Home/Catalog/WDMYCLOUDEX4-MIB

WDMYCLOUDEX4-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

44
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

44 total
Object Name
wd
OBJECT IDENTIFIER
.1.3.6.1.4.1.5127
SNMPv2-SMI
Unknown
.1.3.6.1.4.1.5127
RFC-1212
NOTIFICATION-TYPE
.1.3.6.1.4.1.5127
productID
OBJECT IDENTIFIER
.1.3.6.1.4.1.5127.1
projectID
OBJECT IDENTIFIER
.1.3.6.1.4.1.5127.1.1
modelID
OBJECT IDENTIFIER
.1.3.6.1.4.1.5127.1.1.1
submodelID
OBJECT IDENTIFIER
.1.3.6.1.4.1.5127.1.1.1.1
nasAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.5127.1.1.1.1.1
wdmycloudex4AgentVerVersion information for the agent of SNMP of WDMYCLOUDEX4.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.1
wdmycloudex4SoftwareVersionThe device software version.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.2
wdmycloudex4HostNameThe device host name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.3
wdmycloudex4FTPServerFtp Server status. 1 : enable 0 : disablero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.5
wdmycloudex4NetTypeThe Network type. 0 : Workgroup 1 : Active Directoryro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.6
wdmycloudex4TemperatureThe temperature of the system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.7
wdmycloudex4FanStatusThe status of the fan0 & fan1.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.8
wdmycloudex4VolumeTableA table of active volumes on the NAS device.
SEQUENCE OF Wdmycloudex4VolumeEntry
.1.3.6.1.4.1.5127.1.1.1.1.1.9
wdmycloudex4VolumeEntryAn entry in the volume table.
Wdmycloudex4VolumeEntry
.1.3.6.1.4.1.5127.1.1.1.1.1.9.1
wdmycloudex4VolumeNumInstance number of the volume entry.ro
Integer32
.1.3.6.1.4.1.5127.1.1.1.1.1.9.1.1
wdmycloudex4VolumeNameThe name of the volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.9.1.2
wdmycloudex4VolumeFsTypeThe type of file system of the volume. Example : ext3 or ext4ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.9.1.3
wdmycloudex4VolumeRaidLevelThe RAID level of the volume. (STANDARD LINEAR RAID0 RAID1 RAID5 RAID10 RAID5+SPARE)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.9.1.4
wdmycloudex4VolumeSizeThe size of the volume in bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.9.1.5
wdmycloudex4VolumeFreeSpaceFree space on the volume in bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.9.1.6
wdmycloudex4DiskTableA table of physical disks attached to the NAS device.
SEQUENCE OF Wdmycloudex4DiskEntry
.1.3.6.1.4.1.5127.1.1.1.1.1.10
wdmycloudex4DiskEntryAn entry in the physical disk table.
Wdmycloudex4DiskEntry
.1.3.6.1.4.1.5127.1.1.1.1.1.10.1
wdmycloudex4DiskNumInstance number of the disk entry.ro
Integer32
.1.3.6.1.4.1.5127.1.1.1.1.1.10.1.1
wdmycloudex4DiskVendorThe vendor of the disk drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.10.1.2
wdmycloudex4DiskModelThe disk drive's model name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.10.1.3
wdmycloudex4DiskSerialNumberThe disk drive's serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.10.1.4
wdmycloudex4DiskTemperatureThe centigrade temperature of this disk.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.10.1.5
wdmycloudex4DiskCapacityThe capacity of the disk in GB.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.10.1.6
wdmycloudex4UPSTableA table of UPS attached to the NAS device.
SEQUENCE OF Wdmycloudex4UPSEntry
.1.3.6.1.4.1.5127.1.1.1.1.1.11
wdmycloudex4UPSEntryAn entry in the UPS table.
Wdmycloudex4UPSEntry
.1.3.6.1.4.1.5127.1.1.1.1.1.11.1
wdmycloudex4UPSNumInstance number of the UPS entry.ro
Integer32
.1.3.6.1.4.1.5127.1.1.1.1.1.11.1.1
wdmycloudex4UPSModeThe mode of the UPSro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.11.1.2
wdmycloudex4UPSManufacturerThe manufacturer of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.11.1.3
wdmycloudex4UPSProductThe product name of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.11.1.4
wdmycloudex4UPSBatteryChargeThe battery charge of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.11.1.5
wdmycloudex4UPSStatusThe status of this UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.5127.1.1.1.1.1.11.1.6
notifyEvts
OBJECT IDENTIFIER
.1.3.6.1.4.1.5127.1.1.1.1.1.200
notifyPasswdChangedAn indication that the Administrator's password has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5127.1.1.1.1.1.200.1
notifyFirmwareUpgradedAn indication that firmware has been upgraded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5127.1.1.1.1.1.200.2
notifyNetworkChangedAn indication that the network settings has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5127.1.1.1.1.1.200.3
notifyTemperatureExceededAn indication that system temperature has exceeded.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5127.1.1.1.1.1.200.4
WDMYCLOUDEX4-MIB - SNMP MIB Reference | MIBs Explorer