Home/Catalog/BTI-7000-MIB

BTI-7000-MIB

The external MIB definitions for the BTI 7000 series products.
Main OID:
bti7000Mib.1.3.6.1.4.1.18070.1.3
4153
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

4153 total
Object Name
bti7000MibThe external MIB definitions for the BTI 7000 series products.
MODULE-IDENTITY
.1.3.6.1.4.1.18070.1.3
objects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1
networkElement
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.1
neSWVersionThe software version that is active on the NE currently.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.1.1
neNumThis is a unique network element number used to identify the network element and to differentiate it from other NEs in the management domain.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.1.2
neSiteNumThis is a network element site number used to uniquely identify the site of the NE and to differentiate it from other NE sites in the management domain.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.1.3
neDateAndTimeThe current system date and time, without time zone information.rw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.1.4
neTimeZoneThe time zone in which the local time of this system is to be reported. Typically, the time zone is the one in which the system is physically located.rw
TimeZone
.1.3.6.1.4.1.18070.2.2.1.1.5
neAutoDSTA setting that indicates whether the system time should be updated automatically in accordance with the daylight savings time characteristics of the current time zone.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.1.6
neGatewayThe default IP routing gateway for network management interfaces on the node. If not specified, this object returns a value of 0.0.0.0.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.1.7
neSecGatewayThe secondary IP routing gateway for network management interfaces on the node. If not specified, this object returns a value of 0.0.0.0.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.1.8
neActiveGatewayThe IP routing gateway that is currently active on the node. If no gateway is active, this object returns a value of 0.0.0.0.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.1.9
neAutoProvA setting that specifies if automatic provisioning of equipment and facilities is enabled. If automatic provisioning is enabled, this object indicates the default administration status. The possible values include: - enabled: Applicable entities are auto provisioned with the initial state enabled. - disabled: Applicable entities are auto provisioned with the initial state disabled. - autoEnabled: Applicable entities are auto provisioned and placed into the auto-enabled state. - autoProvOff: Auto provisioning is disabled.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.1.10
neAutoDeProvThe time delay after a physical shelf or circuit pack is removed from the NE before the provisioned entities that are supported by the removed equipment are automatically deprovisioned. If this object is set to a value of 000-00, auto deprovisioning is disabled.rwobsolete
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.1.11
neAutoEnabledTimerThe system wide default auto-enable timer value. This timer specifies a time delay after a provisioned facility in the auto-enabled state is cleared of all alarms before the state of the facility transitions to enabled. The default value can be overridden by a facility-specific value that is specified when the facility is either provisioned or edited in its respective table.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.1.12
ntpClient
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.1.13
ntpClientPollingRateThe polling rate for the NTP client to periodically fetch the system time from the list of NTP servers configured.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.1.13.1
ntpClientAuthKeyThe NTP authentication key ID, if authentication is required.rwobsolete
INTEGER
.1.3.6.1.4.1.18070.2.2.1.1.13.2
ntpClientSyncStateStatus indicating if the node is in sync with one of the time servers. Either Y or N.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.1.13.3
ntpClientStratumSpecifies the stratum of the timer server the node in in sync with.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.1.13.4
ntpClientRefIPAddrThe IP address of the time server the node is in sync with.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.1.13.5
ntpClientAssocTableA list of NTP servers to poll for the system time. The NTP client then decides which is best clock source.
SEQUENCE OF NTPClientAssocEntry
.1.3.6.1.4.1.18070.2.2.1.1.13.6
ntpClientAssocEntryThe list entry for an NTP server.
NTPClientAssocEntry
.1.3.6.1.4.1.18070.2.2.1.1.13.6.1
ntpClientAssocIdxThe IP address of the NTP server.
IpAddress
.1.3.6.1.4.1.18070.2.2.1.1.13.6.1.1
ntpClientAssocRowStatusUsed to control the addition and deletion of entries in the NTP client association table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.1.13.6.1.100
ntpOldTimeAndDateThe date and time of the system before the NTP client updated the system clock.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.1.13.7
ntpNewTimeAndDateThe new system date and time updated by the NTP client.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.1.13.8
ntpRefIPThis the NTP server being used as the clock reference for the system.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.1.13.9
ntpRefStratumThis is the stratum of the NTP server being used as the clock reference for the system.ro
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.1.13.10
neFPDetectA setting that indicates whether the system should report pack missing alarms.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.1.14
neHTAutoShutdownA system wide setting that specifies whether the circuit pack pack high temperature automatic shutdown (HTAS) is enabled. When enabled, the circuit packs which support the HTAS feature will be automatically powered down if the shutdown temperature threshold for that circuit pack is exceeded. There will be alarms indicating that the shutdown has occurred. The default setting is enabled.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.1.15
inventory
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.2
shelfInvTableThis table contains one row for every physically detected shelf on the NE. Each row contains a list of attributes that pertain to a physical shelf.
SEQUENCE OF ShelfInvEntry
.1.3.6.1.4.1.18070.2.2.1.2.1
shelfInvEntryThe conceptual row object of the shelf inventory table.
ShelfInvEntry
.1.3.6.1.4.1.18070.2.2.1.2.1.1
shelfInvIdxThe number of the shelf. It is set to 1 for the main shelf, otherwise the object is based on the expansion shelf port on which the shelf is detected, and the number of hops from the main shelf.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.2.1.1.1
shelfInvExpectedNENameThe NE name expected by the main shelf to be reported by the expansion shelf as the name of the NE to which it belongs.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.2
shelfInvExpectedIPAddressThe string representation of the NE NMS IP address that is expected by the main shelf to be reported by the expansion shelf as the IP address of the NE to which it belongs.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.3
shelfInvExpectedShelfNumThe number of the expansion shelf that is expected by the main shelf to be reported by the attached shelf.ro
INTEGER (11|21|31)
.1.3.6.1.4.1.18070.2.2.1.2.1.1.4
shelfInvExpectedMSISerialNumThe serial number of the Main Shelf Interface circuit pack that is expected by the main shelf to be reported by the expansion shelf as the MSI serial number of the NE main shelf to which it belongs.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.5
shelfInvDiscoveredNENameThe actual NE name reported by the expansion shelf as the name of the NE to which it belongs.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.6
shelfInvDiscoveredIPAddressThe string representation of the actual NE NMS IP address reported by the expansion shelf as the IP address of the NE to which it belongs.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.7
shelfInvDiscoveredShelfNumThe actual number of the expansion shelf reported by the attached shelf.ro
INTEGER (11|21|31)
.1.3.6.1.4.1.18070.2.2.1.2.1.1.8
shelfInvDiscoveredMSISerialNumThe actual serial number of the Main Shelf Interface circuit pack reported by the expansion shelf as the MSI serial number of the NE main shelf to which it belongs.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.9
shelfInvTypeIndicates if the shelf functions as a main shelf or an expansion shelf.ro
ShelfType
.1.3.6.1.4.1.18070.2.2.1.2.1.1.10
shelfInvShortNameA concise representation of the shelf brand name.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.11
shelfInvNameThe full representation of the shelf brand name.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.12
shelfInvChassisPECA string representation of the Product Equipment Code for the shelf chassis alone.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.13
shelfInvChassisCLEIA string representation of the Telcordia Common Language Equipment Identifier for the shelf chassis alone.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.14
shelfInvAssemblyPECA string representation of the Product Equipment Code for the shelf assembly, which bundles the shelf chassis, shelf interface pack, and cooling unit.roobsolete
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.15
shelfInvRevThe shelf hardware revision number. A value of 0 indicates that the revision is unspecified.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.1.1.16
shelfInvConfigThe shelf configuration with respect to the number of slots for holding replaceable circuit packs. Note: This object is no longer supported as of BTI 7000 Release 8.1.0, and is maintained in the MIB for backwards- compatibility for management of pre-8.1 nodes.rodeprecated
ShelfConfigType
.1.3.6.1.4.1.18070.2.2.1.2.1.1.17
shelfInvUSIThe Unique Serial Identifier (only for FNC-branded equipment)ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.18
shelfInvSerialNumThe serial number of the unit.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.19
shelfInvMfgDateThe shelf manufacture date in the format YYYY-MM-DD.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.20
shelfInvMfgLocThe shelf manufacture location.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.21
shelfInvTestDateThe shelf test date in the format YYYY-MM-DD.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.22
shelfInvTestLocThe shelf test location.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.1.1.23
slotInvTableThis table contains one row for every slot on every shelf of the NE in which a circuit pack or other replaceable unit is seated. Each row contains a list of attributes that pertain to the circuit pack within the slot.
SEQUENCE OF SlotInvEntry
.1.3.6.1.4.1.18070.2.2.1.2.2
slotInvEntryThe conceptual row object of the slot inventory table.
SlotInvEntry
.1.3.6.1.4.1.18070.2.2.1.2.2.1
slotInvShelfIdxThe number of the shelf on which the slot inventory item is detected.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.2.2.1.1
slotInvSlotTypeIdxThe type of slot that contains the inventory item.ro
SlotType
.1.3.6.1.4.1.18070.2.2.1.2.2.1.2
slotInvSlotIdxThe number of the slot within the shelf containing the inventory item. The number is from 1 to 20 for regular circuit pack slots. For main shelf interface type slots, the number is set to 0. For 7060/7030/7020 expansion shelf interface and cooling unit type slots, the number is set to 0. For 7200 common communications module type slots, the number is 1 or 2. For 7200 cooling unit type slots, the number is from 1 to 4.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.2.1.3
slotInvSWVersionThe version of the software running on the circuit pack in the given slot.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.4
slotInvPackShortNameA concise representation of the name of the circuit pack or unit.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.5
slotInvPackNameThe full name of the circuit pack or unit.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.6
slotInvPackPECThe Product Equipment Code for the circuit pack or unit.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.7
slotInvPackCLEIThe Telcordia Common Language Equipment Identifier for the circuit pack or unit.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.8
slotInvPackSerialNumThe serial number of the unit.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.9
slotInvPackRevThe circuit pack or unit hardware revision number. A value of 0 indicates that the revision is unspecified.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.2.1.10
slotInvPackMfgDateThe circuit pack manufacture date in the format YYYY-MM-DD.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.11
slotInvPackMfgLocThe circuit pack manufacture location.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.12
slotInvPackTestDateThe circuit pack test date in the format YYYY-MM-DD.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.13
slotInvPackTestLocThe circuit pack test location.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.14
slotInvUpgradeStageThe stage of the circuit pack upgrade process that has been completed.ro
UpgradeCompleteStage
.1.3.6.1.4.1.18070.2.2.1.2.2.1.15
slotInvUpgradeResultIndicates if the identified stage of the circuit pack upgrade process has resulted in success or failure.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.2.2.1.16
slotInvPackUSIThe Unique Serial Identifier (only for FNC-branded equipment)ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.2.1.17
slotInvTempHighThThe circuit pack high temperature threshold.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.2.1.18
slotInvTempShutdownThThe circuit pack shutdown temperature threshold.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.2.1.19
pluggableInvTableThis table contains one row for every SFP/XFP or other pluggable present on any circuit pack or other replaceable unit present in the NE. Each row contains a list of attributes that pertain to the detected SFP/XFP.
SEQUENCE OF PluggableInvEntry
.1.3.6.1.4.1.18070.2.2.1.2.3
pluggableInvEntryThe conceptual row object of the pluggable inventory table.
PluggableInvEntry
.1.3.6.1.4.1.18070.2.2.1.2.3.1
pluggableInvShelfIdxThe number of the shelf on which the pluggable inventory item resides.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.2.3.1.1
pluggableInvSlotTypeIdxThe type of slot containing the pluggable inventory item.ro
SlotType
.1.3.6.1.4.1.18070.2.2.1.2.3.1.2
pluggableInvSlotIdxThe number of the slot that contains the pluggable inventory item.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.3.1.3
pluggableInvPortIdxThe number of the port on the circuit pack that contains the pluggable inventory item.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.3.1.4
pluggableInvTypeThe type of small form-factor pluggable inventory item.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.2.3.1.5
pluggableInvPECThe Product Equipment Code for the pluggable inventory item.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.6
pluggableInvCLEIThe Telcordia Common Language Equipment Identifier for the pluggable inventory item.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.7
pluggableInvVendorNameThe Vendor Name of the pluggable inventory item.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.8
pluggableInvVendorOUIThe Vendor IEEE Organizationally Unique Identifier.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.9
pluggableInvVendorPartNumThe Vendor Part Number.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.10
pluggableInvVendorRevThe Vendor Revision Number.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.11
pluggableInvVendorSerialNumThe Vendor Serial Number.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.12
pluggableInvMfgDateThe manufacture date in the format YYYY-MM-DD..ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.13
pluggableInvConnectorTypeThe type of connector on the pluggable unit.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.2.3.1.14
pluggableInvMinBitRateThe minimum bit rate supported by the pluggable. A value of 0 means unspecified.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.3.1.15
pluggableInvMaxBitRateThe maximum bit rate supported by the pluggable. A value of 0 means unspecified.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.3.1.16
pluggableInvNomBitRateThe nominal bit rate supported by the pluggable. A value of 0 means unspecified.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.3.1.17
pluggableInvEncodingA textual comma-delimited list of serial encoding mechanisms supported by the pluggable.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.18
pluggableInvWavelengthThe wavelength transmitted by the pluggable. A value of 0 means unspecified.ro
FixedX100 UNITS "nanometers/100"
.1.3.6.1.4.1.18070.2.2.1.2.3.1.19
pluggableInvReachThe reach supported by the pluggable. A value of 0 means unspecified.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.3.1.20
pluggableInvTxFaultImplIndicates if the pluggable implements the Transmit Fault signal.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.2.3.1.21
pluggableInvLOSImplIndicates if the pluggable implements the Loss of Signal signal.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.2.3.1.22
pluggableInvDDiagImplIndicates if the pluggable implements support for Digital Diagnostics.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.2.3.1.23
pluggableInvTxDisableImplIndicates if the pluggable implements support for disabling the transmit laser.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.2.3.1.24
pluggableInvMediaThe physical media type of the pluggablero
Enumeration
.1.3.6.1.4.1.18070.2.2.1.2.3.1.25
pluggableInvUSIThe Unique Serial Identifier (only for FNC-branded equipment)ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.2.3.1.26
pluggableInvWavelengthMinThe wavelength minimum for the tunable pluggable. A value of 0 means unspecified.ro
FixedX100 UNITS "nanometers/100"
.1.3.6.1.4.1.18070.2.2.1.2.3.1.27
pluggableInvWavelengthMaxThe wavelength maximum for the tunable pluggable.A value of 0 means unspecified.ro
FixedX100 UNITS "nanometers/100"
.1.3.6.1.4.1.18070.2.2.1.2.3.1.28
pluggableInvWavelengthSpacingThe wavelength spacing for the tunable pluggable. A value of 0 means unspecified.ro
INTEGER ( 0 | 50 | 100 ) UNITS "GHz"
.1.3.6.1.4.1.18070.2.2.1.2.3.1.29
slotInvDataTableThis table contains a listing of any specialized data records available for the slot inventory entries on the system. Each row contains a single item of data for a specialized data record for a slot inventory entry.
SEQUENCE OF SlotInvDataEntry
.1.3.6.1.4.1.18070.2.2.1.2.4
slotInvDataEntryThe conceptual row object of the slot inventory data table.
SlotInvDataEntry
.1.3.6.1.4.1.18070.2.2.1.2.4.1
slotInvDataShelfIdxThe number of the shelf on which the slot inventory item is detected.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.2.4.1.1
slotInvDataSlotTypeIdxThe type of slot that contains the inventory item.
SlotType
.1.3.6.1.4.1.18070.2.2.1.2.4.1.2
slotInvDataSlotIdxThe number of the slot within the shelf containing the inventory item. The number is from 1 to 20 for regular circuit pack slots. For shelfInterface and coolingUnit type slots, the number is set to 0.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.2.4.1.3
slotInvDataRecordIdxThe specialized data record index.
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.2.4.1.4
slotInvDataNameIdxThe name of the data item.
Enumeration
.1.3.6.1.4.1.18070.2.2.1.2.4.1.5
slotInvDataValueThe value of the data item.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.2.4.1.6
equipment
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.3
shelfTableThis table contains one row for every provisioned shelf on the NE. Each row contains a list of attributes that pertain to a provisioned shelf.
SEQUENCE OF ShelfEntry
.1.3.6.1.4.1.18070.2.2.1.3.1
shelfEntryThe conceptual row object of the shelf table.
ShelfEntry
.1.3.6.1.4.1.18070.2.2.1.3.1.1
shelfIdxThe number of the shelf that has been provisioned. This is set to 1 for the main shelf. Otherwise, the number is based on the expansion shelf port number on which this shelf is expected to be detected and the number of hops from the main shelf.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.3.1.1.1
shelfProvConfigThe provisioned configuration for the shelf. Note: This object is no longer supported as of BTI 7000 Release 8.1.0, and is maintained in the MIB for backwards- compatibility for management of pre-8.1 nodes.rwdeprecated
ShelfConfigType
.1.3.6.1.4.1.18070.2.2.1.3.1.1.2
shelfDiscConfigThe configuration of the actual shelf discovered. Note: This object is no longer supported as of BTI 7000 Release 8.1.0, and is maintained in the MIB for backwards- compatibility for management of pre-8.1 nodes.rodeprecated
ShelfConfigType
.1.3.6.1.4.1.18070.2.2.1.3.1.1.3
shelfTypeIndicates if the provisioned shelf is a main or expansion shelf. Only expansion shelves can be created. The main shelf is automatically provisioned and can never be de-provisioned.rw
ShelfType
.1.3.6.1.4.1.18070.2.2.1.3.1.1.4
shelfPECIndicates the provisioned shelf Product Equipment Code. This is a mandatory object when a row of the shelf table is created. The PEC can only be set at the time of row creation, and it cannot be edited later.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.3.1.1.5
shelfAdminStatusThe administrative status of the shelf.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.3.1.1.6
shelfOperStatusThe reported operational status of the shelf.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.3.1.1.7
shelfOperStatQlfrA textual list of qualifiers of the reported operational status of the shelf.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.3.1.1.8
shelfIdTextual data recorded by the user to describe the provisioned shelf in a manner useful to the user such as the location where the shelf is installed.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.3.1.1.9
shelfCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.1.1.10
shelfCustom2A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.1.1.11
shelfCustom3A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.1.1.12
shelfPowerFeedAThe power feed mode for rail A.rw
PowerFeedModeType
.1.3.6.1.4.1.18070.2.2.1.3.1.1.13
shelfPowerFeedBThe power feed mode for rail B.rw
PowerFeedModeType
.1.3.6.1.4.1.18070.2.2.1.3.1.1.14
shelfRowStatusUsed to control the addition and deletion of entries in the shelf table, which in turn controls provisioning and deprovisioning of shelf objects.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.1.1.100
cpTableThis table contains one row for every provisioned circuit pack on the NE. Each row contains a list of attributes that pertain to a provisioned circuit pack.
SEQUENCE OF CpEntry
.1.3.6.1.4.1.18070.2.2.1.3.2
cpEntryThe conceptual row object of the circuit pack table.
CpEntry
.1.3.6.1.4.1.18070.2.2.1.3.2.1
cpTypeIdxThe specific type of circuit pack provisioned.ro
CpType
.1.3.6.1.4.1.18070.2.2.1.3.2.1.1
cpShelfIdxThe number of the shelf on which the circuit pack is provisioned.ro
INTEGER (0|1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.3.2.1.2
cpSlotIdxThe number of the slot in which the circuit pack is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.3.2.1.3
cpPECIndicates the provisioned circuit pack Product Equipment Code. This is a mandatory object when a row of the circuit pack table is created. The PEC can only be set at the time of row creation, and it cannot be edited later.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.3.2.1.4
cpAdminStatusThe administrative status of the circuit pack.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.3.2.1.5
cpOperStatusThe reported operational status of the circuit pack.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.3.2.1.6
cpOperStatQlfrA textual list of qualifiers of the reported operational status of the circuit pack.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.3.2.1.7
cpIdTextual data recorded by the user to describe the provisioned circuit pack in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.3.2.1.8
cpCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.2.1.9
cpCustom2A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.2.1.10
cpCustom3A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.2.1.11
cpUpgradeStageUsed in notifications sent during the circuit pack software upgrade process. It indicates the stage of the circuit pack upgrade process that has been completed.ro
UpgradeCompleteStage
.1.3.6.1.4.1.18070.2.2.1.3.2.1.12
cpUpgradeResultIndicates if the identified stage of the circuit pack upgrade process has resulted in success or failure.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.3.2.1.13
cpRowStatusUsed to control the addition and deletion of entries in the circuit pack table, which in turn controls the provisioning and de-provisioning of circuit pack objects.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.3.2.1.100
facilities
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.4
oaTableThis table contains one row for every provisioned optical amplifier facility on the NE. Each row contains a list of attributes that pertain to the optical amplifier.
SEQUENCE OF OaEntry
.1.3.6.1.4.1.18070.2.2.1.4.1
oaEntryThe conceptual row object of the optical amplifier table.
OaEntry
.1.3.6.1.4.1.18070.2.2.1.4.1.1
oaTypeIdxThe specific type of optical amplifier provisioned.ro
OaType
.1.3.6.1.4.1.18070.2.2.1.4.1.1.1
oaShelfIdxThe number of the shelf on which the optical amplifier facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.1.1.2
oaSlotIdxThe number of the slot in which the optical amplifier facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.1.1.3
oaIdxThe number of the port on the circuit pack on which the optical amplifier facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.1.1.4
oaCaseTempMaxThThe case temperature threshold.rw
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.5
oaCaseTempMaxShutdownThThe case temperature shutdown threshold.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.6
oaLaserTempMinShutdownThThe laser temperature minimum shutdown threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.7
oaLaserTempMaxShutdownThThe laser temperature maximum shutdown threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.8
oaOpticalPwrReceivedMinThThe optical power received minimum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.rw
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.9
oaOpticalPwrReceivedMaxThThe optical power received maximum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.rw
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.10
oaSSIOpticalPwrReceivedMaxThThe secondary stage input optical power received maximum threshold. This object is applicable only to OLAM type amplifiers.rw
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.11
oaOpticalPwrTransmittedMinThThe optical power transmitted minimum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.rw
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.12
oaOpticalPwrTransmittedMaxThThe optical power transmitted maximum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.rw
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.13
oaBackReflectionSafetyThThe optical back reflection safety threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.14
oaMSInsertionLossMaxThThis is the mid-stage maximum insertion loss signal threshold. It applies to mid-stage access amplifiers only.rw
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.15
oaCaseTempThe optical amplifier case temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.16
oaLaser1TempThe temperature of the optical amplifier laser 1.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.17
oaLaser2TempThe temperature of the optical amplifier laser 2.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.18
oaOpticalPwrReceivedThe optical power received on the input of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.19
oaSSIOpticalPwrReceivedThe optical power received on the second stage of the amplifier. It applies to mid-stage access amplifiers only.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.20
oaOpticalPwrTransmittedThe optical power transmitted at the output of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.21
oaMSInsertionLossThe mid-stage insertion loss. This object is only applicable to OLAM type amplifiers.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.22
oaEffectiveGainThe effective gain level of the optical amplifier.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.33
oaFSOOpticalPwrTransmittedThe optical power transmitted at the output of the first stage of the amplifier. It applies to mid-stage access amplifiers only.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.34
oaLaser1CurrentThe optical amplifier laser 1 current.ro
FixedX10 UNITS "mAmp/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.35
oaLaser2CurrentThe optical amplifier laser 2 current.ro
FixedX10 UNITS "mAmp/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.36
oaLaser1PowerThe optical amplifier laser 1 power.ro
FixedX10 UNITS "mWatts/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.37
oaLaser2PowerThe optical amplifier laser 2 power.ro
FixedX10 UNITS "mWatts/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.38
oaOpticalBackReflectionThe optical back reflection of the amplifier.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.39
oaVariableOpticalAttenuationThe variable optical attenuation of the amplifier.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.40
oaAdminStatusThe administrative status of the optical amplifier.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.1.1.41
oaOperStatusThe reported operational status of the optical amplifier.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.1.1.42
oaOperStatQlfrA textual list of qualifiers of the reported operational status of the optical amplifier.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.1.1.43
oaAutoEnableTimerSpecifies the auto-enable timer for the targeted optical amplifier. This value only applies if the oaAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. The supported range of values is 000-00 to 096-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.1.1.44
oaActAutoEnableTimerIndicates the time remaining on the auto-enable timer, if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.1.1.45
oaModeSettingThe desired mode of operation to which this optical amplifier is set.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.1.1.46
oaGainSettingThe effective gain (excluding ASE) set point. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.rw
FixedX10 UNITS "dB"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.47
oaPwrSettingThe signal output power (excluding ASE) set point. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned.rw
FixedX10 UNITS "dBm"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.48
oaTiltCompSettingThe desired tilt compensation to which this optical amplifier is set.rw
FixedX10 UNITS "dB"
.1.3.6.1.4.1.18070.2.2.1.4.1.1.49
oaStatusThe specific operational status of the amplifier.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.1.1.50
oaLaserStatusThe actual operational status of the optical amplifier laser.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.1.1.51
oaId1Textual data recorded by the user to describe the provisioned optical amplifier in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.1.1.52
oaId2Textual data recorded by the user to describe the provisioned optical amplifier in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.1.1.53
oaFiberTypeAn optional specification of the fiber type that interfaces with the optical amplifier.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.1.1.54
oaGridAn optional indication of the WDM grid to which the link conforms.rw
WDMGrid
.1.3.6.1.4.1.18070.2.2.1.4.1.1.55
oaNumChannelsAn optional indication of the number of channels that the link is carrying.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.1.1.56
oaCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.1.1.57
oaCustom2A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.1.1.58
oaCustom3A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.1.1.59
oaWavelengthThe wavelength transmitted from the OA port. This object applies only to single channel amplifiers (sba, spa).rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.1.1.60
oaRemoteIdIdentifies the remote node and port to which the optical amplifier port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.1.1.61
oaRowStatusUsed to control the addition and deletion of entries in the optical amplifier table, which in turn controls provisioning and deprovisioning of optical amplifier facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.1.1.100
xcvrTableThis table contains one row for every provisioned optical transceiver on a wavelength translator, regenerator or manager card. Each row contains a list of attributes that pertain to the transceiver.
SEQUENCE OF XcvrEntry
.1.3.6.1.4.1.18070.2.2.1.4.2
xcvrEntryThe conceptual row object of the optical transceiver table.
XcvrEntry
.1.3.6.1.4.1.18070.2.2.1.4.2.1
xcvrTypeIdxThe specific type of wavelength conversion function of the circuit pack on which the transceiver is provisioned.ro
XcvrType
.1.3.6.1.4.1.18070.2.2.1.4.2.1.1
xcvrShelfIdxThe number of the shelf on which the transceiver is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.2.1.2
xcvrSlotIdxThe number of the slot within which the transceiver is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.2.1.3
xcvrIdxThe number of the port on the circuit pack on which the transceiver is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.2.1.4
xcvrOpticalPwrReceivedMinThThis is the optical power received minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.2.1.5
xcvrOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.2.1.6
xcvrOpticalPwrTransmittedMinThThis is the optical power transmitted minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.2.1.7
xcvrOpticalPwrTransmittedMaxThThis is the optical power transmitted maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.2.1.8
xcvrOpticalPwrReceivedThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.2.1.9
xcvrOpticalPwrTransmittedThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.2.1.10
xcvrProtSwEvtTypeIndicates the type of protection switching event that has occured on an optical transceiver port.ro
ProtSwEvtType
.1.3.6.1.4.1.18070.2.2.1.4.2.1.11
xcvrPECAn optionally provisioned transceiver Product Equipment Code used to validate the physically present transceiver.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.12
xcvrAdminStatusThe administrative status of the optical transceiver.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.2.1.13
xcvrOperStatusThe reported operational status of the optical transceiver.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.2.1.14
xcvrOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the optical transceiver.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.2.1.15
xcvrAutoEnableTimerSpecifies the auto-enable timer for the targeted optical transceiver. This value only applies if the xcvrAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.2.1.16
xcvrActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.2.1.17
xcvrProtocolThe protocol of the service to be carried by the port. This is a mandatory object when a row of the transceiver table is created.rw
XcvrProtocolType
.1.3.6.1.4.1.18070.2.2.1.4.2.1.18
xcvrWavelengthThe wavelength to be transmitted by the transceiver port. This is a mandatory object when a row of the transceiver table is created for ports that have a pluggable transceiver.rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.2.1.19
xcvrVendorPN1An optionally provisioned part number used to validate the physically present transceiver.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.20
xcvrVendorPN2An optionally provisioned part number used to validate the physically present transceiver.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.21
xcvrVendorPN3An optionally provisioned part number used to validate the physically present transceiver.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.22
xcvrPhyPMMonIndicates if the port is configured to report threshold crossing conditions for physical layer performance monitoring parameters.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.2.1.23
xcvrFPSDIndicates if the port is configured for Fault Propagation Shut Down.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.2.1.24
xcvrLaserStatusAn indication of the operational status of the transceiver laser.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.2.1.25
xcvrId1Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.26
xcvrId2Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.27
xcvrFiberTypeAn optional specification of the fiber type that interfaces to the optical transceiver.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.2.1.28
xcvrGridAn optical indication of the WDM grid the link conforms.rw
WDMGrid
.1.3.6.1.4.1.18070.2.2.1.4.2.1.29
xcvrCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.2.1.30
xcvrCustom2A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.2.1.31
xcvrCustom3A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.2.1.32
xcvrTraceLabelIf specified, this attribute will describe the trace label to be used in the outgoing OTN or SONET/SDH trace.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.33
xcvrExpectedTraceLabelThis attribute will describe the trace label that is expected to be received in the incoming OTN or SONET/SDH trace. If specified, this expected trace label will be compared to the actual value for xcvrReceivedTraceLabel, and a trace mismatch alarm will be raised if the two trace labels do not match.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.34
xcvrReceivedTraceLabelThe actual received trace label on the incoming OTN or SONET/SDH trace.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.2.1.35
xcvrSDBERThThe Bit Error Rate threshold above which the Signal Degrade condition is raised.rw
BERType
.1.3.6.1.4.1.18070.2.2.1.4.2.1.36
xcvrLoopbackTypeThe loopback type that is currently active on the xcvrro
LoopbackType
.1.3.6.1.4.1.18070.2.2.1.4.2.1.37
xcvrRemoteIdIdentifies the remote node and port to which the transceiver port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.2.1.38
xcvrRowStatusUsed to control the addition and deletion of entries in the Transceiver table, which in turn controls provisioning and deprovisioning of optical transceiver facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.2.1.100
amdTableThis table contains one row for every provisioned active multiplexer-demultiplexer facility. AMD facilities include AMD line facilities and AMD channel facilities. Each row contains a list of attributes that pertain to one facility.obsolete
SEQUENCE OF AmdEntry
.1.3.6.1.4.1.18070.2.2.1.4.3
amdEntryThe conceptual row object of the Active Mux-Demux table.obsolete
AmdEntry
.1.3.6.1.4.1.18070.2.2.1.4.3.1
amdTypeIdxThe specific type of active multiplexer-demultiplexer circuit pack on which the facility is provisioned.roobsolete
AmdType
.1.3.6.1.4.1.18070.2.2.1.4.3.1.1
amdShelfIdxThe number of the shelf on which the active multiplexer-demultiplexer facility is provisioned.roobsolete
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.3.1.2
amdSlotIdxThe number of the slot within which the active multiplexer-demultiplexer facility is provisioned.roobsolete
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.4.3.1.3
amdLineIdxThe number of the multiplexed wavelength line on the AMD circuit pack.roobsolete
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.3.1.4
amdPortIdxIdentifies a specific port on the identified line of the AMD circuit pack.roobsolete
AmdPortType
.1.3.6.1.4.1.18070.2.2.1.4.3.1.5
amdOpticalPwrReceivedMinThThis is the optical power received minimum threshold.rwobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.3.1.6
amdOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.rwobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.3.1.7
amdOpticalPwrTransmittedTargetThis is the optical power transmitted target level.rwobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.3.1.8
amdOpticalAttenuationTargetThis is the optical power attenuation target level.rwobsolete
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.4.3.1.9
amdOpticalPwrReceivedThe optical input power received for the channel.roobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.3.1.10
amdOpticalPwrTransmittedThe optical power level transmitted for the channel.roobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.3.1.11
amdOpticalAttentuationThe optical power attenuation for the line.roobsolete
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.4.3.1.12
amdAdminStatusThe administrative status of the AMD port.rwobsolete
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.3.1.13
amdOperStatusThe reported operational status of the AMD port.roobsolete
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.3.1.14
amdOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the AMD port.roobsolete
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.3.1.15
amdAutoEnableTimerSpecifies the auto-enable timer for the targeted AMD port. This value only applies if the amdAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rwobsolete
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.3.1.16
amdActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.roobsolete
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.3.1.17
amdWavelengthThe wavelength transmitted from the AMD port. This object applies only to channel ports.roobsolete
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.3.1.18
amdId1Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user.rwobsolete
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.3.1.19
amdId2Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user.rwobsolete
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.3.1.20
amdFiberTypeAn optional specification of the fiber type that interfaces to the AMD port.rwobsolete
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.3.1.21
amdGridAn optical indication of the WDM grid to which the AMD port link conforms.rwobsolete
WDMGrid
.1.3.6.1.4.1.18070.2.2.1.4.3.1.22
amdCustom1A variable length text string for operating company use.rwobsolete
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.3.1.23
amdCustom2A variable length text string for operating company use.rwobsolete
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.3.1.24
amdCustom3A variable length text string for operating company use.rwobsolete
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.3.1.25
amdRowStatusThe active multiplexer-demultiplexer table RowStatus object is not readable or writeable because all entries in the AMD table are automatically created and deleted when the AMD circuit pack is created or deleted. This AMD row status object is used only in database change notifications to indicate if the row has been created or deleted.roobsolete
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.3.1.100
passivePortTableThis table contains one row for each port on every provisioned passive circuit pack on the NE. Each list contains a list of attributes that pertain to the passive port.
SEQUENCE OF PassivePortEntry
.1.3.6.1.4.1.18070.2.2.1.4.4
passivePortEntryThe conceptual row object of the passive circuit pack port table.
PassivePortEntry
.1.3.6.1.4.1.18070.2.2.1.4.4.1
passivePortCpTypeIdxThe type of circuit pack on which the passive port is found.
CpType
.1.3.6.1.4.1.18070.2.2.1.4.4.1.1
passivePortShelfIdxThe number of the shelf on which the passive circuit pack port is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.4.1.2
passivePortSlotIdxThe number of the slot within which the passive circuit pack port is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.4.1.3
passivePortLineIdxIdentifies the multiplexed multi-channel optical facility instance associated with the targeted passive port.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.4.1.4
passivePortTypeIdxIdentifies the specific passive port on the circuit pack according to function.
PassivePortType
.1.3.6.1.4.1.18070.2.2.1.4.4.1.5
passivePortId1An optional name used to identify the passive circuit pack port facility.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.4.1.6
passivePortId2An optional identifier for the passive circuit pack port circuit.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.4.1.7
passivePortFiberTypeAn optional specification of the fiber type interfacing the passive circuit pack port.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.4.1.8
passivePortGridAn optional indication of the DWM grid that the link conforms to.rw
WDMGrid
.1.3.6.1.4.1.18070.2.2.1.4.4.1.9
passivePortNumChannelsAn optional indication of the number of channels that the link is carrying. This field does not apply to individual channel type ports.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.4.1.10
passivePortWavelengthAn indication of the wavelength that the port is carrying.ro
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.4.1.11
passivePortCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.4.1.12
passivePortCustom2A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.4.1.13
passivePortCustom3A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.4.1.14
passivePortRemoteIdIdentifies the remote node and port to which the passive card port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.4.1.15
passivePortRowStatusThe passive port table RowStatus object is not readable or writeable because all entries in the passive port table are automatically created and deleted when the circuit pack is created or deleted. This passive port row status object is used only in database change notifications to indicate if the row has been created or deleted.ro
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.4.1.100
ocnTableThis table contains one row for every provisioned SONET OC-N facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF OcnEntry
.1.3.6.1.4.1.18070.2.2.1.4.5
ocnEntryThe conceptual row object of the OC-N table.
OcnEntry
.1.3.6.1.4.1.18070.2.2.1.4.5.1
ocnTypeIdxThe specific type of OC-N signal which is provisioned.ro
OcnType
.1.3.6.1.4.1.18070.2.2.1.4.5.1.1
ocnShelfIdxThe number of the shelf on which the OC-N facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.5.1.2
ocnSlotIdxThe number of the slot within which the OC-N facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.5.1.3
ocnPortIdxThe number of the port on the circuit pack on which the OC-N facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.5.1.4
ocnOpticalPwrReceivedMinThThis is the optical power received minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.5.1.5
ocnOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.5.1.6
ocnOpticalPwrTransmittedMinThThis is the optical power transmitted minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.5.1.7
ocnOpticalPwrTransmittedMaxThThis is the optical power transmitted maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.5.1.8
ocnOpticalPwrReceivedThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.5.1.9
ocnOpticalPwrTransmittedThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.5.1.10
ocnBERThe Bit Error Rate measured on the received signal.ro
BERType
.1.3.6.1.4.1.18070.2.2.1.4.5.1.11
ocnBERThThe Bit Error Rate threshold above which the Signal Degrade condition is raised.rw
BERType
.1.3.6.1.4.1.18070.2.2.1.4.5.1.12
ocnPECAn optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the OC-N port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.5.1.13
ocnAdminStatusThe administrative status of the OC-N facility.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.5.1.14
ocnOperStatusThe reported operational status of the OC-N facility.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.5.1.15
ocnOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the OC-N facility.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.5.1.16
ocnAutoEnableTimerSpecifies the auto-enable timer for the targeted OC-N facility. This value only applies if the ocnAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.5.1.17
ocnActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.5.1.18
ocnWavelengthThe wavelength to be transmitted by the transceiver on the OC-N facility port. This is a mandatory object when a row of the OC-N table is created.rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.5.1.19
ocnVendorPN1An optionally provisioned part number used to validate the optical transceiver on the OC-N facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.5.1.20
ocnVendorPN2An optionally provisioned part number used to validate the optical transceiver on the OC-N facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.5.1.21
ocnVendorPN3An optionally provisioned part number used to validate the optical transceiver on the OC-N facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.5.1.22
ocnPhyPMMonIndicates if the OC-N facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.5.1.23
ocnLaserStatusAn indication of the operational status of the transceiver laser on the OC-N facility port.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.5.1.24
ocnId1Textual data recorded by the user to describe the provisioned OC-N facility in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.5.1.25
ocnFiberTypeAn optional specification of the fiber type that interfaces to the OC-N facility port.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.5.1.26
ocnCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.5.1.27
ocnTOHTransparencyUsed to configure whether the transport overhead of the the SONET OC-N facility is to be handled transparently or if it is to be terminated and regenerated. This object only applies to OC-48 client facilities on the 10G MXP circuit pack and the OC-12 and OC-3 client facilities on the 8-port 2.5G MXP circuit pack.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.5.1.28
ocnLineMappingUsed to configure the OTN configuration of the line port. If set to unmapped, there is no OTN digital wrapper added to the OC-192 or OC-48 facility. The odu1ToOtu2 and otu2 mapping is applicable to OC-192 line ports as follows: odu1ToOtu2 - the line port is configured as an OTN digitally wrapped OTU2 facility containing 4 ODU1 units. otu2 - the line port is configured as an OTN digitally wrapped OTU2 facility to which an OC-192 facility is directly mapped. The subOdu1ToOtu1 and otu1 mapping is applicable to OC-48 line ports as follows: subOdu1ToOtu1 - the line port is configured as an OTN digitally wrapped ODU1 facility containing 4 sub-ODU1 units. otu1 - the line port is configured as an OTN digitally wrapped OTU1 facility to which an OC-48 facility is directly mapped. This object applies only to the OC-192 line port of the 10G MXP circuit pack and the OC-48 line port of the 8-port 2.5G circuit pack.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.5.1.29
ocnProtSwEvtTypeIndicates the type of protection switching event that has occured on an OC-N facility.ro
ProtSwEvtType
.1.3.6.1.4.1.18070.2.2.1.4.5.1.30
ocnDCCTransparencyUsed to configure whether the Data Communications Channel (DCC) is transported transparently through the circuit pack. Specifically, this refers to the D1, D2 and D3 section DCC bytes. This object only applies to OC-48 client facilities on the 10G MXP circuit pack and the OC-12 client facilities on the 8-port 2.5G MXP circuit pack.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.5.1.31
ocnTransparencyChannelUsed to configure the STS1 channel number on which the DCC is transported. This object only applies to OC-48 client facilities on the 10G MXP circuit pack and the OC-12 client facilities on the 8-port 2.5G MXP circuit pack.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.5.1.32
ocnRemoteIdIdentifies the remote node and port to which the OC-n port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.5.1.33
ocnRowStatusUsed to control the addition and deletion of entries in the OC-N table, which in turn controls provisioning and deprovisioning of OC-N facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.5.1.100
stsnTableThis table contains one row for every created SONET STS-N facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF StsnEntry
.1.3.6.1.4.1.18070.2.2.1.4.6
stsnEntryThe conceptual row object of the STS-N table.
StsnEntry
.1.3.6.1.4.1.18070.2.2.1.4.6.1
stsnTypeIdxThe specific type of STS-N signal which is created.ro
StsnType
.1.3.6.1.4.1.18070.2.2.1.4.6.1.1
stsnShelfIdxThe number of the shelf on which the STS-N facility exists.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.6.1.2
stsnSlotIdxThe number of the slot within which the STS-N facility exists.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.6.1.3
stsnPortIdxThe number of the port on the circuit pack on which the STS-N facility exists.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.6.1.4
stsnIdxThe stsn channel number within the port in which the STS-N facility exists.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.6.1.5
stsnProtSwEvtTypeIndicates the type of protection switching event that has occured on an STS-N facility.ro
ProtSwEvtType
.1.3.6.1.4.1.18070.2.2.1.4.6.1.6
stsnBERThe Bit Error Rate measured on the received channel.ro
BERType
.1.3.6.1.4.1.18070.2.2.1.4.6.1.7
stsnBERThThe Bit Error Rate threshold above which the Signal Degrade condition is raised.ro
BERType
.1.3.6.1.4.1.18070.2.2.1.4.6.1.8
stsnProtSwStatusIf the STS-N facility is configured as part of a protection grouping, this object indicates its protection status.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.6.1.9
stmnTableThis table contains one row for every provisioned SDH STM-N facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF StmnEntry
.1.3.6.1.4.1.18070.2.2.1.4.7
stmnEntryThe conceptual row object of the STM-N table.
StmnEntry
.1.3.6.1.4.1.18070.2.2.1.4.7.1
stmnTypeIdxThe specific type of STM-N signal which is provisioned.ro
StmnType
.1.3.6.1.4.1.18070.2.2.1.4.7.1.1
stmnShelfIdxThe number of the shelf on which the STM-N facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.7.1.2
stmnSlotIdxThe number of the slot within which the STM-N facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.7.1.3
stmnPortIdxThe number of the port on the circuit pack on which the STM-N facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.7.1.4
stmnOpticalPwrReceivedMinThThis is the optical power received minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.7.1.5
stmnOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.7.1.6
stmnOpticalPwrTransmittedMinThThis is the optical power transmitted minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.7.1.7
stmnOpticalPwrTransmittedMaxThThis is the optical power transmitted maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.7.1.8
stmnOpticalPwrReceivedThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.7.1.9
stmnOpticalPwrTransmittedThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.7.1.10
stmnBERThe Bit Error Rate measured on the received signal.ro
BERType
.1.3.6.1.4.1.18070.2.2.1.4.7.1.11
stmnBERThThe Bit Error Rate threshold above which the Signal Degrade condition is raised.rw
BERType
.1.3.6.1.4.1.18070.2.2.1.4.7.1.12
stmnPECAn optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the STM-N port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.7.1.13
stmnAdminStatusThe administrative status of the STM-N facility.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.7.1.14
stmnOperStatusThe reported operational status of the STM-N facility.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.7.1.15
stmnOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the STM-N facility.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.7.1.16
stmnAutoEnableTimerSpecifies the auto-enable timer for the targeted STM-N facility. This value only applies if the stmnAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.7.1.17
stmnActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.7.1.18
stmnWavelengthThe wavelength to be transmitted by the transceiver on the STM-N facility port. This is a mandatory object when a row of the STM-N table is created.rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.7.1.19
stmnVendorPN1An optionally provisioned part number used to validate the optical transceiver on the STM-N facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.7.1.20
stmnVendorPN2An optionally provisioned part number used to validate the optical transceiver on the STM-N facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.7.1.21
stmnVendorPN3An optionally provisioned part number used to validate the optical transceiver on the STM-N facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.7.1.22
stmnPhyPMMonIndicates if the STM-N facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.7.1.23
stmnLaserStatusAn indication of the operational status of the transceiver laser on the STM-N facility port.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.7.1.24
stmnId1Textual data recorded by the user to describe the provisioned STM-N facility in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.7.1.25
stmnFiberTypeAn optional specification of the fiber type that interfaces to the STM-N facility port.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.7.1.26
stmnCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.7.1.27
stmnTOHTransparencyUsed to configure whether the transport overhead of the the SDH STM-N facility is to be handled transparently or if it is to be terminated and regenerated. This object only applies to STM-16 client facilities on the 10G MXP circuit pack and the STM-4 and STM-1 client facilities on the 8-port 2.5G MXP circuit pack.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.7.1.28
stmnLineMappingUsed to configure the OTN configuration of the line port. If set to unmapped, there is no OTN digital wrapper added to the STM-64 or STM-16 facility. The odu1ToOtu2 and otu2 mapping is applicable to STM-64 line ports as follows: odu1ToOtu2 - the line port is configured as an OTN digitally wrapped OTU2 facility containing 4 ODU1 units. otu2 - the line port is configured as an OTN digitally wrapped OTU2 facility to which an STM-64 facility is directly mapped. The subOdu1ToOtu1 and otu1 mapping is applicable to STM-16 line ports as follows: subOdu1ToOtu1 - the line port is configured as an OTN digitally wrapped ODU1 facility containing 4 sub-ODU1 units. otu1 - the line port is configured as an OTN digitally wrapped OTU1 facility to which an STM-16 facility is directly mapped. This object applies only to the STM-64 line port of the 10G MXP circuit pack and the STM-16 line port of the 8-port 2.5G circuit pack.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.7.1.29
stmnProtSwEvtTypeIndicates the type of protection switching event that has occured on an STM-N facility.ro
ProtSwEvtType
.1.3.6.1.4.1.18070.2.2.1.4.7.1.30
stmnDCCTransparencyUsed to configure whether the Data Communications Channel (DCC) is transported transparently through the circuit pack. Specifically, this refers to the D1, D2 and D3 section DCC bytes. This object only applies to STM-16 client facilities on the 10G MXP circuit pack and the STM-4 client facilities on the 8-port 2.5G MXP circuit pack.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.7.1.31
stmnTransparencyChannelUsed to configure the VC4 channel number on which the DCC is transported. This object only applies to STM-16 client facilities on the 10G MXP circuit pack and the STM-4 client facilities on the 8-port 2.5G MXP circuit pack.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.7.1.32
stmnRemoteIdIdentifies the remote node and port to which the STM-n port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.7.1.33
stmnRowStatusUsed to control the addition and deletion of entries in the STM-N table, which in turn controls provisioning and deprovisioning of STM-N facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.7.1.100
vcnTableThis table contains one row for every created SDH VC-N facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF VcnEntry
.1.3.6.1.4.1.18070.2.2.1.4.8
vcnEntryThe conceptual row object of the VC-N table.
VcnEntry
.1.3.6.1.4.1.18070.2.2.1.4.8.1
vcnTypeIdxThe specific type of VC-N signal which is created.ro
VcnType
.1.3.6.1.4.1.18070.2.2.1.4.8.1.1
vcnShelfIdxThe number of the shelf on which the VC-N facility exists.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.8.1.2
vcnSlotIdxThe number of the slot within which the VC-N facility exists.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.8.1.3
vcnPortIdxThe number of the port on the circuit pack on which the VC-N facility exists.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.8.1.4
vcnIdxThe vcn channel number within the port in which the VC-N facility exists.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.8.1.5
vcnProtSwEvtTypeIndicates the type of protection switching event that has occured on a VC-N facility.ro
ProtSwEvtType
.1.3.6.1.4.1.18070.2.2.1.4.8.1.6
vcnBERThe Bit Error Rate measured on the received channel.ro
BERType
.1.3.6.1.4.1.18070.2.2.1.4.8.1.7
vcnBERThThe Bit Error Rate threshold above which the Signal Degrade condition is raised.ro
BERType
.1.3.6.1.4.1.18070.2.2.1.4.8.1.8
vcnProtSwStatusIf the VC-N facility is configured as part of a protection grouping, this object indicates its protection status.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.8.1.9
geTableThis table contains one row for every provisioned Gigabit Ethernet (GE) facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF GeEntry
.1.3.6.1.4.1.18070.2.2.1.4.9
geEntryThe conceptual row object of the GE table.
GeEntry
.1.3.6.1.4.1.18070.2.2.1.4.9.1
geShelfIdxThe number of the shelf on which the GE facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.9.1.1
geSlotIdxThe number of the slot within which the GE facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.9.1.2
gePortIdxThe number of the port on the circuit pack on which the GE facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.9.1.3
geOpticalPwrReceivedMinThThis is the optical power received minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.9.1.4
geOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.9.1.5
geOpticalPwrTransmittedMinThThis is the optical power transmitted minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.9.1.6
geOpticalPwrTransmittedMaxThThis is the optical power transmitted maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.9.1.7
geOpticalPwrReceivedThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.9.1.8
geOpticalPwrTransmittedThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.9.1.9
gePECAn optionally provisioned transceiver Product Equipment Code used to validate the physically present transceiver on the Gigabit Ethernet port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.9.1.10
geAdminStatusThe administrative status of the Gigabit Ethernet facility.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.9.1.11
geOperStatusThe reported operational status of the Gigabit Ethernet facility.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.9.1.12
geOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the Gigabit Ethernet facility.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.9.1.13
geAutoEnableTimerSpecifies the auto-enable timer for the targeted Gigabit Ethernet facility. This value only applies if the geAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.9.1.14
geActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.9.1.15
geWavelengthThe wavelength to be transmitted by the transceiver on the Gigabit Ethernet facility port. This is a mandatory object when a row of the Gigabit Ethernet table is created.rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.9.1.16
geVendorPN1An optionally provisioned part number used to validate the optical transceiver on the Gigabit Ethernet facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.9.1.17
geVendorPN2An optionally provisioned part number used to validate the optical transceiver on the Gigabit Ethernet facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.9.1.18
geVendorPN3An optionally provisioned part number used to validate the optical transceiver on the Gigabit Ethernet facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.9.1.19
gePhyPMMonIndicates if the Gigabit Ethernet facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.9.1.20
geFPSDIndicates if the Gigabit Ethernet facility is configured for Fault Propagation Shut Down.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.9.1.21
geLaserStatusAn indication of the operational status of the transceiver laser on the Gigabit Ethernet facility port.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.9.1.22
geId1Textual data recorded by the user to describe the provisioned Gigabit Ethernet facility in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.9.1.23
geFiberTypeAn optional specification of the fiber type that interfaces to the Gigabit Ethernet facility port.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.9.1.24
geCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.9.1.25
geSpeedThe speed of the Gigabit Ethernet facility link.ro
Gauge32 UNITS "Mbps"
.1.3.6.1.4.1.18070.2.2.1.4.9.1.26
geDuplexThe duplex mode of the Gigabit Ethernet facility interface.ro
DuplexModeType
.1.3.6.1.4.1.18070.2.2.1.4.9.1.27
geMediaRateThe configured media rate of the Gigabit Ethernet facility interface.rw
MediaRateType
.1.3.6.1.4.1.18070.2.2.1.4.9.1.28
geMTUThe MTU size for the Gigabit Ethernet facility interface.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.4.9.1.29
geMACAddrThe MAC address of the Gigabit Ethernet facility interface.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.9.1.30
geGfpModeConfigures the mapping of GE facility port onto the line port using either framed or transparent general framing protocol.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.9.1.31
geFlowControlConfigures the flow control setting of GE facility as transparent or locally enabled.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.9.1.32
geRemoteIdIdentifies the remote node and port to which the gigabit ethernet port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.9.1.33
geRowStatusUsed to control the addition and deletion of entries in the Gigabit Ethernet table, which in turn controls provisioning and deprovisioning of Gigabit Ethernet facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.9.1.100
feTableThis table contains one row for every provisioned Fast Ethernet (FE) facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF FeEntry
.1.3.6.1.4.1.18070.2.2.1.4.10
feEntryThe conceptual row object of the FE table.
FeEntry
.1.3.6.1.4.1.18070.2.2.1.4.10.1
feShelfIdxThe number of the shelf on which the FE facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.10.1.1
feSlotIdxThe number of the slot within which the FE facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.10.1.2
fePortIdxThe number of the port on the circuit pack on which the FE facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.10.1.3
feId1Textual data recorded by the user to describe the provisioned Fast Ethernet facility in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.10.1.4
feCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.10.1.5
feSpeedThe speed of the Fast Ethernet facility link.ro
Gauge32 UNITS "Mbps"
.1.3.6.1.4.1.18070.2.2.1.4.10.1.6
feDuplexThe duplex mode of the Fast Ethernet facility interface.ro
DuplexModeType
.1.3.6.1.4.1.18070.2.2.1.4.10.1.7
feMediaRateThe configured media rate of the Fast Ethernet facility interface.ro
MediaRateType
.1.3.6.1.4.1.18070.2.2.1.4.10.1.8
feMTUThe MTU size for the Fast Ethernet facility interface.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.4.10.1.9
feMACAddrThe MAC address of the Fast Ethernet facility interface.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.10.1.10
feRemoteIdIdentifies the remote node and port to which the fast ethernet port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.10.1.11
feRowStatusUsed to control the addition and deletion of entries in the Fast Ethernet table, which in turn controls provisioning and deprovisioning of Fast Ethernet facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.10.1.100
vcgTableThis table contains one row for every provisioned Virtual Concatenation Group (VCG) enitity on the system. Each row contains a list of attributes that pertain to the VCG.
SEQUENCE OF VcgEntry
.1.3.6.1.4.1.18070.2.2.1.4.11
vcgEntryThe conceptual row object of the VCG table.
VcgEntry
.1.3.6.1.4.1.18070.2.2.1.4.11.1
vcgShelfIdxThe number of the shelf on which the VCG entity is located.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.11.1.1
vcgSlotIdxThe number of the slot within which the VCG entity is located.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.11.1.2
vcgPortIdxThe number of the port on the circuit pack on which the VCG entity is located.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.11.1.3
vcgIdxThe number of the VCG within the identified port.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.11.1.4
vcgTypeThe format of the VCG.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.11.1.5
vcgTimeSlotIndicesA textual listing of the time slot indices used for the VCG. The information is formatted as a comma-separated list of of individual time slot indices or time slot index ranges. For example, a value of 'X-Y,Z' indicates that the VCG includes all time slots in the range of X to Y, plus Z, when X, Y, and Z are all integers.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.11.1.6
vcgRowStatusUsed to control the addition and deletion of entries in the VCG table, which in turn controls provisioning and deprovisioning of Virtual Concatenation groups. Manual creation and deletion of VCGs is supported only on the 10G MXP, as all VCGs on the 2.5G MXP are auto-created and deleted.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.11.1.100
fcTableThis table contains one row for every provisioned fiber channel facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF FcEntry
.1.3.6.1.4.1.18070.2.2.1.4.12
fcEntryThe conceptual row object of the fiber channel table.
FcEntry
.1.3.6.1.4.1.18070.2.2.1.4.12.1
fcShelfIdxThe number of the shelf on which the fiber channel facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.12.1.1
fcSlotIdxThe number of the slot within which the fiber channel facility is provisioned.ro
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.4.12.1.2
fcPortIdxThe number of the port on the circuit pack on which the fiber channel facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.12.1.3
fcRateThe rate of the fiber channel signal which is provisioned.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.12.1.4
fcOpticalPwrReceivedMinThThis is the optical power received minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.12.1.5
fcOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.12.1.6
fcOpticalPwrTransmittedMinThThis is the optical power transmitted minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.12.1.7
fcOpticalPwrTransmittedMaxThThis is the optical power transmitted maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.12.1.8
fcOpticalPwrReceivedThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.12.1.9
fcOpticalPwrTransmittedThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.12.1.10
fcPECAn optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the fiber channel port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.12.1.11
fcAdminStatusThe administrative status of the fiber channel facility.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.12.1.12
fcOperStatusThe reported operational status of the fiber channel facility.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.12.1.13
fcOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the fiber channel facility.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.12.1.14
fcAutoEnableTimerSpecifies the auto-enable timer for the targeted fiber channel facility. This value only applies if the fcAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.12.1.15
fcActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.12.1.16
fcWavelengthThe wavelength to be transmitted by the transceiver on the fiber channel facility port. This is a mandatory object when a row of the fiber channel table is created.rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.12.1.17
fcVendorPN1An optionally provisioned part number used to validate the optical transceiver on the fiber channel facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.12.1.18
fcVendorPN2An optionally provisioned part number used to validate the optical transceiver on the fiber channel facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.12.1.19
fcVendorPN3An optionally provisioned part number used to validate the optical transceiver on the fiber channel facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.12.1.20
fcPhyPMMonIndicates if the fiber channel facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.12.1.21
fcFPSDIndicates if the Fiber Channel facility is configured for Fault Propagation Shut Down.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.12.1.22
fcLaserStatusAn indication of the operational status of the transceiver laser on the fiber channel facility port.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.12.1.23
fcId1Textual data recorded by the user to describe the provisioned fiber channel facility in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.12.1.24
fcFiberTypeAn optional specification of the fiber type that interfaces to the fiber channel facility port.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.12.1.25
fcCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.12.1.26
fcGfpModeConfigures the mapping of fiber channel facility port onto the line port using GFP. Only the transparent mapping is supported for fiber channel facilities.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.12.1.27
fcRemoteIdIdentifies the remote node and port to which the fiber channel port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.12.1.28
fcRowStatusUsed to control the addition and deletion of entries in the fiber channel table, which in turn controls provisioning and deprovisioning of fiber channel facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.12.1.100
ethIntfTableThis table contains one row for every provisioned Ethernet facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF EthIntfEntry
.1.3.6.1.4.1.18070.2.2.1.4.14
ethIntfEntryThe conceptual row object of the ethIntfTable table.
EthIntfEntry
.1.3.6.1.4.1.18070.2.2.1.4.14.1
ethIntfShelfIdxThe number of the shelf in which the Ethernet facility resides.ro
INTEGER (1 | 11 | 21 | 31)
.1.3.6.1.4.1.18070.2.2.1.4.14.1.1
ethIntfSlotIdxThe number of the slot in which the Ethernet facility resides.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.14.1.2
ethIntfPortTypeIdxThe type of the port on the circuit pack.ro
PvxL1PortType
.1.3.6.1.4.1.18070.2.2.1.4.14.1.3
ethIntfPortIdxThe number of the port on the circuit pack on which the ethernet facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.14.1.4
ethIntfOpticalPwrReceivedMinThThis is the optical power received minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.14.1.5
ethIntfOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.14.1.6
ethIntfOpticalPwrTransmittedMinThThis is the optical power transmitted minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.14.1.7
ethIntfOpticalPwrTransmittedMaxThThis is the optical power transmitted maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.14.1.8
ethIntfOpticalPwrReceivedThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.14.1.9
ethIntfOpticalPwrTransmittedThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.14.1.10
ethIntfPECAn optionally provisioned transceiver Product Equipment Code used to validate the physically present transceiver on the Ethernet port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.14.1.11
ethIntfAdminStatusThe administrative status of the Ethernet facility.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.12
ethIntfOperStatusThe reported operational status of the Ethernet facility.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.14.1.13
ethIntfOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the Ethernet facility.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.14.1.14
ethIntfAutoEnableTimerSpecifies the auto-enable timer for the targeted Ethernet facility. This value only applies if the AdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.14.1.15
ethIntfActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.14.1.16
ethIntfWavelengthThe wavelength to be transmitted by the transceiver on the Gigabit Ethernet facility port. This is a mandatory object when a row of the Ethernet table is created.rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.14.1.17
ethIntfVendorPN1An optionally provisioned part number used to validate the optical transceiver on the Ethernet facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.14.1.18
ethIntfVendorPN2An optionally provisioned part number used to validate the optical transceiver on the Ethernet facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.14.1.19
ethIntfVendorPN3An optionally provisioned part number used to validate the optical transceiver on the Ethernet facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.14.1.20
ethIntfPhyPMMonIndicates if the Ethernet facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.21
ethIntfFPSDIndicates if the Ethernet facility is configured for Fault Propagation Shut Down.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.22
ethIntfLaserStatusAn indication of the operational status of the transceiver laser on the Ethernet facility port.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.23
ethIntfId1Textual data recorded by the user to describe the provisioned facility in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.14.1.24
ethIntfFiberTypeAn optional specification of the fiber type that interfaces to the Ethernet facility port.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.14.1.25
ethIntfCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.14.1.26
ethIntfSpeedThe speed of the Ethernet facility link. This object is mandatory to create a new facility and determines the type of interface, based on speed.ro
Gauge32 UNITS "Mbps"
.1.3.6.1.4.1.18070.2.2.1.4.14.1.27
ethIntfDuplexThe duplex mode of the Ethernet facility interface.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.28
ethIntfMediaRateThe configured media rate of the Ethernet facility interface. For 10 GE interfaces, the media rate can only be autoNegotiated.rw
MediaRateType
.1.3.6.1.4.1.18070.2.2.1.4.14.1.29
ethIntfMTUThe MTU size for the Ethernet facility interface.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.14.1.30
ethIntfLinkStatusThis object provides the link status information regarding the particular interface.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.31
ethIntfLagIdThis object provides the information regarding the LAG Id of the particular interface.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.14.1.32
ethIntfLagPortPriorityThis object provides the information for lag port priority of the particular interface.rw
Integer32
.1.3.6.1.4.1.18070.2.2.1.4.14.1.33
ethIntfBERThe Signal Degrade Bit Error Ratio (SDBER) is used to configure the error rate threshold above which a Signal Degrade is declared.rw
BERType
.1.3.6.1.4.1.18070.2.2.1.4.14.1.37
ethIntfMACAddrThe MAC address of the interface.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.14.1.39
ethIntfLineMappingFor 10 GE interfaces, both 10 GE LAN PHY and OTU2 encapsulated 10GE LAN PHY will be supported. The line mapping attribute allow provisioning of either of the protocol. This attributes applies to 10 GE interfaces only. When a 10 GE interface is configured as a stacking port, this field is set to stacking. NOTE: This parameter does not apply to gigabitEthernet type interfaces, attempts to set this for gigE port types will fail. Reading this object for non-10GigE interfaces will return notApplicable.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.40
ethIntfErrorCorrectionFor 10G in OTU2 line-mapping mode, this object specifies the error correction mode. For interfaces in tenlanphy line-mapping mode, this object must be none. Attempts to set it to any other value while in tenglanphy mode will fail. NOTE: This parameter does not apply to gigabitEthernet type interfaces, attempts to set this for gigE port types will fail.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.41
ethIntfLpbkOpCmdUsed to perform a loopback operation on a transceiver facility as follows: - oprLpbk: operates a loopback on the transceiver - rlsLpbk: causes a previously invoked loopback to be released When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.42
ethIntfRemoteIdIdentifies the remote node and port to which the PVX ethernet port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.14.1.43
ethIntfMirrorConfigMirror configuration for the physical ethernet portrw
MirrorConfigType
.1.3.6.1.4.1.18070.2.2.1.4.14.1.44
ethIntfLldpAdminStatusThe administratively desired status of the local LLDP agent. If the associated ethIntfLldpAdminStatus object has a value of 'enabled(1)', then the LLDP agent will transmit and receive LLDP frames on this port. If the associated ethIntfLldpAdminStatus object has a value of 'disabled(2)', then LLDP agent will not transmit or receive LLDP frames on this port. If there is remote systems information which is received on this port and stored in other tables, before the port's ethIntfLldpAdminStatus becomes disabled, then the information will naturally age out.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.14.1.45
ethIntfLldpRemChassisIdSubtypeThe type of encoding used to identify the chassis associated with the remote system.ro
LldpChassisIdSubtype
.1.3.6.1.4.1.18070.2.2.1.4.14.1.46
ethIntfLldpRemChassisIdThe string value used to identify the chassis component associated with the remote system.ro
LldpChassisId
.1.3.6.1.4.1.18070.2.2.1.4.14.1.47
ethIntfLldpRemPortIdSubtypeThe type of port identifier encoding used in the associated 'ethIntfLldpRemPortId' object.ro
LldpPortIdSubtype
.1.3.6.1.4.1.18070.2.2.1.4.14.1.48
ethIntfLldpRemPortIdThe string value used to identify the port component associated with the remote system.ro
LldpPortId
.1.3.6.1.4.1.18070.2.2.1.4.14.1.49
ethIntfBouncingStateChangeCountCount of the Ethernet facility operational state changes sinse last rebootro
Integer32
.1.3.6.1.4.1.18070.2.2.1.4.14.1.50
ethIntfRowStatusUsed to control the addition and deletion of entries in the Ethernet table, which in turn controls provisioning and deprovisioning of Ethernet facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.14.1.100
odunTableThis table contains one row for every ODU-N facility on the system.
SEQUENCE OF OdunEntry
.1.3.6.1.4.1.18070.2.2.1.4.15
odunEntryThe conceptual row object of the ODU-N table.
OdunEntry
.1.3.6.1.4.1.18070.2.2.1.4.15.1
odunTypeIdxThe specific type of ODU-N which is provisioned.ro
OdunType
.1.3.6.1.4.1.18070.2.2.1.4.15.1.1
odunShelfIdxThe number of the shelf on which the ODU-N facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.15.1.2
odunSlotIdxThe number of the slot within which the ODU-N facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.15.1.3
odunPortIdxThe number of the port on the circuit pack on which the ODU-N facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.15.1.4
odunIdxThe ODU-N channel number within the port in which the ODU-N facility exists.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.15.1.5
briTableThis table contains one row for every provisioned Bit Rate Independent (BRI) facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF BriEntry
.1.3.6.1.4.1.18070.2.2.1.4.16
briEntryThe conceptual row object of the BRI table.
BriEntry
.1.3.6.1.4.1.18070.2.2.1.4.16.1
briShelfIdxThe number of the shelf on which the BRI facility is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.4.16.1.1
briSlotIdxThe number of the slot within which the BRI facility is provisioned.ro
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.4.16.1.2
briPortIdxThe number of the port on the circuit pack on which the BRI facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.4.16.1.3
briProtocolThe protocol of the BRI signal which is provisioned.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.16.1.4
briOpticalPwrReceivedMinThThis is the optical power received minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.16.1.5
briOpticalPwrReceivedMaxThThis is the optical power received maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.16.1.6
briOpticalPwrTransmittedMinThThis is the optical power transmitted minimum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.16.1.7
briOpticalPwrTransmittedMaxThThis is the optical power transmitted maximum threshold.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.16.1.8
briOpticalPwrReceivedThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.16.1.9
briOpticalPwrTransmittedThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.4.16.1.10
briPECAn optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the BRI port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.16.1.11
briAdminStatusThe administrative status of the BRI facility.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.4.16.1.12
briOperStatusThe reported operational status of the BRI facility.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.4.16.1.13
briOperStatQlfrThis is a textual list of qualifiers about the reported operational status of the BRI facility.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.4.16.1.14
briAutoEnableTimerSpecifies the auto-enable timer for the targeted BRI facility. This value only applies if the briAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.16.1.15
briActAutoEnableTimerIndicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00.ro
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.4.16.1.16
briWavelengthThe wavelength to be transmitted by the transceiver on the BRI facility port. This is a mandatory object when a row of the fiber channel table is created.rw
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.16.1.17
briVendorPN1An optionally provisioned part number used to validate the optical transceiver on the BRI facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.16.1.18
briVendorPN2An optionally provisioned part number used to validate the optical transceiver on the BRI facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.16.1.19
briVendorPN3An optionally provisioned part number used to validate the optical transceiver on the BRI facility port.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.16.1.20
briPhyPMMonIndicates if the BRI facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.16.1.21
briLaserStatusAn indication of the operational status of the transceiver laser on the BRI facility port.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.4.16.1.22
briId1Textual data recorded by the user to describe the provisioned BRI facility in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.4.16.1.23
briFiberTypeAn optional specification of the fiber type that interfaces to the BRI facility port.rw
FiberType
.1.3.6.1.4.1.18070.2.2.1.4.16.1.24
briCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.16.1.25
briBitRateThe bit rate transmitted by the BRI facility port in Mbps.ro
FixedX100
.1.3.6.1.4.1.18070.2.2.1.4.16.1.26
briRemoteIdIdentifies the remote node and port to which the Bitrate Independent port is connected, in the format prescribed by the PSM network management system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.16.1.27
briRowStatusUsed to control the addition and deletion of entries in the BRI table, which in turn controls provisioning and deprovisioning of BRI facilities.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.4.16.1.100
dataComms
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.5
oscTableThis table contains one row for every provisioned optical supervisory channel interface on the NE. Each row contains a list of attributes that pertain to the OSC.
SEQUENCE OF OscEntry
.1.3.6.1.4.1.18070.2.2.1.5.1
oscEntryThe conceptual row object of the optical supervisory channel table.
OscEntry
.1.3.6.1.4.1.18070.2.2.1.5.1.1
oscShelfIdxThe number of the shelf on which the OSC is provisioned.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.5.1.1.1
oscSlotIdxThe number of the slot in which the OSC is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.5.1.1.2
oscIdxThe number of the port on the circuit pack on which the OSC is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.5.1.1.3
oscAdminStatusThe administrative status of the OSC interface.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.5.1.1.4
oscOperStatusThe reported operational status of the OSC interface.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.5.1.1.5
oscOperStatQlfrA textual list of qualifiers for the reported operational status of the OSC interface.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.5.1.1.6
oscCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.1.1.7
oscTypeThe type of physical communication medium attached to the OSC interface.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.5.1.1.8
oscUnmbrdIndicates whether or not the OSC interface is the type that requires an IP address to be assigned.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.1.1.9
oscSpeedThe speed of the OSC link.ro
Gauge32 UNITS "Mbps"
.1.3.6.1.4.1.18070.2.2.1.5.1.1.10
oscDuplexThe duplex mode of the OSC interface.ro
DuplexModeType
.1.3.6.1.4.1.18070.2.2.1.5.1.1.11
oscMediaRateThe configured media rate of the OSC interface.ro
MediaRateType
.1.3.6.1.4.1.18070.2.2.1.5.1.1.12
oscMTUThe MTU size for the OSC interface.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.5.1.1.13
oscMACAddrThe MAC address of the OSC interface.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.1.1.14
oscIPAddrThe IP Address of the OSC interface. A value of 0.0.0.0 indicates that the interface is not assigned an IP address.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.5.1.1.15
oscIPMaskThe IP Subnet Mask of the OSC interface.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.5.1.1.16
oscIPBcastThe IP broadcast address of the OSC interface.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.5.1.1.17
oscRowStatusUsed to control the addition and deletion of entries in the OSC table, which in turn controls provisioning and deprovisioning of OSC interfaces.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.1.1.100
netMgmtTableThis table contains one row for every network management interface on the NE. Each row contains a list of attributes that pertain to the interface.
SEQUENCE OF NetMgmtEntry
.1.3.6.1.4.1.18070.2.2.1.5.2
netMgmtEntryThe conceptual row object of the network management interface table.
NetMgmtEntry
.1.3.6.1.4.1.18070.2.2.1.5.2.1
netMgmtIdxIdentifies the specific management interface.
Enumeration
.1.3.6.1.4.1.18070.2.2.1.5.2.1.1
netMgmtAdminStatusThe administrative status of the management interface.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.5.2.1.2
netMgmtOperStatusThe reported operational status of the management interface.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.5.2.1.3
netMgmtOperStatQlfrA textual list of qualifiers for the reported operational status of the management interface.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.5.2.1.4
netMgmtIPAddrThe IP Address of the management interface.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.5.2.1.5
netMgmtIPMaskThe IP Subnet Mask of the management interface.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.5.2.1.6
netMgmtIPBcastThe IP broadcast address of the management interface.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.5.2.1.7
netMgmtCustom1A variable length text string for operating company use.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.2.1.8
netMgmtTypeThe type of physical communication medium attached to the management interface.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.5.2.1.9
netMgmtUnmbrdIndicates whether or not the management interface is the type that requires an IP address to be assigned.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.2.1.10
netMgmtSpeedThe speed of the management interface link.ro
Gauge32 UNITS "Mbps"
.1.3.6.1.4.1.18070.2.2.1.5.2.1.11
netMgmtDuplexThe duplex mode of the management interface.ro
DuplexModeType
.1.3.6.1.4.1.18070.2.2.1.5.2.1.12
netMgmtMediaRateThe configured media rate of the management interface.ro
MediaRateType
.1.3.6.1.4.1.18070.2.2.1.5.2.1.13
netMgmtMTUThe MTU size for this management interface.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.5.2.1.14
netMgmtMACAddrThe MAC address of the management interface.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.2.1.15
serialTableA table of serial communication ports on the network element. Each row contains a list of attributes that pertain to a given serial port.
SEQUENCE OF SerialEntry
.1.3.6.1.4.1.18070.2.2.1.5.3
serialEntryThe conceptual row object for the serial port table.
SerialEntry
.1.3.6.1.4.1.18070.2.2.1.5.3.1
serialPortIdxThe serial port instance on the NE.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.5.3.1.1
serialBaudRateThe baud rate of the serial port.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.5.3.1.2
serialDataBitsThe number of data bits of the serial port.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.5.3.1.3
serialParityThe parity value of the serial port.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.5.3.1.4
serialStopBitsThe number of stop bits of the serial port.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.5.3.1.5
gcc0ConfigTableA table of GCC0 configuration information. This table contains one row for every provisioned GCC0.
SEQUENCE OF Gcc0ConfigEntry
.1.3.6.1.4.1.18070.2.2.1.5.4
gcc0ConfigEntryA conceptual row that contains GCC0 configuration information of an interface. Each instance must correspond to an instance of an OTN Port capable of supporting GCC. Instances of this conceptual row persist across agent restarts.
Gcc0ConfigEntry
.1.3.6.1.4.1.18070.2.2.1.5.4.1
gcc0ConfigCpTypeIdxThe specific type of circuit pack provisioned.
CpType
.1.3.6.1.4.1.18070.2.2.1.5.4.1.1
gcc0ConfigShelfIdxThe number of the shelf on which the gcc0 is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.5.4.1.2
gcc0ConfigSlotIdxThe number of the slot in which the gcc0 is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.5.4.1.3
gcc0ConfigPortIdxThe number of the port on the circuit pack on which the gcc0 provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.5.4.1.4
gcc0ConfigModeThe desired mode to which the gcc0 is to be provisioned.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.5.4.1.5
gcc0ConfigAdminStatusThe administrative status of the gcc.rw
AdminStatus
.1.3.6.1.4.1.18070.2.2.1.5.4.1.6
gcc0ConfigOperStatusThe reported operational status of the gcc.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.5.4.1.7
gcc0ConfigOperStatQlfrA textual list of qualifiers of the reported operational status of the gcc.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.5.4.1.8
gcc0ConfigRowStatusThis columnar object is used for creating and deleting a conceptual row of the gcc0 config table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.4.1.9
ipExtInterfaceTable
SEQUENCE OF IPExtInterfaceTableEntry
.1.3.6.1.4.1.18070.2.2.1.5.5
ipExtInterfaceTableEntry
IPExtInterfaceTableEntry
.1.3.6.1.4.1.18070.2.2.1.5.5.1
pvxL2IntfSubPortNumberA number indentifying a entity smaller than and contained in a port. At this time, this value is unused and must be zero.
Integer32
.1.3.6.1.4.1.18070.2.2.1.5.5.1.1
ipExtIntfPrimaryStateThe reported operational status of the IP Interface.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.5.5.1.2
ipExtIntfSecondaryStateA textual list of qualifiers for the reported operational status of the IP Interfacero
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.5.5.1.3
ipExtIntfCmdPrimaryStatero
OperStatus
.1.3.6.1.4.1.18070.2.2.1.5.5.1.4
ipExtIntfNumberedStatusSet to true if this is a numbered interface and false if it is unnumbered.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.5.1.5
ipExtIntfAddressTypeThe type of addresses (v4/v6) used in this row of this MIB. Currently only ipv4 is allowed in this table.ro
InetAddressType
.1.3.6.1.4.1.18070.2.2.1.5.5.1.6
ipExtIntfAddressThe IP Address associated with the interface.ro
InetAddress
.1.3.6.1.4.1.18070.2.2.1.5.5.1.7
ipExtIntfSubnetMaskThe sub-net mask associated with the interface.ro
InetAddress
.1.3.6.1.4.1.18070.2.2.1.5.5.1.8
ipExtIntfProxyARPStatusNot currently implemented.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.5.1.9
ipExtIntfDescriptionA string describing the interface.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.5.5.1.10
ipExtIntfMACAddrThe MAC address associated with the interface, if applicable. All zeros for a non-MAC interface.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.5.1.11
ipExtIntfOperStatusro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.5.5.1.12
ipExtIntfTypeA value describing the type of interface.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.5.5.1.13
ipExtIntfBroadcastAddressThe broadcast address associated with the interface.ro
InetAddress
.1.3.6.1.4.1.18070.2.2.1.5.5.1.14
ipExtIntfSpeedro
Gauge32
.1.3.6.1.4.1.18070.2.2.1.5.5.1.15
ipExtIntfModeIs the interface full or half-duplex?ro
DuplexModeType
.1.3.6.1.4.1.18070.2.2.1.5.5.1.16
ipExtIntfMTUSizeThe Maximum Transmission Unit for the interface.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.5.5.1.17
ipExtIntfLastChangero
Integer32
.1.3.6.1.4.1.18070.2.2.1.5.5.1.18
ipExtIntfGatewayThe gateway IP address associated with the interface.ro
InetAddress
.1.3.6.1.4.1.18070.2.2.1.5.5.1.19
ipExtIntfRowStatusThis columnar object is used for creating and deleting a conceptual row of the ipExtIntf table.ro
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.5.5.1.100
performance
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.6
oaCrntPMTableA table of current performance monitoring statistics collected for the optical amplifier facilities on the NE.
SEQUENCE OF OaCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.1
oaCrntPMEntryThe row entry object of the optical amplifier current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given optical amplifier.
OaCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.1.1
oaCrntPMOaTypeIdxThe type of the optical amplifier targeted for PM retrieval.
OaType
.1.3.6.1.4.1.18070.2.2.1.6.1.1.1
oaCrntPMShelfIdxThe number of the shelf on which the amplifier targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.2
oaCrntPMSlotIdxThe number of the slot within which the optical amplifier targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.1.1.3
oaCrntPMOaIdxThe number of the amplifier port on which the circuit pack for PMs is targeted.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.1.1.4
oaCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.1.1.5
oaCrntPMCaseTempValueThe optical amplifier case temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.6
oaCrntPMCaseTempTimeStampThe date and time stamp of the case temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.7
oaCrntPMCaseTempValidityIndicates the validity of the provided case temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.8
oaCrntPMLaser1TempValueThe optical amplifier laser 1 temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.9
oaCrntPMLaser1TempTimeStampThe date and time stamp of the laser 1 temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.10
oaCrntPMLaser1TempValidityIndicates the validity of the provided laser 1 temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.11
oaCrntPMLaser2TempValueThe optical amplifier laser 2 temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.12
oaCrntPMLaser2TempTimeStampThe date and time stamp of the laser 2 temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.13
oaCrntPMLaser2TempValidityIndicates the validity of the provided laser 2 temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.14
oaCrntPMOPRValueThe optical power received on the input of the amplifer.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.15
oaCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.16
oaCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.17
oaCrntPMSSIOPRValueThe optical power received on the input of the second stage of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.18
oaCrntPMSSIOPRTimeStampThe date and time stamp of the second stage input optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.19
oaCrntPMSSIOPRValidityIndicates the validity of the provided second stage input optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.20
oaCrntPMOPTValueThe optical power transmitted at the output of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.21
oaCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.22
oaCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.23
oaCrntPMMSInsLossValueThe mid-stage insertion loss.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.24
oaCrntPMMSInsLossTimeStampThe date and time stamp of the mid-stage insertion loss value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.25
oaCrntPMMSInsLossValidityIndicates the validity of the provided mid-stage insertion loss value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.26
oaCrntPMEffectiveGainValueThe effective gain of the optical amplifier. This reading is compensated for amplified spontaneous emissions.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.27
oaCrntPMEffectiveGainTimeStampThe date and time stamp of the effective gain value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.28
oaCrntPMEffectiveGainValidityIndicates the validity of the provided effective gain value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.29
oaCrntPMFSOOPTValueThe optical power transmitted at the output of the first stage of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.30
oaCrntPMFSOOPTTimeStampThe date and time stamp of the first stage output optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.31
oaCrntPMFSOOPTValidityIndicates the validity of the provided first stage output optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.32
oaCrntPMLaser1CurrentValueThe optical amplifier laser 1 current.ro
FixedX10 UNITS "mAmp/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.33
oaCrntPMLaser1CurrentTimeStampThe date and time stamp of the laser 1 current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.34
oaCrntPMLaser1CurrentValidityIndicates the validity of the provided laser 1 current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.35
oaCrntPMLaser2CurrentValueThe optical amplifier laser 2 current.ro
FixedX10 UNITS "mAmp/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.36
oaCrntPMLaser2CurrentTimeStampThe date and time stamp of the laser 2 current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.37
oaCrntPMLaser2CurrentValidityIndicates the validity of the provided laser 2 current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.38
oaCrntPMLaser1PowerValueThe optical amplifier laser 1 power.ro
FixedX10 UNITS "mWatts/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.39
oaCrntPMLaser1PowerTimeStampThe date and time stamp of the laser 1 power value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.40
oaCrntPMLaser1PowerValidityIndicates the validity of the provided laser 1 power value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.41
oaCrntPMLaser2PowerValueThe optical amplifier laser 2 power.ro
FixedX10 UNITS "mWatts/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.42
oaCrntPMLaser2PowerTimeStampThe date and time stamp of the laser 2 power value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.43
oaCrntPMLaser2PowerValidityIndicates the validity of the provided laser 2 power value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.44
oaCrntPMOBRValueThe back reflected optical power measured at the output of the second stage of the optical amplifier.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.45
oaCrntPMOBRTimeStampThe date and time stamp of the optical back reflection value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.46
oaCrntPMOBRValidityIndicates the validity of the provided optical back reflection value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.47
oaCrntPMVOAValueThe variable optical attenuation of the amplifier.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.1.1.48
oaCrntPMVOATimeStampThe date and time stamp of the variable optical attenuation value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.1.1.49
oaCrntPMVOAValidityIndicates the validity of the provided variable optical attenuation value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.1.1.50
oaHistPMTableA table of historical performance monitoring statistics collected for the optical amplifier facilities on the NE.
SEQUENCE OF OaHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.2
oaHistPMEntryThe row entry object of the optical amplifier historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given optical amplifier.
OaHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.2.1
oaHistPMOaTypeIdxThe type of the optical amplifier targeted for PM retrieval.
OaType
.1.3.6.1.4.1.18070.2.2.1.6.2.1.1
oaHistPMShelfIdxThe number of the shelf on which the amplifier targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.2
oaHistPMSlotIdxThe number of the slot within which the optical amplifier targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.2.1.3
oaHistPMOaIdxThe number of the amplifier port on the circuit pack targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.2.1.4
oaHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.2.1.5
oaHistPMIntervalIdxThe specific PM bin number. The range is 1..96 for 15-minute bins, and for 1-day historical bins, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.2.1.6
oaHistPMCaseTempValueThe optical amplifier case temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.7
oaHistPMCaseTempTimeStampThe date and time stamp of the case temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.8
oaHistPMCaseTempValidityIndicates the validity of the provided case temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.9
oaHistPMLaser1TempValueThe optical amplifier laser 1 temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.10
oaHistPMLaser1TempTimeStampThe date and time stamp of the laser 1 temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.11
oaHistPMLaser1TempValidityIndicates the validity of the provided laser 1 temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.12
oaHistPMLaser2TempValueThe optical amplifier laser 2 temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.13
oaHistPMLaser2TempTimeStampThe date and time stamp of the laser 2 temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.14
oaHistPMLaser2TempValidityIndicates the validity of the provided laser 2 temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.15
oaHistPMOPRValueThe optical power received on the input of the amplifer.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.16
oaHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.17
oaHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.18
oaHistPMSSIOPRValueThe optical power received on the input of the second stage of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.19
oaHistPMSSIOPRTimeStampThe date and time stamp of the second stage input optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.20
oaHistPMSSIOPRValidityIndicates the validity of the provided second stage input optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.21
oaHistPMOPTValueThe optical power transmitted at the output of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.22
oaHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.23
oaHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.24
oaHistPMMSInsLossValueThe mid-stage insertion loss.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.25
oaHistPMMSInsLossTimeStampThe date and time stamp of the mid-stage insertion loss value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.26
oaHistPMMSInsLossValidityIndicates the validity of the provided mid-stage insertion loss value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.27
oaHistPMEffectiveGainValueThe effective gain of the optical amplifier. This reading is compensated for amplified spontaneous emissions.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.28
oaHistPMEffectiveGainTimeStampThe date and time stamp of the effective gain value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.29
oaHistPMEffectiveGainValidityIndicates the validity of the provided effective gain value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.30
oaHistPMFSOOPTValueThe optical power transmitted at the output of the first stage of the amplifier.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.31
oaHistPMFSOOPTTimeStampThe date and time stamp of the first stage output optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.32
oaHistPMFSOOPTValidityIndicates the validity of the provided first stage output optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.33
oaHistPMLaser1CurrentValueThe optical amplifier laser 1 current.ro
FixedX10 UNITS "mAmp/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.34
oaHistPMLaser1CurrentTimeStampThe date and time stamp of the laser 1 current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.35
oaHistPMLaser1CurrentValidityIndicates the validity of the provided laser 1 current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.36
oaHistPMLaser2CurrentValueThe optical amplifier laser 2 current.ro
FixedX10 UNITS "mAmp/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.37
oaHistPMLaser2CurrentTimeStampThe date and time stamp of the laser 2 current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.38
oaHistPMLaser2CurrentValidityIndicates the validity of the provided laser 2 current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.39
oaHistPMLaser1PowerValueThe optical amplifier laser 1 power.ro
FixedX10 UNITS "mWatts/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.40
oaHistPMLaser1PowerTimeStampThe date and time stamp of the laser 1 power value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.41
oaHistPMLaser1PowerValidityIndicates the validity of the provided laser 1 power value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.42
oaHistPMLaser2PowerValueThe optical amplifier laser 2 power.ro
FixedX10 UNITS "mWatts/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.43
oaHistPMLaser2PowerTimeStampThe date and time stamp of the laser 2 power value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.44
oaHistPMLaser2PowerValidityIndicates the validity of the provided laser 2 power value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.45
oaHistPMOBRValueThe back reflected optical power measured at the output of the second stage of the optical amplifier.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.46
oaHistPMOBRTimeStampThe date and time stamp of the optical back reflection value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.47
oaHistPMOBRValidityIndicates the validity of the provided optical back reflection value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.48
oaHistPMVOAValueThe variable optical attenuation of the amplifier.ro
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.2.1.49
oaHistPMVOATimeStampThe date and time stamp of the variable optical attenuation value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.2.1.50
oaHistPMVOAValidityIndicates the validity of the provided variable optical attenuation value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.2.1.51
xcvrCrntPMTableA table of current performance monitoring statistics collected for the optical transceiver facilities on the NE.
SEQUENCE OF XcvrCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.3
xcvrCrntPMEntryThe row entry object of the optical transceiver current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given optical transceiver.
XcvrCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.3.1
xcvrCrntPMTypeIdxThe type of the optical transceiver targeted for PMs.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.6.3.1.1
xcvrCrntPMShelfIdxThe shelf number on which the optical transceiver targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.2
xcvrCrntPMSlotIdxThe slot number on which the optical transceiver targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.3.1.3
xcvrCrntPMIdxThe optical transceiver port number on the circuit pack that is targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.3.1.4
xcvrCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.3.1.5
xcvrCrntPMOPRValueThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.6
xcvrCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.7
xcvrCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.8
xcvrCrntPMOPTValueThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.9
xcvrCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.10
xcvrCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.11
xcvrCrntPMTempValueThe optical transceiver temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.12
xcvrCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.13
xcvrCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.14
xcvrCrntPMSupplyVoltageValueThe transceiver supply voltage.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.15
xcvrCrntPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.16
xcvrCrntPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.17
xcvrCrntPMLBCValueThe transceiver laser bias current.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.18
xcvrCrntPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.19
xcvrCrntPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.20
xcvrCrntPMCVSValueThe count of coding violations at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.21
xcvrCrntPMCVSTimeStampThe date and time stamp of the section layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.22
xcvrCrntPMCVSValidityIndicates the validity of the provided section layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.23
xcvrCrntPMESSValueThe count of errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.24
xcvrCrntPMESSTimeStampThe date and time stamp of the section layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.25
xcvrCrntPMESSValidityIndicates the validity of the provided section layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.26
xcvrCrntPMSESSValueThe count of severely errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.27
xcvrCrntPMSESSTimeStampThe date and time stamp of the section layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.28
xcvrCrntPMSESSValidityIndicates the validity of the provided section layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.29
xcvrCrntPMSEFSSValueThe count of severely errored framing seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.30
xcvrCrntPMSEFSSTimeStampThe date and time stamp of the section layer severely errored framing seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.31
xcvrCrntPMSEFSSValidityIndicates the validity of the provided section layer severely errored framing seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.32
xcvrCrntPMRSEBValueThe count of regenerator section errored blocks. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.33
xcvrCrntPMRSEBTimeStampThe date and time stamp of the regenerator section errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.34
xcvrCrntPMRSEBValidityIndicates the validity of the provided regenerator section errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.35
xcvrCrntPMRSBBEValueThe count of regenerator section background block errors. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.36
xcvrCrntPMRSBBETimeStampThe date and time stamp of the regenerator section background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.37
xcvrCrntPMRSBBEValidityIndicates the validity of the provided regenerator section background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.38
xcvrCrntPMRSESValueThe count of regenerator section errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.39
xcvrCrntPMRSESTimeStampThe date and time stamp of the regenerator section errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.40
xcvrCrntPMRSESValidityIndicates the validity of the provided regenerator section errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.41
xcvrCrntPMRSSESValueThe count of regenerator section severely errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.42
xcvrCrntPMRSSESTimeStampThe date and time stamp of the regenerator section severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.43
xcvrCrntPMRSSESValidityIndicates the validity of the provided regenerator section severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.44
xcvrCrntPMRSOFSValueThe count of regenerator section out-of-frame seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.45
xcvrCrntPMRSOFSTimeStampThe date and time stamp of the regenerator section out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.46
xcvrCrntPMRSOFSValidityIndicates the validity of the provided regenerator section out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.47
xcvrCrntPMCVValueThe count of coding violations. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.48
xcvrCrntPMCVTimeStampThe date and time stamp of the coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.49
xcvrCrntPMCVValidityIndicates the validity of the provided coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.50
xcvrCrntPMESValueThe count of errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.51
xcvrCrntPMESTimeStampThe date and time stamp of the errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.52
xcvrCrntPMESValidityIndicates the validity of the provided errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.53
xcvrCrntPMSESValueThe count of severely errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.54
xcvrCrntPMSESTimeStampThe date and time stamp of the severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.55
xcvrCrntPMSESValidityIndicates the validity of the provided severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.56
xcvrCrntPMINVBLKValueThe count of invalid blocks. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.57
xcvrCrntPMINVBLKTimeStampThe date and time stamp of the invalid blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.58
xcvrCrntPMINVBLKValidityIndicates the validity of the provided invalid blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.59
xcvrCrntPMNBITCRValueThe count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.60
xcvrCrntPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.61
xcvrCrntPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.62
xcvrCrntPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.63
xcvrCrntPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.64
xcvrCrntPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.65
xcvrCrntPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.66
xcvrCrntPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.67
xcvrCrntPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.68
xcvrCrntPMTBYCRXValueThe total number of bytes of data (including those in bad frames) received (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.69
xcvrCrntPMTBYCRXTimeStampThe date and time stamp of the received bytes count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.70
xcvrCrntPMTBYCRXValidityIndicates the validity of the provided received bytes count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.71
xcvrCrntPMTBYCRXInitializeUsed to initialize the value of the xcvrCrntPMTBYCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.72
xcvrCrntPMTFRCRXValueThe total number of received frames (incl. bad frames, broadcast frames, and multicast frames received). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.73
xcvrCrntPMTFRCRXTimeStampThe date and time stamp of the total received frames count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.74
xcvrCrntPMTFRCRXValidityIndicates the validity of the provided received frames count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.75
xcvrCrntPMTFRCRXInitializeUsed to initialize the value of the xcvrCrntPMTFRCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.76
xcvrCrntPMBCSTValueThe total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.77
xcvrCrntPMBCSTTimeStampThe date and time stamp of the broadcast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.78
xcvrCrntPMBCSTValidityIndicates the validity of the provided broadcast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.79
xcvrCrntPMBCSTInitializeUsed to initialize the value of the xcvrCrntPMBCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.80
xcvrCrntPMMCSTValueThe total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.81
xcvrCrntPMMCSTTimeStampThe date and time stamp of the multicast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.82
xcvrCrntPMMCSTValidityIndicates the validity of the provided multicast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.83
xcvrCrntPMMCSTInitializeUsed to initialize the value of the xcvrCrntPMMCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.84
xcvrCrntPMSIZE64ValueThe total number of 64 byte frames received (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.85
xcvrCrntPMSIZE64TimeStampThe date and time stamp of the count of 64-byte packets received.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.86
xcvrCrntPMSIZE64ValidityIndicates the validity of the provided count of 64-byte packets packets received.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.87
xcvrCrntPMSIZE64InitializeUsed to initialize the value of the xcvrCrntPMSIZE64Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.88
xcvrCrntPMSIZE65To127ValueThe total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.89
xcvrCrntPMSIZE65To127TimeStampThe date and time stamp of the count of packets between 65 and 127 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.90
xcvrCrntPMSIZE65To127ValidityIndicates the validity of the provided count of packets between 65 and 127 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.91
xcvrCrntPMSIZE65To127InitializeUsed to initialize the value of the xcvrCrntPMSIZE65To127Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.92
xcvrCrntPMSIZE128To255ValueThe total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.93
xcvrCrntPMSIZE128To255TimeStampThe date and time stamp of the count of packets between 128 and 255 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.94
xcvrCrntPMSIZE128To255ValidityIndicates the validity of the provided count of packets between 128 and 255 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.95
xcvrCrntPMSIZE128To255InitializeUsed to initialize the value of the xcvrCrntPMSIZE128To255Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.96
xcvrCrntPMSIZE256To511ValueThe total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.97
xcvrCrntPMSIZE256To511TimeStampThe date and time stamp of the count of packets between 256 and 511 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.98
xcvrCrntPMSIZE256To511ValidityIndicates the validity of the provided count of packets between 256 and 511 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.99
xcvrCrntPMSIZE256To511InitializeUsed to initialize the value of the xcvrCrntPMSIZE256To511Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.100
xcvrCrntPMSIZE512To1023ValueThe total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.101
xcvrCrntPMSIZE512To1023TimeStampThe date and time stamp of the count of packets between 512 and 1023 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.102
xcvrCrntPMSIZE512To1023ValidityIndicates the validity of the provided count of packets between 512 and 1023 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.103
xcvrCrntPMSIZE512To1023InitializeUsed to initialize the value of the xcvrCrntPMSIZE512To1023Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.104
xcvrCrntPMSIZE1024To1518ValueThe total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.105
xcvrCrntPMSIZE1024To1518TimeStampThe date and time stamp of the count of packets between 1024 and 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.106
xcvrCrntPMSIZE1024To1518ValidityIndicates the validity of the provided count of packets between 1024 and 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.107
xcvrCrntPMSIZE1024To1518InitializeUsed to initialize the value of the xcvrCrntPMSIZE1024To1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.108
xcvrCrntPMSIZEOver1518ValueThe total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.109
xcvrCrntPMSIZEOver1518TimeStampThe date and time stamp of the count of packets over 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.110
xcvrCrntPMSIZEOver1518ValidityIndicates the validity of the provided count of packets over 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.111
xcvrCrntPMSIZEOver1518InitializeUsed to initialize the value of the xcvrCrntPMSIZEOver1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.112
xcvrCrntPMFCSEValueThe count of packets that had a valid length but had either a Frame Check Sequence (FCS) or a bad FCS with a non-integral number of octets (Alignment Error) . This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.113
xcvrCrntPMFCSETimeStampThe date and time stamp of the count of packets with bad FCS or alignment error.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.114
xcvrCrntPMFCSEValidityIndicates the validity of the provided count of packets with bad FCS or alignment error.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.115
xcvrCrntPMFRDRValueThe total number of dropped frames due to lack of resources or otherwise. Note that this number is not necessarily the number of frames dropped; it is just the number of times that it could be detected. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.116
xcvrCrntPMFRDRTimeStampThe date and time stamp of the count of dropped packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.117
xcvrCrntPMFRDRValidityIndicates the validity of the provided count of dropped packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.118
xcvrCrntPMUSIZEValueThe total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.119
xcvrCrntPMUSIZETimeStampThe date and time stamp of the count of undersized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.120
xcvrCrntPMUSIZEValidityIndicates the validity of the provided count of undersized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.121
xcvrCrntPMOSIZEValueThe total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.122
xcvrCrntPMOSIZETimeStampThe date and time stamp of the count of oversized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.123
xcvrCrntPMOSIZEValidityIndicates the validity of the provided count of oversized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.124
xcvrCrntPMFRGTValueThe total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.125
xcvrCrntPMFRGTTimeStampThe date and time stamp of the count of received packet fragments.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.126
xcvrCrntPMFRGTValidityIndicates the validity of the provided count of received packet fragments.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.127
xcvrCrntPMJABRValueThe total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.128
xcvrCrntPMJABRTimeStampThe date and time stamp of the count of received jabbers.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.129
xcvrCrntPMJABRValidityIndicates the validity of the provided count of received jabbers.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.130
xcvrCrntPMOTUEBValueThe count of OTN digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.131
xcvrCrntPMOTUEBTimeStampThe date and time stamp of the OTN digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.132
xcvrCrntPMOTUEBValidityIndicates the validity of the provided OTN digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.133
xcvrCrntPMOTUBBEValueThe count of OTN digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.134
xcvrCrntPMOTUBBETimeStampThe date and time stamp of the OTN digital wrapper layer background block errors.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.135
xcvrCrntPMOTUBBEValidityIndicates the validity of the provided OTN digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.136
xcvrCrntPMOTUESValueThe count of errored seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.137
xcvrCrntPMOTUESTimeStampThe date and time stamp of the OTN digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.138
xcvrCrntPMOTUESValidityIndicates the validity of the provided OTN digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.139
xcvrCrntPMOTUSESValueThe count of severely errored seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.140
xcvrCrntPMOTUSESTimeStampThe date and time stamp of the OTN digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.141
xcvrCrntPMOTUSESValidityIndicates the validity of the provided OTN digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.142
xcvrCrntPMOTUOFSValueThe count of Out-Of-Frame seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.143
xcvrCrntPMOTUOFSTimeStampThe date and time stamp of the OTN digital wrapper layer Out-Of-Frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.144
xcvrCrntPMOTUOFSValidityIndicates the validity of the provided OTN digital wrapper layer Out-of-Frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.145
xcvrCrntPMSupplyVoltage2ValueA second supply voltage value on the transceiver.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.146
xcvrCrntPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.147
xcvrCrntPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.148
xcvrCrntPMCVSInitializeUsed to initialize the value of the xcvrCrntPMCVSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.149
xcvrCrntPMESSInitializeUsed to initialize the value of the xcvrCrntPMESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.150
xcvrCrntPMSESSInitializeUsed to initialize the value of the xcvrCrntPMSESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.151
xcvrCrntPMSEFSSInitializeUsed to initialize the value of the xcvrCrntPMSEFSSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.152
xcvrCrntPMRSEBInitializeUsed to initialize the value of the xcvrCrntPMRSEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.153
xcvrCrntPMRSBBEInitializeUsed to initialize the value of the xcvrCrntPMRSBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.154
xcvrCrntPMRSESInitializeUsed to initialize the value of the xcvrCrntPMRSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.155
xcvrCrntPMRSSESInitializeUsed to initialize the value of the xcvrCrntPMRSSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.156
xcvrCrntPMRSOFSInitializeUsed to initialize the value of the xcvrCrntPMRSOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.157
xcvrCrntPMCVInitializeUsed to initialize the value of the xcvrCrntPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.158
xcvrCrntPMESInitializeUsed to initialize the value of the xcvrCrntPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.159
xcvrCrntPMSESInitializeUsed to initialize the value of the xcvrCrntPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.160
xcvrCrntPMINVBLKInitializeUsed to initialize the value of the xcvrCrntPMINVBLKValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.161
xcvrCrntPMNBITCRInitializeUsed to initialize the value of the xcvrCrntPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.162
xcvrCrntPMNBYTCRInitializeUsed to initialize the value of the xcvrCrntPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.163
xcvrCrntPMUNCRCDWInitializeUsed to initialize the value of the xcvrCrntPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.164
xcvrCrntPMFCSEInitializeUsed to initialize the value of the xcvrCrntPMFCSEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.165
xcvrCrntPMFRDRInitializeUsed to initialize the value of the xcvrCrntPMFRDRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.166
xcvrCrntPMUSIZEInitializeUsed to initialize the value of the xcvrCrntPMUSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.167
xcvrCrntPMOSIZEInitializeUsed to initialize the value of the xcvrCrntPMOSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.168
xcvrCrntPMFRGTInitializeUsed to initialize the value of the xcvrCrntPMFRGTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.169
xcvrCrntPMJABRInitializeUsed to initialize the value of the xcvrCrntPMJABRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.170
xcvrCrntPMOTUEBInitializeUsed to initialize the value of the xcvrCrntPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.171
xcvrCrntPMOTUBBEInitializeUsed to initialize the value of the xcvrCrntPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.172
xcvrCrntPMOTUESInitializeUsed to initialize the value of the xcvrCrntPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.173
xcvrCrntPMOTUSESInitializeUsed to initialize the value of the xcvrCrntPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.174
xcvrCrntPMOTUOFSInitializeUsed to initialize the value of the xcvrCrntPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.175
xcvrCrntPMUASSValueThe count of unavailable seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.176
xcvrCrntPMUASSTimeStampThe date and time stamp of the section layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.177
xcvrCrntPMUASSValidityIndicates the validity of the provided section layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.178
xcvrCrntPMUASSInitializeUsed to initialize the value of the xcvrCrntPMUASSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.179
xcvrCrntPMRSUASValueThe count of regenerator section unavailable seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.180
xcvrCrntPMRSUASTimeStampThe date and time stamp of the regenerator section unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.181
xcvrCrntPMRSUASValidityIndicates the validity of the provided regenerator section unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.182
xcvrCrntPMRSUASInitializeUsed to initialize the value of the xcvrCrntPMRSUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.183
xcvrCrntPMUASValueThe count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.184
xcvrCrntPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.185
xcvrCrntPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.186
xcvrCrntPMUASInitializeUsed to initialize the value of the xcvrCrntPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.187
xcvrCrntPMOTUUASValueThe count of unavailable seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.3.1.188
xcvrCrntPMOTUUASTimeStampThe date and time stamp of the OTN digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.189
xcvrCrntPMOTUUASValidityIndicates the validity of the provided OTN digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.190
xcvrCrntPMOTUUASInitializeUsed to initialize the value of the xcvrCrntPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.191
xcvrCrntPMOTNBERValueThe instantaneous BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.192
xcvrCrntPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.193
xcvrCrntPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.194
xcvrCrntPMOTNBERInitializeUsed to initialize the value of the xcvrCrntPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.195
xcvrCrntPMOTNAVGBERValueThe average/interval BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.196
xcvrCrntPMOTNAVGBERTimeStampThe date and time stamp of the average/interval BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.197
xcvrCrntPMOTNAVGBERValidityIndicates the validity of the provided average/interval BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.198
xcvrCrntPMOTNAVGBERInitializeUsed to initialize the value of the xcvrCrntPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.199
xcvrCrntPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.200
xcvrCrntPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.201
xcvrCrntPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.202
xcvrCrntPMNBITCR64BitInitializeUsed to initialize the value of the xcvrCrntPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.203
xcvrCrntPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.3.1.204
xcvrCrntPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.205
xcvrCrntPMNBYTCR64BitValidityIndicates the validity of the provided 64-bit number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.206
xcvrCrntPMNBYTCR64BitInitializeUsed to initialize the value of the xcvrCrntPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.207
xcvrCrntPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.208
xcvrCrntPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.209
xcvrCrntPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.210
xcvrCrntPMOPRMinInitializeUsed to initialize the value of the xcvrCrntPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.211
xcvrCrntPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.212
xcvrCrntPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.213
xcvrCrntPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.214
xcvrCrntPMOPRMaxInitializeUsed to initialize the value of the xcvrCrntPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.215
xcvrCrntPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.216
xcvrCrntPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.217
xcvrCrntPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.218
xcvrCrntPMOPRAvgInitializeUsed to initialize the value of the xcvrCrntPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.219
xcvrCrntPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.220
xcvrCrntPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.221
xcvrCrntPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.222
xcvrCrntPMOPTMinInitializeUsed to initialize the value of the xcvrCrntPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.223
xcvrCrntPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.224
xcvrCrntPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.225
xcvrCrntPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.226
xcvrCrntPMOPTMaxInitializeUsed to initialize the value of the xcvrCrntPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.227
xcvrCrntPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.3.1.228
xcvrCrntPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.3.1.229
xcvrCrntPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.3.1.230
xcvrCrntPMOPTAvgInitializeUsed to initialize the value of the xcvrCrntPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.3.1.231
xcvrHistPMTableA table of historical performance monitoring statistics collected for the optical transceiver facilities on the NE.
SEQUENCE OF XcvrHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.4
xcvrHistPMEntryThe row entry object of the optical transceiver historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given optical transceiver.
XcvrHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.4.1
xcvrHistPMTypeIdxThe type of the optical transceiver targeted for PMs.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.6.4.1.1
xcvrHistPMShelfIdxThe number of the shelf on which the optical transceiver targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.2
xcvrHistPMSlotIdxThe number of the slot within which the optical transceiver targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.4.1.3
xcvrHistPMIdxThe number of the transceiver port targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.4.1.4
xcvrHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.4.1.5
xcvrHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.4.1.6
xcvrHistPMOPRValueThe optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.7
xcvrHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.8
xcvrHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.9
xcvrHistPMOPTValueThe optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.10
xcvrHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.11
xcvrHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.12
xcvrHistPMTempValueThe optical transceiver temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.13
xcvrHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.14
xcvrHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.15
xcvrHistPMSupplyVoltageValueThe transceiver supply voltage.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.16
xcvrHistPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.17
xcvrHistPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.18
xcvrHistPMLBCValueThe transceiver laser bias current.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.19
xcvrHistPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.20
xcvrHistPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.21
xcvrHistPMCVSValueThe count of coding violations at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.22
xcvrHistPMCVSTimeStampThe date and time stamp of the section layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.23
xcvrHistPMCVSValidityIndicates the validity of the provided section layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.24
xcvrHistPMESSValueThe count of errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.25
xcvrHistPMESSTimeStampThe date and time stamp of the section layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.26
xcvrHistPMESSValidityIndicates the validity of the provided section layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.27
xcvrHistPMSESSValueThe count of severely errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.28
xcvrHistPMSESSTimeStampThe date and time stamp of the section layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.29
xcvrHistPMSESSValidityIndicates the validity of the provided section layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.30
xcvrHistPMSEFSSValueThe count of severely errored framing seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.31
xcvrHistPMSEFSSTimeStampThe date and time stamp of the section layer severely errored framing seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.32
xcvrHistPMSEFSSValidityIndicates the validity of the provided section layer severely errored framing seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.33
xcvrHistPMRSEBValueThe count of regenerator section errored blocks. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.34
xcvrHistPMRSEBTimeStampThe date and time stamp of the regenerator section errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.35
xcvrHistPMRSEBValidityIndicates the validity of the provided regenerator section errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.36
xcvrHistPMRSBBEValueThe count of regenerator section background block errors. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.37
xcvrHistPMRSBBETimeStampThe date and time stamp of the regenerator section background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.38
xcvrHistPMRSBBEValidityIndicates the validity of the provided regenerator section background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.39
xcvrHistPMRSESValueThe count of regenerator section errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.40
xcvrHistPMRSESTimeStampThe date and time stamp of the regenerator section errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.41
xcvrHistPMRSESValidityIndicates the validity of the provided regenerator section errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.42
xcvrHistPMRSSESValueThe count of regenerator section severely errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.43
xcvrHistPMRSSESTimeStampThe date and time stamp of the regenerator section severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.44
xcvrHistPMRSSESValidityIndicates the validity of the provided regenerator section severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.45
xcvrHistPMRSOFSValueThe count of regenerator section out-of-frame seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.46
xcvrHistPMRSOFSTimeStampThe date and time stamp of the regenerator section out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.47
xcvrHistPMRSOFSValidityIndicates the validity of the provided regenerator section out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.48
xcvrHistPMCVValueThe count of coding violations. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.49
xcvrHistPMCVTimeStampThe date and time stamp of the coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.50
xcvrHistPMCVValidityIndicates the validity of the provided coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.51
xcvrHistPMESValueThe count of errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.52
xcvrHistPMESTimeStampThe date and time stamp of the errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.53
xcvrHistPMESValidityIndicates the validity of the provided errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.54
xcvrHistPMSESValueThe count of severely errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.55
xcvrHistPMSESTimeStampThe date and time stamp of the severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.56
xcvrHistPMSESValidityIndicates the validity of the provided severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.57
xcvrHistPMINVBLKValueThe count of invalid blocks. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.58
xcvrHistPMINVBLKTimeStampThe date and time stamp of the invalid blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.59
xcvrHistPMINVBLKValidityIndicates the validity of the provided invalid blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.60
xcvrHistPMNBITCRValueThe count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.61
xcvrHistPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.62
xcvrHistPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.63
xcvrHistPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.64
xcvrHistPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.65
xcvrHistPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.66
xcvrHistPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.67
xcvrHistPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.68
xcvrHistPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.69
xcvrHistPMTBYCRXValueThe total number of bytes of data (including those in bad frames) received (excluding framing bits but including FCS bytes). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.70
xcvrHistPMTBYCRXTimeStampThe date and time stamp of the received bytes count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.71
xcvrHistPMTBYCRXValidityIndicates the validity of the provided received bytes count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.72
xcvrHistPMTBYCRXInitializeUsed to initialize the value of the xcvrHistPMTBYCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.73
xcvrHistPMTFRCRXValueThe total number of received frames (incl. bad frames, broadcast frames, and multicast frames received). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.74
xcvrHistPMTFRCRXTimeStampThe date and time stamp of the received frames count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.75
xcvrHistPMTFRCRXValidityIndicates the validity of the provided received frames count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.76
xcvrHistPMTFRCRXInitializeUsed to initialize the value of the xcvrHistPMTFRCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.77
xcvrHistPMBCSTValueThe total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.78
xcvrHistPMBCSTTimeStampThe date and time stamp of the broadcast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.79
xcvrHistPMBCSTValidityIndicates the validity of the provided broadcast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.80
xcvrHistPMBCSTInitializeUsed to initialize the value of the xcvrHistPMBCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.81
xcvrHistPMMCSTValueThe total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.82
xcvrHistPMMCSTTimeStampThe date and time stamp of the multicast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.83
xcvrHistPMMCSTValidityIndicates the validity of the provided multicast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.84
xcvrHistPMMCSTInitializeUsed to initialize the value of the xcvrHistPMMCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.85
xcvrHistPMSIZE64ValueThe total number of 64 byte frames received (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.86
xcvrHistPMSIZE64TimeStampThe date and time stamp of the count of 64-byte packets received.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.87
xcvrHistPMSIZE64ValidityIndicates the validity of the provided count of 64-byte packets packets received.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.88
xcvrHistPMSIZE64InitializeUsed to initialize the value of the xcvrHistPMSIZE64Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.89
xcvrHistPMSIZE65To127ValueThe total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.90
xcvrHistPMSIZE65To127TimeStampThe date and time stamp of the count of packets between 65 and 127 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.91
xcvrHistPMSIZE65To127ValidityIndicates the validity of the provided count of packets between 65 and 127 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.92
xcvrHistPMSIZE65To127InitializeUsed to initialize the value of the xcvrHistPMSIZE65To127Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.93
xcvrHistPMSIZE128To255ValueThe total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.94
xcvrHistPMSIZE128To255TimeStampThe date and time stamp of the count of packets between 128 and 255 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.95
xcvrHistPMSIZE128To255ValidityIndicates the validity of the provided count of packets between 128 and 255 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.96
xcvrHistPMSIZE128To255InitializeUsed to initialize the value of the xcvrHistPMSIZE128To255Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.97
xcvrHistPMSIZE256To511ValueThe total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.98
xcvrHistPMSIZE256To511TimeStampThe date and time stamp of the count of packets between 256 and 511 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.99
xcvrHistPMSIZE256To511ValidityIndicates the validity of the provided count of packets between 256 and 511 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.100
xcvrHistPMSIZE256To511InitializeUsed to initialize the value of the xcvrHistPMSIZE256To511Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.101
xcvrHistPMSIZE512To1023ValueThe total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.102
xcvrHistPMSIZE512To1023TimeStampThe date and time stamp of the count of packets between 512 and 1023 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.103
xcvrHistPMSIZE512To1023ValidityIndicates the validity of the provided count of packets between 512 and 1023 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.104
xcvrHistPMSIZE512To1023InitializeUsed to initialize the value of the xcvrHistPMSIZE512To1023Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.105
xcvrHistPMSIZE1024To1518ValueThe total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.106
xcvrHistPMSIZE1024To1518TimeStampThe date and time stamp of the count of packets between 1024 and 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.107
xcvrHistPMSIZE1024To1518ValidityIndicates the validity of the provided count of packets between 1024 and 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.108
xcvrHistPMSIZE1024To1518InitializeUsed to initialize the value of the xcvrHistPMSIZE1024To1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.109
xcvrHistPMSIZEOver1518ValueThe total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.110
xcvrHistPMSIZEOver1518TimeStampThe date and time stamp of the count of packets over 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.111
xcvrHistPMSIZEOver1518ValidityIndicates the validity of the provided count of packets over 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.112
xcvrHistPMSIZEOver1518InitializeUsed to initialize the value of the xcvrHistPMSIZEOver1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.113
xcvrHistPMFCSEValueThe count of packets that had a valid length but had either a Frame Check Sequence (FCS) or a bad FCS with a non-integral number of octets (Alignment Error) . This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.114
xcvrHistPMFCSETimeStampThe date and time stamp of the count of packets with bad FCS or alignment error.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.115
xcvrHistPMFCSEValidityIndicates the validity of the provided count of packets with bad FCS or alignment error.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.116
xcvrHistPMFRDRValueThe total number of dropped frames due to lack of resources or otherwise. Note that this number is not necessarily the number of frames dropped; it is just the number of times that it could be detected. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.117
xcvrHistPMFRDRTimeStampThe date and time stamp of the count of dropped packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.118
xcvrHistPMFRDRValidityIndicates the validity of the provided count of dropped packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.119
xcvrHistPMUSIZEValueThe total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.120
xcvrHistPMUSIZETimeStampThe date and time stamp of the count of undersized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.121
xcvrHistPMUSIZEValidityIndicates the validity of the provided count of undersized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.122
xcvrHistPMOSIZEValueThe total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.123
xcvrHistPMOSIZETimeStampThe date and time stamp of the count of oversized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.124
xcvrHistPMOSIZEValidityIndicates the validity of the provided count of oversized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.125
xcvrHistPMFRGTValueThe total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.126
xcvrHistPMFRGTTimeStampThe date and time stamp of the count of received packet fragments.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.127
xcvrHistPMFRGTValidityIndicates the validity of the provided count of received packet fragments.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.128
xcvrHistPMJABRValueThe total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.129
xcvrHistPMJABRTimeStampThe date and time stamp of the count of received jabbers.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.130
xcvrHistPMJABRValidityIndicates the validity of the provided count of received jabbers.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.131
xcvrHistPMOTUEBValueThe count of OTN digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.132
xcvrHistPMOTUEBTimeStampThe date and time stamp of the OTN digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.133
xcvrHistPMOTUEBValidityIndicates the validity of the provided OTN digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.134
xcvrHistPMOTUBBEValueThe count of OTN digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.135
xcvrHistPMOTUBBETimeStampThe date and time stamp of the OTN digital wrapper layer background block errors.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.136
xcvrHistPMOTUBBEValidityIndicates the validity of the provided OTN digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.137
xcvrHistPMOTUESValueThe count of errored seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.138
xcvrHistPMOTUESTimeStampThe date and time stamp of the OTN digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.139
xcvrHistPMOTUESValidityIndicates the validity of the provided OTN digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.140
xcvrHistPMOTUSESValueThe count of severely errored seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.141
xcvrHistPMOTUSESTimeStampThe date and time stamp of the OTN digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.142
xcvrHistPMOTUSESValidityIndicates the validity of the provided OTN digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.143
xcvrHistPMOTUOFSValueThe count of Out-Of-Frame seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.144
xcvrHistPMOTUOFSTimeStampThe date and time stamp of the OTN digital wrapper layer Out-Of-Frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.145
xcvrHistPMOTUOFSValidityIndicates the validity of the provided OTN digital wrapper layer Out-of-Frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.146
xcvrHistPMSupplyVoltage2ValueA second supply voltage value on the transceiver.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.147
xcvrHistPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.148
xcvrHistPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.149
xcvrHistPMCVSInitializeUsed to initialize the value of the xcvrHistPMCVSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.150
xcvrHistPMESSInitializeUsed to initialize the value of the xcvrHistPMESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.151
xcvrHistPMSESSInitializeUsed to initialize the value of the xcvrHistPMSESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.152
xcvrHistPMSEFSSInitializeUsed to initialize the value of the xcvrHistPMSEFSSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.153
xcvrHistPMRSEBInitializeUsed to initialize the value of the xcvrHistPMRSEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.154
xcvrHistPMRSBBEInitializeUsed to initialize the value of the xcvrHistPMRSBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.155
xcvrHistPMRSESInitializeUsed to initialize the value of the xcvrHistPMRSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.156
xcvrHistPMRSSESInitializeUsed to initialize the value of the xcvrHistPMRSSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.157
xcvrHistPMRSOFSInitializeUsed to initialize the value of the xcvrHistPMRSOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.158
xcvrHistPMCVInitializeUsed to initialize the value of the xcvrHistPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.159
xcvrHistPMESInitializeUsed to initialize the value of the xcvrHistPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.160
xcvrHistPMSESInitializeUsed to initialize the value of the xcvrHistPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.161
xcvrHistPMINVBLKInitializeUsed to initialize the value of the xcvrHistPMINVBLKValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.162
xcvrHistPMNBITCRInitializeUsed to initialize the value of the xcvrHistPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.163
xcvrHistPMNBYTCRInitializeUsed to initialize the value of the xcvrHistPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.164
xcvrHistPMUNCRCDWInitializeUsed to initialize the value of the xcvrHistPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.165
xcvrHistPMFCSEInitializeUsed to initialize the value of the xcvrHistPMFCSEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.166
xcvrHistPMFRDRInitializeUsed to initialize the value of the xcvrHistPMFRDRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.167
xcvrHistPMUSIZEInitializeUsed to initialize the value of the xcvrHistPMUSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.168
xcvrHistPMOSIZEInitializeUsed to initialize the value of the xcvrHistPMOSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.169
xcvrHistPMFRGTInitializeUsed to initialize the value of the xcvrHistPMFRGTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.170
xcvrHistPMJABRInitializeUsed to initialize the value of the xcvrHistPMJABRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.171
xcvrHistPMOTUEBInitializeUsed to initialize the value of the xcvrHistPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.172
xcvrHistPMOTUBBEInitializeUsed to initialize the value of the xcvrHistPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.173
xcvrHistPMOTUESInitializeUsed to initialize the value of the xcvrHistPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.174
xcvrHistPMOTUSESInitializeUsed to initialize the value of the xcvrHistPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.175
xcvrHistPMOTUOFSInitializeUsed to initialize the value of the xcvrHistPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.176
xcvrHistPMUASSValueThe count of unavailable seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.177
xcvrHistPMUASSTimeStampThe date and time stamp of the section layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.178
xcvrHistPMUASSValidityIndicates the validity of the provided section layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.179
xcvrHistPMUASSInitializeUsed to initialize the value of the xcvrHistPMUASSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.180
xcvrHistPMRSUASValueThe count of regenerator section unavailable seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.181
xcvrHistPMRSUASTimeStampThe date and time stamp of the regenerator section unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.182
xcvrHistPMRSUASValidityIndicates the validity of the provided regenerator section unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.183
xcvrHistPMRSUASInitializeUsed to initialize the value of the xcvrHistPMRSUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.184
xcvrHistPMUASValueThe count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.185
xcvrHistPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.186
xcvrHistPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.187
xcvrHistPMUASInitializeUsed to initialize the value of the xcvrHistPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.188
xcvrHistPMOTUUASValueThe count of unavailable seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.4.1.189
xcvrHistPMOTUUASTimeStampThe date and time stamp of the OTN digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.190
xcvrHistPMOTUUASValidityIndicates the validity of the provided OTN digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.191
xcvrHistPMOTUUASInitializeUsed to initialize the value of the xcvrHistPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.192
xcvrHistPMOTNBERValueThe instantaneous BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.193
xcvrHistPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.194
xcvrHistPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.195
xcvrHistPMOTNBERInitializeUsed to initialize the value of the xcvrHistPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.196
xcvrHistPMOTNAVGBERValueThe interval/average BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.197
xcvrHistPMOTNAVGBERTimeStampThe date and time stamp of the interval/average BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.198
xcvrHistPMOTNAVGBERValidityIndicates the validity of the provided interval/average BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.199
xcvrHistPMOTNAVGBERInitializeUsed to initialize the value of the xcvrHistPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.200
xcvrHistPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.201
xcvrHistPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.202
xcvrHistPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.203
xcvrHistPMNBITCR64BitInitializeUsed to initialize the value of the xcvrHistPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.204
xcvrHistPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.4.1.205
xcvrHistPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.206
xcvrHistPMNBYTCR64BitValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.207
xcvrHistPMNBYTCR64BitInitializeUsed to initialize the value of the xcvrHistPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.208
xcvrHistPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.209
xcvrHistPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.210
xcvrHistPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.211
xcvrHistPMOPRMinInitializeUsed to initialize the value of the xcvrHistPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.212
xcvrHistPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.213
xcvrHistPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.214
xcvrHistPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.215
xcvrHistPMOPRMaxInitializeUsed to initialize the value of the xcvrHistPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.216
xcvrHistPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.217
xcvrHistPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.218
xcvrHistPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.219
xcvrHistPMOPRAvgInitializeUsed to initialize the value of the xcvrHistPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.220
xcvrHistPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.221
xcvrHistPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.222
xcvrHistPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.223
xcvrHistPMOPTMinInitializeUsed to initialize the value of the xcvrHistPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.224
xcvrHistPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.225
xcvrHistPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.226
xcvrHistPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.227
xcvrHistPMOPTMaxInitializeUsed to initialize the value of the xcvrHistPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.228
xcvrHistPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.4.1.229
xcvrHistPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.4.1.230
xcvrHistPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.4.1.231
xcvrHistPMOPTAvgInitializeUsed to initialize the value of the xcvrHistPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.4.1.232
xcvrPMThresholdTableA table of threshold levels for performance monitoring counter values on optical transceiver facilities, that are used in the generation of threshold crossing alerts.
SEQUENCE OF XcvrPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.5
xcvrPMThresholdEntryThe row entry object of the optical transceiver performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual optical transceiver.
XcvrPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.5.1
xcvrPMThresholdTypeIdxThe type of the optical transceiver targeted for PM thresholds.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.6.5.1.1
xcvrPMThresholdShelfIdxThe shelf number on which the optical transceiver targeted for PM thresholds is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.5.1.2
xcvrPMThresholdSlotIdxThe slot number on which the optical transceiver targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.5.1.3
xcvrPMThresholdIdxThe optical transceiver port number on the circuit pack that is targeted for PM thresholds.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.5.1.4
xcvrPMThresholdIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.5.1.5
xcvrPMThresholdCVSValueThe threshold for the count of coding violations at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.6
xcvrPMThresholdESSValueThe threshold for the count of errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.7
xcvrPMThresholdSESSValueThe threshold fro the count of severely errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.8
xcvrPMThresholdSEFSSValueThe threshold for the count of severely errored framing seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.9
xcvrPMThresholdRSEBValueThe threshold for the count of regenerator section errored blocks. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.10
xcvrPMThresholdRSBBEValueThe threshold for the count of regenerator section background block errors. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.11
xcvrPMThresholdRSESValueThe threshold for the count of regenerator section errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.12
xcvrPMThresholdRSSESValueThe threshold for the count of regenerator section severely errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.13
xcvrPMThresholdRSOFSValueThe threshold for the count of regenerator section out-of-frame seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.14
xcvrPMThresholdCVValueThe threshold for the count of coding violations. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.15
xcvrPMThresholdESValueThe threshold for the count of errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.16
xcvrPMThresholdSESValueThe threshold for the count of severely errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.17
xcvrPMThresholdINVBLKValueThe threshold for the count of invalid blocks. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.18
xcvrPMThresholdUNCRCDWValueThe threshold for the count of uncorrectable codewords. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.21
xcvrPMThresholdFCSEValueThe threshold for the count of FCSE packets. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.22
xcvrPMThresholdFRDRValueThe threshold for the count of dropped frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.23
xcvrPMThresholdUSIZEValueThe threshold for the count of undersized frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.24
xcvrPMThresholdOSIZEValueThe threshold for the count of oversized frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.25
xcvrPMThresholdFRGTValueThe threshold for the count of frame fragments. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.26
xcvrPMThresholdJABRValueThe threshold for the count of jabbers. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.27
xcvrPMThresholdOTUEBValueThe threshold for the count of errored blocks at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.28
xcvrPMThresholdOTUBBEValueThe threshold for the count of background block errors at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.29
xcvrPMThresholdOTUESValueThe threshold for the count of errored seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.30
xcvrPMThresholdOTUSESValueThe threshold for the count of severely errored seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.31
xcvrPMThresholdOTUOFSValueThe threshold for the count of Out-of-Frame seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.32
xcvrPMThresholdUASSValueThe threshold for the count of unavailable seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.33
xcvrPMThresholdRSUASValueThe threshold for the count of regenerator section unavailable seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.34
xcvrPMThresholdUASValueThe threshold for the count of unavailable seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.35
xcvrPMThresholdOTUUASValueThe threshold for the count of unavailable seconds at the OTN digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.5.1.36
amdCrntPMTableA table of current performance monitoring statistics collected for the ports of active multiplexer-demultiplexer circuit packs.obsolete
SEQUENCE OF AmdCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.6
amdCrntPMEntryThe row entry object of the active multiplexer-demultiplexer current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given AMD port.obsolete
AmdCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.6.1
amdCrntPMTypeIdxThe specific type of active multiplexer-demultiplexer circuit pack on which the facility targeted for PMs is provisioned.obsolete
AmdType
.1.3.6.1.4.1.18070.2.2.1.6.6.1.1
amdCrntPMShelfIdxThe number of the shelf on which the active multiplexer-demultiplexer facility targeted for PMs is provisioned.obsolete
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.6.1.2
amdCrntPMSlotIdxThe number of the slot within which the active multiplexer-demultiplexer facility targeted for PMs is provisioned.obsolete
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.6.1.3
amdCrntPMLineIdxThe number of the multiplexed wavelength line on the AMD circuit pack that is targeted for PMs.obsolete
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.6.1.4
amdCrntPMPortIdxIdentifies a specific port on the identified line of the AMD circuit pack that is targeted for PMs.obsolete
AmdPortType
.1.3.6.1.4.1.18070.2.2.1.6.6.1.5
amdCrntPMIntervalTypeIdxThe type of PM bin according to interval length.obsolete
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.6.1.6
amdCrntPMOPRValueThe optical power received on the input of the AMD port.roobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.6.1.7
amdCrntPMOPRTimeStampThe date and time stamp of the optical power received value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.6.1.8
amdCrntPMOPRValidityIndicates the validity of the provided optical power received value.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.6.1.9
amdCrntPMOPTValueThe optical power transmitted at the output of the AMD port.roobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.6.1.10
amdCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.6.1.11
amdCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.6.1.12
amdCrntPMVOAValueThe variable optical attenuation of the AMD port.roobsolete
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.6.1.13
amdCrntPMVOATimeStampThe date and time stamp of the variable optical attenuation value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.6.1.14
amdCrntPMVOAValidityIndicates the validity of the provided variable optical attenuation value.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.6.1.15
amdCrntPMLitChnValueThe number of muxed channels with light on the line port.roobsolete
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.6.1.16
amdCrntPMLitChnTimeStampThe date and time stamp of the number of lit channels value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.6.1.17
amdCrntPMLitChnValidityIndicates the validity of the provided number of lit channels value.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.6.1.18
amdHistPMTableA table of historical performance monitoring statistics collected for the ports of active multiplexer-demultiplexer circuit packs.obsolete
SEQUENCE OF AmdHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.7
amdHistPMEntryThe row entry object of the active multiplexer-demultiplexer historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given AMD port.obsolete
AmdHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.7.1
amdHistPMTypeIdxThe specific type of active multiplexer-demultiplexer circuit pack on which the facility targeted for PMs is provisioned.obsolete
AmdType
.1.3.6.1.4.1.18070.2.2.1.6.7.1.1
amdHistPMShelfIdxThe number of the shelf on which the active multiplexer-demultiplexer facility targeted for PMs is provisioned.obsolete
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.7.1.2
amdHistPMSlotIdxThe number of the slot within which the active multiplexer-demultiplexer facility targeted for PMs is provisioned.obsolete
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.7.1.3
amdHistPMLineIdxThe number of the multiplexed wavelength line on the AMD circuit pack that is targeted for PMs.obsolete
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.7.1.4
amdHistPMPortIdxIdentifies a specific port on the identified line of the AMD circuit pack that is targeted for PMs.obsolete
AmdPortType
.1.3.6.1.4.1.18070.2.2.1.6.7.1.5
amdHistPMIntervalTypeIdxThe type of PM bin according to interval length.obsolete
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.7.1.6
amdHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.obsolete
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.7.1.7
amdHistPMOPRValueThe optical power received on the input of the AMD port.roobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.7.1.8
amdHistPMOPRTimeStampThe date and time stamp of the optical power received value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.7.1.9
amdHistPMOPRValidityIndicates the validity of the provided optical power received value.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.7.1.10
amdHistPMOPTValueThe optical power transmitted at the output of the AMD port.roobsolete
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.7.1.11
amdHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.7.1.12
amdHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.7.1.13
amdHistPMVOAValueThe variable optical attenuation of the AMD port.roobsolete
FixedX10 UNITS "dB/10"
.1.3.6.1.4.1.18070.2.2.1.6.7.1.14
amdHistPMVOATimeStampThe date and time stamp of the variable optical attenuation value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.7.1.15
amdHistPMVOAValidityIndicates the validity of the provided variable optical attenuation valcue.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.7.1.16
amdHistPMLitChnValueThe number of muxed channels with light on the line port.roobsolete
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.7.1.17
amdHistPMLitChnTimeStampThe date and time stamp of the number of lit channels value.roobsolete
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.7.1.18
amdHistPMLitChnValidityIndicates the validity of the provided number of lit channels value.roobsolete
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.7.1.19
ocnCrntPMTableA table of current performance monitoring statistics collected for the SONET OC-N facilities on the NE.
SEQUENCE OF OcnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.8
ocnCrntPMEntryThe row entry object of the SONET OC-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given OC-N facility.
OcnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.8.1
ocnCrntPMTypeIdxThe type of OC-N facility targeted for PMs.
OcnType
.1.3.6.1.4.1.18070.2.2.1.6.8.1.1
ocnCrntPMShelfIdxThe number of the shelf on which the OC-N facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.2
ocnCrntPMSlotIdxThe number of the slot within which the OC-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.8.1.3
ocnCrntPMPortIdxThe number of the port on the circuit pack on which the OC-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.8.1.4
ocnCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.8.1.5
ocnCrntPMOPRValueThe optical power received on the input of the OC-N facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.6
ocnCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.7
ocnCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.8
ocnCrntPMOPTValueThe optical power transmitted at the output of the OC-N facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.9
ocnCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.10
ocnCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.11
ocnCrntPMTempValueThe temperature measured on the OC-N facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.12
ocnCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.13
ocnCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.14
ocnCrntPMSupplyVoltageValueThe supply voltage measured on the OC-N facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.15
ocnCrntPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.16
ocnCrntPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.17
ocnCrntPMLBCValueThe laser bias current measured on the OC-N facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.18
ocnCrntPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.19
ocnCrntPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.20
ocnCrntPMCVSValueThe count of coding violations at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.21
ocnCrntPMCVSTimeStampThe date and time stamp of the section layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.22
ocnCrntPMCVSValidityIndicates the validity of the provided section layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.23
ocnCrntPMESSValueThe count of errored seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.24
ocnCrntPMESSTimeStampThe date and time stamp of the section layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.25
ocnCrntPMESSValidityIndicates the validity of the provided section layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.26
ocnCrntPMSESSValueThe count of severely errored seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.27
ocnCrntPMSESSTimeStampThe date and time stamp of the section layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.28
ocnCrntPMSESSValidityIndicates the validity of the provided section layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.29
ocnCrntPMSEFSSValueThe count of severely errored framing seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.30
ocnCrntPMSEFSSTimeStampThe date and time stamp of the section layer severely errored framing seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.31
ocnCrntPMSEFSSValidityIndicates the validity of the provided section layer severely errored framing seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.32
ocnCrntPMSupplyVoltage2ValueThe value of the second supply voltage source measured on the OC-N facility port transceiver.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.33
ocnCrntPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.34
ocnCrntPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.35
ocnCrntPMCVLValueThe count of coding violations at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.36
ocnCrntPMCVLTimeStampThe date and time stamp of the line layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.37
ocnCrntPMCVLValidityIndicates the validity of the provided line layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.38
ocnCrntPMESLValueThe count of errored seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.39
ocnCrntPMESLTimeStampThe date and time stamp of the line layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.40
ocnCrntPMESLValidityIndicates the validity of the provided line layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.41
ocnCrntPMSESLValueThe count of severely errored seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.42
ocnCrntPMSESLTimeStampThe date and time stamp of the line layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.43
ocnCrntPMSESLValidityIndicates the validity of the provided line layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.44
ocnCrntPMUASLValueThe count of unavailable seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.45
ocnCrntPMUASLTimeStampThe date and time stamp of the line layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.46
ocnCrntPMUASLValidityIndicates the validity of the provided line layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.47
ocnCrntPMOTUEBValueThe count of OTU digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.48
ocnCrntPMOTUEBTimeStampThe date and time stamp of the OTU digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.49
ocnCrntPMOTUEBValidityIndicates the validity of the provided OTU digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.50
ocnCrntPMOTUBBEValueThe count of OTU digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.51
ocnCrntPMOTUBBETimeStampThe date and time stamp of the OTU digital wrapper layer background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.52
ocnCrntPMOTUBBEValidityIndicates the validity of the provided OTU digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.53
ocnCrntPMOTUESValueThe count of OTU digital wrapper layer errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.54
ocnCrntPMOTUESTimeStampThe date and time stamp of the OTU digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.55
ocnCrntPMOTUESValidityIndicates the validity of the provided OTU digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.56
ocnCrntPMOTUSESValueThe count of OTU digital wrapper layer severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.57
ocnCrntPMOTUSESTimeStampThe date and time stamp of the OTU digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.58
ocnCrntPMOTUSESValidityIndicates the validity of the provided OTU digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.59
ocnCrntPMOTUOFSValueThe count of OTU digital wrapper layer out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.60
ocnCrntPMOTUOFSTimeStampThe date and time stamp of the OTU digital wrapper layer out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.61
ocnCrntPMOTUOFSValidityIndicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.62
ocnCrntPMNBITCRValueThe count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.63
ocnCrntPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.64
ocnCrntPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.65
ocnCrntPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.66
ocnCrntPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.67
ocnCrntPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.68
ocnCrntPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.69
ocnCrntPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.70
ocnCrntPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.71
ocnCrntPMCVSInitializeUsed to initialize the value of the ocnCrntPMCVSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.72
ocnCrntPMESSInitializeUsed to initialize the value of the ocnCrntPMESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.73
ocnCrntPMSESSInitializeUsed to initialize the value of the ocnCrntPMSESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.74
ocnCrntPMSEFSSInitializeUsed to initialize the value of the ocnCrntPMSEFSSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.75
ocnCrntPMCVLInitializeUsed to initialize the value of the ocnCrntPMCVLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.76
ocnCrntPMESLInitializeUsed to initialize the value of the ocnCrntPMESLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.77
ocnCrntPMSESLInitializeUsed to initialize the value of the ocnCrntPMSESLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.78
ocnCrntPMUASLInitializeUsed to initialize the value of the ocnCrntPMUASLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.79
ocnCrntPMOTUEBInitializeUsed to initialize the value of the ocnCrntPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.80
ocnCrntPMOTUBBEInitializeUsed to initialize the value of the ocnCrntPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.81
ocnCrntPMOTUESInitializeUsed to initialize the value of the ocnCrntPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.82
ocnCrntPMOTUSESInitializeUsed to initialize the value of the ocnCrntPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.83
ocnCrntPMOTUOFSInitializeUsed to initialize the value of the ocnCrntPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.84
ocnCrntPMNBITCRInitializeUsed to initialize the value of the ocnCrntPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.85
ocnCrntPMNBYTCRInitializeUsed to initialize the value of the ocnCrntPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.86
ocnCrntPMUNCRCDWInitializeUsed to initialize the value of the ocnCrntPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.87
ocnCrntPMOTNBERValueThe instantaneous BER of OC-192 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.88
ocnCrntPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.89
ocnCrntPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.90
ocnCrntPMOTNBERInitializeUsed to initialize the value of the ocnCrntPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.91
ocnCrntPMOTNAVGBERValueThe interval/average BER of OC-192 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.92
ocnCrntPMOTNAVGBERTimeStampThe date and time stamp of the interval/average BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.93
ocnCrntPMOTNAVGBERValidityIndicates the validity of the provided interval/average BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.94
ocnCrntPMOTNAVGBERInitializeUsed to initialize the value of the ocnCrntPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.95
ocnCrntPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.8.1.96
ocnCrntPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.97
ocnCrntPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.98
ocnCrntPMNBITCR64BitInitializeUsed to initialize the value of the ocnCrntPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.99
ocnCrntPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.8.1.100
ocnCrntPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.101
ocnCrntPMNBYTCR64BitValidityIndicates the validity of the provided 64-bit number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.102
ocnCrntPMNBYTCR64BitInitializeUsed to initialize the value of the ocnCrntPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.103
ocnCrntPMUASSValueThe count of unavailable seconds at the section layer. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.104
ocnCrntPMUASSTimeStampThe date and time stamp of the unavailable seconds at the section layerro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.105
ocnCrntPMUASSValidityIndicates the validity of the unavailable seconds at the section layer.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.106
ocnCrntPMUASSInitializeUsed to initialize the value of the ocnCrntPMUASSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.107
ocnCrntPMOTUUASValueThe count of OTU digital wrapper layer unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.8.1.108
ocnCrntPMOTUUASTimeStampThe date and time stamp of the OTU digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.109
ocnCrntPMOTUUASValidityIndicates the validity of the provided OTU digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.110
ocnCrntPMOTUUASInitializeUsed to initialize the value of the ocnCrntPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.111
ocnCrntPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.112
ocnCrntPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.113
ocnCrntPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.114
ocnCrntPMOPRMinInitializeUsed to initialize the value of the ocnCrntPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.115
ocnCrntPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.116
ocnCrntPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.117
ocnCrntPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.118
ocnCrntPMOPRMaxInitializeUsed to initialize the value of the ocnCrntPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.119
ocnCrntPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.120
ocnCrntPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.121
ocnCrntPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.122
ocnCrntPMOPRAvgInitializeUsed to initialize the value of the ocnCrntPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.123
ocnCrntPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.124
ocnCrntPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.125
ocnCrntPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.126
ocnCrntPMOPTMinInitializeUsed to initialize the value of the ocnCrntPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.127
ocnCrntPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.128
ocnCrntPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.129
ocnCrntPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.130
ocnCrntPMOPTMaxInitializeUsed to initialize the value of the ocnCrntPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.131
ocnCrntPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.8.1.132
ocnCrntPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.8.1.133
ocnCrntPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.8.1.134
ocnCrntPMOPTAvgInitializeUsed to initialize the value of the ocnCrntPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.8.1.135
ocnHistPMTableA table of historical performance monitoring statistics collected for the SONET OC-N facilities on the NE.
SEQUENCE OF OcnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.9
ocnHistPMEntryThe row entry object of the SONET OC-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given OC-N facility.
OcnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.9.1
ocnHistPMTypeIdxThe type of the OC-N facility targeted for PMs.
OcnType
.1.3.6.1.4.1.18070.2.2.1.6.9.1.1
ocnHistPMShelfIdxThe number of the shelf on which the OC-N facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.2
ocnHistPMSlotIdxThe number of the slot within which the OC-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.9.1.3
ocnHistPMPortIdxThe number of the port on the circuit pack on which the OC-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.9.1.4
ocnHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.9.1.5
ocnHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.9.1.6
ocnHistPMOPRValueThe optical power received on the input of the OC-N facility.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.7
ocnHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.8
ocnHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.9
ocnHistPMOPTValueThe optical power transmitted at the output of the OC-N facility.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.10
ocnHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.11
ocnHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.12
ocnHistPMTempValueThe temperature measured on the OC-N facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.13
ocnHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.14
ocnHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.15
ocnHistPMSupplyVoltageValueThe supply voltage measured on the OC-N facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.16
ocnHistPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.17
ocnHistPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.18
ocnHistPMLBCValueThe laser bias current measured on the OC-N facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.19
ocnHistPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.20
ocnHistPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.21
ocnHistPMCVSValueThe count of coding violations at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.22
ocnHistPMCVSTimeStampThe date and time stamp of the section layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.23
ocnHistPMCVSValidityIndicates the validity of the provided section layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.24
ocnHistPMESSValueThe count of errored seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.25
ocnHistPMESSTimeStampThe date and time stamp of the section layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.26
ocnHistPMESSValidityIndicates the validity of the provided section layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.27
ocnHistPMSESSValueThe count of severely errored seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.28
ocnHistPMSESSTimeStampThe date and time stamp of the section layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.29
ocnHistPMSESSValidityIndicates the validity of the provided section layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.30
ocnHistPMSEFSSValueThe count of severely errored framing seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.31
ocnHistPMSEFSSTimeStampThe date and time stamp of the section layer severely errored framing seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.32
ocnHistPMSEFSSValidityIndicates the validity of the provided section layer severely errored framing seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.33
ocnHistPMSupplyVoltage2ValueThe value of the second supply voltage source measured on the OC-N facility port transceiver.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.34
ocnHistPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.35
ocnHistPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.36
ocnHistPMCVLValueThe count of coding violations at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.37
ocnHistPMCVLTimeStampThe date and time stamp of the line layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.38
ocnHistPMCVLValidityIndicates the validity of the provided line layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.39
ocnHistPMESLValueThe count of errored seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.40
ocnHistPMESLTimeStampThe date and time stamp of the line layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.41
ocnHistPMESLValidityIndicates the validity of the provided line layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.42
ocnHistPMSESLValueThe count of severely errored seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.43
ocnHistPMSESLTimeStampThe date and time stamp of the line layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.44
ocnHistPMSESLValidityIndicates the validity of the provided line layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.45
ocnHistPMUASLValueThe count of unavailable seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.46
ocnHistPMUASLTimeStampThe date and time stamp of the line layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.47
ocnHistPMUASLValidityIndicates the validity of the provided line layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.48
ocnHistPMOTUEBValueThe count of OTU digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.49
ocnHistPMOTUEBTimeStampThe date and time stamp of the OTU digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.50
ocnHistPMOTUEBValidityIndicates the validity of the provided OTU digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.51
ocnHistPMOTUBBEValueThe count of OTU digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.52
ocnHistPMOTUBBETimeStampThe date and time stamp of the OTU digital wrapper layer background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.53
ocnHistPMOTUBBEValidityIndicates the validity of the provided OTU digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.54
ocnHistPMOTUESValueThe count of OTU digital wrapper layer errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.55
ocnHistPMOTUESTimeStampThe date and time stamp of the OTU digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.56
ocnHistPMOTUESValidityIndicates the validity of the provided OTU digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.57
ocnHistPMOTUSESValueThe count of OTU digital wrapper layer severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.58
ocnHistPMOTUSESTimeStampThe date and time stamp of the OTU digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.59
ocnHistPMOTUSESValidityIndicates the validity of the provided OTU digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.60
ocnHistPMOTUOFSValueThe count of OTU digital wrapper layer out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.61
ocnHistPMOTUOFSTimeStampThe date and time stamp of the OTU digital wrapper layer out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.62
ocnHistPMOTUOFSValidityIndicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.63
ocnHistPMNBITCRValueThe count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.64
ocnHistPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.65
ocnHistPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.66
ocnHistPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.67
ocnHistPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.68
ocnHistPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.69
ocnHistPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.70
ocnHistPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.71
ocnHistPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.72
ocnHistPMCVSInitializeUsed to initialize the value of the ocnHistPMCVSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.73
ocnHistPMESSInitializeUsed to initialize the value of the ocnHistPMESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.74
ocnHistPMSESSInitializeUsed to initialize the value of the ocnHistPMSESSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.75
ocnHistPMSEFSSInitializeUsed to initialize the value of the ocnHistPMSEFSSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.76
ocnHistPMCVLInitializeUsed to initialize the value of the ocnHistPMCVLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.77
ocnHistPMESLInitializeUsed to initialize the value of the ocnHistPMESLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.78
ocnHistPMSESLInitializeUsed to initialize the value of the ocnHistPMSESLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.79
ocnHistPMUASLInitializeUsed to initialize the value of the ocnHistPMUASLValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.80
ocnHistPMOTUEBInitializeUsed to initialize the value of the ocnHistPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.81
ocnHistPMOTUBBEInitializeUsed to initialize the value of the ocnHistPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.82
ocnHistPMOTUESInitializeUsed to initialize the value of the ocnHistPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.83
ocnHistPMOTUSESInitializeUsed to initialize the value of the ocnHistPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.84
ocnHistPMOTUOFSInitializeUsed to initialize the value of the ocnHistPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.85
ocnHistPMNBITCRInitializeUsed to initialize the value of the ocnHistPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.86
ocnHistPMNBYTCRInitializeUsed to initialize the value of the ocnHistPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.87
ocnHistPMUNCRCDWInitializeUsed to initialize the value of the ocnHistPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.88
ocnHistPMOTNBERValueThe instantaneous BER of OC-192 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.89
ocnHistPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.90
ocnHistPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.91
ocnHistPMOTNBERInitializeUsed to initialize the value of the ocnHistPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.92
ocnHistPMOTNAVGBERValueThe interval/average BER of OC-192 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.93
ocnHistPMOTNAVGBERTimeStampThe date and time stamp of the interval/average BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.94
ocnHistPMOTNAVGBERValidityIndicates the validity of the provided interval/average BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.95
ocnHistPMOTNAVGBERInitializeUsed to initialize the value of the ocnHistPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.96
ocnHistPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.9.1.97
ocnHistPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.98
ocnHistPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.99
ocnHistPMNBITCR64BitInitializeUsed to initialize the value of the ocnHistPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.100
ocnHistPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.9.1.101
ocnHistPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.102
ocnHistPMNBYTCR64BitValidityIndicates the validity of the provided 64-bit number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.103
ocnHistPMNBYTCR64BitInitializeUsed to initialize the value of the ocnHistPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.104
ocnHistPMUASSValueThe count of unavailable seconds at the section layer. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.105
ocnHistPMUASSTimeStampThe date and time stamp of the unavailable seconds at the section layer.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.106
ocnHistPMUASSValidityIndicates the validity of the unavailable seconds at the section layer.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.107
ocnHistPMUASSInitializeUsed to initialize the value of the ocnHistPMUASSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.108
ocnHistPMOTUUASValueThe count of OTU digital wrapper layer unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.9.1.109
ocnHistPMOTUUASTimeStampThe date and time stamp of the OTU digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.110
ocnHistPMOTUUASValidityIndicates the validity of the provided OTU digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.111
ocnHistPMOTUUASInitializeUsed to initialize the value of the ocnHistPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.112
ocnHistPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.113
ocnHistPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.114
ocnHistPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.115
ocnHistPMOPRMinInitializeUsed to initialize the value of the ocnHistPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.116
ocnHistPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.117
ocnHistPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.118
ocnHistPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.119
ocnHistPMOPRMaxInitializeUsed to initialize the value of the ocnHistPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.120
ocnHistPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.121
ocnHistPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.122
ocnHistPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.123
ocnHistPMOPRAvgInitializeUsed to initialize the value of the ocnHistPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.124
ocnHistPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.125
ocnHistPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.126
ocnHistPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.127
ocnHistPMOPTMinInitializeUsed to initialize the value of the ocnHistPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.128
ocnHistPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.129
ocnHistPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.130
ocnHistPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.131
ocnHistPMOPTMaxInitializeUsed to initialize the value of the ocnHistPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.132
ocnHistPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.9.1.133
ocnHistPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.9.1.134
ocnHistPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.9.1.135
ocnHistPMOPTAvgInitializeUsed to initialize the value of the ocnHistPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.9.1.136
ocnPMThresholdTableA table of threshold levels for performance monitoring counter values on SONET OC-N facilities, that are used in the generation of threshold crossing alerts.
SEQUENCE OF OcnPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.10
ocnPMThresholdEntryThe row entry object of the SONET OC-N performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual OC-N facility.
OcnPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.10.1
ocnPMThresholdTypeIdxThe type of the OC-N facility targeted for PM thresholds.
OcnType
.1.3.6.1.4.1.18070.2.2.1.6.10.1.1
ocnPMThresholdShelfIdxThe shelf number on which the OC-N facility targeted for PM thresholds is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.10.1.2
ocnPMThresholdSlotIdxThe slot number on which the OC-N facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.10.1.3
ocnPMThresholdPortIdxThe number of the port on the circuit pack on which the OC-N facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.10.1.4
ocnPMThresholdIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.10.1.5
ocnPMThresholdCVSValueThe threshold for the count of coding violations at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.6
ocnPMThresholdESSValueThe threshold for the count of errored seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.7
ocnPMThresholdSESSValueThe threshold fro the count of severely errored seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.8
ocnPMThresholdSEFSSValueThe threshold for the count of severely errored framing seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.9
ocnPMThresholdCVLValueThe threshold for the count of coding violations at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.10
ocnPMThresholdESLValueThe threshold for the count of errored seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.11
ocnPMThresholdSESLValueThe threshold for the count of severely errored seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.12
ocnPMThresholdUASLValueThe threshold for the count of unavailable seconds at the line layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.13
ocnPMThresholdOTUEBValueThe threshold for the count of errored blocks at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.14
ocnPMThresholdOTUBBEValueThe threshold for the count of background block errors at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.15
ocnPMThresholdOTUESValueThe threshold for the count of errored seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.16
ocnPMThresholdOTUSESValueThe threshold for the count of severely errored seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.17
ocnPMThresholdOTUOFSValueThe threshold for the count of out-of-frame seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.18
ocnPMThresholdUNCRCDWValueThe threshold for the count of uncorrectable codewords.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.21
ocnPMThresholdUASSValueThe threshold for the count of unavailable seconds at the section layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.22
ocnPMThresholdOTUUASValueThe threshold for the count of unavailable seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.10.1.23
stsnCrntPMTableA table of current performance monitoring statistics collected for the SONET STS-N facilities on the NE.
SEQUENCE OF StsnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.11
stsnCrntPMEntryThe row entry object of the SONET STS-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given STS-N facility.
StsnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.11.1
stsnCrntPMTypeIdxThe type of STS-N facility targeted for PMs.
StsnType
.1.3.6.1.4.1.18070.2.2.1.6.11.1.1
stsnCrntPMShelfIdxThe number of the shelf of the STS-N facility targeted for PMs.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.11.1.2
stsnCrntPMSlotIdxThe number of the slot of the STS-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.11.1.3
stsnCrntPMPortIdxThe number of the port on the circuit pack of the STS-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.11.1.4
stsnCrntPMIdxThe sts index number of the STS-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.11.1.5
stsnCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.11.1.6
stsnCrntPMCVPValueThe count of coding violations at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.11.1.7
stsnCrntPMCVPTimeStampThe date and time stamp of the path layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.11.1.8
stsnCrntPMCVPValidityIndicates the validity of the provided path layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.11.1.9
stsnCrntPMESPValueThe count of errored seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.11.1.10
stsnCrntPMESPTimeStampThe date and time stamp of the path layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.11.1.11
stsnCrntPMESPValidityIndicates the validity of the provided path layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.11.1.12
stsnCrntPMSESPValueThe count of severely errored seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.11.1.13
stsnCrntPMSESPTimeStampThe date and time stamp of the path layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.11.1.14
stsnCrntPMSESPValidityIndicates the validity of the provided path layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.11.1.15
stsnCrntPMUASPValueThe count of unavailable seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.11.1.16
stsnCrntPMUASPTimeStampThe date and time stamp of the path layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.11.1.17
stsnCrntPMUASPValidityIndicates the validity of the provided path layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.11.1.18
stsnCrntPMFCPValueThe failure count at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.11.1.19
stsnCrntPMFCPTimeStampThe date and time stamp of the path layer failure count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.11.1.20
stsnCrntPMFCPValidityIndicates the validity of the provided path layer failure count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.11.1.21
stsnCrntPMCVPInitializeUsed to initialize the value of the stsnCrntPMCVPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.11.1.22
stsnCrntPMESPInitializeUsed to initialize the value of the stsnCrntPMESPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.11.1.23
stsnCrntPMSESPInitializeUsed to initialize the value of the stsnCrntPMSESPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.11.1.24
stsnCrntPMUASPInitializeUsed to initialize the value of the stsnCrntPMUASPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.11.1.25
stsnCrntPMFCPInitializeUsed to initialize the value of the stsnCrntPMFCPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.11.1.26
stsnHistPMTableA table of historical performance monitoring statistics collected for the SONET STS-N facilities on the NE.
SEQUENCE OF StsnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.12
stsnHistPMEntryThe row entry object of the SONET STS-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given STS-N facility.
StsnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.12.1
stsnHistPMTypeIdxThe type of the STS-N facility targeted for PMs.
StsnType
.1.3.6.1.4.1.18070.2.2.1.6.12.1.1
stsnHistPMShelfIdxThe number of the shelf of the STS-N facility targeted for PMs.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.12.1.2
stsnHistPMSlotIdxThe number of the slot of the STS-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.12.1.3
stsnHistPMPortIdxThe number of the port on the circuit pack of the STS-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.12.1.4
stsnHistPMIdxThe sts index number of the STS-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.12.1.5
stsnHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.12.1.6
stsnHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.12.1.7
stsnHistPMCVPValueThe count of coding violations at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.12.1.8
stsnHistPMCVPTimeStampThe date and time stamp of the path layer coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.12.1.9
stsnHistPMCVPValidityIndicates the validity of the provided path layer coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.12.1.10
stsnHistPMESPValueThe count of errored seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.12.1.11
stsnHistPMESPTimeStampThe date and time stamp of the path layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.12.1.12
stsnHistPMESPValidityIndicates the validity of the provided path layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.12.1.13
stsnHistPMSESPValueThe count of severely errored seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.12.1.14
stsnHistPMSESPTimeStampThe date and time stamp of the path layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.12.1.15
stsnHistPMSESPValidityIndicates the validity of the provided path layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.12.1.16
stsnHistPMUASPValueThe count of unavailable seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.12.1.17
stsnHistPMUASPTimeStampThe date and time stamp of the path layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.12.1.18
stsnHistPMUASPValidityIndicates the validity of the provided path layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.12.1.19
stsnHistPMFCPValueThe failure count at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.12.1.20
stsnHistPMFCPTimeStampThe date and time stamp of the path layer failure count.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.12.1.21
stsnHistPMFCPValidityIndicates the validity of the provided path layer failure count.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.12.1.22
stsnHistPMCVPInitializeUsed to initialize the value of the stsnHistPMCVPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.12.1.23
stsnHistPMESPInitializeUsed to initialize the value of the stsnHistPMESPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.12.1.24
stsnHistPMSESPInitializeUsed to initialize the value of the stsnHistPMSESPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.12.1.25
stsnHistPMUASPInitializeUsed to initialize the value of the stsnHistPMUASPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.12.1.26
stsnHistPMFCPInitializeUsed to initialize the value of the stsnHistPMFCPValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.12.1.27
stsnPMThresholdByPortTableA table of threshold levels for performance monitoring counter values on SONET STS-N facilities, that are used in the generation of threshold crossing alerts. The STS-N threshold settings will be the same for all STS channels on a given OC-N facility port.
SEQUENCE OF StsnPMThresholdByPortEntry
.1.3.6.1.4.1.18070.2.2.1.6.13
stsnPMThresholdByPortEntryThe row entry object of the SONET STS-N performance monitoring threshold by port table. Each row of this table contains a set of PM thresholds for a given interval type that applies to all the STS-N channels on an OC-N facility port.
StsnPMThresholdByPortEntry
.1.3.6.1.4.1.18070.2.2.1.6.13.1
stsnPMThresholdByPortTypeIdxThe type of the STS-N facilities targeted for PM thresholds.
StsnType
.1.3.6.1.4.1.18070.2.2.1.6.13.1.1
stsnPMThresholdByPortShelfIdxThe shelf number of the STS-N facilities targeted for PM thresholds.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.13.1.2
stsnPMThresholdByPortSlotIdxThe slot number of the STS-N facilities targeted for PM thresholds.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.13.1.3
stsnPMThresholdByPortIdxThe number of the port on the circuit pack of the STS-N facilities targeted for PM thresholds.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.13.1.4
stsnPMThresholdByPortIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.13.1.5
stsnPMThresholdByPortCVPValueThe threshold for the count of coding violations at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.13.1.6
stsnPMThresholdByPortESPValueThe threshold for the count of errored seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.13.1.9
stsnPMThresholdByPortSESPValueThe threshold for the count of severely errored seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.13.1.10
stsnPMThresholdByPortUASPValueThe threshold for the count of unavailable seconds at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.13.1.11
stsnPMThresholdByPortFCPValueThe threshold for the failure count at the path layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.13.1.12
stmnCrntPMTableA table of current performance monitoring statistics collected for the SDH STM-N facilities on the NE.
SEQUENCE OF StmnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.14
stmnCrntPMEntryThe row entry object of the SDH STM-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given STM-N facility.
StmnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.14.1
stmnCrntPMTypeIdxThe type of STM-N facility targeted for PMs.
StmnType
.1.3.6.1.4.1.18070.2.2.1.6.14.1.1
stmnCrntPMShelfIdxThe number of the shelf on which the STM-N facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.2
stmnCrntPMSlotIdxThe number of the slot within which the STM-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.14.1.3
stmnCrntPMPortIdxThe number of the port on the circuit pack on which the STM-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.14.1.4
stmnCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.14.1.5
stmnCrntPMOPRValueThe optical power received on the input of the OC-N facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.6
stmnCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.7
stmnCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.8
stmnCrntPMOPTValueThe optical power transmitted at the output of the STM-N facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.9
stmnCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.10
stmnCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.11
stmnCrntPMTempValueThe temperature measured on the STM-N facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.12
stmnCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.13
stmnCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.14
stmnCrntPMSupplyVoltageValueThe supply voltage measured on the STM-N facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.15
stmnCrntPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.16
stmnCrntPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.17
stmnCrntPMLBCValueThe laser bias current measured on the STM-N facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.18
stmnCrntPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.19
stmnCrntPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.20
stmnCrntPMRSEBValueThe count of regenerator section errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.21
stmnCrntPMRSEBTimeStampThe date and time stamp of the regenerator section errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.22
stmnCrntPMRSEBValidityIndicates the validity of the provided regenerator section errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.23
stmnCrntPMRSBBEValueThe count of regenerator section background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.24
stmnCrntPMRSBBETimeStampThe date and time stamp of the regenerator section background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.25
stmnCrntPMRSBBEValidityIndicates the validity of the provided regenerator section background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.26
stmnCrntPMRSESValueThe count of regenerator section errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.27
stmnCrntPMRSESTimeStampThe date and time stamp of the regenerator section errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.28
stmnCrntPMRSESValidityIndicates the validity of the provided regenerator section errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.29
stmnCrntPMRSSESValueThe count of regenerator section severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.30
stmnCrntPMRSSESTimeStampThe date and time stamp of the regenerator section severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.31
stmnCrntPMRSSESValidityIndicates the validity of the provided regenerator section severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.32
stmnCrntPMRSOFSValueThe count of regenerator section out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.33
stmnCrntPMRSOFSTimeStampThe date and time stamp of the regenerator section out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.34
stmnCrntPMRSOFSValidityIndicates the validity of the provided regenerator section out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.35
stmnCrntPMSupplyVoltage2ValueThe value of the second supply voltage source measured on the STM-N facility port transceiver.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.36
stmnCrntPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.37
stmnCrntPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.38
stmnCrntPMMSEBValueThe count of multiplex section errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.39
stmnCrntPMMSEBTimeStampThe date and time stamp of the multiplex section errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.40
stmnCrntPMMSEBValidityIndicates the validity of the provided multiplex section errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.41
stmnCrntPMMSBBEValueThe count of multiplex section background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.42
stmnCrntPMMSBBETimeStampThe date and time stamp of the multiplex section background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.43
stmnCrntPMMSBBEValidityIndicates the validity of the provided multiplex section background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.44
stmnCrntPMMSESValueThe count of multiplex section errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.45
stmnCrntPMMSESTimeStampThe date and time stamp of the multiplex section errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.46
stmnCrntPMMSESValidityIndicates the validity of the provided multiplex section errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.47
stmnCrntPMMSSESValueThe count of multiplex section severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.48
stmnCrntPMMSSESTimeStampThe date and time stamp of the multiplex section severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.49
stmnCrntPMMSSESValidityIndicates the validity of the provided multiplex section severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.50
stmnCrntPMMSUASValueThe count of multiplex section unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.51
stmnCrntPMMSUASTimeStampThe date and time stamp of the multiplex section unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.52
stmnCrntPMMSUASValidityIndicates the validity of the provided multiplex section unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.53
stmnCrntPMOTUEBValueThe count of OTU digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.54
stmnCrntPMOTUEBTimeStampThe date and time stamp of the OTU digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.55
stmnCrntPMOTUEBValidityIndicates the validity of the provided OTU digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.56
stmnCrntPMOTUBBEValueThe count of OTU digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.57
stmnCrntPMOTUBBETimeStampThe date and time stamp of the OTU digital wrapper layer background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.58
stmnCrntPMOTUBBEValidityIndicates the validity of the provided OTU digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.59
stmnCrntPMOTUESValueThe count of OTU digital wrapper layer errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.60
stmnCrntPMOTUESTimeStampThe date and time stamp of the OTU digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.61
stmnCrntPMOTUESValidityIndicates the validity of the provided OTU digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.62
stmnCrntPMOTUSESValueThe count of OTU digital wrapper layer severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.63
stmnCrntPMOTUSESTimeStampThe date and time stamp of the OTU digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.64
stmnCrntPMOTUSESValidityIndicates the validity of the provided OTU digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.65
stmnCrntPMOTUOFSValueThe count of OTU digital wrapper layer out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.66
stmnCrntPMOTUOFSTimeStampThe date and time stamp of the OTU digital wrapper layer out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.67
stmnCrntPMOTUOFSValidityIndicates the validity of the provided OTU digital wrapper layer severely errored framing seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.68
stmnCrntPMNBITCRValueThe count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.69
stmnCrntPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.70
stmnCrntPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.71
stmnCrntPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.72
stmnCrntPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.73
stmnCrntPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.74
stmnCrntPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.75
stmnCrntPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.76
stmnCrntPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.77
stmnCrntPMRSEBInitializeUsed to initialize the value of the stmnCrntPMRSEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.78
stmnCrntPMRSBBEInitializeUsed to initialize the value of the stmnCrntPMRSBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.79
stmnCrntPMRSESInitializeUsed to initialize the value of the stmnCrntPMRSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.80
stmnCrntPMRSSESInitializeUsed to initialize the value of the stmnCrntPMRSSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.81
stmnCrntPMRSOFSInitializeUsed to initialize the value of the stmnCrntPMRSOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.82
stmnCrntPMMSEBInitializeUsed to initialize the value of the stmnCrntPMMSEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.83
stmnCrntPMMSBBEInitializeUsed to initialize the value of the stmnCrntPMMSBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.84
stmnCrntPMMSESInitializeUsed to initialize the value of the stmnCrntPMMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.85
stmnCrntPMMSSESInitializeUsed to initialize the value of the stmnCrntPMMSSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.86
stmnCrntPMMSUASInitializeUsed to initialize the value of the stmnCrntPMMSUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.87
stmnCrntPMOTUEBInitializeUsed to initialize the value of the stmnCrntPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.88
stmnCrntPMOTUBBEInitializeUsed to initialize the value of the stmnCrntPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.89
stmnCrntPMOTUESInitializeUsed to initialize the value of the stmnCrntPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.90
stmnCrntPMOTUSESInitializeUsed to initialize the value of the stmnCrntPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.91
stmnCrntPMOTUOFSInitializeUsed to initialize the value of the stmnCrntPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.92
stmnCrntPMNBITCRInitializeUsed to initialize the value of the stmnCrntPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.93
stmnCrntPMNBYTCRInitializeUsed to initialize the value of the stmnCrntPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.94
stmnCrntPMUNCRCDWInitializeUsed to initialize the value of the stmnCrntPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.95
stmnCrntPMOTNBERValueThe instantaneous BER of STM-64 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.96
stmnCrntPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.97
stmnCrntPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.98
stmnCrntPMOTNBERInitializeUsed to initialize the value of the stmnCrntPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.99
stmnCrntPMOTNAVGBERValueThe interval/average BER of STM-64 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.100
stmnCrntPMOTNAVGBERTimeStampThe date and time stamp of the interval/average BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.101
stmnCrntPMOTNAVGBERValidityIndicates the validity of the provided interval/average BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.102
stmnCrntPMOTNAVGBERInitializeUsed to initialize the value of the stmnCrntPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.103
stmnCrntPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.14.1.104
stmnCrntPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.105
stmnCrntPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.106
stmnCrntPMNBITCR64BitInitializeUsed to initialize the value of the stmnCrntPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.107
stmnCrntPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.14.1.108
stmnCrntPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.109
stmnCrntPMNBYTCR64BitValidityIndicates the validity of the provided 64-bit number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.110
stmnCrntPMNBYTCR64BitInitializeUsed to initialize the value of the stmnCrntPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.111
stmnCrntPMRSUASValueThe count of regenerator section unavailable seconds. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.112
stmnCrntPMRSUASTimeStampThe date and time stamp of the regenerator section unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.113
stmnCrntPMRSUASValidityIndicates the validity of the provided regenerator section unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.114
stmnCrntPMRSUASInitializeUsed to initialize the value of the stmnCrntPMRSUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.115
stmnCrntPMOTUUASValueThe count of OTU digital wrapper layer unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.14.1.116
stmnCrntPMOTUUASTimeStampThe date and time stamp of the OTU digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.117
stmnCrntPMOTUUASValidityIndicates the validity of the provided OTU digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.118
stmnCrntPMOTUUASInitializeUsed to initialize the value of the stmnCrntPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.119
stmnCrntPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.120
stmnCrntPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.121
stmnCrntPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.122
stmnCrntPMOPRMinInitializeUsed to initialize the value of the stmnCrntPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.123
stmnCrntPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.124
stmnCrntPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.125
stmnCrntPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.126
stmnCrntPMOPRMaxInitializeUsed to initialize the value of the stmnCrntPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.127
stmnCrntPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.128
stmnCrntPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.129
stmnCrntPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.130
stmnCrntPMOPRAvgInitializeUsed to initialize the value of the stmnCrntPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.131
stmnCrntPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.132
stmnCrntPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.133
stmnCrntPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.134
stmnCrntPMOPTMinInitializeUsed to initialize the value of the stmnCrntPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.135
stmnCrntPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.136
stmnCrntPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.137
stmnCrntPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.138
stmnCrntPMOPTMaxInitializeUsed to initialize the value of the stmnCrntPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.139
stmnCrntPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.14.1.140
stmnCrntPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.14.1.141
stmnCrntPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.14.1.142
stmnCrntPMOPTAvgInitializeUsed to initialize the value of the stmnCrntPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.14.1.143
stmnHistPMTableA table of historical performance monitoring statistics collected for the SDH STM-N facilities on the NE.
SEQUENCE OF StmnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.15
stmnHistPMEntryThe row entry object of the SDH STM-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given STM-N facility.
StmnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.15.1
stmnHistPMTypeIdxThe type of the STM-N facility targeted for PMs.
StmnType
.1.3.6.1.4.1.18070.2.2.1.6.15.1.1
stmnHistPMShelfIdxThe number of the shelf on which the STM-N facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.2
stmnHistPMSlotIdxThe number of the slot within which the STM-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.15.1.3
stmnHistPMPortIdxThe number of the port on the circuit pack on which the STM-N facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.15.1.4
stmnHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.15.1.5
stmnHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.15.1.6
stmnHistPMOPRValueThe optical power received on the input of the STM-N facility.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.7
stmnHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.8
stmnHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.9
stmnHistPMOPTValueThe optical power transmitted at the output of the STM-N facility.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.10
stmnHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.11
stmnHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.12
stmnHistPMTempValueThe temperature measured on the STM-N facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.13
stmnHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.14
stmnHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.15
stmnHistPMSupplyVoltageValueThe supply voltage measured on the STM-N facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.16
stmnHistPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.17
stmnHistPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.18
stmnHistPMLBCValueThe laser bias current measured on the STM-N facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.19
stmnHistPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.20
stmnHistPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.21
stmnHistPMRSEBValueThe count of regenerator section errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.22
stmnHistPMRSEBTimeStampThe date and time stamp of the regenerator section errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.23
stmnHistPMRSEBValidityIndicates the validity of the provided regenerator section errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.24
stmnHistPMRSBBEValueThe count of regenerator section background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.25
stmnHistPMRSBBETimeStampThe date and time stamp of the regenerator section background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.26
stmnHistPMRSBBEValidityIndicates the validity of the provided regenerator section background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.27
stmnHistPMRSESValueThe count of regenerator section errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.28
stmnHistPMRSESTimeStampThe date and time stamp of the regenerator section errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.29
stmnHistPMRSESValidityIndicates the validity of the provided regenerator section errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.30
stmnHistPMRSSESValueThe count of regenerator section severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.31
stmnHistPMRSSESTimeStampThe date and time stamp of the regenerator section severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.32
stmnHistPMRSSESValidityIndicates the validity of the provided regenerator section severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.33
stmnHistPMRSOFSValueThe count of regenerator section out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.34
stmnHistPMRSOFSTimeStampThe date and time stamp of the regenerator section out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.35
stmnHistPMRSOFSValidityIndicates the validity of the provided regenerator section out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.36
stmnHistPMSupplyVoltage2ValueThe value of the second supply voltage source measured on the STM-N facility port transceiver.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.37
stmnHistPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.38
stmnHistPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.39
stmnHistPMMSEBValueThe count of multiplex section errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.40
stmnHistPMMSEBTimeStampThe date and time stamp of the multiplex section errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.41
stmnHistPMMSEBValidityIndicates the validity of the provided multiplex section errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.42
stmnHistPMMSBBEValueThe count of multiplex section background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.43
stmnHistPMMSBBETimeStampThe date and time stamp of the multiplex section background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.44
stmnHistPMMSBBEValidityIndicates the validity of the provided multiplex section background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.45
stmnHistPMMSESValueThe count of multiplex section errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.46
stmnHistPMMSESTimeStampThe date and time stamp of the multiplex section errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.47
stmnHistPMMSESValidityIndicates the validity of the provided multiplex section errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.48
stmnHistPMMSSESValueThe count of multiplex section severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.49
stmnHistPMMSSESTimeStampThe date and time stamp of the multiplex section severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.50
stmnHistPMMSSESValidityIndicates the validity of the provided multiplex section severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.51
stmnHistPMMSUASValueThe count of multiplex section unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.52
stmnHistPMMSUASTimeStampThe date and time stamp of the multiplex section unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.53
stmnHistPMMSUASValidityIndicates the validity of the provided multiplex section unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.54
stmnHistPMOTUEBValueThe count of OTU digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.55
stmnHistPMOTUEBTimeStampThe date and time stamp of the OTU digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.56
stmnHistPMOTUEBValidityIndicates the validity of the provided OTU digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.57
stmnHistPMOTUBBEValueThe count of OTU digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.58
stmnHistPMOTUBBETimeStampThe date and time stamp of the OTU digital wrapper layer background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.59
stmnHistPMOTUBBEValidityIndicates the validity of the provided OTU digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.60
stmnHistPMOTUESValueThe count of OTU digital wrapper layer errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.61
stmnHistPMOTUESTimeStampThe date and time stamp of the OTU digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.62
stmnHistPMOTUESValidityIndicates the validity of the provided OTU digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.63
stmnHistPMOTUSESValueThe count of OTU digital wrapper layer severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.64
stmnHistPMOTUSESTimeStampThe date and time stamp of the OTU digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.65
stmnHistPMOTUSESValidityIndicates the validity of the provided OTU digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.66
stmnHistPMOTUOFSValueThe count of OTU digital wrapper layer out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.67
stmnHistPMOTUOFSTimeStampThe date and time stamp of the OTU digital wrapper layer out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.68
stmnHistPMOTUOFSValidityIndicates the validity of the provided OTU digital wrapper layer severely errored framing seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.69
stmnHistPMNBITCRValueThe count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.70
stmnHistPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.71
stmnHistPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.72
stmnHistPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.73
stmnHistPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.74
stmnHistPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.75
stmnHistPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.76
stmnHistPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.77
stmnHistPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.78
stmnHistPMRSEBInitializeUsed to initialize the value of the stmnHistPMRSEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.79
stmnHistPMRSBBEInitializeUsed to initialize the value of the stmnHistPMRSBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.80
stmnHistPMRSESInitializeUsed to initialize the value of the stmnHistPMRSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.81
stmnHistPMRSSESInitializeUsed to initialize the value of the stmnHistPMRSSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.82
stmnHistPMRSOFSInitializeUsed to initialize the value of the stmnHistPMRSOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.83
stmnHistPMMSEBInitializeUsed to initialize the value of the stmnHistPMMSEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.84
stmnHistPMMSBBEInitializeUsed to initialize the value of the stmnHistPMMSBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.85
stmnHistPMMSESInitializeUsed to initialize the value of the stmnHistPMMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.86
stmnHistPMMSSESInitializeUsed to initialize the value of the stmnHistPMMSSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.87
stmnHistPMMSUASInitializeUsed to initialize the value of the stmnHistPMMSUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.88
stmnHistPMOTUEBInitializeUsed to initialize the value of the stmnHistPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.89
stmnHistPMOTUBBEInitializeUsed to initialize the value of the stmnHistPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.90
stmnHistPMOTUESInitializeUsed to initialize the value of the stmnHistPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.91
stmnHistPMOTUSESInitializeUsed to initialize the value of the stmnHistPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.92
stmnHistPMOTUOFSInitializeUsed to initialize the value of the stmnHistPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.93
stmnHistPMNBITCRInitializeUsed to initialize the value of the stmnHistPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.94
stmnHistPMNBYTCRInitializeUsed to initialize the value of the stmnHistPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.95
stmnHistPMUNCRCDWInitializeUsed to initialize the value of the stmnHistPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.96
stmnHistPMOTNBERValueThe instantaneous BER of STM-64 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.97
stmnHistPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.98
stmnHistPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.99
stmnHistPMOTNBERInitializeUsed to initialize the value of the stmnHistPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.100
stmnHistPMOTNAVGBERValueThe interval/average BER of STM-64 line port provisioned for OTN line mapping.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.101
stmnHistPMOTNAVGBERTimeStampThe date and time stamp of the interval/average BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.102
stmnHistPMOTNAVGBERValidityIndicates the validity of the provided interval/average BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.103
stmnHistPMOTNAVGBERInitializeUsed to initialize the value of the stmnHistPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.104
stmnHistPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.15.1.105
stmnHistPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.106
stmnHistPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.107
stmnHistPMNBITCR64BitInitializeUsed to initialize the value of the stmnCrntPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.108
stmnHistPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.15.1.109
stmnHistPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.110
stmnHistPMNBYTCR64BitValidityIndicates the validity of the provided 64-bit number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.111
stmnHistPMNBYTCR64BitInitializeUsed to initialize the value of the stmnCrntPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.112
stmnHistPMRSUASValueThe count of regenerator section unavailable seconds. This object applies only to STM-64 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.113
stmnHistPMRSUASTimeStampThe date and time stamp of the regenerator section unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.114
stmnHistPMRSUASValidityIndicates the validity of the provided regenerator section unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.115
stmnHistPMRSUASInitializeUsed to initialize the value of the stmnHistPMRSUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.116
stmnHistPMOTUUASValueThe count of OTU digital wrapper layer unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.15.1.117
stmnHistPMOTUUASTimeStampThe date and time stamp of the OTU digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.118
stmnHistPMOTUUASValidityIndicates the validity of the provided OTU digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.119
stmnHistPMOTUUASInitializeUsed to initialize the value of the stmnHistPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.120
stmnHistPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.121
stmnHistPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.122
stmnHistPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.123
stmnHistPMOPRMinInitializeUsed to initialize the value of the stmnHistPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.124
stmnHistPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.125
stmnHistPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.126
stmnHistPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.127
stmnHistPMOPRMaxInitializeUsed to initialize the value of the stmnHistPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.128
stmnHistPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.129
stmnHistPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.130
stmnHistPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.131
stmnHistPMOPRAvgInitializeUsed to initialize the value of the stmnHistPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.132
stmnHistPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.133
stmnHistPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.134
stmnHistPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.135
stmnHistPMOPTMinInitializeUsed to initialize the value of the stmnHistPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.136
stmnHistPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.137
stmnHistPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.138
stmnHistPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.139
stmnHistPMOPTMaxInitializeUsed to initialize the value of the stmnHistPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.140
stmnHistPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.15.1.141
stmnHistPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.15.1.142
stmnHistPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.15.1.143
stmnHistPMOPTAvgInitializeUsed to initialize the value of the stmnHistPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.15.1.144
stmnPMThresholdTableA table of threshold levels for performance monitoring counter values on SDH STM-N facilities, that are used in the generation of threshold crossing alerts.
SEQUENCE OF StmnPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.16
stmnPMThresholdEntryThe row entry object of the SDH STM-N performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual STM-N facility.
StmnPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.16.1
stmnPMThresholdTypeIdxThe type of the STM-N facility targeted for PM thresholds.
StmnType
.1.3.6.1.4.1.18070.2.2.1.6.16.1.1
stmnPMThresholdShelfIdxThe shelf number on which the STM-N facility targeted for PM thresholds is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.16.1.2
stmnPMThresholdSlotIdxThe slot number on which the STM-N facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.16.1.3
stmnPMThresholdPortIdxThe number of the port on the circuit pack on which the STM-N facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.16.1.4
stmnPMThresholdIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.16.1.5
stmnPMThresholdRSEBValueThe threshold for the count of regenerator section errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.6
stmnPMThresholdRSBBEValueThe threshold for the count of regenerator section background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.7
stmnPMThresholdRSESValueThe threshold for the count of regenerator section errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.8
stmnPMThresholdRSSESValueThe threshold for the count of regenerator section severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.9
stmnPMThresholdRSOFSValueThe threshold for the count of regenerator section out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.10
stmnPMThresholdMSEBValueThe threshold for the count of multiplex section errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.11
stmnPMThresholdMSBBEValueThe threshold for the count of multiplex section background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.12
stmnPMThresholdMSESValueThe threshold for the count of multiplex section errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.13
stmnPMThresholdMSSESValueThe threshold for the count of multiplex section severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.14
stmnPMThresholdMSUASValueThe threshold for the count of multiplex section unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.15
stmnPMThresholdOTUEBValueThe threshold for the count of OTU digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.16
stmnPMThresholdOTUBBEValueThe threshold for the count of OTU digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.17
stmnPMThresholdOTUESValueThe threshold for the count of OTU digital wrapper layer errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.18
stmnPMThresholdOTUSESValueThe threshold for the count of OTU digital wrapper layer severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.19
stmnPMThresholdOTUOFSValueThe threshold for the count of OTU digital wrapper layer out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.20
stmnPMThresholdUNCRCDWValueThe threshold for the count of uncorrectable codewords.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.23
stmnPMThresholdRSUASValueThe threshold for the count of regenerator section unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.24
stmnPMThresholdOTUUASValueThe threshold for the count of OTU digital wrapper layer unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.16.1.25
vcnCrntPMTableA table of current performance monitoring statistics collected for the SDH VC-N facilities on the NE.
SEQUENCE OF VcnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.17
vcnCrntPMEntryThe row entry object of the SDH VC-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given VC-N facility.
VcnCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.17.1
vcnCrntPMTypeIdxThe type of VC-N facility targeted for PMs.
VcnType
.1.3.6.1.4.1.18070.2.2.1.6.17.1.1
vcnCrntPMShelfIdxThe number of the shelf of the VC-N facility targeted for PMs.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.17.1.2
vcnCrntPMSlotIdxThe number of the slot of the VC-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.17.1.3
vcnCrntPMPortIdxThe number of the port on the circuit pack of the VC-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.17.1.4
vcnCrntPMIdxThe channel number of the VC-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.17.1.5
vcnCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.17.1.6
vcnCrntPMHPEBValueThe count of high order path errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.17.1.7
vcnCrntPMHPEBTimeStampThe date and time stamp of the high order path errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.17.1.8
vcnCrntPMHPEBValidityIndicates the validity of the provided high order path errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.17.1.9
vcnCrntPMHPBBEValueThe count of high order path background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.17.1.10
vcnCrntPMHPBBETimeStampThe date and time stamp of the high order path background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.17.1.11
vcnCrntPMHPBBEValidityIndicates the validity of the provided high order path background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.17.1.12
vcnCrntPMHPESValueThe count of high order path errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.17.1.13
vcnCrntPMHPESTimeStampThe date and time stamp of the high order path errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.17.1.14
vcnCrntPMHPESValidityIndicates the validity of the provided high order path errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.17.1.15
vcnCrntPMHPSESValueThe count of high order path severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.17.1.16
vcnCrntPMHPSESTimeStampThe date and time stamp of the high order path severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.17.1.17
vcnCrntPMHPSESValidityIndicates the validity of the provided high order path severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.17.1.18
vcnCrntPMHPUASValueThe count of high order path unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.17.1.19
vcnCrntPMHPUASTimeStampThe date and time stamp of the high order path unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.17.1.20
vcnCrntPMHPUASValidityIndicates the validity of the provided high order path unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.17.1.21
vcnCrntPMHPEBInitializeUsed to initialize the value of the vcnCrntPMHPEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.17.1.22
vcnCrntPMHPBBEInitializeUsed to initialize the value of the vcnCrntPMHPBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.17.1.23
vcnCrntPMHPESInitializeUsed to initialize the value of the vcnCrntPMHPESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.17.1.24
vcnCrntPMHPSESInitializeUsed to initialize the value of the vcnCrntPMHPSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.17.1.25
vcnCrntPMHPUASInitializeUsed to initialize the value of the vcnCrntPMHPUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.17.1.26
vcnHistPMTableA table of historical performance monitoring statistics collected for the SDH VC-N facilities on the NE.
SEQUENCE OF VcnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.18
vcnHistPMEntryThe row entry object of the SDH VC-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given VC-N facility.
VcnHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.18.1
vcnHistPMTypeIdxThe type of the VC-N facility targeted for PMs.
VcnType
.1.3.6.1.4.1.18070.2.2.1.6.18.1.1
vcnHistPMShelfIdxThe number of the shelf of the VC-N facility targeted for PMs.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.18.1.2
vcnHistPMSlotIdxThe number of the slot of the VC-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.18.1.3
vcnHistPMPortIdxThe number of the port on the circuit pack of the VC-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.18.1.4
vcnHistPMIdxThe channel number of the VC-N facility targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.18.1.5
vcnHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.18.1.6
vcnHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.18.1.7
vcnHistPMHPEBValueThe count of high order path errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.18.1.8
vcnHistPMHPEBTimeStampThe date and time stamp of the high order path errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.18.1.9
vcnHistPMHPEBValidityIndicates the validity of the provided high order path errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.18.1.10
vcnHistPMHPBBEValueThe count of high order path background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.18.1.11
vcnHistPMHPBBETimeStampThe date and time stamp of the high order path background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.18.1.12
vcnHistPMHPBBEValidityIndicates the validity of the provided high order path background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.18.1.13
vcnHistPMHPESValueThe count of high order path errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.18.1.14
vcnHistPMHPESTimeStampThe date and time stamp of the high order path errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.18.1.15
vcnHistPMHPESValidityIndicates the validity of the high order path errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.18.1.16
vcnHistPMHPSESValueThe count of high order path severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.18.1.17
vcnHistPMHPSESTimeStampThe date and time stamp of the high order path severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.18.1.18
vcnHistPMHPSESValidityIndicates the validity of the provided high order path severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.18.1.19
vcnHistPMHPUASValueThe count of high order path unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.18.1.20
vcnHistPMHPUASTimeStampThe date and time stamp of the high order path unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.18.1.21
vcnHistPMHPUASValidityIndicates the validity of the provided high order path unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.18.1.22
vcnHistPMHPEBInitializeUsed to initialize the value of the vcnHistPMHPEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.18.1.23
vcnHistPMHPBBEInitializeUsed to initialize the value of the vcnHistPMHPBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.18.1.24
vcnHistPMHPESInitializeUsed to initialize the value of the vcnHistPMHPESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.18.1.25
vcnHistPMHPSESInitializeUsed to initialize the value of the vcnHistPMHPSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.18.1.26
vcnHistPMHPUASInitializeUsed to initialize the value of the vcnHistPMHPUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.18.1.27
vcnPMThresholdByPortTableA table of threshold levels for performance monitoring counter values on SDH VC-N facilities, that are used in the generation of threshold crossing alerts. The VC-N threshold settings will be the same for all channels on a given STM-N facility port.
SEQUENCE OF VcnPMThresholdByPortEntry
.1.3.6.1.4.1.18070.2.2.1.6.19
vcnPMThresholdByPortEntryThe row entry object of the SDH STM-N performance monitoring threshold by port table. Each row of this table contains a set of PM thresholds for a given interval type that applies to all the VC-N channels on an STM-N facility port.
VcnPMThresholdByPortEntry
.1.3.6.1.4.1.18070.2.2.1.6.19.1
vcnPMThresholdByPortTypeIdxThe type of the VC-N facility targeted for PM thresholds.
VcnType
.1.3.6.1.4.1.18070.2.2.1.6.19.1.1
vcnPMThresholdByPortShelfIdxThe shelf number of the VC-N facilities targeted for PM thresholds.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.19.1.2
vcnPMThresholdByPortSlotIdxThe slot number of the VC-N facilities targeted for PM thresholds.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.19.1.3
vcnPMThresholdByPortIdxThe number of the port on the circuit pack of the VC-N facilities targeted for PM thresholds.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.19.1.4
vcnPMThresholdByPortIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.19.1.5
vcnPMThresholdByPortHPEBValueThe threshold for the count of high order path errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.19.1.6
vcnPMThresholdByPortHPBBEValueThe threshold for the count of high order path background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.19.1.7
vcnPMThresholdByPortHPESValueThe threshold for the count of high order path errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.19.1.8
vcnPMThresholdByPortHPSESValueThe threshold for the count of high order path severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.19.1.9
vcnPMThresholdByPortHPUASValueThe threshold for the count of high order path unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.19.1.10
geCrntPMTableA table of current performance monitoring statistics collected for the Gigabit Ethernet facilities on the NE.
SEQUENCE OF GeCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.20
geCrntPMEntryThe row entry object of the Gigabit Ethernet current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given Gigabit Ethernet facility.
GeCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.20.1
geCrntPMShelfIdxThe number of the shelf on which the GE facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.1
geCrntPMSlotIdxThe number of the slot within which the GE facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.20.1.2
geCrntPMPortIdxThe number of the port on the circuit pack on which the GE facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.20.1.3
geCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.20.1.4
geCrntPMOPRValueThe optical power received on the input of the GE facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.5
geCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.6
geCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.7
geCrntPMOPTValueThe optical power transmitted at the output of the GE facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.8
geCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.9
geCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.10
geCrntPMTempValueThe temperature measured on the GE facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.11
geCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.12
geCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.13
geCrntPMSupplyVoltageValueThe supply voltage measured on the GE facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.14
geCrntPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.15
geCrntPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.16
geCrntPMLBCValueThe laser bias current measured on the GE facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.17
geCrntPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.18
geCrntPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.19
geCrntPMCVValueThe count of Gigabit Ethernet 8B/10B coding violations.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.20
geCrntPMCVTimeStampThe date and time stamp of the GE coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.21
geCrntPMCVValidityIndicates the validity of the provided GE coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.22
geCrntPMESValueThe count of GE errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.23
geCrntPMESTimeStampThe date and time stamp of the GE errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.24
geCrntPMESValidityIndicates the validity of the provided GE errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.25
geCrntPMSESValueThe count of GE severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.26
geCrntPMSESTimeStampThe date and time stamp of the GE severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.27
geCrntPMSESValidityIndicates the validity of the provided GE severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.28
geCrntPMTFRCRXValueThe Gigabit Ethernet total received frame count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.29
geCrntPMTFRCRXTimeStampThe date and time stamp of the GE total received frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.30
geCrntPMTFRCRXValidityIndicates the validity of the provided GE total received frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.31
geCrntPMTFRCRXInitializeUsed to initialize the value of the geCrntPMTFRCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.32
geCrntPMTFRCTXValueThe Gigabit Ethernet total transmitted frame count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.33
geCrntPMTFRCTXTimeStampThe date and time stamp of the GE total transmitted frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.34
geCrntPMTFRCTXValidityIndicates the validity of the provided GE total transmitted frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.35
geCrntPMTFRCTXInitializeUsed to initialize the value of the geCrntPMTFRCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.36
geCrntPMFRDRValueThe count of Gigabit Ethernet discarded frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.37
geCrntPMFRDRTimeStampThe date and time stamp of the GE discarded frames value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.38
geCrntPMFRDRValidityIndicates the validity of the provided GE discarded frames value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.39
geCrntPMFCSEValueThe count of Gigabit Ethernet frame checksum errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.40
geCrntPMFCSETimeStampThe date and time stamp of the GE frame checksum errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.41
geCrntPMFCSEValidityIndicates the validity of the provided GE frame checksum errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.42
geCrntPMTBYCRXValueThe Gigabit Ethernet total received byte count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.43
geCrntPMTBYCRXTimeStampThe date and time stamp of the GE total received byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.44
geCrntPMTBYCRXValidityIndicates the validity of the provided GE total received byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.45
geCrntPMTBYCRXInitializeUsed to initialize the value of the geCrntPMTBYCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.46
geCrntPMTBYCTXValueThe Gigabit Ethernet total transmitted byte count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.47
geCrntPMTBYCTXTimeStampThe date and time stamp of the GE total transmitted byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.48
geCrntPMTBYCTXValidityIndicates the validity of the provided GE total transmitted byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.49
geCrntPMTBYCTXInitializeUsed to initialize the value of the geCrntPMTBYCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.50
geCrntPMBCSTValueThe total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.51
geCrntPMBCSTTimeStampThe date and time stamp of the broadcast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.52
geCrntPMBCSTValidityIndicates the validity of the provided broadcast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.53
geCrntPMBCSTInitializeUsed to initialize the value of the geCrntPMBCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.54
geCrntPMMCSTValueThe total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.55
geCrntPMMCSTTimeStampThe date and time stamp of the multicast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.56
geCrntPMMCSTValidityIndicates the validity of the provided multicast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.57
geCrntPMMCSTInitializeUsed to initialize the value of the geCrntPMMCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.58
geCrntPMSIZE64ValueThe total number of 64 byte frames received (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.59
geCrntPMSIZE64TimeStampThe date and time stamp of the count of 64-byte packets received.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.60
geCrntPMSIZE64ValidityIndicates the validity of the provided count of 64-byte packets packets received.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.61
geCrntPMSIZE64InitializeUsed to initialize the value of the geCrntPMSIZE64Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.62
geCrntPMSIZE65To127ValueThe total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.63
geCrntPMSIZE65To127TimeStampThe date and time stamp of the count of packets between 65 and 127 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.64
geCrntPMSIZE65To127ValidityIndicates the validity of the provided count of packets between 65 and 127 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.65
geCrntPMSIZE65To127InitializeUsed to initialize the value of the geCrntPMSIZE65To127Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.66
geCrntPMSIZE128To255ValueThe total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.67
geCrntPMSIZE128To255TimeStampThe date and time stamp of the count of packets between 128 and 255 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.68
geCrntPMSIZE128To255ValidityIndicates the validity of the provided count of packets between 128 and 255 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.69
geCrntPMSIZE128To255InitializeUsed to initialize the value of the geCrntPMSIZE128To255Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.70
geCrntPMSIZE256To511ValueThe total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.71
geCrntPMSIZE256To511TimeStampThe date and time stamp of the count of packets between 256 and 511 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.72
geCrntPMSIZE256To511ValidityIndicates the validity of the provided count of packets between 256 and 511 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.73
geCrntPMSIZE256To511InitializeUsed to initialize the value of the geCrntPMSIZE256To511Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.74
geCrntPMSIZE512To1023ValueThe total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.75
geCrntPMSIZE512To1023TimeStampThe date and time stamp of the count of packets between 512 and 1023 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.76
geCrntPMSIZE512To1023ValidityIndicates the validity of the provided count of packets between 512 and 1023 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.77
geCrntPMSIZE512To1023InitializeUsed to initialize the value of the geCrntPMSIZE512To1023Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.78
geCrntPMSIZE1024To1518ValueThe total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.79
geCrntPMSIZE1024To1518TimeStampThe date and time stamp of the count of packets between 1024 and 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.80
geCrntPMSIZE1024To1518ValidityIndicates the validity of the provided count of packets between 1024 and 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.81
geCrntPMSIZE1024To1518InitializeUsed to initialize the value of the geCrntPMSIZE1024To1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.82
geCrntPMSIZEOver1518ValueThe total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.83
geCrntPMSIZEOver1518TimeStampThe date and time stamp of the count of packets over 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.84
geCrntPMSIZEOver1518ValidityIndicates the validity of the provided count of packets over 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.85
geCrntPMSIZEOver1518InitializeUsed to initialize the value of the geCrntPMSIZEOver1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.86
geCrntPMTPFCRXValueThe Gigabit Ethernet total received pause frame count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.87
geCrntPMTPFCRXTimeStampThe date and time stamp of the GE total received pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.88
geCrntPMTPFCRXValidityIndicates the validity of the provided GE total received pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.89
geCrntPMTPFCRXInitializeUsed to initialize the value of the geCrntPMTPFCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.90
geCrntPMTPFCTXValueThe Gigabit Ethernet total transmitted pause frame count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.20.1.91
geCrntPMTPFCTXTimeStampThe date and time stamp of the GE total transmitted pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.92
geCrntPMTPFCTXValidityIndicates the validity of the provided GE total transmitted pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.93
geCrntPMTPFCTXInitializeUsed to initialize the value of the geCrntPMTPFCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.94
geCrntPMUSIZEValueThe total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.95
geCrntPMUSIZETimeStampThe date and time stamp of the count of undersized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.96
geCrntPMUSIZEValidityIndicates the validity of the provided count of undersized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.97
geCrntPMOSIZEValueThe total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.98
geCrntPMOSIZETimeStampThe date and time stamp of the count of oversized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.99
geCrntPMOSIZEValidityIndicates the validity of the provided count of oversized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.100
geCrntPMFRGTValueThe total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.101
geCrntPMFRGTTimeStampThe date and time stamp of the count of received packet fragments.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.102
geCrntPMFRGTValidityIndicates the validity of the provided count of received packet fragments.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.103
geCrntPMJABRValueThe total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.104
geCrntPMJABRTimeStampThe date and time stamp of the count of received jabbers.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.105
geCrntPMJABRValidityIndicates the validity of the provided count of received jabbers.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.106
geCrntPMCVInitializeUsed to initialize the value of the geCrntPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.107
geCrntPMESInitializeUsed to initialize the value of the geCrntPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.108
geCrntPMSESInitializeUsed to initialize the value of the geCrntPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.109
geCrntPMFCSEInitializeUsed to initialize the value of the geCrntPMFCSEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.110
geCrntPMFRDRInitializeUsed to initialize the value of the geCrntPMFRDRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.111
geCrntPMUSIZEInitializeUsed to initialize the value of the geCrntPMUSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.112
geCrntPMOSIZEInitializeUsed to initialize the value of the geCrntPMOSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.113
geCrntPMFRGTInitializeUsed to initialize the value of the geCrntPMFRGTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.114
geCrntPMJABRInitializeUsed to initialize the value of the geCrntPMJABRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.115
geCrntPMUASValueThe count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.20.1.116
geCrntPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.117
geCrntPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.118
geCrntPMUASInitializeUsed to initialize the value of the geCrntPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.119
geCrntPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.120
geCrntPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.121
geCrntPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.122
geCrntPMOPRMinInitializeUsed to initialize the value of the geCrntPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.123
geCrntPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.124
geCrntPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.125
geCrntPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.126
geCrntPMOPRMaxInitializeUsed to initialize the value of the geCrntPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.127
geCrntPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.128
geCrntPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.129
geCrntPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.130
geCrntPMOPRAvgInitializeUsed to initialize the value of the geCrntPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.131
geCrntPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.132
geCrntPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.133
geCrntPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.134
geCrntPMOPTMinInitializeUsed to initialize the value of the geCrntPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.135
geCrntPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.136
geCrntPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.137
geCrntPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.138
geCrntPMOPTMaxInitializeUsed to initialize the value of the geCrntPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.139
geCrntPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.20.1.140
geCrntPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.20.1.141
geCrntPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.20.1.142
geCrntPMOPTAvgInitializeUsed to initialize the value of the geCrntPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.20.1.143
geHistPMTableA table of historical performance monitoring statistics collected for the Gigabit Ethernet facilities on the NE.
SEQUENCE OF GeHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.21
geHistPMEntryThe row entry object of the Gigabit Ethernet historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given Gigabit Ethernet facility.
GeHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.21.1
geHistPMShelfIdxThe number of the shelf on which the GE facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.1
geHistPMSlotIdxThe number of the slot within which the GE facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.21.1.2
geHistPMPortIdxThe number of the port on the circuit pack on which the GE facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.21.1.3
geHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.21.1.4
geHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.21.1.5
geHistPMOPRValueThe optical power received on the input of the GE facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.6
geHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.7
geHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.8
geHistPMOPTValueThe optical power transmitted at the output of the GE facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.9
geHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.10
geHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.11
geHistPMTempValueThe temperature measured on the GE facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.12
geHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.13
geHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.14
geHistPMSupplyVoltageValueThe supply voltage measured on the GE facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.15
geHistPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.16
geHistPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.17
geHistPMLBCValueThe laser bias current measured on the GE facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.18
geHistPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.19
geHistPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.20
geHistPMCVValueThe count of Gigabit Ethernet 8B/10B coding violations.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.21
geHistPMCVTimeStampThe date and time stamp of the GE coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.22
geHistPMCVValidityIndicates the validity of the provided GE coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.23
geHistPMESValueThe count of GE errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.24
geHistPMESTimeStampThe date and time stamp of the GE errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.25
geHistPMESValidityIndicates the validity of the provided GE errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.26
geHistPMSESValueThe count of GE severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.27
geHistPMSESTimeStampThe date and time stamp of the GE severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.28
geHistPMSESValidityIndicates the validity of the provided GE severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.29
geHistPMTFRCRXValueThe Gigabit Ethernet total received byte count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.30
geHistPMTFRCRXTimeStampThe date and time stamp of the GE total received byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.31
geHistPMTFRCRXValidityIndicates the validity of the provided GE total received byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.32
geHistPMTFRCRXInitializeUsed to initialize the value of the geHistPMTBYCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.33
geHistPMTFRCTXValueThe Gigabit Ethernet total transmitted frame count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.34
geHistPMTFRCTXTimeStampThe date and time stamp of the GE total transmitted frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.35
geHistPMTFRCTXValidityIndicates the validity of the provided GE total transmitted frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.36
geHistPMTFRCTXInitializeUsed to initialize the value of the geHistPMTFRCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.37
geHistPMFRDRValueThe count of Gigabit Ethernet discarded frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.38
geHistPMFRDRTimeStampThe date and time stamp of the GE discarded frames value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.39
geHistPMFRDRValidityIndicates the validity of the provided GE discarded frames value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.40
geHistPMFCSEValueThe count of Gigabit Ethernet frame checksum errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.41
geHistPMFCSETimeStampThe date and time stamp of the GE frame checksum errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.42
geHistPMFCSEValidityIndicates the validity of the provided GE frame checksum errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.43
geHistPMTBYCRXValueThe Gigabit Ethernet total received byte count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.44
geHistPMTBYCRXTimeStampThe date and time stamp of the GE total received byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.45
geHistPMTBYCRXValidityIndicates the validity of the provided GE total received byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.46
geHistPMTBYCRXInitializeUsed to initialize the value of the geHistPMTBYCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.47
geHistPMTBYCTXValueThe Gigabit Ethernet total transmitted byte count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.48
geHistPMTBYCTXTimeStampThe date and time stamp of the GE total transmitted byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.49
geHistPMTBYCTXValidityIndicates the validity of the provided GE total transmitted byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.50
geHistPMTBYCTXInitializeUsed to initialize the value of the geHistPMTBYCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.51
geHistPMBCSTValueThe total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.52
geHistPMBCSTTimeStampThe date and time stamp of the broadcast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.53
geHistPMBCSTValidityIndicates the validity of the provided broadcast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.54
geHistPMBCSTInitializeUsed to initialize the value of the geHistPMBCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.55
geHistPMMCSTValueThe total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.56
geHistPMMCSTTimeStampThe date and time stamp of the multicast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.57
geHistPMMCSTValidityIndicates the validity of the provided multicast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.58
geHistPMMCSTInitializeUsed to initialize the value of the geHistPMMCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.59
geHistPMSIZE64ValueThe total number of 64 byte frames received (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.60
geHistPMSIZE64TimeStampThe date and time stamp of the count of 64-byte packets received.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.61
geHistPMSIZE64ValidityIndicates the validity of the provided count of 64-byte packets packets received.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.62
geHistPMSIZE64InitializeUsed to initialize the value of the geHistPMSIZE64Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.63
geHistPMSIZE65To127ValueThe total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.64
geHistPMSIZE65To127TimeStampThe date and time stamp of the count of packets between 65 and 127 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.65
geHistPMSIZE65To127ValidityIndicates the validity of the provided count of packets between 65 and 127 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.66
geHistPMSIZE65To127InitializeUsed to initialize the value of the geHistPMSIZE65To127Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.67
geHistPMSIZE128To255ValueThe total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.68
geHistPMSIZE128To255TimeStampThe date and time stamp of the count of packets between 128 and 255 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.69
geHistPMSIZE128To255ValidityIndicates the validity of the provided count of packets between 128 and 255 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.70
geHistPMSIZE128To255InitializeUsed to initialize the value of the geHistPMSIZE128To255Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.71
geHistPMSIZE256To511ValueThe total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.72
geHistPMSIZE256To511TimeStampThe date and time stamp of the count of packets between 256 and 511 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.73
geHistPMSIZE256To511ValidityIndicates the validity of the provided count of packets between 256 and 511 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.74
geHistPMSIZE256To511InitializeUsed to initialize the value of the geHistPMSIZE256To511Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.75
geHistPMSIZE512To1023ValueThe total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.76
geHistPMSIZE512To1023TimeStampThe date and time stamp of the count of packets between 512 and 1023 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.77
geHistPMSIZE512To1023ValidityIndicates the validity of the provided count of packets between 512 and 1023 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.78
geHistPMSIZE512To1023InitializeUsed to initialize the value of the geHistPMSIZE512To1023Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.79
geHistPMSIZE1024To1518ValueThe total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.80
geHistPMSIZE1024To1518TimeStampThe date and time stamp of the count of packets between 1024 and 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.81
geHistPMSIZE1024To1518ValidityIndicates the validity of the provided count of packets between 1024 and 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.82
geHistPMSIZE1024To1518InitializeUsed to initialize the value of the geHistPMSIZE1024To1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.83
geHistPMSIZEOver1518ValueThe total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.84
geHistPMSIZEOver1518TimeStampThe date and time stamp of the count of packets over 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.85
geHistPMSIZEOver1518ValidityIndicates the validity of the provided count of packets over 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.86
geHistPMSIZEOver1518InitializeUsed to initialize the value of the geHistPMSIZEOver1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.87
geHistPMTPFCRXValueThe Gigabit Ethernet total received pause frame count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.88
geHistPMTPFCRXTimeStampThe date and time stamp of the GE total received pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.89
geHistPMTPFCRXValidityIndicates the validity of the provided GE total received pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.90
geHistPMTPFCRXInitializeUsed to initialize the value of the geHistPMTPFCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.91
geHistPMTPFCTXValueThe Gigabit Ethernet total transmitted pause frame count.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.21.1.92
geHistPMTPFCTXTimeStampThe date and time stamp of the GE total transmitted pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.93
geHistPMTPFCTXValidityIndicates the validity of the provided GE total transmitted pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.94
geHistPMTPFCTXInitializeUsed to initialize the value of the geHistPMTPFCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.95
geHistPMUSIZEValueThe total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.96
geHistPMUSIZETimeStampThe date and time stamp of the count of undersized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.97
geHistPMUSIZEValidityIndicates the validity of the provided count of undersized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.98
geHistPMOSIZEValueThe total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.99
geHistPMOSIZETimeStampThe date and time stamp of the count of oversized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.100
geHistPMOSIZEValidityIndicates the validity of the provided count of oversized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.101
geHistPMFRGTValueThe total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.102
geHistPMFRGTTimeStampThe date and time stamp of the count of received packet fragments.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.103
geHistPMFRGTValidityIndicates the validity of the provided count of received packet fragments.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.104
geHistPMJABRValueThe total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.105
geHistPMJABRTimeStampThe date and time stamp of the count of received jabbers.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.106
geHistPMJABRValidityIndicates the validity of the provided count of received jabbers.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.107
geHistPMCVInitializeUsed to initialize the value of the geHistPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.108
geHistPMESInitializeUsed to initialize the value of the geHistPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.109
geHistPMSESInitializeUsed to initialize the value of the geHistPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.110
geHistPMFCSEInitializeUsed to initialize the value of the geHistPMFCSEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.111
geHistPMFRDRInitializeUsed to initialize the value of the geHistPMFRDRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.112
geHistPMUSIZEInitializeUsed to initialize the value of the geHistPMUSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.113
geHistPMOSIZEInitializeUsed to initialize the value of the geHistPMOSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.114
geHistPMFRGTInitializeUsed to initialize the value of the geHistPMFRGTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.115
geHistPMJABRInitializeUsed to initialize the value of the geHistPMJABRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.116
geHistPMUASValueThe count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.21.1.117
geHistPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.118
geHistPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.119
geHistPMUASInitializeUsed to initialize the value of the geHistPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.120
geHistPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.121
geHistPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.122
geHistPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.123
geHistPMOPRMinInitializeUsed to initialize the value of the geHistPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.124
geHistPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.125
geHistPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.126
geHistPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.127
geHistPMOPRMaxInitializeUsed to initialize the value of the geHistPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.128
geHistPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.129
geHistPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.130
geHistPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.131
geHistPMOPRAvgInitializeUsed to initialize the value of the geHistPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.132
geHistPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.133
geHistPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.134
geHistPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.135
geHistPMOPTMinInitializeUsed to initialize the value of the geHistPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.136
geHistPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.137
geHistPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.138
geHistPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.139
geHistPMOPTMaxInitializeUsed to initialize the value of the geHistPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.140
geHistPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.21.1.141
geHistPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.21.1.142
geHistPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.21.1.143
geHistPMOPTAvgInitializeUsed to initialize the value of the geHistPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.21.1.144
gePMThresholdTableA table of threshold levels for performance monitoring counter values on Gigabit Ethernet facilities, that are used in the generation of threshold crossing alerts.
SEQUENCE OF GePMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.22
gePMThresholdEntryThe row entry object of the Gigabit Ethernet performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual GE facility.
GePMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.22.1
gePMThresholdShelfIdxThe shelf number on which the Gigabit Ethernet facility targeted for PM thresholds is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.22.1.1
gePMThresholdSlotIdxThe slot number on which the Gigabit Ethernet facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.22.1.2
gePMThresholdPortIdxThe number of the port on the circuit pack on which the Gigabit Ethernet facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.22.1.3
gePMThresholdIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.22.1.4
gePMThresholdCVValueThe threshold for the count of Gigabit Ethernet 8B/10B coding violations.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.5
gePMThresholdESValueThe threshold for the count of Gigabit Ethernet errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.6
gePMThresholdSESValueThe threshold for the count of Gigabit Ethernet severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.7
gePMThresholdFRDRValueThe threshold for the count of Gigabit Ethernet discarded frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.8
gePMThresholdFCSEValueThe threshold for the count of Gigabit Ethernet frame check sum errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.9
gePMThresholdUSIZEValueThe threshold for the count of Gigabit Ethernet undersized frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.10
gePMThresholdOSIZEValueThe threshold for the count of Gigabit Ethernet oversized frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.11
gePMThresholdFRGTValueThe threshold for the count of Gigabit Ethernet frame fragments.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.12
gePMThresholdJABRValueThe threshold for the count of Gigabit Ethernet jabbers.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.13
gePMThresholdUASValueThe threshold for the count of Gigabit Ethernet unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.22.1.14
fcCrntPMTableA table of current performance monitoring statistics collected for the Fiber Channel facilities on the NE.
SEQUENCE OF FcCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.23
fcCrntPMEntryThe row entry object of the Fiber Channel current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given Fiber Channel facility.
FcCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.23.1
fcCrntPMShelfIdxThe number of the shelf on which the FC facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.1
fcCrntPMSlotIdxThe number of the slot within which the FC facility targeted for PMs is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.2
fcCrntPMPortIdxThe number of the port on the circuit pack on which the FC facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.23.1.3
fcCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.23.1.4
fcCrntPMOPRValueThe optical power received on the input of the FC facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.5
fcCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.6
fcCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.7
fcCrntPMOPTValueThe optical power transmitted at the output of the FC facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.8
fcCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.9
fcCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.10
fcCrntPMTempValueThe temperature measured on the FC facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.11
fcCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.12
fcCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.13
fcCrntPMSupplyVoltageValueThe supply voltage measured on the FC facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.14
fcCrntPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.15
fcCrntPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.16
fcCrntPMLBCValueThe laser bias current measured on the FC facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.17
fcCrntPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.18
fcCrntPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.19
fcCrntPMCVValueThe count of Fiber Channel coding violations.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.23.1.20
fcCrntPMCVTimeStampThe date and time stamp of the FC coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.21
fcCrntPMCVValidityIndicates the validity of the provided FC coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.22
fcCrntPMESValueThe count of FC errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.23.1.23
fcCrntPMESTimeStampThe date and time stamp of the FC errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.24
fcCrntPMESValidityIndicates the validity of the provided FC errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.25
fcCrntPMSESValueThe count of FC severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.23.1.26
fcCrntPMSESTimeStampThe date and time stamp of the FC severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.27
fcCrntPMSESValidityIndicates the validity of the provided FC severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.28
fcCrntPMCVInitializeUsed to initialize the value of the fcCrntPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.29
fcCrntPMESInitializeUsed to initialize the value of the fcCrntPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.30
fcCrntPMSESInitializeUsed to initialize the value of the fcCrntPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.31
fcCrntPMUASValueThe count of unavailable seconds. This object applies only to transciever ports provisioned for the fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.23.1.32
fcCrntPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.33
fcCrntPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.34
fcCrntPMUASInitializeUsed to initialize the value of the fcCrntPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.35
fcCrntPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.36
fcCrntPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.37
fcCrntPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.38
fcCrntPMOPRMinInitializeUsed to initialize the value of the fcCrntPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.39
fcCrntPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.40
fcCrntPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.41
fcCrntPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.42
fcCrntPMOPRMaxInitializeUsed to initialize the value of the fcCrntPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.43
fcCrntPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.44
fcCrntPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.45
fcCrntPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.46
fcCrntPMOPRAvgInitializeUsed to initialize the value of the fcCrntPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.47
fcCrntPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.48
fcCrntPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.49
fcCrntPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.50
fcCrntPMOPTMinInitializeUsed to initialize the value of the fcCrntPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.51
fcCrntPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.52
fcCrntPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.53
fcCrntPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.54
fcCrntPMOPTMaxInitializeUsed to initialize the value of the fcCrntPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.55
fcCrntPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.23.1.56
fcCrntPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.23.1.57
fcCrntPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.23.1.58
fcCrntPMOPTAvgInitializeUsed to initialize the value of the fcCrntPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.23.1.59
fcHistPMTableA table of historical performance monitoring statistics collected for the Fiber Channel facilities on the NE.
SEQUENCE OF FcHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.24
fcHistPMEntryThe row entry object of the Fiber Channel historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given Fiber Channel facility.
FcHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.24.1
fcHistPMShelfIdxThe number of the shelf on which the FC facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.1
fcHistPMSlotIdxThe number of the slot within which the FC facility targeted for PMs is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.2
fcHistPMPortIdxThe number of the port on the circuit pack on which the FC facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.24.1.3
fcHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.24.1.4
fcHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.24.1.5
fcHistPMOPRValueThe optical power received on the input of the FC facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.6
fcHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.7
fcHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.8
fcHistPMOPTValueThe optical power transmitted at the output of the FC facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.9
fcHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.10
fcHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.11
fcHistPMTempValueThe temperature measured on the FC facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.12
fcHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.13
fcHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.14
fcHistPMSupplyVoltageValueThe supply voltage measured on the FC facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.15
fcHistPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.16
fcHistPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.17
fcHistPMLBCValueThe laser bias current measured on the FC facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.18
fcHistPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.19
fcHistPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.20
fcHistPMCVValueThe count of Fiber Channel coding violations.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.24.1.21
fcHistPMCVTimeStampThe date and time stamp of the FC coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.22
fcHistPMCVValidityIndicates the validity of the provided FC coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.23
fcHistPMESValueThe count of FC errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.24.1.24
fcHistPMESTimeStampThe date and time stamp of the FC errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.25
fcHistPMESValidityIndicates the validity of the provided FC errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.26
fcHistPMSESValueThe count of FC severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.24.1.27
fcHistPMSESTimeStampThe date and time stamp of the FC severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.28
fcHistPMSESValidityIndicates the validity of the provided FC severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.29
fcHistPMCVInitializeUsed to initialize the value of the fcHistPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.30
fcHistPMESInitializeUsed to initialize the value of the fcHistPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.31
fcHistPMSESInitializeUsed to initialize the value of the fcHistPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.32
fcHistPMUASValueThe count of unavailable seconds. This object applies only to transciever ports provisioned for the fiber channel protocol.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.24.1.33
fcHistPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.34
fcHistPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.35
fcHistPMUASInitializeUsed to initialize the value of the fcHistPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.36
fcHistPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.37
fcHistPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.38
fcHistPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.39
fcHistPMOPRMinInitializeUsed to initialize the value of the fcHistPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.40
fcHistPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.41
fcHistPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.42
fcHistPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.43
fcHistPMOPRMaxInitializeUsed to initialize the value of the fcHistPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.44
fcHistPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.45
fcHistPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.46
fcHistPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.47
fcHistPMOPRAvgInitializeUsed to initialize the value of the fcHistPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.48
fcHistPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.49
fcHistPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.50
fcHistPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.51
fcHistPMOPTMinInitializeUsed to initialize the value of the fcHistPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.52
fcHistPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.53
fcHistPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.54
fcHistPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.55
fcHistPMOPTMaxInitializeUsed to initialize the value of the fcHistPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.56
fcHistPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.24.1.57
fcHistPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.24.1.58
fcHistPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.24.1.59
fcHistPMOPTAvgInitializeUsed to initialize the value of the fcHistPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.24.1.60
fcPMThresholdTableA table of threshold levels for performance monitoring counter values on Fiber Channel facilities, that are used in the generation of threshold crossing alerts.
SEQUENCE OF FcPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.25
fcPMThresholdEntryThe row entry object of the Fiber Channel performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual FC facility.
FcPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.25.1
fcPMThresholdShelfIdxThe shelf number on which the Fiber Channel facility targeted for PM thresholds is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.25.1.1
fcPMThresholdSlotIdxThe slot number on which the Fiber Channel facility targeted for PM thresholds is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.25.1.2
fcPMThresholdPortIdxThe number of the port on the circuit pack on which the Fiber Channel facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.25.1.3
fcPMThresholdIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.25.1.4
fcPMThresholdCVValueThe threshold for the count of Fiber Channel coding violations.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.25.1.5
fcPMThresholdESValueThe threshold for the count of Fiber Channel errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.25.1.6
fcPMThresholdSESValueThe threshold for the count of Fiber Channel severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.25.1.7
fcPMThresholdUASValueThe threshold for the count of Fiber Channel unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.25.1.8
ethL1IFCrntPMTableA table of current performance monitoring statistics collected for the Ethernet Layer 1 Interface facilities on the NE.
SEQUENCE OF EthL1IFCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.26
ethL1IFCrntPMEntryThe row entry object of the Ethernet Layer 1 Interface current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given Ethernet Layer 1 Interface facility.
EthL1IFCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.26.1
ethL1IFCrntPMShelfIdxThe number of the shelf on which the Ethernet Layer 1 facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.1
ethL1IFCrntPMSlotIdxThe number of the slot within which the Ethernet Layer 1 facility targeted for PMs is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.2
ethL1IFCrntPMPortTypeIdxThe type of Ethernet Layer 1 port targeted for PMs.
PvxL1PortType
.1.3.6.1.4.1.18070.2.2.1.6.26.1.3
ethL1IFCrntPMPortIdxThe number of the port of the identified type targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.26.1.4
ethL1IFCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.26.1.5
ethL1IFCrntPMOPRValueThe optical power received on the input of the Ethernet Layer 1 facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.6
ethL1IFCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.7
ethL1IFCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.8
ethL1IFCrntPMOPTValueThe optical power transmitted at the output of the Ethernet Layer 1 facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.9
ethL1IFCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.10
ethL1IFCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.11
ethL1IFCrntPMTempValueThe temperature measured on the Ethernet Layer 1 facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.12
ethL1IFCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.13
ethL1IFCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.14
ethL1IFCrntPMSupplyVoltageValueThe supply voltage measured on the Ethernet Layer 1 facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.15
ethL1IFCrntPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.16
ethL1IFCrntPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.17
ethL1IFCrntPMSupplyVoltage2ValueA second supply voltage value measured on the Ethernet Layer 1 facility port. This object is available only for XFP-equipped Ethernet Interface ports.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.18
ethL1IFCrntPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.19
ethL1IFCrntPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.20
ethL1IFCrntPMLBCValueThe laser bias current measured on the Ethernet Layer 1 facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.21
ethL1IFCrntPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.22
ethL1IFCrntPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.23
ethL1IFCrntPMCVValueThe count of 8B/10B coding violations. This object is only available on Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.24
ethL1IFCrntPMCVTimeStampThe date and time stamp of the coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.25
ethL1IFCrntPMCVValidityIndicates the validity of the provided coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.26
ethL1IFCrntPMCVInitializeUsed to initialize the value of the ethL1IFCrntPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.27
ethL1IFCrntPMINVBLKValueThe count of invalid blocks. This object is only available on 10 Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.28
ethL1IFCrntPMINVBLKTimeStampThe date and time stamp of the invalid blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.29
ethL1IFCrntPMINVBLKValidityIndicates the validity of the provided invalid blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.30
ethL1IFCrntPMINVBLKInitializeUsed to initialize the value of the ethL1IFCrntPMINVBLKValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.31
ethL1IFCrntPMESValueThe count of Ethernet Layer 1 errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.32
ethL1IFCrntPMESTimeStampThe date and time stamp of the Ethernet Layer 1 errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.33
ethL1IFCrntPMESValidityIndicates the validity of the provided Ethernet Layer 1 errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.34
ethL1IFCrntPMESInitializeUsed to initialize the value of the ethL1IFCrntPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.35
ethL1IFCrntPMSESValueThe count of Ethernet Layer 1 severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.36
ethL1IFCrntPMSESTimeStampThe date and time stamp of the Ethernet Layer 1 severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.37
ethL1IFCrntPMSESValidityIndicates the validity of the provided Ethernet Layer 1 severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.38
ethL1IFCrntPMSESInitializeUsed to initialize the value of the ethL1IFCrntPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.39
ethL1IFCrntPMOTUEBValueThe count of OTU digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.40
ethL1IFCrntPMOTUEBTimeStampThe date and time stamp of the OTU digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.41
ethL1IFCrntPMOTUEBValidityIndicates the validity of the provided OTU digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.42
ethL1IFCrntPMOTUEBInitializeUsed to initialize the value of the ethL1IFCrntPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.43
ethL1IFCrntPMOTUBBEValueThe count of OTU digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.44
ethL1IFCrntPMOTUBBETimeStampThe date and time stamp of the OTU digital wrapper layer background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.45
ethL1IFCrntPMOTUBBEValidityIndicates the validity of the provided OTU digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.46
ethL1IFCrntPMOTUBBEInitializeUsed to initialize the value of the ethL1IFCrntPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.47
ethL1IFCrntPMOTUESValueThe count of OTU digital wrapper layer errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.48
ethL1IFCrntPMOTUESTimeStampThe date and time stamp of the OTU digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.49
ethL1IFCrntPMOTUESValidityIndicates the validity of the provided OTU digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.50
ethL1IFCrntPMOTUESInitializeUsed to initialize the value of the ethL1IFCrntPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.51
ethL1IFCrntPMOTUSESValueThe count of OTU digital wrapper layer severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.52
ethL1IFCrntPMOTUSESTimeStampThe date and time stamp of the OTU digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.53
ethL1IFCrntPMOTUSESValidityIndicates the validity of the provided OTU digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.54
ethL1IFCrntPMOTUSESInitializeUsed to initialize the value of the ethL1IFCrntPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.55
ethL1IFCrntPMOTUOFSValueThe count of OTU digital wrapper layer out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.56
ethL1IFCrntPMOTUOFSTimeStampThe date and time stamp of the OTU digital wrapper layer out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.57
ethL1IFCrntPMOTUOFSValidityIndicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.58
ethL1IFCrntPMOTUOFSInitializeUsed to initialize the value of the ethL1IFCrntPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.59
ethL1IFCrntPMNBITCRValueThe count of the number of bits corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.60
ethL1IFCrntPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.61
ethL1IFCrntPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.62
ethL1IFCrntPMNBITCRInitializeUsed to initialize the value of the ethL1IFCrntPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.63
ethL1IFCrntPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.64
ethL1IFCrntPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.65
ethL1IFCrntPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.66
ethL1IFCrntPMNBYTCRInitializeUsed to initialize the value of the ethL1IFCrntPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.67
ethL1IFCrntPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.68
ethL1IFCrntPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.69
ethL1IFCrntPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.70
ethL1IFCrntPMUNCRCDWInitializeUsed to initialize the value of the ethL1IFCrntPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.71
ethL1IFCrntPMOTNBERValueThe instantaneous BER of the line port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.72
ethL1IFCrntPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.73
ethL1IFCrntPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.74
ethL1IFCrntPMOTNBERInitializeUsed to initialize the value of the ethL1IFCrntPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.75
ethL1IFCrntPMOTNAVGBERValueThe interval/average BER of the line port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.76
ethL1IFCrntPMOTNAVGBERTimeStampThe date and time stamp of the interval/average BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.77
ethL1IFCrntPMOTNAVGBERValidityIndicates the validity of the provided interval/average BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.78
ethL1IFCrntPMOTNAVGBERInitializeUsed to initialize the value of the ethL1IFCrntPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.79
ethL1IFCrntPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.26.1.80
ethL1IFCrntPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.81
ethL1IFCrntPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.82
ethL1IFCrntPMNBITCR64BitInitializeUsed to initialize the value of the ethL1IFCrntPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.83
ethL1IFCrntPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.26.1.84
ethL1IFCrntPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.85
ethL1IFCrntPMNBYTCR64BitValidityIndicates the validity of the provided 64-bit number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.86
ethL1IFCrntPMNBYTCR64BitInitializeUsed to initialize the value of the ethL1IFCrntPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.87
ethL1IFCrntPMUASValueThe count of unavailable seconds. This object is only available on Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.88
ethL1IFCrntPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.89
ethL1IFCrntPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.90
ethL1IFCrntPMUASInitializeUsed to initialize the value of the ethL1IFCrntPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.91
ethL1IFCrntPMOTUUASValueThe count of OTU digital wrapper layer unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.26.1.92
ethL1IFCrntPMOTUUASTimeStampThe date and time stamp of the OTU digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.93
ethL1IFCrntPMOTUUASValidityIndicates the validity of the provided OTU digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.94
ethL1IFCrntPMOTUUASInitializeUsed to initialize the value of the ethL1IFCrntPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.95
ethL1IFCrntPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.96
ethL1IFCrntPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.97
ethL1IFCrntPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.98
ethL1IFCrntPMOPRMinInitializeUsed to initialize the value of the ethL1IFCrntPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.99
ethL1IFCrntPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.100
ethL1IFCrntPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.101
ethL1IFCrntPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.102
ethL1IFCrntPMOPRMaxInitializeUsed to initialize the value of the ethL1IFCrntPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.103
ethL1IFCrntPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.104
ethL1IFCrntPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.105
ethL1IFCrntPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.106
ethL1IFCrntPMOPRAvgInitializeUsed to initialize the value of the ethL1IFCrntPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.107
ethL1IFCrntPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.108
ethL1IFCrntPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.109
ethL1IFCrntPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.110
ethL1IFCrntPMOPTMinInitializeUsed to initialize the value of the ethL1IFCrntPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.111
ethL1IFCrntPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.112
ethL1IFCrntPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.113
ethL1IFCrntPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.114
ethL1IFCrntPMOPTMaxInitializeUsed to initialize the value of the ethL1IFCrntPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.115
ethL1IFCrntPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.26.1.116
ethL1IFCrntPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.26.1.117
ethL1IFCrntPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.26.1.118
ethL1IFCrntPMOPTAvgInitializeUsed to initialize the value of the ethL1IFCrntPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.26.1.119
ethL1IFHistPMTableA table of historical performance monitoring statistics collected for the Ethernet Layer 1 Interface facilities on the NE.
SEQUENCE OF EthL1IFHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.27
ethL1IFHistPMEntryThe row entry object of the Ethernet Layer 1 Interface historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given Ethernet Layer 1 Interface facility.
EthL1IFHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.27.1
ethL1IFHistPMShelfIdxThe number of the shelf on which the Ethernet Layer 1 facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.1
ethL1IFHistPMSlotIdxThe number of the slot within which the Ethernet Layer 1 facility targeted for PMs is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.2
ethL1IFHistPMPortTypeIdxThe type of Ethernet Layer 1 port targeted for PMs.
PvxL1PortType
.1.3.6.1.4.1.18070.2.2.1.6.27.1.3
ethL1IFHistPMPortIdxThe number of the port of the identified type targeted for PMs.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.27.1.4
ethL1IFHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.27.1.5
ethL1IFHistPMIntervalIdxThe specific PM bin number. The range is 1..96 for 15-minute bins, and for 1-day historical bins, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.27.1.6
ethL1IFHistPMOPRValueThe optical power received on the input of the Ethernet Layer 1 facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.7
ethL1IFHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.8
ethL1IFHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.9
ethL1IFHistPMOPTValueThe optical power transmitted at the output of the Ethernet Layer 1 facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.10
ethL1IFHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.11
ethL1IFHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.12
ethL1IFHistPMTempValueThe temperature measured on the Ethernet Layer 1 facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.13
ethL1IFHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.14
ethL1IFHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.15
ethL1IFHistPMSupplyVoltageValueThe supply voltage measured on the Ethernet Layer 1 facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.16
ethL1IFHistPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.17
ethL1IFHistPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.18
ethL1IFHistPMSupplyVoltage2ValueA second supply voltage value measured on the Ethernet Layer 1 facility port. This object is available only for XFP-equipped Ethernet Interface ports.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.19
ethL1IFHistPMSupplyVoltage2TimeStampThe date and time stamp of the second supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.20
ethL1IFHistPMSupplyVoltage2ValidityIndicates the validity of the provided second supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.21
ethL1IFHistPMLBCValueThe laser bias current measured on the Ethernet Layer 1 facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.22
ethL1IFHistPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.23
ethL1IFHistPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.24
ethL1IFHistPMCVValueThe count of 8B/10B coding violations. This object is only available on Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.25
ethL1IFHistPMCVTimeStampThe date and time stamp of the coding violations value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.26
ethL1IFHistPMCVValidityIndicates the validity of the provided coding violations value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.27
ethL1IFHistPMCVInitializeUsed to initialize the value of the ethL1IFHistPMCVValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.28
ethL1IFHistPMINVBLKValueThe count of invalid blocks. This object is only available on 10 Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.29
ethL1IFHistPMINVBLKTimeStampThe date and time stamp of the invalid blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.30
ethL1IFHistPMINVBLKValidityIndicates the validity of the provided invalid blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.31
ethL1IFHistPMINVBLKInitializeUsed to initialize the value of the ethL1IFHistPMINVBLKValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.32
ethL1IFHistPMESValueThe count of Ethernet Layer 1 errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.33
ethL1IFHistPMESTimeStampThe date and time stamp of the Ethernet Layer 1 errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.34
ethL1IFHistPMESValidityIndicates the validity of the provided Ethernet Layer 1 errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.35
ethL1IFHistPMESInitializeUsed to initialize the value of the ethL1IFHistPMESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.36
ethL1IFHistPMSESValueThe count of Ethernet Layer 1 severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.37
ethL1IFHistPMSESTimeStampThe date and time stamp of the Ethernet Layer 1 severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.38
ethL1IFHistPMSESValidityIndicates the validity of the provided Ethernet Layer 1 severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.39
ethL1IFHistPMSESInitializeUsed to initialize the value of the ethL1IFHistPMSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.40
ethL1IFHistPMOTUEBValueThe count of OTU digital wrapper layer errored blocks.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.41
ethL1IFHistPMOTUEBTimeStampThe date and time stamp of the OTU digital wrapper layer errored blocks value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.42
ethL1IFHistPMOTUEBValidityIndicates the validity of the provided OTU digital wrapper layer errored blocks value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.43
ethL1IFHistPMOTUEBInitializeUsed to initialize the value of the ethL1IFHistPMOTUEBValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.44
ethL1IFHistPMOTUBBEValueThe count of OTU digital wrapper layer background block errors.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.45
ethL1IFHistPMOTUBBETimeStampThe date and time stamp of the OTU digital wrapper layer background block errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.46
ethL1IFHistPMOTUBBEValidityIndicates the validity of the provided OTU digital wrapper layer background block errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.47
ethL1IFHistPMOTUBBEInitializeUsed to initialize the value of the ethL1IFHistPMOTUBBEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.48
ethL1IFHistPMOTUESValueThe count of OTU digital wrapper layer errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.49
ethL1IFHistPMOTUESTimeStampThe date and time stamp of the OTU digital wrapper layer errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.50
ethL1IFHistPMOTUESValidityIndicates the validity of the provided OTU digital wrapper layer errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.51
ethL1IFHistPMOTUESInitializeUsed to initialize the value of the ethL1IFHistPMOTUESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.52
ethL1IFHistPMOTUSESValueThe count of OTU digital wrapper layer severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.53
ethL1IFHistPMOTUSESTimeStampThe date and time stamp of the OTU digital wrapper layer severely errored seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.54
ethL1IFHistPMOTUSESValidityIndicates the validity of the provided OTU digital wrapper layer severely errored seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.55
ethL1IFHistPMOTUSESInitializeUsed to initialize the value of the ethL1IFHistPMOTUSESValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.56
ethL1IFHistPMOTUOFSValueThe count of OTU digital wrapper layer out-of-frame seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.57
ethL1IFHistPMOTUOFSTimeStampThe date and time stamp of the OTU digital wrapper layer out-of-frame seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.58
ethL1IFHistPMOTUOFSValidityIndicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.59
ethL1IFHistPMOTUOFSInitializeUsed to initialize the value of the ethL1IFHistPMOTUOFSValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.60
ethL1IFHistPMNBITCRValueThe count of the number of bits corrected.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.61
ethL1IFHistPMNBITCRTimeStampThe date and time stamp of the number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.62
ethL1IFHistPMNBITCRValidityIndicates the validity of the provided number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.63
ethL1IFHistPMNBITCRInitializeUsed to initialize the value of the ethL1IFHistPMNBITCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.64
ethL1IFHistPMNBYTCRValueThe count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.65
ethL1IFHistPMNBYTCRTimeStampThe date and time stamp of the number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.66
ethL1IFHistPMNBYTCRValidityIndicates the validity of the provided number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.67
ethL1IFHistPMNBYTCRInitializeUsed to initialize the value of the ethL1IFHistPMNBYTCRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.68
ethL1IFHistPMUNCRCDWValueThe count of uncorrectable codewords. This object applies only to OC-192 line port provisioned for OTN line mapping.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.69
ethL1IFHistPMUNCRCDWTimeStampThe date and time stamp of the uncorrectable codewords value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.70
ethL1IFHistPMUNCRCDWValidityIndicates the validity of the provided uncorrectable codewords value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.71
ethL1IFHistPMUNCRCDWInitializeUsed to initialize the value of the ethL1IFHistPMUNCRCDWValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.72
ethL1IFHistPMOTNBERValueThe instantaneous BER of the line port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.73
ethL1IFHistPMOTNBERTimeStampThe date and time stamp of the instantaneous BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.74
ethL1IFHistPMOTNBERValidityIndicates the validity of the provided instantaneous BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.75
ethL1IFHistPMOTNBERInitializeUsed to initialize the value of the ethL1IFHistPMOTNBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.76
ethL1IFHistPMOTNAVGBERValueThe interval/average BER of the line port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.77
ethL1IFHistPMOTNAVGBERTimeStampThe date and time stamp of the interval/average BER.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.78
ethL1IFHistPMOTNAVGBERValidityIndicates the validity of the provided interval/average BER.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.79
ethL1IFHistPMOTNAVGBERInitializeUsed to initialize the value of the ethL1IFHistPMOTNAVGBERValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.80
ethL1IFHistPMNBITCR64BitValueThe 64-bit count of the number of bits corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.27.1.81
ethL1IFHistPMNBITCR64BitTimeStampThe date and time stamp of the 64-bit number of bits corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.82
ethL1IFHistPMNBITCR64BitValidityIndicates the validity of the provided 64-bit number of bits corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.83
ethL1IFHistPMNBITCR64BitInitializeUsed to initialize the value of the ethL1IFHistPMNBITCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.84
ethL1IFHistPMNBYTCR64BitValueThe 64-bit count of the number of bytes corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.27.1.85
ethL1IFHistPMNBYTCR64BitTimeStampThe date and time stamp of the 64-bit number of bytes corrected value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.86
ethL1IFHistPMNBYTCR64BitValidityIndicates the validity of the provided 64-bit number of bytes corrected value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.87
ethL1IFHistPMNBYTCR64BitInitializeUsed to initialize the value of the ethL1IFHistPMNBYTCR64BitValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.88
ethL1IFHistPMUASValueThe count of unavailable seconds. This object is only available on Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.89
ethL1IFHistPMUASTimeStampThe date and time stamp of the unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.90
ethL1IFHistPMUASValidityIndicates the validity of the provided unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.91
ethL1IFHistPMUASInitializeUsed to initialize the value of the ethL1IFHistPMUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.92
ethL1IFHistPMOTUUASValueThe count of OTU digital wrapper layer unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.27.1.93
ethL1IFHistPMOTUUASTimeStampThe date and time stamp of the OTU digital wrapper layer unavailable seconds value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.94
ethL1IFHistPMOTUUASValidityIndicates the validity of the provided OTU digital wrapper layer unavailable seconds value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.95
ethL1IFHistPMOTUUASInitializeUsed to initialize the value of the ethL1IFHistPMOTUUASValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.96
ethL1IFHistPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.97
ethL1IFHistPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.98
ethL1IFHistPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.99
ethL1IFHistPMOPRMinInitializeUsed to initialize the value of the ethL1IFHistPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.100
ethL1IFHistPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.101
ethL1IFHistPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.102
ethL1IFHistPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.103
ethL1IFHistPMOPRMaxInitializeUsed to initialize the value of the ethL1IFHistPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.104
ethL1IFHistPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.105
ethL1IFHistPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.106
ethL1IFHistPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.107
ethL1IFHistPMOPRAvgInitializeUsed to initialize the value of the ethL1IFHistPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.108
ethL1IFHistPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.109
ethL1IFHistPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.110
ethL1IFHistPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.111
ethL1IFHistPMOPTMinInitializeUsed to initialize the value of the ethL1IFHistPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.112
ethL1IFHistPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.113
ethL1IFHistPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.114
ethL1IFHistPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.115
ethL1IFHistPMOPTMaxInitializeUsed to initialize the value of the ethL1IFHistPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.116
ethL1IFHistPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.27.1.117
ethL1IFHistPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.27.1.118
ethL1IFHistPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.27.1.119
ethL1IFHistPMOPTAvgInitializeUsed to initialize the value of the ethL1IFHistPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.27.1.120
ethL1IFPMThresholdTableA table of threshold levels for performance monitoring counter values on Ethernet Layer 1 facilities, that are used in the generation of threshold crossing alerts.
SEQUENCE OF EthL1IFPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.28
ethL1IFPMThresholdEntryThe row entry object of the Ethernet Layer 1 performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual Ethernet Layer 1 facility.
EthL1IFPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.28.1
ethL1IFPMThresholdShelfIdxThe shelf number on which the Ethernet Layer 1 facility targeted for PM thresholds is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.28.1.1
ethL1IFPMThresholdSlotIdxThe slot number on which the Ethernet Layer 1 facility targeted for PM thresholds is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.28.1.2
ethL1IFPMThresholdPortTypeIdxThe type of Ethernet Layer 1 port targeted for PM thresholds.
PvxL1PortType
.1.3.6.1.4.1.18070.2.2.1.6.28.1.3
ethL1IFPMThresholdPortIdxThe number of the port of the identified type targeted for PM thresholds.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.28.1.4
ethL1IFPMThresholdIntervalTypeIdxThe type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.28.1.5
ethL1IFPMThresholdCVValueThe threshold for the count of 8B/10B coding violations. This object is only available on Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.6
ethL1IFPMThresholdINVBLKValueThe threshold for the count of invalid blocks. This object is only available on 10 Gigabit Ethernet ports.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.7
ethL1IFPMThresholdESValueThe threshold for the count of errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.8
ethL1IFPMThresholdSESValueThe threshold for the count of severely errored seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.9
ethL1IFPMThresholdOTUEBValueThe threshold for the count of errored blocks at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.10
ethL1IFPMThresholdOTUBBEValueThe threshold for the count of background block errors at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.11
ethL1IFPMThresholdOTUESValueThe threshold for the count of errored seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.12
ethL1IFPMThresholdOTUSESValueThe threshold for the count of severely errored seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.13
ethL1IFPMThresholdOTUOFSValueThe threshold for the count of out-of-frame seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.14
ethL1IFPMThresholdUNCRCDWValueThe threshold for the count of uncorrectable codewords.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.15
ethL1IFPMThresholdUASValueThe threshold for the count of unavailable seconds.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.16
ethL1IFPMThresholdOTUUASValueThe threshold for the count of unavailable seconds at the OTU digital wrapper layer.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.28.1.17
pvxL2IFCrntPMTableA table of current performance monitoring statistics collected for the PacketVX Layer2 interfaces on the NE.
SEQUENCE OF PvxL2IFCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.29
pvxL2IFCrntPMEntryThe row entry object of the PacketVX Layer 2 current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given PVX Layer 2 interface facility.
PvxL2IFCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.29.1
pvxL2IFCrntPMSwitchIdxThe identifier of the ethernet switch instance on which the Layer 2 Interface facilitiy is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.29.1.1
pvxL2IFCrntPMShelfIdxThe number of the shelf on which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the shelf number is 0.
INTEGER (0|1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.2
pvxL2IFCrntPMSlotIdxThe number of the slot within which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the slot number is 0.
INTEGER (0|1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.3
pvxL2IFCrntPMPortTypeIdxThe type of PacketVX port on which the Layer 2 Interface facility is provisioned.
PvxPortType
.1.3.6.1.4.1.18070.2.2.1.6.29.1.4
pvxL2IFCrntPMPortIdxThe number of the port of the identified type on which the PVX Layer 2 IF facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.29.1.5
pvxL2IFCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.29.1.6
pvxL2IFCrntPMTFRCRXValueThe total received frame count receieved on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.7
pvxL2IFCrntPMTFRCRXTimeStampThe date and time stamp of the total received frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.8
pvxL2IFCrntPMTFRCRXValidityIndicates the validity of the provided total received frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.9
pvxL2IFCrntPMTFRCRXInitializeUsed to initialize the value of the pvxL2IFCrntPMTFRCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.10
pvxL2IFCrntPMTFRCTXValueThe total transmitted frame count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.11
pvxL2IFCrntPMTFRCTXTimeStampThe date and time stamp of the total transmitted frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.12
pvxL2IFCrntPMTFRCTXValidityIndicates the validity of the provided total transmitted frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.13
pvxL2IFCrntPMTFRCTXInitializeUsed to initialize the value of the pvxL2IFCrntPMTFRCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.14
pvxL2IFCrntPMFRDRValueThe count of discarded frames on the interface.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.29.1.15
pvxL2IFCrntPMFRDRTimeStampThe date and time stamp of the discarded frames value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.16
pvxL2IFCrntPMFRDRValidityIndicates the validity of the provided discarded frames value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.17
pvxL2IFCrntPMFRDRInitializeUsed to initialize the value of the pvxL2IFCrntPMFRDRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.18
pvxL2IFCrntPMFCSEValueThe count of frame checksum errors on the interface.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.29.1.19
pvxL2IFCrntPMFCSETimeStampThe date and time stamp of the frame checksum errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.20
pvxL2IFCrntPMFCSEValidityIndicates the validity of the provided frame checksum errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.21
pvxL2IFCrntPMFCSEInitializeUsed to initialize the value of the pvxL2IFCrntPMFCSEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.22
pvxL2IFCrntPMTBYCRXValueThe total received byte count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.23
pvxL2IFCrntPMTBYCRXTimeStampThe date and time stamp of the total received byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.24
pvxL2IFCrntPMTBYCRXValidityIndicates the validity of the provided total received byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.25
pvxL2IFCrntPMTBYCRXInitializeUsed to initialize the value of the pvxL2IFCrntPMTBYCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.26
pvxL2IFCrntPMTBYCTXValueThe total transmitted byte count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.27
pvxL2IFCrntPMTBYCTXTimeStampThe date and time stamp of the total transmitted byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.28
pvxL2IFCrntPMTBYCTXValidityIndicates the validity of the provided Ftotal transmitted byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.29
pvxL2IFCrntPMTBYCTXInitializeUsed to initialize the value of the pvxL2IFCrntPMTBYCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.30
pvxL2IFCrntPMBCSTValueThe total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.31
pvxL2IFCrntPMBCSTTimeStampThe date and time stamp of the broadcast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.32
pvxL2IFCrntPMBCSTValidityIndicates the validity of the provided broadcast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.33
pvxL2IFCrntPMBCSTInitializeUsed to initialize the value of the pvxL2IFCrntPMBCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.34
pvxL2IFCrntPMMCSTValueThe total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.35
pvxL2IFCrntPMMCSTTimeStampThe date and time stamp of the multicast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.36
pvxL2IFCrntPMMCSTValidityIndicates the validity of the provided multicast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.37
pvxL2IFCrntPMMCSTInitializeUsed to initialize the value of the pvxL2IFCrntPMMCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.38
pvxL2IFCrntPMSIZE64ValueThe total number of 64 byte frames received (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.39
pvxL2IFCrntPMSIZE64TimeStampThe date and time stamp of the count of 64-byte packets received.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.40
pvxL2IFCrntPMSIZE64ValidityIndicates the validity of the provided count of 64-byte packets packets received.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.41
pvxL2IFCrntPMSIZE64InitializeUsed to initialize the value of the pvxL2IFCrntPMSIZE64Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.42
pvxL2IFCrntPMSIZE65To127ValueThe total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.43
pvxL2IFCrntPMSIZE65To127TimeStampThe date and time stamp of the count of packets between 65 and 127 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.44
pvxL2IFCrntPMSIZE65To127ValidityIndicates the validity of the provided count of packets between 65 and 127 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.45
pvxL2IFCrntPMSIZE65To127InitializeUsed to initialize the value of the pvxL2IFCrntPMSIZE65To127Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.46
pvxL2IFCrntPMSIZE128To255ValueThe total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.47
pvxL2IFCrntPMSIZE128To255TimeStampThe date and time stamp of the count of packets between 128 and 255 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.48
pvxL2IFCrntPMSIZE128To255ValidityIndicates the validity of the provided count of packets between 128 and 255 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.49
pvxL2IFCrntPMSIZE128To255InitializeUsed to initialize the value of the pvxL2IFCrntPMSIZE128To255Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.50
pvxL2IFCrntPMSIZE256To511ValueThe total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.51
pvxL2IFCrntPMSIZE256To511TimeStampThe date and time stamp of the count of packets between 256 and 511 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.52
pvxL2IFCrntPMSIZE256To511ValidityIndicates the validity of the provided count of packets between 256 and 511 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.53
pvxL2IFCrntPMSIZE256To511InitializeUsed to initialize the value of the pvxL2IFCrntPMSIZE256To511Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.54
pvxL2IFCrntPMSIZE512To1023ValueThe total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.55
pvxL2IFCrntPMSIZE512To1023TimeStampThe date and time stamp of the count of packets between 512 and 1023 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.56
pvxL2IFCrntPMSIZE512To1023ValidityIndicates the validity of the provided count of packets between 512 and 1023 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.57
pvxL2IFCrntPMSIZE512To1023InitializeUsed to initialize the value of the pvxL2IFCrntPMSIZE512To1023Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.58
pvxL2IFCrntPMSIZE1024To1518ValueThe total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.59
pvxL2IFCrntPMSIZE1024To1518TimeStampThe date and time stamp of the count of packets between 1024 and 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.60
pvxL2IFCrntPMSIZE1024To1518ValidityIndicates the validity of the provided count of packets between 1024 and 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.61
pvxL2IFCrntPMSIZE1024To1518InitializeUsed to initialize the value of the pvxL2IFCrntPMSIZE1024To1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.62
pvxL2IFCrntPMSIZEOver1518ValueThe total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.63
pvxL2IFCrntPMSIZEOver1518TimeStampThe date and time stamp of the count of packets over 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.64
pvxL2IFCrntPMSIZEOver1518ValidityIndicates the validity of the provided count of packets over 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.65
pvxL2IFCrntPMSIZEOver1518InitializeUsed to initialize the value of the pvxL2IFCrntPMSIZEOver1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.66
pvxL2IFCrntPMTPFCRXValueThe total received pause frame count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.67
pvxL2IFCrntPMTPFCRXTimeStampThe date and time stamp of the total received pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.68
pvxL2IFCrntPMTPFCRXValidityIndicates the validity of the provided total received pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.69
pvxL2IFCrntPMTPFCRXInitializeUsed to initialize the value of the pvxL2IFCrntPMTPFCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.70
pvxL2IFCrntPMTPFCTXValueThe total transmitted pause frame count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.29.1.71
pvxL2IFCrntPMTPFCTXTimeStampThe date and time stamp of the total transmitted pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.72
pvxL2IFCrntPMTPFCTXValidityIndicates the validity of the provided total transmitted pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.73
pvxL2IFCrntPMTPFCTXInitializeUsed to initialize the value of the pvxL2IFCrntPMTPFCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.74
pvxL2IFCrntPMUSIZEValueThe total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.29.1.75
pvxL2IFCrntPMUSIZETimeStampThe date and time stamp of the count of undersized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.76
pvxL2IFCrntPMUSIZEValidityIndicates the validity of the provided count of undersized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.77
pvxL2IFCrntPMUSIZEInitializeUsed to initialize the value of the pvxL2IFCrntPMUSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.78
pvxL2IFCrntPMOSIZEValueThe total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.29.1.79
pvxL2IFCrntPMOSIZETimeStampThe date and time stamp of the count of oversized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.80
pvxL2IFCrntPMOSIZEValidityIndicates the validity of the provided count of oversized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.81
pvxL2IFCrntPMOSIZEInitializeUsed to initialize the value of the pvxL2IFCrntPMOSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.82
pvxL2IFCrntPMFRGTValueThe total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.29.1.83
pvxL2IFCrntPMFRGTTimeStampThe date and time stamp of the count of received packet fragments.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.29.1.84
pvxL2IFCrntPMFRGTValidityIndicates the validity of the provided count of received packet fragments.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.29.1.85
pvxL2IFCrntPMFRGTInitializeUsed to initialize the value of the pvxL2IFCrntPMFRGTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.29.1.86
pvxL2IFHistPMTableA table of historical performance monitoring statistics collected for the PacketVX Layer2 interfaces on the NE.
SEQUENCE OF PvxL2IFHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.30
pvxL2IFHistPMEntryThe row entry object of the PacketVX Layer 2 historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given PVX Layer 2 interface facility.
PvxL2IFHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.30.1
pvxL2IFHistPMSwitchIdxThe identifier of the ethernet switch instance on which the Layer 2 Interface facilitiy is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.30.1.1
pvxL2IFHistPMShelfIdxThe number of the shelf on which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the shelf number is 0.
INTEGER (0|1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.2
pvxL2IFHistPMSlotIdxThe number of the slot within which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the slot number is 0.
INTEGER (0|1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.3
pvxL2IFHistPMPortTypeIdxThe type of PacketVX port on which the Layer 2 Interface facility is provisioned.
PvxPortType
.1.3.6.1.4.1.18070.2.2.1.6.30.1.4
pvxL2IFHistPMPortIdxThe number of the port of the identified type on which the PVX Layer 2 IF facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.30.1.5
pvxL2IFHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.30.1.6
pvxL2IFHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.30.1.7
pvxL2IFHistPMTFRCRXValueThe total received frame count receieved on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.8
pvxL2IFHistPMTFRCRXTimeStampThe date and time stamp of the total received frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.9
pvxL2IFHistPMTFRCRXValidityIndicates the validity of the provided total received frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.10
pvxL2IFHistPMTFRCRXInitializeUsed to initialize the value of the pvxL2IFHistPMTFRCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.11
pvxL2IFHistPMTFRCTXValueThe total transmitted frame count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.12
pvxL2IFHistPMTFRCTXTimeStampThe date and time stamp of the total transmitted frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.13
pvxL2IFHistPMTFRCTXValidityIndicates the validity of the provided total transmitted frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.14
pvxL2IFHistPMTFRCTXInitializeUsed to initialize the value of the pvxL2IFHistPMTFRCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.15
pvxL2IFHistPMFRDRValueThe count of discarded frames on the interface.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.30.1.16
pvxL2IFHistPMFRDRTimeStampThe date and time stamp of the discarded frames value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.17
pvxL2IFHistPMFRDRValidityIndicates the validity of the provided discarded frames value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.18
pvxL2IFHistPMFRDRInitializeUsed to initialize the value of the pvxL2IFHistPMFRDRValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.19
pvxL2IFHistPMFCSEValueThe count of frame checksum errors on the interface.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.30.1.20
pvxL2IFHistPMFCSETimeStampThe date and time stamp of the frame checksum errors value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.21
pvxL2IFHistPMFCSEValidityIndicates the validity of the provided frame checksum errors value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.22
pvxL2IFHistPMFCSEInitializeUsed to initialize the value of the pvxL2IFHistPMFCSEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.23
pvxL2IFHistPMTBYCRXValueThe total received byte count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.24
pvxL2IFHistPMTBYCRXTimeStampThe date and time stamp of the total received byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.25
pvxL2IFHistPMTBYCRXValidityIndicates the validity of the provided total received byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.26
pvxL2IFHistPMTBYCRXInitializeUsed to initialize the value of the pvxL2IFHistPMTBYCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.27
pvxL2IFHistPMTBYCTXValueThe total transmitted byte count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.28
pvxL2IFHistPMTBYCTXTimeStampThe date and time stamp of the total transmitted byte count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.29
pvxL2IFHistPMTBYCTXValidityIndicates the validity of the provided Ftotal transmitted byte count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.30
pvxL2IFHistPMTBYCTXInitializeUsed to initialize the value of the pvxL2IFHistPMTBYCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.31
pvxL2IFHistPMBCSTValueThe total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.32
pvxL2IFHistPMBCSTTimeStampThe date and time stamp of the broadcast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.33
pvxL2IFHistPMBCSTValidityIndicates the validity of the provided broadcast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.34
pvxL2IFHistPMBCSTInitializeUsed to initialize the value of the pvxL2IFHistPMBCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.35
pvxL2IFHistPMMCSTValueThe total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.36
pvxL2IFHistPMMCSTTimeStampThe date and time stamp of the multicast packets received count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.37
pvxL2IFHistPMMCSTValidityIndicates the validity of the provided multicast packets received count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.38
pvxL2IFHistPMMCSTInitializeUsed to initialize the value of the pvxL2IFHistPMMCSTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.39
pvxL2IFHistPMSIZE64ValueThe total number of 64 byte frames received (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.40
pvxL2IFHistPMSIZE64TimeStampThe date and time stamp of the count of 64-byte packets received.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.41
pvxL2IFHistPMSIZE64ValidityIndicates the validity of the provided count of 64-byte packets packets received.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.42
pvxL2IFHistPMSIZE64InitializeUsed to initialize the value of the pvxL2IFHistPMSIZE64Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.43
pvxL2IFHistPMSIZE65To127ValueThe total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.44
pvxL2IFHistPMSIZE65To127TimeStampThe date and time stamp of the count of packets between 65 and 127 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.45
pvxL2IFHistPMSIZE65To127ValidityIndicates the validity of the provided count of packets between 65 and 127 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.46
pvxL2IFHistPMSIZE65To127InitializeUsed to initialize the value of the pvxL2IFHistPMSIZE65To127Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.47
pvxL2IFHistPMSIZE128To255ValueThe total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.48
pvxL2IFHistPMSIZE128To255TimeStampThe date and time stamp of the count of packets between 128 and 255 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.49
pvxL2IFHistPMSIZE128To255ValidityIndicates the validity of the provided count of packets between 128 and 255 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.50
pvxL2IFHistPMSIZE128To255InitializeUsed to initialize the value of the pvxL2IFHistPMSIZE128To255Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.51
pvxL2IFHistPMSIZE256To511ValueThe total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.52
pvxL2IFHistPMSIZE256To511TimeStampThe date and time stamp of the count of packets between 256 and 511 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.53
pvxL2IFHistPMSIZE256To511ValidityIndicates the validity of the provided count of packets between 256 and 511 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.54
pvxL2IFHistPMSIZE256To511InitializeUsed to initialize the value of the pvxL2IFHistPMSIZE256To511Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.55
pvxL2IFHistPMSIZE512To1023ValueThe total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.56
pvxL2IFHistPMSIZE512To1023TimeStampThe date and time stamp of the count of packets between 512 and 1023 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.57
pvxL2IFHistPMSIZE512To1023ValidityIndicates the validity of the provided count of packets between 512 and 1023 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.58
pvxL2IFHistPMSIZE512To1023InitializeUsed to initialize the value of the pvxL2IFHistPMSIZE512To1023Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.59
pvxL2IFHistPMSIZE1024To1518ValueThe total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.60
pvxL2IFHistPMSIZE1024To1518TimeStampThe date and time stamp of the count of packets between 1024 and 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.61
pvxL2IFHistPMSIZE1024To1518ValidityIndicates the validity of the provided count of packets between 1024 and 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.62
pvxL2IFHistPMSIZE1024To1518InitializeUsed to initialize the value of the pvxL2IFHistPMSIZE1024To1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.63
pvxL2IFHistPMSIZEOver1518ValueThe total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets).ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.64
pvxL2IFHistPMSIZEOver1518TimeStampThe date and time stamp of the count of packets over 1518 bytes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.65
pvxL2IFHistPMSIZEOver1518ValidityIndicates the validity of the provided count of packets over 1518 bytes.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.66
pvxL2IFHistPMSIZEOver1518InitializeUsed to initialize the value of the pvxL2IFHistPMSIZEOver1518Value object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.67
pvxL2IFHistPMTPFCRXValueThe total received pause frame count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.68
pvxL2IFHistPMTPFCRXTimeStampThe date and time stamp of the total received pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.69
pvxL2IFHistPMTPFCRXValidityIndicates the validity of the provided total received pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.70
pvxL2IFHistPMTPFCRXInitializeUsed to initialize the value of the pvxL2IFHistPMTPFCRXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.71
pvxL2IFHistPMTPFCTXValueThe total transmitted pause frame count on the interface.ro
Unsigned64
.1.3.6.1.4.1.18070.2.2.1.6.30.1.72
pvxL2IFHistPMTPFCTXTimeStampThe date and time stamp of the total transmitted pause frame count value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.73
pvxL2IFHistPMTPFCTXValidityIndicates the validity of the provided total transmitted pause frame count value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.74
pvxL2IFHistPMTPFCTXInitializeUsed to initialize the value of the pvxL2IFHistPMTPFCTXValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.75
pvxL2IFHistPMUSIZEValueThe total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.30.1.76
pvxL2IFHistPMUSIZETimeStampThe date and time stamp of the count of undersized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.77
pvxL2IFHistPMUSIZEValidityIndicates the validity of the provided count of undersized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.78
pvxL2IFHistPMUSIZEInitializeUsed to initialize the value of the pvxL2IFHistPMUSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.79
pvxL2IFHistPMOSIZEValueThe total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.30.1.80
pvxL2IFHistPMOSIZETimeStampThe date and time stamp of the count of oversized packets.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.81
pvxL2IFHistPMOSIZEValidityIndicates the validity of the provided count of oversized packets.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.82
pvxL2IFHistPMOSIZEInitializeUsed to initialize the value of the pvxL2IFHistPMOSIZEValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.83
pvxL2IFHistPMFRGTValueThe total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.30.1.84
pvxL2IFHistPMFRGTTimeStampThe date and time stamp of the count of received packet fragments.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.30.1.85
pvxL2IFHistPMFRGTValidityIndicates the validity of the provided count of received packet fragments.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.30.1.86
pvxL2IFHistPMFRGTInitializeUsed to initialize the value of the pvxL2IFHistPMFRGTValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.30.1.87
pvxL2IFPMThresholdTableA table of threshold levels for performance monitoring counter values on PVX Layer 2 IF facilities, that are used in the generation of threshold crossing alerts.
SEQUENCE OF PvxL2IFPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.31
pvxL2IFPMThresholdEntryThe row entry object of the PacketVX Layer 2 Interface performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual PVX Layer 2 IF facility.
PvxL2IFPMThresholdEntry
.1.3.6.1.4.1.18070.2.2.1.6.31.1
pvxL2IFPMThresholdSwitchIdxThe identifier of the ethernet switch instance on which the Layer 2 Interface facilitiy is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.31.1.1
pvxL2IFPMThresholdShelfIdxThe number of the shelf on which the PVX Layer2 IF targeted for PM thresholds is provisioned. For LAG entities, the shelf number is 0.
INTEGER (0|1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.31.1.2
pvxL2IFPMThresholdSlotIdxThe number of the slot within which the PVX Layer2 IF targeted for PM thresholds is provisioned. For LAG entities, the slot number is 0.
INTEGER (0|1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.31.1.3
pvxL2IFPMThresholdPortTypeIdxThe type of PacketVX port on which the Layer 2 Interface facility is provisioned.
PvxPortType
.1.3.6.1.4.1.18070.2.2.1.6.31.1.4
pvxL2IFPMThresholdPortIdxThe number of the port of the identified type on which the PVX Layer 2 IF facility targeted for PM thresholds is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.31.1.5
pvxL2IFPMThresholdIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.31.1.6
pvxL2IFPMThresholdFRDRValueThe threshold for the count of discarded frames on the interface.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.31.1.7
pvxL2IFPMThresholdFCSEValueThe threshold for the count of frame checksum errors on the interface.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.31.1.8
pvxL2IFPMThresholdUSIZEValueThe threshold for the count of undersized frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.31.1.9
pvxL2IFPMThresholdOSIZEValueThe threshold for the count of oversized frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.31.1.10
pvxL2IFPMThresholdFRGTValueThe threshold for the count of fragmented frames.rw
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.6.31.1.11
briCrntPMTableA table of current performance monitoring statistics collected for the Bit Rate Independent (BRI) facilities on the NE.
SEQUENCE OF BriCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.38
briCrntPMEntryThe row entry object of the BRI current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given BRI facility.
BriCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.38.1
briCrntPMShelfIdxThe number of the shelf on which the BRI facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.1
briCrntPMSlotIdxThe number of the slot within which the BRI facility targeted for PMs is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.2
briCrntPMPortIdxThe number of the port on the circuit pack on which the BRI facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.38.1.3
briCrntPMIntervalTypeIdxThe type of BRI bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.38.1.4
briCrntPMOPRValueThe optical power received on the input of the BRI facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.5
briCrntPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.6
briCrntPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.7
briCrntPMOPTValueThe optical power transmitted at the output of the BRI facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.8
briCrntPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.9
briCrntPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.10
briCrntPMTempValueThe temperature measured on the BRI facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.11
briCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.12
briCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.13
briCrntPMSupplyVoltageValueThe supply voltage measured on the BRI facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.14
briCrntPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.15
briCrntPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.16
briCrntPMLBCValueThe laser bias current measured on the BRI facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.17
briCrntPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.18
briCrntPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.19
briCrntPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.20
briCrntPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.21
briCrntPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.22
briCrntPMOPRMinInitializeUsed to initialize the value of the briCrntPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.38.1.23
briCrntPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.24
briCrntPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.25
briCrntPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.26
briCrntPMOPRMaxInitializeUsed to initialize the value of the briCrntPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.38.1.27
briCrntPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.28
briCrntPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.29
briCrntPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.30
briCrntPMOPRAvgInitializeUsed to initialize the value of the briCrntPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.38.1.31
briCrntPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.32
briCrntPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.33
briCrntPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.34
briCrntPMOPTMinInitializeUsed to initialize the value of the briCrntPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.38.1.35
briCrntPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.36
briCrntPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.37
briCrntPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.38
briCrntPMOPTMaxInitializeUsed to initialize the value of the briCrntPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.38.1.39
briCrntPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.38.1.40
briCrntPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.38.1.41
briCrntPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.38.1.42
briCrntPMOPTAvgInitializeUsed to initialize the value of the briCrntPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.38.1.43
briHistPMTableA table of historical performance monitoring statistics collected for the Bit Rate Independent (BRI) facilities on the NE.
SEQUENCE OF BriHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.39
briHistPMEntryThe row entry object of the BRI historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given BRI facility.
BriHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.39.1
briHistPMShelfIdxThe number of the shelf on which the BRI facility targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.1
briHistPMSlotIdxThe number of the slot within which the BRI facility targeted for PMs is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.2
briHistPMPortIdxThe number of the port on the circuit pack on which the BRI facility targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.39.1.3
briHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.39.1.4
briHistPMIntervalIdxThe specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.39.1.5
briHistPMOPRValueThe optical power received on the input of the BRI facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.6
briHistPMOPRTimeStampThe date and time stamp of the optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.7
briHistPMOPRValidityIndicates the validity of the provided optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.8
briHistPMOPTValueThe optical power transmitted at the output of the BRI facility port.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.9
briHistPMOPTTimeStampThe date and time stamp of the optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.10
briHistPMOPTValidityIndicates the validity of the provided optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.11
briHistPMTempValueThe temperature measured on the BRI facility port.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.12
briHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.13
briHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.14
briHistPMSupplyVoltageValueThe supply voltage measured on the BRI facility port.ro
FixedX10 UNITS "mVolts/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.15
briHistPMSupplyVoltageTimeStampThe date and time stamp of the supply voltage value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.16
briHistPMSupplyVoltageValidityIndicates the validity of the provided supply voltage value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.17
briHistPMLBCValueThe laser bias current measured on the BRI facility port.ro
INTEGER (-32768..32767) UNITS "mAmp"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.18
briHistPMLBCTimeStampThe date and time stamp of the laser bias current value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.19
briHistPMLBCValidityIndicates the validity of the provided laser bias current value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.20
briHistPMOPRMinValueThe minimum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.21
briHistPMOPRMinTimeStampThe date and time stamp of the minimum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.22
briHistPMOPRMinValidityIndicates the validity of the provided minimum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.23
briHistPMOPRMinInitializeUsed to initialize the value of the briHistPMOPRMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.39.1.24
briHistPMOPRMaxValueThe maximum optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.25
briHistPMOPRMaxTimeStampThe date and time stamp of the maximum optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.26
briHistPMOPRMaxValidityIndicates the validity of the provided maximum optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.27
briHistPMOPRMaxInitializeUsed to initialize the value of the briHistPMOPRMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.39.1.28
briHistPMOPRAvgValueThe average optical power received on the input of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.29
briHistPMOPRAvgTimeStampThe date and time stamp of the average optical power received value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.30
briHistPMOPRAvgValidityIndicates the validity of the provided average optical power received value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.31
briHistPMOPRAvgInitializeUsed to initialize the value of the briHistPMOPRAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.39.1.32
briHistPMOPTMinValueThe minimum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.33
briHistPMOPTMinTimeStampThe date and time stamp of the minimum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.34
briHistPMOPTMinValidityIndicates the validity of the provided minimum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.35
briHistPMOPTMinInitializeUsed to initialize the value of the briHistPMOPTMinValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.39.1.36
briHistPMOPTMaxValueThe maximum optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.37
briHistPMOPTMaxTimeStampThe date and time stamp of the maximum optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.38
briHistPMOPTMaxValidityIndicates the validity of the provided maximum optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.39
briHistPMOPTMaxInitializeUsed to initialize the value of the briHistPMOPTMaxValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.39.1.40
briHistPMOPTAvgValueThe average optical power transmitted at the output of the transceiver.ro
FixedX10 UNITS "dBm/10"
.1.3.6.1.4.1.18070.2.2.1.6.39.1.41
briHistPMOPTAvgTimeStampThe date and time stamp of the average optical power transmitted value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.39.1.42
briHistPMOPTAvgValidityIndicates the validity of the provided average optical power transmitted value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.39.1.43
briHistPMOPTAvgInitializeUsed to initialize the value of the briHistPMOPTAvgValue object to 0.rw
InitializeCmd
.1.3.6.1.4.1.18070.2.2.1.6.39.1.44
cpCrntPMTableA table of current performance monitoring statistics collected for the circuit packs on the NE.
SEQUENCE OF CpCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.49
cpCrntPMEntryThe row entry object of the equipment current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given circuit pack.
CpCrntPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.49.1
cpCrntPMCpTypeIdxThe type of the circuit pack targeted for PM retrieval.
CpType
.1.3.6.1.4.1.18070.2.2.1.6.49.1.1
cpCrntPMShelfIdxThe number of the shelf on which the circuit pack targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.49.1.2
cpCrntPMSlotIdxThe number of the slot within which the circuit pack targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.49.1.3
cpCrntPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.49.1.4
cpCrntPMTempValueThe circuit pack temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.49.1.5
cpCrntPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.49.1.6
cpCrntPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.49.1.7
cpHistPMTableA table of historical performance monitoring statistics collected for the circuit packs on the NE.
SEQUENCE OF CpHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.50
cpHistPMEntryThe row entry object of the circuit pack historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given circuit pack.
CpHistPMEntry
.1.3.6.1.4.1.18070.2.2.1.6.50.1
cpHistPMCpTypeIdxThe type of the circuit pack targeted for PM retrieval.
CpType
.1.3.6.1.4.1.18070.2.2.1.6.50.1.1
cpHistPMShelfIdxThe number of the shelf on which the circuit pack targeted for PMs is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.6.50.1.2
cpHistPMSlotIdxThe number of the slot within which the circuit pack targeted for PMs is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.50.1.3
cpHistPMIntervalTypeIdxThe type of PM bin according to interval length.
PMIntervalType
.1.3.6.1.4.1.18070.2.2.1.6.50.1.4
cpHistPMIntervalIdxThe specific PM bin number. The range is 1..96 for 15-minute bins, and for 1-day historical bins, the value is 1.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.6.50.1.5
cpHistPMTempValueThe circuit pack temperature.ro
INTEGER (-32768..32767) UNITS "degrees Celsius"
.1.3.6.1.4.1.18070.2.2.1.6.50.1.6
cpHistPMTempTimeStampThe date and time stamp of the temperature value.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.6.50.1.7
cpHistPMTempValidityIndicates the validity of the provided temperature value.ro
PMValidity
.1.3.6.1.4.1.18070.2.2.1.6.50.1.8
conditions
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.7
notifObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.7.1
condDateAndTimeThis object is used in Trap messages to indicate the date and time at which the condition or alarm reported in the Trap message occurred.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.7.1.1
condReportTypeIndicates if this is a condition (non-alarmed) or an alarm. This object is used solely for reporting the condition report type in Trap messages.ro
CondReportType
.1.3.6.1.4.1.18070.2.2.1.7.1.2
condSeverityIndicates the severity of the condition or alarm. This object is used solely for reporting the condition severity in Trap messages.ro
CondSeverity
.1.3.6.1.4.1.18070.2.2.1.7.1.3
condServiceAffectingIndicates if the presence of this active condition or alarm impacts the ability of the equipment to provide service as expected. This object is used solely for reporting whether or not a condition is service affecting in Trap messages.ro
CondServiceAffecting
.1.3.6.1.4.1.18070.2.2.1.7.1.4
condDescriptionA textual decription of the condition or alarm. This object is used solely for reporting the condition description in Trap messages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.7.1.5
condObjectTypeIdentifies the type of managed object against which the condition or alarm is raised.ro
NotifObjectType
.1.3.6.1.4.1.18070.2.2.1.7.1.6
condCodeTypeThis object value uniquely identifies the type of condition or alarm that is raised.ro
NotifCodeType
.1.3.6.1.4.1.18070.2.2.1.7.1.7
actCondTableThis table lists all active conditions and alarms raised on the system.
SEQUENCE OF ActCondEntry
.1.3.6.1.4.1.18070.2.2.1.7.2
actCondEntryContains identifying and descriptive attributes for a single active condition or alarm raised on the network element.
ActCondEntry
.1.3.6.1.4.1.18070.2.2.1.7.2.1
actCondNotifIdxIdentifies the type of condition or alarm that is active by pointing to the NOTIFICATION-TYPE object that corresponds to the raising event of the condition or alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.7.2.1.1
actCondTableEntryIdxIdentifies the type of resource that is alarmed by pointing to the corresponding table entry object.
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.7.2.1.2
actCondInstanceIdxIdentifies the specific instance of the idenitifed resource type that is alarmed by providing instance data that applies to an instance of the table entry object type identified by actCondTableEntryIdx. The instance data portion of the OID is mapped to an OCTET string.
DisplayString
.1.3.6.1.4.1.18070.2.2.1.7.2.1.3
actCondReportTypeIndicates if the table entry is a condition (non-alarmed) or an alarm.ro
CondReportType
.1.3.6.1.4.1.18070.2.2.1.7.2.1.4
actCondDateAndTimeThe date and time that the condition or alarm reported in the trap message was raised.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.7.2.1.5
actCondSeverityIndicates how severe the condition or alarm is.ro
CondSeverity
.1.3.6.1.4.1.18070.2.2.1.7.2.1.6
actCondServiceAffectingIndicates if the presence of this active condition or alarm impacts the ability of the equipment to provide service as expected.ro
CondServiceAffecting
.1.3.6.1.4.1.18070.2.2.1.7.2.1.7
actCondDescriptionA textual decription of the condition or alarm.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.7.2.1.8
actCondObjectTypeIdentifies the type of managed object against which the condition or alarm is raised.ro
NotifObjectType
.1.3.6.1.4.1.18070.2.2.1.7.2.1.9
actCondCodeTypeThis object value uniquely identifies the type of condition or alarm that is raised.ro
NotifCodeType
.1.3.6.1.4.1.18070.2.2.1.7.2.1.10
actCondSummaryThis object summarizes the active alarm/condition status of the network element. The value of the object returned indicates the following status data: - noActiveConditions: there are no active alarms or conditions on the network element - nonAlarmedConditionsActive: there is one or more active conditions on the network element, but none are of alarmable severity - minorAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is minor - majorAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is major - criticalAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is criticalro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.7.3
actAlarmTableThis table lists all active alarms raised on the system.
SEQUENCE OF ActAlarmEntry
.1.3.6.1.4.1.18070.2.2.1.7.4
actAlarmEntryContains identifying and descriptive attributes for a single active alarm raised on the system.
ActAlarmEntry
.1.3.6.1.4.1.18070.2.2.1.7.4.1
actAlarmNotifIdxIdentifies the type of alarm that is active by pointing to the NOTIFICATION-TYPE object that corresponds to the raising event of the condition or alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.7.4.1.1
actAlarmTableEntryIdxIdentifies the type of resource that is alarmed by pointing to the corresponding table entry object.
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.7.4.1.2
actAlarmInstanceIdxIdentifies the specific instance of the idenitifed resource type that is alarmed by providing instance data that applies to an instance of the table entry object type identified by actAlarmTableEntryIdx. The instance data portion of the OID is mapped to an OCTET string.
DisplayString
.1.3.6.1.4.1.18070.2.2.1.7.4.1.3
actAlarmReportTypeIndicates if the table entry is an alarm.ro
CondReportType
.1.3.6.1.4.1.18070.2.2.1.7.4.1.4
actAlarmDateAndTimeThe date and time that the alarm reported in the trap message was raised.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.7.4.1.5
actAlarmSeverityIndicates how severe the alarm is.ro
CondSeverity
.1.3.6.1.4.1.18070.2.2.1.7.4.1.6
actAlarmServiceAffectingIndicates if the presence of this active alarm impacts the ability of the equipment to provide service as expected.ro
CondServiceAffecting
.1.3.6.1.4.1.18070.2.2.1.7.4.1.7
actAlarmDescriptionA textual decription of the alarm.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.7.4.1.8
actAlarmObjectTypeIdentifies the type of managed object against which the alarm is raised.ro
NotifObjectType
.1.3.6.1.4.1.18070.2.2.1.7.4.1.9
actAlarmCodeTypeThis object value uniquely identifies the type of alarm that is raised.ro
NotifCodeType
.1.3.6.1.4.1.18070.2.2.1.7.4.1.10
administration
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.8
tl1UserTableThis table contains one row for every provisioned user that can operate the TL1 management interface on the NE. Each row contains a list of attributes that pertain to a provisioned TL1 user.
SEQUENCE OF Tl1UserEntry
.1.3.6.1.4.1.18070.2.2.1.8.1
tl1UserEntryThe conceptual row object of the TL1 user table.
Tl1UserEntry
.1.3.6.1.4.1.18070.2.2.1.8.1.1
tl1UserIdxThis is the unique user identifier, or UID, that is used for TL1 access.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.8.1.1.1
tl1IpLockoutAddrThis is an IP address from which TL1 user login attempts have been temporarily disabled due to an excessive number of failed user login attempts.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.8.2
tl1LogTableThis table lists all the log entries generated by the TL1 interface on the BTI 7000 system.
SEQUENCE OF Tl1LogEntry
.1.3.6.1.4.1.18070.2.2.1.8.3
tl1LogEntryThe conceptual row object of the TL1 log table.
Tl1LogEntry
.1.3.6.1.4.1.18070.2.2.1.8.3.1
tl1LogIdxThe unique identifier for this log entry. It is the global Log Id of the entry when viewed through the TL1 interface.
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.8.3.1.1
tl1LogSysNameThe name of the BTI 7000 system at the time that the log was recorded.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.8.3.1.2
tl1LogTypeThe type of log entry.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.8.3.1.3
tl1LogTypeSpecificLogNumThe type-specific number for this log.ro
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.8.3.1.4
tl1LogMsgCodeThe message code that was issued for this log entry. This field is relevant to log entries for TL1 autonomous notifications. For example, the message code may be 'REPT ALM OC48'. A message code is reported for all log entries of type alarm, event and dbChange. For logs of type security or command, the message code is an empty string.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.8.3.1.5
tl1LogDateAndTimeThe timestamp of the log entry.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.8.3.1.6
tl1LogMessageThis is the main log entry contents. The log entry is enclosed in double quotations.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.8.3.1.7
latestTl1LogNumIdentifies the value of the tl1LogIdx object for the most recently added entry in the tl1LogTable.ro
Unsigned32
.1.3.6.1.4.1.18070.2.2.1.8.4
snmpTrapRcvTableThis table contains one row for every configured SNMP trap receiver. Each row contains a list of attributes that pertain to a provisioned trap receiver. All access to this table, whether for read, write, or create requests are restricted to SNMP requests issued with a valid community string configured with read-write access.
SEQUENCE OF SnmpTrapRcvEntry
.1.3.6.1.4.1.18070.2.2.1.8.5
snmpTrapRcvEntryThe conceptual row object of the SNMP trap receiver table.
SnmpTrapRcvEntry
.1.3.6.1.4.1.18070.2.2.1.8.5.1
snmpTrapRcvIdxThis string serves as a unique trap receiver Id and is used to index the table.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.8.5.1.1
snmpTrapRcvIPAddrThe IP address of the trap receiver. The setting of this object is mandatory when creating a new row.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.8.5.1.2
snmpTrapRcvPortThe port on the specified IP address of the trap receiver.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.8.5.1.3
snmpTrapRcvNotifTypeThe type of notification service to be provided to the trap receiver. The notification type can be configured as inform only if the message version specified for the snmpTrapRcvVersion object is snmpv2c.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.8.5.1.4
snmpTrapRcvVersionThe type of notification service to be provided to the trap receiver. The notification type can be configured as inform only if the message version specified for the snmpTrapRcvVersion object is snmpv2c. The setting of this object is mandatory when creating a new row.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.8.5.1.5
snmpTrapRcvCommunityThe community string inserted into the trap messages generated for this trap receiver. The setting of this object is mandatory when creating a new row.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.8.5.1.6
snmpTrapRcvTTLThe time-to-live for the trap receiver. When the trap receiver is created or this object is set, this object specifies how long the trap receiver is to be configured. When read, the value returned is the length of time remaining before the trap receiver is automatically deleted. The valid range for this object is 000-00 to 099-99. If this object is set to a value of 000-00, the trap receiver will never auto-delete.rw
HoursAndMinutes
.1.3.6.1.4.1.18070.2.2.1.8.5.1.7
snmpTrapRcvRowStatusUsed to control the addition and deletion of entries in the SNMP trap receiver table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.8.5.1.100
connections
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.9
xcvrXCTableThis table contains one row for every provisioned cross connection between optical transceiver facilities on wavelength translator, regenerator and manager circuit packs.
SEQUENCE OF XcvrXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.1
xcvrXCEntryThe conceptual row object of the optical transceiver cross connection table.
XcvrXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.1.1
xcvrXCSrcTypeIdxThe specific type of wavelength conversion function of the transceiver port that serves as the source port for the cross connection.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.9.1.1.1
xcvrXCSrcShelfIdxThe number of the shelf of the transceiver port that serves as the source port for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.1.1.2
xcvrXCSrcSlotIdxThe number of the slot of the transceiver port that serves as the source port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.1.1.3
xcvrXCSrcIdxThe number of the port of the transceiver port that serves as the source port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.1.1.4
xcvrXCDestTypeIdxThe specific type of wavelength conversion function of the transceiver port that serves as the destination port for the cross connection.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.9.1.1.5
xcvrXCDestShelfIdxThe number of the shelf of the transceiver port that serves as the destination port for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.1.1.6
xcvrXCDestSlotIdxThe number of the slot of the transceiver port that serves as the destination port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.1.1.7
xcvrXCDestIdxThe number of the port of the transceiver port that serves as the destination port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.1.1.8
xcvrXCTypeThe type of cross connection between the identified source and destination transceiver ports. This is a mandatory object when a row of the transceiver cross connect table is created. Only 1-way and 2-way cross-connections are supported on optical transceiver portsrw
XCType
.1.3.6.1.4.1.18070.2.2.1.9.1.1.9
xcvrXCRowStatusUsed to control the addition and deletion of entries in the transceiver cross connection table, which in turn controls the provisioning and de-provisioning of transceiver cross connections.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.9.1.1.100
vcgXCTableThis table contains one row for every provisioned cross connection between VCGs on Muxponder circuit packs.
SEQUENCE OF VcgXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.2
vcgXCEntryThe conceptual row object of the VCG cross connection table.
VcgXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.2.1
vcgXCSrcShelfIdxThe number of the shelf of the VCG entity that serves as the source port for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.2.1.1
vcgXCSrcSlotIdxThe number of the slot of the VCG entity that serves as the source port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.2
vcgXCSrcPortIdxThe number of the port of the VCG entity that serves as the source port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.3
vcgXCSrcIdxThe number of the VCG within the identified port that serves as the source port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.4
vcgXCDestShelfIdxThe number of the shelf of the VCG entity that serves as the destination port for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.2.1.5
vcgXCDestSlotIdxThe number of the slot of the VCG entity that serves as the destination port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.6
vcgXCDestPortIdxThe number of the port of the VCG entity that serves as the destination port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.7
vcgXCDestIdxThe number of the VCG within the identified port that serves as the destination port for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.8
vcgXCTypeThe type of cross connection between the identified source and destination VCG entities. This is a mandatory object when a row of the VCG cross connect table is created. Only 2-way and 2-way protected cross-connections are supported between VCGs.rw
XCType
.1.3.6.1.4.1.18070.2.2.1.9.2.1.9
vcgXCProtShelfNumThe number of the shelf of the VCG entity that serves as the protection port for the cross connection.rw
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.2.1.10
vcgXCProtSlotNumThe number of the slot of the VCG entity that serves as the protection port for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.11
vcgXCProtPortNumThe number of the port of the VCG entity that serves as the protection port for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.12
vcgXCProtNumThe number of the VCG within the identified port that serves as the protection port for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.2.1.13
vcgXCRowStatusUsed to control the addition and deletion of entries in the VCG cross connection table, which in turn controls the provisioning and de-provisioning of VCG cross connections.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.9.2.1.100
stsnXCTableThis table contains one row for every provisioned cross connection between SONET STS-N facilities on Muxponder circuit packs.
SEQUENCE OF StsnXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.3
stsnXCEntryThe conceptual row object of the STS-N cross connection table.
StsnXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.3.1
stsnXCStsnTypeIdxThe specific STS-N rate of the cross-connection.
StsnType
.1.3.6.1.4.1.18070.2.2.1.9.3.1.1
stsnXCSrcShelfIdxThe number of the shelf of the STS-N facility that serves as the source end-point for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.3.1.2
stsnXCSrcSlotIdxThe number of the slot of the STS-N facility that serves as the source end-point for the cross connection.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.3.1.3
stsnXCSrcPortIdxThe number of the port of the STS-N facility that serves as the source end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.3.1.4
stsnXCSrcIdxThe number of the STS-N within the identified port that serves as the source end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.3.1.5
stsnXCDestShelfIdxThe number of the shelf of the STS-N facility that serves as the destination end-point for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.3.1.6
stsnXCDestSlotIdxThe number of the slot of the STS-N entity that serves as the destination end-point for the cross connection.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.3.1.7
stsnXCDestPortIdxThe number of the port of the STS-N entity that serves as the destination end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.3.1.8
stsnXCDestIdxThe number of the STS-N within the identified port that serves as the destination end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.3.1.9
stsnXCTypeThe type of cross connection between the identified source and destination STS-N facilities. This is a mandatory object when a row of the STS-N cross connect table is created. Only 2-way cross-connections are supported between STS-Ns.rw
XCType
.1.3.6.1.4.1.18070.2.2.1.9.3.1.10
stsnXCProtTypeNumThe rate of the STS-N facility that serves as the protection end-point for the cross connection.rw
StsnType
.1.3.6.1.4.1.18070.2.2.1.9.3.1.11
stsnXCProtShelfNumThe number of the shelf of the STS-N entity that serves as the protection end-point for the cross connection.rw
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.3.1.12
stsnXCProtSlotNumThe number of the slot of the STS-N entity that serves as the protection end-point for the cross connection.rw
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.3.1.13
stsnXCProtPortNumThe number of the port of the STS-N entity that serves as the protection end-point for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.3.1.14
stsnXCProtNumThe number of the STS-N within the identified port that serves as the protection end-point for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.3.1.15
stsnXCRowStatusUsed to control the addition and deletion of entries in the STS-N cross connection table, which in turn controls the provisioning and de-provisioning of STS-N cross connections.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.9.3.1.100
vcnXCTableThis table contains one row for every provisioned cross connection between SDH VC-N facilities on Muxponder circuit packs.
SEQUENCE OF VcnXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.4
vcnXCEntryThe conceptual row object of the VC-N cross connection table.
VcnXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.4.1
vcnXCVcnTypeIdxThe specific rate of the VC-N cross-connection.
VcnType
.1.3.6.1.4.1.18070.2.2.1.9.4.1.1
vcnXCSrcShelfIdxThe number of the shelf of the VC-N facility that serves as the source end-point for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.4.1.2
vcnXCSrcSlotIdxThe number of the slot of the VC-N facility that serves as the source end-point for the cross connection.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.4.1.3
vcnXCSrcPortIdxThe number of the port of the VC-N facility that serves as the source end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.4.1.4
vcnXCSrcIdxThe number of the VC-N within the identified port that serves as the source end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.4.1.5
vcnXCDestShelfIdxThe number of the shelf of the VC-N facility that serves as the destination end-point for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.4.1.6
vcnXCDestSlotIdxThe number of the slot of the VC-N entity that serves as the destination end-point for the cross connection.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.4.1.7
vcnXCDestPortIdxThe number of the port of the VC-N entity that serves as the destination end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.4.1.8
vcnXCDestIdxThe number of the VC-N within the identified port that serves as the destination end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.4.1.9
vcnXCTypeThe type of cross connection between the identified source and destination VC-N facilities. This is a mandatory object when a row of the VC-N cross connect table is created. Only 2-way cross-connections are supported between VC-Ns.rw
XCType
.1.3.6.1.4.1.18070.2.2.1.9.4.1.10
vcnXCProtTypeNumThe rate of the VC-N facility that serves as the protection end-point for the cross connection.rw
VcnType
.1.3.6.1.4.1.18070.2.2.1.9.4.1.11
vcnXCProtShelfNumThe number of the shelf of the VC-N entity that serves as the protection end-point for the cross connection.rw
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.4.1.12
vcnXCProtSlotNumThe number of the slot of the VC-N entity that serves as the protection end-point for the cross connection.rw
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.4.1.13
vcnXCProtPortNumThe number of the port of the VC-N entity that serves as the protection end-point for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.4.1.14
vcnXCProtNumThe number of the VC-N within the identified port that serves as the protection end-point for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.4.1.15
vcnXCRowStatusUsed to control the addition and deletion of entries in the VC-N cross connection table, which in turn controls the provisioning and de-provisioning of VC-N cross connections.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.9.4.1.100
odunXCTableThis table contains one row for every provisioned cross connection between OTN ODU-N facilities on Muxponder circuit packs.
SEQUENCE OF OdunXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.5
odunXCEntryThe conceptual row object of the ODU-N cross connection table.
OdunXCEntry
.1.3.6.1.4.1.18070.2.2.1.9.5.1
odunXCOdunTypeIdxThe specific rate of the ODU-N cross-connection.
OdunType
.1.3.6.1.4.1.18070.2.2.1.9.5.1.1
odunXCSrcShelfIdxThe number of the shelf of the ODU-N facility that serves as the source end-point for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.5.1.2
odunXCSrcSlotIdxThe number of the slot of the ODU-N facility that serves as the source end-point for the cross connection.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.5.1.3
odunXCSrcPortIdxThe number of the port of the ODU-N facility that serves as the source end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.5.1.4
odunXCSrcIdxThe number of the ODU-N within the identified port that serves as the source end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.5.1.5
odunXCDestShelfIdxThe number of the shelf of the ODU-N facility that serves as the destination end-point for the cross connection.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.5.1.6
odunXCDestSlotIdxThe number of the slot of the ODU-N entity that serves as the destination end-point for the cross connection.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.5.1.7
odunXCDestPortIdxThe number of the port of the ODU-N entity that serves as the destination end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.5.1.8
odunXCDestIdxThe number of the ODU-N within the identified port that serves as the destination end-point for the cross connection.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.5.1.9
odunXCTypeThe type of cross connection between the identified source and destination ODU-N facilities. This is a mandatory object when a row of the ODU-N cross connect table is created. Only 2-way cross-connections are supported between ODU-Ns.rw
XCType
.1.3.6.1.4.1.18070.2.2.1.9.5.1.10
odunXCProtTypeNumThe rate of the ODU-N facility that serves as the protection end-point for the cross connection.rw
OdunType
.1.3.6.1.4.1.18070.2.2.1.9.5.1.11
odunXCProtShelfNumThe number of the shelf of the ODU-N entity that serves as the protection end-point for the cross connection.rw
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.9.5.1.12
odunXCProtSlotNumThe number of the slot of the ODU-N entity that serves as the protection end-point for the cross connection.rw
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.9.5.1.13
odunXCProtPortNumThe number of the port of the ODU-N entity that serves as the protection end-point for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.5.1.14
odunXCProtNumThe number of the ODU-N within the identified port that serves as the protection end-point for the cross connection.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.9.5.1.15
odunXCRowStatusUsed to control the addition and deletion of entries in the ODU-N cross connection table, which in turn controls the provisioning and de-provisioning of ODU-N cross connections.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.9.5.1.100
protection
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.10
xcvrProtGrpTableThis table contains one row for every provisioned protection group pairing between optical transceiver facilities on the wavelength translator, regenerator and manager cards.
SEQUENCE OF XcvrProtGrpEntry
.1.3.6.1.4.1.18070.2.2.1.10.1
xcvrProtGrpEntryThe conceptual row object of the optical transceiver protection group table.
XcvrProtGrpEntry
.1.3.6.1.4.1.18070.2.2.1.10.1.1
xcvrProtGrpWorkTypeIdxThe specific type of wavelength conversion function of the transceiver port that serves as the working port for the protection group.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.10.1.1.1
xcvrProtGrpWorkShelfIdxThe number of the shelf of the transceiver port that serves as the working port for the protection group.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.10.1.1.2
xcvrProtGrpWorkSlotIdxThe number of the slot of the transceiver port that serves as the working port for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.1.1.3
xcvrProtGrpWorkIdxThe number of the port of the transceiver port that serves as the working port for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.1.1.4
xcvrProtGrpProtTypeIdxThe specific type of wavelength conversion function of the transceiver port that serves as the protection port for the protection group.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.10.1.1.5
xcvrProtGrpProtShelfIdxThe number of the shelf of the transceiver port that serves as the protection port for the protection group.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.10.1.1.6
xcvrProtGrpProtSlotIdxThe number of the slot of the transceiver port that serves as the protection port for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.1.1.7
xcvrProtGrpProtIdxThe number of the port of the transceiver port that serves as the protection port for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.1.1.8
xcvrProtGrpIdTextual data recorded by the user to describe the provisioned transceiver protection group in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.10.1.1.9
xcvrProtGrpRowStatusUsed to control the addition and deletion of entries in the transceiver protection group table, which in turn controls provisioning and deprovisioning of optical transceiver protection groups.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.10.1.1.100
ocnProtGrpTableThis table contains one row for every provisioned protection group pairing between SONET OC-N facilities on Muxponder circuit packs.
SEQUENCE OF OcnProtGrpEntry
.1.3.6.1.4.1.18070.2.2.1.10.2
ocnProtGrpEntryThe conceptual row object of the OC-N facility protection group table.
OcnProtGrpEntry
.1.3.6.1.4.1.18070.2.2.1.10.2.1
ocnProtGrpWorkTypeIdxThe specific rate of the OC-N facility that serves as the working facility for the protection group. Currently, only OCN-N facilities that are OTU-N mapped are supported for protection grouping.
OcnType
.1.3.6.1.4.1.18070.2.2.1.10.2.1.1
ocnProtGrpWorkShelfIdxThe number of the shelf of the OC-N facility that serves as the working facility for the protection group.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.10.2.1.2
ocnProtGrpWorkSlotIdxThe number of the slot of the OC-N facility that serves as the working facility for the protection group.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.10.2.1.3
ocnProtGrpWorkPortIdxThe number of the port of the OC-N facility that serves as the working facility for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.2.1.4
ocnProtGrpProtTypeIdxThe specific rate of the OC-N facility that serves as the protection facility for the protection group. Currently, only OC-N facilities that are OTU-N mapped are supported for protection grouping.
OcnType
.1.3.6.1.4.1.18070.2.2.1.10.2.1.5
ocnProtGrpProtShelfIdxThe number of the shelf of the OC-N facility that serves as the protection facility for the protection group.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.10.2.1.6
ocnProtGrpProtSlotIdxThe number of the slot of the OC-N facility that serves as the protection facility for the protection group.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.10.2.1.7
ocnProtGrpProtPortIdxThe number of the port of the OC-N facility that serves as the protection facility for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.2.1.8
ocnProtGrpIdTextual data recorded by the user to describe the provisioned OC-N protection group in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.10.2.1.9
ocnProtGrpRowStatusUsed to control the addition and deletion of entries in the OC-N protection group table, which in turn controls provisioning and deprovisioning of OC-N facility protection groups.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.10.2.1.100
stmnProtGrpTableThis table contains one row for every provisioned protection group pairing between SDH STM-N facilities on Muxponder circuit packs.
SEQUENCE OF StmnProtGrpEntry
.1.3.6.1.4.1.18070.2.2.1.10.3
stmnProtGrpEntryThe conceptual row object of the STM-N facility protection group table.
StmnProtGrpEntry
.1.3.6.1.4.1.18070.2.2.1.10.3.1
stmnProtGrpWorkTypeIdxThe specific rate of the STM-N facility that serves as the working facility for the protection group. Currently, only STM-N facilities that are OTU-N mapped are supported for protection grouping.
StmnType
.1.3.6.1.4.1.18070.2.2.1.10.3.1.1
stmnProtGrpWorkShelfIdxThe number of the shelf of the STM-N facility that serves as the working facility for the protection group.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.10.3.1.2
stmnProtGrpWorkSlotIdxThe number of the slot of the STM-N facility that serves as the working facility for the protection group.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.10.3.1.3
stmnProtGrpWorkPortIdxThe number of the port of the STM-N facility that serves as the working facility for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.3.1.4
stmnProtGrpProtTypeIdxThe specific rate of the STM-N facility that serves as the protection facility for the protection group. Currently, only STM-N facilities that are OTU-N mapped are supported for protection grouping.
StmnType
.1.3.6.1.4.1.18070.2.2.1.10.3.1.5
stmnProtGrpProtShelfIdxThe number of the shelf of the STM-N facility that serves as the protection facility for the protection group.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.10.3.1.6
stmnProtGrpProtSlotIdxThe number of the slot of the STM-N facility that serves as the protection facility for the protection group.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.10.3.1.7
stmnProtGrpProtPortIdxThe number of the port of the STM-N facility that serves as the protection facility for the protection group.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.10.3.1.8
stmnProtGrpIdTextual data recorded by the user to describe the provisioned STM-N protection group in a manner useful to the user.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.10.3.1.9
stmnProtGrpRowStatusUsed to control the addition and deletion of entries in the STM-N protection group table, which in turn controls provisioning and deprovisioning of STM-N facility protection groups.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.10.3.1.100
operations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11
neOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.1
dbBackupAndRestore
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.1.1
dbBackupAndRestoreCmdThis object is used to activate the steps of a database backup or database restore operation. The description of the DbBackupAndRestoreCmd textual convention explains the usage of this object to perform these operations.rw
DbBackupAndRestoreCmd
.1.3.6.1.4.1.18070.2.2.1.11.1.1.1
dbBackupAndRestoreTypeThis object is used to indicate whether a local database, or a remote database is involved in the backup or restore operation that is being activated with the dbBackupAndRestoreCmd object, as explained in the DbBackupAndRestoreType textual convention.rw
DbBackupAndRestoreType
.1.3.6.1.4.1.18070.2.2.1.11.1.1.2
dbBackupAndRestoreAddressThe IP address of an ftp server which the NE database is backed up to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.11.1.1.3
dbBackupAndRestorePathThe directory path on the ftp server where where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.1.4
dbBackupAndRestoreFtpUserThe user identifier to be used on the ftp server where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.1.5
dbBackupAndRestoreFtpPswdThe password to be used on the ftp server where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.1.6
dbBackupAndRestoreCheckAlmThis object is used to indicate whether or not the system is to be checked for active alarms before proceding with a backup or restore operation. If set to yes, the requested action will not be performed if alarms are active on the system. If not specified in the same set request as the dbBackupAndRestoreCmd object, the value is defaulted to yes.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.1.1.7
dbBackupAndRestoreCheckSysNameThis object is used to indicate whether or not the system name of the NE targeted for a database restore operation against the system name embedded in the database backup file to be restored. If set to yes, the requested action will not be performed if system names do not match. If not specified in the same set request as the dbBackupAndRestoreCmd object, the value is defaulted to yes.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.1.1.8
dbBackupAndRestoreInvokeFilenameThe name of the database backup file that is to be used in a database restore operation. This object is set along with the dbBackupAndRestoreCmd object when it is set to invokeRestore, as a confirmation that the database that is to be restored is the correct database. In order for the invokeRestore command to proceed, the value set for this object must match the value of the dbBackupAndRestoreFilename object.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.1.9
dbBackupAndRestoreFilenameThe name of the database backup file that is present and ready to be restored. The value of this field is valid after the completion of the loadRestore command.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.1.10
dbBackupAndRestoreResultIndicates if the identified stage of the database backup and restore process has resulted in success or failure.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.1.1.11
swUpgrade
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.1.2
swUpgradeCmdThis object is used to activate the steps of a software upgrade procedure on the system. The description of the SwUpgradeCmd textual convention explains the usage of this object to perform these operations.rw
SwUpgradeCmd
.1.3.6.1.4.1.18070.2.2.1.11.1.2.1
swUpgradeAddressThe IP address of an ftp or sftp server from which the software load files for the upgrade are to be downloaded.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.11.1.2.2
swUpgradePathThe directory path on the upgrade load files ftp or sftp server where the software load files are found.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.2.3
swUpgradeFtpUserThe user identifier to be used on the ftp or sftp server from which the upgrade load is downloaded.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.2.4
swUpgradeFtpPswdThe password to be used on the ftp or sftp server from which the upgrade load is downloaded.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.2.5
swUpgradeInvokeRelNumThe release number of the software upgrade load that is targeted in a software upgrade invoke operation. This object must be set along with the swUpgradeCmd object when it is set to invokeUpgrade or invokeScpUpgrade, as a confirmation that the software load to be used in the upgrade is the correct load.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.2.6
swUpgradeCheckAlmThis object is used to indicate whether or not the system is to be checked for active alarms before proceding with a software upgrade operation. If set to yes, the requested action will not be performed if alarms are active on the system. If not specified in the same set request as the swUpgradeCmd object, the value is defaulted to yes.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.1.2.7
swUpgradeActiveRelNumThe release number of the software load that is installed on the system and is currently active.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.2.8
swUpgradeInactiveRelNumThe release number of the software load that is installed on the system and is currently inactive.ro
DisplayString
.1.3.6.1.4.1.18070.2.2.1.11.1.2.9
swUpgradeFileTransferTypeThis object is used to define the file transfer protocol used to retreive the load from a remote server. The default value is ftprw
SwUpgradeFileTransferType
.1.3.6.1.4.1.18070.2.2.1.11.1.2.10
shelfInvOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.2
slotInvOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.3
shelfOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.4
cpOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.5
cpRestartOpTableThis table contains one row for every provisioned restartable circuit pack on the NE to facilitate the performing of circuit pack restarts.
SEQUENCE OF CpRestartOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.5.1
cpRestartOpEntryThe conceptual row object of the circuit pack restart operation table.
CpRestartOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.5.1.1
cpRestartOpTypeIdxThe specific type of circuit pack targeted for the restart operation.
CpType
.1.3.6.1.4.1.18070.2.2.1.11.5.1.1.1
cpRestartOpShelfIdxThe number of the shelf on which the circuit pack targeted for the restart operation is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.5.1.1.2
cpRestartOpSlotIdxThe number of the slot in which the circuit pack targeted for the restart operation is provisioned. For ESI type circuit packs, the slot will be 0. For CCM type circuit packs, the slot can only be 1 or 2.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.5.1.1.3
cpRestartOpCmdUsed to perform a circuit pack restart operation as follows. - warmRestart causes a restart of the main processor only; traffic is not affected - coldRestart causes a full circuit pack restart, including data path - powerOn causes a circuit pack that has been powered down due to a high temperature or voltage event to power on. When this object is read, the value noOp is returned.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.5.1.1.4
oaOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.6
oaOOBRSDOpTableThis table contains one row for every provisioned optical amplifier on the NE that supports the Override Optical Back Reflection Shutdown operation.
SEQUENCE OF OaOOBRSDOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.6.1
oaOOBRSDOpEntryThe conceptual row object of the optical amplifier override optical back reflection shutdown operation table.
OaOOBRSDOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1
oaOOBRSDOpTypeIdxThe specific type of optical amplifier.
OaType
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.1
oaOOBRSDOpShelfIdxThe number of the shelf on which the optical amplifier targeted for the operation is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.2
oaOOBRSDOpSlotIdxThe number of the slot within which the optical amplifier facility targeted for the operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.3
oaOOBRSDOpIdxThe number of the port on the circuit pack on which the optical amplifier facility has been provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.4
oaOOBRSDOpCmdUsed to perform a Override Optical Back Reflection Shutdown operation when this object is set to overrideOBRSD. When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.5
oaOOBRSDOpTimerUsed to specify the time duration of an override back reflection shutdown operation. It is only valid to set the value of this object in the same set request as for the oaOOBRSDOpCmd object. Despite the indicated value range, the actual supported range is 20 to 600. The value 0 is returned when this object is read, even if an overrideOBRSD operation is in progress.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.6
dataCommsOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.7
dataCommsPingTableThis table contains one row for every provisioned circuit pack on the NE from which an IP ping request can be sent. This includes all SCP and OSC type packs.
SEQUENCE OF DataCommsPingEntry
.1.3.6.1.4.1.18070.2.2.1.11.7.1
dataCommsPingEntryThe conceptual row object of the data comms ping table.
DataCommsPingEntry
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1
dataCommsPingCpTypeIdxThis object is used to indicate the type of circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object.
CpType
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.1
dataCommsPingShelfIdxThis object is used to indicate the shelf number containing the circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.2
dataCommsPingSlotIdxThis object is used to indicate the slot number containing the circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.3
dataCommsPingCmdThis object is used to trigger a ping operation from an OSC or SCP circuit pack. The description of DataCommsPingCmd textual convention explains the usage of this object to perform the ping operation.rw
DataCommsPingCmd
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.4
dataCommsPingAddressThis object is used to indicate the IP Address which is the target of the ping operation to be conducted using the dataCommsPingCmd object.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.5
dataCommsPingNumAttemptsThis object is used to indicate how many ping attempts are to be made in the ping operation to be conducted using the dataCommsPingCmd object. The default is 3.rw
INTEGER ( 1..3 )
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.6
dataCommsPingNumSuccessesThis object is used to indicate how many ping trials attempted in the ping operation resulted in a successful ping completion.ro
INTEGER ( 0..3 )
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.7
pluggableInvOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.8
pluggableInvRestartOpTableThis table contains one row for every provisioned restartable pluggable on a circuit pack.
SEQUENCE OF PluggableInvRestartOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.8.1
pluggableInvRestartOpEntryThe conceptual row object of the pluggable restart operation table.
PluggableInvRestartOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.8.1.1
pluggableInvRestartOpTypeIdxThe type of small form-factor pluggable inventory item targeted for the restart operation.
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.8.1.1.1
pluggableInvRestartOpShelfIdxThe number of the shelf on which the pluggable inventory item resides targeted for the restart operation is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.8.1.1.2
pluggableInvRestartOpSlotIdxThe number of the slot that contains the pluggable inventory item targeted for the restart operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.8.1.1.3
pluggableInvRestartOpPortIdxThe number of the port on the circuit pack that contains the pluggable inventory item.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.8.1.1.4
pluggableInvRestartOpCmdUsed to perform a restart operation as follows. - coldRestart causes a pluggable restart When this object is read, the value noOp is returned.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.8.1.1.5
xcvrOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.9
xcvrLpbkOpTableThis table contains one row for every provisioned optical transceiver on the NE to facilitate the performing of transceiver loopback operations.
SEQUENCE OF XcvrLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.9.1
xcvrLpbkOpEntryThe conceptual row object of the optical transceiver loopback operation table.
XcvrLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.9.1.1
xcvrLpbkOpTypeIdxThe specific type of wavelength conversion function of the circuit pack of the transceiver port targeted for the loopback operation.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.11.9.1.1.1
xcvrLpbkOpShelfIdxThe number of the shelf of the transceiver targeted for the loopback operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.9.1.1.2
xcvrLpbkOpSlotIdxThe number of the slot in which the transceiver targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.9.1.1.3
xcvrLpbkOpIdxThe number of the port on the circuit pack on which the optical transceiver facility has been provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.9.1.1.4
xcvrLpbkOpCmdUsed to perform a loopback operation on a transceiver facility as follows: - oprLpbk: operates a loopback on the transceiver - rlsLpbk: causes a previously invoked loopback to be released - oprTermLpbk: operates a terminal loopback for the transceiver When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.9.1.1.5
xcvrProtSwOpTableThis table contains one row for every provisioned optical transceiver on the NE configured to be part of a protection group pair to facilitate the performing of transceiver protection switching operations.
SEQUENCE OF XcvrProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.9.2
xcvrProtSwOpEntryThe conceptual row object of the optical transceiver protection switching operation table.
XcvrProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1
xcvrProtSwOpTypeIdxThe specific type of wavelength conversion function of the circuit pack of the transceiver port targeted for the protection switching operation.
XcvrType
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1.1
xcvrProtSwOpShelfIdxThe number of the shelf of the transceiver targeted for the protection switching operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1.2
xcvrProtSwOpSlotIdxThe number of the slot within which the transceiver targeted for the protection switching operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1.3
xcvrProtSwOpIdxThe number of the port on the circuit pack on which the optical transceiver facility has been provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1.4
xcvrProtSwOpCmdUsed to perform a protection switch on a transceiver facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention.rw
ProtSwOpCmd
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1.5
adminOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.10
amdOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.11
ocnOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.12
ocnLpbkOpTableThis table contains one row for every provisioned OC-N facility on the NE to facilitate the performing loopback operations.
SEQUENCE OF OcnLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.12.1
ocnLpbkOpEntryThe conceptual row object of the OC-N loopback operation table.
OcnLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.12.1.1
ocnLpbkOpTypeIdxThe specific type of OC-N signal which is targeted for the loopback operation.
OcnType
.1.3.6.1.4.1.18070.2.2.1.11.12.1.1.1
ocnLpbkOpShelfIdxThe number of the shelf of the OC-N facility targeted for the loopback operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.12.1.1.2
ocnLpbkOpSlotIdxThe number of the slot in which the OC-N facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.12.1.1.3
ocnLpbkOpPortIdxThe number of the port on the circuit pack on which the OC-N facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.12.1.1.4
ocnLpbkOpCmdUsed to perform a loopback operation on a OC-N facility as follows: - oprFacilityLpbk: operates an OC-N facility loopback - oprTerminalLpbk: operates an OC-N terminal loopback - rlsLpbk: releases a previously invoked loopback Note that the terminal loopback can only be operated on a client OC-N facility. When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.12.1.1.5
ocnProtSwOpTableThis table contains one row for every provisioned SONET OC-N facility on the NE configured to be part of a protection group pair to facilitate the performing of OC-N line protection switching operations.
SEQUENCE OF OcnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.12.2
ocnProtSwOpEntryThe conceptual row object of the SONET OC-N facility protection switching operation table.
OcnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.12.2.1
ocnProtSwOpTypeIdxThe specific rate of OC-N facility targeted for the protection switching operation.
OcnType
.1.3.6.1.4.1.18070.2.2.1.11.12.2.1.1
ocnProtSwOpShelfIdxThe number of the shelf of the OC-N facility targeted for the protection switching operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.12.2.1.2
ocnProtSwOpSlotIdxThe number of the slot within which the OC-N facility targeted for the protection switching operation is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.11.12.2.1.3
ocnProtSwOpIdxThe number of the port on the circuit pack on which the OC-N facility has been provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.12.2.1.4
ocnProtSwOpCmdUsed to perform a protection switch on a OC-N facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention.rw
ProtSwOpCmd
.1.3.6.1.4.1.18070.2.2.1.11.12.2.1.5
stsnOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.13
stsnProtSwOpTableThis table contains one row for every created SONET STS-N facility on the system which is part of a protection group pairing to facilitate the performing of STS-N protection switching operations.
SEQUENCE OF StsnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.13.1
stsnProtSwOpEntryThe conceptual row object of the SONET STS-N protection switching operation table.
StsnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.13.1.1
stsnProtSwOpTypeIdxThe specific type of STS-N signal targeted for the protection switching operation.
StsnType
.1.3.6.1.4.1.18070.2.2.1.11.13.1.1.1
stsnProtSwOpShelfIdxThe number of the shelf of the STS-N facility targeted for the protection switching operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.13.1.1.2
stsnProtSwOpSlotIdxThe number of the slot of the STS-N facility targeted for the protection switching operation.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.13.1.1.3
stsnProtSwOpPortIdxThe number of the port of the STS-N facility targeted for the protection switching operation.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.13.1.1.4
stsnProtSwOpIdxThe sts channel number of the STS-N facility targeted for the protection switching operation.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.13.1.1.5
stsnProtSwOpCmdUsed to perform a protection switch on a STS-N facility which is part of a protection group pairing, as described in the ProtSwOpCmd textual convention.rw
ProtSwOpCmd
.1.3.6.1.4.1.18070.2.2.1.11.13.1.1.6
stmnOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.14
stmnLpbkOpTableThis table contains one row for every provisioned STM-N facility on the NE to facilitate the performing of STM-N facility loopback operations.
SEQUENCE OF StmnLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.14.1
stmnLpbkOpEntryThe conceptual row object of the STM-N loopback operation table.
StmnLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.14.1.1
stmnLpbkOpTypeIdxThe specific type of STM-N signal which is targeted for the loopback operation.
StmnType
.1.3.6.1.4.1.18070.2.2.1.11.14.1.1.1
stmnLpbkOpShelfIdxThe number of the shelf of the STM-N facility targeted for the loopback operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.14.1.1.2
stmnLpbkOpSlotIdxThe number of the slot in which the STM-N facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.14.1.1.3
stmnLpbkOpPortIdxThe number of the port on the circuit pack on which the STM-N facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.14.1.1.4
stmnLpbkOpCmdUsed to perform a loopback operation on a STM-N facility as follows: - oprFacilityLpbk: operates an STM-N facility loopback - oprTerminalLpbk: operates an STM-N terminal loopback - rlsLpbk: releases a previously invoked loopback Note that a terminal loopback can only be operated on a client STM-N facility. When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.14.1.1.5
stmnProtSwOpTableThis table contains one row for every provisioned SDH STM-N facility on the NE configured to be part of a protection group pair to facilitate the performing of STM-N line protection switching operations.
SEQUENCE OF StmnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.14.2
stmnProtSwOpEntryThe conceptual row object of the SDH STM-N facility protection switching operation table.
StmnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.14.2.1
stmnProtSwOpTypeIdxThe specific rate of STM-N facility targeted for the protection switching operation.
StmnType
.1.3.6.1.4.1.18070.2.2.1.11.14.2.1.1
stmnProtSwOpShelfIdxThe number of the shelf of the STM-N faacility targeted for the protection switching operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.14.2.1.2
stmnProtSwOpSlotIdxThe number of the slot within which the STM-N facility targeted for the protection switching operation is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.11.14.2.1.3
stmnProtSwOpIdxThe number of the port on the circuit pack on which the STM-N facility has been provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.14.2.1.4
stmnProtSwOpCmdUsed to perform a protection switch on a STM-N facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention.rw
ProtSwOpCmd
.1.3.6.1.4.1.18070.2.2.1.11.14.2.1.5
vcnOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.15
vcnProtSwOpTableThis table contains one row for every created SDH VC-N facility on the system which is part of a protection group pairing to facilitate the performing of VC-N protection switching operations.
SEQUENCE OF VcnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.15.1
vcnProtSwOpEntryThe conceptual row object of the SDH VC-N protection switching operation table.
VcnProtSwOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1
vcnProtSwOpTypeIdxThe specific type of VC-N signal targeted for the protection switching operation.
VcnType
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.1
vcnProtSwOpShelfIdxThe number of the shelf of the VC-N facility targeted for the protection switching operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.2
vcnProtSwOpSlotIdxThe number of the slot of the VC-N facility targeted for the protection switching operation.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.3
vcnProtSwOpPortIdxThe number of the port of the VC-N facility targeted for the protection switching operation.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.4
vcnProtSwOpIdxThe index number of the VC-N facility targeted for the protection switching operation.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.5
vcnProtSwOpCmdUsed to perform a protection switch on a VC-N facility which is part of a protection group pairing, as described in the ProtSwOpCmd textual convention.rw
ProtSwOpCmd
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.6
geOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.16
geLpbkOpTableThis table contains one row for every provisioned Gigabit Ethernet facility on the NE to facilitate the performing of GE facility loopback operations.
SEQUENCE OF GeLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.16.1
geLpbkOpEntryThe conceptual row object of the Gigabit Ethernet loopback operation table.
GeLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.16.1.1
geLpbkOpShelfIdxThe number of the shelf of the Gigabit Ethernet facility targeted for the loopback operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.16.1.1.1
geLpbkOpSlotIdxThe number of the slot in which the Gigabit Ethernet facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.16.1.1.2
geLpbkOpPortIdxThe number of the port on the circuit pack on which the Gigabit Ethernet facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.16.1.1.3
geLpbkOpCmdUsed to perform a loopback operation on a Gigabit Ethernet facility as follows: - oprFacilityLpbk: operates an GE facility loopback - oprFacilityLpbk: operates an GE terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.16.1.1.4
fcOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.17
fcLpbkOpTableThis table contains one row for every provisioned Fiber Channel facility on the NE to facilitate the performing of FC facility loopback operations.
SEQUENCE OF FcLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.17.1
fcLpbkOpEntryThe conceptual row object of the Fiber Channel loopback operation table.
FcLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.17.1.1
fcLpbkOpShelfIdxThe number of the shelf of the Fiber Channel facility targeted for the loopback operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.17.1.1.1
fcLpbkOpSlotIdxThe number of the slot in which the Fiber Channel facility targeted for the loopback operation is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.11.17.1.1.2
fcLpbkOpPortIdxThe number of the port on the circuit pack on which the Fiber Channel facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.17.1.1.3
fcLpbkOpCmdUsed to perform a loopback operation on a Fiber Channel facility as follows: - oprFacilityLpbk: operates an FC facility loopback - oprFacilityLpbk: operates an FC terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.17.1.1.4
briOperations
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.11.18
briLpbkOpTableThis table contains one row for every provisioned Bit Rate Independent (BRI) facility on the NE to facilitate the performing of BRI facility loopback operations.
SEQUENCE OF BriLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.18.1
briLpbkOpEntryThe conceptual row object of the BRI loopback operation table.
BriLpbkOpEntry
.1.3.6.1.4.1.18070.2.2.1.11.18.1.1
briLpbkOpShelfIdxThe number of the shelf of the BRI facility targeted for the loopback operation.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.11.18.1.1.1
briLpbkOpSlotIdxThe number of the slot in which the BRI facility targeted for the loopback operation is provisioned.
INTEGER (1|3|5|7|9|11|13|15|17|19)
.1.3.6.1.4.1.18070.2.2.1.11.18.1.1.2
briLpbkOpPortIdxThe number of the port on the circuit pack on which the BRI facility targeted for the loopback operation is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.11.18.1.1.3
briLpbkOpCmdUsed to perform a loopback operation on a BRI facility as follows: - oprFacilityLpbk: operates a BRI facility loopback - oprFacilityLpbk: operates a BRI terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.11.18.1.1.4
synchronization
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.12
cpSynchronizationTableThis table contains one row for every provisioned circuit pack that supports SONET synchronization configuration.
SEQUENCE OF CpSynchronizationEntry
.1.3.6.1.4.1.18070.2.2.1.12.1
cpSynchronizationEntryThe conceptual row object of the circuit pack synchronization table.
CpSynchronizationEntry
.1.3.6.1.4.1.18070.2.2.1.12.1.1
cpSynchronizationTypeIdxThe specific type of circuit pack provisioned.
CpType
.1.3.6.1.4.1.18070.2.2.1.12.1.1.1
cpSynchronizationShelfIdxThe number of the shelf on which the circuit pack is provisioned.
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.12.1.1.2
cpSynchronizationSlotIdxThe number of the slot in which the circuit pack is provisioned.
INTEGER
.1.3.6.1.4.1.18070.2.2.1.12.1.1.3
cpSynchronizationTimingModeThe timing mode used for SONET synchronization on the pack.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.12.1.1.4
cpSynchronizationPrimRefSrcPortNumThe port number of the SONET facility that serves as the primary timing reference source. When the value is 0, the primary reference is not configured.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.12.1.1.5
cpSynchronizationPrimRefProtStatusThe protection status of the primary timing reference source.ro
ProtectionStatusType
.1.3.6.1.4.1.18070.2.2.1.12.1.1.6
cpSynchronizationPrimProtStatQlfrA textual list of qualifiers of the reported protection status of the primary timing reference source.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.12.1.1.7
cpSynchronizationSecRefSrcPortNumThe port number of the SONET facility that serves as the secondary timing reference source. When the value is 0, the secondary reference is not configured.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.12.1.1.8
cpSynchronizationSecRefProtStatusThe protection status of the secondary timing reference source.ro
ProtectionStatusType
.1.3.6.1.4.1.18070.2.2.1.12.1.1.9
cpSynchronizationSecProtStatQlfrA textual list of qualifiers of the reported protection status of the secondary timing reference source.ro
OperStatQlfr
.1.3.6.1.4.1.18070.2.2.1.12.1.1.10
cpSynchronizationPrimRefBasicSSMUsed to enable basic Synchronization Status Messaging (SSM) functionality on the primary timing reference source.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.12.1.1.11
cpSynchronizationSecRefBasicSSMUsed to enable basic Synchronization Status Messaging (SSM) functionality on the primary timing reference source.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.12.1.1.12
cpSynchronizationSwEvtTypeIndicates the type of timing reference switching event that has occurred on the circuit pack.ro
SyncSwEvtType
.1.3.6.1.4.1.18070.2.2.1.12.1.1.13
topology
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.13
networkNeighborTableThis table is used to store information on the network neighbors of the local network element. Each row contains information on a specific network neighbor.
SEQUENCE OF NetworkNeighborEntry
.1.3.6.1.4.1.18070.2.2.1.13.1
networkNeighborEntryThe conceptual row object of the network neighbor table.
NetworkNeighborEntry
.1.3.6.1.4.1.18070.2.2.1.13.1.1
networkNeighborIdxA textual identifier of the network neighbor.
DisplayString
.1.3.6.1.4.1.18070.2.2.1.13.1.1.1
networkNeighborIPAddrThe primary IP Address of the network neighbor.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.13.1.1.2
networkNeighborRowStatusUsed to control the addition and deletion of entries in the network neighbor table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.13.1.1.3
ospfGeneralTableThis table contains all of general OSPF parameters for the network element. The group can be created and deleted but only one entry can exist in the table.
SEQUENCE OF OspfGeneralGroupEntry
.1.3.6.1.4.1.18070.2.2.1.13.2
ospfGeneralGroupEntryThe list entry for the OSPF General Group parameters.
OspfGeneralGroupEntry
.1.3.6.1.4.1.18070.2.2.1.13.2.1
ospfIdxAn index used to identify the OSPF instance in order to alow for creation and deletion to allow compatibility with TL1 and CLI interfaces. Note the value is always 1.
INTEGER (1)
.1.3.6.1.4.1.18070.2.2.1.13.2.1.1
ospfRouterIdA 32-bit integer uniquely identifying the router. By convention, to ensure uniqueness, this should default to the value of one of the router's IP interface addresses. This object is persistent.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.13.2.1.2
ospfAdminStatThe administrative status of OSPF in the router. The value 'enabled' denotes that the OSPF Process is active on at least one interface; 'disabled' disables it on all interfaces. This object is persistent.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.13.2.1.3
ospfVersionNumberThe current version number of the OSPF protocol is 2.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.13.2.1.4
ospfAreaBdrRtrStatusA flag to note whether this router is an Area Border Router.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.13.2.1.5
ospfRouteRedistIndicates the extent of route redistribution. Static - static routes, Connected - routes connected to the node. DefOrig - default routes from adjacent nodes.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.13.2.1.6
ospfAreaIdThe area ID associated with this OSPF item. Note that although the area ID has the format of an IP Address it is not actually an IP address.rw
IpAddress
.1.3.6.1.4.1.18070.2.2.1.13.2.1.7
ospfRowStatusUsed to control the addition and deletion of the ospf General Group parameters.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.13.2.1.8
ospfIfTableThe OSPF Interface Table describes the interfaces from the viewpoint of OSPF.
SEQUENCE OF OspfIfEntry
.1.3.6.1.4.1.18070.2.2.1.13.3
ospfIfEntryThe OSPF interface entry describes one interface from the viewpoint of OSPF. Information in this table is persistent and when this object is written the entity is saved to non-volatile storage.
OspfIfEntry
.1.3.6.1.4.1.18070.2.2.1.13.3.1
ospfIfSwitchIdThe number of the switch id on which the OSPF interface exists. Set to zero if the switchId a switch Id is not applicable for identification of the OSPF interface.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.13.3.1.1
ospfIfShelfIdxThe number of the shelf on which the OSPF interface exists.ro
INTEGER (1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.13.3.1.2
ospfIfSlotIdxThe number of the slot within the shelf corresponding to the OSPF interface.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.13.3.1.3
ospfIfTypeThe type of the interface corresponding to the OSPF interface. Set to zero if the ospfIfType is not applicable for identification of the OSPF interface.ro
PvxPortType
.1.3.6.1.4.1.18070.2.2.1.13.3.1.4
ospfIfIdxThe number of the interface within the slot corresponding to the OSPF interface.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.13.3.1.5
ospfIfSubIdxThe number of the sub-interface that the OSFP Interface corresponds to. Set to zero if the ospfIfSubIdx is not applicable for identification of the OSPF interface.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.13.3.1.6
ospfIfAreaIdA 32-bit integer uniquely identifying the area to which the interface connects. Area ID 0.0.0.0 is used for the OSPF backbone.ro
AreaID
.1.3.6.1.4.1.18070.2.2.1.13.3.1.7
ospfIfAdminStatThe OSPF interface's administrative status. The value formed on the interface, and the interface will be advertised as an internal route to some area. The value 'disabled' denotes that the interface is external to OSPF.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.13.3.1.8
ospfIfRtrPriorityThe priority of this interface. Used in multi-access networks, this field is used in the designated router election algorithm. The value 0 signifies that the router is not eligible to become the designated router on this particular network. In the event of a tie in this value, routers will use their Router ID as a tie breaker.rw
INTEGER (0..'FF'h)
.1.3.6.1.4.1.18070.2.2.1.13.3.1.9
ospfIfTransitDelayThe estimated number of seconds it takes to transmit a link state update packet over this interface. Note that the minimal value SHOULD be 1 second.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.13.3.1.10
ospfIfRetransIntervalThe number of seconds between link state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database description and Link State request packets. Note that minimal value SHOULD be 1 second.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.13.3.1.11
ospfIfHelloIntervalThe length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for all routers attached to a common network.rw
INTEGER ( 1..'FFFF'h ) UNITS "seconds"
.1.3.6.1.4.1.18070.2.2.1.13.3.1.12
ospfIfRtrDeadIntervalThe number of seconds that a router's Hello packets have not been seen before its neighbors declare the router down. This should be some multiple of the Hello interval. This value must be the same for all routers attached to a common network.rw
INTEGER ( 0..'7FFFFFFF'h ) UNITS "seconds"
.1.3.6.1.4.1.18070.2.2.1.13.3.1.13
ospfIfMetricValueA metric used to identify the 'cost' associated with using this interface.rw
INTEGER (0..'FFFF'h)
.1.3.6.1.4.1.18070.2.2.1.13.3.1.14
ospfIfStatusThis object permits management of the table by facilitating actions such as row creation, construction, and destruction. The value of this object has no effect on whether other objects in this conceptual row can be modified.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.13.3.1.15
ospfLsdbTableThe OSPF Process's link state database (LSDB). The LSDB contains the link state advertisements from throughout the areas that the device is attached to.
SEQUENCE OF OspfLsdbEntry
.1.3.6.1.4.1.18070.2.2.1.13.4
ospfLsdbEntryA single link state advertisement.
OspfLsdbEntry
.1.3.6.1.4.1.18070.2.2.1.13.4.1
ospfLsdbAreaIdThe 32-bit identifier of the area from which the LSA was received.ro
AreaID
.1.3.6.1.4.1.18070.2.2.1.13.4.1.1
ospfLsdbTypeThe type of the link state advertisement. Each link state type has a separate advertisement formatro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.13.4.1.2
ospfLsdbLsidThe Link State ID is an LS Type Specific field containing either a Router ID or an IP address; it identifies the piece of the routing domain that is being described by the advertisement.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.13.4.1.3
ospfLsdbRouterIdThe 32-bit number that uniquely identifies the originating router in the Autonomous System.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.13.4.1.4
ospfLsdbSequenceThe sequence number field is a signed 32-bit integer. It starts with the value '80000001'h, or -'7FFFFFFF'h, and increments until '7FFFFFFF'h. Thus, a typical sequence number will be very negative. It is used to detect old and duplicate Link State Advertisements. The space of sequence numbers is linearly ordered. The larger the sequence number, the more recent the advertisement.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.13.4.1.5
ospfLsdbAgeThis field is the age of the link state advertisement in seconds.ro
Integer32 UNITS "seconds"
.1.3.6.1.4.1.18070.2.2.1.13.4.1.6
ospfLsdbChecksumThis field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum. The checksum used is the same that is used for ISO connectionless datagrams; it is commonly referred to as the Fletcher checksum.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.13.4.1.7
ospfNbrTableA table describing all non-virtual neighbors in the locality of the OSPF router.
SEQUENCE OF OspfNbrEntry
.1.3.6.1.4.1.18070.2.2.1.13.5
ospfNbrEntryThe information regarding a single neighbor. Information in this table is persistent and when this object is written the entity SHOULD save the change to non-volatile storage.
OspfNbrEntry
.1.3.6.1.4.1.18070.2.2.1.13.5.1
ospfNbrIpAddrThe IP address this neighbor is using in its IP source address. Note that, on addressless links, this will not be 0.0.0.0 but the address of another of the neighbor's interfaces.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.13.5.1.1
ospfNbrAddressLessIndexOn an interface having an IP address, zero. On addressless interfaces, the corresponding value of ifIndex in the Internet Standard MIB. On row creation, this can be derived from the instance.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.13.5.1.2
ospfNbrRtrIdA 32-bit integer (represented as a type IpAddress) uniquely identifying the neighboring router in the Autonomous System.ro
IpAddress
.1.3.6.1.4.1.18070.2.2.1.13.5.1.3
ospfNbrOptionsA bit mask corresponding to the neighbor's options field. Bit 0, if set, indicates that the system will operate on Type of Service metrics other than TOS 0. If zero, the neighbor will ignore all metrics except the TOS 0 metric. Bit 1, if set, indicates that the associated area accepts and operates on external information; if zero, it is a stub area. Bit 2, if set, indicates that the system is capable of routing IP multicast datagrams, that is that it implements the multicast extensions to OSPF. Bit 3, if set, indicates that the associated area is an NSSA. These areas are capable of carrying type-7 external advertisements, which are translated into type-5 external advertisements at NSSA borders.ro
Integer32
.1.3.6.1.4.1.18070.2.2.1.13.5.1.4
ospfNbrPriorityThe priority of this neighbor in the designated router election algorithm. The value 0 signifies that the neighbor is not eligible to become the designated router on this particular network.ro
DesignatedRouterPriority
.1.3.6.1.4.1.18070.2.2.1.13.5.1.5
ospfNbrStateThe state of the relationship with this neighbor.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.13.5.1.6
pvxObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.14
pvxBridge
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.14.1
pvxL2IntfTableThis table contains one row for every provisioned Ethernet facility on the system. Each row contains a list of attributes that pertain to the facility.
SEQUENCE OF PVXL2IntfEntry
.1.3.6.1.4.1.18070.2.2.1.14.1.3
pvxL2IntfEntryThe conceptual row object of the ethIntfTable table.
PVXL2IntfEntry
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1
pvxL2IntfSwitchIdxThe number of the switch id of the provisioned ethernet facility.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.1
pvxL2IntfShelfIdxThe number of the shelf id of the provisioned ethernet facility.ro
INTEGER (0|1|11|21|31)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.2
pvxL2IntfSlotIdxThe number of the instance id of the provisioned ethernet facility.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.3
pvxL2IntfPortTypeIdxThe number of the instance id of the provisioned ethernet facility.ro
PvxPortType
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.4
pvxL2IntfPortIdxThe number of the port on the circuit pack on which the ethernet facility is provisioned.ro
INTEGER
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.5
pvxL2IntfAdminStatusThe administrative status of the Ethernet facility.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.6
pvxL2IntfOperStatusThe reported operational status of the Ethernet facility.ro
OperStatus
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.7
pvxL2IntfTypeThis object is used to configure the type of a interface.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.8
pvxL2IntfSTpidThe Ethernet type (TPID) of the S-TAGrw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.9
pvxL2IntfPvidThe PVID (port-based VLAN ID) for the portrw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.10
pvxL2IntfDefaultPriorityThis object sets the default priority of the interface.rw
INTEGER
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.11
pvxL2IntfAllowedFramesTODO: Does this feild need to support OR of the options?rw
Enumeration
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.12
pvxL2IntfIngressFilteringWhen this is true(1) the device will discard incoming frames for VLANs which do not include this Port in its Member set. When false(2), the port will accept all incoming frames. This control does not affect VLAN independent BPDU frames, such as GVRP and STP. It does affect VLAN dependent BPDU frames, such as GMRP.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.13
pvxL2IntfCtrlFrmProfileIdrwdeprecated
Integer32
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.14
pvxL2IntfMACAddrThe MAC address of the interface.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.15
pvxL2IntfRateLimitThis represents the interface rate limit in kilobits/s.rw
Integer32
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.16
pvxL2IntfCoSProfileIdThis represents the Class of service profile for the interface.rw
Integer32
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.17
pvxL2IntfIsUNIThe Switch port type. The default value set by the switch is neither.ro
Enumeration
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.18
pvxL2IntfSchedProfNameThe scheduler profile used by the interface.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.19
pvxL2IntfPriTCMapProfNameThe priority to traffic class map profile used by the interface.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.20
pvxL2IntfPCPCodingProfNameThe scheduler profile used by the interface.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.21
pvxL2IntfDscpPHBProfNameThe internal priority setting for DSCP profile used by the interface.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.22
pvxL2IntfCtrlFrmProfileNameThe L2 control frame profile used by the interface.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.23
pvxL2IntfUseDeiUsed by PNP port. By default, it is set to false by the switch.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.24
pvxL2IntfIngressBandwidthProfileThe ingress policy map profile used by the interface.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.25
pvxL2IntfEgressBandwidthProfileThe egress policy map profile used by the interface.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.26
pvxL2IntfTrustIncomingPCPUsed by all port type. By default, it is set to true by the switch.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.27
pvxL2IntfTrustIncomingDscpUsed by all port type. By default, it is set to true by the switch.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.28
pvxL2IntfBcastLimitBroadcast rate limit as percentage of the line rate for the port with default value of 100 (no storm control).rw
INTEGER (20|40|60|100)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.29
pvxL2IntfMcastLimitMulticast rate limit as percentage of the line rate for the port with default value of 100 (no storm control).rw
INTEGER (20|40|60|100)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.30
pvxL2IntfDlfLimitUnicast DLF rate limit as percentage of the line rate for the port with default value of 100 (no storm control).rw
INTEGER (20|40|60|100)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.31
pvxL2IntfRowStatusUsed to control the addition and deletion of entries in the PVX L2 Interface table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.14.1.3.1.100
pvxNotificationObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.14.4
mstpNotificationObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.14.4.1
miscellaneous
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.15
setErrorInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.15.1
setErrorCodeThe BTI-specific error code for the set request failure.rw
Integer32
.1.3.6.1.4.1.18070.2.2.1.15.1.1
setErrorDescA textual description string that explains the reason for the failed set request.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.1.15.1.2
opticalLayer
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.1.16
notifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2
eventNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1
evtNotificationObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.1
evtDateAndTimeThe date and time at which an event notification was issued by the system.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.2.1.1.1
tcaIntervalTypeThe type of PM bin according to interval length during which a performance monitoring threshold crossing occurred.ro
PMIntervalType
.1.3.6.1.4.1.18070.2.2.2.1.1.2
tcaDateAndTimeThe date and time of the performance monitoring interval for which a performance monitoring threshold crossing alert is generated.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.2.1.1.3
tcaMontypeIdentify the performance monitoring monitored type for which a threshold crossing alert is generated.ro
PMMontype
.1.3.6.1.4.1.18070.2.2.2.1.1.4
tcaValueThe measured value of the monitored type for which a performance monitoring threshold crossing alert is generated.ro
Unsigned32
.1.3.6.1.4.1.18070.2.2.2.1.1.5
tcaThresholdThe threshold for the monitored type that was exceeded resulting in the generation of a performance monnitoring threshold crossing alert.ro
Unsigned32
.1.3.6.1.4.1.18070.2.2.2.1.1.6
evtDescriptionA textual decription of the event.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.2.1.1.7
evtObjectTypeIdentifies the type of managed object against which the event notification is raised.ro
NotifObjectType
.1.3.6.1.4.1.18070.2.2.2.1.1.8
evtCodeTypeThis object value uniquely identifies the type of event that has been generated.ro
NotifCodeType
.1.3.6.1.4.1.18070.2.2.2.1.1.9
neEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.2
shelfInvEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.3
shelfInvPluginEvtA shelf has been detected through the shelf interconnect.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.3.0.1
shelfInvUnpluginEvtA previously detected shelf is no longer detected through the shelf interconnect.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.3.0.2
slotInvEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.4
slotInvPluginEvtA circuit pack has been inserted into the identified slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.4.0.1
slotInvUnpluginEvtA circuit pack has been removed from the identified slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.4.0.2
slotInvUpgradeStageResultEvtThe software upgrade process on the circuit pack in the identified slot has completed a stage.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.4.0.3
shelfEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.5
shelfStatusChangeEvtNotification of a change in the shelf's operational status or operational status qualifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.5.0.1
cpEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.6
cpStatusChangeEvtNotification of a change in the circuit pack's operational status or operational status qualifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.1
cpCheckUpgradeResultEvtIndicates the result of the check upgrade step of the system-wide software upgrade process.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.2
cpUpgradeTransferResultEvtIndicates the result of the software download step of the system-wide software upgrade process.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.3
cpUpgradeStageResultEvtThe software upgrade process on the active circuit pack in the identified slot has completed a stage.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.4
cpDbBackupResultEvtIndicates the result of an NE database backup operation.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.5
cpDbRestoreTransferResultEvtIndicates the result of the database download step of the NE database restore process.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.6
cpDbInvokeResultEvtIndicates the result of the invoke step of the NE database restore process.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.7
cpDbApplyResultEvtIndicates the result of the accept step of the NE database restore process.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.6.0.8
oaEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.7
oaStatusChangeEvtNotification of a change in the optical amplifier's operational status or operational status qualifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.7.0.1
dataCommsEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.8
oscStatusChangeEvtNotification of a change in the optical supervisory channels's operational status or operational status qualifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.8.0.1
netMgmtStatusChangeEvtNotification of a change in the network management interface's operational status or operational status qualifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.8.0.2
pluggableInvEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.9
pluggableInvPluginEvtA pluggable transceiver has been inserted into the identified port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.9.0.1
pluggableInvUnpluginEvtA pluggable transceiver has been removed from the identified port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.9.0.2
xcvrEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.10
xcvrStatusChangeEvtNotification of a change in the transceiver's operational status or operational status qualifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.10.0.1
xcvrProtSwitchEvtA protection switch has occured on the optical transceiver facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.10.0.2
xcvrTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on an optical transceiver port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.10.0.3
adminEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.11
amdEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.12
amdStatusChangeEvtNotification of a change in the operational status or operational status qualifier of an active multiplexer-demultiplexer port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.12.0.1
ocnEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.13
ocnStatusChangeEvtNotification of a change in the operational status or operational status qualifier of a SONET OC-N facility port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.13.0.1
ocnTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on a SONET OC-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.13.0.2
ocnProtSwitchEvtA protection switch has occured on the identified OC-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.13.0.3
stsnEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.14
stsnProtSwitchEvtA protection switch has occured on the identified STS-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.14.0.2
stsnTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on a SONET STS-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.14.0.3
stmnEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.15
stmnStatusChangeEvtNotification of a change in the operational status or operational status qualifier of a SDH STM-N facility port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.15.0.1
stmnTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on a SDH STM-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.15.0.2
stmnProtSwitchEvtA protection switch has occured on the identified STM-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.15.0.3
vcnEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.16
vcnProtSwitchEvtA protection switch has occured on the identified VC-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.16.0.2
vcnTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on a SDH VC-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.16.0.3
geEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.17
geStatusChangeEvtNotification of a change in the operational status or operational status qualifier of a Gigabit Ethernet facility port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.17.0.1
geTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on a Gigabit Ethernet facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.17.0.2
fcEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.18
fcStatusChangeEvtNotification of a change in the operational status or operational status qualifier of a Fiber Channel facility port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.18.0.1
fcTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on a Fiber Channel facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.18.0.2
ethPortEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.21
ethL1IFStatusChangeEvtNotification of a change in the operational status or operational status qualifier of a L1 Ethernet facility port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.21.0.1
ethL1IFTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on an Ethernet Layer 1 interface facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.21.0.2
pvxL2EvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.22
pvxL2IFTcaEvtThis trap provides a threshold crossing alert for a performance monitoring statistic on a PVX Pack Ethernet Layer 2 interface facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.22.0.2
mstpEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.23
briEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.24
briStatusChangeEvtNotification of a change in the operational status or operational status qualifier of a BRI facility port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.24.0.1
cpSynchronizationEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.25
cpSynchronizationSwitchEvtA synchronization timing reference switch has occurred on the identified circuit pack.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.25.0.1
pvxESrvcBWPrflEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.26
pvxESrvcEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.27
pvxERPSSrvcNNIEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.28
pvxERPSSrvcEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.29
pvxSlaMsmtEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.30
ntpcEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.31
ntpTimeAndDateUpdateEvtThis event occurs when the NTP client updates the system date and time based on a selected reference clocks source.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.31.0.1
ntpTimingRefUpdateEvtThis event occurs when the NTP client has selected a reference clock source from a list provided. This is the NTP association list.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.31.0.2
pvxSUniEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.32
olEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.33
pvxLldpEvtNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.1.34
pvxLldpRemTablesChangeEvtA pvxLldpRemTablesChangeEvt notification is sent when the value of pvxLldpStatsRemTablesLastChangeTime changes. It can be utilized by an NMS to trigger LLDP remote systems table maintenance polls. Note that transmission of lldpRemTablesChange notifications are throttled by the agent. The agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. By default the throttling period is set to 10 seconds.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.1.34.0.1
conditionNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2
neCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.1
shelfInvCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.2
shelfInvMissingCondAn expansion shelf is missing. To clear this condition, attach an appropriate expansion shelf to the MSCP in the main shelf of the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.1
shelfInvMissingClearA previously active shelf missing condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.2
shelfInvUnknownCondA shelf is unknown to the system. This condition occurs because the shelf is unknown to the system (for example, the the FRU data cannot be read on the expansion shelf interface (ESI) circuit pack in the expansion shelf). To clear this condition, connect an appropriate shelf to its associated MSCP.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.3
shelfInvUnknownClearA previously active shelf unknown condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.4
shelfInvCommCondThis condition indicates that a connected expansion shelf has a communications failure between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.5
shelfInvCommClearA previously active shelf communications condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.6
shelfInvPwrFeedAFailCondThere is a power feed A failure. The system can continue to function on power feed B. Plan to diagnose and correct the problem as soon as possible.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.7
shelfInvPwrFeedAFailClearA previously active Power feed A condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.8
shelfInvPwrFeedBFailCondThere is a power feed B failure. The system can continue to function on power feed A. Plan to diagnose and correct the problem as soon as possible.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.9
shelfInvPwrFeedBFailClearA previously active Power feed B condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.10
shelfInvPwrBrownoutCondThere is a system power brownout. As voltage levels decrease, the amplifiers fail, followed by the MSCP, and then the cooling unit fails.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.11
shelfInvPwrBrownoutClearA previously active power brownout condition on the shelf has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.12
shelfInvSysCommCondThis condition indicates that backplane communication between the multiport system control processor (MSCP) and the affected circuit pack is interrupted. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, are affected while this alarm is active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.13
shelfInvSysCommClearA previously active shelf missing condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.14
shelfInvExpansionShelfIdMismatchCondIndicates that the identifying information of the discovered expansion shelf does not match that of the expected shelf.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.15
shelfInvExpansionShelfIdMismatchClearA previously active expansion shelf identifier mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.16
shelfInvExpansionShelfCommLOSCondThis alarm indicates that a connected expansion shelf has a loss of signal between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs. The most likely causes are a fiber cut or a fault with the Molex connector and cable assembly.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.17
shelfInvExpansionShelfCommLOSClearA previously active expansion shelf communications LOS condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.18
shelfInvExpansionShelfCommLinkDownCondThis alarm indicates that a connected expansion shelf has a communications failure between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.19
shelfInvExpansionShelfCommLinkDownClearA previously active expansion shelf communications link down condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.20
shelfInvExpansionShelfCommDeviceUnsupportedCondThis alarm indicates that an unknown device is connected to the expansion shelf port of the multiport system control processor (MSCP) on the main shelf.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.21
shelfInvExpansionShelfCommDeviceUnsupportedClearA previously active expansion shelf communications device unsupported condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.22
shelfInvTempMaxCondIndicates that the temperature on the identified shelf has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.23
shelfInvTempMaxClearA previously active shelf inventory maximum temperature condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.2.0.24
slotInvCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.3
slotInvMissingCondA Circuit pack is missing. The alarm is triggered for one of the following reasons: the provisioned circuit pack is missing from its associated slot a filler circuit pack is missing from an unprovisioned single-width or doublewidth slot a single-width circuit pack is provisioned in a double-width slot To clear this alarm, insert an appropriate single-width or double-width circuit pack or filler circuit pack in the associated single-width or double-width slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.1
slotInvMissingClearA previously active circuit pack or replaceable unit missing condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.2
slotInvUnknownCondCircuit pack type is unknown to the system. This condition occurs for the following two reasons: the circuit pack in the associated slot is unknown to the system (for example, the circuit pack is not supported by the software release running on the system) two single-width circuit packs are in a double-width slot To clear this condition, insert an appropriate circuit pack in the associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.3
slotInvUnknownClearA previously active circuit pack or replaceable unit unknown condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.4
slotInvCommCondThis alarm indicates that backplane communication between the multiport system control processor (MSCP) and the circuit pack is interrupted. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, are affected while this alarm is active. If an amplifier or wavelength conversion circuit pack has been provisioned already, it continues to operate normally.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.5
slotInvCommClearA previously active circuit pack communications condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.6
slotInvFailCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.7
slotInvFailClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.8
slotInvUpgradeInProgressCondA software upgrade process has begun on the circuit pack in the identified slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.9
slotInvUpgradeInProgressClearThere is an auto upgrade in progress. This alarm is typically seen when inserting a circuit pack other than a multiport system control processor (MSCP).
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.10
slotInvUpgradeFailureCondThere is a circuit pack upgrade failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.11
slotInvUpgradeFailureClearA previously active circuit pack software upgrade failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.12
slotInvVersionMismatchCondThe circuit pack in the indicated slot is running a software version which is inconsistent with the committed software version of the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.13
slotInvVersionMismatchClearA previously active circuit pack software version mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.14
slotInvCoolingUnitFailCondA cooling unit failure has occurred. One or more fans have failed in the cooling unit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.15
slotInvCoolingUnitFailClearA previously active shelf cooling unit failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.16
slotInvDspCommCondThis alarm indicates that communication has failed either between the DSP and the processor handling backplane communications on an optical amplifier circuit pack, or between the variable optical equalizer (VOE) and the processor handling backplane communications on an active mux/demux circuit pack Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, is affected when this alarm is active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.17
slotInvDspCommClearA previously active DSP control communications condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.18
slotInvUnsupportedPackCondA replaceable unit inventory item is unsupported. In this case, a multiport system control processor (MSCP) circuit pack is plugged into any slot of the expansion shelf. However, MSCPs are only supported in slot five of the main shelf.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.19
slotInvUnsupportedPackClearA previously active unsupported pack condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.20
slotInvCoolingUnitMismatchCondThe shelf is plugged in with a wring cooling unit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.21
slotInvCoolingUnitMismatchClearA previously active cooling unit mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.22
slotInvPwrFeedAFuseFailCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.23
slotInvPwrFeedAFuseFailClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.24
slotInvPwrFeedBFuseFailCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.25
slotInvPwrFeedBFuseFailClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.26
slotInvPowerFailCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.27
slotInvPowerFailClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.28
slotInvHiTempAutoShutdownCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.29
slotInvHiTempAutoShutdownClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.30
slotInvHTThreshExceededCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.31
slotInvHTThreshExceededClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.32
slotInvHTSThreshExceededCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.33
slotInvHTSThreshExceededClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.34
slotInvHTASUnsupportedCondThere is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.35
slotInvHTASUnsupportedClearA previously active circuit pack fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.3.0.36
shelfCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.4
shelfMismatchCondThe type of the physically detected shelf does not match the provisioned shelf type.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.4.0.1
shelfMismatchClearA previously active shelf type mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.4.0.2
shelfMissingCondAn expansion shelf is missing. To clear this alarm, attach an appropriate expansion shelf to the MSCP in the main shelf of the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.4.0.3
shelfMissingClearA previously active expansion shelf missing condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.4.0.4
shelfConfigurationMismatchCondThe configuration type of the physically detected expansion shelf does not match the provisioned expansion shelf configuration type.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.4.0.5
shelfConfigurationMismatchClearA previously active expansion shelf configuration mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.4.0.6
cpCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.5
cpMismatchCondThere is a circuit pack mismatch. There is a mismatch between the equipment provisioned for the slot and the physical circuit pack that is inserted in the slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.1
cpMismatchClearA previously active circuit pack type mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.2
cpConnectorMismatchCondA connector mismatch alarm occurs on a circuit pack that is provisioned with a connector type that is different to the one actually inserted.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.3
cpConnectorMismatchClearA previously active optical fiber connector type mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.4
cpInvalidProvCondThe type of circuit pack that is provisioned in a slot that is invalid for the shelf slot configuration.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.5
cpInvalidProvClearA previously active invalid circuit pack provisioning condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.6
cpSoftwareBankAFailCondThere is a hardware failure in software bank A storage device. During this alarm, software backups, upgrades and restores cannot occur. When the MSCP is rebooting, the LEDs on the MSI and the MSCP are lit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.7
cpSoftwareBankAFailClearA previously active software Bank A failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.8
cpSoftwareBankBFailCondThere is a hardware failure in software bank B storage device. During this alarm, software backups, upgrades, and restores cannot occur. When the MSCP is rebooting, the LEDs on the MSI and the MSCP are lit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.9
cpSoftwareBankBFailClearA previously active software Bank B failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.10
cpUpgradeInProgressCondIndicates that a system-wide software upgrade process is in progress on the NE.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.11
cpUpgradeInProgressClearA previously active system-wide upgrade in progress condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.12
cpUpgradeFailCondIndicates that the system-wide upgrade procedure has failed to complete successfully.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.15
cpUpgradeFailClearA previously active circuit pack upgrade failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.16
cpDbRestoreInProgressCondThere is a database restore in progress on the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.17
cpDbRestoreInProgressClearA previously active NE database restore condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.18
cpDbRecoveryFailCondThere is a database recovery failure. If a new MSCP circuit pack fails to acquire the database from the system, a database recovery failure alarm can be triggered after replacing the MSCP.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.19
cpDbRecoveryFailClearA previously active NE database recovery failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.20
cpFanFeedFailCondA cooling unit feed failure has occurred on a BTI 7030 shelf. There are two cooling unit power feeds from the SCP to the cooling unit. If one power feeds fails, a minor alarm is raised. If both power feed fails, a major alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.21
cpFanFeedFailClearA previously active fan power feed failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.22
cpStorageCardFailCondIndicates that the database storage card has failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.23
cpStorageCardFailClearA previously active database storage card failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.24
cpDbDeletionInProgressCondThere is a database deletion in progress on the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.25
cpDbDeletionInProgressClearA previously active NE database deletion condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.26
cpDegradeCondIndicates that a failure or degradation has been detected in one or more physical components on the identified circuit pack, which may lead to a failure of the pack to provide service normally.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.27
cpDegradeClearA previously active Circuit Pack Degrade condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.5.0.28
oaCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.6
oaCaseTempCondA case temperature high threshold is exceeded. A warning is raised to indicate that the amplifier is nearing its shutdown threshold. The circuit pack in the associated slot has exceeded its case temperature high threshold. If the case temperature continues to rise to its shutdown threshold, the circuit pack automatically shuts down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.1
oaCaseTempClearA previously active optical amplifier case temperature condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.2
oaCaseTempShutdownCondA case temperature high threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system. The pump lasers are turned off and there is no amplification.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.3
oaCaseTempShutdownClearA previously active optical amplifier case temperature shutdown condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.4
oaLaserMinTempShutdownCondA pump laser temperature low threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.5
oaLaserMinTempShutdownClearA previously active optical amplifier minimum temperature shutdown condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.6
oaLaserMaxTempShutdownCondA pump laser temperature high threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.7
oaLaserMaxTempShutdownClearA previously active optical amplifier maximum temperature shutdown condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.8
oaOpticalPwrReceivedMinCondThe optical power received (OPR) low threshold is exceeded. The input signal to an optical amplifier has reached the optical power received low threshold. If the input signal drops to below the input sensitivity level, the circuit pack will degrade in performance.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.9
oaOpticalPwrReceivedMinClearA previously active optical amplifier minimum power received condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.10
oaOpticalPwrReceivedMaxCondThe optical power received (OPR) high threshold is crossed. The input signal to an optical amplifier has reached the optical power received high threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.11
oaOpticalPwrReceivedMaxClearA previously active optical amplifier maximum power received condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.12
oaSSIOpticalPwrReceivedMaxCondA second stage input optical power received (OPR) high threshold crossing has occurred.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.13
oaSSIOpticalPwrReceivedMaxClearA previously active optical amplifier second stage input maximum power received condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.14
oaBackReflectionSafetyCondThe Optical Back Reflection - High Threshold Safety Override alarm indicates someone has activated the optical power received optical back reflection high threshold safety override (OPR-OBR-HTSO) command to override the automatic power reduction (APR) feature of the amplifier lasers. This command overrides the APR feature of the amplifier for 20 to 600 seconds. When the timer expires, the alarm clears.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.17
oaBackReflectionSafetyClearA previously active optical amplifier back reflection safety condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.18
oaOpticalPwrTransmittedMinCondThe optical power transmitted (OPT) low threshold is crossed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.19
oaOpticalPwrTransmittedMinClearA previously active optical amplifier minimum transmitted power condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.20
oaOpticalPwrTransmittedMaxCondThe optical power transmitted (OPT) high threshold has been exceeded on the amplifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.21
oaOpticalPwrTransmittedMaxClearA previously active optical amplifier maximum transmitted power condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.22
oaMSInsertionLossCondA mid-stage insertion loss high threshold is exceeded for a mid-stage amplifier.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.23
oaMSInsertionLossClearA previously active optical amplifier midstage insertion loss condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.24
oaAmplifierConditioningCondThere is an amplifier conditioning problem. When an amplifier is initially plugged in, thermo-electric coolers (TEC) work to control the pump laser temperature to between 16 degrees and 34 degrees Celsius. Until the pump laser temperature is within range, the amplifier conditioning problem is present. If the amplifier conditioning problem persists for more than 30 minutes, the condition is cleared and either a laser temperature low threshold or a laser temperature high threshold alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.25
oaAmplifierConditioningClearA previously active optical amplifier conditioning condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.26
oaDspCommCondThis alarm indicates that communication has failed between the DSP and the processor handling backplane communications on an optical amplifier circuit pack. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, is affected when this alarm is active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.27
oaDspCommClearA previously active optical amplifier DSP communications condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.28
oaBackReflectionSafetyOverrideCondThe Optical Back Reflection - High Threshold Safety Override alarm indicates someone has activated the high threshold safety override command to override the automatic power reduction (APR) feature of the amplifier lasers. This command overrides the APR feature of the amplifier for 20 to 600 seconds. When the timer expires, the alarm clears.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.41
oaBackReflectionSafetyOverrideClearA previously active back reflection safety override condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.42
oaBackReflectionHighThresholdCondThe Optical Amplifier Back Reflection High Threshold alarm indicates that the measured optical back reflection power has exceeded the high threshold. This serves as a warning that optical back reflection is operating at an elevated level, and that continued increases in the optical back reflection level may result in an automatic laser safety shutdown.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.43
oaBackReflectionHighThresholdClearA previously active back reflection high threshold condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.6.0.44
dataCommsCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.7
oscLossOfSignalCondThis condition indicates that an SFP transceiver has experienced an input power drop that is below the manufacturer s preset threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.7.0.1
oscLossOfSignalClearA previously active optical supervisory channel loss of signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.7.0.2
oscSfpMissingCondAn SFP transceiver is missing from its associated port in an MSCP circuit pack. To clear this alarm, insert an appropriate transceiver in the associated port of the MSCP circuit pack.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.7.0.3
oscSfpMissingClearA previously active optical supervisory channel SFP missing condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.7.0.4
pluggableInvCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.8
pluggableInvUnknownCondThe SFP or XFP transceiver type is unknown to the system. This alarm occurs because the transceiver is not supported by the current software. To clear this alarm, insert a readable SFP or XFP transceiver in the associated port of the circuit pack.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.1
pluggableInvUnknownClearA previously active Pluggable Inventory Unknown condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.2
pluggableInvCommCondThis alarm indicates that communication between a circuit pack and an inserted small form factor pluggable (SFP) transceiver is not reliable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.3
pluggableInvCommClearA previously active Pluggable Inventory communications condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.4
pluggableInvFailCondThere is an SFP or XFP transceiver failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.5
pluggableInvFailClearA previously active Pluggable Inventory fail condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.6
pluggableInvMismatchCondThere is an SFP mismatch condition active. There is a mismatch between the SFP transceiver provisioned for a port of a circuit pack and the physical SFP transceiver that is inserted in the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.7
pluggableInvMismatchClearA previously active Pluggable Inventory mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.8
pluggableInvMissingCondThere is an SFP or XFP missing from the indicated port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.9
pluggableInvMissingClearA previously active Pluggable Inventory missing condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.10
pluggableInvUnsupportedCondThe electrical SFP transceiver type is NOT supported in the given port. This alarm occurs when an electrical SFP is plugged into a port that does not support GE. To clear this alarm, remove the electrical SFP.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.11
pluggableInvUnsupportedClearA previously active Pluggable unsupported condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.8.0.12
xcvrCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.9
xcvrMissingCondAn SFP or XFP transceiver is missing from its associated port in a circuit pack.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.1
xcvrMissingClearA previously active transceiver port missing condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.2
xcvrMismatchCondThere is a mismatch between the SFP or XFP transceiver provisioned for a port of a circuit pack and the physical SFP or XFP transceiver that is inserted in the port. The provisioned SFP or XFP transceiver must match the transceiver in the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.3
xcvrMismatchClearA previously active transceiver port type mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.4
xcvrRFICondRemote Fault Indication: The source port to which the specified destination transceiver port is cross-connected has a service-affecting fault active against it.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.5
xcvrRFIClearA previously active transceiver RFI condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.6
xcvrLossOfSignalCondThis alarm indicates that an SFP transceiver has experienced an input power drop that is below the preset minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.7
xcvrLossOfSignalClearA previously active transceiver port Loss Of Signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.8
xcvrLossOfLockCondThis alarm indicates that a transceiver port is unable to lock on the incoming bit stream. This is a result of either: the provisioned protocol does not match the incoming signal, or the incoming signal is excessively degraded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.9
xcvrLossOfLockClearA previously active transceiver port Loss Of Lock condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.10
xcvrOpticalPwrReceivedMinCondThe optical power received (OPR) low threshold is not met. The input signal to a transceiver has reached the optical power received low threshold. If the input signal drops to below the input sensitivity level, the transceiver degrades in performance.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.11
xcvrOpticalPwrReceivedMinClearA previously active transceiver port minimum power received condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.12
xcvrOpticalPwrReceivedMaxCondThe optical power received (OPR) high threshold is exceeded. The input signal to a transceiver has reached the optical power received high threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.13
xcvrOpticalPwrReceivedMaxClearA previously active transceiver port maximum power received condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.14
xcvrOpticalPwrTransmittedMinCondThe optical power transmitted (OPT) is below the low threshold for the transceiver.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.15
xcvrOpticalPwrTransmittedMinClearA previously active transceiver port minimum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.16
xcvrOpticalPwrTransmittedMaxCondThe optical power transmitted (OPT) high threshold for a transceiver is exceeded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.17
xcvrOpticalPwrTransmittedMaxClearA previously active transceiver port maximum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.18
xcvrLossOfFrameCondA transceiver reports a SONET or SDH loss of frame for a transceiver that is provisioned to receive a SONET or SDH protocol.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.19
xcvrLossOfFrameClearA previously active loss of frame condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.20
xcvrLossOfSyncCondIndicates that a loss of synchronization condition has been detected by the transceiver port on the incoming gigabit ethernet or 10GELAN protocol.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.21
xcvrLossOfSyncClearA previously active loss of synchronization condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.22
xcvrLoopbackCondIndicates that the transceiver has been provisioned to enter loopback mode.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.27
xcvrLoopbackClearA previously active loopback condition on the transceiver has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.28
xcvrForcedSwitchToProtectionCondThe active transceiver of a protected transceiver pair has been forced to switch to the Protection transceiver.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.29
xcvrForcedSwitchToProtectionClearA previously active Forced Switch To Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.30
xcvrForcedSwitchToWorkingCondThe active transceiver of a protected transceiver pair has been forced to switch to the Working transceiver.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.31
xcvrForcedSwitchToWorkingClearA previously active Forced Switch To Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.32
xcvrLockoutProtectionCondThe Protection transceiver of a protected transceiver pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.33
xcvrLockoutProtectionClearA previously active Lockout Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.34
xcvrLockoutWorkingCondThe Working transceiver of a protected transceiver pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.35
xcvrLockoutWorkingClearA previously active Lockout Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.36
xcvrTempMaxCondIndicates that the temperature of the physical transceiver has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.37
xcvrTempMaxClearA previously active Temperature Exceeded Maximum condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.38
xcvrWavelengthNotAchievableCondIndicates that the transceiver is not currently able to tune to the set wavelength.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.39
xcvrWavelengthNotAchievableClearA previously active Wavelength Not Achievable condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.40
xcvrAlarmIndicationSignalCondAn Alarm Indication Signal indication is active on the transceiver port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.41
xcvrAlarmIndicationSignalClearA previously active Alarm Indication Signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.42
xcvrTraceMismatchCondThis condition indicates that the received trace label on the transciever port does not match the expected trace label.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.43
xcvrTraceMismatchClearA previously active Trace Mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.44
xcvrRemoteFaultCondA remote fault indication is active on the traceiver port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.45
xcvrRemoteFaultClearA previously raised remote fault indication has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.46
xcvrSignalDegradeCondThe Signal Degrade BER threshold has been crossed on the transiever port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.47
xcvrSignalDegradeClearA previously active Signal Degrade condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.48
xcvrOTNPayloadMismatchCondAn OTN payload mismatch is active on the transceiver port facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.49
xcvrOTNPayloadMismatchClearA previously active OTN payload mismatch condition on the transceiver port facility has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.50
xcvrLFCondLocal Failure: Raised when a port detects and incoming local failure indication is received.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.51
xcvrLFClearA previously active transceiver LF condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.52
xcvrOpenConnectionIndicatorCondAn Open Connection Indicator is active on the transceiver port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.53
xcvrOpenConnectionIndicatorClearA previously active Open Connection Indicator condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.54
xcvrReceivedLockoutCondA Received Lockout indication is active on the transceiver port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.55
xcvrReceivedLockoutClearA previously active Received Lockout condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.56
xcvrBackwardDefectIndicatorCondA Backward Defect Indicator is active on the transceiver port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.57
xcvrBackwardDefectIndicatorClearA previously active Backward Defect Indicator condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.9.0.58
adminCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.10
tl1UserLockoutCondA user is locked out of the system. After three incorrect attempts to login, a user is blocked from attempting to login again for 60 seconds.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.10.0.1
tl1UserLockoutClearA previously active TL1 User Lockout condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.10.0.2
tl1IpLockoutCondAfter three incorrect attempts to login from the same IP address, the IP address from which the three attempts are made is blocked for 60 seconds. When this condition is present in the actCondTable, the actCondTableEntryIdx will be set to the networkElement OID and the actCondInstanceIdx will be set to 0.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.10.0.3
tl1IpLockoutClearA previously active TL1 IP lockout condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.10.0.4
amdCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.11
amdLossOfSignalCondThis condition indicates that an active mux/demux that has experienced an input power drop that is below the preset threshold. This can be against either a channel or the composite line port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.1
amdLossOfSignalClearA previously raised active multiplexer-demultiplexer loss of signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.2
amdOpticalPwrReceivedMinCondIndicates that the input power for the active multiplexer-demultiplexer facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.3
amdOpticalPwrReceivedMinClearA previously raised active multiplexer-demultiplexer minimum power received condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.4
amdOpticalPwrReceivedMaxCondIndicates that the input power for the active multiplexer-demultiplexer facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.5
amdOpticalPwrReceivedMaxClearA previously raised active multiplexer-demultiplexer maximum power received condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.6
amdTPLNACondA channel target power level not achieved (TPLNA) condition is triggered when the output power for a channel of a 32-Channel DWDM Active Mux/Demux (D32AMD) module is above or below the target power transmitted level for that channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.7
amdTPLNAClearA previously raised active target power level not achieved condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.8
amdTALNACondThe target attenuation level not achieved (TALNA) condition is triggered when the attenuation for a 32-Channel DWDM Active Mux/Demux (D32AMD) is outside the preset attenuation levels for a composite line.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.9
amdTALNAClearA previously raised active target attenuation level not achieved condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.11.0.10
ocnCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.12
ocnLossOfSignalCondThis notification indicates that there is no input signal detected on the OC-N port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.1
ocnLossOfSignalClearThis notification indicates that a previously active OC-N Loss of Signal condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.2
ocnXcvrMismatchCondThere is a mismatch between the SFP or XFP transceiver provisioned for the OC-N facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the OC-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.3
ocnXcvrMismatchClearA previously active OC-N Mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.4
ocnOpticalPwrReceivedMinCondIndicates that the input power for the OC-N facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.5
ocnOpticalPwrReceivedMinClearA previously active OC-N minimum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.6
ocnOpticalPwrReceivedMaxCondIndicates that the input power for the OC-N facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.7
ocnOpticalPwrReceivedMaxClearA previously active OC-N maximum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.8
ocnOpticalPwrTransmittedMinCondIndicates that the output power for the OC-N facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.9
ocnOpticalPwrTransmittedMinClearA previously active OC-N minimum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.10
ocnOpticalPwrTransmittedMaxCondIndicates that the output power for the OC-N facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.11
ocnOpticalPwrTransmittedMaxClearA previously active OC-N maximum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.12
ocnLossOfFrameCondAn OC-N Loss of Frame condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.13
ocnLossOfFrameClearA previously active OC-N Loss of Frame condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.14
ocnSignalDegradeCondA signal degrade condition on the OC-N facility is active. This indicates that the detected bit error rate exceeds the degrade threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.15
ocnSignalDegradeClearA previously active OC-N Signal Degrade condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.16
ocnAlarmIndicationSignalCondAn OC-N Line-level Alarm Indication Signal indication is active on facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.17
ocnAlarmIndicationSignalClearA previously active OC-N Alarm Indication Signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.18
ocnLoopbackCondIndicates that the OC-N facility has been provisioned to enter loopback mode.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.19
ocnLoopbackClearA previously active loopback condition on the OC-N facility has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.20
ocnLossOfPrimaryTimingReferenceCondIndicates that the primary timing reference signal for the identified OC-N facility is missing or faulty and cannot be locked on.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.21
ocnLossOfPrimaryTimingReferenceClearA previously active OC-N Loss of Primary Timing Reference condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.22
ocnLossOfSecondaryTimingReferenceCondIndicates that the secondary timing reference signal for the identified OC-N facility is missing or faulty and cannot be locked on.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.23
ocnLossOfSecondaryTimingReferenceClearA previously active OC-N Loss of Secondary Timing Reference condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.24
ocnOTNPayloadMismatchCondAn OTN payload mismatch is active on the facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.25
ocnOTNPayloadMismatchClearA previously active OTN payload mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.26
ocnForcedSwitchToProtectionCondThe active line of a protected line pair has been forced to switch to the Protection line.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.27
ocnForcedSwitchToProtectionClearA previously active Forced Switch To Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.28
ocnForcedSwitchToWorkingCondThe active line of a protected line pair has been forced to switch to the Working line.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.29
ocnForcedSwitchToWorkingClearA previously active Forced Switch To Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.30
ocnLockoutProtectionCondThe Protection line of a protected line pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.31
ocnLockoutProtectionClearA previously active Lockout Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.32
ocnLockoutWorkingCondThe Working line of a protected line pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.33
ocnLockoutWorkingClearA previously active Lockout Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.34
ocnWavelengthNotAchievableCondThe tunable pluggable cannot be tuned to the provisioned wavelength.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.35
ocnWavelengthNotAchievableClearA previously active Wavelength Not Achievable condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.12.0.36
stsnCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.13
stsnAlarmIndicationSignalCondA Path-level Alarm Indication Signal indication is active on the STS-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.1
stsnAlarmIndicationSignalClearA previously active STS-N Alarm Indication Signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.2
stsnLossOfPointerCondA Loss of Pointer condition is active on the STS-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.3
stsnLossOfPointerClearA previously raised STS-N Loss of Pointer condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.4
stsnUnequippedCondAn Unequipped indication has been detected for the STS-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.5
stsnUnequippedClearA previously raised STS-N Unequipped condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.6
stsnSignalDegradeCondA signal degrade condition on the STS-N channel is active. This indicates that the detected bit error rate exceeds the degrade threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.7
stsnSignalDegradeClearA previously raised STS-N signal degrade condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.8
stsnForcedSwitchToProtectionCondThe active STS-N channel of a protected STS-N channel pair has been forced to switch to the Protection transceiver.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.9
stsnForcedSwitchToProtectionClearA previously raised STS-N Forced Switch To Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.10
stsnForcedSwitchToWorkingCondThe active STS-N channel of a protected STS-N channel pair has been forced to switch to the Working transceiver.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.11
stsnForcedSwitchToWorkingClearA previously raised STS-N Forced Switch To Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.12
stsnLockoutProtectionCondThe Protection STS-N channel of a protected STS-N channel pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.13
stsnLockoutProtectionClearA previously raised STS-N Lockout Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.14
stsnLockoutWorkingCondThe Working STS-N channel of a protected STS-N channel pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.15
stsnLockoutWorkingClearA previously raised STS-N Lockout Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.16
stsnConcatMismatchCondA connection provisioning does not match has been detected for the STS-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.17
stsnConcatMismatchClearA previously raised STS-N Concat Mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.13.0.18
stmnCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.14
stmnLossOfSignalCondThis notification indicates that there is no input signal detected on the STM-N port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.1
stmnLossOfSignalClearThis notification indicates that a previously active STM-N Loss of Signal condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.2
stmnXcvrMismatchCondThere is a mismatch between the SFP or XFP transceiver provisioned for the STM-N facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the STM-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.3
stmnXcvrMismatchClearA previously active STM-N Mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.4
stmnOpticalPwrReceivedMinCondIndicates that the input power for the STM-N facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.5
stmnOpticalPwrReceivedMinClearA previously active STM-N minimum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.6
stmnOpticalPwrReceivedMaxCondIndicates that the input power for the STM-N facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.7
stmnOpticalPwrReceivedMaxClearA previously active STM-N maximum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.8
stmnOpticalPwrTransmittedMinCondIndicates that the output power for the STM-N facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.9
stmnOpticalPwrTransmittedMinClearA previously active STM-N minimum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.10
stmnOpticalPwrTransmittedMaxCondIndicates that the output power for the STM-N facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.11
stmnOpticalPwrTransmittedMaxClearA previously active STM-N maximum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.12
stmnLossOfFrameCondAn STM-N Loss of Frame condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.13
stmnLossOfFrameClearA previously active STM-N Loss of Frame condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.14
stmnSignalDegradeCondA signal degrade condition on the STM-N facility is active. This indicates that the detected bit error rate exceeds the degrade threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.15
stmnSignalDegradeClearA previously active STM-N Signal Degrade condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.16
stmnAlarmIndicationSignalCondAn STM-N Line-level Alarm Indication Signal indication is active on facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.17
stmnAlarmIndicationSignalClearA previously active STM-N Alarm Indication Signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.18
stmnLoopbackCondIndicates that the STM-N facility has been provisioned to enter loopback mode.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.19
stmnLoopbackClearA previously active loopback condition on the STM-N facility has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.20
stmnLossOfPrimaryTimingReferenceCondIndicates that the primary timing reference signal for the identified STM-N facility is missing or faulty and cannot be locked on.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.21
stmnLossOfPrimaryTimingReferenceClearA previously active STM-N Loss of Primary Timing Reference condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.22
stmnLossOfSecondaryTimingReferenceCondIndicates that the secondary timing reference signal for the identified STM-N facility is missing or faulty and cannot be locked on.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.23
stmnLossOfSecondaryTimingReferenceClearA previously active STM-N Loss of Secondary Timing Reference condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.24
stmnOTNPayloadMismatchCondAn OTN payload mismatch is active on the facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.25
stmnOTNPayloadMismatchClearA previously active OTN payload mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.26
stmnForcedSwitchToProtectionCondThe active line of a protected line pair has been forced to switch to the Protection line.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.27
stmnForcedSwitchToProtectionClearA previously active Forced Switch To Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.28
stmnForcedSwitchToWorkingCondThe active line of a protected line pair has been forced to switch to the Working line.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.29
stmnForcedSwitchToWorkingClearA previously active Forced Switch To Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.30
stmnLockoutProtectionCondThe Protection line of a protected line pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.31
stmnLockoutProtectionClearA previously active Lockout Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.32
stmnLockoutWorkingCondThe Working line of a protected line pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.33
stmnLockoutWorkingClearA previously active Lockout Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.34
stmnWavelengthNotAchievableCondA previously active Wavelength Not Achievable condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.35
stmnWavelengthNotAchievableClearA previously active Lockout Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.14.0.36
vcnCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.15
vcnAlarmIndicationSignalCondA Path-level Alarm Indication Signal indication is active on the VC-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.1
vcnAlarmIndicationSignalClearA previously active VC-N Alarm Indication Signal condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.2
vcnLossOfPointerCondA Loss of Pointer condition is active on the VC-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.3
vcnLossOfPointerClearA previously raised VC-N Loss of Pointer condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.4
vcnUnequippedCondAn Unequipped indication has been detected for the VC-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.5
vcnUnequippedClearA previously raised VC-N Unequipped condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.6
vcnSignalDegradeCondA signal degrade condition on the VC-N channel is active. This indicates that the detected bit error rate exceeds the degrade threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.7
vcnSignalDegradeClearA previously raised VC-N signal degrade condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.8
vcnForcedSwitchToProtectionCondThe active VC-N channel of a protected VC-N channel pair has been forced to switch to the Protection transceiver.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.9
vcnForcedSwitchToProtectionClearA previously raised VC-N Forced Switch To Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.10
vcnForcedSwitchToWorkingCondThe active VC-N channel of a protected VC-N channel pair has been forced to switch to the Working transceiver.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.11
vcnForcedSwitchToWorkingClearA previously raised VC-N Forced Switch To Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.12
vcnLockoutProtectionCondThe Protection VC-N channel of a protected VC-N channel pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.13
vcnLockoutProtectionClearA previously raised VC-N Lockout Protection condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.14
vcnLockoutWorkingCondThe Working VC-N channel of a protected VC-N channel pair has been locked out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.15
vcnLockoutWorkingClearA previously raised VC-N Lockout Working condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.16
vcnConcatMismatchCondA connection provisioning does not match has been detected for the VC-N channel.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.17
vcnConcatMismatchClearA previously raised VC-N Concat Mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.15.0.18
geCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.16
geLossOfSignalCondThis notification indicates that there is no input signal detected on the Gigabit Ethernet port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.1
geLossOfSignalClearThis notification indicates that a previously active GE Loss of Signal condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.2
geXcvrMismatchCondThere is a mismatch between the SFP or XFP transceiver provisioned for the Gigabit Ethernet facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the GE facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.3
geXcvrMismatchClearA previously active GE Mistmatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.4
geOpticalPwrReceivedMinCondIndicates that the input power for the Gigabit Ethernet facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.5
geOpticalPwrReceivedMinClearA previously active GE minimum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.6
geOpticalPwrReceivedMaxCondIndicates that the input power for the Gigabity Ethernet facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.7
geOpticalPwrReceivedMaxClearA previously active GE maximum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.8
geOpticalPwrTransmittedMinCondIndicates that the output power for the Gigabit Ethernet facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.9
geOpticalPwrTransmittedMinClearA previously active GE minimum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.10
geOpticalPwrTransmittedMaxCondIndicates that the output power for the Gigabit Ethernet facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.11
geOpticalPwrTransmittedMaxClearA previously active GE maximum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.12
geLossOfSyncCondA Gigabit Ethernet Loss of Synchronization condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.13
geLossOfSyncClearA previously active Gigabit Ethernet Loss of Synchronization condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.14
geRemotePathFailureCondA Gigabit Ethernet Remote Path Failure condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.15
geRemotePathFailureClearA previously active GE Remote Path Failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.16
geLossOfMultiframeCondA Loss of Multiframe condition is active against the VCG that is mapped to the identified Gigabit Ethernet port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.17
geLossOfMultiframeClearA previously raised GE Loss of Multiframe condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.18
geLossOfSequenceCondA Loss of Sequence condition is active against the VCG that is mapped to the identified Gigabit Ethernet port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.19
geLossOfSequenceClearA previously active GE Loss of Sequence condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.20
geLossOfAlignmentCondA Loss of Alignment condition is active against the VCG that is mapped to the identified Gigabit Ethernet port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.21
geLossOfAlignmentClearA previously active GE Loss of Alignment condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.22
geLoopbackCondIndicates that the Gigabit Ethernet facility has been provisioned to enter loopback mode.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.23
geLoopbackClearA previously active GE Loopback condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.24
geBandwidthMismatchCondA GE bandwidth mismatch condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.25
geBandwidthMismatchClearA previously active GE bandwidth mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.26
gePayloadMismatchCondA GE payload mismatch condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.27
gePayloadMismatchClearA previously active GE payload mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.16.0.28
fcCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.17
fcLossOfSignalCondThis notification indicates that there is no input signal detected on the Fiber Channel port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.1
fcLossOfSignalClearThis notification indicates that a previously active FC Loss of Signal condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.2
fcXcvrMismatchCondThere is a mismatch between the SFP or XFP transceiver provisioned for the Fiber Channel facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the FC facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.3
fcXcvrMismatchClearA previously active FC XCVR Mistmatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.4
fcOpticalPwrReceivedMinCondIndicates that the input power for the Fiber Channel facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.5
fcOpticalPwrReceivedMinClearA previously active FC minimum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.6
fcOpticalPwrReceivedMaxCondIndicates that the input power for the Fiber Channel facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.7
fcOpticalPwrReceivedMaxClearA previously active FC maximum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.8
fcOpticalPwrTransmittedMinCondIndicates that the output power for the Fiber Channel facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.9
fcOpticalPwrTransmittedMinClearA previously active FC minimum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.10
fcOpticalPwrTransmittedMaxCondIndicates that the output power for the Fiber Channel facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.11
fcOpticalPwrTransmittedMaxClearA previously active FC maximum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.12
fcLossOfSyncCondA Fiber Channel Loss of Synchronization condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.13
fcLossOfSyncClearA previously active Fiber Channel Loss of Synchronization condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.14
fcRemotePathFailureCondA Fiber Channel Remote Path Failure condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.15
fcRemotePathFailureClearA previously active FC Remote Path Failure condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.16
fcLossOfMultiframeCondA Loss of Multiframe condition is active against the VCG that is mapped to the identified Fiber Channel port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.17
fcLossOfMultiframeClearA previously raised FC Loss of Multiframe condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.18
fcLossOfSequenceCondA Loss of Sequence condition is active against the VCG that is mapped to the identified Fiber Channel port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.19
fcLossOfSequenceClearA previously active FC Loss of Sequence condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.20
fcLossOfAlignmentCondA Loss of Alignment condition is active against the VCG that is mapped to the identified Fiber Channel port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.21
fcLossOfAlignmentClearA previously active FC Loss of Alignment condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.22
fcLoopbackCondIndicates that the Fiber Channel facility has been provisioned to enter loopback mode.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.23
fcLoopbackClearA previously active FC Loopback condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.24
fcBandwidthMismatchCondA Fiber Channel bandwidth mismatch condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.25
fcBandwidthMismatchClearA previously active Fiber Channel bandwidth mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.26
fcPayloadMismatchCondA Fiber Channel payload mismatch condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.27
fcPayloadMismatchClearA previously active Fiber Channel payload mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.17.0.28
ethPortCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.20
olsSFPMissingCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.1
olsSFPMissingClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.2
olsSFPMismatchCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.3
olsSFPMismatchClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.4
olsInputLOSCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.5
olsInputLOSClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.6
olsOpticalPwrReceivedMinCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.7
olsOpticalPwrReceivedMinClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.8
olsOpticalPwrReceivedMaxCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.9
olsOpticalPwrReceivedMaxClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.10
olsOpticalPwrTransmittedMinCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.11
olsOpticalPwrTransmittedMinClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.12
olsOpticalPwrTransmittedMaxCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.13
olsOpticalPwrTransmittedMaxClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.14
olsTemperatureMaxCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.15
olsTemperatureMaxClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.16
olsLoopbackCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.17
olsLoopbackClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.18
olsLossOfSyncCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.19
olsLossOfSyncClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.20
olsLossOfFrameCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.21
olsLossOfFrameClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.22
olsAlarmIndicationSignalCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.23
olsAlarmIndicationSignalClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.24
olsBackwardDefectIndicatorCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.25
olsBackwardDefectIndicatorClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.26
olsSignalDegradeCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.27
olsSignalDegradeClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.28
olsOTNPayloadMismatchCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.29
olsOTNPayloadMismatchClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.30
olsOTUTrailTraceMismatchCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.31
olsOTUTrailTraceMismatchClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.32
olsRemoteFaultCondA remote fault indication is active on the ethernet interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.33
olsRemoteFaultClearA previously raised remote fault indication has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.34
olsLocalFaultCondA local fault indication is active on the ethernet interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.35
olsLocalFaultClearA previously raised local fault indication has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.36
olsWavelengthNotAchievableCond
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.37
olsWavelengthNotAchievableClear
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.20.0.38
pvxL2PortCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.21
olsLinkDownCondPVX L2 port link down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.21.0.1
olsLinkDownClearPVX L2 port link down has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.21.0.2
mstpCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.22
lagCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.23
odunCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.24
odunPayloadMismatchCondA payload mismatch is active on the ODU-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.24.0.1
odunPayloadMismatchClearA previously active ODU-N facility payload mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.24.0.2
odunOpenConnectionIndicatorCondAn OCI is active on the ODU-N facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.24.0.3
odunOpenConnectionIndicatorClearA previously active ODU-N OCI condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.24.0.4
briCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.25
briLossOfSignalCondThis notification indicates that there is no input signal detected on the BRI port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.1
briLossOfSignalClearThis notification indicates that a previously active BRI Loss of Signal condition has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.2
briXcvrMismatchCondThere is a mismatch between the SFP or XFP transceiver provisioned for the BRI facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the BRI facility.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.3
briXcvrMismatchClearA previously active BRI XCVR Mistmatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.4
briOpticalPwrReceivedMinCondIndicates that the input power for the BRI facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.5
briOpticalPwrReceivedMinClearA previously active BRI minimum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.6
briOpticalPwrReceivedMaxCondIndicates that the input power for the BRI facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.7
briOpticalPwrReceivedMaxClearA previously active BRI maximum power recieved condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.8
briOpticalPwrTransmittedMinCondIndicates that the output power for the BRI facility has fallen below the minimum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.9
briOpticalPwrTransmittedMinClearA previously active BRI minimum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.10
briOpticalPwrTransmittedMaxCondIndicates that the output power for the BRI facility has risen above the maximum threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.11
briOpticalPwrTransmittedMaxClearA previously active BRI maximum power transmitted condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.12
briLossOfMultiframeCondA Loss of Multiframe condition is active against the VCG that is mapped to the identified BRI port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.13
briLossOfMultiframeClearA previously raised BRI Loss of Multiframe condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.14
briLossOfSequenceCondA Loss of Sequence condition is active against the VCG that is mapped to the identified BRI port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.15
briLossOfSequenceClearA previously active BRI Loss of Sequence condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.16
briLossOfAlignmentCondA Loss of Alignment condition is active against the VCG that is mapped to the identified BRI port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.17
briLossOfAlignmentClearA previously active BRI Loss of Alignment condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.18
briLoopbackCondIndicates that the BRI facility has been provisioned to enter loopback mode.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.19
briLoopbackClearA previously active BRI Loopback condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.20
briBandwidthMismatchCondA BRI bandwidth mismatch condition is active on the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.21
briBandwidthMismatchClearA previously active BRI bandwidth mismatch condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.22
briLossOfLockCondThis alarm indicates that a BRI port is unable to lock on the incoming bit stream. This is a result of either: the provisioned protocol does not match the incoming signal, or the incoming signal is excessively degraded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.23
briLossOfLockClearA previously active BRI loss of lock condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.24
briTxLockingCondThis alarm indicates that a BRI client port is in the process of locking on the signal in the transmit direction.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.25
briTxLockingClearA previously active BRI TX locking condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.25.0.26
ntpcCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.26
ntpAssocSrvrNotReachableCondThis alarm indicates that an NTP server can not be reached. This is a result of either: an invalid IP address, network problems or the server is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.26.0.1
ntpAssocSrvrNotReachableClearA previously active NTP server not reachable condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.26.0.2
ntpAssocSrvrNotRespondingCondThis alarm indicates that an NTP server is reachable but is not responding to the NTP requests correctly. This can be a result of either: the server does not have the service running or there is a server is having problems.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.26.0.3
ntpAssocSrvrNotRespondingClearA previously active NTP server not responding condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.26.0.4
ntpAssocAuthenFailedCondThis alarm indicates that NTP authentication has failed. This can be a result of either: the key is configured incorrectly on the client side or the NTP server does not accept the key.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.26.0.5
ntpAssocAuthenFailedClearA previously active NTP authentication failed condition has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.26.0.6
envCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.27
envAttrUnsupportedCondIndicates that an environmental alarm detection is configured against a housekeeping input port which is located on equipment which does not support the configured function.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.1
envAttrUnsupportedClearA previously active environmental attribute unsupported alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.2
envAirComprCondIndicates that an environmental air compressor failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.3
envAirComprClearA previously active environmental air compressor failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.4
envAirCondCondIndicates that an environmental air conditioning failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.5
envAirCondClearA previously active environmental air conditioning failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.6
envAirDryrCondIndicates that an environmental air dryer failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.7
envAirDryrClearA previously active environmental air dryer failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.8
envBatDschrdCondIndicates that an environmental battery discharging alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.9
envBatDschrdClearA previously active environmental battery discharging alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.10
envBatteryCondIndicates that an environmental battery failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.11
envBatteryClearA previously active environmental battery failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.12
envClFanCondIndicates that an environmental cooling fan failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.13
envClFanClearA previously active environmental cooling fan failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.14
envCpMajorCondIndicates that an environmental centralized power major alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.15
envCpMajorClearA previously active environmental centralized power major alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.16
envCpMinorCondIndicates that an environmental centralized power minor alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.17
envCpMinorClearA previously active environmental centralized power minor alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.18
envDoorOpenCondIndicates that an environmental door open alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.19
envDoorOpenClearA previously active environmental door open alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.20
envEngineCondIndicates that an environmental engine failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.21
envEngineClearA previously active environmental engine failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.22
envEngOprgCondIndicates that an environmental engine operating alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.23
envEngOprgClearA previously active environmental engine operating alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.24
envExplGsCondIndicates that an environmental explosive gas alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.25
envExplGsClearA previously active environmental explosive gas alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.26
envFirDetrCondIndicates that an environmental fire detector failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.27
envFirDetrClearA previously active environmental fire detector failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.28
envFireCondIndicates that an environmental fire alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.29
envFireClearA previously active environmental fire alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.30
envFloodCondIndicates that an environmental flood alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.31
envFloodClearA previously active environmental flood alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.32
envFuseCondIndicates that an environmental fuse alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.33
envFuseClearA previously active environmental fuse alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.34
envGenCondIndicates that an environmental generator failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.35
envGenClearA previously active environmental generator failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.36
envGenericCondIndicates that an environmental generic alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.37
envGenericClearA previously active environmental generic alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.38
envHiAirCondIndicates that an environmental high airflow alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.39
envHiAirClearA previously active environmental high airflow alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.40
envHiHumCondIndicates that an environmental high humidity alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.41
envHiHumClearA previously active environmental high humidity alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.42
envHiTempCondIndicates that an environmental high temperature alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.43
envHiTempClearA previously active environmental high temperature alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.44
envHiWindCondIndicates that an environmental high wind alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.45
envHiWindClearA previously active environmental high wind alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.46
envHiWtrCondIndicates that an environmental high water alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.47
envHiWtrClearA previously active environmental high water alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.48
envIceBuildupCondIndicates that an environmental ice buildup alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.49
envIceBuildupClearA previously active environmental ice buildup alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.50
envIntruderCondIndicates that an environmental intrusion alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.51
envIntruderClearA previously active environmental intrusion alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.52
envLwBatvgCondIndicates that an environmental low battery voltage alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.53
envLwBatvgClearA previously active environmental low battery voltage alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.54
envLwFuelCondIndicates that an environmental low fuel alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.55
envLwFuelClearA previously active environmental low fuel alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.56
envLwHumCondIndicates that an environmental low humidity alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.57
envLwHumClearA previously active environmental low humidity alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.58
envLwPresCondIndicates that an environmental low cable pressure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.59
envLwPresClearA previously active environmental low cable pressure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.60
envLwTempCondIndicates that an environmental low temperature alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.61
envLwTempClearA previously active environmental low temperature alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.62
envLwWtrCondIndicates that an environmental low water alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.63
envLwWtrClearA previously active environmental low water alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.64
envMiscCondIndicates that an environmental miscellaneous alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.65
envMiscClearA previously active environmental miscellaneous alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.66
envOpenDrCondIndicates that an environmental open door alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.67
envOpenDrClearA previously active environmental open door alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.68
envPowerCondIndicates that an environmental power failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.69
envPowerClearA previously active environmental power failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.70
envPumpCondIndicates that an environmental pump failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.71
envPumpClearA previously active environmental pump failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.72
envRectCondIndicates that an environmental rectifier failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.73
envRectClearA previously active environmental rectifier failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.74
envRectHiCondIndicates that an environmental rectifier high voltage alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.75
envRectHiClearA previously active environmental rectifier high voltage alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.76
envRectLoCondIndicates that an environmental rectifier low voltage alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.77
envRectLoClearA previously active environmental rectifier low voltage alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.78
envSmokeCondIndicates that an environmental smoke alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.79
envSmokeClearA previously active environmental smoke alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.80
envToxicGasCondIndicates that an environmental toxic gas alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.81
envToxicGasClearA previously active environmental toxic gas alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.82
envVentnCondIndicates that an environmental ventilation system failure alarm is raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.83
envVentnClearA previously active environmental ventilation system failure alarm has cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.2.27.0.84
olCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.28
erpsCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.29
swMemberCondNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.2.30
dbChangeNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.3
dbChangeEvtThis message indicates that a change has been made in the value of the provisioned object identified by the dbChangeOID Var-Bind. If multiple objects have been changed in the same transaction, there will be multiple occurrances of the dbChangeOID object listed in the Var-Bind list.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.3.0.2
dbChangeSecuEvtThis message indicates that a change has been made in the value of the SNMP community string, SNMP trap reciever, or Tl1User.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18070.2.2.2.3.0.3
dbChangeNotificationsObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.3.1
dbChangeDateAndTimeThe date and time at which a database change notification was issued by the system.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.18070.2.2.2.3.1.1
dbChangeSeqNumA integer value indicating the place of a database change notification message within the continual sequence of all database messages issued by the system.ro
Unsigned32
.1.3.6.1.4.1.18070.2.2.2.3.1.2
dbChangeOIDThe OID of the object instance whose value has been changed in the database.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.3.1.3
notificationObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.4
trapSeqNumA integer value indicating the place of the trap notification message within the continual sequence of all notification messages issued by the system.ro
Unsigned32
.1.3.6.1.4.1.18070.2.2.2.4.1
notificationControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.5
condNotifCtrl
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.5.1
condNotifCtrlTableThis table contains one row for every condition notification associated with a raise.
SEQUENCE OF CondNotifCtrlEntry
.1.3.6.1.4.1.18070.2.2.2.5.1.1
condNotifCtrlEntryThe conceptual row object of the condition notification control table.
CondNotifCtrlEntry
.1.3.6.1.4.1.18070.2.2.2.5.1.1.1
condNotifObjIdThe specific condition notification to set the severity for. The value must correspond to the raise condition not the clear.
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.5.1.1.1.1
condNotifSeverityThe severity associated with the condition notification. - Only certain values are permitted for the set: default, critial, major, minor, notAlarmed. - Only certain values are visible for the get: critial, major, minor, major-minor, notAlarmedrw
CondSeverity
.1.3.6.1.4.1.18070.2.2.2.5.1.1.1.2
condNotifDefaultSeverityThe default severity associated with the condition notification. Only certain of the CondSeverity values are visible: critial, major, minor, major-minor, notAlarmedro
CondSeverity
.1.3.6.1.4.1.18070.2.2.2.5.1.1.1.3
envCondAttrTableThis table is used to manage the configuration of environmental alarm inputs. It contains one row for each environmental condition input on the NE.
SEQUENCE OF EnvCondAttrEntry
.1.3.6.1.4.1.18070.2.2.2.5.1.2
envCondAttrEntryThe conceptual row object of the environmental condition attribute table.
EnvCondAttrEntry
.1.3.6.1.4.1.18070.2.2.2.5.1.2.1
envCondAttrHKIIdxThe number of the housekeeping input which drives the activation of the environmental condition configured by this entry of the table.
INTEGER
.1.3.6.1.4.1.18070.2.2.2.5.1.2.1.1
envCondAttrSeverityThe severity reported for the configured environmental condition when it is raised. The valid values are: - minor - major - critical - notAlarmedrw
CondSeverity
.1.3.6.1.4.1.18070.2.2.2.5.1.2.1.2
envCondAttrCodeTypeThe code for the specific environmental condition that is reported when the housekeeping input indicates that the condition is active.rw
EnvNotifCodeType
.1.3.6.1.4.1.18070.2.2.2.5.1.2.1.3
envCondAttrDescriptionThe textual decription of the environmental condition that is reported when the condition is raised.rw
DisplayString
.1.3.6.1.4.1.18070.2.2.2.5.1.2.1.4
envCondAttrInputTypeSpecifies how the housekeeping input which drives the reporting of the environmental condition is interpreted.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.2.5.1.2.1.5
eventNotifCtrl
OBJECT IDENTIFIER
.1.3.6.1.4.1.18070.2.2.2.5.2
eventNotifStateAllows all events to be either disabled or enabled.rw
Enumeration
.1.3.6.1.4.1.18070.2.2.2.5.2.1