Home/Catalog/ACC-SLOT

ACC-SLOT

AI MIB Summary

Standard SNMP MIB module defining data structures for ACC-SLOT.

97
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

97 total
Object Name
accSlot
OBJECT IDENTIFIER
.1.3.6.1.4.1.5.1.1.5
IMPORTS
Unknown
.1.3.6.1.4.1.5.1.1.5
accSlotTableA list of physical port entries. The number of entries is given by the value of accSlotNum.
SEQUENCE OF AccSlotEntry
.1.3.6.1.4.1.5.1.1.5.2
accSlotEntryA table entry providing information about a specific physical port.
AccSlotEntry
.1.3.6.1.4.1.5.1.1.5.2.1
accSlotInPktsNumber of packets received on this physical interface.ro
Counter
.1.3.6.1.4.1.5.1.1.5.2.1.11
accSlotOutPktsNumber of packets transmitted on this physical interface.ro
Counter
.1.3.6.1.4.1.5.1.1.5.2.1.17
accSlotNumChangesNumber of times that this interface has changed state (either up-to-down or down-to-up).ro
Counter
.1.3.6.1.4.1.5.1.1.5.2.1.21
accSlotProtocolProtocol used on this slot. note that these enumerated values match those in accBrPortProtocol.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.22
accSlotClockModeClock mode of this portrw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.23
accSlotQueueModeQueuing mode for this slot Fair queuing provides per-conversation bandwidth allocation, with additional bandwidth allocated to higher priority traffic. Precedence queueing gives first-in-first-out service amongst priority queues.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.24
accSlotDialProcedureDial Procedure.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.25
accSlotResyncModeEstablishes operational mode of the Resync function for crypto gear. When active, a link-down condition intitiates resynchronization, which is manifested by setting the DTR (RTS) signal active (low) for 10 milliseconds.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.26
accSlotCompressModeEstablishes operational mode of Data Compression. This functionality is appropriate for serial lines.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.27
accSlotCompressV42bisP1Number of codewordsro
INTEGER
.1.3.6.1.4.1.5.1.1.5.2.1.29
accSlotCompressV42bisP2Maximum string sizero
INTEGER
.1.3.6.1.4.1.5.1.1.5.2.1.30
accSlotCompressDcs221P1Compression Moderw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.31
accSlotSevereCongPctPercent Congestedrw
INTEGER
.1.3.6.1.4.1.5.1.1.5.2.1.32
accSlotDialAddressDial Address.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5.1.1.5.2.1.33
accSlotCompressRevisionIndicates which data compression algorithm should be used for this physical port. If the confi gured protocol is Frame Relay, X.25 or PPP, the com pression mode must be new. If the configured protocol is LAPB, OLD indicates that the neighbor is running a release which predates 7.2 and the old compression algorithm should be used.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.34
accSlotCompressMaxStreamsThe maximum number of independent data streams for this physical port. This object determines the size of the history buffer pool.rw
INTEGER
.1.3.6.1.4.1.5.1.1.5.2.1.35
accSlotCompressMessageLevel.rw
INTEGER
.1.3.6.1.4.1.5.1.1.5.2.1.36
accSlotIfType.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.37
accSlotE1FrameMode.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.2.1.38
accSlotLastChangeY2KTime when a state change was last detected on this physical port. The seven byte long octet string represents year 2000 compliant date and time, and is laid out in the following structured format: 2 Byte unsigned short value of year 1 Byte value of month 1 Byte value of day of the month 1 Byte value of hour 1 Byte value of minutes 1 Byte value of secondsro
OCTET STRING
.1.3.6.1.4.1.5.1.1.5.2.1.39
accCardSlotTableA table providing objects for each installed card in the system chassis slots.
SEQUENCE OF AccCardSlotEntry
.1.3.6.1.4.1.5.1.1.5.3
accCardSlotEntryContains a summary of objects for a slot entry.
AccCardSlotEntry
.1.3.6.1.4.1.5.1.1.5.3.1
accCardSlotNumAn integer that uniquely identifies the card slot within the system chassis.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.3.1.1
accCardSlotTypeAn integer value which uniquely identifies the card type.ro
Enumeration
.1.3.6.1.4.1.5.1.1.5.3.1.2
accCardSlotRevNumA printable ASCII string representing the card rev number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5.1.1.5.3.1.3
accCardSlotSerNumA printable ASCII string representing the card serial num.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5.1.1.5.3.1.4
accCardSlotPortCnfA printable ASCII string representing the interface configuration on this slot.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5.1.1.5.3.1.5
accCardSlotAdminStateAn integer value which uniquely identifies the card administration state.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.3.1.6
accCardSlotOperStateAn integer value which uniquely identifies the card operational state.rw
Enumeration
.1.3.6.1.4.1.5.1.1.5.3.1.7
accCardSlotIndexThe ifIndex for this slot.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.3.1.8
accCardSlotNum11SlotAn integer that uniquely identifies the card slot within the 11-Slot system chassis. This can be used as an alternate index into accCardSlotTable.ro
Enumeration
.1.3.6.1.4.1.5.1.1.5.3.1.9
accCardInterfaceTableA table providing interface information for each interface on the system indicating how they relate to system slots.
SEQUENCE OF AccCardInterfaceEntry
.1.3.6.1.4.1.5.1.1.5.4
accCardInterfaceEntryContains a summary of objects for an interface entry.
AccCardInterfaceEntry
.1.3.6.1.4.1.5.1.1.5.4.1
accCardInterfaceNumAn integer that uniquely identifies the interface within the slot card.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.4.1.1
accCardInterfaceTypeThe interface type - need to define enumerations here !!ro
Enumeration
.1.3.6.1.4.1.5.1.1.5.4.1.2
accCardInterfaceSlotNumThe slot number that this interface resides on - corresponds to accCardSlotNum.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.4.1.3
accCardInterfaceIndexThe ifIndex for this interface.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.4.1.4
accCardCircuitTableA table providing information for each circuit installed in the system chassis, indicating how they relate to slots and interfaces.
SEQUENCE OF AccCardCircuitEntry
.1.3.6.1.4.1.5.1.1.5.5
accCardCircuitEntryContains a summary of objects for a circuit entry.
AccCardCircuitEntry
.1.3.6.1.4.1.5.1.1.5.5.1
accCardCircuitNumAn integer that uniquely identifies the circuit within the interface.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.5.1.1
accCardCircuitSlotNumThe slot number that this circuit resides on - corresponds to accCardSlotNum.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.5.1.2
accCardCircuitInterfaceNumThe interface number that this circuit resides on - corresponds to accCardInterfaceNum.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.5.1.3
accCardCircuitIndexThe ifIndex for this circuit.ro
INTEGER
.1.3.6.1.4.1.5.1.1.5.5.1.4
accCardSlotTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.5.1.1.5.6
accRmReqResetTrapThis trap is generated when a particular command which is a part of feature that is set to ON from OFF using the EME feature indicating that a reload can actually bring that feature effective. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.1
accRmFeatureTrapThis trap is generated when a particular command which is a part of feature that is set to OFF using the EME feature. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.2
accRmCardRemovedTrapThis indicates that a Card has been removed and tried to acticvate or deactivate the respective card SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.3
accRmActvComplTrapWhen the command to activate a card is issued. This trap indicates the activation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.4
accRmActvStartTrapWhen the command to activate card is issued. This trap indicates the activation has started SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.5
accRmActvFailTrapWhen the command (set slot state) to activate card is issued. This trap is generated in case of a failure or Mismatch of the slot. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.6
accRmDeActvStartTrapWhen the command (set slot state) to deactivate card is issued. This trap indicates the deactivation has started. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.7
accRmDeActvComplTrapWhen the command (set slot state) to deactivate a card is issued. This trap indicates the deactivation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.8
accRmCardRemvdTrapThis indicates that a Card has been removed after deactivating the slot using the set slot state command SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.9
accRmInvStateTrapIf the card is BUSY and cannot be deactivated this trap is generated SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.10
accRmFaultHndlTrapFault Hndl, Invalid State SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.11
accRmFaultIndTrapFault Indication (reason), Slot SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.12
accRmDataCallTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.13
accRmDataEnableTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the initiate data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.14
accRmDataCallAccptTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.15
accRmDataSwitchTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.16
accRmFrmWareLoadAbortTrapThis is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.17
accRmBfrAllocTrapThis is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.18
accRmLoadAbortTrapIf the file is corrupted the loading is aborted and is indicated by this trap. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 253
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.19
accRmFrmwrCompatiblTrapIf the extension is not supported by the version of the apl file then this trap is sent. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 48
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.20
accRmLoadTrap5This is basically a revision mismatch. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.21
accRmSwUpGradeMsgTrapTHIS ROUTER WILL NOT OPERATE WITH FULL FUNCTIONALITY UNTIL A VALID KEY HAS BEEN ENTERED SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.22
accRmInSuffRAMTrapThis is a memory related trap indicating that sufficient RAM is not on the borad, so that the admin can take the appropriate action of increasing the memory or replacing the memory. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.23
accRmPwrSplyMalfnTrapThis is a TIGRIS Power supply trap indicating that the one of the Power Supply is not OK and should be replaced. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.24
accRmPwrSplyStatTrapWhen one of the DUAL TIGRIS Power supply is removed or inserted this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.25
accRmFanStatTrapIf the fan in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.26
accRmDcStatTrapIf the AC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.27
accRmAcStatTrapIf the DC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.28
accRmPwr1PresTrapIf the power supply is removed or installed this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.29
accRmPwrFan1TrapIf the Tigris power supply fan fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.30
accRmPwrDc1TrapIf the Tigris power supply DC Component fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.31
accRmPwrAc1TrapIf the Tigris power supply AC Component fails or recovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.32
accRmEalm2TrapTrap indicating the external 2nd alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.33
accRmEalm1TrapTrap indicating the external 1st alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.34
accRmChasFanPresTrapTrap indicating the status of the chasis fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.35
accRmChasFanIndTrapTrap indicating the status of the chasis fan whether it failed or recovered. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.36
accRmLowMemTrapThis indicates very clearly that the Memory is very low and the admin has to do some dagnostics and take a quick action on the various memory critical issues for instance like trap log size etc., SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.37
accRmLanDiagsTrapWhen the diagnostics on the particular LAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 6
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.38
accRmWanDiagsTrapWhen the diagnostics on the particular WAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 6
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.39
accRmCardDiagsTrapWhen the diagnostics on the particular CARD slot fails this trap is generated. Indicating that there is some problem with that CARD. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 6
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.40
accRmResetTrapThis trap is to prompt the admin to reset the router as he would have changed some settings and they will be effective only after a reset for example change/deletion in static routing entry on a particular interface. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.41
accRmIdbTrapSEVERITY-DEFAULT: Indeterminate EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.42
accRmLdngElemManTrapBrowser loading Element Manager at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.43
accRmInterFileJavaManTrapIntermediate file sent to Java Manager %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.44
accRmBrowLdngSetupWizTrapBrowser loading Java Setup Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.45
accRmConfWizLddTrapConfiguration Wizard is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.46
accRmPriConfScrTrapPrimary config script sent to Configuration Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.47
accRmInstAccAppLddTrapInstant Access applet is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7
TRAP-TYPE
.1.3.6.1.4.1.5.1.1.5.6.0.48
accCardSlotTrapMsgEnterprise Trap Message for CardSlotro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5.1.1.5.6.1
ACC-SLOT - SNMP MIB Reference | MIBs Explorer