BSUMSUBNETS-MIB
Imported Objects
Objects
5 total| Object Name |
|---|
aniBsuMultSubnetsThis group gives the BSU Multiple Subnets information. The aniBsuSubnetConfTable is used to view and configure subnets per wireless port. There can be upto 1024 <Ip Address/Subnet Mask> pairs. For a given WSS port, there can be multiple and different subnets. This means that each subnet specified by an <Ip Address masked by the Subnet Mask> has to be distinct. Atleast one Ip Address and Subnet Mask has to be specified. In addition to the subnet being distinct, each IP Address must be unique too. If clustering is disabled, then Multiple Subnets on one WSS port should not clash with Multiple Subnets on any other WSS port. Clustering and multiple subnets can exists simultaneously as long as they are not on the same WSS. If clustering is enabled but not all WSS are clustered, then those that are not part of the cluster can have multiple subnets. Eg. If WSS1 and WSS2 are clustered, but WSS3 and WSS4 are not, then WSS3 and WSS4 can have multiple subnets. To add a new subnet to the table, first set the aniBsuSubnetConfAddr. Next send an SNMP set request on aniBsuSubnetConfMask. Currently, deletion and modification of entries is not supported. When the BSU is in Bridge mode, this multiple subnets table is not valid and will not be displayed. MODULE-IDENTITY .1.3.6.1.4.1.4325.3.6 |
aniBsuSubnetConfTableThis table contains the Multiple Subnets information per wireless port. SEQUENCE OF AniBsuSubnetConfEntry .1.3.6.1.4.1.4325.3.6.1 |
aniBsuSubnetConfEntryAn entry in the aniBsuSubnetConfTable. AniBsuSubnetConfEntry .1.3.6.1.4.1.4325.3.6.1.1 |
aniBsuSubnetConfAddrThe IP Address of the configured Subnet.rw IpAddress .1.3.6.1.4.1.4325.3.6.1.1.1 |
aniBsuSubnetConfMaskThe Subnet Mask.rw IpAddress .1.3.6.1.4.1.4325.3.6.1.1.2 |
More MIBs from Ani
Browse all AniMIBs →SNMP MIB module
The DEVTRAPS-MIB defines the standard set of SNMP trap definitions used to notify network management systems of critical device events, such as link state changes, hardware failures, and system reboots. It serves as the foundational protocol interface for asynchronous alerting across generic network infrastructure devices, enabling real-time fault detection without requiring active polling.
Standard SNMP MIB module defining data structures for ANIROOT-MIB.
SNMP MIB module
The BSUSTATS-MIB module monitors RF port-level performance, bandwidth allocation, and signal quality metrics for Broadcom (formerly Enterasys) Broadband Service Units (BSUs). It provides specific counters for RF statistics, bandwidth groups, and signal quality tables to facilitate the analysis of cable modem termination system (CMTS) or DOCSIS network health.
The BSUSUSTATUS-MIB enables SNMP monitoring of BSU (Broadband Service Unit) hardware to track the operational state and link status of both upstream and downstream SU (Subscriber Unit) connections via dedicated status tables.