BROADCOM-POWER-ETHERNET-MIB
AI MIB Summary
The BROADCOM-POWER-ETHERNET-MIB extends IETF Power over Ethernet (PoE) management capabilities to monitor and control Power Source Equipment (PSE) functions on Broadcom-based network hardware, specifically exposing vendor-specific metrics for power allocation, consumption, and fault status not covered by the standard POWER-ETHERNET-MIB.
This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet Interfaces and Hub MIB Working Group for managing Power Source Equipment (PSE). The objects in this MIB are intended to provide additional objects for reporting information available to the hardware on this platform which are not represented in the draft MIB.
Main OID:
fastPathpowerEthernetMIB.1.3.6.1.4.1.4526.10.15
24
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
24 total| Object Name |
|---|
fastPathpowerEthernetMIBThis MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
Interfaces and Hub MIB Working Group for managing Power Source
Equipment (PSE). The objects in this MIB are intended to provide
additional objects for reporting information available to the hardware
on this platform which are not represented in the draft MIB. MODULE-IDENTITY .1.3.6.1.4.1.4526.10.15 |
agentPethObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4526.10.15.1 |
agentPethPsePortTableA table of per-port information and configuration objects relating
to the power status of each port. SEQUENCE OF AgentPethPsePortEntry .1.3.6.1.4.1.4526.10.15.1.1 |
agentPethPsePortEntryA collection of objects providing additional power information
and control parameters for the specified port. AgentPethPsePortEntry .1.3.6.1.4.1.4526.10.15.1.1.1 |
agentPethPowerLimitThe configured maximum power this port can provide to an
attached device measured in Milliwatts.rw Gauge32 UNITS "Milliwatts" .1.3.6.1.4.1.4526.10.15.1.1.1.1 |
agentPethOutputPowerThe power this port is supplying to an attached device measured
in Milliwatts.ro Gauge32 UNITS "Milliwatts" .1.3.6.1.4.1.4526.10.15.1.1.1.2 |
agentPethOutputCurrentThe current this port is supplying to an attached device measured
in Milliamps.ro Gauge32 UNITS "Milliamps" .1.3.6.1.4.1.4526.10.15.1.1.1.3 |
agentPethOutputVoltsThe voltage this port is supplying to an attached device measured
in millivolts.ro Gauge32 UNITS "Millivolts" .1.3.6.1.4.1.4526.10.15.1.1.1.4 |
agentPethTemperatureThe temperature measured at this port of the PoE Controller. It is
measured in degree celcius.ro Gauge32 UNITS "DEGREES" .1.3.6.1.4.1.4526.10.15.1.1.1.5 |
agentPethPowerLimitTypeDescribes or controls the maximum power that a port can deliver
A value of dot3af(1) means that the port power limit is as per
the dot3af class of the PD attached.
A value of user(2) means that the port power limit is equal to the value
specified by agentPethPowerLimitrw Enumeration .1.3.6.1.4.1.4526.10.15.1.1.1.6 |
agentPethHighPowerEnabletrue (1) The PSE port can deliver power up to 32Watts.
false(2) The PSE port can deliver power up to 18Wattsrwobsolete TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4526.10.15.1.1.1.7 |
agentPethPowerDetectionTypeDescribes PD detection mechanism performed by the PSE port.
A value of none(0) means no detection is done.
A value of legacy(1) means only legacy capacitive detection scheme is
used.
A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme
is used.
A value of 4ptdot3afandlegacy(3)means that IEEE 802.3af 4point detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme
is used.
A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
The value 'none' can not be forcibly set by the administrator.rw Enumeration .1.3.6.1.4.1.4526.10.15.1.1.1.8 |
agentPethFaultStatusDescribes the error description when the pse port is in fault status.
A value of none(0) specifies that the pse port is not in any error state.
A value of mpsAbsent(1) specifies that the pse port has detected and absence
of main power supply.
A value of short(2) specifies that the pse port has detected a short circuit
condition.
A value of overload(3) specifies that the pd connected to the pse port had tried
to draw more power than permissible by the hardware.
A value of powerDenied(4) specifies that the pse port has been denied power
because of shortage of power or due to administrative action.ro Enumeration .1.3.6.1.4.1.4526.10.15.1.1.1.9 |
agentPethPortResetA value of reset(1) is used to move the pse port dot3af state to idle. A
read on this object will always return the value none(0). The value none(0)
can not be forcibly set by the administrtor.rw Enumeration .1.3.6.1.4.1.4526.10.15.1.1.1.10 |
agentPethPowerUpModeDescribes the power up mode used by the PSE Port.
A value of 802dot3af(0) means port is powered in IEEE 802.3af mode.
A value of high-inrush(1) means port is powered used high-inrush current,
used by legacy PD's
A value of pre-802dot3at(2) means port is powered in IEEE 802.3af mode initially,
switched to high-power IEEE 802.3at mode before 75msec. This mode needs
to be used if PSE is NOT performing Layer 2 Classification Or
PSE is performing 2-Event Layer 1 Classification.
A value of 802dot3at(3) means is port is powered in IEEE 802.3at mode. i.e. if class detected
by PSE is not class4 then PSE port will not power up the PD.rw Enumeration .1.3.6.1.4.1.4526.10.15.1.1.1.11 |
agentPethClassificationModeDescribes the classification mode used by the PSE Port.
A value of bypass(0) means port is not performing classification.
A value of standard(1) means port is performing classification as per IEEE 802.3af/802.3at .rw Enumeration .1.3.6.1.4.1.4526.10.15.1.1.1.12 |
agentPethMainPseObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4526.10.15.1.2 |
agentPethMainPseTableA table of objects that display and control attributes
of the main power source in a PSE device. Ethernet
switches are one example of boxes that would support
these objects.
Values of all read-write objects in this table are
persistent at restart/reboot. SEQUENCE OF AgentPethMainPseEntry .1.3.6.1.4.1.4526.10.15.1.2.1 |
agentPethMainPseEntryA set of objects that display and control the Main
power of a PSE. AgentPethMainPseEntry .1.3.6.1.4.1.4526.10.15.1.2.1.1 |
agentPethMainPseLegacyEnable/Disable Legacy device detection. The
value true(1) means legacy devices are detected; the
value false(2) means legacy devices are not detected.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4526.10.15.1.2.1.1.1 |
agentPethPseTableA table of per-unit information and configuration objects relating
to the power configurtion for the entire pse unit. SEQUENCE OF AgentPethPseEntry .1.3.6.1.4.1.4526.10.15.1.3 |
agentPethPseEntryA collection of objects providing additional power information
and control parameters for the specified pse unit. AgentPethPseEntry .1.3.6.1.4.1.4526.10.15.1.3.1 |
agentPethPsePowerManagementModeDescribes or controls the power management algorithm used by the pse
to deliver power to the requesting PDsthat a pds.rw Enumeration .1.3.6.1.4.1.4526.10.15.1.3.1.1 |
agentPethPseAutoResetEnabletrue (1) The PSE port is reset with out administrator intervention whenver a
fault condition occurs.
false(2) Administrator has to reset the pse port whenver a fault condition
is detected.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4526.10.15.1.3.1.2 |