Home/Catalog/BSC2780-OPT-MIB

BSC2780-OPT-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

50
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

50 total
Object Name
codex
OBJECT IDENTIFIER
.1.3.6.1.4.1.449
RFC1155-SMI
Unknown
.1.3.6.1.4.1.449
cdxProductSpecific
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2
cdx6500
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1
cdx6500Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2
cdx6500CfgProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1
cdx6500PCTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.1
cdx6500PPCTBSC2780TableA table of BSC2780 Port configuration entries.
SEQUENCE OF Cdx6500Bsc2780PortConfigEntry
.1.3.6.1.4.1.449.2.1.2.1.1.11
cdx6500bsc2780PortConfigEntryA BSC2780 Configuration Table entry. Each entry contains the configuration parameters for a single BSC2780 port.
Cdx6500Bsc2780PortConfigEntry
.1.3.6.1.4.1.449.2.1.2.1.1.11.1
cdx6500bsc2780PortNumberThe BSC2780 port number described by this entry.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.1
cdx6500bsc2780ClockSourceint - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.2
cdx6500bsc2780ClockSpeedThis is the speed of the port in bits per second, when using internal clocking.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.3
cdx6500bsc2780ContentionIndicates whether Half Duplex (hdx) or Full Duplex (fdx) modem signals are being generated. Full Duplex indicates communication is occuring in both directions simultaneously between devices. Half Duplex indicates transmission is occuring in both directions, but only in one direction at a time. newvalHdx : same functionality as 'hdx', new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.4
cdx6500bsc2780ErrThreshCountIndicates number of consecutive errors that can occur before a device is considered down.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.5
cdx6500bsc2780DisConnOnErrorSpecifies whether a session should be disconnected if a control unit has not responded once the Error Threshold Count has been exceeded. newvalNo : same functionality as 'no',new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.6
cdx6500bsc2780ConnTypeSpecify the control signal handshake required for a connection to be made to this port: simp - simple, no control signals required v25b - port emulates a dial modem using V.25 bis mode 108/2 rs366 - port emulates data port for the 801 autodialer emri - port emulates a dial modem with ring indicator (RI) dimo - port handshakes with attached modem NODE BOOT will be required when this type is changed to/from rs366 or v25b. newvalSimp - same functionality as 'simp', new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.7
cdx6500bsc2780InterBuffTimeoutSpecifies the maximum amount of time in seconds the PAD will wait for the end of a multi-packet message from the network. If this time limit is exceeded, the PAD will abort the entire message and request retransmission.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.8
cdx6500bsc2780PortSubAddr0 - 3 Decimal digits Calls addressed to this node and with this subaddress will be routed to this port.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.9
cdx6500bsc2780ReConnRetryNumber of times connection will be reattempted after a network induced disconnect.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.10
cdx6500bsc2780AutocallMnemonicThis mnemonic name is used if this device is configured as a call originator.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.11
cdx6500bsc2780RestrictConnDestAll calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.12
cdx6500bsc2780BillRecThis controls whether billing (accounting) records will be created for calls on this port. off - billing (accounting) records will not be created. on - billing (accounting) records will be created. newvalOff - same functionality as 'off', new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.13
cdx6500bsc2780DSRfollowSVCSpecify whether DSR on/off required with circuit on/off. This is only available with connection type SIMP or RS366. yes = DSR will be ON only while a call is in place, The DTE connected to the port can not originate a call no = DSR is always ON. newvalNo : same functionality as 'no', new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.14
cdx6500bsc2780DSRholdTimeTime in steps of 50 ms to drop DSR signal after the circuit is disconnected in DSR-Follow-SVC mode. This timer value is ignored otherwise.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.15
cdx6500bsc2780PortOptionThis object has been deprecated, It is replaced by cdx6500bsc2780PortOptString.rodeprecated
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.16
cdx6500bsc2780TrafficPriorityThis is the traffic priority of the 2780 device; low, medium, high, and expedite. newvalLowPriority : same functionality as 'lowPriority', new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.17
cdx6500bsc2780PortOptStringThis is the new object for cdx6500bsc2780PortOption. Specify any of the following port control options: NONE - no option specified. EOT - EOT will be dropped when no data has been sent across network. ACK - End-to-End Acknowledgements are to be used. TID - Host/Terminal ID(0-120 characters) with initial line Bid/Response is to be exchanged. NOTTD - does not send a TTD control character. Any combination of above specified by summing(e.g. ACK+TID).ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.18
cdx6500bsc2780IdleDiscTimerThe call on the port will be cleared when this timer is expired. This timer will be started when it received an EOT. 0 - Timer Disabled. 1 to 60 - Timer Value in seconds.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.19
cdx6500bsc2780ElectricalInterfaceTypeSpecify the Electrical Interface Type: V.24 - V.24 Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabledro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.20
cdx6500bsc2780V24ElectricalInterfaceOptionSpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signalro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.21
cdx6500bsc2780HighSpeedElectricalInterfaceOptionSpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cablero
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.22
cdx6500bsc2780RemoteTypeSpecify the remote type: T2780 - remote is BSC2780 PAD SNAINT - remote is SNA/2780 Interactivero
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.11.1.23
cdx6500Statistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3
cdx6500StatProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1
cdx6500PSTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.1
cdx6500PPSTBSC2780TableA table of BSC2780 port statistics entries.
SEQUENCE OF Cdx6500Bsc2780PortStatEntry
.1.3.6.1.4.1.449.2.1.3.1.1.11
cdx6500bsc2780PortStatEntryA BSC2780 Port Statistic Table entry. Each entry contains the statistics for a single BSC2780 port.
Cdx6500Bsc2780PortStatEntry
.1.3.6.1.4.1.449.2.1.3.1.1.11.1
cdx6500bsc2780StatPortNumberThe BSC2780 port number described by this entry.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.1
cdx6500bsc2780PortStatusPort Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running. down - port is down. disabled - port has been disabled. enabled - port has been enabled, but is not yet Up. busyOut - port has been set to be disabled as soon as last active session is disestablished. No new sessions will be established. newvalDisabled - same functionality as 'disabled', new enumeration introduced for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.2
cdx6500bsc2780PortStatePort State indicates what the port is actually in the process of doing. This value may be one of : DISC - No call is currently connected to the specified port. The port is IDLE. PENACC - The specified port is waiting for a call accept. DATA - The port is busy. Data is being passed between 2780/3780 devices. PENDACK - The port has sent a message (text) or an enquiry (ENQ) and is waiting for an acknowledgement (ACK). EOT - End of transmission (EOT) is received. The port is waiting for a new line bid. DRO - Outbound Data is restrained. DRI - Inbound Data is restrained. PENDISC - The port is waiting for disconnection. The device sends an EOT perior to accepting a call. PENDNAK - The port has sent a message (text) with the bad BCC and is waiting for a negative acknowledgement (NAK). PENDEIA - The port is waiting for connecting to the attached device. PENEIADISC - The port is waiting for receiving all packets acknowledged from remote before disconnecting to the local device. WT4TIMEOUT - The port is waiting for clearing the internal buffers before dropping the EIA signals. TTD - Temporary text delay (TTD) is received. The port is waiting for sending a negative acknowledgement (NAK) to the local device. WTTDNAK - The port has sent a temporary text delay (TTD) and is waiting for a negative acknowledgement (NAK). RACK - The port has sent a message (text) to the remote and is waiting for an End-to-End acknowledgement. TID - The port is waiting for an initial enquiry (ENQ) or acknowledgement (ACK0) with the host/terminal ID from the local device. RTID - The port is waiting for an initial enquiry (ENQ) or acknowledgement (ACK0) with the host/terminal ID from the remote device.ro
DisplayString
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.3
cdx6500bsc2780PortSpeedThis is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking is not being received from attatched device.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.4
cdx6500bsc2780PortUtilInPercentage of Port input bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.5
cdx6500bsc2780PortUtilOutPercentage of Port output bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.6
cdx6500bsc2780InMsgsNumber of message received since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.7
cdx6500bsc2780OutMsgsNumber of message sent since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.8
cdx6500bsc2780InCharsNumber of characters received since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.9
cdx6500bsc2780OutCharsNumber of characters sent since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.10
cdx6500bsc2780CharRateInNumber of characters received per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.11
cdx6500bsc2780CharRateOutNumber of characters sent per second.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.12
cdx6500bsc2780CrcBccErrsNumber of CRC errors since last node, port, or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.11.1.13