ACD-ALARM-MIB
The ACD-ALARM-MIB module enables Accedian Networks devices to expose and manage alarm state tables via SNMP, providing real-time visibility into device health events, interface errors, and system faults. This MIB facilitates automated fault detection and alerting by mapping specific hardware and software anomalies to standardized alarm entries for network operations monitoring.
Imported Objects
Objects
43 total| Object Name |
|---|
acdAlarmThe alarm Table for this Accedian Networks device. MODULE-IDENTITY .1.3.6.1.4.1.22420.2.1 |
acdAlarmGenThreshOnThis value represents the Alarm On Hysteris. This is the time since the detection of the On event inside the system versus the report. This is to avoid storm of notifications.rw Unsigned32 .1.3.6.1.4.1.22420.2.1.1 |
acdAlarmGenThreshOffThis value represents the Alarm Off Hysteris. This is the time since the detection of the Off event inside the system versus the report. This is to avoid storm of notifications.rw Unsigned32 .1.3.6.1.4.1.22420.2.1.2 |
acdAlarmGenLedEnableThis is to Enable the alarms reporting through the LEDs.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.3 |
acdAlarmGenSyslogEnableThis is to Enable the alarms reporting through the syslog system.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.4 |
acdAlarmGenSNMPEnableThis is to Enable the alarms reporting through the SNMP agent.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.5 |
acdAlarmGen8023AHEnableThis is to Enable the alarms reporting through the 802.3AH protocol.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.6 |
acdAlarmCfgTableTable of all alarms. SEQUENCE OF AcdAlarmCfgEntry .1.3.6.1.4.1.22420.2.1.10 |
acdAlarmCfgEntryAn alarm is an exceptional event that requires user notificaton. AcdAlarmCfgEntry .1.3.6.1.4.1.22420.2.1.10.1 |
acdAlarmCfgIDUnique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes).ro Unsigned32 .1.3.6.1.4.1.22420.2.1.10.1.1 |
acdAlarmCfgNumberUnique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.BBB.CC and is expressed in decimal, A is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.ro Unsigned32 .1.3.6.1.4.1.22420.2.1.10.1.2 |
acdAlarmCfgDescThis string is to describe the alarm in a readable way, e.g.: +5Vdc Power supply fail.rw DisplayString .1.3.6.1.4.1.22420.2.1.10.1.3 |
acdAlarmCfgEnableThis is to indicate if the alarm is reported or not.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.10.1.4 |
acdAlarmCfgSeverityAccedian Networks classifies alarms into four severity types. These types and their associated decimal codes are, informational(0), minor(1), major(2) and critical(3).rw Enumeration .1.3.6.1.4.1.22420.2.1.10.1.5 |
acdAlarmCfgServiceAffectingThis is to indicate if the alarm is service affecting or not. This value depends on the utilization of the box. For instance in an application where the monitoring of the traffic is mandatory the link down event on the monitor port is service affecting.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.10.1.6 |
acdAlarmCfgExtNumberUnique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.B.C and is expressed in decimal, A is the module number, B is the instance number and C is the error number. A module number is assigned for each source of alarm in the system (see Accedian documentation for more detail).ro DisplayString .1.3.6.1.4.1.22420.2.1.10.1.7 |
acdAlarmCfgConditionTypeThis is the type of alarm condition.ro DisplayString .1.3.6.1.4.1.22420.2.1.10.1.8 |
acdAlarmCfgAMOTypeThis is the Alarm Maintenance Object.ro DisplayString .1.3.6.1.4.1.22420.2.1.10.1.9 |
acdAlarmStatusTableTable of all alarms SEQUENCE OF AcdAlarmStatusEntry .1.3.6.1.4.1.22420.2.1.11 |
acdAlarmStatusEntryAn alarm is an exceptional event that requires user notificaton. AcdAlarmStatusEntry .1.3.6.1.4.1.22420.2.1.11.1 |
acdAlarmStatusIDUnique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes).ro Unsigned32 .1.3.6.1.4.1.22420.2.1.11.1.1 |
acdAlarmStatusNumberUnique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.ro Unsigned32 .1.3.6.1.4.1.22420.2.1.11.1.2 |
acdAlarmStatusOnThis is to indicate if the alarm is On or Off.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.11.1.3 |
acdAlarmStatusLastChangeThis is the time of the last change for this alarm. A value of zero means that nothing happened to this alarm since the last reboot.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.22420.2.1.11.1.4 |
acdAlarmStatusMsgThis string is to add information why the alarm is reported.ro DisplayString .1.3.6.1.4.1.22420.2.1.11.1.5 |
acdAlarmV2 OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.12 |
acdAlarmActiveStateThe SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps. NOTIFICATION-TYPE .1.3.6.1.4.1.22420.2.1.12.1 |
acdAlarmClearStateThe SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps. NOTIFICATION-TYPE .1.3.6.1.4.1.22420.2.1.12.2 |
acdAlarmMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.15 |
acdAlarmConfig OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.15.1 |
acdAlarmStatus OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.15.2 |
acdAlarmConformance OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.15.3 |
acdAlarmCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.15.3.1 |
acdAlarmComplianceThe compliance statement for support of the ACD-ALARM-MIB module. Unknown .1.3.6.1.4.1.22420.2.1.15.3.1.1 |
acdAlarmGroups OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.15.3.2 |
acdAlarmGenGroup. Unknown .1.3.6.1.4.1.22420.2.1.15.3.2.1 |
acdAlarmCfgGroup. Unknown .1.3.6.1.4.1.22420.2.1.15.3.2.2 |
acdAlarmStatusGroup. Unknown .1.3.6.1.4.1.22420.2.1.15.3.2.3 |
acdAlarmNotificationsGroupObjects for the Notifications group. Unknown .1.3.6.1.4.1.22420.2.1.15.3.2.4 |
acdAlarmTidGroupList of scalars to monitior changes in tables. Unknown .1.3.6.1.4.1.22420.2.1.15.3.2.5 |
acdAlarmTableTid OBJECT IDENTIFIER .1.3.6.1.4.1.22420.2.1.15.4 |
acdAlarmCfgTableLastChangeTidThis is the transaction ID of the last change of the acdAlarmCfgTable table. If this value is different since the last read this is indicate a table change.ro Unsigned32 .1.3.6.1.4.1.22420.2.1.15.4.1 |
acdAlarmStatusTableLastChangeTidThis is the transaction ID of the last change of the acdAlarmStatusTable table. If this value is different since the last read this is indicate a table change.ro Unsigned32 .1.3.6.1.4.1.22420.2.1.15.4.2 |
More MIBs from Accedian
Browse all AccedianMIBs →The ACD-CFM-MIB module enables the monitoring and configuration of IEEE 802.1ag Connectivity Fault Management (CFM) sessions to measure network latency and track packet loss statistics. It provides specific MIB objects for retrieving delay measurement results and configuring packet loss thresholds within Ethernet service provider networks.
The ACD-PAA-MIB module enables Accedian Networks devices to expose and manage the Performance Analysis Agent (PAA) database, facilitating the retrieval of granular network performance metrics such as latency, jitter, packet loss, and path quality statistics for active flow monitoring.
The ACD-TWAMP-GEN-MIB provides management access to the TWAMP Generator database on Accedian Networks devices, enabling the monitoring of active measurement sessions, configuration parameters, and performance metrics for Two-Way Active Measurement Protocol (TWAMP) traffic generation.
The ACD-FILTER-MIB manages the configuration and state of packet filtering rules within Accedian Networks performance monitoring appliances, enabling administrators to define traffic selection criteria for precise network path analysis. This module specifically exposes the filter database structure, allowing for the enforcement of specific packet capture filters to isolate relevant traffic flows for latency and jitter measurement.
The ACD-PORT-MIB module enables monitoring of interface-level traffic counters and performance metrics on Accedian Networks devices, specifically facilitating the collection of port statistics for network latency and throughput analysis.
The ACD-ERP-MIB module provides access to the Accedian Networks device's Enterprise Resource Planning database, exposing performance metrics and operational data required for end-to-end network path analysis and service level monitoring. This MIB enables the retrieval of specific ERP state variables and counters to validate network performance against defined service level agreements.