BSC3270-OPT-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
80
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
80 total| Object Name |
|---|
codex OBJECT IDENTIFIER .1.3.6.1.4.1.449 |
RFC1155-SMI Unknown .1.3.6.1.4.1.449 |
cdxProductSpecific OBJECT IDENTIFIER .1.3.6.1.4.1.449.2 |
cdx6500 OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1 |
cdx6500Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2 |
cdx6500CfgProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.1 |
cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.1.1 |
cdx6500PPCTBSC3270PortTableA table of BSC3270 Port configuration entries. SEQUENCE OF Cdx6500PPCTBSC3270PortEntry .1.3.6.1.4.1.449.2.1.2.1.1.10 |
cdx6500PPCTBSC3270PortEntryA BSC3270 Port Configuration Table entry. Each entry
contains the configuration parameters for a single
BSC3270 port. Cdx6500PPCTBSC3270PortEntry .1.3.6.1.4.1.449.2.1.2.1.1.10.1 |
cdx6500BSC3270PortNumberThe BSC3270 port number described by this entry.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.1 |
cdx6500BSC3270PADTypeIndicates whether the port is functioning as a
Terminal PAD (tpad) or a Host PAD (hpad).
newvalTpad - same functionality as 'tpad', new enumeration
introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.2 |
cdx6500BSC3270ClockSourceint - internal clock source.
ext - external clock source.
newvalInt - same functionality as 'int', new enumeration
introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.3 |
cdx6500BSC3270ClockSpeedThis is the speed of the port in bits per second,
when using internal clocking.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.4 |
cdx6500BSC3270ContentionIndicates whether Half Duplex (hdx) or
Full Duplex (fdx) modem signals are being generated.
Full Duplex indicates communication is occuring
in both directions simultaneously between devices.
Half Duplex indicates transmission is occuring
in both directions, but only in one direction
at a time.
newvalHdx : same functionality as 'hdx', new enumeration
introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.5 |
cdx6500BSC3270NumDevicesSpecifies the number of physical devices on this line.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.6 |
cdx6500BSC3270ServTimerThe Service Timer specifies the interval of time in
seconds between periodic servicing. Such servicing
includes intervals between the time the PAD will
attempt to poll devices that previously failed to
respond and intervals between failures in attempts
to establish a connection from a device configured
for Autocall.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.7 |
cdx6500BSC3270ErrThreshCountIndicates number of consecutive errors that can occur
before a device is considered down.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.8 |
cdx6500BSC3270ResponseTimeoutSpecifies the amount of time in seconds that the TPAD
will wait for a response from a device before it
attempts to re-poll the non-responding device. The
TPAD will continue to re-poll the device until the
Error Threshold Count is reached. The device will then
be polled based on the value of the Service Timer. For
a Host PAD it specifies the amount of time in seconds
that the HPAD will wait for a Host response before it
requests a response retransmission.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.9 |
cdx6500BSC3270HostPADTimeoutSpecifies the amount of time in seconds that the HPAD
will wait for the host to poll a device. If the time
limit is exceeded, the HPAD will consider the device
to be inactive, and will not permit any physical
device on a TPAD to establish a call to that address
on the HPAD.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.10 |
cdx6500BSC3270InterBuffTimeoutSpecifies the maximum amount of time in seconds the PAD
will wait for the end of a multi-packet message from the
network. If this time limit is exceeded, the PAD will
abort the entire message and request retransmission.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.11 |
cdx6500BSC3270IdleDevTimeoutSpecifies the amount of time in minutes that the TPAD
will wait for user data from a device after an X.25
call has been established, before disconnecting the
call. The parameter is applicable to devices configured
as Originators. This parameter will not bring down a
call established in Autocall mode. It is recommended
that relatively inactive devices that are configured
for Autocall be reconfigured for Fast Connect.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.12 |
cdx6500BSC3270PrintDisconTimerSpecifies the amount of time in seconds that an X.25 call
to a Printer device is disconnected after a period of
inactivity.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.10.1.13 |
cdx6500BSC3270SignonKeyThis parameter assignes a Function Key that will be used
to generate a connection. This parameter is applicable
to a TPAD port only. This parameter is not applicable for
devices configured for Autocall.
Valid decimal codes are :
pf1 - 241 pf9 - 249 pf17 - 197
pf2 - 242 pf10 - 122 pf18 - 198
pf3 - 243 pf11 - 123 pf19 - 199
pf4 - 244 pf12 - 124 pf20 - 200
pf5 - 245 pf13 - 193 pf21 - 201
pf6 - 246 pf14 - 194 pf22 - 74
pf7 - 247 pf15 - 195 pf23 - 75
pf8 - 248 pf16 - 196 pf24 - 76
Any other value will cause error.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.14 |
cdx6500BSC3270DiscKeyThis parameter allows assignment of the Function Key
needed to clear the current session. This parameter is
applicable to a TPAD port only. This parameter is not
applicable for devices configured for Autocall.
Valid decimal codes are :
pf1 - 241 pf9 - 249 pf17 - 197
pf2 - 242 pf10 - 122 pf18 - 198
pf3 - 243 pf11 - 123 pf19 - 199
pf4 - 244 pf12 - 124 pf20 - 200
pf5 - 245 pf13 - 193 pf21 - 201
pf6 - 246 pf14 - 194 pf22 - 74
pf7 - 247 pf15 - 195 pf23 - 75
pf8 - 248 pf16 - 196 pf24 - 76
Any other value will cause error.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.15 |
cdx6500BSC3270CharSetIndicates whether Terminal/Printer devices on this port
support an ascii or ebcdic character set.
newvalAscii : same functionality as 'ascii', new enumeration
introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.16 |
cdx6500BSC3270PortSubAddrCalls addressed to this node and with this subaddress
will be routed to this port.ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.10.1.17 |
cdx6500BSC3270PortOptionsSelect options on this BSC3270 port as follows:
NONE - no option specified
CESS - Turn the polling cessation option ON. In the
HPAD, a G-POLL will not be responded to if
none of the terminals configured on that
controller are in a connected state (ie. no
SVC in place) and there are no printers
configured on that controller. A S-POLL or
SELECT or a data message to a terminal will
not be responded to if that device is not in
a connected state. In the TPAD, devices that
are configured for AUTO+ORG will be polled
only once per service timer interval until the
connection (SVC) to the remote HPAD is
established.
SINGLE - Turn single message delivery option ON. The
Hpad will transmit only one complete message
(single or multiple block message) when
responding to a Specific or a General Poll.
This option applies only to Hpad ports.
Any combination of above specified by summing (eg.
CESS+SINGLE).ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.10.1.18 |
cdx6500BSC3270RestrictConnDestAll calls originating from this port will be routed to
the destination specified in this parameter, irrespective
of route selection table entries. For example, to route
calls to port 1, use P1. To route calls to port 2,
station 4, use P2S4.
Blank this field to disable this function.ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.10.1.19 |
cdx6500bsc3270ElectricalInterfaceTypeSpecify the Electrical Interface Type:
V.24 - V.24 Electrical Interface Type
V.35 - V.35 Electrical Interface Type
V.36 - V.36 Electrical Interface Type
X.21 - X.21 Electrical Interface Type
NONE - Electrically disabledro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.20 |
cdx6500bsc3270V24ElectricalInterfaceOptionSpecify the Pin 22 option:
RI - V.24 uses Pin 22 for Ring Indicator output signal
TM - V.24 uses Pin 22 for Test Mode input signalro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.21 |
cdx6500bsc3270HighSpeedElectricalInterfaceOptionSpecify the cable type:
NONE - V.35/V.36/X.21 DCE with straight through cable
XOVER - V.35/V.36/X.21 DCE with crossover adapter cablero Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.10.1.22 |
cdx6500PCTBSC3270DeviceGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.1.4 |
cdx6500PBCTBSC3270DevTableA table of BSC3270 device configuration entries. SEQUENCE OF Cdx6500PBCTBSC3270DevEntry .1.3.6.1.4.1.449.2.1.2.1.4.1 |
cdx6500PBCTBSC3270DevEntryA BSC3270 Device Configuration Table entry. Each entry
contains the configuration parameters for a single
BSC3270 device. Cdx6500PBCTBSC3270DevEntry .1.3.6.1.4.1.449.2.1.2.1.4.1.1 |
cdx6500BSC3270DevPortNumberThe BSC3270 port accessing this device.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.4.1.1.1 |
cdx6500BSC3270DevEntryThe unique number for this specific port, 1 ... 32.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.4.1.1.2 |
cdx6500BSC3270BSCControlUnitAddrThis is the Poll address of the Control Unit that supports
this device. It consists of two hexadecimal digits. Valid
ranges depend on device Character Set as follows:
EBCDIC: 40,C1,C2,C3,C4,C5,C6,C7,C8,C9,4A,4B,4C,4D,4E,4F,
50,D1,D2,D3,D4,D5,D6,D7,D8,D9,5A,5B,5C,5D,5E,5F
ASCII : 20,41,42,43,44,45,46,47,48,49,5B,2E,3C,28,2B,21,
26,4A,4B,4C,4D,4E,4F,50,51,52,5D,24,2A,29,3B,5Ero DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.3 |
cdx6500BSC3270BSCDevAddrThis is the Poll/Select address of this device. It
consists of two hexadecimal digits. Valid ranges
depend on device Character Set as follows:
EBCDIC: 40,C1,C2,C3,C4,C5,C6,C7,C8,C9,4A,4B,4C,4D,4E,4F,
50,D1,D2,D3,D4,D5,D6,D7,D8,D9,5A,5B,5C,5D,5E,5F
ASCII : 20,41,42,43,44,45,46,47,48,49,5B,2E,3C,28,2B,21,
26,4A,4B,4C,4D,4E,4F,50,51,52,5D,24,2A,29,3B,5Ero DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.4 |
cdx6500BSC3270DSPDevTypeterm - device is a terminal.
prin - device is a printer.
newvalTerm - same functionality as 'term', new enumeration
introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.4.1.1.5 |
cdx6500BSC3270DSPControlSpecifies device call control. Values AUTO and FAST
should not be simultaneously chosen:
NONE - device will not be a call originator and will
be enabled
ORG - call originator
AUTO - if originator, automatically connect to
pre-configured host
FAST - a TPAD establishes a call to a pre-configured
host using a pre-configured function key.
Not applicable to HPAD
ACK - requires DSP acknowledgement for all messages
DISABLE - stops polling and clears X.25 calls
Any combination of above specified by summing
(eg. ORG+AUTO).ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.6 |
cdx6500BSC3270DevControlSpecifies device control parameters:
NONE - no device control parameter set.
GPOLL- disables specific polling of a device. The device
will only be polled by general polls. (TPAD only)
SPOLL- forces specific polling of a device. (TPAD only)
NSERV- no service messages will be sent to the device.
(TPAD only)
NSTAT- disables the generation of dummy DEVICE END
status message. (HPAD only)
RVI - forces TPAD to send RVI as an ACK for terminal
text/status messages terminated with ETB or ETX.
(TPAD only)
Any combination of above specified by summing
(e.g. GPOLL+NSERV).
Configuration Notes:
GPOLL overrides SPOLL if both are selected, this is not
recommended.
Devices under a COMMON CU ADDRESS must have identical
Polling methods (e.g. CU 40 has 4 devices, all devices
must be GPOLL, SPOLL or neither.)ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.7 |
cdx6500BSC3270DSPDevCharacteristicsNONE - no option
XPAR - device supports transparency
COLOR - device supports color
PRINa - printer is attached to a terminal device
Any combination of above specified by summing
(eg. COLOR+PRINa).ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.8 |
cdx6500BSC3270DSPDevFormatSizeSpecifies maximum size of the terminal or printer
message.
newvalFormat480 - same functionality as 'format480',
new enumeration introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.4.1.1.9 |
cdx6500BSC3270DSPCharSetCapabilityIndicates device capability:
NONE - no indication of capability
APL - APL capability
TEXT - Text capability
Any combination of above specified by summing
(eg. APL+TEXT).ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.10 |
cdx6500BSC3270ConnReqModeSpecifies which DSP Connection Request Mode (CRM) to use.
There are three modes of connection as follow:
1 - fixed class CRM, connects a call to the device on a
control unit with addresses that match the addresses
of the call originator.
2 - specific class CRM, connects to a specific device as
indicated in the destination control unit and device
address.
3 - non-specific class CRM, connects to any device as
indicated in the destination control unit address.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.4.1.1.11 |
cdx6500BSC3270DestControlUnitAddrSpecifies control unit address on remote PAD. Used with
Connection Request Mode = 2 or 3.ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.12 |
cdx6500BSC3270DestDevAddrSpecifies device address on remote PAD. Used with
Connection Request Mode = 2 or 3.ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.13 |
cdx6500BSC3270AutocallMnemonicThis mnemonic name is used if this device is configured
for AUTO or FAST calling.ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.4.1.1.14 |
cdx6500BSC3270DSPApplicationIdentSpecifies the target application to which this device
would be connected. This should match with the
application ID of the Host DSP device.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.4.1.1.15 |
cdx6500BSC3270DSPCompatibilitySelect yes if the device connects to a DSP host or if it
connects to a Codex 6507/6525 node with 2.13 or higher
software revision. Select no if the device connects to
6507/6525 with pre-2.13 release.
newvalNo - same functionality as 'no', new enumeration
introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.4.1.1.16 |
cdx6500BSC3270BillRecThis controls whether billing (accounting) records will
be created for calls on this Device.
newvalOff - same functionality as 'off', new enumeration
introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.4.1.1.17 |
cdx6500BSC3270TrafficPriorityThis is the traffic priority of the 3270 device; low, medium,
high, or expedite.
newvalLowPriority - same functionality as 'lowpriority',
new enumeration introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.4.1.1.18 |
cdx6500Statistics OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3 |
cdx6500StatProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3.1 |
cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3.1.1 |
cdx6500PPSTBSC3270PortTableA table of BSC3270 port statistics entries. SEQUENCE OF Cdx6500PPSTBSC3270PortEntry .1.3.6.1.4.1.449.2.1.3.1.1.10 |
cdx6500PPSTBSC3270PortEntryA BSC3270 Port Statistic Table entry. Each entry
contains the statistics for a single BSC3270 port. Cdx6500PPSTBSC3270PortEntry .1.3.6.1.4.1.449.2.1.3.1.1.10.1 |
cdx6500BSC3270StatPortNumberThe BSC3270 port number described by this entry.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.10.1.1 |
cdx6500BSC3270PortStatusPort Status indicates whether or not the port
is switched on and is ready for operation. This value
may be one of :
up - Port is up and running
down - port is down
disabled - port has been disabled
enabled - port has been enabled, but is not yet Up
busyOut - port has been set to be disabled as soon as
last active session is disestablished. No
new sessions will be established.
newvalDisabled - same functionality as 'disabled',
new enumeration introduced for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.3.1.1.10.1.2 |
cdx6500BSC3270PortStatePort State indicates what the port is actually in the
process of doing. This value may be one of :
INACTIVE - H/TPAD port inactive entered during boot
WTPOLSERVE - TPAD is waiting for response to a poll
WTSELRESP - TPAD is waiting for the response to a
select
WTDATARESP - H/TPAD is waiting for data to be
acknowledged
DATA - H/TPAD is in the process of sending/receiving
data
SEL/POL - TPAD is about to select or poll a
controller. This is the most common state
for a TPAD
SELECT - TPAD is about to select a device
POLL - TPAD is about to poll a device
WTENQRESP - H/TPAD is waiting for a NAK response to
an ENQ sent
IDLE - HPAD is waiting for the host to send commands.
This is the most common state of the HPAD
WTEOT - HPAD is waiting for an expected EOT from the
host
FLUSHINGDATA - HPAD encountered an error in the message
received from the host. As a result,
the data is being flushed
WTLCM - HPAD received a read/modify and is waiting for
the response from the TPAD.ro DisplayString .1.3.6.1.4.1.449.2.1.3.1.1.10.1.3 |
cdx6500BSC3270PortSpeedThis is the speed of the port if clock is internal. If
clock is external, this is the detected clock speed. If
Port Speed is 0, clock is external, but clocking is not
being received from attatched device.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.10.1.4 |
cdx6500BSC3270PortUtilInPertcentage of Port input bandwidth in use.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.10.1.5 |
cdx6500BSC3270PortUtilOutPertcentage of Port output bandwidth in use.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.10.1.6 |
cdx6500BSC3270InMsgsNumber of message received since last node, port, or
statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.7 |
cdx6500BSC3270OutMsgsNumber of message sent since last node, port, or
statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.8 |
cdx6500BSC3270InCharsNumber of characters received since last node, port, or
statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.9 |
cdx6500BSC3270OutCharsNumber of characters sent since last node, port, or
statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.10 |
cdx6500BSC3270CharRateInNumber of characters received per second.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.10.1.11 |
cdx6500BSC3270CharRateOutNumber of characters sent per second.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.10.1.12 |
cdx6500BSC3270CrcBccErrsNumber of CRC errors since last node, port, or
statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.13 |
cdx6500BSC3270InPosAcksNumber of ACKs received since last node, port,
or statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.14 |
cdx6500BSC3270OutPosAcksNumber of ACKs sent since last node, port,
or statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.15 |
cdx6500BSC3270InNegAcksNumber of NAKs received since last node, port,
or statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.16 |
cdx6500BSC3270OutNegAcksNumber of NAKs sent since last node, port,
or statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.17 |
cdx6500BSC3270MsgRateInNumber of messages received per second.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.18 |
cdx6500BSC3270MsgRateOutNumber of messages sent per second.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.19 |
cdx6500BSC3270InEnqNumber of ENQs received since last node, port,
or statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.20 |
cdx6500BSC3270OutEnqNumber of ENQs sent since last node, port,
or statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.21 |
cdx6500BSC3270NumRetranNumber of messages retransmitted since last node,
port, or statistics reset.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.10.1.22 |
cdx6500Controls OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.4 |