Home/Catalog/USHA-MIB

USHA-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for USHA-MIB.

278
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

278 total
Object Name
ingrasys
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468
RFC1155-SMI
Unknown
.1.3.6.1.4.1.2468
product
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1
upsAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2
ushap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1
upsObjectGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1
upsIdentGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.1
upsIdentGroupManufacturerThe name of the UPS manufacturer.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.1.1
upsIdentGroupModelThe UPS Model designation.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.1.2
upsIdentGroupUPSFirmwareVersionThe UPS firmware/software version(s). This variable may or may not have the same value as upsIdentGroupAgentSoftwareVersion in some implementations.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.1.3
upsIdentGroupAgentSoftwareVersionThe USHA software/firmware version. This variable may or may not have the same value as upsIdentGroupUPSSoftwareVersion in some implementations.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.1.4
upsIdentGroupNameA string identifying the UPS. This object should be set by the administrator.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.1.5
upsIdentGroupAttachedDevicesA string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.1.6
upsIdentGroupUpsSerialNumberThe UPS serial no.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.1.7
upsBatteryGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.2
upsBatteryGroupStatusThe indication of the status in the UPS system's batteries.ro
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.2.1
upsBatteryGroupSecondsOnBatteryIf the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. 0 shall be returned if the unit is not on battery power.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.2.2
upsBatteryGroupEstimatedMinutesRemainingAn estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.2.3
upsBatteryGroupEstimatedChargeRemainingAn estimate of the battery charge remaining expressed as a percent of full charge.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.2.4
upsBatteryGroupVoltageThe magnitude of the present battery voltage in 0.1 Volt DC.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.2.5
upsBatteryGroupMandatoryThe present battery mandatory.ro
INTEGER -- "0.1 Amp DC"
.1.3.6.1.4.1.2468.1.2.1.1.2.6
upsBatteryGroupTemperatureThe ambient temperature at or near the UPS Battery casing.ro
INTEGER -- "degrees 0.1 Centigrade"
.1.3.6.1.4.1.2468.1.2.1.1.2.7
upsInputGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.3
upsInputGroupLineBadsA count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.ro
Counter
.1.3.6.1.4.1.2468.1.2.1.1.3.1
upsInputGroupNumLinesThe number of input lines utilized in this device. This variable indicates the number of rows in the input table.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.3.2
upsInputGroupTableA list of input table entries. The number of entries is given by the value of upsInputGroupNumLines.
SEQUENCE OF UpsInputGroupEntry
.1.3.6.1.4.1.2468.1.2.1.1.3.3
upsInputGroupEntryAn entry containing information applicable to a particular input line.
UpsInputGroupEntry
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1
upsInputGroupLineIndexThe index of UpsInputGroupEntry.ro
PositiveInteger
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.1
upsInputGroupFrequencyThe present input frequency.ro
NonNegativeInteger -- "0.1 Hertz"
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.2
upsInputGroupVoltageThe input utility line voltage in 0.1 volts.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.3
upsInputGroupCurrentThe magnitude of the present input current in 0.1 A.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.4
upsInputGroupTruePowerThe magnitude of the present input true power.ro
NonNegativeInteger -- "Watts"
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.5
upsInputGroupVoltageMaxThe maximum utility line voltage in 0.1 VAC for last 1 minute.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.6
upsInputGroupVoltageMinThe minimum utility line voltage in 0.1 VAC for last 1 minute.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.7
upsOutputGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.4
upsOutputGroupSourceThe present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.ro
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.4.1
upsOutputGroupFrequencyThe current output frequency of the UPS system in 0.1 of HZ.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.4.2
upsOutputGroupNumLinesThe number of output lines utilized in this device. This variable indicates the number of rows in the output table.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.4.3
upsOutputGroupTableA list of output table entries. The number of entries is given by the value of upsOutputGroupNumLines.
SEQUENCE OF UpsOutputGroupEntry
.1.3.6.1.4.1.2468.1.2.1.1.4.4
upsOutputGroupEntryAn entry containing information applicable to a particular output line.
UpsOutputGroupEntry
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1
upsOutputGroupLineIndexThe output line identifier.ro
PositiveInteger
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.1
upsOutputGroupVoltageThe output voltage of the UPS system in 0.1 volts.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.2
upsOutputGroupCurrentThe output current of the UPS system in 0.1 Amps.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.3
upsOutputGroupPowerThe present output true power.ro
NonNegativeInteger -- "Watts"
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.4
upsOutputGroupPercentLoadThe percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.5
upsBypassGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.5
upsBypassGroupFrequencyThe present bypass frequency.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.5.1
upsBypassGroupNumLinesThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.5.2
upsBypassGroupTableA list of bypass table entries. The number of entries is given by the value of upsBypassGroupNumLines.
SEQUENCE OF UpsBypassGroupEntry
.1.3.6.1.4.1.2468.1.2.1.1.5.3
upsBypassGroupEntryAn entry containing information applicable to a particular bypass input.
UpsBypassGroupEntry
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1
upsBypassGroupLineIndexThe bypass line identifier.ro
PositiveInteger
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.1
upsBypassGroupVoltageThe present bypass voltage.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.2
upsBypassGroupCurrentThe present bypass current.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.3
upsBypassGroupPowerThe present true power conveyed by the bypass.ro
NonNegativeInteger -- "Watts"
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.4
upsTestGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.6
upsTestBatteryTestSettingTimeThe object specify the test time for battery test.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.6.1
upsBatteryTestThis object specify the battery test type and initiate battery test. If battTestWithTime selected, the test time is refer to upsTestBatteryTestTime.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.6.2
upsTestBatteryTestResultThe results of the current or last UPS diagnostics test performed. The values for donePassed(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.ro
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.6.3
upsTestBatteryTestStartTimeThe value of the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestBatteryTestResult is noTestsInitiated(6), upsTestStartTime has the value 01/01/1970 00:00:00.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.6.4
upsTestBatteryTestElapsedTimeThe amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 00:00:00.00.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.6.5
upsBatteryTestScheduleTableTable which describes the schedule for automatically battery test.
SEQUENCE OF UpsBatteryTestScheduleEntry
.1.3.6.1.4.1.2468.1.2.1.1.6.6
upsBatteryTestScheduleEntry
UpsBatteryTestScheduleEntry
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1
upsBatteryTestScheduleIndexThe index of battery test scheduled.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.1
upsBatteryTestScheduleDayThe weekday on which the UPS should start battery test.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.2
upsBatteryTestScheduleTimeThe time that the battery test will be initiated in hh:mm format.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.3
upsBatteryTestScheduleTypeThe type of battery test.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.4
upsBatteryTestScheduleTestWithTimeThe battTestWithTime of battery test is supported or not.ro
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.5
upsBatteryTestScheduleSpecialDayThe special day that the battery test will be initiated in dd/mm/yyyy format.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.6
upsControlGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.7
upsControlUpsShutdownDelayThe delay in seconds the UPS remains on after being told to turn off.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.7.1
upsControlUpsSleepTimeThe time in minutes for the UPS to go to sleep when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 0 - 9999 minutes in one minute increments. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.7.2
upsControlUpsOnOffControlSetting this variable to control UPS output status. turnUpsOff(1) will set UPS turn off output after upsControlUpsShutdownDelay period expired. putUpsToSleep(2) will set UPS turn off output after upsControlUpsShutdownDelay period expired, UPS output will stay off with the period defined by upsControlUpsSleepTime, then turn output on. turnOnUpsOrCancelShutdown(3) can used to turn on UPS output, or cancel any shutdown process.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.7.3
upsControlShutdownParametersTableTable which describes the parametes for shutdown process when shutdown event occurs
SEQUENCE OF UpsControlShutdownParametersEntry
.1.3.6.1.4.1.2468.1.2.1.1.7.4
upsControlShutdownParametersEntry
UpsControlShutdownParametersEntry
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1
upsControlEventThe shutdown event identificationro
DisplayString SYNTAX INTEGER { acFail(1), batteryLow (2), upsOverload (3), upsOverTempeature (4), weeklySchedule (5), specialDaySchedule (6), emdTemperatureOverThreshold (7), emdAlarm1 (8), emdAlarm2 (9) }
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.1
upsControlEventStatusStatus of the corresponding shutdown Event. When set to disable(), shutdown process will not start when corresponding event occured.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.2
upsControlDelayThe Delay after the occurance of the curresponding shutdown event that USHA should issue shutdown request to connected clients. For WeeklyScheduledShutdown and SpecialScheduledShutdown, this is the time before the configured Shutdowntime when USHA will start sending the warning message to the connected clients. The value is in units of minutes.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.3
upsControlFirstWarningThe delay after the occurance of the curresponding shutdown event that the USHA will start sending the warning message to the connected clients. The value is in units of secondsrw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.4
upsControlWarningIntervalThe frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.5
upsControlWeeklyScheduleTableThe table to schedule shutting down the ups by weekly.
SEQUENCE OF UpsControlWeeklyScheduleEntry
.1.3.6.1.4.1.2468.1.2.1.1.7.5
upsControlWeeklyScheduleEntryThe entries for each day.
UpsControlWeeklyScheduleEntry
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1
upsControlWeeklyIndexThe index of scheduled events.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.1
upsControlWeeklyShutdownDayThe weekday on which the UPS should shut down.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.2
upsControlWeeklyShutdownTimeThe time that the process of shutting down the UPS will be initiated in hh:mm format.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.3
upsControlWeeklyRestartDayThe weekday on which the UPS should restartrw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.4
upsControlWeeklyRestartTimeThe time the UPS will restart in hh:mm format.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.5
upsControlSpecialScheduleTableThe table to schedule shutting down the ups.
SEQUENCE OF UpsControlSpecialScheduleEntry
.1.3.6.1.4.1.2468.1.2.1.1.7.6
upsControlSpecialScheduleEntryThe entries for each day.
UpsControlSpecialScheduleEntry
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1
upsControlSpecialIndexThe index of scheduled events.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.1
upsControlSpecialShutdownDayThe date on which the UPS should shut down in dd/mm/yyyy format.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.2
upsControlSpecialShutdownTimeThe time that the process of shutting down the UPS will be initiated in hh:mm formatrw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.3
upsControlSpecialRestartDayThe date on which the UPS should restart in dd/mm/yyyy formatrw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.4
upsControlSpecialRestartTimeThe time the UPS will restart in hh:mm format.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.5
upsConfigGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.8
upsConfigGroupInputVoltageThe magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.8.1
upsConfigGroupInputFreqThe nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.8.2
upsConfigGroupOutputVoltageThe magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.8.3
upsConfigGroupOutputFreqThe nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.8.4
upsConfigGroupOutputVAThe magnitude of the nominal Volt-Amp rating.ro
NonNegativeInteger -- "Volt-Amps"
.1.3.6.1.4.1.2468.1.2.1.1.8.5
upsConfigGroupOutputPowerThe magnitude of the nominal true power rating.ro
NonNegativeInteger -- "Watts"
.1.3.6.1.4.1.2468.1.2.1.1.8.6
upsConfigGroupOverTemperatureSetPointThe maximum temperature allowed before the UPS operation temperature is too high.rw
NonNegativeInteger
.1.3.6.1.4.1.2468.1.2.1.1.8.7
upsConfigGroupOverLoadSetPointThe maximum output load allowed before the load is too high for UPS operation.rw
NonNegativeInteger
.1.3.6.1.4.1.2468.1.2.1.1.8.8
upsClients
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.9
upsClientsConnectedNumThe count of clients which have resgistered for UPS shutdown control.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.9.1
upsDevicesTableThe devices powered by UPS and registered to USHA
SEQUENCE OF UpsDevicesEntry
.1.3.6.1.4.1.2468.1.2.1.1.9.2
upsDevicesEntryThe devices protected by USHA
UpsDevicesEntry
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1
indexOfDeviceThe index of the device that is plugged into the UPS.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.1
addrOfDeviceThe ip address of the device.ro
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.2
nameOfDeviceThe name/description of the device plugged into the UPS.ro
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.3
timeOfConnectionThe device registered to USHAro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.4
timeOfConnectionTimeThe device registered time to USHA.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.5
timeOfConnectionTimeoutThe device timeout counter. Unit: 10 secondsro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.6
agentConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.10
agentConfigIpaddressThe ip address that NMS can identify the managed devicerw
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.10.1
agentConfigGatewayThe default gateway that allow device managed through routersrw
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.10.2
agentConfigSubnetMaskInternet address subnet maskrw
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.10.3
agentConfigDateThe date in agent, format is (dd/mm/yyyy)rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.10.4
agentConfigTimeThe time in agent, format is (hh:mm:ss)rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.10.5
agentConfigPrimaryTimeServerThe primary time server is responsible for sending the correct time to the agent.rw
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.10.6
agentConfigSecondaryTimeServerThe secondary time server is responsible for sending the correct time to the agent.rw
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.10.7
agentConfigHistoryLogFrequencyThe frequency of the updation of the history log. The value is in secondsrw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.8
agentConfigExtHistoryLogFrequencyThe ups parameters are sampled at the rate governed by the mconfigHistroyLogFrequency. These sampled values are further conslidated over period of time which is determined by this object.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.9
agentConfigPollRateThe frequency that proxy agent polls the connected UPS in JBUS protocol. (unit : second)rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.10
agentConfigBaudRateThe serial port communication speed. only 9600 allowedro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.11
agentConfigDhcpStatueEnable or disable DHCP/BootP capabilityrw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.12
agentConfigTelnetStatueEnable or disable telnet accessrw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.13
agentConfigTftpStatueEnable or disable network upgrade capabilityrw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.14
agentConfigResetToDefaultReset all parameters of USHA to default valuerw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.15
agentConfigRestartRestart USHArw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.16
agentConfigClearAgentLogClear agent log datarw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.17
agentConfigClearEventLogClear event log datarw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.18
agentConfigClearExtHistoryLogClear extented history log datarw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.19
agentConfigClearHistoryLogClear history log datarw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.20
agentConfigTrapRetryCountThe count of repeat traps to send to NMS before trap acknowledge received.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.21
agentConfigTrapRetryTimeThe time between retry traps sned to NMS.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.22
agentConfigTrapAckSignatureThe signature of trap acknowledge.rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.23
agentConfigMibVersionThe version of MIB spec.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.24
agentConfigTrapsReceiversTableA list of managers to send traps to. The number of entries is given by the value of agentConfigNumTrapReceivers
SEQUENCE OF AgentConfigTrapsReceiversEntry
.1.3.6.1.4.1.2468.1.2.1.1.10.25
agentConfigTrapsReceiversEntryThe managers to send traps to.
AgentConfigTrapsReceiversEntry
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1
trapsIndexThe index to a trap receiver entry.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.1
trapsReceiverAddrThe IP address of the manager to send a trap to.rw
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.2
receiverCommunityStringThe community name to use in the trap when sent to the manager.rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.3
receiverNmsTypeThe trap group that NMS desired.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.4
receiverSeverityLevelThe severity level of traps to be received by this manager.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.5
receiverDescriptionDescription of trap receiversrw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.6
agentConfigAccessControlTableA list of managers which can access USHA with private community string.
SEQUENCE OF AgentConfigAccessControlEntry
.1.3.6.1.4.1.2468.1.2.1.1.10.26
agentConfigAccessControlEntryThe managers.
AgentConfigAccessControlEntry
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1
accessIndexThe index to a access control entry.ro
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.1
accessControlAddrThe IP address of the manager to access USHArw
IpAddress
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.2
accessCommunityStringThe community name to use in the manager when access USHArw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.3
accessControlModeAccess type, only read/Write access type can change parameter of USHArw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.4
agentConfigDefaultLanguageThe default languauge for browser, when set to auto(1) USHA will send page in the language depends on the request language of browser.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.10.27
emdStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.11
emdSatatusEmdTypeThe type of EMD plugged into the port.ro
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.11.1
emdSatatusTemperatureThe measurement of EMD temperature, in 0.1 degreero
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.11.2
emdSatatusHumidityThe measurement of EMD humidity, in 0.1 degreero
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.11.3
emdSatatusAlarm1The EMD alarm-1 statusro
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.11.4
emdSatatusAlarm2The EMD alarm-2 statusro
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.11.5
emdConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.12
usahEmdConfigEmdConfigEnable or disable to detect presence of EMDrw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.12.1
emdConfigEmdNameDescription of EMDrw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.12.2
emdConfigTemperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.12.3
emdConfigTempNameDescription of EMD temperature sensorrw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.12.3.1
emdConfigTempHighSetPointThe set point for high temperature warning, in degreesrw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.12.3.2
emdConfigTempHighStatusTo enable/disable high set point check with emd temperature.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.12.3.3
emdConfigTempLowSetPointThe set point for low temperature warning, in degreesrw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.12.3.4
emdConfigTempLowStatusTo enable/disable low set point check with emd temperature.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.12.3.5
emdConfigTempOffsetThe offset to calibrate temperature of EMD, in degreesrw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.12.3.6
emdConfigHumidity
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.12.4
emdConfigHumidityNameDescription of EMD humidity sensorrw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.12.4.1
emdConfigHumidityHighSetPointThe set point for high humidity warning, in %rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.12.4.2
emdConfigHumidityLowStatusTo enable/disable high set point check with emd humidity.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.12.4.3
emdConfigHumidityLowSetPointThe set point for low humidity warning, in %rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.12.4.4
emdConfigHumidityHighStatusTo enable/disable low set point check with emd humidity.rw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.12.4.5
emdConfigHumidityOffsetThe offset to calibrate humidity of EMD, in %rw
INTEGER
.1.3.6.1.4.1.2468.1.2.1.1.12.4.6
emdConfigAlarm1
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.12.5
emdConfigAlarm1NameDescription of EMD alarm-1rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.12.5.1
emdConfigAlarm1TypeThe alarm-1 operation typerw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.12.5.2
emdConfigAlarm2
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.1.12.6
emdConfigAlarm2NameDescription of EMD alarm-2rw
DisplayString
.1.3.6.1.4.1.2468.1.2.1.1.12.6.1
emdConfigAlarm2TypeThe alarm-1 operation typerw
Enumeration
.1.3.6.1.4.1.2468.1.2.1.1.12.6.2
upsTrapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2468.1.2.1.2
ushaPowerRestoredINFORMATION: Utility power has been restore.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.1
ushaPowerFailWARNING: Utility power not available.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.2
ushaReturnFromLowBatteryINFORMATION: The UPS has return from a low battery condition.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.3
ushaLowBatterySEVERE: The UPS batteries are low and will soon be exhausted.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.4
ushaUpsOkINFORMATION: The ups is working fine.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.5
ushaUpsFailedSEVERE: The ups is not working fine.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.6
ushaUpsNotOnBatteryINFORMATION: The UPS is not on battery power.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.7
ushaUpsOnBatteryWARNING: The UPS has switched to battery backup power.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.8
ushaTestOverINFORMATION: The testing of UPS is completed.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.9
ushaTestInProgressINFORMATION: The testing is going on ups.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.10
ushaBypassOnINFORMATION: The UPS has enabled bypass.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.11
ushaUpsOnlineINFORMATION: The UPS is not on Bypass and return to normal status.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.12
ushaCommunicationLostSEVERE: Communication to the UPS has been lost.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.13
ushaCommunicationEstablishedINFORMATION: Communication with the UPS has been established.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.14
ushaUpsGoingDownWARNING: The ups has been given shutdown command.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.15
ushaUpsTurnedOffINFORMATION: UPS turn off.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.16
ushaUpsSleepingINFORMATION: UPS has entered sleep mode.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.17
ushaUpsWokeUpINFORMATION: The UPS woke up from sleep mode.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.18
ushaUpsRebootedINFORMATION: The UPS is reboot.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.19
ushaUpsShutdownCancelledINFORMATION: The UPS shutdown process had been cancelled.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.20
ushaUpsNotOverTemperatureINFORMATION: The UPS internal temperature return to normal.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.21
ushaUpsOverTemperatureSEVERE: The UPS temperature is too high.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.22
ushaUpsNotOverLoadINFORMATION: The UPS load return from overload.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.23
ushaUpsOverLoadSEVERE: The UPS is overload.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.24
ushaUpsModuleInsertedWARNING: UPS Battery Module plug-in.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.25
ushaUpsModuleRemovedWARNING: UPS Battery Module unplug.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.26
emdTemperatureNotHighINFORMATION: EMD Temperature not over high Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.27
emdTemperatureTooHighWARNING: EMD Temperature over high Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.28
emdTemperatureNotLowINFORMATION: EMD Temperature not under low Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.29
emdTemperatureTooLowWARNING: EMD Temperature under low Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.30
emdHumidityNotHighINFORMATION: EMD Humidity not over high Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.31
emdHumidityTooHighWARNING: EMD Humidity over high Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.32
emdHumidityNotLowINFORMATION: EMD Humidity not under low Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.33
emdHumidityTooLowWARNING: EMD Humidity under low Set point.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.34
emdAlarm1NormalINFORMATION: EMD Alarm-1 not active.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.35
emdAlarm1ActiveWARNING: EMD Alarm-1 activated.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.36
emdAlarm2NormalINFORMATION: EMD Alarm-2 not active.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.37
emdAlarm2ActiveWARNING: EMD Alarm-2 activated.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.38
ushaUpsInternalwarningWARNING: Internal warning.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.39
ushaUpsReturnFromInternalwarningINFORMATION: Return from Internal warning.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.40
ushaUpsEPOActiveWARNING: EPO Active.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.41
ushaUpsReturnFromEPOActiveINFORMATION: Return from EPO Active.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.42
ushaUpsModuleUnlockWARNING: Module Unlock.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.43
ushaUpsReturnFromModuleUnlockINFORMATION: Return from Module Unlock.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.44
ushaUpsMain1NeutrallossWARNING: Main 1 Neutral loss.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.45
ushaUpsReturnFromMain1NeutrallossINFORMATION: Return from Main 1 Neutral loss.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.46
ushaUpsMain1phaseerrorWARNING: Main 1 phase error.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.47
ushaUpsReturnFromMain1phaseerrorINFORMATION: Return from Main 1 phase error.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.48
ushaUpsSitefaultWARNING: Site fault.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.49
ushaUpsReturnFromSitefaultINFORMATION: Return from Site fault.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.50
ushaUpsBypassAbnormalWARNING: Bypass Abnormal.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.51
ushaUpsReturnFromBypassAbnormalINFORMATION: Return from Bypass Abnormal.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.52
ushaUpsBypassPhaseErrorWARNING: Bypass Phase Error.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.53
ushaUpsReturnFromBypassPhaseErrorINFORMATION: Return from Bypass Phase Error.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.54
ushaUpsBatteryOpenWARNING: Battery Open.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.55
ushaUpsReturnFromBatteryOpenINFORMATION: Return from Battery Open.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.56
ushaUpsBatteryOverChargeWARNING: Battery Over Charge.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.57
ushaUpsReturnFromBatteryOverChargeINFORMATION: Return from Battery Over Charge.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.58
ushaUpsBatteryReverseWARNING: Battery Reverse.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.59
ushaUpsReturnFromBatteryReverseINFORMATION: Return from Battery Reverse.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.60
ushaUpsOverloadforewarningWARNING: Overload forewarning.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.61
ushaUpsReturnFromOverloadforewarningINFORMATION: Return from Overload forewarning.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.62
ushaUpsOverloadWarningWARNING: Overload Warning.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.63
ushaUpsReturnFromOverloadWarningINFORMATION: Return from Overload Warning.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.64
ushaUpsFanLockWARNING: Fan Lock.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.65
ushaUpsReturnFromFanLockINFORMATION: Return from Fan Lock.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.66
ushaUpsMaintaincoverisopenWARNING: Maintain cover is open.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.67
ushaUpsReturnFromMaintaincoverisopenINFORMATION: Return from Maintain cover is open.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.68
ushaUpsChargerfaultWARNING: Charger fault.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.69
ushaUpsReturnFromChargerfaultINFORMATION: Return from Charger fault.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.70
ushaUpsModulelocationerrorWARNING: Module location error.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.71
ushaUpsReturnFromModulelocationerrorINFORMATION: Return from Module location error.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.72
ushaUpsTurnonabnormalWARNING: Turn on abnormal.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.73
ushaUpsReturnFromTurnonabnormalINFORMATION: Return from Turn on abnormal.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.74
ushaUpsRedundancylossWARNING: Redundancy loss.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.75
ushaUpsReturnFromRedundancylossINFORMATION: Return from Redundancy loss.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.76
ushaUpsHotSwapActivedWARNING: Hot Swap Actived.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.77
ushaUpsReturnFromHotSwapActivedINFORMATION: Return from Hot Swap Actived.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.78
ushaUpsBatteryInformWARNING: Battery Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.79
ushaUpsReturnFromBatteryInformINFORMATION: Return from Battery Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.80
ushaUpsInspectionInformWARNING: Inspection Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.81
ushaUpsReturnFromInspectionInformINFORMATION: Return from Inspection Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.82
ushaUpsGuaranteeInformWARNING: Guarantee Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.83
ushaUpsReturnFromGuaranteeInformINFORMATION: Return from Guarantee Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.84
ushaUpsTemperatureLowWARNING: Temperature Low.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.85
ushaUpsReturnFromTemperatureLowINFORMATION: Return from Temperature Low.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.86
ushaUpsTemperatureHighWARNING: Temperature High.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.87
ushaUpsReturnFromTemperatureHighINFORMATION: Return from Temperature High.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.88
ushaUpsBatteryOverTemperatureWARNING: Battery Over Temperature.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.89
ushaUpsReturnFromBatteryOverTemperatureINFORMATION: Return from Battery Over Temperature.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.90
ushaUpsFanMaintainInformWARNING: Fan Maintain Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.91
ushaUpsReturnFromFanMaintainInformINFORMATION: Return from Fan Maintain Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.92
ushaUpsBusCapacitanceMaintainInformWARNING: Bus Capacitance Maintain Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.93
ushaUpsReturnFromBusCapacitanceMaintainInformINFORMATION: Return from Bus Capacitance Maintain Inform.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.94
ushaUpsSystemOverCapacityWARNING: System Over Capacity.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.95
ushaUpsReturnFromSystemOverCapacityINFORMATION: Return from System Over Capacity.
TRAP-TYPE
.1.3.6.1.4.1.2468.1.2.1.2.0.96
USHA-MIB - SNMP MIB Reference | MIBs Explorer