8 total| Object Name |
|---|
aniBsuClockThis module is used to configure the clock time on the BSU. BSUs need to obtain and set their current clock time at boot up. Sus will communicate with the BSU during their own boot up and set their own clock time to that of BSU. Time at the BSU can be set either through SNTP or manually. It is recommended to use SNTP to obtain time. MODULE-IDENTITY .1.3.6.1.4.1.4325.3.4 |
aniBsuClkSntpTimeZoneThis is used to set the appropriate Time Zone offset from GMT. The format of data should be +Hour:Min or -Hour:Min. The valid Hour should be between -13 to +14 The valid Min should be 00,15,30 or 45 For example: +12:00 or +12:30 or -3:45rw DisplayString .1.3.6.1.4.1.4325.3.4.1 |
aniBsuClkSntpDstEnableThis shows whether Daylight Saving is enabled or not. It gives user the option to incorporate Daylight Saving Time in the configuration.rw Enumeration .1.3.6.1.4.1.4325.3.4.2 |
aniBsuClkSntpDstStartUsed to specify the start of Daylight Saving Time which should be entered in the 'mmddhh' format where m - month, d - day and h - hour. Can and must be set only if aniBsuClkSntpDstEnable is enabled.rw DisplayString .1.3.6.1.4.1.4325.3.4.3 |
aniBsuClkSntpDstEndUsed to specify the end of Daylight Saving Time which should be entered in the 'mmddhh' format where m - month, d - day and h - hour. Can and must be set only if aniBsuClkSntpDstEnable is enabled.rw DisplayString .1.3.6.1.4.1.4325.3.4.4 |
aniBsuClkSntpEnableThis flag is used to enable(1) or disable(2) SNTP. It is recommended to use SNTP rather than manually setting the time to avoid errors in clock times simply due to manual entry across various BSUs.rw Enumeration .1.3.6.1.4.1.4325.3.4.5 |
aniBsuClkManualTimeUsed to specify the local clock time manually. It should be entered in the 'mm/dd/yyyy hh:mm:ss' format that is, month/day/year hour:minute:second. When the user sends a set request on this parameter, the aniBsuClkSntpEnable value is automatically set to disable(2), to set this manual time entry on BSU.rw DisplayString .1.3.6.1.4.1.4325.3.4.6 |
aniBsuClkCurrentTimeThe Current Time in 'mm/dd/yy hh:mm:ss' format, that is, month/day/year hour:minute:second.ro DisplayString .1.3.6.1.4.1.4325.3.4.7 |
More MIBs from Ani
Browse all AniMIBs →SNMP MIB module
The DEVTRAPS-MIB defines the standard set of SNMP trap definitions used to notify network management systems of critical device events, such as link state changes, hardware failures, and system reboots. It serves as the foundational protocol interface for asynchronous alerting across generic network infrastructure devices, enabling real-time fault detection without requiring active polling.
Standard SNMP MIB module defining data structures for ANIROOT-MIB.
SNMP MIB module
The BSUSTATS-MIB module monitors RF port-level performance, bandwidth allocation, and signal quality metrics for Broadcom (formerly Enterasys) Broadband Service Units (BSUs). It provides specific counters for RF statistics, bandwidth groups, and signal quality tables to facilitate the analysis of cable modem termination system (CMTS) or DOCSIS network health.
The BSUSUSTATUS-MIB enables SNMP monitoring of BSU (Broadband Service Unit) hardware to track the operational state and link status of both upstream and downstream SU (Subscriber Unit) connections via dedicated status tables.