AI MIB Summary
The ADH3-NETCOM-MIB module defines the management interface for Environmental Technology Inc. SNMP devices, enabling the monitoring of environmental telemetry and system status metrics such as temperature, humidity, voltage, and fan speeds.
The Structure of Management Information for Environmental Technology Inc. SNMP devices
Main OID:
environmentalTechnology.1.3.6.1.4.1.32185
16
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
16 total| Object Name |
|---|
environmentalTechnologyThe Structure of Management Information for Environmental Technology Inc. SNMP devices MODULE-IDENTITY .1.3.6.1.4.1.32185 |
netcomADH-3 NETCOM OBJECT IDENTIFIER .1.3.6.1.4.1.32185.2 |
statusInfo OBJECT IDENTIFIER .1.3.6.1.4.1.32185.2.1 |
allStatusesSummary: same as objects 2-7, separated by semicolonsro DisplayString .1.3.6.1.4.1.32185.2.1.1 |
pressurePSIPressure, in PSIro DisplayString .1.3.6.1.4.1.32185.2.1.2 |
dutycycleCurrent duty cycle, in percent; --- if none availablero DisplayString .1.3.6.1.4.1.32185.2.1.3 |
statusVarsSummary of the status of the unit. Is always 6 characters Character 1 is major state: N=normal, S=standby, L=leaky Character 2 is environment: N=normal, C=cold, H=hot Character 3 is canister 1 condition: O=OK (ie dry), F=full (wet), U=unknown, D=dead Character 4 is canister 1 usage: I=idle, U=in use, R=regenerating Character 5 is canister 2 condition, as in character 3 Character 5 is canister 2 usage, as in character 4ro DisplayString .1.3.6.1.4.1.32185.2.1.4 |
temperatureCurrent temperature, in degrees Fro DisplayString .1.3.6.1.4.1.32185.2.1.5 |
alarmsCurrent alarm conditions: is a list of them Each character has a - for no alarm, or an A or W if there is an alarm. A means alarm (serious), W means a warning (not so serious).ro DisplayString .1.3.6.1.4.1.32185.2.1.6 |
compressorHoursNumber of hours that the compressor has been running; resolution is tenths of an hour.ro DisplayString .1.3.6.1.4.1.32185.2.1.7 |
majorStateMajor state of the dehydrator. Online: currently pressurizing. Standby: not pressurizing. Leaky: shut down because of inability to pressurize.rw Enumeration .1.3.6.1.4.1.32185.2.1.8 |
paramsInfo OBJECT IDENTIFIER .1.3.6.1.4.1.32185.2.2 |
lowerLimitThe pressure, in PSI, at which the unit starts to pumpro DisplayString .1.3.6.1.4.1.32185.2.2.1 |
upperLimitThe pressure, in PSI, which the unit pressurizes toro DisplayString .1.3.6.1.4.1.32185.2.2.2 |
lowerAlarmLimitThe pressure, in PSI, below which the unit declares a low pressure alarmro DisplayString .1.3.6.1.4.1.32185.2.2.3 |
upperAlarmLimitThe pressure, in PSI, above which the unit declares a high pressure alarmro DisplayString .1.3.6.1.4.1.32185.2.2.4 |