ACD-VSET-MIB

AI MIB Summary

The ACD-VSET-MIB module enables Accedian Networks devices to expose and manage VLAN set configurations via SNMP, specifically tracking the association of VLAN identifiers with network interfaces or logical groups for traffic segmentation and policy enforcement.

The VLAN sets database for this Accedian Networks device.
Main OID:
acdVSet.1.3.6.1.4.1.22420.2.13
20
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

20 total
Object Name
acdVSetThe VLAN sets database for this Accedian Networks device.
MODULE-IDENTITY
.1.3.6.1.4.1.22420.2.13
acdVSetNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.22420.2.13.0
acdVSetMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.22420.2.13.1
acdVSetConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.22420.2.13.1.1
acdVSetConfigTableTable of all VID set.
SEQUENCE OF AcdVSetConfigEntry
.1.3.6.1.4.1.22420.2.13.1.1.1
acdVSetConfigEntryAn entry consisting of all settings to a VLAN set.
AcdVSetConfigEntry
.1.3.6.1.4.1.22420.2.13.1.1.1.1
acdVSetConfigPolicyListIDThis object identifies for which Policy list of this VLAN set.
Unsigned32
.1.3.6.1.4.1.22420.2.13.1.1.1.1.1
acdVSetConfigIDUnique value for each VLAN set instance.
Unsigned32
.1.3.6.1.4.1.22420.2.13.1.1.1.1.2
acdVSetConfigRowStatusAll columns must have a valid value before a row can be activated. To create a new VLAN set you shall provide the a unique name, the type and policy list id for an empty row with the RowStatus set to Create and Go. To delete the VLAN set you need to set the RowStatus to destroy.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.22420.2.13.1.1.1.1.3
acdVSetConfigNameThis is a string to uniquely identify the VLAN set.rw
DisplayString
.1.3.6.1.4.1.22420.2.13.1.1.1.1.4
acdVSetConfigVlanTypeVLAN Ethernet type.rw
AcdVsetVlanType
.1.3.6.1.4.1.22420.2.13.1.1.1.1.5
acdVSetConfigVlanIDs0to1023Each octet specifies a set of eight VLANs, the first octet specifying VLAN ID 0 through 7, and so on. Within each octet, the most significant bit represents the lowest numbered VLAN ID. If that bit has a value of '1' then that VLAN is included in the set of VLANs; the VLAN is not included otherwise.rw
OCTET STRING
.1.3.6.1.4.1.22420.2.13.1.1.1.1.6
acdVSetConfigVlanIDs1024to2047Each octet specifies a set of eight VLANs, the first octet specifying VLAN ID 1024 through 1031, and so on. Within each octet, the most significant bit represents the lowest numbered VLAN ID. If that bit has a value of '1' then that VLAN is included in the set of VLANs; the VLAN is not included otherwise.rw
OCTET STRING
.1.3.6.1.4.1.22420.2.13.1.1.1.1.7
acdVSetConfigVlanIDs2048to3071Each octet specifies a set of eight VLANs, the first octet specifying VLAN ID 2048 through 2055, and so on. Within each octet, the most significant bit represents the lowest numbered VLAN ID. If that bit has a value of '1' then that VLAN is included in the set of VLANs; the VLAN is not included otherwise.rw
OCTET STRING
.1.3.6.1.4.1.22420.2.13.1.1.1.1.8
acdVSetConfigVlanIDs3072to4095Each octet specifies a set of eight VLANs, the first octet specifying VLAN ID 3072 through 3079, and so on. Within each octet, the most significant bit represents the lowest numbered VLAN ID. If that bit has a value of '1' then that VLAN is included in the set of VLANs; the VLAN is not included otherwise.rw
OCTET STRING
.1.3.6.1.4.1.22420.2.13.1.1.1.1.9
acdVSetConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.22420.2.13.2
acdVSetCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.22420.2.13.2.1
acdVSetComplianceThe compliance statement for support of the ACD-VSET-MIB module.
Unknown
.1.3.6.1.4.1.22420.2.13.2.1.1
acdVSetGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.22420.2.13.2.2
acdVSetConfigGroupObjects for the VLAN set configuration Group.
Unknown
.1.3.6.1.4.1.22420.2.13.2.2.1

More MIBs from Accedian

Browse all AccedianMIBs →
ACD-CFM-MIB

The ACD-CFM-MIB module enables the monitoring and configuration of IEEE 802.1ag Connectivity Fault Management (CFM) sessions to measure network latency and track packet loss statistics. It provides specific MIB objects for retrieving delay measurement results and configuring packet loss thresholds within Ethernet service provider networks.

329 objects→
ACD-PAA-MIB

The ACD-PAA-MIB module enables Accedian Networks devices to expose and manage the Performance Analysis Agent (PAA) database, facilitating the retrieval of granular network performance metrics such as latency, jitter, packet loss, and path quality statistics for active flow monitoring.

301 objects→
ACD-TWAMP-GEN-MIB

The ACD-TWAMP-GEN-MIB provides management access to the TWAMP Generator database on Accedian Networks devices, enabling the monitoring of active measurement sessions, configuration parameters, and performance metrics for Two-Way Active Measurement Protocol (TWAMP) traffic generation.

177 objects→
ACD-FILTER-MIB

The ACD-FILTER-MIB manages the configuration and state of packet filtering rules within Accedian Networks performance monitoring appliances, enabling administrators to define traffic selection criteria for precise network path analysis. This module specifically exposes the filter database structure, allowing for the enforcement of specific packet capture filters to isolate relevant traffic flows for latency and jitter measurement.

175 objects→
ACD-PORT-MIB

The ACD-PORT-MIB module enables monitoring of interface-level traffic counters and performance metrics on Accedian Networks devices, specifically facilitating the collection of port statistics for network latency and throughput analysis.

112 objects→
ACD-ERP-MIB

The ACD-ERP-MIB module provides access to the Accedian Networks device's Enterprise Resource Planning database, exposing performance metrics and operational data required for end-to-end network path analysis and service level monitoring. This MIB enables the retrieval of specific ERP state variables and counters to validate network performance against defined service level agreements.

111 objects→