WBSN-APPLIANCE-MIB
AI MIB Summary
The WBSN-APPLIANCE-MIB module provides SNMP access to monitor and manage Websense (now Forcepoint) Web Security Appliance performance, security events, and traffic statistics. It exposes critical operational metrics including web filtering policy enforcement counts, blocked request volumes, cache utilization, system resource usage, and appliance health status for centralized network monitoring.
Websense Appliance SNMP
Main OID:
websense.1.3.6.1.4.1.23365
98
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
98 total| Object Name |
|---|
websenseWebsense Appliance SNMP MODULE-IDENTITY .1.3.6.1.4.1.23365 |
appliance OBJECT IDENTIFIER .1.3.6.1.4.1.23365.10000 |
testEventWebsense Alert: this event is for testing use NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.10 |
cpuMaxUsageExceedWebsense Alert: high CPU usage NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1000 |
memMaxUsageExceedWebsense Alert: high memory usage NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1001 |
networkMaxBandwidthExceedWebsense Alert: heavy network traffic on interface NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1002 |
diskFreeMinSizeExceedWebsense Alert: low free disk space NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1003 |
swapMinFreeExceedWebsense Alert: low free swap space NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1004 |
systemLoadWebsense Alert: heavy system load NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1005 |
logFileMaxSizeExceedWebsense Alert: too large log file size NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1006 |
logCacheMinFreeExceedWebsense Alert: low free log cache space NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1007 |
moduleDownWebsense Alert: appliance module down NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1050 |
serviceDownWebsense Alert: appliance service down NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1051 |
backupFailureWebsense Alert: appliance backup failure NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1052 |
logServerConnectionLostWebsense Alert: log server connection lost NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1053 |
hostnameChangeWebsense Alert: appliance hostname changed NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1061 |
ipAddressChangeWebsense Alert: appliance IP address changed NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.1062 |
powerSupplyWebsense Alert: appliance power supply warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2001 |
redundancyWebsense Alert: appliance redundancy warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2002 |
tempsWebsense Alert: appliance temperatures warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2003 |
fansWebsense Alert: appliance fans warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2004 |
voltWebsense Alert: appliance voltages warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2005 |
logsWebsense Alert: appliance logs warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2006 |
memWebsense Alert: appliance memory warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2007 |
intrusionWebsense Alert: appliance chassis intrusion detected NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2008 |
batteryWebsense Alert: appliance battery warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2009 |
raidWebsense Alert: appliance RAID controller warning NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.0.2010 |
moduleNameThe name of current module: Appliance Controller, Websense Content Gateway, Websense Web Security, Network Agent, Websense Email Security Gatewayro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.1 |
memUsageFlagThe flag to indicate memory usage exceedro INTEGER .1.3.6.1.4.1.23365.10000.2 |
vmTableA list of virtual machines. SEQUENCE OF VmEntry .1.3.6.1.4.1.23365.10000.3 |
vmEntryA concept row of virtual machine table. VmEntry .1.3.6.1.4.1.23365.10000.3.1 |
vmStatusThe status of virtual machine.ro Enumeration .1.3.6.1.4.1.23365.10000.3.1.1 |
vmNameThe name of virtual machine.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.3.1.2 |
hostname OBJECT IDENTIFIER .1.3.6.1.4.1.23365.10000.4 |
hostnameChangeFlagThe flag to indicate hostname change.ro INTEGER .1.3.6.1.4.1.23365.10000.4.1 |
prevHostnameThe hostname before changed.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.4.2 |
currHostnameThe current hostname.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.4.3 |
ifaTableA list of monitoring interface IP addresses. SEQUENCE OF IfaEntry .1.3.6.1.4.1.23365.10000.5 |
ifaEntryA concept row of monitoring interface IP address table. IfaEntry .1.3.6.1.4.1.23365.10000.5.1 |
ifaChangeFlagThe flag to indicate whether the IP address of monitoring interface has been changed.ro INTEGER .1.3.6.1.4.1.23365.10000.5.1.1 |
ifaNameThe name of monitoring interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.5.1.2 |
ifaPrevAddressThe previous IP address of monitoring interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.5.1.3 |
ifaCurrAddressThe current IP address of monitoring interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.5.1.4 |
ifaSpeedThe speed of monitoring interface.ro INTEGER .1.3.6.1.4.1.23365.10000.5.1.5 |
ifaInboundExceedFlagThe flag to indicate whether the inbound network traffic of monitoring interface exceeds its threhold.ro INTEGER .1.3.6.1.4.1.23365.10000.5.1.6 |
ifaOutboundExceedFlagThe flag to indicate whether the outbound network traffic of monitoring interface exceeds its threhold.ro INTEGER .1.3.6.1.4.1.23365.10000.5.1.7 |
ifaPhysAddressThe physical address of monitoring interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.5.1.8 |
ifaChangeFlagv6The flag to indicate whether the IPv6 address of monitoring interface has been changed.ro INTEGER .1.3.6.1.4.1.23365.10000.5.1.9 |
ifaPrevAddressv6The previous IPv6 address of monitoring interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.5.1.10 |
ifaCurrAddressv6The current IPv6 address of monitoring interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.5.1.11 |
raidStatus OBJECT IDENTIFIER .1.3.6.1.4.1.23365.10000.6 |
raidErrorFlagThe flag is set when disk error is detected.ro INTEGER .1.3.6.1.4.1.23365.10000.6.1 |
dskPhysicalNrThe number of physical disks in the RAID controller.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.6.2 |
dskCriticalNrThe number of physical disks in critical state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.6.3 |
dskFailedNrThe number of physical disks in failed state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.6.4 |
dskPhysErrMsgThe error message to describe the abnormal state of physical disks.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.6.5 |
dskVirtualNrThe number of virtual drives in the RAID controller.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.6.6 |
dskDegradedNrThe number of degraded virtual drives.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.6.7 |
dskOfflineNrThe number of offline virtual drives.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.6.8 |
svcTableA list of service entries. SEQUENCE OF SvcEntry .1.3.6.1.4.1.23365.10000.7 |
svcEntryA concept row of service table. SvcEntry .1.3.6.1.4.1.23365.10000.7.1 |
svcStatusThe status of service.ro Enumeration .1.3.6.1.4.1.23365.10000.7.1.1 |
svcNameThe name of service.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.7.1.2 |
loadAvg OBJECT IDENTIFIER .1.3.6.1.4.1.23365.10000.8 |
loadErrorFlagThe flag is set when load average limit is met.ro INTEGER .1.3.6.1.4.1.23365.10000.8.1 |
loadNameThe load name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.8.2 |
loadErrorMessageThe message to describe current load error.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.8.3 |
wsAlert OBJECT IDENTIFIER .1.3.6.1.4.1.23365.10000.9 |
wsAlertMessageThe detailed message to describe current alert.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.9.1 |
evtInfo OBJECT IDENTIFIER .1.3.6.1.4.1.23365.10000.10 |
evtTimestampTimestamp when current event occurredro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.10.1 |
evtDirThe direction of the eventro Enumeration .1.3.6.1.4.1.23365.10000.10.2 |
evtSensorThe name of sensor: Power Supply, Temperature, Fan, Voltage, System ACPI Power State, Event Logging Disabled, Physical Security (Chassis Intrusion), Batteryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.10.3 |
evtDescThe name of current eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.10.4 |
triggerReadingThe trigger reading of sensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.10.5 |
triggerThresholdThe threshold to trigger this eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23365.10000.10.6 |
errorClear OBJECT IDENTIFIER .1.3.6.1.4.1.23365.10000.10000 |
cpuMaxUsageExceedClearWebsense Alert: 'high CPU usage' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1000 |
memMaxUsageExceedClearWebsense Alert: 'high memory usage' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1001 |
networkMaxBandwidthExceedClearWebsense Alert: 'heavy network traffic on interface' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1002 |
diskFreeMinSizeExceedClearWebsense Alert: 'low free disk space' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1003 |
swapMinFreeExceedClearWebsense Alert: 'low free swap space' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1004 |
systemLoadClearWebsense Alert: 'heavy system load' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1005 |
logFileMaxSizeExceedClearWebsense Alert: 'too large log file size' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1006 |
logCacheMinFreeExceedClearWebsense Alert: 'low free log cache space' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1007 |
moduleDownClearWebsense Alert: 'appliance module down' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1050 |
serviceDownClearWebsense Alert: 'appliance service down' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1051 |
logServerConnectionLostClearWebsense Alert: 'log server connection lost' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.1053 |
powerSupplyClearWebsense Alert: 'appliance power supply warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2001 |
redundancyClearWebsense Alert: 'appliance redundancy warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2002 |
tempsClearWebsense Alert: 'appliance temperatures warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2003 |
fansClearWebsense Alert: 'appliance fans warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2004 |
voltClearWebsense Alert: 'appliance voltages warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2005 |
logsClearWebsense Alert: 'appliance logs warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2006 |
memClearWebsense Alert: 'appliance memory warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2007 |
intrusionClearWebsense Alert: 'appliance chassis intrusion detected' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2008 |
batteryClearWebsense Alert: 'appliance battery warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2009 |
raidClearWebsense Alert: 'appliance RAID controller warning' is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.23365.10000.10000.0.2010 |