTEGERread-only
.1.3.6.1.4.1.2467.1.29.2.1.5

The state of the circuit. Circuit is active if it has one or more active ports associated with it.

More MIBs from ArrowPoint

Browse all ArrowPointMIBs →
FLOWMGREXT-MIB

SNMP MIB module

289 objects→
CNTEXT-MIB

SNMP MIB module

86 objects→
APENT-MIB

The APENT-MIB provides management definitions for ArrowPoint Communications enterprise devices, specifically monitoring session states, connection counts, and performance metrics for their application delivery controllers and load balancers. It enables the collection of operational data regarding active user sessions, server health, and traffic distribution statistics for network visibility and troubleshooting.

80 objects→
AP64STATS-MIB

The AP64STATS-MIB module provides 64-bit statistical aggregation for RMON, MIB-II, and EtherErrors on Aruba (formerly ProCurve) network switches, enabling precise monitoring of high-volume traffic counters and interface error rates beyond standard 32-bit limitations.

63 objects→
SVCEXT-MIB

The SVCEXT-MIB provides management access to the ArrowPoint Communications content services table, enabling monitoring of content switching states, server pool configurations, and traffic distribution metrics for legacy ArrowPoint Content Switch appliances.

57 objects→
CHASSISMGREXT-MIB

The CHASSISMGREXT-MIB provides management access to ArrowPoint Communications chassis hardware, specifically enabling monitoring of High Speed Serial Interface (HSSI) module status and performance counters. This module facilitates the tracking of interface operational states, error statistics, and physical layer metrics for HSSI ports within the ArrowPoint enterprise environment.

51 objects→