Home/Catalog/WBSN-APPLIANCE-MIB

WBSN-APPLIANCE-MIB

AI MIB Summary

The WBSN-APPLIANCE-MIB module provides SNMP access to monitor and manage Websense (now Forcepoint) Web Security Appliance performance, security events, and traffic statistics. It exposes critical operational metrics including web filtering policy enforcement counts, blocked request volumes, cache utilization, system resource usage, and appliance health status for centralized network monitoring.

Websense Appliance SNMP
Main OID:
websense.1.3.6.1.4.1.23365
98
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

98 total
Object Name
websenseWebsense Appliance SNMP
MODULE-IDENTITY
.1.3.6.1.4.1.23365
appliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.23365.10000
testEventWebsense Alert: this event is for testing use
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.10
cpuMaxUsageExceedWebsense Alert: high CPU usage
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1000
memMaxUsageExceedWebsense Alert: high memory usage
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1001
networkMaxBandwidthExceedWebsense Alert: heavy network traffic on interface
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1002
diskFreeMinSizeExceedWebsense Alert: low free disk space
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1003
swapMinFreeExceedWebsense Alert: low free swap space
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1004
systemLoadWebsense Alert: heavy system load
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1005
logFileMaxSizeExceedWebsense Alert: too large log file size
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1006
logCacheMinFreeExceedWebsense Alert: low free log cache space
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1007
moduleDownWebsense Alert: appliance module down
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1050
serviceDownWebsense Alert: appliance service down
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1051
backupFailureWebsense Alert: appliance backup failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1052
logServerConnectionLostWebsense Alert: log server connection lost
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1053
hostnameChangeWebsense Alert: appliance hostname changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1061
ipAddressChangeWebsense Alert: appliance IP address changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.1062
powerSupplyWebsense Alert: appliance power supply warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2001
redundancyWebsense Alert: appliance redundancy warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2002
tempsWebsense Alert: appliance temperatures warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2003
fansWebsense Alert: appliance fans warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2004
voltWebsense Alert: appliance voltages warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2005
logsWebsense Alert: appliance logs warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2006
memWebsense Alert: appliance memory warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2007
intrusionWebsense Alert: appliance chassis intrusion detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2008
batteryWebsense Alert: appliance battery warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2009
raidWebsense Alert: appliance RAID controller warning
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.0.2010
moduleNameThe name of current module: Appliance Controller, Websense Content Gateway, Websense Web Security, Network Agent, Websense Email Security Gatewayro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.1
memUsageFlagThe flag to indicate memory usage exceedro
INTEGER
.1.3.6.1.4.1.23365.10000.2
vmTableA list of virtual machines.
SEQUENCE OF VmEntry
.1.3.6.1.4.1.23365.10000.3
vmEntryA concept row of virtual machine table.
VmEntry
.1.3.6.1.4.1.23365.10000.3.1
vmStatusThe status of virtual machine.ro
Enumeration
.1.3.6.1.4.1.23365.10000.3.1.1
vmNameThe name of virtual machine.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.3.1.2
hostname
OBJECT IDENTIFIER
.1.3.6.1.4.1.23365.10000.4
hostnameChangeFlagThe flag to indicate hostname change.ro
INTEGER
.1.3.6.1.4.1.23365.10000.4.1
prevHostnameThe hostname before changed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.4.2
currHostnameThe current hostname.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.4.3
ifaTableA list of monitoring interface IP addresses.
SEQUENCE OF IfaEntry
.1.3.6.1.4.1.23365.10000.5
ifaEntryA concept row of monitoring interface IP address table.
IfaEntry
.1.3.6.1.4.1.23365.10000.5.1
ifaChangeFlagThe flag to indicate whether the IP address of monitoring interface has been changed.ro
INTEGER
.1.3.6.1.4.1.23365.10000.5.1.1
ifaNameThe name of monitoring interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.5.1.2
ifaPrevAddressThe previous IP address of monitoring interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.5.1.3
ifaCurrAddressThe current IP address of monitoring interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.5.1.4
ifaSpeedThe speed of monitoring interface.ro
INTEGER
.1.3.6.1.4.1.23365.10000.5.1.5
ifaInboundExceedFlagThe flag to indicate whether the inbound network traffic of monitoring interface exceeds its threhold.ro
INTEGER
.1.3.6.1.4.1.23365.10000.5.1.6
ifaOutboundExceedFlagThe flag to indicate whether the outbound network traffic of monitoring interface exceeds its threhold.ro
INTEGER
.1.3.6.1.4.1.23365.10000.5.1.7
ifaPhysAddressThe physical address of monitoring interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.5.1.8
ifaChangeFlagv6The flag to indicate whether the IPv6 address of monitoring interface has been changed.ro
INTEGER
.1.3.6.1.4.1.23365.10000.5.1.9
ifaPrevAddressv6The previous IPv6 address of monitoring interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.5.1.10
ifaCurrAddressv6The current IPv6 address of monitoring interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.5.1.11
raidStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.23365.10000.6
raidErrorFlagThe flag is set when disk error is detected.ro
INTEGER
.1.3.6.1.4.1.23365.10000.6.1
dskPhysicalNrThe number of physical disks in the RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.6.2
dskCriticalNrThe number of physical disks in critical state.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.6.3
dskFailedNrThe number of physical disks in failed state.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.6.4
dskPhysErrMsgThe error message to describe the abnormal state of physical disks.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.6.5
dskVirtualNrThe number of virtual drives in the RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.6.6
dskDegradedNrThe number of degraded virtual drives.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.6.7
dskOfflineNrThe number of offline virtual drives.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.6.8
svcTableA list of service entries.
SEQUENCE OF SvcEntry
.1.3.6.1.4.1.23365.10000.7
svcEntryA concept row of service table.
SvcEntry
.1.3.6.1.4.1.23365.10000.7.1
svcStatusThe status of service.ro
Enumeration
.1.3.6.1.4.1.23365.10000.7.1.1
svcNameThe name of service.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.7.1.2
loadAvg
OBJECT IDENTIFIER
.1.3.6.1.4.1.23365.10000.8
loadErrorFlagThe flag is set when load average limit is met.ro
INTEGER
.1.3.6.1.4.1.23365.10000.8.1
loadNameThe load name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.8.2
loadErrorMessageThe message to describe current load error.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.8.3
wsAlert
OBJECT IDENTIFIER
.1.3.6.1.4.1.23365.10000.9
wsAlertMessageThe detailed message to describe current alert.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.9.1
evtInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.23365.10000.10
evtTimestampTimestamp when current event occurredro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.10.1
evtDirThe direction of the eventro
Enumeration
.1.3.6.1.4.1.23365.10000.10.2
evtSensorThe name of sensor: Power Supply, Temperature, Fan, Voltage, System ACPI Power State, Event Logging Disabled, Physical Security (Chassis Intrusion), Batteryro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.10.3
evtDescThe name of current eventro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.10.4
triggerReadingThe trigger reading of sensorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.10.5
triggerThresholdThe threshold to trigger this eventro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23365.10000.10.6
errorClear
OBJECT IDENTIFIER
.1.3.6.1.4.1.23365.10000.10000
cpuMaxUsageExceedClearWebsense Alert: 'high CPU usage' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1000
memMaxUsageExceedClearWebsense Alert: 'high memory usage' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1001
networkMaxBandwidthExceedClearWebsense Alert: 'heavy network traffic on interface' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1002
diskFreeMinSizeExceedClearWebsense Alert: 'low free disk space' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1003
swapMinFreeExceedClearWebsense Alert: 'low free swap space' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1004
systemLoadClearWebsense Alert: 'heavy system load' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1005
logFileMaxSizeExceedClearWebsense Alert: 'too large log file size' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1006
logCacheMinFreeExceedClearWebsense Alert: 'low free log cache space' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1007
moduleDownClearWebsense Alert: 'appliance module down' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1050
serviceDownClearWebsense Alert: 'appliance service down' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1051
logServerConnectionLostClearWebsense Alert: 'log server connection lost' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.1053
powerSupplyClearWebsense Alert: 'appliance power supply warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2001
redundancyClearWebsense Alert: 'appliance redundancy warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2002
tempsClearWebsense Alert: 'appliance temperatures warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2003
fansClearWebsense Alert: 'appliance fans warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2004
voltClearWebsense Alert: 'appliance voltages warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2005
logsClearWebsense Alert: 'appliance logs warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2006
memClearWebsense Alert: 'appliance memory warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2007
intrusionClearWebsense Alert: 'appliance chassis intrusion detected' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2008
batteryClearWebsense Alert: 'appliance battery warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2009
raidClearWebsense Alert: 'appliance RAID controller warning' is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.23365.10000.10000.0.2010
WBSN-APPLIANCE-MIB - SNMP MIB Reference | MIBs Explorer