XYLO-WAN-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for XYLO-WAN-MIB.
401
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
401 total| Object Name |
|---|
anxt1TotalThe total number of T1/PRI lines on this Annex.ro INTEGER .1.3.6.1.4.1.15.2.11.1 |
anxt1ConfigT1TableTable of T1 configuration parameters that
are not included in the DS1 MIB. SEQUENCE OF Anxt1ConfigT1Entry .1.3.6.1.4.1.15.2.11.2 |
anxt1ConfigT1EntryThe internal T1 engine parameters. Anxt1ConfigT1Entry .1.3.6.1.4.1.15.2.11.2.1 |
anxt1LineIndexThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).ro INTEGER .1.3.6.1.4.1.15.2.11.2.1.1 |
anxt1AlarmSyslogIf this object is set to yes(1), all
alarm events, red, yellow and blue, are
syslogged. In other words, the detection
of any one of the alarm events will
generate a syslog provided syslogs are
enabled. The default is yes(1).
Note:
1. The syslog is generated at warning level. That
means that anxSysLogMask should be atleast at Warning
level.
2. This object is supported for T1 modules only.
Corresponding na/admin parameter would be alarmsyslog.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.11.2.1.2 |
anxt1DiiLineCodeThis object selects the line code format
used on the T1 Drop and Insert Interface.
tni_line_coding is the na/admin corresponding
parameter. This object is supported for T1 modules only.
Note: For modules configured for PRI,
b8zs is the only valid option.
ami is valid only for channelized E1rwdeprecated Enumeration .1.3.6.1.4.1.15.2.11.2.1.3 |
anxt1DiiFramingThis object controls the super frame format
used on the T1 Drop and Insert Interface.
tdi_framing is the na/admin corresp. parameter.
This object is supported for T1 modules only.
Note: For modules configured for PRI,
esf(1) is the only valid option.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.11.2.1.4 |
anxt1DiiDistanceThe distance measured in feet of the cable
run to the equipment attached to the Drop
and Insert Interface. The default is 0.
tdi_distance is the corresp. na/admin parameter.
This object is supported for T1 modules only.rwdeprecated INTEGER .1.3.6.1.4.1.15.2.11.2.1.5 |
anxt1Ds1LineBuildoutAt instalation time, the telephone company
will supply a measured cable loss measurement
between the last line generator and the
customer location. This value, named line
buildout, is measured in db and may range
from 0 and 22.5 dbs.
tni_line_buildout is the corresp. na/admin parameter.
This object is supported for T1 modules only.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.6 |
anxt1Ds1OnesDensityThis object allows the user to defeat
the ones density monitor.
The default is off but it should be
set to on when using the AMI line coding.
tni_ones_density would be corresp. na/admin parameter.
This object is supported for T1 modules only.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.11.2.1.7 |
anxt1EngineBypasswhen this object is set to yes the T1 engine
is taken out of the network. The Network
Interface is then physically coupled to
the Drop and Insert Interface, and the T1
engine has no effect on the T1 circuit.
bypass is the corresp. na/admin paramter.
This object is supported for T1 modules only.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.11.2.1.8 |
anxt1UnitIdThis is a string indicating the firmware
version for the T1/PRI engine.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.11.2.1.9 |
anxt1UnitSerialNumberThis is the 4 digit T1 engine serial number.
This object is supported for T1 modules only.rodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.11.2.1.10 |
anxt1UpTimeIndicates the up time in minutes for the T1 engine.
Doing a hard reset will reset this value.
Note: This value may not be same as sysupTime if a
hard reset has been done at any time after the annex
is brought up.
This object is supported for T1 modules only.rodeprecated INTEGER .1.3.6.1.4.1.15.2.11.2.1.11 |
anxt1InfoThis objct specifies installation information
from the telephone company regarding the T1 line.
Corresponding na/admin parameter is t1_info.
This object is supported for T1 modules only.rwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.11.2.1.12 |
anxt1TotChanThe number of internal DS0 channels on this WAN interface.ro INTEGER .1.3.6.1.4.1.15.2.11.2.1.13 |
anxt1ResetPRISetting this object to enable will reset the PRI
line. Setting the object to disable(2) will
disable the PRI line and make it unavailable.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.14 |
anxt1SwitchTypeSelect the switch type compatibile with the
PRI service provider.
default(1) Will select the default switch chosen by the wan
manager based on the moduletype. If you set the
switchtype to default(1), reboot the box, and do an
snmpget on the switchtype, you can determine which
switchtype was chosen by the wan manager.
other(2) - For a GET, this value reflects the switch
type set through Cli/Admin which does not
match with other switches listed here.
For a SET the SNMP agent will ignore it
and will not change the current switch type
set through Cli/Admin.
switch-type description protocol
sng(3), Singapore E1 ISDN PRI
ni2(4), NI-2 (National ISDN 2) T1 ISDN PRI
dms(5), DMS-100 (Northern Telecom) T1 ISDN PRI
at9(6), 5ESS (AT&T 5ESS) T1 ISDN PRI
ets(7), ETSI E1 ISDN PRI
au1(8), Australia/AUSTEL E1 PRI PRI
ntt(10), Japan NTT PRI
ets-ncrc4(11), ETSI E1 ISDN w/o CRC4 PRI
ust1(12), US/North American Channelized T1 CAS
hkt1(13), Hong Kong Channelized T1 CAS
twt1r1(14), Taiwan T1/R1 CAS
bbe1r2(15), BlueBook/CCITT E1/R2 CAS
at4(16), 4ESS (AT&T 4ESS) T1 ISDN PRI
bre1r2(17), Brazil E1/R2 CAS
kre1r2-1(18), Korea E1/R2 CAS
swe1p7(19) Sweden E1 P7 CAS
ine1r2(20), Indonesia E1/R2 CAS
cne1r2(21), China E1/R2 CAS
nze1r2(22), New Zealand E1/R2 CAS
ust1fd(23), Unites States CAS
ess-v10(24),
nosig(25), SS7, No signaling required SS7
br2e1r2(26), Brazil E1/R2, 1 second wink CAS
kre1r2-2(27), Korea E1/R2 CAS
ide1r2(28), Indonesia CAS
phe1r2(29), Philippines CAS
the1r2(30), Thailand CAS
mye1r2(31), Malaysia CAS
are1r2(32), Argentina CAS
mxe1r2(33), Mexico CAS
ane1r2(34), St.Martin-Antilles CAS
tre1r2(35), Turkey CAS
ile1r2(36), Israel CAS
moe1r2(37), Macau CAS
ine1r2-1(38), India sig1 CAS
ine1r2-2(39), India sig2 CAS
ine1r2-3(40), India sig3 CAS
ine1r2-4(41), India sig4 CAS
twt1(42), Taiwan (wink) CAS
ust1fc(43), Unites States CAS
ust1fdi(44), Unites States CAS
ni2-nfas-primary(45), NI-2 (National ISDN 2) T1 ISDN PRI
ni2-nfas-backup(46), NI-2 (National ISDN 2) T1 ISDN PRI
dms-nfas-primary(47), DMS-100 (Northern Telecom) T1 ISDN PRI
dms-nfas-backup(48) DMS-100 (Northern Telecom) T1 ISDN PRI
This parameter is available on all platforms using
PRI module and platforms using the WAN module
configured for CAS or PRI. You must reset the box
for the new switch-type to take effectrw Enumeration .1.3.6.1.4.1.15.2.11.2.1.15 |
anxt1BlockInCallsWhen this object is set to enable, then the box
will stop accepting calls on this line. This will
prevent new users from logging in and should be used
to bring the box down gracefully. The default
is disable.
This object is supported for modules configured
for PRI.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.16 |
anxt1BlockOutCallsWhen this object is set to enable, then the box
will not place any outgoing calls. This should be used
to bring the box down gracefully. The default
is disable.
This object is supported for modules configured
for PRI.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.17 |
anxt1LineLengthThis parameter allows the user to configure
the dsx1 line driver with the distance
between the annex and the external CSU. This paramater
should be left to default with annex's with internal CSU.
The parameter defines the line length in meters.
This MIB object corresponds to the na/admin
parameter dsx1-line-length.
This parameter is available on the ra6300, and on platforms
using the WAN module configured for CAS or PRI.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.18 |
anxt1AnalogEncodingThis parameter defines the type of encoding
to be used for analog (modem) calls. If this parameter
is not set then RA6300 will determine itself depending
on the PRI line that it terminates. For PRI line in
USA, this is set to mu-law and in Europe this will be
set to a-law.
This MIB object corresponds to the na/admin
parameter analog-encoding.
Default value is auto(1).
This parameter is available on the ra6300, and on platforms
using the WAN module configured for CAS or PRI.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.19 |
anxt1PRIModuleTypeThis object returns the module type on .
e1(1) means PRI module is for Europe,
t1(2) means PRI module is for USA with External CSU,
t1-intcsu(3) t1/PRI for USA with internal CSU.
e1-aust(4) e1/PRI for Australia.
cas-t1-csu(8) t1/CAS with internal csu.
cas-e1(9) e1/CAS.
This parameter is available on all platforms using
PRI module and platforms using the WAN module
configured for CAS or PRI.ro Enumeration .1.3.6.1.4.1.15.2.11.2.1.20 |
anxt1CasDnisDigitsThis parameter allows the user to configure the number of
DNIS digits that the channelized T1/E1 interface is provisioned
to provide. The default value is 0.
Typical values are between 4 - 10.
This MIB object corresponds to the na/admin
parameter dnis.
This parameter is available on platforms
using the WAN module configured for CAS.rw INTEGER .1.3.6.1.4.1.15.2.11.2.1.21 |
anxt1CasAniDigitsThis parameter allows the user to configure the number of
ANI digits that the channelized T1/E1 interface is provisioned
to provide. The default value is 0.
Typical values are between 4 - 10.
This MIB object corresponds to the na/admin
parameter ani.
This parameter is available on platforms
using the WAN module configured for CAS.rwdeprecated INTEGER .1.3.6.1.4.1.15.2.11.2.1.22 |
anxt1CasDigitWidthThis parameter allows the width of each digit generated by
the WAN module to be adjusted. The default value is 0.
This MIB object corresponds to the na/admin
parameter digit-width.
This parameter is available on platforms
using the WAN module configured for CAS.rw INTEGER .1.3.6.1.4.1.15.2.11.2.1.23 |
anxt1CasInterDigitThis parameter allows the distance between each digit
generated by the WAN module to be adjusted. The default
value is 0.
This MIB object corresponds to the na/admin
parameter inter-digit.
This parameter is available on platforms
using the WAN module configured for CAS.rw INTEGER .1.3.6.1.4.1.15.2.11.2.1.24 |
anxt1CasDigitPower1This parameter allows the power level of the FIRST tone
of each digit generated by the WAN module to be adjusted.
The default value is 0.
This MIB object corresponds to the na/admin
parameter digit-power-1.
This parameter is available on platforms
using the WAN module configured for CAS.rw INTEGER .1.3.6.1.4.1.15.2.11.2.1.25 |
anxt1CasDigitPower2This parameter allows the power level of the SECOND tone
of each digit generated by the WAN module to be adjusted.
The default value is 0.
This MIB object corresponds to the na/admin
parameter digit-power-2.
This parameter is available on platforms
using the WAN module configured for CAS.rw INTEGER .1.3.6.1.4.1.15.2.11.2.1.26 |
anxt1CasBusySignalBitsAn enumerated integer that defines the type of
busy signal.
This MIB object corresponds to the na/admin
parameter busy-signal-bits.
This parameter is available on platforms using the
WAN module configured for CAS.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.27 |
anxt1CasPhoneNumberThe local phone number of the WAN interface.
This MIB object corresponds to the na/admin parameter
local-phone-number.
This parameter is available on platforms using the
WAN module configured for CAS.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.11.2.1.28 |
anxt1Dsx1LineTypeThis variable indicates the variety of DS1
Line implementing this circuit. The type of
circuit affects the number of bits per second
that the circuit can reasonably carry, as well
as the interpretation of the usage and error
statistics. The values, in sequence, describe:
TITLE: rfc1406 TITLE: SPECIFICATION:
ESF(2) dsx1ESF Extended SuperFrame DS1
D4(3) dsx1D4 AT&T D4 format DS1
DDF(4) dsx1E1/ CCITT Recommendation G.704
dsxE1-MF (Table 4a)
MFF-CRC4(5) dsx1E1-CRC/ CCITT Recommendation G.704
dsx1E1-CRC-MF (Table 4b)
MFF-CRC4-G706(6) N/A 5399 WAN Module Func. Spec.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.29 |
anxt1Ds1EsfFdlThe NA parameter is tni-esf-fdl (channelized T1 category):
This specifies one of two standards when running ESF framing
on the T1 Network Interface: Valid options are ansi, attrwdeprecated Enumeration .1.3.6.1.4.1.15.2.11.2.1.30 |
anxt1TniCircuitIdThe NA parameter is tni-circuit-id (channelized T1 category):
This is a ascii string with circuit id provided by the
telephone company. Up to 127 bytes.
This object is supported for T1 engines only.rwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.11.2.1.31 |
anxt1TniClockThe NA parameter is tni-clock (channelized T1 category):
This specifies the T1 engine clock source: loop, local,
external.
This object is supported for T1 engines only.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.11.2.1.32 |
anxt1CallbackEnableWhen this object is set to enable, the WAN interface may be
selected to handle a callback pending port availability.
When set to disable, the associated WAN interface cannot be
selected as a callback resource. The default is disable.
This MIB object corresponds to the NA/admin WAN
parameter 'callback-enable'.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.33 |
anxt1CasAniEnableThis parameter allows the user to configure whether or not to
allow CAS ANI digits, (per provisioning). The default is disable.
This MIB object corresponds to the na/admin WAN
parameter 'ani'.
This parameter is available on platforms
using the WAN module configured for CAS.rw Enumeration .1.3.6.1.4.1.15.2.11.2.1.34 |
anxt1NfasinterfaceidThis is a configurable parameter for NFAS.
This MIB object corresponds to the NA/admin WAN
parameter 'nfas-interface-id'.rw INTEGER .1.3.6.1.4.1.15.2.11.2.1.35 |
anxt1BackupinterfaceidThis is a configurable parameter for NFAS.
This MIB object corresponds to the NA/admin WAN
parameter 'backup-interface-id'.rw INTEGER .1.3.6.1.4.1.15.2.11.2.1.36 |
anxt1ChanTableTable of DS0 channel entries. SEQUENCE OF Anxt1ChanEntry .1.3.6.1.4.1.15.2.11.3 |
anxt1ChanEntryThe internal T1 engine parameters. Anxt1ChanEntry .1.3.6.1.4.1.15.2.11.3.1 |
anxt1ChanIndexThe index value which uniquely identifies the
WAN interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module.ro INTEGER (1..'7fffffff'h) .1.3.6.1.4.1.15.2.11.3.1.1 |
anxt1ChanNumberA unique number from 1 to anxt1TotChan that
identifies each internal DS0 channel on a WAN interface.ro INTEGER .1.3.6.1.4.1.15.2.11.3.1.2 |
anxt1ChanMapThis object specifies the mapping between the DS0
in the DS1 interface, the DS0 in the DI interface,
and the modems. The DS0 is identified by anxt1ChanIfIndex
and anxt1ChanNumber. This object has two 8-bit fields.
The high byte specifies the mapping:
unused(1),
ds1-modem(2), (ds1 to modem)
di-modem(3), (di to modem)
voice(4), (ds1 to di with voice signaling)
data(5) (ds1 to di with data signaling)
The low byte is used only when the high byte specifies
ds1-modem or di-modem and should be ignored in all other
cases. The low byte specifies the modem number (same as
port number) being mapped to the DS0.
Note: when the type is set to either voice, data or unused
agent expects zeros in the modem octet eg:'0400'
Corresp. na/admin parameter is the map.
This object is only valid for T1 products.rwdeprecated OCTET STRING .1.3.6.1.4.1.15.2.11.3.1.3 |
anxt1ChanSigProtoThis object is meaningful only when anxt1ChanMap is set
to ds1-modem or di-modem and should be ignored in all
other cases. The supported protocols are:
none(1),
loop-start(2),
ground-start(3),
wink-start(4),
immediate-start(5)
Note: following combinations are considered valid:
Value InSig octet OutSig octet
-
22 loop-start loop-start
21 loop-start none
12 none loop-start
33 ground ground
31 ground none
13 none ground
44 wink wink
41 wink none
14 none wink
51 immediate none
15 none immediate
11 none none
sigproto is the na/admin corresponding parameter.
This object is not valid for RA6300 only.rw Enumeration .1.3.6.1.4.1.15.2.11.3.1.4 |
anxt1ChanRingThis object is meaningful only when anxt1ChanMap is set
to ds1-modem or di-modem and should be ignored in all
other cases. This object specifies if the Annex should
provide the audible ring to the central office on incoming
calls. The default is NO.
Corresp. na/admin parameter is the ring.
This parameter is available on the ra6300, and on platforms
using the WAN module configured for PRI.rw Enumeration .1.3.6.1.4.1.15.2.11.3.1.5 |
anxt1ChanIpAddrThis object returns the IP address
associated with the B Channel. When needed, this
IP address will be used for calls over the B channel.
This parameter is available on the ra6300, and on platforms
using the WAN module (configured for CAS or PRI).rw IpAddress .1.3.6.1.4.1.15.2.11.3.1.6 |
anxt1ChanIpxNetworkThe IPX network number for an IPX PPP connection
using this port. When the IPX PPP connection is
established the network number will be negotiated.
If one end of the connection is set to zero then
the value from the other end of the connection will
be used.
The value of this object is an 8 digit hexadecimal
number string representing the IPX network segment
assigned to this port. The value must be unique
across the network domain.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ppp-ipx-network'.rw DisplayString .1.3.6.1.4.1.15.2.11.3.1.7 |
anxt1ChanIpxNodeThe IPX node number for an IPX PPP connection
using this port.
The value of this object is a 12 digit
hexadecimal number string representing the IPX
node number assigned to this port.
Note the string is expected in the form:
12-3a-4-7-89-23.Each part of the address
must be a hex value separated by a hyphen.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ppp-ipx-node'.rw DisplayString .1.3.6.1.4.1.15.2.11.3.1.8 |
anxt1ChanStatusThis object returns the status of the
B channel. This is a read-only object that
indicates whether the channel is in use or not.ro Enumeration .1.3.6.1.4.1.15.2.11.3.1.9 |
anxt1ChanStateThis object reflects the state of the
B channel. Available means it is open
for use, busied-out means it was manually
taken out of the pool for use, and
auto-busied-out means the box removed
this channel for use because there are
more channels than modems available.
This object can be set and changes the state of
the channel. auto-busied-out cannot be set by a user.rw Enumeration .1.3.6.1.4.1.15.2.11.3.1.10 |
anxt1ChanSeizeSEIZE message from a WAN module to a WAN
manager process on the main processor,
indicating that the central office switch
has sent a channelized T1/E1 seize event.ro Counter .1.3.6.1.4.1.15.2.11.3.1.11 |
anxt1ChanRingCountRING message from a WAN module to a WAN
manager process on the main processor,
indicating that a call has arrived. Successful
completion of assigning a modem and starting a
session.ro Counter .1.3.6.1.4.1.15.2.11.3.1.12 |
anxt1ChanAssignNo modems were available for assignment.
This is caused by not having enough modems
or modems being removed from the poolro Counter .1.3.6.1.4.1.15.2.11.3.1.13 |
anxt1ChanConnectCONNECT message from the WAN module to the
WAN manager process, meaning the 5399 has
accepted the call and the WAN module and the
telephone company switch have agreed that the
call is up.ro Counter .1.3.6.1.4.1.15.2.11.3.1.14 |
anxt1ChanChatThere was a modem error and the call was
terminated. Possibly caused by the modem.ro Counter .1.3.6.1.4.1.15.2.11.3.1.15 |
anxt1ChanDcdModem did not establish a connection with
it's peer. Lots of possible causes:
many possible causes:
modem error
bad data from bad channel
end-to-end line quality low
caller hung up
calling device wasn't a modemro Counter .1.3.6.1.4.1.15.2.11.3.1.16 |
anxt1ChanModemCallThe number of times an incoming modem
call failed before getting all the way
to DCD.ro Counter .1.3.6.1.4.1.15.2.11.3.1.17 |
anxt1ChanConsecFailThe number of times an incoming non-modem
call failed before successfully assigning
a device.ro Counter .1.3.6.1.4.1.15.2.11.3.1.18 |
anxt1CurrentTableTable of extended T1 current statistics.
This table is valid for WAN module platforms only. SEQUENCE OF Anxt1CurrentEntry .1.3.6.1.4.1.15.2.11.4 |
anxt1CurrentEntryThe internal T1 engine extended current statistics. Anxt1CurrentEntry .1.3.6.1.4.1.15.2.11.4.1 |
anxt1CurrentIndexThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER .1.3.6.1.4.1.15.2.11.4.1.1 |
anxt1CurrentOofsAn Out Of Frame (OOF) event begins when any two
of four consecutive frame synchronizing bits are
received from the network interface are incorrect.
An OOF state ends when reframe occurs.ro Counter .1.3.6.1.4.1.15.2.11.4.1.2 |
anxt1CurrentBpvsA BiPolar Violations error event for an AMI-coded
signal is the occurence of a pulse of the same polarity
as the previous pulse. A BPV error event for a B8ZS or
HDB3 coded signal is the occurence of a pulse of the
same polarity as the previous pulse without being a
part of the zero substitution code.ro Counter .1.3.6.1.4.1.15.2.11.4.1.3 |
anxt1CurrentCrcsA CRC error occurs when the CRC field calculated
by the customer installation, based on the incoming
DS1 signal does not agree with the CRC field contained
in the DS1 signal received from the network.ro Counter .1.3.6.1.4.1.15.2.11.4.1.4 |
anxt1CurrentCsA Controlled Slips is the occcurence of a replication
or deletion of a DS1 frame by the receiving terminal.ro Counter .1.3.6.1.4.1.15.2.11.4.1.5 |
anxt1CurrentRnacsReceive Network Alarm seconds is the count of seconds
with at least one alarm event occurring in a second.ro Counter .1.3.6.1.4.1.15.2.11.4.1.6 |
anxt1CurrentEsfsThe count of extended superframe errors in the current
interval.ro Counter .1.3.6.1.4.1.15.2.11.4.1.7 |
anxt1CurrentLofcsThe count of loss of framing errors in the current
interval.ro Counter .1.3.6.1.4.1.15.2.11.4.1.8 |
anxt1IntervalTableTable of extended T1 interval statistics.
This table is valid for WAN module platforms only. SEQUENCE OF Anxt1IntervalEntry .1.3.6.1.4.1.15.2.11.5 |
anxt1IntervalEntryThe internal T1 engine extended interval statistics. Anxt1IntervalEntry .1.3.6.1.4.1.15.2.11.5.1 |
anxt1IntervalIndexThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER .1.3.6.1.4.1.15.2.11.5.1.1 |
anxt1IntervalNumberA number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid).ro INTEGER .1.3.6.1.4.1.15.2.11.5.1.2 |
anxt1IntervalOofsAn Out Of Frame (OOF) event begins when any two
of four consecutive frame synchronizing bits are
received from the network interface are incorrect.
An OOF state ends when reframe occurs.ro Counter .1.3.6.1.4.1.15.2.11.5.1.3 |
anxt1IntervalBpvsA BiPolar Violations error event for an AMI-coded
signal is the occurence of a pulse of the same polarity
as the previous pulse. A BPV error event for a B8ZS or
HDB3 coded signal is the occurence of a pulse of the
same polarity as the previous pulse without being a
part of the zero substitution code.ro Counter .1.3.6.1.4.1.15.2.11.5.1.4 |
anxt1IntervalCrcsA CRC error occurs when the CRC field calculated
by the customer installation, based on the incoming
DS1 signal does not agree with the CRC field contained
in the DS1 signal received from the network.ro Counter .1.3.6.1.4.1.15.2.11.5.1.5 |
anxt1IntervalCsA Controlled Slips is the occcurence of a replication
or deletion of a DS1 frame by the receiving terminal.ro Counter .1.3.6.1.4.1.15.2.11.5.1.6 |
anxt1IntervalRnacsReceive Network Alarm seconds is the count of seconds
with at least one alarm event occurring in a second.ro Counter .1.3.6.1.4.1.15.2.11.5.1.7 |
anxt1IntervalEsfsThe count of extended superframe errors in this interval.ro Counter .1.3.6.1.4.1.15.2.11.5.1.8 |
anxt1IntervalLofcsThe count of loss of framing errors in this interval.ro Counter .1.3.6.1.4.1.15.2.11.5.1.9 |
anxt1TotalTableTable of extended T1 total statistics.
This table is valid for WAN module platforms only. SEQUENCE OF Anxt1TotalEntry .1.3.6.1.4.1.15.2.11.6 |
anxt1TotalEntryThe internal T1 engine extended total statistics. Anxt1TotalEntry .1.3.6.1.4.1.15.2.11.6.1 |
anxt1TotalIndexThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER .1.3.6.1.4.1.15.2.11.6.1.1 |
anxt1TotalOofsAn Out Of Frame (OOF) event begins when any two
of four consecutive frame synchronizing bits are
received from the network interface are incorrect.
An OOF state ends when reframe occurs.ro Counter .1.3.6.1.4.1.15.2.11.6.1.2 |
anxt1TotalBpvsA BiPolar Violations error event for an AMI-coded
signal is the occurence of a pulse of the same polarity
as the previous pulse. A BPV error event for a B8ZS or
HDB3 coded signal is the occurence of a pulse of the
same polarity as the previous pulse without being a
part of the zero substitution code.ro Counter .1.3.6.1.4.1.15.2.11.6.1.3 |
anxt1TotalCrcsA CRC error occurs when the CRC field calculated
by the customer installation, based on the incoming
DS1 signal does not agree with the CRC field contained
in the DS1 signal received from the network.ro Counter .1.3.6.1.4.1.15.2.11.6.1.4 |
anxt1TotalCsA Controlled Slips is the occcurence of a replication
or deletion of a DS1 frame by the receiving terminal.ro Counter .1.3.6.1.4.1.15.2.11.6.1.5 |
anxt1TotalRnacsReceive Network Alarm seconds is the count of seconds
with at least one alarm event occurring in a second.ro Counter .1.3.6.1.4.1.15.2.11.6.1.6 |
anxt1TotalEsfsThe total count of extended superframe errors.ro Counter .1.3.6.1.4.1.15.2.11.6.1.7 |
anxt1TotalLofcsThe total count of loss of framing errors.ro Counter .1.3.6.1.4.1.15.2.11.6.1.8 |
anxt1WanModuleTableThis table is is used to cross reference a WAN
module to its ifindex. SEQUENCE OF Anxt1WanModuleEntry .1.3.6.1.4.1.15.2.11.7 |
anxt1WanModuleEntryWAN module table entry. Anxt1WanModuleEntry .1.3.6.1.4.1.15.2.11.7.1 |
anxt1WanIndexThis is the index of the physical WAN module in
any BAY remote access product that uses WAN modules.
The range is 1 - anxt1Total (number of WAN modules in box)ro INTEGER .1.3.6.1.4.1.15.2.11.7.1.1 |
anxt1WanIfIndexThis object can be used in place of Ifindex to find
the interface number of a WAN module.ro INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.11.7.1.2 |
anxt1TotalChannelsThe total number of channels (Ds0's) on the this box
(or blade).ro INTEGER .1.3.6.1.4.1.15.2.11.8 |
anxt1BusiedOutChannelsThe number of channels that are busied out.
anxt1TotalChannels - anxt1BusiedOutChannels =
Number of available channelsro INTEGER .1.3.6.1.4.1.15.2.11.9 |
wanStatTableTable of Wan Module statistics.
This table is valid for WAN module platforms only. SEQUENCE OF WanStatEntry .1.3.6.1.4.1.15.2.11.10 |
wanStatEntryThe internal T1 engine extended current statistics. WanStatEntry .1.3.6.1.4.1.15.2.11.10.1 |
wanStatIndexThe ifIndex value in the interfaces
table.
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER .1.3.6.1.4.1.15.2.11.10.1.1 |
wanStatInterfaceErrsThis counter is incremented when ever an
error occurs between the wan module and the
PRI manager.ro Counter .1.3.6.1.4.1.15.2.11.10.1.2 |
wanStatAcceptedInCallsNumber of incoming calls accepted by the call handler.
(call handler is generic term for all types of signaling
methods)ro Counter .1.3.6.1.4.1.15.2.11.10.1.3 |
wanStatRejectedInCallsNumber of incoming calls rejected by the call handler.
(call handler is generic term for all types of signaling
methods)ro Counter .1.3.6.1.4.1.15.2.11.10.1.4 |
wanStatAcceptedOutCallsNumber of outgoing calls accepted by the call handler.
(call handler is generic term for all types of signaling
methods)ro Counter .1.3.6.1.4.1.15.2.11.10.1.5 |
wanStatRejectedOutCallsNumber of outgoing calls rejected by the call handler.
(call handler is generic term for all types of signaling
methods)ro Counter .1.3.6.1.4.1.15.2.11.10.1.6 |
wanStatNormalCallDisconnectsNumber of normal disconnects.
Normal Disconnects cause codes:
- NORMAL-CALL-CLEARING-CCODro Counter .1.3.6.1.4.1.15.2.11.10.1.7 |
wanStatAbNormalCallDisconnectsNumber of abnormal disconnects.
Abnormal Disconnects cause codes:
- INVALID-NUMBER-FORMAT-CCODE
- NO-CKT-CHAN-AVAIL-CCODE
- REQ-CHAN-NOT-AVAIL-CCODEro Counter .1.3.6.1.4.1.15.2.11.10.1.8 |
wanStatBchansCurrAllocatedNumber of B channels currently allocated.ro INTEGER .1.3.6.1.4.1.15.2.11.10.1.9 |
wanStatNumTimesWanFullNumber of times this wan has had all B channels
allocated since the wan-manager process was started
on the wan module. The wan-manager process is
started at boot time or by using the cli
-control- command to stop it and restart
it on a given wan module.ro Counter .1.3.6.1.4.1.15.2.11.10.1.10 |
connections OBJECT IDENTIFIER .1.3.6.1.4.1.15.2.12.1 |
RFC1213-MIB Unknown .1.3.6.1.4.1.15.2.12.1 |
callGenericTableTable of entries of generic parameters for
active calls. SEQUENCE OF CallGenericEntry .1.3.6.1.4.1.15.2.12.1.1 |
callGenericEntryThe call's generic parameters. CallGenericEntry .1.3.6.1.4.1.15.2.12.1.1.1 |
callGenericLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.1.1.1 |
callGenericIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.1.1.2 |
callGenericModeMode assigned to the port. Valid only
if the port type is async, or ta. The default
is cli.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'mode'.
Note: Values 6 and 12 are not used.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.3 |
callGenericLocationA descriptive string for this port. This
string is displayed by the CLI who command.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
location.ro DisplayString .1.3.6.1.4.1.15.2.12.1.1.1.4 |
callGenericTermVarA string defining the type of terminal
attached to the serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'term-var'.
Note: This object is not valid if the port type
is synchronous.ro DisplayString .1.3.6.1.4.1.15.2.12.1.1.1.5 |
callGenericPromptThis parameter defines a port-specific prompt
string. The prompt string consists of displayable
characters and embedded formatting codes. Each
formatting code is stored in a single character
in nonvolatile memory. The maximum number of
characters stored for the prompt string
is 16. Since the formatting codes consist of
a '%' prepended to a single character, the maximum
length string that may be entered for this object
is 32 characters. Strings less than 32
characters in length will be rejected as bad values
if they cannot be stored into 16 characters in
nonvolatile memory after the formatting codes are
compressed into single characters.
The valid formatting codes are:
%a the string 'annex'
%c the string ': '
%d the date and time
%i the Annex's IP address
%j a newline character
%l port location, or 'port n'
%n the Annex's name
%p the port number
%r the string 'port'
%s a space
%t the time hh:mm:ss
%u the user name for port
%% the string '%'
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'prompt'.
Note: This object is not valid for
synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.1.1.6 |
callGenericAllowBcastControls whether the serial/ta port can
receive administrative broadcast messages.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'allow-broadcast'.
Note: This object is not valid for
synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.8 |
callGenericImask7BitsWhen enabled, instructs the Annex to ignore
the eighth bit of all received characters
on the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'imask-7bits'.
Note: This object is not valid for Synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.10 |
callGenericCliImask7Defines whether input at the CLI is masked to
7 bits. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli-imask7' The
default value for this object is enabled.
Note: This object is not valid for Synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.11 |
callGenericBannerSpecifies whether the Annex banner and message-
of-the-day are displayed on the channel. The
default is enabled.
This has four possible actions:
default, Y, yes, unset: banner before security,
motd after
none, N: no banner or motd
beforesec: banner and motd before
security
aftersec: banner and motd after
security
motd-before-sec: motd before security; no
banner
motd-after-sec: motd after security; no
banner
This MIB object corresponds to the NA/admin
NA/Admin Global Port parameter 'banner'.
Note: This object is not valid for Synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.12 |
callGenericTcpKeepAliveThe default keep-alive value for connections
to this serial port. If this is zero, use the
value specified by anxTcpKeepAlive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tcp-keepalive'.
Note: This object is not valid for Synchronous ports.ro INTEGER .1.3.6.1.4.1.15.2.12.1.1.1.13 |
callGenericDedicatedArgsCommand line arguments passed to process
started by a dedicated port with mode set
to 'telnet', 'tn3270', 'rlogin', 'connect'
(if LAT is in use) or 'call'. This object is
not valid for TA ports.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'dedicated-arguments'.
Note: This object is not valid for Synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.1.1.14 |
callGenericModemVarA string defining the type of modem attached
to the serial port. This object is not valid
for TA ports. This is always set to
'microcom'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'type-of-modem'.
Note: This object is not valid for
synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.1.1.15 |
callGenericDefSessModeThe default session mode when the DECServer
command interface is configured. The default
is interactive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'default-session-mode'.
Note: This object is not valid for Synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.16 |
callGenericResolveProtocolDefault host protocol to use when starting a
dedicated port and the protocol is not
explicitly specified in the command. Is set
to one of 'telnet', connect, or any. Any
means to try LAT (connect) first and if that
fails, try telnet.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'resolve-protocol.
Note: This object is not valid for Synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.17 |
callGenericMaxSessionThe maximum number of concurrent sessions allowed
on the port. A value of -1 indicates no maximum.
Setting the maximum to less than the current
number of sessions has unspecified results. This MIB
object corresponds to the NA/Admin parameter
'max-session-count'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.1.1.18 |
callGenericSpeedThe maximum speed of the port for this call.ro DisplayString .1.3.6.1.4.1.15.2.12.1.1.1.19 |
callGenericAutoBaudThis is always set to disabled.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.20 |
callGenericJobsJob list for this cli session.ro DisplayString .1.3.6.1.4.1.15.2.12.1.1.1.21 |
callGenericLineTypeThis is what the port is running at the moment.
callgenericmode will tell you what the port is
configured to run through the spb or e2rom.ro Enumeration .1.3.6.1.4.1.15.2.12.1.1.1.22 |
callSignalTableTable of entries for port flow control and
signal parameters. SEQUENCE OF CallSignalEntry .1.3.6.1.4.1.15.2.12.1.2 |
callSignalEntryThe table of entries of flow control and
signal parameters for active calls. CallSignalEntry .1.3.6.1.4.1.15.2.12.1.2.1 |
callSignalLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.2.1.1 |
callSignalIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.2.1.2 |
callSignalInputStartCharThe control character sequence that restarts
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'input-start-char'.
Note: This object is not valid for
Synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.2.1.4 |
callSignalInputStopCharThe control character sequence that stops
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'input-stop-char'.
Note: This object is not valid for
Synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.2.1.5 |
callSignalOutputStartCharThe control character sequence that restarts
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'output-start-char'.
Note: This object is not valid for
Synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.2.1.6 |
callSignalOutputStopCharThe control character sequence that stops
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'output-stop-char'.
Note: This object is not valid for
Synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.2.1.7 |
callSignalIxanyFlowCtrlThis parameter specifies whether any input
character will be treated as a start (xon)
character when output has been suspended by
a stop (xoff) character.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ixany-flow-control'.
Note: This object is not valid for Synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.2.1.8 |
callSignalForwardKeyDefines a control character sequence as an
attention character to switch the user to
the next session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forward-key'.
Note: This object is not valid for Synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.2.1.10 |
callSignalBackwardKeyDefines a control character sequence as an
attention character to switch the user to
the previous session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'Backward-key'.
Note: This object is not valid for Synchronous ports.ro DisplayString .1.3.6.1.4.1.15.2.12.1.2.1.11 |
callSignalCharInFlowThe port's type of input flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'eia'(hardware)
indicates flow control delegated to the lower level,
for example a parallel port.ro Enumeration .1.3.6.1.4.1.15.2.12.1.2.1.17 |
callSignalCharOutFlowThe port's type of output flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'eia'(hardware)
indicates flow control delegated to the lower level,
for example a parallel port.ro Enumeration .1.3.6.1.4.1.15.2.12.1.2.1.18 |
callSignalrs232AsyncBitsThe port's number of bits in a character. This object
corresponds to the admin parameter data-bits.rwdeprecated INTEGER .1.3.6.1.4.1.15.2.12.1.2.1.19 |
callSignalrs232AsyncStopBitsThe port's number of stop bits. This object corresponds
to the admin parameter stop-bits.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.2.1.20 |
callSignalrs232AsyncParityThe port's sense of a character parity bit.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.2.1.21 |
callLoginTableTable of entries of login parameters for
active calls.
Note: This table is not valid for Synchronous ports. SEQUENCE OF CallLoginEntry .1.3.6.1.4.1.15.2.12.1.3 |
callLoginEntryCall's login user parameters. CallLoginEntry .1.3.6.1.4.1.15.2.12.1.3.1 |
callLoginLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.3.1.1 |
callLoginIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.3.1.2 |
callLoginVciLoginPortPasswdIndicates if the port is configured as a
DECServer interface port. The default is
disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'login-port-password'.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.3.1.3 |
callLoginVciLoginTimeoutEnables a login timer if the port is
configured as a DECServer interface port. The
default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'login-timeout'.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.3.1.4 |
callTimerTableTable of entries of port timer and counter
parameters for active calls.
Note: This table is not valid for Synchronous ports. SEQUENCE OF CallTimerEntry .1.3.6.1.4.1.15.2.12.1.4 |
callTimerEntryCall's timer and counter parameters. CallTimerEntry .1.3.6.1.4.1.15.2.12.1.4.1 |
callTimerLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.4.1.1 |
callTimerIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.4.1.2 |
callTimerForwardTimerThis parameter defines the inter-character
timer that sets the amount of time, in tens of
milliseconds, that will elapse before
forwarding the received data. The value of
5 turns means the timer is off.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'forwarding-timer'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.4.1.3 |
callTimerForwardCountSpecifies the number of received characters
buffered for the port by the Annex before
forwarding the characters to the host or
network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'forwarding-count'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.4.1.4 |
callTimerCliInactivityThe amount of time, in minutes, that the
Annex waits before hanging up the serial/ta
port after it becomes idle. A value of 0
indicates the timer is off. A value of 255
means immediate, which causes the Annex to
hang up the port immediately after exiting
from the last job.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'cli-inactivity'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.4.1.5 |
callTimerCliInactivityTimerThe amount of time, in minutes, which a port
can remain inactive before the Annex
terminates all sessions and resets the port. A
value of 0 implies timer is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'inactivity-timer'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.4.1.6 |
callTimerInputIsActivityControls whether received input characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'input-is-activity'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.4.1.7 |
callTimerOutputIsActivityControls whether transmitted output
characters are considered as activity for the
port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'output-is-activity'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.4.1.8 |
callTimerResetIdleTimerDefines whether input or output resets the
idle timer for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'reset-idle-time-on'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.4.1.9 |
callTimerLongBreakThis parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break greater than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'long-break'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.4.1.10 |
callTimerShortBreakThis parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break shorter than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'short-break'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.4.1.11 |
callSecurityTableTable of entries of port security parameters
for active calls. SEQUENCE OF CallSecurityEntry .1.3.6.1.4.1.15.2.12.1.5 |
callSecurityEntryCall's security parameters. CallSecurityEntry .1.3.6.1.4.1.15.2.12.1.5.1 |
callSecurityLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.5.1.1 |
callSecurityIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.5.1.2 |
callSecurityUserNameA string defining the default user name for
the user of this serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'user-name'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.5.1.3 |
callSecurityCliThis parameter controls whether security is
enabled for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'cli-security'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.5.1.4 |
callSecurityConnectThis parameter controls whether the
host-based security policy is enabled for
access from the port to the network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'connect-security'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.5.1.5 |
callSecurityPortServerThis parameter controls whether the
host-based security policy is enabled for
access to the port from the port server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'port-server-security'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.5.1.6 |
callSecurityPortPasswdThis parameter defines a password for the
port for local password protection.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'port-password'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.5.1.7 |
callSecurityIpsoClassDefines the IP security classification for
packets sent and received on this port. The
default value is none.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ipso-class'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.5.1.8 |
callSecurityIpxControls whether IPX security is enabled on
this port. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'ipx-security'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.5.1.9 |
callSecurityCurrentUserReturns the username for an active call on a
b channel. This MIB object is only valid if
security is enabled.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.12.1.5.1.10 |
callLineEditTableTable of entries of line editing parameters
for active calls.
Note: This table is not valid for
synchronous ports. SEQUENCE OF CallLineEditEntry .1.3.6.1.4.1.15.2.12.1.6 |
callLineEditEntryCall's line editing parameters. CallLineEditEntry .1.3.6.1.4.1.15.2.12.1.6.1 |
callLineEditLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.6.1.1 |
callLineEditIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.6.1.2 |
callLineEditAttnCharDefines a control character sequence as an
attention character to return the user to
the CLI prompt. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'attn-string'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.6.1.3 |
callLineEditEchoThis parameter controls whether the Annex
echoes all characters as they are received
from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'echo'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.4 |
callLineEditTelnetEscapeDefines the control character that returns
the user to the 'telnet:' prompt when running
the CLI telnet command.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
The value 'U' means this feature is disabled
on this port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'telnet-escape'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.6.1.5 |
callLineEditTelnetCRLFDefines what characters are transmitted
out the port to the network when the
End-of-Line character is sensed. 'enabled'
means transmit Line-Feed and Carriage-Return.
'disabled' means transmit Carriage-Return
and NULL. The default is enabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'telnet-crlf'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.6 |
callLineEditMapToLowerWhen enabled, the Annex translates all upper
case characters to lower case as they are
received from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'map-to-lower'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.7 |
callLineEditMapToUpperWhen enabled, the Annex translates all lower
case characters to upper case as they are
transmitted to the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter '
map-to-upper'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.8 |
callLineEditCharEraseThis parameter controls whether the Annex
echoes the character erase and word erase
characters for a video terminal (enabled)
or for a hard-copy terminal (disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'char-erase'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.9 |
callLineEditEraseCharDefines the character erase control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase-char'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.6.1.10 |
callLineEditLineEraseThis parameter controls whether the Annex
echoes the line erase character for a video
terminal (enabled) or for a hard-copy terminal
(disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'line-erase'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.11 |
callLineEditEraseLineDefines the line erase control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase-line'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.6.1.12 |
callLineEditEraseWordDefines the word erase control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase-word'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.6.1.13 |
callLineEditHardwareTabsWhen enabled, this parameter allows the Annex
to expand ASCII tab characters.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'hardware-tabs'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.14 |
callLineEditRedisplayLineDefines the reprint line control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'redisplay-line'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.6.1.15 |
callLineEditToggleOutputDefines the flush control character used to
flush the output buffer.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'toggle-output'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.6.1.16 |
callLineEditNewLineTermThis parameter controls whether a carriage
return is echoed as just a carriage return
(enabled), or whether the carriage return is
echoed as a carriage return and line feed.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'newline-terminal'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.6.1.17 |
callNetTableTable of entries of networking protocol
parameters for active calls. SEQUENCE OF CallNetEntry .1.3.6.1.4.1.15.2.12.1.7 |
callNetEntryCall's networking protocol parameters. CallNetEntry .1.3.6.1.4.1.15.2.12.1.7.1 |
callNetLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.7.1.1 |
callNetIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.7.1.2 |
callNetLocalAddrThe Internet address for the Annex's side
of the point-to-point (SLIP or PPP) link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'local-address'.ro IpAddress .1.3.6.1.4.1.15.2.12.1.7.1.3 |
callNetRemoteAddrThe Internet address for the host at the
remote end of the point-to-point (SLIP or PPP)
link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'remote-address'.ro IpAddress .1.3.6.1.4.1.15.2.12.1.7.1.4 |
callNetMetricThis parameter defines the hop count to
the remote end of the SLIP or PPP interface.
This MIB object corresponds to the NA/admin
asynchronous, ta. synchronous port parameter
'metric'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.7.1.6 |
callNetSlipSecureIf anxEnableSecurity is disabled, this
parameter selects slip session logging. If
anxEnableSecurity is enabled, this parameter
permits slip access only from secure ports.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'slip-ppp-security'.
Note: This object is not valid for
Synchronous ports.ro Enumeration .1.3.6.1.4.1.15.2.12.1.7.1.7 |
callNetInactivityThe number of units allowed for serial
protocol inactivity on the port. The type of
unit, minutes or seconds, is defined by the
object anxpNetInactivityUnits. If the type of
units is 'seconds', the actual granularity is
only 5 seconds. When the interval expires,
the port is automatically reset. A value of 0
means the timer is disabled.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net-inactivity'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.7.1.8 |
callNetDoCompressionWhen enabled, the Annex will attempt to
negotiate TCP/IP header compression on this
serial link.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'do-compression'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.7.1.9 |
callNetAllowCompressionWhen enabled, the Annex will allow TCP/IP
header compression on this serial link only
if the other end of the serial link initiates
the compression.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'allow-compression'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.7.1.10 |
callNetInactivityUnitsThe type of units that are used for the
port's net inactivity timer. See also the
anxpNetInactivity object. The default value
is 'minutes'.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net-inactivity-units'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.7.1.11 |
callSlipTableTable of entries of Slip parameters for
active calls.
Note: This object is not valid for
Synchronous ports. SEQUENCE OF CallSlipEntry .1.3.6.1.4.1.15.2.12.1.8 |
callSlipEntryCall's Slip parameters. CallSlipEntry .1.3.6.1.4.1.15.2.12.1.8.1 |
callSlipLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.8.1.1 |
callSlipIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.8.1.2 |
callSlipSubnetMaskThe subnet mask for this SLIP interface.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'subnet-mask'.ro IpAddress .1.3.6.1.4.1.15.2.12.1.8.1.3 |
callSlipMtuSizeForce the compressed SLIP interface to use
a Maximum Transmission Unit (MTU) of either
1024 bytes (large) or 256 bytes (small). The
default is large.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'slip-mtu-size'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.8.1.4 |
callSlipNoIcmpWhen enabled, the Annex will discard any
ICMP packets directed to this SLIP link.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'slip-no-icmp'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.8.1.5 |
callSlipTosWhen enabled, the Annex sends interactive
traffic over this SLIP link before any other
traffic.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'slip-tos'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.8.1.6 |
callPPPTableTable of entries of PPP parameters for
active calls. SEQUENCE OF CallPPPEntry .1.3.6.1.4.1.15.2.12.1.9 |
callPPPEntryCall's PPP parameters. CallPPPEntry .1.3.6.1.4.1.15.2.12.1.9.1 |
callPPPLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.9.1.1 |
callPPPIdxA call's B channel number ranging from 1-30.ro INTEGER .1.3.6.1.4.1.15.2.12.1.9.1.2 |
callPPPMruThis parameter defines the maximum receive
unit in bytes. The default value is 1500.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter 'ppp-mru'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.9.1.3 |
callPPPAcmThis parameter specifies which of the first
32 bytes (0x00, ... 0x1F) can be sent as
clear text and which need to be escaped. A
bit on in the mask indicates the character
must be escaped. The mask should be specified
as an 8 hex character string (0x1F000000 and
1F000000 are both acceptable).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ppp-acm'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.9.1.4 |
callPPPSecurityProtoDefines which security protocol will be used
to authenticate the remote user. This
parameter must be set and the Annex
enable-security (anxEnableSecurity) must be
enabled before authentication is performed.
The default is none
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'ppp-security-protocol'.ro Enumeration .1.3.6.1.4.1.15.2.12.1.9.1.5 |
callPPPRemoteUserThe username used by the Annex to identify
itself if the remote PPP peer asks for
authentication.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'ppp-username-remote'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.9.1.6 |
callPPPRemotePasswdThe password used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'ppp-password-remote'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.9.1.7 |
callPPPNcpA bitmask for PPP NCP Options:
0x0002 NCP-IPCP
0x0004 NCP-ATCP
0x0008 NCP-IPXCP
0x0010 NCP-MP
0x0020 NCP-CCP
0x0040 NCP-CBCP
Note: if the ncp-option parameter
is set to the value of 'all', the SNMP
agent will return the fully expanded bitmask
value instead of the 0x0001 value of 'all'.ro INTEGER .1.3.6.1.4.1.15.2.12.1.9.1.8 |
callPPPIpxNetworkThe IPX network number for an IPX PPP
connection using this port. When the IPX PPP
connection is established the network number
will be negotiated. If one end of the
connection is set to zero then the value from
the other end of the connection will be used.
The value of this object is an 8 digit
hexadecimal number string representing the
IPX network segment assigned to this port.
The value must be unique across the network
domain.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'ppp-ipx-network'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.9.1.9 |
callPPPIpxNodeThe IPX node number for an IPX PPP connection
using this port.
The value of this object is a 12 digit
hexadecimal number string representing the IPX
node number assigned to this port.
Note the string is expected in the form:
12-3a-4-7-89-23.Each part of the address
must be a hex value separated by a hyphen.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'ppp-ipx-node'.ro DisplayString .1.3.6.1.4.1.15.2.12.1.9.1.10 |
callPPPTraceLevelControls whether PPP trace messages are sent to the
syslog facility or not. The default value is none(0).
This MIB object corresponds to the na/admin port parameter
ppp-trace-level.rw Enumeration .1.3.6.1.4.1.15.2.12.1.9.1.11 |
callARAPTableTable of entries of Apple Talk parameters for
active calls.
Note: This object is not valid for
Synchronous ports.deprecated SEQUENCE OF CallARAPEntry .1.3.6.1.4.1.15.2.12.1.10 |
callARAPEntryCall's ARAP parameters.deprecated CallARAPEntry .1.3.6.1.4.1.15.2.12.1.10.1 |
callARAPLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulerodeprecated INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.10.1.1 |
callARAPIdxA call's B channel number ranging from 1-30.rodeprecated INTEGER .1.3.6.1.4.1.15.2.12.1.10.1.2 |
callARAPGuestIf enabled, allows ARAP guest login service.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at-guest'.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.10.1.3 |
callARAPNodeIdThe default AppleTalk node ID hint that is
used by the Annex on this port. The address
consists of two parts separated by a dot. The
address may be in either hex or decimal
format. The first part is the network address
and ranges from 0 to 65534 (0x0000 to 0xFFFE).
The second part is the node address and ranges
from 0 to 254 (0x00 to 0xFE).
Example:
0x00BF.0xFD 191.253 0x00BF.253 191.0xFD
are all the same address.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at-nodeid'.rodeprecated DisplayString .1.3.6.1.4.1.15.2.12.1.10.1.4 |
callARAPSecurityControls whether ACP service is enabled for
this port when establishing an AppleTalk
connection.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at-security'.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.10.1.5 |
callARAPV42BISControls whether V.42bis compression is done
during an ARAP session.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'arap-v42bis'.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.10.1.6 |
callTN3270TableTable of entries of TN3270 parameters for
active calls.
Note:This object is not valid for
Synchronous ports.deprecated SEQUENCE OF CallTN3270Entry .1.3.6.1.4.1.15.2.12.1.11 |
callTN3270EntryCall's TN3270 parameters.deprecated CallTN3270Entry .1.3.6.1.4.1.15.2.12.1.11.1 |
callTN3270LineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulerodeprecated INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.11.1.1 |
callTN3270IdxA call's B channel number ranging from 1-30.rodeprecated INTEGER .1.3.6.1.4.1.15.2.12.1.11.1.2 |
callTN3270PrinterHostThe IP address of the machine running a
Berkeley-style lpd server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'tn3270-printer-name'.rodeprecated IpAddress .1.3.6.1.4.1.15.2.12.1.11.1.3 |
callTN3270PrinterNameA valid printer name contained in the
/etc/printcap file on the remote host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'tn3270-printer-name'.rodeprecated DisplayString .1.3.6.1.4.1.15.2.12.1.11.1.4 |
callLATTableTable of entries of LAT parameters for
active calls.
Note:This object is not valid for
synchronous ports.deprecated SEQUENCE OF CallLATEntry .1.3.6.1.4.1.15.2.12.1.12 |
callLATEntryCall's LAT parameters.deprecated CallLATEntry .1.3.6.1.4.1.15.2.12.1.12.1 |
callLATLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulerodeprecated INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.12.1.1 |
callLATIdxA call's B channel number ranging from 1-30.rodeprecated INTEGER .1.3.6.1.4.1.15.2.12.1.12.1.2 |
callLATAuthMapThe syntax of this object is an octet string
32 bytes long, with the first byte
representing groups 0 through 7 and the last
byte representing groups 248 through 255.
For example, 0x40 0x25 ... means the groups
1,10,13,15 are valid for this port.
A returned value with all bits set to zero is
the same as setting 'group-value' to 'none'.
The object always returns a string 32 bytes
long.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'group-value'.rodeprecated OCTET STRING .1.3.6.1.4.1.15.2.12.1.12.1.3 |
callLATbEnableControls interpretation of LAT Data-B packets
received from host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'latb-enable'.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.12.1.4 |
callLATMultiSessionThis parameter allows multisession operation
to be managed on a per port basis. If
multisessions for the server has not been
enabled, any attempt to use this command will
cause the error message
'ETSMIN-786-Multisession feature Disabled'
to be displayed.
This MIB object corresponds to the NA/admin
port parameter 'multisessions'.
Note:
* SNMP will not check for the Annex
MultiSession parameter.
* Setting this MIB object is equivalent to
defining the port parameter 'multisession'
through NA/admin.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.12.1.5 |
callSetupTableTable of entries of call setup information
active calls.deprecated SEQUENCE OF CallSetupEntry .1.3.6.1.4.1.15.2.12.1.13 |
callSetupEntryCall's Setup information parameters.deprecated CallSetupEntry .1.3.6.1.4.1.15.2.12.1.13.1 |
callSetupLineIdxThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulerodeprecated INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to .1.3.6.1.4.1.15.2.12.1.13.1.1 |
callSetupIdxA call's B channel number ranging from 1-30.rodeprecated INTEGER .1.3.6.1.4.1.15.2.12.1.13.1.2 |
callSetupPortTypeA enumerated integer indicating the port
type. Detecting(4) means the annex is in the
process of detecting the port type.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.13.1.3 |
callSetupCallTypeThis object returns the whether the call is
incoming or outgoing.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.13.1.4 |
callSetupCallingTimeThis object returns the time the call has been
in progress. Measured in secondsrodeprecated INTEGER .1.3.6.1.4.1.15.2.12.1.13.1.5 |
callSetupCallingNbrThis object returns the calling number.rodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.12.1.13.1.6 |
callSetupCalledNbrThis object returns the number called.rodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.12.1.13.1.7 |
callSetupCalledSubAddrThis object returns called party subaddress.rodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.12.1.13.1.8 |
callSetupBearerThis object defines the bearer capability
of the incoing call. Possible values are
voice and data.rodeprecated Enumeration .1.3.6.1.4.1.15.2.12.1.13.1.9 |
callSetupPortNumberThis object returns the port number the call
is assigned to. This object in conjunction with the
object, port type, should be used to cross-reference
the information displayed by the CLI command 'who'.rodeprecated INTEGER .1.3.6.1.4.1.15.2.12.1.13.1.10 |
globals OBJECT IDENTIFIER .1.3.6.1.4.1.15.2.12.2 |
gpGenericModeThis parameter defines the mode for access
to the serial line or TA port.
The default is cli.
This MIB object corresponds to the NA/admin
asynchronous,ta, synchronous port parameter
'mode'.
Note: Values 6, 8, 9, 12, 13, 14, 15, and 18
cannot be set.rw Enumeration .1.3.6.1.4.1.15.2.12.2.1 |
gpGenericLocationA descriptive string for a this port. This
string is displayed by the CLI who command.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'location'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.2 |
gpGenericTermVarA string defining the type of terminal
attached to the serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'term-var'.
Note: This object is not valid for
synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.3 |
gpGenericPromptThis parameter defines a port-specific prompt
string. The prompt string consists of displayable
characters and embedded formatting codes. Each
formatting code is stored in a single character
in nonvolatile memory. The maximum number of
characters stored for the prompt string
is 16. Since the formatting codes consist of
a '%' prepended to a single character, the maximum
length string that may be entered for this object
is 32 characters. Strings less than 32
characters in length will be rejected as bad values
if they cannot be stored into 16 characters in
nonvolatile memory after the formatting codes are
compressed into single characters.
The valid formatting codes are:
%a the string 'annex'
%c the string ': '
%d the date and time
%i the Annex's IP address
%j a newline character
%l port location, or 'port n'
%n the Annex's name
%p the port number
%r the string 'port'
%s a space
%t the time hh:mm:ss
%u the user name for port
%% the string '%'
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'prompt'.
Note: This object is not valid for
synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.4 |
gpGenericCliInterfaceSpecifies either a Unix or VMS command line
interface. The default is uci.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'cli-interface'.
Note: This object is not valid for
synchronous ports.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.5 |
gpGenericAllowBcastControls whether the serial/ta port can
receive administrative broadcast messages.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'allow-broadcast'.
Note: This object is not valid for
synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.6 |
gpGenericBcastDirectionDefines the direction that an administrative
broadcast message is sent. This parameter is
valid only when the port is defined as a slave
port by the anxpMode parameter.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'broadcast-direction'.
Note: This object is not valid for Synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.7 |
gpGenericImask7BitsWhen enabled, instructs the Annex to ignore
the eighth bit of all received characters
on the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'imask-7bits'.
Note: This object is not valid for Synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.8 |
gpGenericCliImask7Defines whether input at the CLI is masked to
7 bits. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli-imask7'. The
default value for this object is enabled.
Note: This object is not valid for Synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.9 |
gpGenericBannerSpecifies whether the Annex banner and message-
of-the-day are displayed on the port. The
default is enabled.
This has four possible actions:
default, Y, yes, unset: banner before security,
motd after
none, N: no banner or motd
beforesec: banner and motd before
security
aftersec: banner and motd after
security
motd-before-sec: motd before security; no
banner
motd-after-sec: motd after security; no
banner
This MIB object corresponds to the NA/admin
asynchronous port parameter 'banner'.
Note: This object is not valid for Synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.10 |
gpGenericTcpKeepAliveThe default keep-alive value for connections
to this serial port. If this is zero, use the
value specified by anxTcpKeepAlive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tcp-keepalive'.
Note: This object is not valid for Synchronous ports.rw INTEGER .1.3.6.1.4.1.15.2.12.2.11 |
gpGenericDedicatedArgsCommand line arguments to be passed to process
started by a dedicated port with mode set to
'telnet', 'tn3270', 'rlogin', 'connect' (if LAT
is in use) or 'call'.
This object is not valid for TA ports.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'dedicated-arguments'.
Note: This object is not valid for Synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.12 |
gpGenericModemVarA string defining the type of modem attached
to the serial port.
This object is not valid for TA ports.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'type-of-modem'.
Note: This object is not valid for Synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.13 |
gpGenericDefSessModeThe default session mode when the DECServer command
interface is configured. The default is interactive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'default-session-mode'.
Note: This object is not valid for Synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.14 |
gpGenericResolveProtocolDefault host protocol to use when starting a
dedicated port and the protocol is not explicitly
specified in the command. Is set to one of
'telnet', connect, or any. Any means to try LAT
(connect) first and if that fails, try telnet.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'resolve-protocol.
Note: This object is not valid for Synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.15 |
gpSignalInputStartCharThe control character sequence that restarts
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'input-start-char'.
Note: This object is not valid for
synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.17 |
gpSignalInputStopCharThe control character sequence that stops
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'input-stop-char'.
Note: This object is not valid for
synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.18 |
gpSignalOutputStartCharThe control character sequence that restarts
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'output-start-char'.
Note: This object is not valid for
synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.19 |
gpSignalOutputStopCharThe control character sequence that stops
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'output-stop-char'.
Note: This object is not valid for
synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.20 |
gpSignalIxanyFlowCtrlThis parameter specifies whether any input
character will be treated as a start (xon)
character when output has been suspended by
a stop (xoff) character.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ixany-flow-control'.
Note: This object is not valid for
synchronous ports.rw Enumeration .1.3.6.1.4.1.15.2.12.2.21 |
gpSignalForwardKeyDefines a control character sequence as an
attention character to switch the user to
the next session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forward-key'.
Note: This object is not valid for
synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.23 |
gpSignalBackwardKeyDefines a control character sequence as an
attention character to switch the user to
the previous session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'Backward-key'.
Note: This object is not valid for Synchronous ports.rw DisplayString .1.3.6.1.4.1.15.2.12.2.24 |
gpLoginVciLoginPortPasswdEnables the port password if the port is
configured as a DECServer interface port.
The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'login-port-password'.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.30 |
gpLoginVciLoginTimeoutEnables a login timer if the port is configured
as a DECServer interface port. The default
is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'login-timeout'.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.31 |
gpTimerForwardTimerThis parameter defines the inter-character
timer that sets the amount of time, in tens of
milliseconds, that will elapse before
forwarding the received data. The value of
5 turns off the timer. Setting this object
to 0 causes the default value of 5 to be used.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forwarding-timer'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.32 |
gpTimerForwardCountSpecifies the number of received characters
buffered for the port by the Annex before
forwarding the characters to the host or
network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forwarding-count'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.33 |
gpTimerCliInactivityThe amount of time, in minutes, that the Annex
waits before hanging up the serial/ta port after
it becomes idle. A value of 0 turns off the
timer. A value of 255 means immediate, which
causes the Annex to hang up the port immediately
after exiting from the last job.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli-inactivity'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.34 |
gpTimerInactivityTimerThe amount of time, in minutes, which a port
can remain inactive before the Annex terminates
all sessions and resets the port. A value of
0 disables the timer.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'inactivity-timer'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.35 |
gpTimerInputIsActivityControls whether received input characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'input-is-activity'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.36 |
gpTimerOutputIsActivityControls whether transmitted output characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'output-is-activity'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.37 |
gpTimerResetIdleTimerDefines whether input or output resets the
idle timer for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'reset-idle-time-on'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.38 |
gpTimerLongBreakThis parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break greater than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'long-break'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.39 |
gpTimerShortBreakThis parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break shorter than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'short-break'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.40 |
gpSecurityUserNameA string defining the default user name for
the user of this serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'user-name'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.41 |
gpSecurityCliThis parameter controls whether security is
enabled for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli-security'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.42 |
gpSecurityConnectThis parameter controls whether the host-based
security policy is enabled for access from the
port to the network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'connect-security'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.43 |
gpSecurityPortServerThis parameter controls whether the host-based
security policy is enabled for access to the
port from the port server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'port-server-security'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.44 |
gpSecurityPortPasswdThis parameter defines a password for the
port for local password protection.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'port-password'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.45 |
gpSecurityIpsoClassDefines the IP security classification for
packets sent and received on this port. The
default value is none.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ipso-class'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.46 |
gpSecurityIpxControls whether IPX security is enabled on
this port. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ipx-security'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.47 |
gpLineEditAttnCharDefines a control character sequence as an
attention character to return the user to
the CLI prompt. The Annex-II only allows
x a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'attn-string'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.48 |
gpLineEditEchoThis parameter controls whether the Annex
echoes all characters as they are received
from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'echo'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.49 |
gpLineEditTelnetEscapeDefines the control character that returns the
user to the 'telnet:' prompt when running the
CLI telnet command.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
The value 'U' disables this feature on the
specified port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'telnet-escape'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.50 |
gpLineEditTelnetCRLFDefines what characters are transmitted
out the port to the network when the
End-of-Line character is sensed. 'enabled'
means transmit Line-Feed and Carriage-Return.
'disabled' means transmit Carriage-Return
and NULL. The default is enabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'telnet-crlf'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.51 |
gpLineEditMapToLowerWhen enabled, the Annex translates all upper
case characters to lower case as they are
received from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'map-to-lower'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.52 |
gpLineEditMapToUpperWhen enabled, the Annex translates all lower
case characters to upper case as they are
transmitted to the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'map-to-upper'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.53 |
gpLineEditCharEraseThis parameter controls whether the Annex
echoes the character erase and word erase
characters for a video terminal (enabled)
or for a hard-copy terminal (disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'char-erase'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.54 |
gpLineEditEraseCharDefines the character erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase-char'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.55 |
gpLineEditLineEraseThis parameter controls whether the Annex
echoes the line erase character for a video
terminal (enabled) or for a hard-copy terminal
(disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'line-erase'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.56 |
gpLineEditEraseLineDefines the line erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase-line'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.57 |
gpLineEditEraseWordDefines the word erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase-word'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.58 |
gpLineEditHardwareTabsWhen enabled, this parameter allows the Annex
to expand ASCII tab characters.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'hardware-tabs'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.59 |
gpLineEditRedisplayLineDefines the reprint line control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'redisplay-line'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.60 |
gpLineEditToggleOutputDefines the flush control character used to
flush the output buffer.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'toggle-output'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.61 |
gpLineEditNewLineTermThis parameter controls whether a carriage
return is echoed as just a carriage return
(enabled), or whether the carriage return is
echoed as a carriage return and line feed.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'newline-terminal'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.62 |
gpNetLocalAddrThe Internet address for the Annex's side
of the point-to-point (SLIP or PPP) link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'local-address'.rw IpAddress .1.3.6.1.4.1.15.2.12.2.63 |
gpNetRemoteAddrThe Internet address for the host at the
remote end of the point-to-point (SLIP or PPP)
link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'remote-address'.rwdeprecated IpAddress .1.3.6.1.4.1.15.2.12.2.64 |
gpNetPppDialupAddrlocal(1) - The annex will get the
PPP dialup addresses from the port
parameters local-address and remote-address.
acp(2) - The Annex requests the
PPP dialup addresses from the host-based
ACP.
dhcp(3) - The Annex requests the
PPP dialup addresses from the host-based
DHCP.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous global port
parameter 'address-origin'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.65 |
gpNetMetricThis parameter defines the hop count to
the remote end of the SLIP or PPP interface.
Setting this object to 0 defaults to a
value of 1.
This MIB object corresponds to the NA/admin
asynchronous, ta. synchronous port parameter
'metric'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.66 |
gpNetSlipSecureIf anxEnableSecurity is not set, this
parameter selects slip session logging. If
anxEnableSecurity is set, this parameter
permits slip access only from secure ports.
This MIB object corresponds to the NA/admin
asynchronous, ta and sync port parameter 'slip-ppp-security'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.67 |
gpNetInactivityThe number of units allowed for serial protocol
inactivity on the port. The type of unit, minutes
or seconds, is defined by the object
anxpNetInactivityUnits. If the type of units is
'seconds', the actual granularity is only 5
seconds. When the interval expires,
the port is automatically reset. A value of 0
disables the timer.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net-inactivity'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.68 |
gpNetDoCompressionWhen enabled, the Annex will attempt to negotiate
TCP/IP header compression on this serial link.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'do-compression'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.69 |
gpNetAllowCompressionWhen enabled, the Annex will allow TCP/IP
header compression on this serial link only
if the other end of the serial link initiates
the compression.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'allow-compression'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.70 |
gpNetInactivityUnitsThe type of units that are used for the
port's net inactivity timer. See also the
anxpNetInactivity object. The default value
is 'minutes'.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net-inactivity-units'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.71 |
gpSlipSubnetMaskThe subnet mask for this SLIP interface.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'subnet-mask'.rw IpAddress .1.3.6.1.4.1.15.2.12.2.72 |
gpSlipMtuSizeForce the compressed SLIP interface to use
a Maximum Transmission Unit (MTU) of either
1024 bytes (large) or 256 bytes (small). The
default is large.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'slip-mtu-size'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.73 |
gpSlipNoIcmpWhen enabled, the Annex will discard any
ICMP packets directed to this SLIP link.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'slip-no-icmp'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.74 |
gpSlipTosWhen enabled, the Annex sends interactive
traffic over this SLIP link before any other
traffic.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'slip-tos'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.75 |
gpPPPMruThis parameter defines the maximum receive
unit in bytes. The default value is 1500.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter 'ppp-mru'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.76 |
gpPPPAcmThis parameter specifies which of the first
32 bytes (0x00, ... 0x1F) can be sent as
clear text and which need to be escaped. A
bit on in the mask indicates the character
must be escaped. The mask should be specified
as an 8 hex character string (0x1F000000 and
1F000000 are both acceptable).
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp-acm'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.77 |
gpPPPSecurityProtoDefines which security protocol will be used
to authenticate the remote user. This
parameter must be set and the Annex
enable-security (anxEnableSecurity) must be
enabled before authentication is performed.
The default is none
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp-security-protocol'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.78 |
gpPPPRemoteUserThe username used by the Annex to identify
itself if the remote PPP peer asks for
authentication.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp-username-remote'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.79 |
gpPPPRemotePasswdThe password used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp-password-remote'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.80 |
gpPPPNcpA bitmask to set the PPP NCP Options:
0x0001 NCP-ALL
0x0002 NCP-IPCP
0x0004 NCP-ATCP
0x0008 NCP-IPXCP
0x0010 NCP-MP
0x0020 NCP-CCP
0x0040 NCP-CBCPrw INTEGER .1.3.6.1.4.1.15.2.12.2.81 |
gpPPPIpxNetworkThe IPX network number for an IPX PPP connection
using this port. When the IPX PPP connection is
established the network number will be negotiated.
If one end of the connection is set to zero then
the value from the other end of the connection will
be used.
The value of this object is an 8 digit hexadecimal
number string representing the IPX network segment
assigned to this port. The value must be unique
across the network domain.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp-ipx-network'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.82 |
gpPPPIpxNodeThe IPX node number for an IPX PPP connection
using this port.
The value of this object is a 12 digit
hexadecimal number string representing the IPX
node number assigned to this port.
Note the string is expected in the form:
12-3a-4-7-89-23.Each part of the address
must be a hex value separated by a hyphen.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp-ipx-node'.rw DisplayString .1.3.6.1.4.1.15.2.12.2.83 |
gpARAPGuestIf enabled, allows ARAP guest login service.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at-guest'.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.84 |
gpARAPNodeidThe default AppleTalk node ID hint that is
used by the Annex on this port. The address
consists of two parts separated by a dot. The
address may be in either hex or decimal format.
The first part is the network address and ranges from
0 to 65534 (0x0000 to 0xFFFE). The second part
is the node address and ranges from 0 to 254 (0x00
to 0xFE).
Example:
0x00BF.0xFD 191.253 0x00BF.253 191.0xFD
are all the same address.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at-nodeid'.rwdeprecated DisplayString .1.3.6.1.4.1.15.2.12.2.85 |
gpARAPSecurityControls whether ACP service is enabled for
this port when establishing an AppleTalk
connection.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at-security'.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.86 |
gpARAPV42BISControls whether V.42bis compression is done
during an ARAP session.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'arap-v42bis'.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.87 |
gpTN3270PrinterHostThe IP address of the machine running a
Berkeley-style lpd server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tn3270-printer-name'.rwdeprecated IpAddress .1.3.6.1.4.1.15.2.12.2.88 |
gpTN3270PrinterNameA valid printer name contained in the
/etc/printcap file on the remote host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tn3270-printer-name'.rwdeprecated DisplayString .1.3.6.1.4.1.15.2.12.2.89 |
gpLATAuthMapThis port parameter is functionally identical to
anxpLatAuthGroupVal and corresponds to the
NA/admin Annex parameter 'group-value'.
The syntax of this object is an octet string
32 bytes long, with the first byte
representing groups 0 through 7 and the last
byte representing groups 248 through 255.
For example, 0x40 0x25 ... means the groups
1,10,13,15 are valid for this port.
A returned value with all bits set to zero is the
same as setting 'group-value' to 'none'.
The object always returns a string 32 bytes long.
Note: You may use either this object or
anxpLatAuthVal object to read or set the
'group-value' parameter.anxpLatAuthMap is
preferred.rwdeprecated OCTET STRING .1.3.6.1.4.1.15.2.12.2.90 |
gpLATbEnableControls interpretation of LAT Data-B packets
received from host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'latb-enable'.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.91 |
gpLATMultiSessionThis parameter allows multisession operation to
be managed on a per port basis. If multisessions
for the server has not been enabled, any attempt
to use this command will cause the error message
'ETSMIN-786-Multisession feature Disabled' to be
displayed.
This MIB object corresponds to the NA/admin port
parameter 'multisessions'.
Note: * SNMP will not check for the Annex
MultiSession parameter.
* Setting this MIB object is equivalent to
defining the port parameter 'multisession'
through NA/admin.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.92 |
gpcharPortInFlowTypeThe port's type of input flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'hardware'
indicates flow control delegated to the lower level,
for example a parallel port.
'ctsRts' and 'dsrDtr' are specific to RS-232-like
ports. Although not architecturally pure, they are
included here for simplicity's sake.
Default is eia or hardware(3).rw Enumeration .1.3.6.1.4.1.15.2.12.2.94 |
gpcharPortOutFlowTypeThe port's type of output flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'hardware'
indicates flow control delegated to the lower level,
for example a parallel port.
'ctsRts' and 'dsrDtr' are specific to RS-232-like
ports. Although not architecturally pure, they are
included here for simplicy's sake.
Default is eia or hardware(3).rw Enumeration .1.3.6.1.4.1.15.2.12.2.95 |
gpcharPortSessionMaximumThe maximum number of concurrent sessions allowed
on the port. A value of -1 indicates no maximum.
Setting the maximum to less than the current
number of sessions has unspecified results.
Default is 3. This MIB object corresponds to NA/Admin
parameter 'max-session-count'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.96 |
gprs232AsyncPortBitsThe port's number of bits in a character. This object
corresponds to the admin parameter data-bitsrwdeprecated INTEGER .1.3.6.1.4.1.15.2.12.2.97 |
gprs232AsyncPortStopBitsThe port's number of stop bits. This object corresponds
to the admin parameter stop-bitsrwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.98 |
gprs232AsyncPortParityThe port's sense of a character parity bit.rwdeprecated Enumeration .1.3.6.1.4.1.15.2.12.2.99 |
gpV120MruThis parameter defines the maximum receive
unit in bytes. The default value is 256.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter 'v120-mru'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.101 |
gpMpMrruThis parameter sets the upper limit of
the MRRU LCP negotiation. All LCP
negotiations will start with this value;
negotiation downward only is allowed.
The default value is 1500.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter `mp-mrru'.rw INTEGER .1.3.6.1.4.1.15.2.12.2.102 |
gpMpEndPointClassThis parameter sets the preference for the
Endpoint Discriminator. PPP Magic Number
Block(5) isexcluded; it doesn't guarantee
unique link identities and could lead to
illegal bundle memebership.
The default is unitmacaddr(4).
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter `mp-endpoint-option'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.103 |
gpMpEndPointValueThis parameter sets the value of the
Endpoint Discriminator for options that
require user-configured information.
This parameter is only valid when
gpMPEndPointClass is set to Public Switched
Network Directory Number E.164 (6).
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter `mp-endpoint-address'.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.12.2.104 |
gpProxyArpEnableSpecifies whether the Annex will proxy
ARP all remote IP connections. A value
of enabled(1) will allow the Annex to proxy
all remote IP connections. A value of
disabled(2) allows the Annex to proxy only
remote IP connections having the same
subnet address as the Annex.
This MIB object corresponds to the
NA/admin global port parameter
'proxy-arp-enabled'.rw Enumeration .1.3.6.1.4.1.15.2.12.2.105 |
gpPPPTraceLevelControls whether PPP trace messages are sent to the
syslog facility or not. The default value is none(0).
This MIB object corresponds to the na/admin port parameter
ppp-trace-level.rw Enumeration .1.3.6.1.4.1.15.2.12.2.106 |
anxTunnelTableTable of tunnel entries. SEQUENCE OF AnxTunnelEntry .1.3.6.1.4.1.15.2.14.1 |
anxTunnelEntryA UDAS Tunnel entry. AnxTunnelEntry .1.3.6.1.4.1.15.2.14.1.1 |
anxTunnelLineIndexThe index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213). This is unused for
the ra2000, ra4000 platforms but needs to be
filled in with a 1.
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
modulero INTEGER (1..'7fffffff'h) -- Change `7fffffff'h to .1.3.6.1.4.1.15.2.14.1.1.1 |
anxTunnelUnitIndexOn a PRI interface, this is a call's B channel number ranging
from 1 to anxt1TotChan. On a port interface, this
is the port number ranging from 1 to ports.totalports.ro INTEGER .1.3.6.1.4.1.15.2.14.1.1.2 |
anxTunnelWanProtocolThis field describes the protocol used
on the WAN interface from the Gateway
(or Home Agent) to the customer premise
equipment (CPE).ro Enumeration .1.3.6.1.4.1.15.2.14.1.1.3 |
anxTunnelWanAddressThis field describes the WAN Address from the
Gateway (or Home Agent) to the customer
premise equipment (CPE).ro OCTET STRING .1.3.6.1.4.1.15.2.14.1.1.4 |
anxTunnelStateThis fields describes the Tunnel's
current state.
reserved - visitor added,
authentication in progress
pending - authentication complete,
registration requisition has been sent
to gateway, tunnel not registered yet
registered - tunnel is upro Enumeration .1.3.6.1.4.1.15.2.14.1.1.5 |
anxTunnelMnIPAddressThe IP Address of the Remote Node.ro IpAddress .1.3.6.1.4.1.15.2.14.1.1.6 |
anxTunnelMnIPXAddressThe IPX Address of the Remote Node.ro DisplayString .1.3.6.1.4.1.15.2.14.1.1.7 |
anxTunnelHaAddressThe IP Address assigned to the Home Agent.ro IpAddress .1.3.6.1.4.1.15.2.14.1.1.8 |
nfasPref1SigGatewayThe IP address of the primary nfas gateway.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref1-sig-gateway'.rw IpAddress .1.3.6.1.4.1.15.2.111.1 |
nfasPref2SigGatewayThe IP address of the backup nfas gateway.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref2-sig-gateway'.rw IpAddress .1.3.6.1.4.1.15.2.111.2 |
nfasPref1SigPortThe TCP port number used on the primary nfas gateway.
This MIB object corresponds to the NA/admin parameter
'pref1-sig-port'.rw INTEGER .1.3.6.1.4.1.15.2.111.3 |
nfasPref2SigPortThe TCP port number used on the nfas backup gateway.
This MIB object corresponds to the NA/admin parameter
'pref2-sig-port'.rw INTEGER .1.3.6.1.4.1.15.2.111.4 |
nfasGroupNameThis is a trap to indicate the nfas group name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.111.5 |
nfasDchannelstateThis will indicate whether this interface is
Active or Inactive : 1-Active, 2-Inactive.ro INTEGER .1.3.6.1.4.1.15.2.111.6 |
nfasConnectionTableTable of nfas connection information. SEQUENCE OF NfasConnectionEntry .1.3.6.1.4.1.15.2.111.7 |
nfasConnectionEntryThe nfas connection information. NfasConnectionEntry .1.3.6.1.4.1.15.2.111.7.1 |
nfasInterfaceStatusThe type of interface - Primary,Backup or Bearer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.111.7.1.1 |
nfasIpAddressThe IP Address of the Interface.ro IpAddress .1.3.6.1.4.1.15.2.111.7.1.2 |
nfasDchannelStatusThe D Channel Status - Active or Inactive.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.111.7.1.3 |
nfasConnectStatusThe nfas connect status - Connected or Disconnected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.111.7.1.4 |
nfasInterfaceNoThe nfas interface number which could be beween 0-19.
The Interface No for the primary is always 0.ro INTEGER .1.3.6.1.4.1.15.2.111.7.1.5 |
nfasConnectionStatusThis is a trap to indicate the nfas connection status
between Primary,Backup and Bearer .ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.111.8 |
nfasBackupStatusThis is a trap to indicate the nfas switch-over status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15.2.111.9 |
ss7Pref1SigGatewayThe IP address of the primary SS7 gateway.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref1-sig-gateway'.rw IpAddress .1.3.6.1.4.1.4618.1.2.2.1.1 |
ss7Pref2SigGatewayThe IP address of the primary secondary SS7 gateway.
This may be zero if a redundant SS7 gateway is not
available.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref2-sig-gateway'.rw IpAddress .1.3.6.1.4.1.4618.1.2.2.1.2 |
ss7Pref1SigPortThe TCP port number used on the primary SS7 gateway.
The default is 1000.
This MIB object corresponds to the NA/admin parameter
'pref1-sig-port'.rw INTEGER .1.3.6.1.4.1.4618.1.2.2.1.3 |
ss7Pref2SigPortThe TCP port number used on the secondary SS7 gateway.
The default is 1000. This entry is zero if no redundant
SS7 gateway is available.
This MIB object corresponds to the NA/admin parameter
'pref2-sig-port'.rw INTEGER .1.3.6.1.4.1.4618.1.2.2.1.4 |
ss7SigKeepaliveThe maximum time to wait for a packet to be received from
SS7 server. This value is in seconds. The default value is
15 seconds.
This MIB object corresponds to the NA/admin parameter
'sig-keepalive'.rw INTEGER .1.3.6.1.4.1.4618.1.2.2.1.5 |
ss7CurrentGatewayThe address of the current SS7 server. This can
change dynamically depending on the state of the
server.ro IpAddress .1.3.6.1.4.1.4618.1.2.2.1.6 |
ss7ConnectionTimeTime at which this connection was established
to the current SS7 Gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4618.1.2.2.1.7 |
ss7RegistrationDescribes whether the RAS can accept and/or receive
calls. This is set by the ss7 gateway.ro Enumeration .1.3.6.1.4.1.4618.1.2.2.1.8 |
ss7ChanTableTable of ss7 Channel information. SEQUENCE OF Ss7ChanEntry .1.3.6.1.4.1.4618.1.2.2.1.9 |
ss7ChanEntryThe ss7 channel information. Ss7ChanEntry .1.3.6.1.4.1.4618.1.2.2.1.9.1 |
ss7WanIndexThe index value which uniquely identifies the
Wan Module.ro INTEGER .1.3.6.1.4.1.4618.1.2.2.1.9.1.1 |
ss7ChanNumberThe index value which uniquely identifies the
Channel Numnber.ro INTEGER .1.3.6.1.4.1.4618.1.2.2.1.9.1.2 |
ss7ChanStatusThe status of the ds0 channel.
idle(1) - the DS0 is available for calls
busy(2) - call is in progress
blocked(3) - the RAS of the gateway requested block
unblocking(4) -
loopback(5) - loopback requested by the gateway
restarting(6) - DS0 restart requested by the gateway
continuityTest(7) - the RAS or the gateway requested continuity testro Enumeration .1.3.6.1.4.1.4618.1.2.2.1.9.1.3 |
ss7ChanStateThe state of the ds0 channel.
idle(1) - no call in progress
connected(2) - call fully established.
waitReleaseComplete(3) - waiting for Release Complete
from gateway.
waitATConnect(4) - waiting for connect from WAN
manager.
waitRelease(5) - waiting for Release from gateway.
waitConnect(6) - waiting for connect from gateway.ro Enumeration .1.3.6.1.4.1.4618.1.2.2.1.9.1.4 |